SlideShare a Scribd company logo
1 of 17
Download to read offline
www.raisecom.com

ISCOM2110EA-MA (REV.A) User Manual
Legal Notices
            Raisecom Technology Co., Ltd makes no warranty of any kind with regard to this manual,
            including, but not limited to, the implied warranties of merchantability and fitness for a particular
            purpose. Raisecom Technology Co., Ltd shall not be held liable for errors contained herein or direct,
            indirect, special, incidental or consequential damages in connection with the furnishing, performance,
            or use of this material.


Warranty.

            A copy of the specific warranty terms applicable to your Raisecom product and replacement parts
            can be obtained from Service Office.


Restricted Rights Legend.

            All rights are reserved. No part of this document may be photocopied, reproduced, or translated to
            another language without the prior written consent of Raisecom Technology Co., Ltd. The
            information contained in this document is subject to change without notice.


Copyright Notices.


            Copyright ©2011 Raisecom. All rights reserved.

            No part of this publication may be excerpted, reproduced, translated or utilized in any form or by any
            means, electronic or mechanical, including photocopying and microfilm, without permission in
            Writing from Raisecom Technology Co., Ltd.


Trademark Notices


                        is the trademark of Raisecom Technology Co., Ltd.

            Java™ is a U.S. trademark of Sun Microsystems, Inc.

            Microsoft® is a U.S. registered trademark of Microsoft Corporation.

            Windows NT® is a U.S. registered trademark of Microsoft Corporation.

            Windows® 2000 is a U.S. registered trademark of Microsoft Corporation.

            Windows® XP is a U.S. registered trademark of Microsoft Corporation.

            Windows® and MS Windows® are U.S. registered trademarks of

            Microsoft Corporation.
Contact Information
Technical Assistance Center

           The Raisecom TAC is available to all customers who need technical assistance with a Raisecom
           product, technology, or, solution. You can communicate with us through the following methods:




           Address:        Building 2, No. 28 of the Shangdi 6th Street, Haidian District, Beijing 100085

           Tel:           +86-10-82883305

           Fax:           +86-10-82883056




World Wide Web

           You can access the most current Raisecom product information on the World Wide Web at the
           following URL:
           http://www.raisecom.com




Feedback

           Comments and questions about how the ISCOM2110EA-MA (REV.A) device works are welcomed.
           Please review the FAQ in the related manual, and if your question is not covered, send email by
           using the following web page:
           http://www.raisecom.com/en/contact-us.html.

           If you have comments on the ISCOM2110EA-MA (REV.A) specification, instead of the web page
           above, please send comments to:

           export@raisecom.com



           We hope to hear from you!
CONTENTS
Chapter 1        Overview ------------------------------------------------------------------------------------ 1
   1.1     Contents ---------------------------------------------------------------------------------------------------------------- 1
   1.2     Terminology explanation --------------------------------------------------------------------------------------------- 1
Chapter 2        Technical Specifications --------------------------------------------------------------- 2
   2.1     Hardware description------------------------------------------------------------------------------------------------- 2
   2.2     Dimension of the device --------------------------------------------------------------------------------------------- 2
   2.3     Working environment------------------------------------------------------------------------------------------------- 2
Chapter 3        Device Appearance And Description----------------------------------------------- 3
   3.1     Front panel and explanation ---------------------------------------------------------------------------------------- 3
   3.2     Rear panel and explanation ---------------------------------------------------------------------------------------- 3
Chapter 4        Installation And Connection ---------------------------------------------------------- 5
   4.1     Device models --------------------------------------------------------------------------------------------------------- 5
   4.2     Device installation ----------------------------------------------------------------------------------------------------- 5
         4.2.1   Installation environment ----------------------------------------------------------------------------------------------------------- 5
         4.2.2   Install onto the rack ---------------------------------------------------------------------------------------------------------------- 5
   4.3     Connection of switch ------------------------------------------------------------------------------------------------- 5
         4.3.1   Connect to CONSOLE------------------------------------------------------------------------------------------------------------- 5
         4.3.2   Connect to Ethernet ---------------------------------------------------------------------------------------------------------------- 7
         4.3.3   Connect to power supply---------------------------------------------------------------------------------------------------------- 7
   4.4     Making cable ----------------------------------------------------------------------------------------------------------- 7
   4.5     Power supply----------------------------------------------------------------------------------------------------------- 8
Chapter 5        Precautions -------------------------------------------------------------------------------- 9
Preface
About This Manual
               This manual is applicable to ISCOM2110EA-MA switch VER A.00 or higher version.



Who Should Read This Manual
               This manual is a valuable reference for sales and marketing staff, after service staff and
               telecommunication network designers. For those who want to have an overview of the features,
               applications, structure and specifications of ISCOM2110EA-MA device, this is also a recommended
               document.



Relevant Manuals
               ISCOM2110EA-MA Commands Notebook

               ISCOM2110EA-MA Configuration Guide



Organization
               This manual is an introduction of the main functions of ISCOM2110EA-MA. To have a quick grasp
               of the using of ISCOM2110EA-MA, please read this manual carefully. The manual is composed of
               the following chapters:

               Chapter 1 Overview
               This chapter briefly introduces the content referred in this manual, reference documents and
               terminology explanations

               Chapter 2 Dimensions
               This chapter mainly introduces the hardware introduction and device dimensions.

               Chapter 3 Device Appearance And Description
               This chapter introduces the appearance of device and indicators description.

               Chapter 4 Installation and Connection
               This chapter introduces the device installation and connection.

               Chapter 5 Precautions
General Safety Instructions
                The following instructions serve as a general guide for the safe installation and operation of
                telecommunications products. Additional instructions, if applicable, are included inside the manual.


Safety Symbols

                               This symbol may appear on the equipment or in the text. It indicates potential safety
                               hazards regarding product operation or maintenance to operator or service personnel.




                               Danger of electric shock! Avoid any contact with the marked surface while the
                               product is energized or connected to outdoor telecommunication lines.


                               Protective earth: the marked lug or terminal should be connected to the building
                               protective earth bus.
                               Some products have terminals which are permanently protective earthing conductors.
                               Please be sure well connected to earthing before equipment connected to supply.

                                Some products may be equipped with a laser diode. In such cases, a label with the
                                laser class and other warnings as applicable will be attached near the optical
                                transmitter. The laser warning symbol may be also attached.
                                Please observe the following precautions:
                                • Before turning on the chassis with optic module, make sure that the fiber optic
                                cable is intact and is connected to the transmitter.
                 • Do not attempt to adjust the laser drive current.
                 • Do not use broken or unterminated fiber-optic cables/connectors or look straight at the laser beam.
                 • The use of optical devices with the equipment will increase eye hazard.
                 • Use of controls, adjustments or performing procedures other than those specified herein, may
                 result in hazardous radiation exposure.
                 ATTENTION: The laser beam may be invisible!

                Always observe standard safety precautions during installation, operation and maintenance of this
                product. Only qualified and authorized service personnel should carry out adjustment, maintenance
                or repairs to this product. No installation, adjustment, maintenance or repairs should be performed by
                either the operator or the user.

                Some products have more than one power supply cord. Disconnect 2 power supply cords before
                servicing to avoid electric shock.

