108 ELECTRICAL AND ELECTRONICS LAB
SYLLABUS
1. Assemble house wiring including earthing for 1- phase energy meter, MCB,ceiling fan, tube
light, three pin socket and a lamp operated from two different positions. Basic functional
study of components used in house wiring.
2. .Prepare the connection of ceiling fan along with the regulator and vary the speed.
3. Prepare the connection of single phase induction motor through 1-Phase Auto- transformer
and vary the speed.
4. Prepare the connection of three phase squirrel cage induction motor through Phase Auto-
transformer and vary the speed.
5. Prepare the connection of Fluorescent Lamp, Sodium Vapour and Halogen Lamp and
measure voltage ,current and power in the ckt
Stani Memorial College of Engineering And Technology, Phagi
Electrical Engineering
108 Electrical And Electronics Engineering Lab Manual
3
EXPERIMENT NO. 1
Aim: - Assemble house wiring including earthing for 1-phase energy meter, MCB, celling fan, tube
light, three pin socket, a lamp operated from two different position and Basic functional study of
component used in house wiring.
Apparatus Required: -
S.No. Name Rating Quantity
1 Lamp holder 6A, 250V. 1
2 Ceiling rose 5A, 250V. 2
3 Switches( one way) 5A, 250V. 4
4 Socket outlet 5A, 250V. 1
5 Lamp 100w/200w 1/1
6 MCB B16, 250V 1/1
7 Tube light 20 W/40 W 250V. 1
8 Connecting leads ------------ As per required
9 Screw drivers ------------ As per required
Theory:-
The connection diagram of one lamp, one tube light (connected through ceiling rose), one fan (which
is connected through ceiling rose) and switches in looping system in fig (1).
1. Element of a circuit: - Wire diagram can be intimidating at first, but with a basic
understanding of the symbols and language used, they become as valuable and as easy to use
as any tool in your toolbox.
2. Conductor: - These are usually cooper or aluminum wire, and in some cases it can even be
the frame on which the component are mounted.
3. Load: -The load is the components that do all the work, such as a washer motor, heating
element or light bulb
4. Series circuit:- The current that flow in a series circuit will pass through every component in
the circuit.if any component with in the circuit is open or blown , current will not able to
flow through that circuit polarities. The same voltage is applicable to all circuit component
connected in parallel.
Stani Memorial College of Engineering And Technology, Phagi
Electrical Engineering
108 Electrical And Electronics Engineering Lab Manual
4
5. Ground connection:- This connection is very important . it’s usually made with a bare wire
attached to the cabinet to the appliance, which is in turn connected to earth with in the service
panel of our home through a grounded plug.
6. Electrical component:- All electrical circuit must have a load. Loads have many forms and
purposes. An electric dryer or stove uses a resister called a heating element to create heat.
Circuit Diagram:-
Figure
Precaution :-
1. Do not touch any live conductor.
2. Study the symbol of element very carefully.
Procedure:-
1. Make the connection as shown in fig (1).
2. Connect phase terminal at one terminal of switches after connecting MCB.
3. The second terminal of switch should be connected with one terminal of lamp holder, ceiling
rose and socket etc.
4. Connect neutral terminal at other terminal of lamp holder, ceiling rose and socket etc.
5. Connect fan, tube light etc. in ceiling terminals.
6. Turn ON MCB and check by which device is operating, mark it and observe table;
Stani Memorial College of Engineering And Technology, Phagi
Electrical Engineering
108 Electrical And Electronics Engineering Lab Manual
5
Observation Table:-
Device Switch
Lamp(L1) S1
Tubelight/Ceiling Rose S2
Fan/Ceiling Rose S3
5Amp, 5-pin Socket S4
Calculations:-
Result:- we have successfully prepare the connection and studyof house wiring of the given object.
References:-
1. O P Arora: Power Electronics Laboratory-Experiments and Organization, Narosa Pub.
2. P B Zbar: Industrial Electronics- A Text-Lab Manual, Tata McGraw Hill
Viva voice Question:-
Que. 1) Why devices are connected in parallel?
Que.2) What is need of earth wiring in house wiring?
Que.3) What is the difference between ground and earth?
Que.4) What do you mean by 1-unit of energy meter?
Que.5) What is the purpose of energy meter?
Stani Memorial College of Engineering And Technology, Phagi
Electrical Engineering
108 Electrical And Electronics Engineering Lab Manual
6
EXPERIMENT NO. 2
Aim:- Prepare the connection of ceiling fan along with the regulator and vary the speed.
Apparatus Required:-
S. NO. Name Range/rating Type Quantity
1. Fan motor(stator/rotor) 60W, 0.6A,
350rpm
230±10% volt
1 phase Induction
motor
1
2. Capacitor 2.5 MFD±5%
440V AC50Hz,
Max temp 85
-- 1
3. Fan assembly(rod,
blades)
--- -- 1
4. Fan regulator (0-350)rpm Resistance/electroni
cs
1/1
5. Test lamp 200W -- 1
6. Different tools --- -- As per
requirement
7. Multi Meter Analog/digital -- 1
8. Volt meter (0-300)V Moving coil 1
Stani Memorial College of Engineering And Technology, Phagi
Electrical Engineering
108 Electrical And Electronics Engineering Lab Manual
7
Theory:-
CEILING FAN-:
A ceiling fan is a propeller blade and having two or more blades, directly driven by an electric motor
and intended for use with free inlet &outlet. According to use of electric motor fans are two types-
DC Fan:-
DC fans use dc series motor and generally used where dc supply is easily available.
AC Fan:-
AC fans are most commonly used domestic devices, which are generally known.
Different Parts of Ceiling Fan-:
Fig (1) shows the construction diagram of ceiling fan. It is contains following parts-
Figure:- Parts of Ceiling fan
9. Ammeter (0-1)A Moving coil 1
10. Connecting leads --- -- As per
requirement
Stani Memorial College of Engineering And Technology, Phagi
Electrical Engineering
108 Electrical And Electronics Engineering Lab Manual
8
Motor: The motor employed for ceiling fan is generally a single phase, permanent capacitor,split
phase and squirrel cage induction motor. The stator consist of two windings
(a) Starting windings
(b) Running windings
Capacitor: A paper capacitor is provided at the top of the body of the fan. The value of capacitor
depends upon the rating of the fan. The capacity of rating is vary from 2.5 MFD to 3.0 MFD.
Blades: The ceiling fan is fitted with 3 or 4 angular blades of steel sheets or aluminum sheets.
Aluminum blades are lighter and add efficiency of fan. The blades are fixed on the body of fan with
the help of two machines screw.
Canopy: It is the shape of cup which covers thehook and capacitor. It is held on the suspension rod
of the fan where it is screwed. Two canopies are used in each fan and are made of plastic.
A) One for covering hook.
B) Another for covering the capacitor.
Ball-Bearings: Ball-bearings are use for ensuring free moments of rotating parts. They are provided
between rotating and stationary parts. The fans may have single or double ball-bearing.the double
ball bearing are therefore a little costlier.the bearing are made of high quality steel and are regularly
greased so as to provide long life.
Speed Regulator: It is used to control the speed of the fan. They can either electrical or electronic
type.
In electrical type regulator type speed regulator, speed is control by inserting and removing the
resistance in series of fan .
In electronic type regulator , a tric is used to control the speed by varying input voltage.it used to
triggering .
PRINCIPAL OF WORKING:
AC fans has single phase induction motor, which comprises to distributed windings stator rotor
when current given to the motor, the magnetic field is set in the stator windings which experiences a
force in the rotor to move it right angle to the field at the blades attached with the rotor displace the
air.
Stani Memorial College of Engineering And Technology, Phagi
Electrical Engineering
108 Electrical And Electronics Engineering Lab Manual
9
Speed control by regulators: As we know that there are two types of regulators. In the electrical
regulator we use many resistances in seriesand connected with fan in series. At the position 1 the
maximum resistances is connected in series, hence current of fan deceases so the speed reduces.
In electronic type regulators, a triac is used to control the speed by varyinginput voltage. Adiac is
used for triggering the triac.
Circuit Diagram:-
Figure
Precaution:-
1. Connection should be proper. Loose connection is not allowed.
2. Do not touch any live wire or part.
3. Before switch on the supply, the connection should be checked by lab assistant.
4. Do not damage the terminals of part or wire etc.
Procedure:-
A) For testing-
1. Connect different circuit.
2.Check condition obtain for each and record.
B) For speed-
1. Connect ceiling fan as shown fig.
2. By varying knob of regulator, check the speed by visualization.
Stani Memorial College of Engineering And Technology, Phagi
Electrical Engineering
108 Electrical And Electronics Engineering Lab Manual
10
Observation Table:-
S.No. Regulator resister Speed(rpm)
1.
2.
3.
Result:- We have successfully prepare the connection of ceiling fan with construction and working
principal. Thus we have got the speed regulation at various regulator resister.
References:-
1. O P Arora: Power Electronics Laboratory-Experiments and Organization, Narosa Pub.
2. P B Zbar: Industrial Electronics- A Text-Lab Manual, Tata McGraw Hill
Viva voice Question:-
Que .1) Name the motor of ceiling fan?
Que.2) What is the function of capacitor in ceiling fan?
Que .3) What is name of insulation of ceiling fan?
Que. 4) Winding are fitted on stator or rotor of ceiling fan ?
Que.5) What happens if capacitor terminal interchanged?
Stani Memorial College of Engineering And Technology, Phagi
Electrical Engineering
108 Electrical And Electronics Engineering Lab Manual
11
EXPERIMENT NO. 3
Aim:- Prepare the connection of Single phase Induction motor through 1-phase Auto-transformer
and vary the speed.
Apparatus Required:-
S.No. Name Type Range /Rating Quantity
1 Single phase induction
Motor
Squirrel-cage 230V, 1 or 2HP, 1500 RPM
50Hz
1
2 Volt meter M I (0-600V)/(0-300V) 1/1
3 Ammeter M I 2A/5A 1/1
4 Auto transformer 1-phase 230V/(0-270V) 1
5 Tachometer Digital 0-2000rpm 1
6 Wattmeter Dynamometer 10/20A, 300/600V,
1800/2000W
2
Theory:-
An induction or asynchronous motor is a type of AC motor where power is supplied to the rotor by
means of electromagnetic induction. These motors are widely used in industrial drives, particularly
poly phase induction motors, because they are rugged and have no brushes. Single-phase versions
are used in small appliances. Their speed is determined by the frequency of the supply current, so
they are most widely used in constant-speed applications, although variable speed versions, using
variable frequency drives are becoming more common. The most common type is the squirrel cage
motor, and this term is sometimes used for induction motors generally.
Basic operation:
In Inductionmotor, the statoris powered with alternating current (poly phase in large machines) and
designed to create a rotating magnetic fieldwhich rotates in time with the AC oscillations. In an
induction motor the rotor rotates at a slower speed than the stator field. Therefore the magnetic field
through the rotor is changing (rotating). The rotor has windings in the form of closed loops of wire.
The rotating magnetic flux induces currents in the windings of the rotor as in a transformer.
According to Lenz's law the rotor windings will try to oppose the cause of production of induced
current in the rotor. The cause of induced current in the rotor is the rotating stator magnetic field, so
Stani Memorial College of Engineering And Technology, Phagi
Electrical Engineering
108 Electrical And Electronics Engineering Lab Manual
12
to oppose this the rotor will startto rotate in the direction of the rotating stator magnetic field to make
the relative speed between rotor and rotating stator magnetic field zero, thus the motor will start.
For these currents to be induced, the speed of the physical rotor must be lower than that of the
stator's rotating magnetic field ( ), or the magnetic field would not be moving relative to the rotor
conductors and no currents would be induced. As the speed of the rotor drops below synchronous
speed, the rotation rate of the magnetic field in the rotor increases, inducing more current in the
windings and creating more torque. The ratio between the rotation rate of the magnetic field as seen
by the rotor (slip speed) and the rotation rate of the stator's rotating field is called "slip". Under load,
