5. S T A N L E Y P. A S H B U I L D I N G
GLASS TYPES:
NOTES:
WINDOW FRAME TYPES:
BRICK:
NTS
KEYPLAN
A200E
6
A200E
2
A200E
3
A200E
4
A200E
5
A200E
1
OCC
SCALE
SHEET TITLE
APPROVED
APPROVED
FOR CONSTR
CHECKED
DRAWN
ISSUED
PROJECT #
DRAWING NO
AUBURN HILLS
6. DIVISION 3
3.31 CAST-IN-PLACE CONCRETE RE: STRUCTURAL
3.32 VAPOR RETARDER
3.33 ARCHITECTURAL CONCRETE
3.34 BRICK LEDGE RE: STRUCTURAL
DIVISION 4
4.20 FACE BRICK
4.21 CONCRETE MASONRY UNIT (unit thickness)
4.22 2" CAVITY WALL INSULATION
4.23 OPEN HEAD WEEP AT 2'-0" O.C.
4.24 CAVITY DRAINAGE MATERIAL
4.25 EMBEDDED FLASHING RE: 27/A615E FOR SS DRIP EDGE, TYP
4.26 COMPRESSIBLE FILLER
4.27 GROUT SOLID
4.28 GLASS UNIT MASONRY
4.32 MASONRY ANCHOR AT 1'-4" OC
4.34 TOP OF WALL ANCHOR AT 4'-0" OC
4.35 BOND BEAM RE: STRUCTURAL
4.36 MASONRY JOINT REINFORCEMENT / TIE
DIVISION 5
5.12 STRUCTURAL STEEL RE: STRUCTURAL
5.21 STEEL JOISTS RE: STRUCTURAL
5.31 METAL DECK RE: STRUCTURAL
5.41 COLD-FORMED METAL FRAMING (depth)
5.42 VERTICAL DEFLECTION CLIP
5.44 ATTACH FRAMING TO STRUCTURE
5.51 STEEL ANGLE LINTEL RE: STRUCTURAL
5.52 MISC STEEL (shape / size)
5.53 PIPE AND TUBE RAILINGS
DIVISION 6
6.11 FRT WOOD BLOCKING (thickness other than 2x)
6.13 FRT PLYWOOD (panel thickness)
6.16 GLASS-MAT GYPSUM SHEATHING
6.41 SOLID SURFACE MATRERIAL
DIVISION 7
7.12 WATERPROOFING SYSTEM
7.14 INSULATION DRAINAGE PANEL
7.21 2" X 2'-0" X CONT PERIMETER INSULATION
7.22 BATT INSULATION (thickness)
7.24 RIGID INSULATION (thickness other than 2")
7.25 SPRAY POLYURETHANE FOAM INSULATION
7.27 AIR / VAPOR BARRIER
7.28 AIR / VAPOR BARRIER TRANSITION
7.41 METAL SOFFIT / FASIA W/ FLUSH SEAMS RE: 16/A615E
7.42 VERTICAL SEAM METAL PANEL SIDING SYSTEM
7.51 SINGLE-PLY ROOF SYSTEM
7.52 ROOF SYSTEM FLASHING
7.53 COMPRESSIBLE TUBE
7.54 ROOF INSULATION (see A105E for thickness)
7.61 COUNTERFLASHING AND RECEIVER RE: 23,24,26 / A615E
7.65 PREFINISHED METAL COPING
7.66 CONTINUOUS CLIP
7.81 SPRAY APPLIED FIREPROOFING (1 hour rating)
7.85 FIRE RESISTIVE JOINT SYSTEM
7.91 SEALANT - ALL AROUND
7.92 BACKER ROD AND SEALANT
DIVISION 8
8.11 HOLLOW METAL DOOR AND FRAME RE: DOOR SCHEDULE
8.14 WOOD DOOR RE: DOOR SCHEDULE
8.32 SLIDING ALUMINUM FRAMED GLASS DOOR
8.41 STOREFRONT SYSTEM
8.43 ENTRANCE DOOR
8.44 CURTAIN WALL SYSTEM
8.45 BRAKE METAL TRIM
8.46 CURTAIN WALL ATTACHING CLIP
8.71 THRESHOLD
8.81 INSULATING GLASS RE: ELEVATIONS FOR TYPE U.N.O.
8.91 LOUVER
8.92 LOUVER SILL FLASHING
DIVISION 9
9.22 NON-LOAD BEARING STEEL STUDS (depth)
9.25 GYPSUM BOARD (thickness other than 5/8")
9.26 L-BEAD
9.27 F BEAD, 1/2" REVEAL
9.51 ACOUSTIC PANEL CEILING
DIVISION 12
12.24
12.48 FLOOR MAT
DIVISION 23 (REFER TO MECHANICAL)
31.23 • •• • • • •• • • • •• •• • • • • • • •• •• •• • • • • • • •• • • •• • • •• •• •• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
23.01 RADIATOR
DIVISIONS 31, 32, 33 (REFER TO CIVIL)
31.21 FINISH GRADE
32.13 CONCRETE PAVEMENT
32.14 PAVEMENT ISOLATION JOINT AND SEALANT
EXTERIOR ENVELOPE NOTES:
1. FOUNDATIONS AND FOOTINGS SHOWN ARE SCHEMATIC. REFER TO
STRUCTURAL DOCUMENTS FOR REQUIREMENTS.