                Before operating modules in the electricity conditions, please be noticed that optical modules shall
                be connected with optical fiber wires or shield with optical module cover for fear that laser light
                harms to operator’s eyes.

                It is suggested to apply optical module CLASS1 as laser.


Handling Energized Products
General Safety Practices
                Do not touch or tamper with the power supply when the power cord is connected. Line voltages may
                be present inside certain products even when the power switch (if installed) is in the OFF position or
a fuse is blown. For DC-powered products, although the voltages levels are usually not hazardous,
              energy hazards may still exist.
              Before working on equipment connected to power lines or telecommunication lines, remove jewelry
              or any other metallic object that may come into contact with energized parts.
              Unless otherwise specified, all products are intended to be grounded during normal use. Grounding
              is provided by connecting the mains plug to a wall socket with a protective earth terminal. If an earth
              lug is provided on the product, it should be connected to the protective earth at all times, by a wire
              with a diameter of 18 AWG or wider. Rack-mounted equipment should be mounted only in earthed
              racks and cabinets.
              Always make the ground connection first and disconnect it last. Do not connect telecommunication
              cables to ungrounded equipment. Make sure that all other cables are disconnected before
              disconnecting the ground.
Connection of AC Mains
              Make sure that the electrical installation complies with local codes.
              Always connect the AC plug to a wall socket with a protective ground.
              Always connect the power cord first to the equipment and then to the wall socket. If a power switch
              is provided in the equipment, set it to the OFF position. If the power cord cannot be readily
              disconnected in case of emergency, make sure that a readily accessible circuit breaker or emergency
              switch is installed in the building installation.
Connection of DC Mains
              Unless otherwise specified in the manual, the DC input to the equipment is floating in reference to
              the ground. Any single pole can be externally grounded.
              Due to the high current capability of DC mains systems, care should be taken when connecting the
              DC supply to avoid short-circuits and fire hazards.
              DC units should be installed in a restricted access area, i.e. an area where access is authorized only to
              qualified service and maintenance personnel.
              Make sure that the DC supply is electrically isolated from any AC source and that the installation
              complies with the local codes.
              Before connecting the DC supply wires, ensure that power is removed from the DC circuit. Locate
              the circuit breaker of the panel board that services the equipment and switch it to the OFF position.
              When connecting the DC supply wires, first connect the ground wire to the corresponding terminal,
              then the positive pole and last the negative pole. Switch the circuit breaker back to the ON position.
              A readily accessible disconnect device that is suitably rated and approved should be incorporated in
              the building installation.

Preventing Electrostatic Discharge Damage
              Modules which can be plugged into chassis are sensitive to damage from static electricity.
              Conversely, static voltages as high as 35,000V can be generated just by handling plastic or foam
              packing material, or by sliding assemblies across plastic and carpets. Not exercising the proper
              electrostatic discharge (ESD) precautions can result in intermittent or complete component failures.
              To minimize the potential for ESD damage, observe the following guidelines:
              • Always use an ESD-preventive antistatic wrist strap or ankle strap and ensure that it makes good
              skin contact.
              • When removing or installing a component, make sure the equipment end of your antistatic strap
              leash is connected to the ESD connection sockets on the front of the chassis or to a bare metal
              surface on the chassis. Avoid contact between the component and your clothing. The wrist strap only
              protects the component from ESD voltages on the body; ESD voltages on your clothing can still
              cause component damage.
              • Always place a card component-side-up on an antistatic surface, in an antistatic card rack, or in a
              static shielding bag. If you are returning the item to the factory, immediately place it in a static
              shielding bag.
              • Handle Modules by the metal card carrier edges only; Avoid touching the board or any connector
              pins.
www.raisecom.com                                                                                     User Manual




                                          Chapter 1 Overview



1.1 Contents
                   This manual describes how to install ISCOM2110EA-MA Switch, the features and component
                   modules of the device and functions of every module. It provides a standard method of installation
                   and cable specifications.

                   This manual is for hardware installation and for additional configuration operations of software,
                   refers to Configuration Guide.



1.2 Terminology explanation
           10BASE-T          Brief terminology of IEEE 802.3 f or LANs, operates at 10Mbps based on
                             Manchester coding and uses category-3 or better twisted-pair cable.
          100BASE-TX         Brief terminology of IEEE 802.3 f or LANs, operates at 100Mbps based on
                             4B/5B coding and uses category-5 twisted-pair cable.
          1000 Base-T        Refer to normal standard of IEEE 802.3, providing PAM5X5 signal codes, 4
                             pairs of 100Ω CAT-5 UTP transmission, data transmitting speed up to 1Gbit/s
                             Refer to normal standard of IEEE 802.3, Ethernet technology over optical
          1000BASE-X         fiber, generally refer to below concept in this document:
                             1000BaseSX Multi-mode Fiber 500 m
                             1000BaseLX Single-mode Fiber 3000 m
                             Brief terminology of IEEE 802.3, fast Ethernet technology that uses optical
          100BASE-FX
                             fiber, single-mode and multi-mode fiber (62.5 and 125um available)
                             connecting distance up to 550 meters.
                             Auto-Negotiation detects the various modes that exist in the device on the
        Auto-negotiation
                             other end of the wire, the Link Partner, and advertises its own abilities to
                             automatically configure the highest performance mode of interoperation.
           Full-duplex       Transmission of data in two directions simultaneously
                             Data can be transmitted in both Rx and Tx directions on a signal carrier, but
          Half-duplex
                             not at the same time.
             RJ-45           An eight-wire connector used in twister pair wire
              MDI            Medium dependent interface, provides the physical and electrical connection to
                             the cabling medium.
             MDIX            MDI crossover, a version of MDI that enables connection between like devices.




                                                                                                        1
www.raisecom.com                                                                                   User Manual




                               Chapter 2 Technical Specifications



2.1 Hardware description
                   ISCOM2110EA-MA is professional layer-2 Ethernet switch to provide core or access switching for
                   enterprises, residence community and school, etc. It provides 8 10/100Base-TX Ethernet electrical
                   ports and 2 COMBO ports (100Base-FX and 1000Base-X compatible for SFP port,
                   10/100/1000Base-T for electrical port), the power of system is smaller than 10W, no fan inside.



2.2 Dimension of the device
                   Dimension of ISCOM2110EA-MA is: 1U (H)* 260mm (W)* 130mm (D), weighted 1.17kg; it can be
                   installed in 19-inch rack or put on the table.