the speed drops and the slip increases enough to create sufficient torque to turn the load. For this
reason, induction motors are sometimes referred to as asynchronous motors. An induction motor can
be used as induction generator, or it can be unrolled to form the linear induction motor which can
directly generate linear motion.
Stator:
The stator is made of the several tin lamination of aluminium or cast iron.they are punched and
clamped together to form a hollow cylinder.coils of insulation wires are inserted in to these slots.
Each grouping of coils , together with the core it surround , forms an electromagnet on the
application of ac supply.
Rotor:
These are made of several thin steel lamination with evenly spaced bars, which are made up of
alluminium or copper , along the periphery. In the most popular type of rotor, these bars are
connected at ends mechanically and electrically by the use of rings.The rotor consists of a carrying
the conductor.
Speed of induction motor:
Ns= 120 f / p
Ns=synchronous speed of stator
P= the no. poles
F= supply in freq.
Controlling of 1-phase motor through auto transformer:
Two or more contactors may be used to provide reduced voltage starting of a motor. By using an
auto-transformer or a series inductance, a lower voltage is present at the motor terminals, reducing
starting torque and inrush current. Once the motor has come up to some fraction of its full-load
speed, the starter switches to full voltage at the motor terminals. Since the autotransformer or series
Stani Memorial College of Engineering And Technology, Phagi
Electrical Engineering
108 Electrical And Electronics Engineering Lab Manual
13
reactor only carries the heavy motor starting current for a few seconds, the devices can be much
smaller compared to continuously rated equipment. The transition between reduced and full voltage
may be based on elapsed time, or triggered when a current sensor shows the motor current has began
to reduce.
Circuit Diagram:-
Figure
Figure:-
Precaution:-
1. Connection should be proper. Loose connection is not allowed.
2. Do not touch any live wire or part.
Stani Memorial College of Engineering And Technology, Phagi
Electrical Engineering
108 Electrical And Electronics Engineering Lab Manual
14
3. Before switch on the supply, the connection should be checked by lab assistant.
4. Do not damage the terminals of part or wire etc.
Procedure:-
1. Make connectiondiagram as shown in fig 3.1.
2. Put input voltage at “zero”.
3. Now slowly vary input voltage and measure the speed by Tachometer.
4. Record the value of speed at various voltages.
Observation Table:-
S.No Input voltage
(volt.)
Speed(rpm)
1. 50V
2. 100V
3. 150V
4. 200V
5. 230V
Calculations:-
Results:- Thus we have prepare the connection and working principal of single phase induction
motor through 1-phase auto transformer and got the speed regulation with varying the input voltage.
References:-
1. O P Arora: Power Electronics Laboratory-Experiments and Organization, Narosa Pub.
2. P B Zbar: Industrial Electronics- A Text-Lab Manual, Tata McGraw Hill
Stani Memorial College of Engineering And Technology, Phagi
Electrical Engineering
108 Electrical And Electronics Engineering Lab Manual
15
Viva- Voice:-
Que.1) What is the type of induction motor?
Que.2) What is the speed of induction motor?
Que.3) What is an auto- transformer?
Que.4) What is the function of speed regulator?
Que.5) Which typr of induction motor is self start?
Stani Memorial College of Engineering And Technology, Phagi
Electrical Engineering
108 Electrical And Electronics Engineering Lab Manual
16
EXPERIMENT NO. 4
Aim:- Prepare the connection of 3-phase squirrel cage induction motor through 3-phase auto
transformer and vary the speed.
Apparatus Required:-
S. No. Name Type Range /Rating Quantity
1 3- phase induction
Motor
Squirrel-cage 230V, 1 or 2HP, 1500 RPM
50Hz
1
2 Volt meter M I (0-600V)/(0-300V) 1/1
3 Ammeter M I 2A/5A 1/1
4 Auto transformer 1-phase 230V/(0-270V) 1
5 Tachometer Digital 0-2000rpm 1
6 Wattmeter Dynamometer 10/20A, 300/600V,
1800/2000W
2
Theory:-
3-Induction Motors:
An induction or asynchronous motor is a type of AC motorare widely used in industrial and
commercial application. They are classified either as squirrel cage. These motor are self starting and
use no capacitor, start winding, centrifugal switch or other starting device.
They produce medium to high degrees of starting torque. The power capabilities and efficiency in
these motors range from medium to high compared to their 1- phase counter parts. Popular
application include grinders, lathes etc.
Squirrel cage:-
Almost 90%of 3-phase ac induction motors are use of this type. The rotor is of the squirrel cage type
and its work as explained earlier. The power rating range from one-third to several
hundredhorsepower. Motor of this type, rated one horsepower or larger, cost and can start heavier
loads than their 1-phase.
Stani Memorial College of Engineering And Technology, Phagi
Electrical Engineering
108 Electrical And Electronics Engineering Lab Manual
17
Stator:
The stator is made of the several tin lamination of aluminium or cast iron.they are punched and
clamped together to form a hollow cylinder.coils of insulation wires are inserted in to these slots.
Each grouping of coils , together with the core it surround , forms an electromagnet on the
application of ac supply.
Rotor:
These are made of several thin steel lamination with evenly spaced bars, which are made up of
aluminium or copper , along the periphery. In the most popular type of rotor, these bars are
connected at ends mechanically and electrically by the use of rings.The rotor consists of a carrying
the conductor.
Speed of induction motor:
Ns= 120 f / p
Ns=synchronous speed of stator
P= the no. poles
F= supply in freq.
Basic operation:
In Induction motor, the stator is powered with alternating current (poly phase in large machines) and
designed to create a rotating magnetic field which rotates in time with the AC oscillations. In an
induction motor the rotor rotates at a slower speed than the stator field. Therefore the magnetic field
through the rotor is changing (rotating). The rotor has windings in the form of closed loops of wire.
The rotating magnetic flux induces currents in the windings of the rotor as in a transformer.
According to Lenz's law the rotor windings will try to oppose the cause of production of induced
current in the rotor. The cause of induced current in the rotor is the rotating stator magnetic field, so
to oppose this the rotor will start to rotate in the direction of the rotating stator magnetic field to
make the relative speed between rotor and rotating stator magnetic field zero, thus the motor will
start.
For these currents to be induced, the speed of the physical rotor must be lower than that of the
stator's rotating magnetic field ( ), or the magnetic field would not be moving relative to the rotor
conductors and no currents would be induced. As the speed of the rotor drops below synchronous
Stani Memorial College of Engineering And Technology, Phagi
Electrical Engineering
108 Electrical And Electronics Engineering Lab Manual
18
speed, the rotation rate of the magnetic field in the rotor increases, inducing more current in the
windings and creating more torque. The ratio between the rotation rate of the magnetic field as seen
by the rotor (slip speed) and the rotation rate of the stator's rotating field is called "slip". Under load,
the speed drops and the slip increases enough to create sufficient torque to turn the load. For this
reason, induction motors are sometimes referred to as asynchronous motors. An induction motor can
be used as induction generator, or it can be unrolled to form the linear induction motor which can
directly generate linear motion.
Controlling of 3-phase motor through auto transformer:
Two or more contactors may be used to provide reduced voltage starting of a motor. By using an
auto-transformer or a series inductance, a lower voltage is present at the motor terminals, reducing
starting torque and inrush current. Once the motor has come up to some fraction of its full-load
speed, the starter switches to full voltage at the motor terminals. Since the autotransformer or series
reactor only carries the heavy motor starting current for a few seconds, the devices can be much
smaller compared to continuously rated equipment. The transition between reduced and full voltage
may be based on elapsed time, or triggered when a current sensor shows the motor current has began
to reduce.
Circuit Diagram:-
Figure
Precaution:-
1. Connection should be proper. Loose connection is not allowed.
Stani Memorial College of Engineering And Technology, Phagi
Electrical Engineering
108 Electrical And Electronics Engineering Lab Manual
19
2. Do not touch any live wire or part.
3. Before switch on the supply, the connection should be checked by lab assistant.
4. Do not damage the terminals of part or wire etc.
Procedure:-
1. Makeconnection diagram as shown in fig.
2. Put input voltage at “zero”.
3. Now slowly vary input voltage and measure the speed by Tachometer.
4. Record the value of speed at various voltages.
Observation Table:-
S.No. Input
voltage
(volt.)
Speed(rpm) Current( I) Wattmeter
W1 (P1)
Wattmeter
W2 ( P2)
1.
2.
3.
4.
5.
Calculations:-
Results:- Thus we have successfully prepare the connection and study of operation of 3- phase
squirrel cage induction motor and controlled the speed of induction motor by varying input voltage.
Stani Memorial College of Engineering And Technology, Phagi
Electrical Engineering
108 Electrical And Electronics Engineering Lab Manual
20
References:-
1. O P Arora: Power Electronics Laboratory-Experiments and Organization, Narosa Pub.
2. P B Zbar: Industrial Electronics- A Text-Lab Manual, Tata McGraw Hill
Viva- Voice:-
Que.1) What do you mean by 1 HP?
Que .2) How does rotation of 3-phase induction motor reversed?
Que.3) Why the stator of an induction motor is laminated?
Que 4) Why squirrel cage induction better than slip ring induction motor?
Que-5) What is the phase displacement in space between two windings of single phase induction
motor?
Stani Memorial College of Engineering And Technology, Phagi
Electrical Engineering
108 Electrical And Electronics Engineering Lab Manual
21
EXPERIMENT NO. 5(A)
Aim:- Prepare the connection and testing of a fluorescent tube light.
Apparatus Required:-
S.
No.
Name Range Quantity
1 Fluorescent tube 40W, 230V,
50Hz, 120cm
1
2 Choke coil 40W,230V,
Cos φ=0.5
1
3 Starter Glow type for
20/40/65/80W tube
2
4 Test lamp 15W/100W/200W 1/1/1
5 Connecting leads -------- As per required
Theory:-
A fluorescent lamp is a gas-discharge lamp that uses electricity to excitemercuryvapor. The excited
mercury atoms produce short-wave ultraviolet light that then causes a phosphor to fluoresce,
producing visible light. A fluorescent lamp converts electrical power into useful light more
efficiently than an incandescent lamp. Lower energy cost typically offsets the higher initial cost of
the lamp. The lamp fixture is more costly because it requires a ballast to regulate the current through
the lamp.
A fluorescent lamp contains following parts:-
Construction-:
(1) Fluorescent tube
(2) Choke or ballast
(3) Starter s
(1) Fluorescent tube-:
A fluorescent lamp tube is filled with a gas containing low pressure mercury vapor and argon,
xenon, neon, or krypton. The pressure inside the lamp is around 0.3% of atmospheric pressure. The
Stani Memorial College of Engineering And Technology, Phagi
Electrical Engineering
108 Electrical And Electronics Engineering Lab Manual
22
inner surface of the bulb is coated with a fluorescent (and often slightly phosphorescent) coating
made of varying blends of metallic and rare-earthphosphor salts. The bulb's electrodes are typically
made of coiled tungsten and usually referred to as cathodes because of their prime function of
emitting electrons. For this, they are coated with a mixture of barium, strontium and calcium oxides
chosen to have a low thermionic emissiontemperature. Compact fluorescent lamps have several
small-diameter tubes joined in a bundle of two, four, or six, or a small diameter tube coiled into a
spiral, to provide a high amount of light output in little volume.
(2)
Choke or ballast-:
Instant start ballast starts lamps without heating the cathodes at all by using high voltage (around 600
V). It is the most energy efficient type, but gives the least number of starts from a lamp as emissive
oxides are blasted from the cold cathode surfaces each time the lamp is started. This is the best type
