Case Study
Hot Levellers Control Pulpit
Process Details: Production control facility for a plate mill operated by a world leading steel-maker.
Scope of Work: To design, manufacture, deliver and install the required facility, this being of approximate overall
sizes 5.2m long x 3.6m wide x 2.9m high.
Design Considerations: -
• Structural steel skeleton complete with integral lattice frame floor (fully boarded). Walls and roof over-clad
with bespoke manufactured panelling.
• Panel inner fascias in perforated steel for maximum acoustic absorption, and all powder coated for durability,
longevity, ease of cleaning etc.
• The overall heavy duty construction being suitable for operation in the noisy, dirty & dusty conditions
associated with this heavy industrial process, and fit for purpose in providing a safe working environment for
operations and maintenance personnel.
• Single man access door for personnel entry / egress and emergency exit.
• Acoustically insulated vision panels (manufactured in tinted, heat reflective safety glass & inclined to prevent
the build-up of dust & dirt on the panes) providing operational personnel with a panoramic overview of the mill
and the `Levelling' process, whilst offering protection from hot plate glare.
• The unit provides the housed computer & visual display equipment with suitable protection against the
harmful effects of condensation, corrosion etc.
• Monitor hanging bracket system facilitates the mounting of the required visual display units at high level.
• Industrial type air conditioning unit (ducting, ceiling mounted diffusers & air return grilles etc. all inclusive)
ensures total comfort of personnel and the satisfactory operation of the installed electrical equipment.
• Turnkey package included the provision of suspended ceilings, modular & emergency lighting, mains power &
data transfer services, finished floor overlays etc.
• Rigid manufacturing programme and a limited installation schedule to coincide with the end users two-week
summer shut-down period.
Acoustic Performance: The office construction provided a 30dB reduction from factory ambient noise levels,
allowing personnel to effectively communicate in a stress-free, comfortable environment.
Acoustic Applications is the trading name of Xtron Systems Limited
Unit 8, Caldervale Road, Horbury Junction Industrial Estate, Wakefield, West Yorkshire, WF4 5ER.
Telephone No. +44 (0) 1924 26 21 65 Facsimile No. +44 (0) 1924 26 48 17
England & Wales Company Registration No. 06986821 - VAT Registration No. GB 981 1986 80

Más contenido relacionado

Más de Christian Senior

C4494 Case Study - Caster Control Complex
C4494 Case Study - Caster Control ComplexC4494 Case Study - Caster Control Complex
C4494 Case Study - Caster Control ComplexChristian Senior
 
C4359 Case Study - Noise Barrier Screening
C4359 Case Study - Noise Barrier ScreeningC4359 Case Study - Noise Barrier Screening
C4359 Case Study - Noise Barrier ScreeningChristian Senior
 
C4905 Case Study - Welding Control Pulpit
C4905 Case Study - Welding Control PulpitC4905 Case Study - Welding Control Pulpit
C4905 Case Study - Welding Control PulpitChristian Senior
 
C4706 Case Study - Acoustic Screen with Chevron Louvres
C4706 Case Study - Acoustic Screen with Chevron LouvresC4706 Case Study - Acoustic Screen with Chevron Louvres
C4706 Case Study - Acoustic Screen with Chevron LouvresChristian Senior
 
C5169 Case Study - Acoustic enclosure for a Horizontal Balancing Machine
C5169 Case Study - Acoustic enclosure for a Horizontal Balancing MachineC5169 Case Study - Acoustic enclosure for a Horizontal Balancing Machine
C5169 Case Study - Acoustic enclosure for a Horizontal Balancing MachineChristian Senior
 
C4917 Case Study - Acoustic enclosures for Plasma Cutting Machines
C4917 Case Study - Acoustic enclosures for Plasma Cutting MachinesC4917 Case Study - Acoustic enclosures for Plasma Cutting Machines
C4917 Case Study - Acoustic enclosures for Plasma Cutting MachinesChristian Senior
 