2.3 Working environment
                         Environment temperature: 0° ~ 45°
                         Storage temperature: - 25° ~ 65°
                         Environment humidity: 10%~90%




                                                                                                      2
www.raisecom.com                                                                                     User Manual




                       Chapter 3 Device Appearance And Description



3.1   Front panel and explanation
                   The company logo and device model are located on the front panel of device, as figure shows below:




3.2   Rear panel and explanation
                   On the rear panel of ISCOM2110EA-MA, there are 8 10/100M Ethernet electrical ports, 2 COMBO
                   ports, status indicator LEDs and power supply interfaces. AC and DC power supply are of different
                   interfaces, see in the following figures:

            1      2                     3              4                    5      6     7          8       9




                                                  AC power supply




                                                  DC power supply

                   Description of the device panel:

                   1. 2 indicators for device status, SYS and PWR (marked as number 8 on the panel), definition of the
                   LED:


                                                                                                         3
www.raisecom.com                                                                                      User Manual

                        Indicator         Color    Status                 Indication

                                                     ON        System is initializing at the very
                                                                beginning of power on device
                           SYS            Green   Flickering       System works normally
                                                    OFF                Software fault.
                                                     ON              System powered on
                           PWR            Green
                                                    OFF              System powered off

                   2. The 8 10/100M Ethernet electrical interfaces (marked as number 4 on panel) and related indicators
                   (marked as nubmer 3), 1 indicator for each port, defined as LNK/ACT:

                        Indicator         Color     Status                Indication
                                                     ON            The interface is Link up
                        LNK/ACT           Green   Flickering    The interface is transmitting or
                                                                       receiving signal
                                                     OFF         The interface is Link down

                   3. The 2 C OMBO interfaces, including SFP optical port (marked as number 6) and electrical port
                   (marked as number 7). 1 i ndicator (marked as number 5) for each COMBO interface, defined as
                   LNK/ACT:

                        Indicator         Color     Status                Indication
                                                     ON            The interface is Link up
                        LNK/ACT           Green   Flickering    The interface is transmitting or
                                                                       receiving signal
                                                     OFF         The interface is Link down

                   4. The CONSOLE interface, locating on the right side of panel (marked as number 9).

                   5. Other interfaces:
                   Number 1: place for safety grounding bolt;

                   Number 2: interface for external power supply, 220V AC or -48V DC.




                                                                                                         4
www.raisecom.com                                                                                    User Manual




                            Chapter 4 Installation And Connection



4.1 Device models
                   The following device models are available now:

                        Model                                       Description
                               Ethernet Layer-2 switch, 8 10/100M Ethernet electrical ports,
             ISCOM2110EA-MA-AC
                               2 COMBO ports (100/1000M SFP optical port and
                               10/100/1000M Ethernet electrical port) and 1 Console port,
                               AC 220V power supply
                               Ethernet Layer-2 switch, 8 10/100M Ethernet electrical ports,
             ISCOM2110EA-MA-DC
                               2 COMBO ports (100/1000M SFP optical port and
                               10/100/1000M Ethernet electrical port) and 1 Console port,
                               DC -48V power supply
                               Ethernet Layer-2 switch, 8 10/100M Ethernet electrical ports,
             ISCOM2110EA-MA-WP
                               2 COMBO ports (100/1000M SFP optical port and
                               10/100/1000M Ethernet electrical port) and 1 Console port,
                               AC 220V or DC -48V power supply



4.2 Device installation
4.2.1 Installation environment
                   There are heat exhausting inlets at back and on both sides of ISCOM2110EA-MA. To maintain
                   ambient airflow there must be some space around the two sides or airflow path. The heat exhausting
                   inlets should not be blocked in case that the airflow can not flow.



4.2.2 Install onto the rack
                   Install the brackets onto the device and then fix the brackets on rack by the screws to make the
                   device as stable as possible.



4.3 Connection of switch
4.3.1 Connect to CONSOLE
                   ISCOM2110EA-MA provides RS-232C port in form of RJ45 as CONSOLE port. Connect the
                   CONSOLE port to PC serial port by cable, then configure and control the device through the PC
                   control platform.

                                Signal definition of CONSOLE port

                   ISCOM2110EA-MA provides CONSOLE port in form of RJ45, the pin number of RJ45 plug and
                   connector are showing as follows:



                                                                                                       5
www.raisecom.com                                                                              User Manual




                   Signaling and Pinouts of ISCOM2128EA-MA CONSOLE port:

                                  Pin number            Signal              Type
                                        3               RxD                  In
                                        6               TxD                 Out
                                       4, 5             GND
                                    1 ,2 ,7 ,8           N.C

                                Signaling and Pinouts of PC serial port:




                      Pin No.       Signal       Type            Pin No.     Signal    Type
                         1          DCD                            6          DSR
                         2          RxD            In              7          RTS
                         3           TxD          Out              8          CTS
                         4          DTR                            9              RI
                         5          GND

                                CONSOLE connection and parameters:




                                  PC serial interface     I      SCOM2110EA-MA CONSOLE

                   Parameters of simulation program on PC terminal are as follows:

                         Baud rate – 9600 bps
                         Data bit– 8
                         Stop bit– 1
                         Parity– None
                         Flow control– None




                                                                                                6
www.raisecom.com                                                                                     User Manual

4.3.2 Connect to Ethernet
                   ISCOM2110EA-MA provides 8 10/100M auto-negotiation Ethernet electrical ports and 2 1000M
                   COMBO uplink interfaces, it is available to configured as 1000M optical port, 100M optical port or
                   10/100/1000M electrical port.

                   The Ethernet electrical ports of ISCOM2110EA-MA have auto-MDI/MDIX function when
                   auto-negotiation enable. That is to say, the switch can perform MDI and MDIX signal switchover.
                   The device can communication in order regardless to the peer device adopts MDI or MDIX port,
                   straight-through or crossover network cable.

                   Pin number of RJ45 plug and connector is available in signal definition of CONSOLE port.
                            Signaling and Pinouts of MDI and MDIX are in the following table:
                                Pin No.        MDI-X signal             MDI signal
                                    1               RD+                    TD+
                                    2               RD-                    TD-
                                    3               TD+                    RD+
                                    6               TD-                    RD-
                                4 ,5 ,7 ,8          N.C                    N.C

                   The Ethernet ports of ISCOM2110EA-MA are MDI-X ports when disable auto-negotiation, and can
                   be connected to PC which has MDI port though straight-through cable.



4.3.3 Connect to power supply
                   Take the power wire in attachment to connect power interface of ISCOM2110EA-MA with 220V (or
                   -48V) power supply.

                   NOTE: The switch is powered on once user connect power supply interface by power wire, therefore,
                   please make sure the switch has been connected correctly before connecting power supply.



4.4 Making cable
                   Pin number of RJ45 plug and connector is available in signal Definition of CONSOLE port.

                                 Straight through cable (100M and 1000M straight through cable are identical)




                                                                                                        7
www.raisecom.com                                                                                   User Manual



                             100M crossover cable




                             1000M crossover cable




4.5 Power supply
                      After installing the device correctly following above steps, the device can be powered on by
                       connecting the switch with 220V or -48V power supply.
                      PWR indicator ON means the system has been powered on.
                      All the indicator lights on front panel of ON means the system is self-checking and
                       initializing.
                      After self-check and initialization, the device starts to operate, and then the SYS indicator
                       starts flickering which means that system operates normally. Indicator LEDs of the 24
                       Ethernet ports indicate the status of ports (ON or OFF is according to port configuration and
                       connection).
                      If the CONSOLE port is connected to PC and terminal software is configured correctly
                       before system powered on, there will be user management interface on the PC screen, and
                       then operation is available. (Specific operations are available in ISCOM2110EA-MA
                       Configuration Guide).