for installations where lamps are not turned on and off very often. Rapid start ballast applies voltage
and heats the cathodes simultaneously. It provides superior lamp life and more cycle life, but uses
slightly more energy as the cathodes in each end of the lamp continue to consume heating power as
the lamp operates. A dimming circuit can be used with dimming ballast, which maintains the heating
current while allowing lamp current to be controlled. Programmed-start ballast is a more advanced
version of rapid start. This ballast applies power to the filaments first, then after a short delay to
allow the cathodes to preheat, applies voltage to the lamps to strike an arc. This ballast gives the best
life and most starts from lamps, and so is preferred for applications with very frequent power cycling
such as vision examination rooms and restrooms with a motion detector switch.
Stani Memorial College of Engineering And Technology, Phagi
Electrical Engineering
108 Electrical And Electronics Engineering Lab Manual
23
Fig. ballast
Starter-:
The automatic glow starter shown in the photograph to the left consists of a small gas-discharge
lamp, containing neon or argon in parallel with a normally-open bi-metallicswitch. It functions as a
time-delay switch, turning the filaments of the fluorescent tube on for a few seconds to start it, and
then turning them off. When power is first applied to the circuit, a glow discharge will appear over
the electrodes in the starter lamp. This glow discharge will heat the gas in the starter and cause the
bi-metallic contact to bend towards the other contact. When the contacts touch, the two filaments of
the fluorescent lamp and the ballast will effectively be switched in series to the supply voltage. The
current through the filaments causes them to heat up and emit electrons into the tube gas by
thermionic emission
Starter
Connection and working of fluorescent lamp-:
Connection of fluorescent lamp is shown in the fig (a). In this connection one pin of both side is
connected with starter’s terminals separately
Stani Memorial College of Engineering And Technology, Phagi
Electrical Engineering
108 Electrical And Electronics Engineering Lab Manual
24
Fig (a) connection of fluorescent lamp
When the light is turned on, the electric power heats up the cathode enough for it to
emit electrons (thermionic emission). These electrons collide with and ionize noble gas atoms inside
the bulb surrounding the filament to form a plasma by the process of impact ionization. As a result
of avalanche ionization, the conductivity of the ionized gas rapidly rises, allowing higher currents to
flow through the lamp.
The fill gas helps determine the operating electrical characteristics of the lamp, but does not give off
light itself. The fill gas effectively increases the distance that electrons travel through the tube, which
allows an electron a greater chance of interacting with a mercury atom. Argon atoms, excited to a
metastable state by impact of an electron, can impart this energy to a neutral mercury atom and
ionize it, described as the Penning effect. This has the benefit of lowering the breakdown and
operating voltage of the lamp, compared to other possible fill gases such as krypton.
Circuit Diagram:-
Figure
Stani Memorial College of Engineering And Technology, Phagi
Electrical Engineering
108 Electrical And Electronics Engineering Lab Manual
25
ADVANTAGE:-
1. Longer life of about 7500 working hours.
2. High efficiency about 40 lumes/watt.
3. It is economical in use in long run.
4. Available in different colors.
DISADVANTAGE:-
1. Its initial cost is too high.
2. Fixing of its accessories takes time.
3. Its power factor is low.
Precaution:-
1. Connection should be proper. Loose connection is not allowed.
2. Do not touch any live wire or part.
3. Before switch on the supply, the connection should be checked by lab assistant.
4. Do not damage the terminals of part or wire etc.
Procedure:-
1. Make the connection as per as diagram.
2. Connections check and give the supply.
3. When lamp does not glow then filament open.
4. When lamp bright glow then filament is short.
5. When dim glow then filament is in proper working condition.
Observation Table:-
S.No. Test For Test Result
1. Choke coil
2. starter
3. Tube light
4. Fluorescent tube
Stani Memorial College of Engineering And Technology, Phagi
Electrical Engineering
108 Electrical And Electronics Engineering Lab Manual
26
Calculations:-
Results:- we have successfully connection and study of fluorescent lamp and testing of testing of its
various parts has been done.
References:-
1. O P Arora: Power Electronics Laboratory-Experiments and Organization, Narosa Pub.
2. P B Zbar: Industrial Electronics- A Text-Lab Manual, Tata McGraw Hill
Viva- Voice:-
Que .1) Filament of lamp is made by….?
Que 2) What is the use of inert gas in lamps?
Que3) Why filament is in coil shape?
Que -4) What is the composition of inert gases used in filament lamp?
Que.-5)What is life of approx. incandesend lamp?
Stani Memorial College of Engineering And Technology, Phagi
Electrical Engineering
108 Electrical And Electronics Engineering Lab Manual
27
EXPERIMENT NO. 5(B)
Aim:- To prepare the connection of halogen lamp and measure voltage and current.
Apparatus Required:-
S.No. Name Range Qty
1. Copper ballast 220-240V,1A,
P.F.=0.5
1
2. Capacitor 250V, 10 MICRO
FARAD
1
3. DPMCB 6A, 250V 1
4. Helogen lamp 500W, 250V 1
5. Helogen lamp holder 5A 1
Theory:-
The halogen lamp is the latest member in the family of incandescent lamp. It numerous advantages
over the ordinary incandescent lamp. As already stated the life and efficiency of an incandescent
lamp fall of with use-partly due to slow evaporation of the filament and partly due to back deposit
formed on the inside of the inside of the bulb.
The addition of small amount of halogen vapours to the filling gas restores port of the evaporated
tungsten vapour back to filament by means of chemical reaction i.e. there is a sort of regeneration
cycle.
Advantage:-
1. No dimensions of lamp miniature size.
2. Long life-20000 hours.
3. Better colour rendition.
Application:-
Halogen lamp (up to 5 KW) –
Playing Field, Large Garden,Car Parking, T.V. , Studio Etc.
Stani Memorial College of Engineering And Technology, Phagi
Electrical Engineering
108 Electrical And Electronics Engineering Lab Manual
28
Circuit Diagram:-
Figure:-
Precaution:-
1. Connection should be proper. Loose connection is not allowed.
2. Do not touch any live wire or part.
3. Before switch on the supply, the connection should be checked by lab assistant.
4. Do not damage the terminals of part or wire etc.
Procedure:-
1. Make the connection as per as diagram.
2. Connections check and give the supply.
3. When lamp does not glow then filament open.
4. When lamp bright glow then filament is short.
5. When dim glow then filament is in proper working condition.
Observation Table:-
S.No Switch Condition Voltage(v) Current(I)
1. S1 On
2. S1 Off
Stani Memorial College of Engineering And Technology, Phagi
Electrical Engineering
108 Electrical And Electronics Engineering Lab Manual
29
Calculations:-
Results:- we have successfullyprepare the connection and study of halogen lamp and measure
voltage and current.
References:-
1. O P Arora: Power Electronics Laboratory-Experiments and Organization, Narosa Pub.
2. P B Zbar: Industrial Electronics- A Text-Lab Manual, Tata McGraw Hill
Viva- Voice:-
Ques 1.)Why halogen lamp popular than other lamps?
Ques 2.) What is diff. b/w resistivity and specific resistance?
Ques 3.)What do you mean by resistor?
Que -4) What is the composition of inert gases used in filament lamp?
Que.-5) What is life of approx. incandesend lamp?
Stani Memorial College of Engineering And Technology, Phagi
Electrical Engineering
108 Electrical And Electronics Engineering Lab Manual
30
EXPERIMENT NO. 5(C)
Aim:- To prepare the connection of sodium vapour lamp and measure voltage and current.
Apparatus Required:-
S.No Name Range QTY.
1. Hpsv lamp 220-250V,70W 1
2. Hpsv lamp holder 5A 1
3. Copper ballast 220-240V,1A, P.F.=0.34 1
4. Igniter 20000V 1
5. Capacitor 250V,10 MICRO FARAD 1
6. DPMCB 6A, 250V 1
7. Leads RED,BLACK,YELLOW 1
Theory:-
The practically lamp of this development of this type of lamp, however was delayed since
ordinary glass cannot with stand the chemical action of hot sodium.
The sodium vapour lamp consists of bulbs containing a small amount of metallic sodium,to
develop enough heat to vaporize the sodium.Since long discharge paths are necessary therefore,
the discharge envelope is usually bent into u-shape.
The lamp operates at temp. 300 degree temp in order to conserve the heat generate and assure the
lamp operating at normal air temp.
The discharge envelope is closed in a special vacuum envelop designed for this purpose. The
lamp must be operated horizontally or nearly so, to keep the sodium well spread out along the
tube, although some small lamp, may be operated vertically lamp up.
The sodium vapour lamp is only suitable for alternate current and therefore requires chocke
control. This requirement is met by operating the lamp for a stray field step-up-tapped auto
transformed auto transformed with an open circuit secondary voltage of 470-480 volts. The
uncorrected power factor is very low.
Stani Memorial College of Engineering And Technology, Phagi
Electrical Engineering
108 Electrical And Electronics Engineering Lab Manual
31
When is not in operation , the sodium is usually in the form of solid deposited on the side walls of
tube, therefore at first when it is connected across the supply mains, the discharge takes places in
the neon gas. The metallic sodium vaporizes and then ionizes.
The efficiency of a sodium vapour lamp under practically condition is about 40-50 lumens/watt. The
major application of this type of lamp is for high way and generator outdoor lighting where colour
discrimination is not required, as required, such as street lighting parks , rail yards,lamps are
manufactured in 45,60,85and is not affected by voltage variation at the end of this period the light
output will be reduced by 15% due to ageing.
Advantage:-
1. No dimensions of lamp miniature size.
2. Long life-20000 hours.
3. Better colour rendition.
Circuit Diagram:-
Figure.
Stani Memorial College of Engineering And Technology, Phagi
Electrical Engineering
108 Electrical And Electronics Engineering Lab Manual
32
Precaution:-
1. Connection should be proper. Loose connection is not allowed.
2. Do not touch any live wire or part.
3. Before switch on the supply, the connection should be checked by lab assistant.
4. Do not damage the terminals of part or wire etc.
Procedure:-
1. Make the connection as per as diagram.
2. Connections check and give the supply.
3. When lamp does not glow then filament open.
4. When lamp bright glow then filament is short.
5. When dim glow then filament is in proper working condition.
Observation Table:-
S.No Switch Condition Voltage(v) Current(I)
1. S1 on
2. S1 off
Calculations:-
Results:- we have successfully connection and study of Sodium vapour lamp with measure the
voltage and current.
References:-
1. O P Arora: Power Electronics Laboratory-Experiments and Organization, Narosa Pub.
2. P B Zbar: Industrial Electronics- A Text-Lab Manual, Tata McGraw Hill
Stani Memorial College of Engineering And Technology, Phagi
Electrical Engineering
108 Electrical And Electronics Engineering Lab Manual
33
Viva- Voice:-
Que.1.) What is the function of ignitor in sodium vapour lamps?
Que.2) What is life and efficiency of SV lamps?
Que3.)How much time taken by sodium vapour lamp to full glow?
Que -4) What is the composition of inert gases used in filament lamp?
Que.-5) What is life of approx. incandesend lamp?
Stani Memorial College of Engineering And Technology, Phagi
Electrical Engineering
108 Electrical And Electronics Engineering Lab Manual
34
Dear Sir,
I am writing this letter to submit my request to release me from lecturer till 30-June-2014 with Stani
Memorial College of Engineering and Technology, Jaipur. Though was enjoying working with this
professional environment of SMCET but some compulsive circumstances made me take this action.
Thank you for all of the support you and the college community have given me. I will never forget
your generosity and the important skill. I will forever cherish the time I spent with my students,
colleagues, and this community.
I will be sure to complete all grading and associated responsibilities before departing this position.
Please let me know what further steps or duties must be completed before my departure. I hope to
stay in touch with you and our community. Thank you again for all of your support.

