1. B. NARENDRAN
Email: beekaynaren@gmail.com
Permanent Address
1/519A Gandhinagar,
Konamoolai,
Sathyamangalam, Erode,Tamilnadu
India
Pin-638402
Mobile No: 91-09443237461
91-08056007461
Personal Data
DOB : 04st
October 1989
Nationality : Indian
Marital Status : Single
Passport No : M7133885
Date of Issue : 11/03/2015
Date of Expiry : 10/03/2025
Languages Known
English Read, Speak, Write
Tamil Read, Speak, Write
Hindi Speak
Career Objective
To apply my technical skills and knowledge to full use in the place of
my work and to improve myself and the company through constant
learning and hard work.
Academic Details
Bachelor of Engineering in Electrical and Electronics
Graduated March 2011
ANNA UNIVERSITY
(DMI College Of Engineering, Palanchur, Nazerathpet Post,
Sriperumpudur Taluk, Pin code:- 600123)
Summary of Experience
PRESENT EMPLOYER
Organization : Voltech Engineers. Pvt. Ltd.
Designation : Sr. Testing and Commissioning Engineer &
Protection Engineer
Period :12nd
March 2012 To Till date(3yrs 2months)
Computer Proficiency
SIEMENS Relay Configuration Software,
AREVA Relay Configuration Software,
ABB Relay Configuration Software,
GE Relay Configuration Software
SEPOM Relay Configuration Software.
SEL Relay Configuration Software.
Testing of relays with OMICRON and DOBEL kit.
2. EXPERIENCE DETAILS
1. TESTING OF ELECTRICAL EQUIPMENTS:
1. Power Transformer up to 240 MVA.
2. 220KV, 132KV, 33KV, 11KV Sf6, VCB, Breakers, Isolators.
3. Commissioning of motors up to 1400kw Make: ABB.BHEL
4. Configuration and testing of AREVA, ABB, SIEMENS, GE, SEL and SEPOM relays.
5. Microprocessor Relays and Static relays (Over current/Earth fault relays, all auxiliary Relays,
Differential relays, Distance Relays and Neutral Displacement relays.)
6. Current Transformers (Insulation resistance test, Winding resistance Measurement, Polarity, Ratio
test, Sensitivity test, Stability test, Knee Point Voltage Test.)
7. Potential Transformer (Insulation resistance test, Winding resistance Measurement, Polarity,
Ratio Test.)
8. Power transformer (Insulation resistance test, Winding resistance Measurement, Magnetic
balance, Magnetizing current, vector group, short circuit test.)
9. Energy meters, Transducers, Voltmeters and Ammeters.
10. Hi Pot for Bus bars, HT & LT Cables.
2.PROJECTS HANDLED:
1. Testing and commissioning: 220kv,132kv switchyard, 11kV and 415V switchgear panel.
CUSTOMER: TATA STEEL Ltd-KALINGANAGAR,-JOJPUR, ORISSA
INDIA.
CLIENT : TATA POWER.
DURATION: 20th
August 2012 to 29th
December 2012
2. Testing and commissioning: 1*370MW POWER PLANT 415V switchgear panel.
CUSTOMER: BOKARO STEEL PLANT (SAIL)-BOKARO,-JHARKHAND,
INDIA.
CLIENT : ALSTOM
DURATION: 2th
January 2013 to 28th
Febuary 2012
3. Configuration and testing of relays AREVA (P122,P220,P921)
CUSTOMER: TATA IRON AND STEEL CO ltd, JAMSHEDPUR-JHARKHAND, INDIA .
CLIENT : VOLTAS Ltd.
4. Configuration and testing of relays AREVA (P143,P122,P220,P141,P632,P921,P127)
CUSTOMER: USHA MARTIN Ltd, JAMSHEDPUR- JHARKHAND, INDIA.
CLIENT: DINESH ELECTRICALS Ltd.
3. 5. Configuration and testing of relays AREVA (P632, P543, P141, P243.)
CUSTOMER: SAIL- Rourkela Steel Plant (RSP), located in Rourkela, Odisha, INDIA.
6. Configuration and testing of relays ABB (REM 545) and AREVA (P241)
CUSTOMER: THARANI SUGARS, KALLAKURICHI, INDIA.
.
7. Configuration and testing of relays AREVA (P443)
CUSTOMER: Andhra Pradesh State Electricity Board-MAKHTAL, ANDRA PRADESH,
INDIA.
.
8. Configuration and testing of relays AREVA (P143,P243,P241,P141,P632,P921)
CUSTOMER: JP-NIGREE,MADHYA PRADESH, INDIA.
CLIENT: STIGMA Pvt Ltd.
9. Configuration and testing of relays SEL (751A,787,710)
CUSTOMER: Uttar Pradesh Power Corporation Limited(UPPCL)-SINGROLI,
UTTAR PRADESH, INDIA.
CLIENT: STIGMA Pvt Ltd.
10. Configuration and testing of relays ABB REM(543)
CUSTOMER: 36MW SREE DATA POWER PLANT,SOLAPUR-MAHARASTRA
CLIENT: THERMAX India Ltd.
11. Configuration and testing of relays AREVA P143 P122 P220,GE 650,GE 339 GE 350
CUSTOMER: 2*660MW THERMAL POWER PLANT(GMR) TILDA,RAIPUR-
CHHATTISGARH
CLIENT: CHANG WOON India Ltd.
12. Configuration and testing of relays SIEMENS 7SA522 7UT512 ,EASUN RAY ROLE-2TJM11
CUSTOMER: 132KV/33KV SUB STATION SONBARSHA ,BIHAR
CLIENT: TECHNO/PGCIL india Ltd.
13. Configuration and testing of relays ABB (REF 615) (REM 615)
CUSTOMER: RAJASTHAN RAJYA VIDYUT UTPADAM NIGAM Ltd- CHABRA,INDIA.
CLIENT : ABB Ltd.
4. 14. Configuration and testing of relays SIEMENS 7SJ610,7SD610,7UT512
CUSTOMER: CHENNAI METRO RAIL PROJECT- KOYAMBADU, CHENNAI ,INDIA.
CLIENT : SIEMENS India Ltd.
15. Configuration and testing of relays ABB (REF 615) (REM 615) (RET615) (SPAJ140C)
CUSTOMER: 4*360 MW RKM POWER GEN – KORBA, CHHATTISGARH, INDIA.
CLIENT : RKM POWER GEN India
16. Configuration and testing of relays AREVA (P632) (P120) (P521) (P139) (P122) (P127) (P922)
CUSTOMER: 132KV/33KV SUB STATION BORL CPP PLANT, BINA, M.P,INDIA
CLIENT : SCHEIDER ELECTRIC Ltd.
PRESENT PROJECT:
1. Configuration and testing of relays: ABB REG 670,RET 670 AREVA (P632) (P120) (P521)
(P139) (P122) (P127) (P922)
CUSTOMER: 3*33MW BORL CPP PLANT, BINA, MADHYA PRADESH ,INDIA
CLIENT : TATA POWER Ltd
Academic Project
Design of Inter cell transformers .
• Description: A Conventional fly back converter is revamped using an inter- cell transformer ,unlike a
normal transformer Construction of inter cell transformer varies by usage of coupled inductors where
compactness , overall efficiency and cost effectiveness are dramatically improved.
Skill Sets
Good knowledge in Testing and Commissioning.
Good team player, Fast learner and a hard worker.
Able to do as a commissioning coordinator.
Self Confident, Motivated
Creative thinking
Leadership and Interpersonal skills
Place: sincerely yours