                                                                                                      8
www.raisecom.com                                                                                       User Manual




                                         Chapter 5 Precautions


                   Only trained and qualified personnel should install, maintain, or install the parts of
                   ISCOM2110EA-MA. The device must be installed in a place where temperature and humidity can be
                   controlled, meanwhile consider the electronic conductivity of surrounding materials. Extreme
                   moisture may result in short circuit, and if too dry there may be fire. So there must be a suitable
                   environment for the device.

                         The power supply must be grounded to discharge static.
                         There must be some space between device and the near electrical equipments.
                         We recommend that outside device routing intersect with live wire to avoid long paralleling.
                         Follow the guide strictly when installing.
                         Do not install the device when your hands are wet or with a lot of sweat.
                         Do not rebuild the device mechanically and electrically.




                                                                                                         9
Address: Building 2, No. 28 of the Shangdi 6th Street, Haidian District, Beijing Postcode:
100085 Tel: +86-10-82883305 Fax: +86-10-82883056 Email: export@raisecom.com
http://www.raisecom.com

More Related Content

What's hot

Aoc usas-l8i
Aoc usas-l8iAoc usas-l8i
Aoc usas-l8ilaonap166
 
Catalogue biến tần Siemens V20 - đại lý biến tần siemens v20
Catalogue biến tần Siemens V20 - đại lý biến tần siemens v20Catalogue biến tần Siemens V20 - đại lý biến tần siemens v20
Catalogue biến tần Siemens V20 - đại lý biến tần siemens v20namtrungcompany
 
Cambium network ptp 810 series 01 00 user guide
Cambium network ptp 810 series 01 00 user guideCambium network ptp 810 series 01 00 user guide
Cambium network ptp 810 series 01 00 user guideAdvantec Distribution
 
Collage Backup Power Supply Installation Guide
Collage Backup Power Supply Installation GuideCollage Backup Power Supply Installation Guide
Collage Backup Power Supply Installation GuideRonald Bartels
 
420 opi 24523400_en_1006
420 opi 24523400_en_1006420 opi 24523400_en_1006
420 opi 24523400_en_1006Toàn Huỳnh
 
Micromaster 420 operating instructions
Micromaster 420 operating instructionsMicromaster 420 operating instructions
Micromaster 420 operating instructionsDagobert Aldus
 
Vcm hardware manual-ford-eng
Vcm hardware manual-ford-engVcm hardware manual-ford-eng
Vcm hardware manual-ford-engBill Zhao
 
9600 0420 m2150 design guide issue 2.0.0.7
9600 0420 m2150 design guide issue 2.0.0.79600 0420 m2150 design guide issue 2.0.0.7
9600 0420 m2150 design guide issue 2.0.0.7John Rabidou
 
Collage 700 series Option Modules Installation Guide
Collage 700 series Option Modules Installation GuideCollage 700 series Option Modules Installation Guide
Collage 700 series Option Modules Installation GuideRonald Bartels
 
Atv312 programming manual
Atv312 programming manualAtv312 programming manual
Atv312 programming manualToàn Huỳnh
 
Plc MicroSmart manual of IDEC
Plc MicroSmart manual of IDECPlc MicroSmart manual of IDEC
Plc MicroSmart manual of IDECquanglocbp
 
Atv312 programming manual
Atv312 programming manualAtv312 programming manual
Atv312 programming manualgloche
 
Haier l26 f6 l32f6 l42f6 sm oficial (1)
Haier l26 f6 l32f6 l42f6 sm oficial (1)Haier l26 f6 l32f6 l42f6 sm oficial (1)
Haier l26 f6 l32f6 l42f6 sm oficial (1)flillud
 
Catalog biến tần Inovance MD310 - HPC
Catalog biến tần Inovance MD310 - HPCCatalog biến tần Inovance MD310 - HPC
Catalog biến tần Inovance MD310 - HPCCTY TNHH HẠO PHƯƠNG
 

What's hot (20)

Aoc usas-l8i
Aoc usas-l8iAoc usas-l8i
Aoc usas-l8i
 
Catalogue biến tần Siemens V20 - đại lý biến tần siemens v20
Catalogue biến tần Siemens V20 - đại lý biến tần siemens v20Catalogue biến tần Siemens V20 - đại lý biến tần siemens v20
Catalogue biến tần Siemens V20 - đại lý biến tần siemens v20
 
Bhb sicam ak_eng
Bhb sicam ak_engBhb sicam ak_eng
Bhb sicam ak_eng
 
Tài liệu hướng dẫn cài đặt biến tần Siemens Sinamic G120
Tài liệu hướng dẫn cài đặt biến tần Siemens Sinamic G120Tài liệu hướng dẫn cài đặt biến tần Siemens Sinamic G120
Tài liệu hướng dẫn cài đặt biến tần Siemens Sinamic G120
 
Cambium network ptp 810 series 01 00 user guide
Cambium network ptp 810 series 01 00 user guideCambium network ptp 810 series 01 00 user guide
Cambium network ptp 810 series 01 00 user guide
 
Collage Backup Power Supply Installation Guide
Collage Backup Power Supply Installation GuideCollage Backup Power Supply Installation Guide
Collage Backup Power Supply Installation Guide
 
420 opi 24523400_en_1006
420 opi 24523400_en_1006420 opi 24523400_en_1006
420 opi 24523400_en_1006
 
Micromaster 420 operating instructions
Micromaster 420 operating instructionsMicromaster 420 operating instructions
Micromaster 420 operating instructions
 
Vcm hardware manual-ford-eng
Vcm hardware manual-ford-engVcm hardware manual-ford-eng
Vcm hardware manual-ford-eng
 
9600 0420 m2150 design guide issue 2.0.0.7
9600 0420 m2150 design guide issue 2.0.0.79600 0420 m2150 design guide issue 2.0.0.7
9600 0420 m2150 design guide issue 2.0.0.7
 
Spam 20
Spam 20Spam 20
Spam 20
 
Ist280 mc424 r001
Ist280 mc424 r001Ist280 mc424 r001
Ist280 mc424 r001
 
Collage 700 series Option Modules Installation Guide
Collage 700 series Option Modules Installation GuideCollage 700 series Option Modules Installation Guide
Collage 700 series Option Modules Installation Guide
 
F7 user manual
F7 user manualF7 user manual
F7 user manual
 
Atv312 programming manual
Atv312 programming manualAtv312 programming manual
Atv312 programming manual
 
F199
F199F199
F199
 
Plc MicroSmart manual of IDEC
Plc MicroSmart manual of IDECPlc MicroSmart manual of IDEC
Plc MicroSmart manual of IDEC
 
Atv312 programming manual
Atv312 programming manualAtv312 programming manual
Atv312 programming manual
 
Haier l26 f6 l32f6 l42f6 sm oficial (1)
Haier l26 f6 l32f6 l42f6 sm oficial (1)Haier l26 f6 l32f6 l42f6 sm oficial (1)
Haier l26 f6 l32f6 l42f6 sm oficial (1)
 
Catalog biến tần Inovance MD310 - HPC
Catalog biến tần Inovance MD310 - HPCCatalog biến tần Inovance MD310 - HPC
Catalog biến tần Inovance MD310 - HPC
 

Viewers also liked

The Automation Revolution - RAD
The Automation Revolution - RADThe Automation Revolution - RAD
The Automation Revolution - RADqualisystems
 