Más contenido relacionado

La actualidad más candente

Unit 04 Protection of generators and transformers
Unit  04 Protection of generators and transformers Unit  04 Protection of generators and transformers
Unit 04 Protection of generators and transformers PremanandDesai
 
PPT ON 33/11KV SUBSTATION
PPT ON 33/11KV SUBSTATIONPPT ON 33/11KV SUBSTATION
PPT ON 33/11KV SUBSTATIONRavi Phadtare
 
Motor Control Centre
Motor Control CentreMotor Control Centre
Motor Control Centresalehkhan
 
Basics of overcurrent protection
Basics of overcurrent protectionBasics of overcurrent protection
Basics of overcurrent protectionSalim Palayi
 
automatic phase changer in three phase supply
automatic phase changer in three phase supplyautomatic phase changer in three phase supply
automatic phase changer in three phase supplyamaljo joju e
 
Unit 03 Protective relays
Unit  03 Protective relaysUnit  03 Protective relays
Unit 03 Protective relaysPremanandDesai
 
Protective relay
Protective relay Protective relay
Protective relay Uday Wankar
 
transformer slide prsentation
transformer slide prsentation transformer slide prsentation
transformer slide prsentation abu jubayer
 
Over current Relays
Over current RelaysOver current Relays
Over current RelaysASWANTH6270
 
Electrical Engineering Interview Questions
Electrical Engineering Interview QuestionsElectrical Engineering Interview Questions
Electrical Engineering Interview Questionsashiesh0007
 
final year project report
final year project reportfinal year project report
final year project reportAnuj Kumar
 
Relay coordination
Relay coordinationRelay coordination
Relay coordinationD Målîk
 
To control two lamp (in parallel) with one switch
To control two lamp (in parallel) with one switch To control two lamp (in parallel) with one switch
To control two lamp (in parallel) with one switch Salman Jailani
 
switchgear and protection by vala kamlesh
switchgear and protection by vala kamleshswitchgear and protection by vala kamlesh
switchgear and protection by vala kamleshKamlesh Vala
 
Switchgear presentation
Switchgear presentationSwitchgear presentation
Switchgear presentationNadir Baloch
 
Switchgear and protection engineering Lecture 02.pptx
Switchgear and protection engineering Lecture 02.pptxSwitchgear and protection engineering Lecture 02.pptx
Switchgear and protection engineering Lecture 02.pptxLoitaFredy
 

La actualidad más candente (20)

Unit 04 Protection of generators and transformers
Unit  04 Protection of generators and transformers Unit  04 Protection of generators and transformers
Unit 04 Protection of generators and transformers
 
Faults on Power System
Faults on Power SystemFaults on Power System
Faults on Power System
 
PPT ON 33/11KV SUBSTATION
PPT ON 33/11KV SUBSTATIONPPT ON 33/11KV SUBSTATION
PPT ON 33/11KV SUBSTATION
 
Motor Control Centre
Motor Control CentreMotor Control Centre
Motor Control Centre
 
Basics of overcurrent protection
Basics of overcurrent protectionBasics of overcurrent protection
Basics of overcurrent protection
 
automatic phase changer in three phase supply
automatic phase changer in three phase supplyautomatic phase changer in three phase supply
automatic phase changer in three phase supply
 
Unit 03 Protective relays
Unit  03 Protective relaysUnit  03 Protective relays
Unit 03 Protective relays
 
Protective relay
Protective relay Protective relay
Protective relay
 
transformer slide prsentation
transformer slide prsentation transformer slide prsentation
transformer slide prsentation
 
Contactors relays
Contactors  relaysContactors  relays
Contactors relays
 
Over current Relays
Over current RelaysOver current Relays
Over current Relays
 
Testing of transformer
Testing of transformerTesting of transformer
Testing of transformer
 
Electrical Engineering Interview Questions
Electrical Engineering Interview QuestionsElectrical Engineering Interview Questions
Electrical Engineering Interview Questions
 
final year project report
final year project reportfinal year project report
final year project report
 
Relay coordination
Relay coordinationRelay coordination
Relay coordination
 
To control two lamp (in parallel) with one switch
To control two lamp (in parallel) with one switch To control two lamp (in parallel) with one switch
To control two lamp (in parallel) with one switch
 
switchgear and protection by vala kamlesh
switchgear and protection by vala kamleshswitchgear and protection by vala kamlesh
switchgear and protection by vala kamlesh
 
Switchgear presentation
Switchgear presentationSwitchgear presentation
Switchgear presentation
 
Switchgear and protection engineering Lecture 02.pptx
Switchgear and protection engineering Lecture 02.pptxSwitchgear and protection engineering Lecture 02.pptx
Switchgear and protection engineering Lecture 02.pptx
 
Transformer Failures and Case Studies
Transformer Failures and Case StudiesTransformer Failures and Case Studies
Transformer Failures and Case Studies
 

Destacado

Basic electrical lab manual
Basic electrical lab manualBasic electrical lab manual
Basic electrical lab manualDevashish Meena
 
Engineering practice lab manual for electronics
Engineering practice lab manual for electronicsEngineering practice lab manual for electronics
Engineering practice lab manual for electronicsPadhu Ar
 
EC 2 lab manual with circulits
EC 2 lab manual with circulitsEC 2 lab manual with circulits
EC 2 lab manual with circulitsMurugan Dhandapani
 
Electrical machines 2 lab manual
Electrical machines 2 lab manualElectrical machines 2 lab manual
Electrical machines 2 lab manualNaga Sai Chaitanya
 
Electrical machine lab
Electrical machine labElectrical machine lab
Electrical machine labDHEERAJ DHAKAR
 
Analog electronics LAB MANUAL
Analog electronics LAB MANUALAnalog electronics LAB MANUAL
Analog electronics LAB MANUALAJAL A J
 
Electronics Lab Manual by Er. Swapnil V. Kaware
Electronics Lab Manual by Er. Swapnil V. KawareElectronics Lab Manual by Er. Swapnil V. Kaware
Electronics Lab Manual by Er. Swapnil V. KawareProf. Swapnil V. Kaware
 
Em ii lab manual 28.10.08 latest
Em ii lab manual 28.10.08 latestEm ii lab manual 28.10.08 latest
Em ii lab manual 28.10.08 latestraj_e2004
 
Electronic Devices and Circuits Manual
Electronic Devices and Circuits ManualElectronic Devices and Circuits Manual
Electronic Devices and Circuits ManualShashank Thawkar
 
BSc I year practicals
BSc I year practicalsBSc I year practicals
BSc I year practicalsSARITHA REDDY
 
2 electrical machines lab
2 electrical machines lab2 electrical machines lab
2 electrical machines labzeta eksa
 
Circuit Analysis Lab
Circuit Analysis LabCircuit Analysis Lab
Circuit Analysis LabSachin Airan
 
Electronic circuit design lab manual
Electronic circuit design lab manualElectronic circuit design lab manual
Electronic circuit design lab manualawais ahmad
 

Destacado (20)

Basic electrical lab manual
Basic electrical lab manualBasic electrical lab manual
Basic electrical lab manual
 
Engineering practice lab manual for electronics
Engineering practice lab manual for electronicsEngineering practice lab manual for electronics
Engineering practice lab manual for electronics
 
EC 2 lab manual with circulits
EC 2 lab manual with circulitsEC 2 lab manual with circulits
EC 2 lab manual with circulits
 
Power Electronics lab manual BE EEE
Power Electronics lab manual BE EEEPower Electronics lab manual BE EEE
Power Electronics lab manual BE EEE
 
Electrical machines 2 lab manual
Electrical machines 2 lab manualElectrical machines 2 lab manual
Electrical machines 2 lab manual
 
E&e lab manual
E&e lab manualE&e lab manual
E&e lab manual
 
Electrical machine lab
Electrical machine labElectrical machine lab
Electrical machine lab
 
pe lab manual
pe lab manualpe lab manual
pe lab manual
 
Analog electronics LAB MANUAL
Analog electronics LAB MANUALAnalog electronics LAB MANUAL
Analog electronics LAB MANUAL
 
Ec ii lab manual
Ec ii lab manualEc ii lab manual
Ec ii lab manual
 
Electronics Lab Manual by Er. Swapnil V. Kaware
Electronics Lab Manual by Er. Swapnil V. KawareElectronics Lab Manual by Er. Swapnil V. Kaware
Electronics Lab Manual by Er. Swapnil V. Kaware
 
Em ii lab manual 28.10.08 latest
Em ii lab manual 28.10.08 latestEm ii lab manual 28.10.08 latest
Em ii lab manual 28.10.08 latest
 
Electronic Devices and Circuits Manual
Electronic Devices and Circuits ManualElectronic Devices and Circuits Manual
Electronic Devices and Circuits Manual
 
Lic lab manual 1
Lic lab manual 1Lic lab manual 1
Lic lab manual 1
 
Machine lab manual
Machine lab manualMachine lab manual
Machine lab manual
 
BSc I year practicals
BSc I year practicalsBSc I year practicals
BSc I year practicals
 
2 electrical machines lab
2 electrical machines lab2 electrical machines lab
2 electrical machines lab
 
Power Electronics Lab Manual ME PED
Power Electronics Lab Manual ME PEDPower Electronics Lab Manual ME PED
Power Electronics Lab Manual ME PED
 
Circuit Analysis Lab
Circuit Analysis LabCircuit Analysis Lab
Circuit Analysis Lab
 
Electronic circuit design lab manual
Electronic circuit design lab manualElectronic circuit design lab manual
Electronic circuit design lab manual
 

Similar a Electrical and electronics Lab Manual

Maintain and repair consumer electronics
Maintain and repair consumer electronicsMaintain and repair consumer electronics
Maintain and repair consumer electronicsMannaseh Lina
 