Más de Christian Senior (6)

C4494 Case Study - Caster Control Complex
C4494 Case Study - Caster Control ComplexC4494 Case Study - Caster Control Complex
C4494 Case Study - Caster Control Complex
 
C4359 Case Study - Noise Barrier Screening
C4359 Case Study - Noise Barrier ScreeningC4359 Case Study - Noise Barrier Screening
C4359 Case Study - Noise Barrier Screening
 
C4905 Case Study - Welding Control Pulpit
C4905 Case Study - Welding Control PulpitC4905 Case Study - Welding Control Pulpit
C4905 Case Study - Welding Control Pulpit
 
C4706 Case Study - Acoustic Screen with Chevron Louvres
C4706 Case Study - Acoustic Screen with Chevron LouvresC4706 Case Study - Acoustic Screen with Chevron Louvres
C4706 Case Study - Acoustic Screen with Chevron Louvres
 
C5169 Case Study - Acoustic enclosure for a Horizontal Balancing Machine
C5169 Case Study - Acoustic enclosure for a Horizontal Balancing MachineC5169 Case Study - Acoustic enclosure for a Horizontal Balancing Machine
C5169 Case Study - Acoustic enclosure for a Horizontal Balancing Machine
 
C4917 Case Study - Acoustic enclosures for Plasma Cutting Machines
C4917 Case Study - Acoustic enclosures for Plasma Cutting MachinesC4917 Case Study - Acoustic enclosures for Plasma Cutting Machines
C4917 Case Study - Acoustic enclosures for Plasma Cutting Machines
 

C4293 Case Study - Plate Mill Hot Levellers Control Pulpit

  • 1. Contact us for your industrial noise solutions. +44 (0) 1924 26 21 65 sales@acousticapplications.co.uk Case Study Hot Levellers Control Pulpit Process Details: Production control facility for a plate mill operated by a world leading steel-maker. Scope of Work: To design, manufacture, deliver and install the required facility, this being of approximate overall sizes 5.2m long x 3.6m wide x 2.9m high. Design Considerations: - • Structural steel skeleton complete with integral lattice frame floor (fully boarded). Walls and roof over-clad with bespoke manufactured panelling. • Panel inner fascias in perforated steel for maximum acoustic absorption, and all powder coated for durability, longevity, ease of cleaning etc. • The overall heavy duty construction being suitable for operation in the noisy, dirty & dusty conditions associated with this heavy industrial process, and fit for purpose in providing a safe working environment for operations and maintenance personnel. • Single man access door for personnel entry / egress and emergency exit. • Acoustically insulated vision panels (manufactured in tinted, heat reflective safety glass & inclined to prevent the build-up of dust & dirt on the panes) providing operational personnel with a panoramic overview of the mill and the `Levelling' process, whilst offering protection from hot plate glare. • The unit provides the housed computer & visual display equipment with suitable protection against the harmful effects of condensation, corrosion etc. • Monitor hanging bracket system facilitates the mounting of the required visual display units at high level. • Industrial type air conditioning unit (ducting, ceiling mounted diffusers & air return grilles etc. all inclusive) ensures total comfort of personnel and the satisfactory operation of the installed electrical equipment. • Turnkey package included the provision of suspended ceilings, modular & emergency lighting, mains power & data transfer services, finished floor overlays etc. • Rigid manufacturing programme and a limited installation schedule to coincide with the end users two-week summer shut-down period. Acoustic Performance: The office construction provided a 30dB reduction from factory ambient noise levels, allowing personnel to effectively communicate in a stress-free, comfortable environment. Acoustic Applications is the trading name of Xtron Systems Limited Unit 8, Caldervale Road, Horbury Junction Industrial Estate, Wakefield, West Yorkshire, WF4 5ER. Telephone No. +44 (0) 1924 26 21 65 Facsimile No. +44 (0) 1924 26 48 17 England & Wales Company Registration No. 06986821 - VAT Registration No. GB 981 1986 80