Carrier ethernet-for-power-utilities-presentation
Carrier ethernet-for-power-utilities-presentationCarrier ethernet-for-power-utilities-presentation
Carrier ethernet-for-power-utilities-presentationNir Cohen
 
Juniper mpls best practice part 2
Juniper mpls best practice   part 2Juniper mpls best practice   part 2
Juniper mpls best practice part 2Febrian ‎
 
Juniper MPLS Tutorial by Soricelli
Juniper MPLS Tutorial by SoricelliJuniper MPLS Tutorial by Soricelli
Juniper MPLS Tutorial by SoricelliFebrian ‎
 
Mplswc2006 white paper-v1.1
Mplswc2006 white paper-v1.1Mplswc2006 white paper-v1.1
Mplswc2006 white paper-v1.1Sean Andersen
 
Carrier grade ethernet for power utilities - solution paper
Carrier grade ethernet for power utilities - solution paperCarrier grade ethernet for power utilities - solution paper
Carrier grade ethernet for power utilities - solution paperNir Cohen
 

Viewers also liked (8)

The Automation Revolution - RAD
The Automation Revolution - RADThe Automation Revolution - RAD
The Automation Revolution - RAD
 
Carrier ethernet-for-power-utilities-presentation
Carrier ethernet-for-power-utilities-presentationCarrier ethernet-for-power-utilities-presentation
Carrier ethernet-for-power-utilities-presentation
 
Juniper mpls best practice part 2
Juniper mpls best practice   part 2Juniper mpls best practice   part 2
Juniper mpls best practice part 2
 
Juniper MPLS Tutorial by Soricelli
Juniper MPLS Tutorial by SoricelliJuniper MPLS Tutorial by Soricelli
Juniper MPLS Tutorial by Soricelli
 
Mplswc2006 white paper-v1.1
Mplswc2006 white paper-v1.1Mplswc2006 white paper-v1.1
Mplswc2006 white paper-v1.1
 
MPLS Presentation
MPLS PresentationMPLS Presentation
MPLS Presentation
 
MPLS
MPLSMPLS
MPLS
 
Carrier grade ethernet for power utilities - solution paper
Carrier grade ethernet for power utilities - solution paperCarrier grade ethernet for power utilities - solution paper
Carrier grade ethernet for power utilities - solution paper
 

Similar to Iscom2110 ea ma(rev.a) user manual 201104

manualdeservicioXeroxDC250FullServiceManual.pdf
manualdeservicioXeroxDC250FullServiceManual.pdfmanualdeservicioXeroxDC250FullServiceManual.pdf
manualdeservicioXeroxDC250FullServiceManual.pdfluisgabrielcruz4
 
Panduan pelanggan fast net cable modem motorola sb5101
Panduan pelanggan fast net cable modem motorola sb5101Panduan pelanggan fast net cable modem motorola sb5101
Panduan pelanggan fast net cable modem motorola sb5101Thomas Ra Urus
 
Siemens micromaster-440-manual
Siemens micromaster-440-manualSiemens micromaster-440-manual
Siemens micromaster-440-manualAshok Kumar
 
NB Designer Manual Operation [unlockplc.com]
NB Designer Manual Operation [unlockplc.com]NB Designer Manual Operation [unlockplc.com]
NB Designer Manual Operation [unlockplc.com]unlockplc123
 
Msi k9 n_series_manual
Msi k9 n_series_manualMsi k9 n_series_manual
Msi k9 n_series_manualescuelaem
 
872444 an-01-en-motherboard joyit-amd1250_1_gb_250gb_pcs
872444 an-01-en-motherboard joyit-amd1250_1_gb_250gb_pcs872444 an-01-en-motherboard joyit-amd1250_1_gb_250gb_pcs
872444 an-01-en-motherboard joyit-amd1250_1_gb_250gb_pcsJesus Villalobo
 
데이타맥스프린터 DATAMAX A-Class 열전사 RFID 바코드프린터엔진 오토라벨러엔진 매뉴얼
데이타맥스프린터 DATAMAX A-Class 열전사 RFID 바코드프린터엔진 오토라벨러엔진 매뉴얼데이타맥스프린터 DATAMAX A-Class 열전사 RFID 바코드프린터엔진 오토라벨러엔진 매뉴얼
데이타맥스프린터 DATAMAX A-Class 열전사 RFID 바코드프린터엔진 오토라벨러엔진 매뉴얼HION IT
 
Commander sx user guide
Commander sx user guideCommander sx user guide
Commander sx user guideToàn Huỳnh
 
I s7 eng_101201
I s7 eng_101201I s7 eng_101201
I s7 eng_101201Chan Suk
 
Pd0009 v1.0 installation process manual 22 jan-16 (low res)
Pd0009 v1.0 installation process manual 22 jan-16 (low res)Pd0009 v1.0 installation process manual 22 jan-16 (low res)
Pd0009 v1.0 installation process manual 22 jan-16 (low res)Berke Çevik
 
M700 70 navi mill-ib1500144-e
M700 70 navi mill-ib1500144-eM700 70 navi mill-ib1500144-e
M700 70 navi mill-ib1500144-eLong Nhu
 
Installation and operations_manual
Installation and operations_manualInstallation and operations_manual
Installation and operations_manualxmeteorite
 
Commander se users guide
Commander se users guideCommander se users guide
Commander se users guideToàn Huỳnh
 

Similar to Iscom2110 ea ma(rev.a) user manual 201104 (20)

manualdeservicioXeroxDC250FullServiceManual.pdf
manualdeservicioXeroxDC250FullServiceManual.pdfmanualdeservicioXeroxDC250FullServiceManual.pdf
manualdeservicioXeroxDC250FullServiceManual.pdf
 
TM.P7.02.pdf
TM.P7.02.pdfTM.P7.02.pdf
TM.P7.02.pdf
 
Panduan pelanggan fast net cable modem motorola sb5101
Panduan pelanggan fast net cable modem motorola sb5101Panduan pelanggan fast net cable modem motorola sb5101
Panduan pelanggan fast net cable modem motorola sb5101
 
Siemens micromaster-440-manual
Siemens micromaster-440-manualSiemens micromaster-440-manual
Siemens micromaster-440-manual
 
NB Designer Manual Operation [unlockplc.com]
NB Designer Manual Operation [unlockplc.com]NB Designer Manual Operation [unlockplc.com]
NB Designer Manual Operation [unlockplc.com]
 
Beetle / Express operating manual (english)
Beetle / Express operating manual (english)Beetle / Express operating manual (english)
Beetle / Express operating manual (english)
 
Msi k9 n_series_manual
Msi k9 n_series_manualMsi k9 n_series_manual
Msi k9 n_series_manual
 
SOLAR PUMP INVERTER MANUAL
SOLAR PUMP INVERTER MANUALSOLAR PUMP INVERTER MANUAL
SOLAR PUMP INVERTER MANUAL
 
872444 an-01-en-motherboard joyit-amd1250_1_gb_250gb_pcs
872444 an-01-en-motherboard joyit-amd1250_1_gb_250gb_pcs872444 an-01-en-motherboard joyit-amd1250_1_gb_250gb_pcs
872444 an-01-en-motherboard joyit-amd1250_1_gb_250gb_pcs
 