LOW VOLTAGE CONTROL PANEL, SWITHGEAR, OVERLOAD PROTECTION, STARTING METHODS
LOW VOLTAGE CONTROL PANEL, SWITHGEAR, OVERLOAD PROTECTION, STARTING METHODSLOW VOLTAGE CONTROL PANEL, SWITHGEAR, OVERLOAD PROTECTION, STARTING METHODS
LOW VOLTAGE CONTROL PANEL, SWITHGEAR, OVERLOAD PROTECTION, STARTING METHODSJayant Suthar
 
Report on minor project
Report on minor projectReport on minor project
Report on minor projectAnil Maurya
 
IRJET- Intelligent Power Emulator
IRJET-  	  Intelligent Power EmulatorIRJET-  	  Intelligent Power Emulator
IRJET- Intelligent Power EmulatorIRJET Journal
 
IRJET- Intelligent Power Emulator
IRJET- Intelligent Power EmulatorIRJET- Intelligent Power Emulator
IRJET- Intelligent Power EmulatorIRJET Journal
 
electrical and electronics lab viva questions
electrical and electronics lab viva questionselectrical and electronics lab viva questions
electrical and electronics lab viva questionsCyber4Tech
 
Lab Manual IE 3162415.pdf
Lab Manual IE 3162415.pdfLab Manual IE 3162415.pdf
Lab Manual IE 3162415.pdfTechShah
 
THE FABRICATION OF REGULATED DC POWER SUPPLY
THE FABRICATION OF REGULATED DC POWER SUPPLYTHE FABRICATION OF REGULATED DC POWER SUPPLY
THE FABRICATION OF REGULATED DC POWER SUPPLYSAURAV DAYAL SING
 
Railway workshop jodhpur
Railway workshop jodhpurRailway workshop jodhpur
Railway workshop jodhpurMAHESH SONI
 
ICHVEPS23-OS1-B6_449-Jujun & S.Abduh.pdf
ICHVEPS23-OS1-B6_449-Jujun & S.Abduh.pdfICHVEPS23-OS1-B6_449-Jujun & S.Abduh.pdf
ICHVEPS23-OS1-B6_449-Jujun & S.Abduh.pdfSyamsirAbduh2
 
Speed Control of Induction Motor Using Hysteresis Method
Speed Control of Induction Motor Using Hysteresis MethodSpeed Control of Induction Motor Using Hysteresis Method
Speed Control of Induction Motor Using Hysteresis MethodIRJET Journal
 
Study and design of a grid tie Photo-voltaic system
Study and design of a grid tie Photo-voltaic systemStudy and design of a grid tie Photo-voltaic system
Study and design of a grid tie Photo-voltaic systemHamatto Shafi
 
Vocational Training Report ( Sealdah Power House)
Vocational Training Report ( Sealdah Power House)Vocational Training Report ( Sealdah Power House)
Vocational Training Report ( Sealdah Power House)shovandey07
 
IRJET- Furnace Temperature Indicator CUM Controller
IRJET- Furnace Temperature Indicator CUM ControllerIRJET- Furnace Temperature Indicator CUM Controller
IRJET- Furnace Temperature Indicator CUM ControllerIRJET Journal
 
electropneumatics-circuits suit for electrical.pptx
electropneumatics-circuits suit for electrical.pptxelectropneumatics-circuits suit for electrical.pptx
electropneumatics-circuits suit for electrical.pptxRusselLabusan1
 

Similar a Electrical and electronics Lab Manual (20)

Maintain and repair consumer electronics
Maintain and repair consumer electronicsMaintain and repair consumer electronics
Maintain and repair consumer electronics
 
avi
aviavi
avi
 
LOW VOLTAGE CONTROL PANEL, SWITHGEAR, OVERLOAD PROTECTION, STARTING METHODS
LOW VOLTAGE CONTROL PANEL, SWITHGEAR, OVERLOAD PROTECTION, STARTING METHODSLOW VOLTAGE CONTROL PANEL, SWITHGEAR, OVERLOAD PROTECTION, STARTING METHODS
LOW VOLTAGE CONTROL PANEL, SWITHGEAR, OVERLOAD PROTECTION, STARTING METHODS
 
Report on minor project
Report on minor projectReport on minor project
Report on minor project
 
IRJET- Intelligent Power Emulator
IRJET-  	  Intelligent Power EmulatorIRJET-  	  Intelligent Power Emulator
IRJET- Intelligent Power Emulator
 
IRJET- Intelligent Power Emulator
IRJET- Intelligent Power EmulatorIRJET- Intelligent Power Emulator
IRJET- Intelligent Power Emulator
 
Siemens
SiemensSiemens
Siemens
 
electrical and electronics lab viva questions
electrical and electronics lab viva questionselectrical and electronics lab viva questions
electrical and electronics lab viva questions
 
Lab Manual IE 3162415.pdf
Lab Manual IE 3162415.pdfLab Manual IE 3162415.pdf
Lab Manual IE 3162415.pdf
 
Wiring doc
Wiring docWiring doc
Wiring doc
 
THE FABRICATION OF REGULATED DC POWER SUPPLY
THE FABRICATION OF REGULATED DC POWER SUPPLYTHE FABRICATION OF REGULATED DC POWER SUPPLY
THE FABRICATION OF REGULATED DC POWER SUPPLY
 
Experiment 3.pptx
Experiment 3.pptxExperiment 3.pptx
Experiment 3.pptx
 
Railway workshop jodhpur
Railway workshop jodhpurRailway workshop jodhpur
Railway workshop jodhpur
 
ICHVEPS23-OS1-B6_449-Jujun & S.Abduh.pdf
ICHVEPS23-OS1-B6_449-Jujun & S.Abduh.pdfICHVEPS23-OS1-B6_449-Jujun & S.Abduh.pdf
ICHVEPS23-OS1-B6_449-Jujun & S.Abduh.pdf
 
Speed Control of Induction Motor Using Hysteresis Method
Speed Control of Induction Motor Using Hysteresis MethodSpeed Control of Induction Motor Using Hysteresis Method
Speed Control of Induction Motor Using Hysteresis Method
 
Study and design of a grid tie Photo-voltaic system
Study and design of a grid tie Photo-voltaic systemStudy and design of a grid tie Photo-voltaic system
Study and design of a grid tie Photo-voltaic system
 
Vocational Training Report ( Sealdah Power House)
Vocational Training Report ( Sealdah Power House)Vocational Training Report ( Sealdah Power House)
Vocational Training Report ( Sealdah Power House)
 
IRJET- Furnace Temperature Indicator CUM Controller
IRJET- Furnace Temperature Indicator CUM ControllerIRJET- Furnace Temperature Indicator CUM Controller
IRJET- Furnace Temperature Indicator CUM Controller
 
Power supply
Power supplyPower supply
Power supply
 
electropneumatics-circuits suit for electrical.pptx
electropneumatics-circuits suit for electrical.pptxelectropneumatics-circuits suit for electrical.pptx
electropneumatics-circuits suit for electrical.pptx
 

Más de Sachin Airan

Power System Modelling And Simulation Lab
Power System Modelling And Simulation LabPower System Modelling And Simulation Lab
Power System Modelling And Simulation LabSachin Airan
 
Professional Ethics And Disaster Management
Professional Ethics And Disaster ManagementProfessional Ethics And Disaster Management
Professional Ethics And Disaster ManagementSachin Airan
 
Huminity and Social Science Lab Manual
Huminity and Social Science Lab ManualHuminity and Social Science Lab Manual
Huminity and Social Science Lab ManualSachin Airan
 
Industrial Economics and Management Lab Manual
Industrial Economics and Management Lab ManualIndustrial Economics and Management Lab Manual
Industrial Economics and Management Lab ManualSachin Airan
 
Lab manual psd v sem experiment no 7
Lab manual psd v sem experiment no 7Lab manual psd v sem experiment no 7
Lab manual psd v sem experiment no 7Sachin Airan
 
Lab manual psd v sem experiment no 5
Lab manual psd v sem experiment no 5Lab manual psd v sem experiment no 5
Lab manual psd v sem experiment no 5Sachin Airan
 
Lab manual psd v sem experiment no 4
Lab manual psd v sem experiment no 4Lab manual psd v sem experiment no 4
Lab manual psd v sem experiment no 4Sachin Airan
 
Lab manual psd v sem experiment no 3
Lab manual psd v sem experiment no 3Lab manual psd v sem experiment no 3
Lab manual psd v sem experiment no 3Sachin Airan
 
Lab manual psd v sem experiment no 2
Lab manual psd v sem experiment no 2Lab manual psd v sem experiment no 2
Lab manual psd v sem experiment no 2Sachin Airan
 
Lab manual psd v sem experiment no 1
Lab manual psd v sem experiment no 1Lab manual psd v sem experiment no 1
Lab manual psd v sem experiment no 1Sachin Airan
 
Lab manual psd v sem experiment no 6
Lab manual psd v sem experiment no 6Lab manual psd v sem experiment no 6
Lab manual psd v sem experiment no 6Sachin Airan
 

Más de Sachin Airan (11)

Power System Modelling And Simulation Lab
Power System Modelling And Simulation LabPower System Modelling And Simulation Lab
Power System Modelling And Simulation Lab
 
Professional Ethics And Disaster Management
Professional Ethics And Disaster ManagementProfessional Ethics And Disaster Management
Professional Ethics And Disaster Management
 
Huminity and Social Science Lab Manual
Huminity and Social Science Lab ManualHuminity and Social Science Lab Manual
Huminity and Social Science Lab Manual
 
Industrial Economics and Management Lab Manual
Industrial Economics and Management Lab ManualIndustrial Economics and Management Lab Manual
Industrial Economics and Management Lab Manual
 
Lab manual psd v sem experiment no 7
Lab manual psd v sem experiment no 7Lab manual psd v sem experiment no 7
Lab manual psd v sem experiment no 7
 
Lab manual psd v sem experiment no 5
Lab manual psd v sem experiment no 5Lab manual psd v sem experiment no 5
Lab manual psd v sem experiment no 5
 
Lab manual psd v sem experiment no 4
Lab manual psd v sem experiment no 4Lab manual psd v sem experiment no 4
Lab manual psd v sem experiment no 4
 
Lab manual psd v sem experiment no 3
Lab manual psd v sem experiment no 3Lab manual psd v sem experiment no 3
Lab manual psd v sem experiment no 3
 
Lab manual psd v sem experiment no 2
Lab manual psd v sem experiment no 2Lab manual psd v sem experiment no 2
Lab manual psd v sem experiment no 2
 
Lab manual psd v sem experiment no 1
Lab manual psd v sem experiment no 1Lab manual psd v sem experiment no 1
Lab manual psd v sem experiment no 1
 
Lab manual psd v sem experiment no 6
Lab manual psd v sem experiment no 6Lab manual psd v sem experiment no 6
Lab manual psd v sem experiment no 6
 

Último

The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...ranjana rawat
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Dr.Costas Sachpazis
 
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Dr.Costas Sachpazis
 
Russian Call Girls in Nagpur Grishma Call 7001035870 Meet With Nagpur Escorts
Russian Call Girls in Nagpur Grishma Call 7001035870 Meet With Nagpur EscortsRussian Call Girls in Nagpur Grishma Call 7001035870 Meet With Nagpur Escorts
Russian Call Girls in Nagpur Grishma Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxAsutosh Ranjan
 
Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingPorous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingrakeshbaidya232001
 
