Más contenido relacionado La actualidad más candente (19) Similar a Mass flow processor datasheet v4 (20) Mass flow processor datasheet v41. Density & Mass Flow Processor
SCIAM offers a processor which is designed to take the 4 – 20 mA outputs from a DM3
Transmitter and flow signal from a volumetric flow meter. SCIAM recommends only volumetric
flow meters known to have an acceptably low signal to media noise ratio. Magnetic flow
meters with correct liners and grounding, suitable for mining,
dredging and similar slurries are recommended.
The processor accurately multiplies the density and volumetric
flow signals to provide a 4 – 20 mA output proportional to mass
flow rate. It is then programmable using 4 push buttons on the
front panel to provide a digital display, record and outputs for
wet or dry totalized mass flow and mass flow rate, wet density
or wet sg, or % dry solids.
The processor also has the capability to log data to an internal
memory, removable memory and connects to ‘Historian’
software via Ethernet. Settings for alarms and alerts are also
programmable using the processor.
Processor Technical Data
Display: 3.5” TFT colour (320 pixels wide x 240 pixels high)
User Interface: 4 tactile buttons for page, scroll, lower and raise
Panel Size: ¼ DIN (96mm x 96mm)
IP rating: IP65
PV Accuracy: Better than 0.1% of reading
Alarms: 2 per channel
Alarm Types: Absolute High/Low, Deviation High/Low, Deviation Band, Rate of Change
USB port: 1 USB 1.1 port at rear
Memory for Data Storage: 50MB
Recording Formats: UHH (Eurotherm proprietary secure, check summed file system) or CSV
Recording Destinations: Internal Flash, FTP Server, or USB memory stick (up to 8GB)
Recording Speed: 8Hz
Trend Speed: 1Hz
Removable Media: USB memory stick (up to 8GB)
Virtual Channels: 14 Standard, plus 16 optional (Maths/Totalisers/Counters)
Maths Types: Add, Subtract, Multiply, Divide, Group Min/Max, Channel Min/Max,
Channel average, Configuration revision, Modbus Input
Recording Groups: One
Toolkit Blocks: Multiplexor, Timers, 2 Input Logic blocks, User Values, BCD, 8 Input Logic
blocks
Control Loops: Two plus Advanced Control loop
Control types: On/Off with optional PID
Power Feedforward: Yes
Ethernet: 10/100baseT autosensing/negotiating
Protocols: Modbus TCP/IP Master/Slave, EtherNet/IP Client/Server, FTP
Network Addressing: DHCP or Fixed (static) IP addressing
Processor Datasheet 0812© Continuous development may cause this specification to change without notice.