PLC: Manual del PLC micro3 IDEC
PLC: Manual del PLC micro3 IDECPLC: Manual del PLC micro3 IDEC
PLC: Manual del PLC micro3 IDEC
 
데이타맥스프린터 DATAMAX A-Class 열전사 RFID 바코드프린터엔진 오토라벨러엔진 매뉴얼
데이타맥스프린터 DATAMAX A-Class 열전사 RFID 바코드프린터엔진 오토라벨러엔진 매뉴얼데이타맥스프린터 DATAMAX A-Class 열전사 RFID 바코드프린터엔진 오토라벨러엔진 매뉴얼
데이타맥스프린터 DATAMAX A-Class 열전사 RFID 바코드프린터엔진 오토라벨러엔진 매뉴얼
 
GP2000E.pdf
GP2000E.pdfGP2000E.pdf
GP2000E.pdf
 
Commander sx user guide
Commander sx user guideCommander sx user guide
Commander sx user guide
 
I s7 eng_101201
I s7 eng_101201I s7 eng_101201
I s7 eng_101201
 
I s7 eng_101201
I s7 eng_101201I s7 eng_101201
I s7 eng_101201
 
P7 user manual
P7 user manualP7 user manual
P7 user manual
 
Pd0009 v1.0 installation process manual 22 jan-16 (low res)
Pd0009 v1.0 installation process manual 22 jan-16 (low res)Pd0009 v1.0 installation process manual 22 jan-16 (low res)
Pd0009 v1.0 installation process manual 22 jan-16 (low res)
 
M700 70 navi mill-ib1500144-e
M700 70 navi mill-ib1500144-eM700 70 navi mill-ib1500144-e
M700 70 navi mill-ib1500144-e
 
Installation and operations_manual
Installation and operations_manualInstallation and operations_manual
Installation and operations_manual
 
Commander se users guide
Commander se users guideCommander se users guide
Commander se users guide
 