UNIT-III FMM. DIMENSIONAL ANALYSIS
UNIT-III FMM.        DIMENSIONAL ANALYSISUNIT-III FMM.        DIMENSIONAL ANALYSIS
UNIT-III FMM. DIMENSIONAL ANALYSISrknatarajan
 
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdfONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdfKamal Acharya
 
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Call Girls in Nagpur High Profile
 
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLSMANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLSSIVASHANKAR N
 
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
Glass Ceramics: Processing and Properties
Glass Ceramics: Processing and PropertiesGlass Ceramics: Processing and Properties
Glass Ceramics: Processing and PropertiesPrabhanshu Chaturvedi
 
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service NashikCall Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service NashikCall Girls in Nagpur High Profile
 
result management system report for college project
result management system report for college projectresult management system report for college project
result management system report for college projectTonystark477637
 
Java Programming :Event Handling(Types of Events)
Java Programming :Event Handling(Types of Events)Java Programming :Event Handling(Types of Events)
Java Programming :Event Handling(Types of Events)simmis5
 
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Bookingdharasingh5698
 
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINEMANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINESIVASHANKAR N
 
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...ranjana rawat
 

Último (20)

The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
 
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
 
Water Industry Process Automation & Control Monthly - April 2024
Water Industry Process Automation & Control Monthly - April 2024Water Industry Process Automation & Control Monthly - April 2024
Water Industry Process Automation & Control Monthly - April 2024
 
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
 
Russian Call Girls in Nagpur Grishma Call 7001035870 Meet With Nagpur Escorts
Russian Call Girls in Nagpur Grishma Call 7001035870 Meet With Nagpur EscortsRussian Call Girls in Nagpur Grishma Call 7001035870 Meet With Nagpur Escorts
Russian Call Girls in Nagpur Grishma Call 7001035870 Meet With Nagpur Escorts
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptx
 
Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingPorous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writing
 
UNIT-III FMM. DIMENSIONAL ANALYSIS
UNIT-III FMM.        DIMENSIONAL ANALYSISUNIT-III FMM.        DIMENSIONAL ANALYSIS
UNIT-III FMM. DIMENSIONAL ANALYSIS
 
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdfONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
 
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
 
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLSMANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
 
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
 
Glass Ceramics: Processing and Properties
Glass Ceramics: Processing and PropertiesGlass Ceramics: Processing and Properties
Glass Ceramics: Processing and Properties
 
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service NashikCall Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
 
result management system report for college project
result management system report for college projectresult management system report for college project
result management system report for college project
 
Java Programming :Event Handling(Types of Events)
Java Programming :Event Handling(Types of Events)Java Programming :Event Handling(Types of Events)
Java Programming :Event Handling(Types of Events)
 
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
 
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINEMANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
 