2. REFER TO STRUCTURAL DOCUMENTS FOR VERTICAL
REINFORCING IN CONCRETE MASONRY WALLS.
3. INTERIOR FINISHES ARE NOT SHOWN. REFER TO
ROOM FINISH SCHEDULE.
4. EJ = EXPANSION JOINT. REFER TO DETAIL 13 / A601E
5. MAINTAIN AIR/VAPOR BARRIER CONTINUITY THROUGHOUT PROJECT. SEAL
PERIMETER, JOINTS BETWEEN SUBSTRATES, PENETRATIONS AND PUNCTURES.
6. REFER TO ELEVATIONS FOR GLAZING AND
FRAME TYPES.
7. REFER TO REFLECTED CEILING PLANS FOR CEILING HEIGHTS.
8. FILL VOIDS AROUND STOREFRONT AND CURTAIN WALL PERIMETERS WITH
7.22(FILL) INSULATION.
9. PAINT EXPOSED FERROUS METAL.
6.44 PLASTIC LAM. OVER PART. BD.
9.21 SHAFTWALL ASSEMBLY RE: A005E
9.30 CERAMIC TILE (RE: finish schedule)
9.41 ACOUSTIC BATT INSULATION
9.52 CEILING SUSPENSION SYSTEM
DIVISION 10
10.11 VISUAL DISPLAY SURFACE
10.14 SIGNAGE
10.17 TELEPHONE
10.21 TOILET COMPARTMENT
10.28 TOILET ACCESSORIES RE: A400E
ROLLER SHADE
12.32 CASEWORK
DIVISION 14
14.24 ELEVATOR
DIVISION 22
22.40 PLUMBING FIXTURE
22.47 WATER COOLERS
23.71 DIFFUSERS, REGISTERS, AND GRILLES
DIVISION 26
26.51 INTERIOR LIGHTING
4.72 CAST STONE MASONRY
5.54 METAL STAIRS
5.70 DECORATIVE METAL RAILINGS
7.43 FLAT PANEL METAL SIDING SIDING SYSTEM
7.44 CONTINUOUS CLEAT
7.45 FIXED OR SLIDING CLEAT RE: 6/A615E
8.93 INSECT SCREEN
9.28 V-SHAPED CONTROL JOINT
9.29 3 PIECE EXTRUDED ALUMINUM GYPSUM BOARD EXPANSION JOINT
10. EXTERIOR WALL LINTELS AND BRICK LEDGES TO BE GALVANIZED.
11. STEEL TO RECEIVE SPRAY APPLIED FIREPROOFING TO BE UNPRIMED.
KEY NOTES
DIVISION NUMBERS REFER TO CSI MASTER FORMAT
31.24 FILTER FABRIC OVER GRAVEL DRAINAGE BED
12. REFER TO STRUCTURAL FOR SUB-SLAB PREPARATION INCLUDING DRAINAGE
COURSE, UNDERDRAINS AND VAPOR RETARDER
7.95 BUILDING EXPANSION JOINT
7.29 BUILDING WRAP AIR / MOISTURE BARRIER
4.73 CAST STONE ANCHOR @ HEAD JOINT, EXP ANCHOR TO CMU
4.37 1
2••• •• • • • • • •• • •• • • • • • •• •• • •• •••••••••••••••••••••••••••••
7.30 DIRECT APPLIED FINISH SYSTEM
7.31 EXTERIOR INSULATED FINISH SYSTEM
5.43 COLD-FORMED METAL FURRING, 2" ZEE SHAPE @ 24" oc
7.26 VAPOR RETARDER
8.47 METAL ANCHOR STRAP
A101E
1
A101E
2
A101E
3
A101E
4 A101E
5
A101E
6
A101E
13
A103E
12
A103E
11
A103E
10
A103E
14
A103E
15
A103E
16
A103E
21
A101E
8
A101E
7
A103E
17
SCALE
SHEET TITLE
APPROVED
APPROVED
FOR CONSTR
CHECKED
DRAWN
ISSUED
DSA Architects - A Member of SHW Group, LLP• • • • • •• • • •• •• • • • ••••••••••••••••••
PROJECT #
DRAWING NO
ALEX BACON
A-300
10. Project: Design construction documents for a two story, two bath, three bedroom
home with unfinished basement and two car garage.
11.
12.
13.
14.
15. Scope of Work:Convert freight loading area into lounge and male/
female bathrooms. Convert a single door bus garage into a two
door bus garage. Install electrical diesel engine warming stations
for every bus parking space. Replace catch basin storm drains in
far north parking area.
Photo's from the Ann Arbor News Website: http://
www.annarbor.com/news/ypsilanti/ypsilanti-willow-run-bus-
garage-renovations-on-track-for-completion-by-1st-day-of-school/
19. Southgate Police Department
14710 Reaume Pkwy
Southgate, MI 48195
Scope of Work: The project will keep the Southgate police department in
compliance with ADA handicap walkways. The work includes construction
of ADA compliant concrete sidewalks, walk ways, and maintain ADA
compliant grading while insuring proper drainage.