Iscom2110 ea ma(rev.a) user manual 201104

  • 2. Legal Notices Raisecom Technology Co., Ltd makes no warranty of any kind with regard to this manual, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Raisecom Technology Co., Ltd shall not be held liable for errors contained herein or direct, indirect, special, incidental or consequential damages in connection with the furnishing, performance, or use of this material. Warranty. A copy of the specific warranty terms applicable to your Raisecom product and replacement parts can be obtained from Service Office. Restricted Rights Legend. All rights are reserved. No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Raisecom Technology Co., Ltd. The information contained in this document is subject to change without notice. Copyright Notices. Copyright ©2011 Raisecom. All rights reserved. No part of this publication may be excerpted, reproduced, translated or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in Writing from Raisecom Technology Co., Ltd. Trademark Notices is the trademark of Raisecom Technology Co., Ltd. Java™ is a U.S. trademark of Sun Microsystems, Inc. Microsoft® is a U.S. registered trademark of Microsoft Corporation. Windows NT® is a U.S. registered trademark of Microsoft Corporation. Windows® 2000 is a U.S. registered trademark of Microsoft Corporation. Windows® XP is a U.S. registered trademark of Microsoft Corporation. Windows® and MS Windows® are U.S. registered trademarks of Microsoft Corporation.
  • 3. Contact Information Technical Assistance Center The Raisecom TAC is available to all customers who need technical assistance with a Raisecom product, technology, or, solution. You can communicate with us through the following methods: Address: Building 2, No. 28 of the Shangdi 6th Street, Haidian District, Beijing 100085 Tel: +86-10-82883305 Fax: +86-10-82883056 World Wide Web You can access the most current Raisecom product information on the World Wide Web at the following URL: http://www.raisecom.com Feedback Comments and questions about how the ISCOM2110EA-MA (REV.A) device works are welcomed. Please review the FAQ in the related manual, and if your question is not covered, send email by using the following web page: http://www.raisecom.com/en/contact-us.html. If you have comments on the ISCOM2110EA-MA (REV.A) specification, instead of the web page above, please send comments to: export@raisecom.com We hope to hear from you!
  • 4. CONTENTS Chapter 1 Overview ------------------------------------------------------------------------------------ 1 1.1 Contents ---------------------------------------------------------------------------------------------------------------- 1 1.2 Terminology explanation --------------------------------------------------------------------------------------------- 1 Chapter 2 Technical Specifications --------------------------------------------------------------- 2 2.1 Hardware description------------------------------------------------------------------------------------------------- 2 2.2 Dimension of the device --------------------------------------------------------------------------------------------- 2 2.3 Working environment------------------------------------------------------------------------------------------------- 2 Chapter 3 Device Appearance And Description----------------------------------------------- 3 3.1 Front panel and explanation ---------------------------------------------------------------------------------------- 3 3.2 Rear panel and explanation ---------------------------------------------------------------------------------------- 3 Chapter 4 Installation And Connection ---------------------------------------------------------- 5 4.1 Device models --------------------------------------------------------------------------------------------------------- 5 4.2 Device installation ----------------------------------------------------------------------------------------------------- 5 4.2.1 Installation environment ----------------------------------------------------------------------------------------------------------- 5 4.2.2 Install onto the rack ---------------------------------------------------------------------------------------------------------------- 5 4.3 Connection of switch ------------------------------------------------------------------------------------------------- 5 4.3.1 Connect to CONSOLE------------------------------------------------------------------------------------------------------------- 5 4.3.2 Connect to Ethernet ---------------------------------------------------------------------------------------------------------------- 7 4.3.3 Connect to power supply---------------------------------------------------------------------------------------------------------- 7 4.4 Making cable ----------------------------------------------------------------------------------------------------------- 7 4.5 Power supply----------------------------------------------------------------------------------------------------------- 8 Chapter 5 Precautions -------------------------------------------------------------------------------- 9
  • 5. Preface About This Manual This manual is applicable to ISCOM2110EA-MA switch VER A.00 or higher version. Who Should Read This Manual This manual is a valuable reference for sales and marketing staff, after service staff and telecommunication network designers. For those who want to have an overview of the features, applications, structure and specifications of ISCOM2110EA-MA device, this is also a recommended document. Relevant Manuals ISCOM2110EA-MA Commands Notebook ISCOM2110EA-MA Configuration Guide Organization This manual is an introduction of the main functions of ISCOM2110EA-MA. To have a quick grasp of the using of ISCOM2110EA-MA, please read this manual carefully. The manual is composed of the following chapters: Chapter 1 Overview This chapter briefly introduces the content referred in this manual, reference documents and terminology explanations Chapter 2 Dimensions This chapter mainly introduces the hardware introduction and device dimensions. Chapter 3 Device Appearance And Description This chapter introduces the appearance of device and indicators description. Chapter 4 Installation and Connection This chapter introduces the device installation and connection. Chapter 5 Precautions
  • 6. General Safety Instructions The following instructions serve as a general guide for the safe installation and operation of telecommunications products. Additional instructions, if applicable, are included inside the manual. Safety Symbols This symbol may appear on the equipment or in the text. It indicates potential safety hazards regarding product operation or maintenance to operator or service personnel. Danger of electric shock! Avoid any contact with the marked surface while the product is energized or connected to outdoor telecommunication lines. Protective earth: the marked lug or terminal should be connected to the building protective earth bus. Some products have terminals which are permanently protective earthing conductors. Please be sure well connected to earthing before equipment connected to supply. Some products may be equipped with a laser diode. In such cases, a label with the laser class and other warnings as applicable will be attached near the optical transmitter. The laser warning symbol may be also attached. Please observe the following precautions: • Before turning on the chassis with optic module, make sure that the fiber optic cable is intact and is connected to the transmitter. • Do not attempt to adjust the laser drive current. • Do not use broken or unterminated fiber-optic cables/connectors or look straight at the laser beam. • The use of optical devices with the equipment will increase eye hazard. • Use of controls, adjustments or performing procedures other than those specified herein, may result in hazardous radiation exposure. ATTENTION: The laser beam may be invisible! Always observe standard safety precautions during installation, operation and maintenance of this product. Only qualified and authorized service personnel should carry out adjustment, maintenance or repairs to this product. No installation, adjustment, maintenance or repairs should be performed by either the operator or the user. Some products have more than one power supply cord. Disconnect 2 power supply cords before servicing to avoid electric shock. Before operating modules in the electricity conditions, please be noticed that optical modules shall be connected with optical fiber wires or shield with optical module cover for fear that laser light harms to operator’s eyes. It is suggested to apply optical module CLASS1 as laser. Handling Energized Products General Safety Practices Do not touch or tamper with the power supply when the power cord is connected. Line voltages may be present inside certain products even when the power switch (if installed) is in the OFF position or
  • 7. a fuse is blown. For DC-powered products, although the voltages levels are usually not hazardous, energy hazards may still exist. Before working on equipment connected to power lines or telecommunication lines, remove jewelry or any other metallic object that may come into contact with energized parts. Unless otherwise specified, all products are intended to be grounded during normal use. Grounding is provided by connecting the mains plug to a wall socket with a protective earth terminal. If an earth lug is provided on the product, it should be connected to the protective earth at all times, by a wire with a diameter of 18 AWG or wider. Rack-mounted equipment should be mounted only in earthed racks and cabinets. Always make the ground connection first and disconnect it last. Do not connect telecommunication cables to ungrounded equipment. Make sure that all other cables are disconnected before disconnecting the ground. Connection of AC Mains Make sure that the electrical installation complies with local codes. Always connect the AC plug to a wall socket with a protective ground. Always connect the power cord first to the equipment and then to the wall socket. If a power switch is provided in the equipment, set it to the OFF position. If the power cord cannot be readily disconnected in case of emergency, make sure that a readily accessible circuit breaker or emergency switch is installed in the building installation. Connection of DC Mains Unless otherwise specified in the manual, the DC input to the equipment is floating in reference to the ground. Any single pole can be externally grounded. Due to the high current capability of DC mains systems, care should be taken when connecting the DC supply to avoid short-circuits and fire hazards. DC units should be installed in a restricted access area, i.e. an area where access is authorized only to qualified service and maintenance personnel. Make sure that the DC supply is electrically isolated from any AC source and that the installation complies with the local codes. Before connecting the DC supply wires, ensure that power is removed from the DC circuit. Locate the circuit breaker of the panel board that services the equipment and switch it to the OFF position. When connecting the DC supply wires, first connect the ground wire to the corresponding terminal, then the positive pole and last the negative pole. Switch the circuit breaker back to the ON position. A readily accessible disconnect device that is suitably rated and approved should be incorporated in the building installation. Preventing Electrostatic Discharge Damage Modules which can be plugged into chassis are sensitive to damage from static electricity. Conversely, static voltages as high as 35,000V can be generated just by handling plastic or foam packing material, or by sliding assemblies across plastic and carpets. Not exercising the proper electrostatic discharge (ESD) precautions can result in intermittent or complete component failures. To minimize the potential for ESD damage, observe the following guidelines: • Always use an ESD-preventive antistatic wrist strap or ankle strap and ensure that it makes good skin contact. • When removing or installing a component, make sure the equipment end of your antistatic strap leash is connected to the ESD connection sockets on the front of the chassis or to a bare metal surface on the chassis. Avoid contact between the component and your clothing. The wrist strap only protects the component from ESD voltages on the body; ESD voltages on your clothing can still cause component damage. • Always place a card component-side-up on an antistatic surface, in an antistatic card rack, or in a static shielding bag. If you are returning the item to the factory, immediately place it in a static shielding bag. • Handle Modules by the metal card carrier edges only; Avoid touching the board or any connector pins.