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
 

Electrical and electronics Lab Manual

  • 1. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 1 LAB MANUAL Subject Code: 108 ELECTRICAL AND ELECTRONICS ENGINEERING LAB (I B. Tech I Semester All Branch) Established in year 2000 DEPARTMENT OF ELECTRICAL ENGINEERING STANI MEMORIAL COLLEGE OF ENGINEERING & TECHNOLOGY, PHAGI, JAIPUR – 303005 Website: www.smcet.in
  • 2. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 2 108 ELECTRICAL AND ELECTRONICS LAB SYLLABUS 1. Assemble house wiring including earthing for 1- phase energy meter, MCB,ceiling fan, tube light, three pin socket and a lamp operated from two different positions. Basic functional study of components used in house wiring. 2. .Prepare the connection of ceiling fan along with the regulator and vary the speed. 3. Prepare the connection of single phase induction motor through 1-Phase Auto- transformer and vary the speed. 4. Prepare the connection of three phase squirrel cage induction motor through Phase Auto- transformer and vary the speed. 5. Prepare the connection of Fluorescent Lamp, Sodium Vapour and Halogen Lamp and measure voltage ,current and power in the ckt
  • 3. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 3 EXPERIMENT NO. 1 Aim: - Assemble house wiring including earthing for 1-phase energy meter, MCB, celling fan, tube light, three pin socket, a lamp operated from two different position and Basic functional study of component used in house wiring. Apparatus Required: - S.No. Name Rating Quantity 1 Lamp holder 6A, 250V. 1 2 Ceiling rose 5A, 250V. 2 3 Switches( one way) 5A, 250V. 4 4 Socket outlet 5A, 250V. 1 5 Lamp 100w/200w 1/1 6 MCB B16, 250V 1/1 7 Tube light 20 W/40 W 250V. 1 8 Connecting leads ------------ As per required 9 Screw drivers ------------ As per required Theory:- The connection diagram of one lamp, one tube light (connected through ceiling rose), one fan (which is connected through ceiling rose) and switches in looping system in fig (1). 1. Element of a circuit: - Wire diagram can be intimidating at first, but with a basic understanding of the symbols and language used, they become as valuable and as easy to use as any tool in your toolbox. 2. Conductor: - These are usually cooper or aluminum wire, and in some cases it can even be the frame on which the component are mounted. 3. Load: -The load is the components that do all the work, such as a washer motor, heating element or light bulb 4. Series circuit:- The current that flow in a series circuit will pass through every component in the circuit.if any component with in the circuit is open or blown , current will not able to flow through that circuit polarities. The same voltage is applicable to all circuit component connected in parallel.
  • 4. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 4 5. Ground connection:- This connection is very important . it’s usually made with a bare wire attached to the cabinet to the appliance, which is in turn connected to earth with in the service panel of our home through a grounded plug. 6. Electrical component:- All electrical circuit must have a load. Loads have many forms and purposes. An electric dryer or stove uses a resister called a heating element to create heat. Circuit Diagram:- Figure Precaution :- 1. Do not touch any live conductor. 2. Study the symbol of element very carefully. Procedure:- 1. Make the connection as shown in fig (1). 2. Connect phase terminal at one terminal of switches after connecting MCB. 3. The second terminal of switch should be connected with one terminal of lamp holder, ceiling rose and socket etc. 4. Connect neutral terminal at other terminal of lamp holder, ceiling rose and socket etc. 5. Connect fan, tube light etc. in ceiling terminals. 6. Turn ON MCB and check by which device is operating, mark it and observe table;
  • 5. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 5 Observation Table:- Device Switch Lamp(L1) S1 Tubelight/Ceiling Rose S2 Fan/Ceiling Rose S3 5Amp, 5-pin Socket S4 Calculations:- Result:- we have successfully prepare the connection and studyof house wiring of the given object. References:- 1. O P Arora: Power Electronics Laboratory-Experiments and Organization, Narosa Pub. 2. P B Zbar: Industrial Electronics- A Text-Lab Manual, Tata McGraw Hill Viva voice Question:- Que. 1) Why devices are connected in parallel? Que.2) What is need of earth wiring in house wiring? Que.3) What is the difference between ground and earth? Que.4) What do you mean by 1-unit of energy meter? Que.5) What is the purpose of energy meter?
  • 6. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 6 EXPERIMENT NO. 2 Aim:- Prepare the connection of ceiling fan along with the regulator and vary the speed. Apparatus Required:- S. NO. Name Range/rating Type Quantity 1. Fan motor(stator/rotor) 60W, 0.6A, 350rpm 230±10% volt 1 phase Induction motor 1 2. Capacitor 2.5 MFD±5% 440V AC50Hz, Max temp 85 -- 1 3. Fan assembly(rod, blades) --- -- 1 4. Fan regulator (0-350)rpm Resistance/electroni cs 1/1 5. Test lamp 200W -- 1 6. Different tools --- -- As per requirement 7. Multi Meter Analog/digital -- 1 8. Volt meter (0-300)V Moving coil 1
  • 7. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 7 Theory:- CEILING FAN-: A ceiling fan is a propeller blade and having two or more blades, directly driven by an electric motor and intended for use with free inlet &outlet. According to use of electric motor fans are two types- DC Fan:- DC fans use dc series motor and generally used where dc supply is easily available. AC Fan:- AC fans are most commonly used domestic devices, which are generally known. Different Parts of Ceiling Fan-: Fig (1) shows the construction diagram of ceiling fan. It is contains following parts- Figure:- Parts of Ceiling fan 9. Ammeter (0-1)A Moving coil 1 10. Connecting leads --- -- As per requirement
  • 8. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 8 Motor: The motor employed for ceiling fan is generally a single phase, permanent capacitor,split phase and squirrel cage induction motor. The stator consist of two windings (a) Starting windings (b) Running windings Capacitor: A paper capacitor is provided at the top of the body of the fan. The value of capacitor depends upon the rating of the fan. The capacity of rating is vary from 2.5 MFD to 3.0 MFD. Blades: The ceiling fan is fitted with 3 or 4 angular blades of steel sheets or aluminum sheets. Aluminum blades are lighter and add efficiency of fan. The blades are fixed on the body of fan with the help of two machines screw. Canopy: It is the shape of cup which covers thehook and capacitor. It is held on the suspension rod of the fan where it is screwed. Two canopies are used in each fan and are made of plastic. A) One for covering hook. B) Another for covering the capacitor. Ball-Bearings: Ball-bearings are use for ensuring free moments of rotating parts. They are provided between rotating and stationary parts. The fans may have single or double ball-bearing.the double ball bearing are therefore a little costlier.the bearing are made of high quality steel and are regularly greased so as to provide long life. Speed Regulator: It is used to control the speed of the fan. They can either electrical or electronic type. In electrical type regulator type speed regulator, speed is control by inserting and removing the resistance in series of fan . In electronic type regulator , a tric is used to control the speed by varying input voltage.it used to triggering . PRINCIPAL OF WORKING: AC fans has single phase induction motor, which comprises to distributed windings stator rotor when current given to the motor, the magnetic field is set in the stator windings which experiences a force in the rotor to move it right angle to the field at the blades attached with the rotor displace the air.
  • 9. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 9 Speed control by regulators: As we know that there are two types of regulators. In the electrical regulator we use many resistances in seriesand connected with fan in series. At the position 1 the maximum resistances is connected in series, hence current of fan deceases so the speed reduces. In electronic type regulators, a triac is used to control the speed by varyinginput voltage. Adiac is used for triggering the triac. Circuit Diagram:- Figure Precaution:- 1. Connection should be proper. Loose connection is not allowed. 2. Do not touch any live wire or part. 3. Before switch on the supply, the connection should be checked by lab assistant. 4. Do not damage the terminals of part or wire etc. Procedure:- A) For testing- 1. Connect different circuit. 2.Check condition obtain for each and record. B) For speed- 1. Connect ceiling fan as shown fig. 2. By varying knob of regulator, check the speed by visualization.
  • 10. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 10 Observation Table:- S.No. Regulator resister Speed(rpm) 1. 2. 3. Result:- We have successfully prepare the connection of ceiling fan with construction and working principal. Thus we have got the speed regulation at various regulator resister. References:- 1. O P Arora: Power Electronics Laboratory-Experiments and Organization, Narosa Pub. 2. P B Zbar: Industrial Electronics- A Text-Lab Manual, Tata McGraw Hill Viva voice Question:- Que .1) Name the motor of ceiling fan? Que.2) What is the function of capacitor in ceiling fan? Que .3) What is name of insulation of ceiling fan? Que. 4) Winding are fitted on stator or rotor of ceiling fan ? Que.5) What happens if capacitor terminal interchanged?
  • 11. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 11 EXPERIMENT NO. 3 Aim:- Prepare the connection of Single phase Induction motor through 1-phase Auto-transformer and vary the speed. Apparatus Required:- S.No. Name Type Range /Rating Quantity 1 Single phase induction Motor Squirrel-cage 230V, 1 or 2HP, 1500 RPM 50Hz 1 2 Volt meter M I (0-600V)/(0-300V) 1/1 3 Ammeter M I 2A/5A 1/1 4 Auto transformer 1-phase 230V/(0-270V) 1 5 Tachometer Digital 0-2000rpm 1 6 Wattmeter Dynamometer 10/20A, 300/600V, 1800/2000W 2 Theory:- An induction or asynchronous motor is a type of AC motor where power is supplied to the rotor by means of electromagnetic induction. These motors are widely used in industrial drives, particularly poly phase induction motors, because they are rugged and have no brushes. Single-phase versions are used in small appliances. Their speed is determined by the frequency of the supply current, so they are most widely used in constant-speed applications, although variable speed versions, using variable frequency drives are becoming more common. The most common type is the squirrel cage motor, and this term is sometimes used for induction motors generally. Basic operation: In Inductionmotor, the statoris powered with alternating current (poly phase in large machines) and designed to create a rotating magnetic fieldwhich rotates in time with the AC oscillations. In an induction motor the rotor rotates at a slower speed than the stator field. Therefore the magnetic field through the rotor is changing (rotating). The rotor has windings in the form of closed loops of wire. The rotating magnetic flux induces currents in the windings of the rotor as in a transformer. According to Lenz's law the rotor windings will try to oppose the cause of production of induced current in the rotor. The cause of induced current in the rotor is the rotating stator magnetic field, so
  • 12. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 12 to oppose this the rotor will startto rotate in the direction of the rotating stator magnetic field to make the relative speed between rotor and rotating stator magnetic field zero, thus the motor will start. For these currents to be induced, the speed of the physical rotor must be lower than that of the stator's rotating magnetic field ( ), or the magnetic field would not be moving relative to the rotor conductors and no currents would be induced. As the speed of the rotor drops below synchronous speed, the rotation rate of the magnetic field in the rotor increases, inducing more current in the windings and creating more torque. The ratio between the rotation rate of the magnetic field as seen by the rotor (slip speed) and the rotation rate of the stator's rotating field is called "slip". Under load, the speed drops and the slip increases enough to create sufficient torque to turn the load. For this reason, induction motors are sometimes referred to as asynchronous motors. An induction motor can be used as induction generator, or it can be unrolled to form the linear induction motor which can directly generate linear motion. Stator: The stator is made of the several tin lamination of aluminium or cast iron.they are punched and clamped together to form a hollow cylinder.coils of insulation wires are inserted in to these slots. Each grouping of coils , together with the core it surround , forms an electromagnet on the application of ac supply. Rotor: These are made of several thin steel lamination with evenly spaced bars, which are made up of alluminium or copper , along the periphery. In the most popular type of rotor, these bars are connected at ends mechanically and electrically by the use of rings.The rotor consists of a carrying the conductor. Speed of induction motor: Ns= 120 f / p Ns=synchronous speed of stator P= the no. poles F= supply in freq. Controlling of 1-phase motor through auto transformer: Two or more contactors may be used to provide reduced voltage starting of a motor. By using an auto-transformer or a series inductance, a lower voltage is present at the motor terminals, reducing starting torque and inrush current. Once the motor has come up to some fraction of its full-load speed, the starter switches to full voltage at the motor terminals. Since the autotransformer or series
  • 13. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 13 reactor only carries the heavy motor starting current for a few seconds, the devices can be much smaller compared to continuously rated equipment. The transition between reduced and full voltage may be based on elapsed time, or triggered when a current sensor shows the motor current has began to reduce. Circuit Diagram:- Figure Figure:- Precaution:- 1. Connection should be proper. Loose connection is not allowed. 2. Do not touch any live wire or part.
  • 14. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 14 3. Before switch on the supply, the connection should be checked by lab assistant. 4. Do not damage the terminals of part or wire etc. Procedure:- 1. Make connectiondiagram as shown in fig 3.1. 2. Put input voltage at “zero”. 3. Now slowly vary input voltage and measure the speed by Tachometer. 4. Record the value of speed at various voltages. Observation Table:- S.No Input voltage (volt.) Speed(rpm) 1. 50V 2. 100V 3. 150V 4. 200V 5. 230V Calculations:- Results:- Thus we have prepare the connection and working principal of single phase induction motor through 1-phase auto transformer and got the speed regulation with varying the input voltage. References:- 1. O P Arora: Power Electronics Laboratory-Experiments and Organization, Narosa Pub. 2. P B Zbar: Industrial Electronics- A Text-Lab Manual, Tata McGraw Hill
  • 15. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 15 Viva- Voice:- Que.1) What is the type of induction motor? Que.2) What is the speed of induction motor? Que.3) What is an auto- transformer? Que.4) What is the function of speed regulator? Que.5) Which typr of induction motor is self start?
  • 16. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 16 EXPERIMENT NO. 4 Aim:- Prepare the connection of 3-phase squirrel cage induction motor through 3-phase auto transformer and vary the speed. Apparatus Required:- S. No. Name Type Range /Rating Quantity 1 3- phase induction Motor Squirrel-cage 230V, 1 or 2HP, 1500 RPM 50Hz 1 2 Volt meter M I (0-600V)/(0-300V) 1/1 3 Ammeter M I 2A/5A 1/1 4 Auto transformer 1-phase 230V/(0-270V) 1 5 Tachometer Digital 0-2000rpm 1 6 Wattmeter Dynamometer 10/20A, 300/600V, 1800/2000W 2 Theory:- 3-Induction Motors: An induction or asynchronous motor is a type of AC motorare widely used in industrial and commercial application. They are classified either as squirrel cage. These motor are self starting and use no capacitor, start winding, centrifugal switch or other starting device. They produce medium to high degrees of starting torque. The power capabilities and efficiency in these motors range from medium to high compared to their 1- phase counter parts. Popular application include grinders, lathes etc. Squirrel cage:- Almost 90%of 3-phase ac induction motors are use of this type. The rotor is of the squirrel cage type and its work as explained earlier. The power rating range from one-third to several hundredhorsepower. Motor of this type, rated one horsepower or larger, cost and can start heavier loads than their 1-phase.
  • 17. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 17 Stator: The stator is made of the several tin lamination of aluminium or cast iron.they are punched and clamped together to form a hollow cylinder.coils of insulation wires are inserted in to these slots. Each grouping of coils , together with the core it surround , forms an electromagnet on the application of ac supply. Rotor: These are made of several thin steel lamination with evenly spaced bars, which are made up of aluminium or copper , along the periphery. In the most popular type of rotor, these bars are connected at ends mechanically and electrically by the use of rings.The rotor consists of a carrying the conductor. Speed of induction motor: Ns= 120 f / p Ns=synchronous speed of stator P= the no. poles F= supply in freq. Basic operation: In Induction motor, the stator is powered with alternating current (poly phase in large machines) and designed to create a rotating magnetic field which rotates in time with the AC oscillations. In an induction motor the rotor rotates at a slower speed than the stator field. Therefore the magnetic field through the rotor is changing (rotating). The rotor has windings in the form of closed loops of wire. The rotating magnetic flux induces currents in the windings of the rotor as in a transformer. According to Lenz's law the rotor windings will try to oppose the cause of production of induced current in the rotor. The cause of induced current in the rotor is the rotating stator magnetic field, so to oppose this the rotor will start to rotate in the direction of the rotating stator magnetic field to make the relative speed between rotor and rotating stator magnetic field zero, thus the motor will start. For these currents to be induced, the speed of the physical rotor must be lower than that of the stator's rotating magnetic field ( ), or the magnetic field would not be moving relative to the rotor conductors and no currents would be induced. As the speed of the rotor drops below synchronous