  • 8. www.raisecom.com User Manual Chapter 1 Overview 1.1 Contents This manual describes how to install ISCOM2110EA-MA Switch, the features and component modules of the device and functions of every module. It provides a standard method of installation and cable specifications. This manual is for hardware installation and for additional configuration operations of software, refers to Configuration Guide. 1.2 Terminology explanation 10BASE-T Brief terminology of IEEE 802.3 f or LANs, operates at 10Mbps based on Manchester coding and uses category-3 or better twisted-pair cable. 100BASE-TX Brief terminology of IEEE 802.3 f or LANs, operates at 100Mbps based on 4B/5B coding and uses category-5 twisted-pair cable. 1000 Base-T Refer to normal standard of IEEE 802.3, providing PAM5X5 signal codes, 4 pairs of 100Ω CAT-5 UTP transmission, data transmitting speed up to 1Gbit/s Refer to normal standard of IEEE 802.3, Ethernet technology over optical 1000BASE-X fiber, generally refer to below concept in this document: 1000BaseSX Multi-mode Fiber 500 m 1000BaseLX Single-mode Fiber 3000 m Brief terminology of IEEE 802.3, fast Ethernet technology that uses optical 100BASE-FX fiber, single-mode and multi-mode fiber (62.5 and 125um available) connecting distance up to 550 meters. Auto-Negotiation detects the various modes that exist in the device on the Auto-negotiation other end of the wire, the Link Partner, and advertises its own abilities to automatically configure the highest performance mode of interoperation. Full-duplex Transmission of data in two directions simultaneously Data can be transmitted in both Rx and Tx directions on a signal carrier, but Half-duplex not at the same time. RJ-45 An eight-wire connector used in twister pair wire MDI Medium dependent interface, provides the physical and electrical connection to the cabling medium. MDIX MDI crossover, a version of MDI that enables connection between like devices. 1
  • 9. www.raisecom.com User Manual Chapter 2 Technical Specifications 2.1 Hardware description ISCOM2110EA-MA is professional layer-2 Ethernet switch to provide core or access switching for enterprises, residence community and school, etc. It provides 8 10/100Base-TX Ethernet electrical ports and 2 COMBO ports (100Base-FX and 1000Base-X compatible for SFP port, 10/100/1000Base-T for electrical port), the power of system is smaller than 10W, no fan inside. 2.2 Dimension of the device Dimension of ISCOM2110EA-MA is: 1U (H)* 260mm (W)* 130mm (D), weighted 1.17kg; it can be installed in 19-inch rack or put on the table. 2.3 Working environment  Environment temperature: 0° ~ 45°  Storage temperature: - 25° ~ 65°  Environment humidity: 10%~90% 2
  • 10. www.raisecom.com User Manual Chapter 3 Device Appearance And Description 3.1 Front panel and explanation The company logo and device model are located on the front panel of device, as figure shows below: 3.2 Rear panel and explanation On the rear panel of ISCOM2110EA-MA, there are 8 10/100M Ethernet electrical ports, 2 COMBO ports, status indicator LEDs and power supply interfaces. AC and DC power supply are of different interfaces, see in the following figures: 1 2 3 4 5 6 7 8 9 AC power supply DC power supply Description of the device panel: 1. 2 indicators for device status, SYS and PWR (marked as number 8 on the panel), definition of the LED: 3
  • 11. www.raisecom.com User Manual Indicator Color Status Indication ON System is initializing at the very beginning of power on device SYS Green Flickering System works normally OFF Software fault. ON System powered on PWR Green OFF System powered off 2. The 8 10/100M Ethernet electrical interfaces (marked as number 4 on panel) and related indicators (marked as nubmer 3), 1 indicator for each port, defined as LNK/ACT: Indicator Color Status Indication ON The interface is Link up LNK/ACT Green Flickering The interface is transmitting or receiving signal OFF The interface is Link down 3. The 2 C OMBO interfaces, including SFP optical port (marked as number 6) and electrical port (marked as number 7). 1 i ndicator (marked as number 5) for each COMBO interface, defined as LNK/ACT: Indicator Color Status Indication ON The interface is Link up LNK/ACT Green Flickering The interface is transmitting or receiving signal OFF The interface is Link down 4. The CONSOLE interface, locating on the right side of panel (marked as number 9). 5. Other interfaces: Number 1: place for safety grounding bolt; Number 2: interface for external power supply, 220V AC or -48V DC. 4
  • 12. www.raisecom.com User Manual Chapter 4 Installation And Connection 4.1 Device models The following device models are available now: Model Description Ethernet Layer-2 switch, 8 10/100M Ethernet electrical ports, ISCOM2110EA-MA-AC 2 COMBO ports (100/1000M SFP optical port and 10/100/1000M Ethernet electrical port) and 1 Console port, AC 220V power supply Ethernet Layer-2 switch, 8 10/100M Ethernet electrical ports, ISCOM2110EA-MA-DC 2 COMBO ports (100/1000M SFP optical port and 10/100/1000M Ethernet electrical port) and 1 Console port, DC -48V power supply Ethernet Layer-2 switch, 8 10/100M Ethernet electrical ports, ISCOM2110EA-MA-WP 2 COMBO ports (100/1000M SFP optical port and 10/100/1000M Ethernet electrical port) and 1 Console port, AC 220V or DC -48V power supply 4.2 Device installation 4.2.1 Installation environment There are heat exhausting inlets at back and on both sides of ISCOM2110EA-MA. To maintain ambient airflow there must be some space around the two sides or airflow path. The heat exhausting inlets should not be blocked in case that the airflow can not flow. 4.2.2 Install onto the rack Install the brackets onto the device and then fix the brackets on rack by the screws to make the device as stable as possible. 4.3 Connection of switch 4.3.1 Connect to CONSOLE ISCOM2110EA-MA provides RS-232C port in form of RJ45 as CONSOLE port. Connect the CONSOLE port to PC serial port by cable, then configure and control the device through the PC control platform.  Signal definition of CONSOLE port ISCOM2110EA-MA provides CONSOLE port in form of RJ45, the pin number of RJ45 plug and connector are showing as follows: 5
  • 13. www.raisecom.com User Manual Signaling and Pinouts of ISCOM2128EA-MA CONSOLE port: Pin number Signal Type 3 RxD In 6 TxD Out 4, 5 GND 1 ,2 ,7 ,8 N.C  Signaling and Pinouts of PC serial port: Pin No. Signal Type Pin No. Signal Type 1 DCD 6 DSR 2 RxD In 7 RTS 3 TxD Out 8 CTS 4 DTR 9 RI 5 GND  CONSOLE connection and parameters: PC serial interface I SCOM2110EA-MA CONSOLE Parameters of simulation program on PC terminal are as follows:  Baud rate – 9600 bps  Data bit– 8  Stop bit– 1  Parity– None  Flow control– None 6
  • 14. www.raisecom.com User Manual 4.3.2 Connect to Ethernet ISCOM2110EA-MA provides 8 10/100M auto-negotiation Ethernet electrical ports and 2 1000M COMBO uplink interfaces, it is available to configured as 1000M optical port, 100M optical port or 10/100/1000M electrical port. The Ethernet electrical ports of ISCOM2110EA-MA have auto-MDI/MDIX function when auto-negotiation enable. That is to say, the switch can perform MDI and MDIX signal switchover. The device can communication in order regardless to the peer device adopts MDI or MDIX port, straight-through or crossover network cable. Pin number of RJ45 plug and connector is available in signal definition of CONSOLE port.  Signaling and Pinouts of MDI and MDIX are in the following table: Pin No. MDI-X signal MDI signal 1 RD+ TD+ 2 RD- TD- 3 TD+ RD+ 6 TD- RD- 4 ,5 ,7 ,8 N.C N.C The Ethernet ports of ISCOM2110EA-MA are MDI-X ports when disable auto-negotiation, and can be connected to PC which has MDI port though straight-through cable. 4.3.3 Connect to power supply Take the power wire in attachment to connect power interface of ISCOM2110EA-MA with 220V (or -48V) power supply. NOTE: The switch is powered on once user connect power supply interface by power wire, therefore, please make sure the switch has been connected correctly before connecting power supply. 4.4 Making cable Pin number of RJ45 plug and connector is available in signal Definition of CONSOLE port.  Straight through cable (100M and 1000M straight through cable are identical) 7
  • 15. www.raisecom.com User Manual  100M crossover cable  1000M crossover cable 4.5 Power supply  After installing the device correctly following above steps, the device can be powered on by connecting the switch with 220V or -48V power supply.  PWR indicator ON means the system has been powered on.  All the indicator lights on front panel of ON means the system is self-checking and initializing.  After self-check and initialization, the device starts to operate, and then the SYS indicator starts flickering which means that system operates normally. Indicator LEDs of the 24 Ethernet ports indicate the status of ports (ON or OFF is according to port configuration and connection).  If the CONSOLE port is connected to PC and terminal software is configured correctly before system powered on, there will be user management interface on the PC screen, and then operation is available. (Specific operations are available in ISCOM2110EA-MA Configuration Guide). 8
  • 16. www.raisecom.com User Manual Chapter 5 Precautions Only trained and qualified personnel should install, maintain, or install the parts of ISCOM2110EA-MA. The device must be installed in a place where temperature and humidity can be controlled, meanwhile consider the electronic conductivity of surrounding materials. Extreme moisture may result in short circuit, and if too dry there may be fire. So there must be a suitable environment for the device.  The power supply must be grounded to discharge static.  There must be some space between device and the near electrical equipments.  We recommend that outside device routing intersect with live wire to avoid long paralleling.  Follow the guide strictly when installing.  Do not install the device when your hands are wet or with a lot of sweat.  Do not rebuild the device mechanically and electrically. 9
  • 17. Address: Building 2, No. 28 of the Shangdi 6th Street, Haidian District, Beijing Postcode: 100085 Tel: +86-10-82883305 Fax: +86-10-82883056 Email: export@raisecom.com http://www.raisecom.com