  • 18. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 18 speed, the rotation rate of the magnetic field in the rotor increases, inducing more current in the windings and creating more torque. The ratio between the rotation rate of the magnetic field as seen by the rotor (slip speed) and the rotation rate of the stator's rotating field is called "slip". Under load, the speed drops and the slip increases enough to create sufficient torque to turn the load. For this reason, induction motors are sometimes referred to as asynchronous motors. An induction motor can be used as induction generator, or it can be unrolled to form the linear induction motor which can directly generate linear motion. Controlling of 3-phase motor through auto transformer: Two or more contactors may be used to provide reduced voltage starting of a motor. By using an auto-transformer or a series inductance, a lower voltage is present at the motor terminals, reducing starting torque and inrush current. Once the motor has come up to some fraction of its full-load speed, the starter switches to full voltage at the motor terminals. Since the autotransformer or series reactor only carries the heavy motor starting current for a few seconds, the devices can be much smaller compared to continuously rated equipment. The transition between reduced and full voltage may be based on elapsed time, or triggered when a current sensor shows the motor current has began to reduce. Circuit Diagram:- Figure Precaution:- 1. Connection should be proper. Loose connection is not allowed.
  • 19. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 19 2. Do not touch any live wire or part. 3. Before switch on the supply, the connection should be checked by lab assistant. 4. Do not damage the terminals of part or wire etc. Procedure:- 1. Makeconnection diagram as shown in fig. 2. Put input voltage at “zero”. 3. Now slowly vary input voltage and measure the speed by Tachometer. 4. Record the value of speed at various voltages. Observation Table:- S.No. Input voltage (volt.) Speed(rpm) Current( I) Wattmeter W1 (P1) Wattmeter W2 ( P2) 1. 2. 3. 4. 5. Calculations:- Results:- Thus we have successfully prepare the connection and study of operation of 3- phase squirrel cage induction motor and controlled the speed of induction motor by varying input voltage.
  • 20. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 20 References:- 1. O P Arora: Power Electronics Laboratory-Experiments and Organization, Narosa Pub. 2. P B Zbar: Industrial Electronics- A Text-Lab Manual, Tata McGraw Hill Viva- Voice:- Que.1) What do you mean by 1 HP? Que .2) How does rotation of 3-phase induction motor reversed? Que.3) Why the stator of an induction motor is laminated? Que 4) Why squirrel cage induction better than slip ring induction motor? Que-5) What is the phase displacement in space between two windings of single phase induction motor?
  • 21. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 21 EXPERIMENT NO. 5(A) Aim:- Prepare the connection and testing of a fluorescent tube light. Apparatus Required:- S. No. Name Range Quantity 1 Fluorescent tube 40W, 230V, 50Hz, 120cm 1 2 Choke coil 40W,230V, Cos φ=0.5 1 3 Starter Glow type for 20/40/65/80W tube 2 4 Test lamp 15W/100W/200W 1/1/1 5 Connecting leads -------- As per required Theory:- A fluorescent lamp is a gas-discharge lamp that uses electricity to excitemercuryvapor. The excited mercury atoms produce short-wave ultraviolet light that then causes a phosphor to fluoresce, producing visible light. A fluorescent lamp converts electrical power into useful light more efficiently than an incandescent lamp. Lower energy cost typically offsets the higher initial cost of the lamp. The lamp fixture is more costly because it requires a ballast to regulate the current through the lamp. A fluorescent lamp contains following parts:- Construction-: (1) Fluorescent tube (2) Choke or ballast (3) Starter s (1) Fluorescent tube-: A fluorescent lamp tube is filled with a gas containing low pressure mercury vapor and argon, xenon, neon, or krypton. The pressure inside the lamp is around 0.3% of atmospheric pressure. The
  • 22. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 22 inner surface of the bulb is coated with a fluorescent (and often slightly phosphorescent) coating made of varying blends of metallic and rare-earthphosphor salts. The bulb's electrodes are typically made of coiled tungsten and usually referred to as cathodes because of their prime function of emitting electrons. For this, they are coated with a mixture of barium, strontium and calcium oxides chosen to have a low thermionic emissiontemperature. Compact fluorescent lamps have several small-diameter tubes joined in a bundle of two, four, or six, or a small diameter tube coiled into a spiral, to provide a high amount of light output in little volume. (2) Choke or ballast-: Instant start ballast starts lamps without heating the cathodes at all by using high voltage (around 600 V). It is the most energy efficient type, but gives the least number of starts from a lamp as emissive oxides are blasted from the cold cathode surfaces each time the lamp is started. This is the best type for installations where lamps are not turned on and off very often. Rapid start ballast applies voltage and heats the cathodes simultaneously. It provides superior lamp life and more cycle life, but uses slightly more energy as the cathodes in each end of the lamp continue to consume heating power as the lamp operates. A dimming circuit can be used with dimming ballast, which maintains the heating current while allowing lamp current to be controlled. Programmed-start ballast is a more advanced version of rapid start. This ballast applies power to the filaments first, then after a short delay to allow the cathodes to preheat, applies voltage to the lamps to strike an arc. This ballast gives the best life and most starts from lamps, and so is preferred for applications with very frequent power cycling such as vision examination rooms and restrooms with a motion detector switch.
  • 23. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 23 Fig. ballast Starter-: The automatic glow starter shown in the photograph to the left consists of a small gas-discharge lamp, containing neon or argon in parallel with a normally-open bi-metallicswitch. It functions as a time-delay switch, turning the filaments of the fluorescent tube on for a few seconds to start it, and then turning them off. When power is first applied to the circuit, a glow discharge will appear over the electrodes in the starter lamp. This glow discharge will heat the gas in the starter and cause the bi-metallic contact to bend towards the other contact. When the contacts touch, the two filaments of the fluorescent lamp and the ballast will effectively be switched in series to the supply voltage. The current through the filaments causes them to heat up and emit electrons into the tube gas by thermionic emission Starter Connection and working of fluorescent lamp-: Connection of fluorescent lamp is shown in the fig (a). In this connection one pin of both side is connected with starter’s terminals separately
  • 24. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 24 Fig (a) connection of fluorescent lamp When the light is turned on, the electric power heats up the cathode enough for it to emit electrons (thermionic emission). These electrons collide with and ionize noble gas atoms inside the bulb surrounding the filament to form a plasma by the process of impact ionization. As a result of avalanche ionization, the conductivity of the ionized gas rapidly rises, allowing higher currents to flow through the lamp. The fill gas helps determine the operating electrical characteristics of the lamp, but does not give off light itself. The fill gas effectively increases the distance that electrons travel through the tube, which allows an electron a greater chance of interacting with a mercury atom. Argon atoms, excited to a metastable state by impact of an electron, can impart this energy to a neutral mercury atom and ionize it, described as the Penning effect. This has the benefit of lowering the breakdown and operating voltage of the lamp, compared to other possible fill gases such as krypton. Circuit Diagram:- Figure
  • 25. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 25 ADVANTAGE:- 1. Longer life of about 7500 working hours. 2. High efficiency about 40 lumes/watt. 3. It is economical in use in long run. 4. Available in different colors. DISADVANTAGE:- 1. Its initial cost is too high. 2. Fixing of its accessories takes time. 3. Its power factor is low. Precaution:- 1. Connection should be proper. Loose connection is not allowed. 2. Do not touch any live wire or part. 3. Before switch on the supply, the connection should be checked by lab assistant. 4. Do not damage the terminals of part or wire etc. Procedure:- 1. Make the connection as per as diagram. 2. Connections check and give the supply. 3. When lamp does not glow then filament open. 4. When lamp bright glow then filament is short. 5. When dim glow then filament is in proper working condition. Observation Table:- S.No. Test For Test Result 1. Choke coil 2. starter 3. Tube light 4. Fluorescent tube
  • 26. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 26 Calculations:- Results:- we have successfully connection and study of fluorescent lamp and testing of testing of its various parts has been done. References:- 1. O P Arora: Power Electronics Laboratory-Experiments and Organization, Narosa Pub. 2. P B Zbar: Industrial Electronics- A Text-Lab Manual, Tata McGraw Hill Viva- Voice:- Que .1) Filament of lamp is made by….? Que 2) What is the use of inert gas in lamps? Que3) Why filament is in coil shape? Que -4) What is the composition of inert gases used in filament lamp? Que.-5)What is life of approx. incandesend lamp?
  • 27. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 27 EXPERIMENT NO. 5(B) Aim:- To prepare the connection of halogen lamp and measure voltage and current. Apparatus Required:- S.No. Name Range Qty 1. Copper ballast 220-240V,1A, P.F.=0.5 1 2. Capacitor 250V, 10 MICRO FARAD 1 3. DPMCB 6A, 250V 1 4. Helogen lamp 500W, 250V 1 5. Helogen lamp holder 5A 1 Theory:- The halogen lamp is the latest member in the family of incandescent lamp. It numerous advantages over the ordinary incandescent lamp. As already stated the life and efficiency of an incandescent lamp fall of with use-partly due to slow evaporation of the filament and partly due to back deposit formed on the inside of the inside of the bulb. The addition of small amount of halogen vapours to the filling gas restores port of the evaporated tungsten vapour back to filament by means of chemical reaction i.e. there is a sort of regeneration cycle. Advantage:- 1. No dimensions of lamp miniature size. 2. Long life-20000 hours. 3. Better colour rendition. Application:- Halogen lamp (up to 5 KW) – Playing Field, Large Garden,Car Parking, T.V. , Studio Etc.
  • 28. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 28 Circuit Diagram:- Figure:- Precaution:- 1. Connection should be proper. Loose connection is not allowed. 2. Do not touch any live wire or part. 3. Before switch on the supply, the connection should be checked by lab assistant. 4. Do not damage the terminals of part or wire etc. Procedure:- 1. Make the connection as per as diagram. 2. Connections check and give the supply. 3. When lamp does not glow then filament open. 4. When lamp bright glow then filament is short. 5. When dim glow then filament is in proper working condition. Observation Table:- S.No Switch Condition Voltage(v) Current(I) 1. S1 On 2. S1 Off
  • 29. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 29 Calculations:- Results:- we have successfullyprepare the connection and study of halogen lamp and measure voltage and current. References:- 1. O P Arora: Power Electronics Laboratory-Experiments and Organization, Narosa Pub. 2. P B Zbar: Industrial Electronics- A Text-Lab Manual, Tata McGraw Hill Viva- Voice:- Ques 1.)Why halogen lamp popular than other lamps? Ques 2.) What is diff. b/w resistivity and specific resistance? Ques 3.)What do you mean by resistor? Que -4) What is the composition of inert gases used in filament lamp? Que.-5) What is life of approx. incandesend lamp?
  • 30. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 30 EXPERIMENT NO. 5(C) Aim:- To prepare the connection of sodium vapour lamp and measure voltage and current. Apparatus Required:- S.No Name Range QTY. 1. Hpsv lamp 220-250V,70W 1 2. Hpsv lamp holder 5A 1 3. Copper ballast 220-240V,1A, P.F.=0.34 1 4. Igniter 20000V 1 5. Capacitor 250V,10 MICRO FARAD 1 6. DPMCB 6A, 250V 1 7. Leads RED,BLACK,YELLOW 1 Theory:- The practically lamp of this development of this type of lamp, however was delayed since ordinary glass cannot with stand the chemical action of hot sodium. The sodium vapour lamp consists of bulbs containing a small amount of metallic sodium,to develop enough heat to vaporize the sodium.Since long discharge paths are necessary therefore, the discharge envelope is usually bent into u-shape. The lamp operates at temp. 300 degree temp in order to conserve the heat generate and assure the lamp operating at normal air temp. The discharge envelope is closed in a special vacuum envelop designed for this purpose. The lamp must be operated horizontally or nearly so, to keep the sodium well spread out along the tube, although some small lamp, may be operated vertically lamp up. The sodium vapour lamp is only suitable for alternate current and therefore requires chocke control. This requirement is met by operating the lamp for a stray field step-up-tapped auto transformed auto transformed with an open circuit secondary voltage of 470-480 volts. The uncorrected power factor is very low.
  • 31. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 31 When is not in operation , the sodium is usually in the form of solid deposited on the side walls of tube, therefore at first when it is connected across the supply mains, the discharge takes places in the neon gas. The metallic sodium vaporizes and then ionizes. The efficiency of a sodium vapour lamp under practically condition is about 40-50 lumens/watt. The major application of this type of lamp is for high way and generator outdoor lighting where colour discrimination is not required, as required, such as street lighting parks , rail yards,lamps are manufactured in 45,60,85and is not affected by voltage variation at the end of this period the light output will be reduced by 15% due to ageing. Advantage:- 1. No dimensions of lamp miniature size. 2. Long life-20000 hours. 3. Better colour rendition. Circuit Diagram:- Figure.
  • 32. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 32 Precaution:- 1. Connection should be proper. Loose connection is not allowed. 2. Do not touch any live wire or part. 3. Before switch on the supply, the connection should be checked by lab assistant. 4. Do not damage the terminals of part or wire etc. Procedure:- 1. Make the connection as per as diagram. 2. Connections check and give the supply. 3. When lamp does not glow then filament open. 4. When lamp bright glow then filament is short. 5. When dim glow then filament is in proper working condition. Observation Table:- S.No Switch Condition Voltage(v) Current(I) 1. S1 on 2. S1 off Calculations:- Results:- we have successfully connection and study of Sodium vapour lamp with measure the voltage and current. References:- 1. O P Arora: Power Electronics Laboratory-Experiments and Organization, Narosa Pub. 2. P B Zbar: Industrial Electronics- A Text-Lab Manual, Tata McGraw Hill
  • 33. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 33 Viva- Voice:- Que.1.) What is the function of ignitor in sodium vapour lamps? Que.2) What is life and efficiency of SV lamps? Que3.)How much time taken by sodium vapour lamp to full glow? Que -4) What is the composition of inert gases used in filament lamp? Que.-5) What is life of approx. incandesend lamp?
  • 34. Stani Memorial College of Engineering And Technology, Phagi Electrical Engineering 108 Electrical And Electronics Engineering Lab Manual 34 Dear Sir, I am writing this letter to submit my request to release me from lecturer till 30-June-2014 with Stani Memorial College of Engineering and Technology, Jaipur. Though was enjoying working with this professional environment of SMCET but some compulsive circumstances made me take this action. Thank you for all of the support you and the college community have given me. I will never forget your generosity and the important skill. I will forever cherish the time I spent with my students, colleagues, and this community. I will be sure to complete all grading and associated responsibilities before departing this position. Please let me know what further steps or duties must be completed before my departure. I hope to stay in touch with you and our community. Thank you again for all of your support.