Project Profile
Coppice Primary School, Wythall

Consultant
■

Stuart Associates

Client
■

MVS Limited

Sector
Front Entrance

■ Education

Products
■ Wind-iVent Systems

Equipment
■ Natural Ventilation Systems
Wind-iVent - Natural Ventilation Systems

Application
■ Balance Terminals
Control Solutions Available

The Coppice Primary school is a two form entry school ,though larger than
the average primary school. Airtherm have already completed the 1 st phase
works by installing two ‘Wind-iVent’ Systems to the newly completed single
storey class rooms. The 2nd phase fix features a further six 1.2msq units for
the Hall area and a further six 1.1msq units serving the Classrooms
The new installation of two natural ventilation systems for MVS Limited
had been designed and carefully selected from the room data sheets
provided, ensuring adequate ventilation rates for the pupils are met.
The natural ventilation systems have been designed in line with all current
publications such as CIBSE guidelines, AM10 Natural Ventilation in
commercial buildings and Building Bulletin 101. The terminal sizes have
been selected by our new computer aided software ‘Wind-iCalc’ and fully
conforms to the CIBSE requirements.

0844 809 2509 | airtherm.co.uk | info@airtherm.co.uk
Product Solution
Product Range
The Airtherm “Wind-iVent” is a natural ventilation system operating on established
aerodynamic principles. As external wind flows around the terminal itself, positive
and negative pressure areas are generated. On the positive side air enters the louvres
of the terminal and is directed down through the internal vanes into the room below
allowing a fresh air supply to be delivered, and on the negative side the stack draws
the stale unwanted air which is expelled through the terminal into the atmosphere.

Manufacture

Natural Ventilation Terminals

The units are be manufactured in accordance with BS EN ISO 9001, and to suit the
architectural and design parameters as indicated in the design specification and
drawings. Internal airways are to be protected by incorporating anti-bird mesh to the
terminal louvers. Our systems can be manufactured to achieve 99.8% effectiveness
(class A) when tested with a simulate rainfall of 75mm/hour and wind speed of
15m/sec based on a free area of 55%.

Installation
Units can be installed on almost every roof including flat, pitched and even on the
roof apex where appropriate. The roof fabric of commercial applications has bearing
on the openings and roof plates that are required to install the systems competently.
We offer a roof plate solution for all situations, including self mount flashings and
curb mount flashings with suitable upstands.
The features and advantages of such a system:
☼ A fresh air supply for workers - proven to
External view on flat roof

increase productivity & reduce staff sickness
☼ Naturally ventilated - reduce your energy costs

Contact Details:

and carbon footprint without the need for

Airtherm Engineering Ltd

mechanical ventilation

Unit 8A,

☼ Night time purge of stale air - creating a fresh

Gainsborough Trading Est

working environment for staff the following

Stourbridge

morning

West Midlands
DY9 7ND

☼ Better control of building temperature and CO²
levels

Typical diagram

☼ Free cooling
Tel: 0844 8092509
Fax: 01384 375218

0844 809 2509 | airtherm.co.uk | info@airtherm.co.uk

Más contenido relacionado

Más de Airtherm Engineering

Natural Ventilation Installation - Case study for Bridge House, Tipton
Natural Ventilation Installation - Case study for Bridge House, TiptonNatural Ventilation Installation - Case study for Bridge House, Tipton
Natural Ventilation Installation - Case study for Bridge House, TiptonAirtherm Engineering
 
Flue Installation - Case study for marlow care home, marlow
Flue Installation - Case study for marlow care home, marlowFlue Installation - Case study for marlow care home, marlow
Flue Installation - Case study for marlow care home, marlowAirtherm Engineering
 
Case study for natural ventilation @ John Roan School
Case study for natural ventilation @ John Roan SchoolCase study for natural ventilation @ John Roan School
Case study for natural ventilation @ John Roan SchoolAirtherm Engineering
 
Natural Ventilation - Case study for coppice primary school
Natural Ventilation - Case study for coppice primary schoolNatural Ventilation - Case study for coppice primary school
Natural Ventilation - Case study for coppice primary schoolAirtherm Engineering
 
Airtherm case study coppice school, worcestershire
Airtherm case study   coppice school, worcestershireAirtherm case study   coppice school, worcestershire
Airtherm case study coppice school, worcestershireAirtherm Engineering
 
natural ventilation - Airtherm case study
natural ventilation - Airtherm case study   natural ventilation - Airtherm case study
natural ventilation - Airtherm case study Airtherm Engineering
 
Mini natural ventilation brochure 2013
Mini natural ventilation brochure 2013Mini natural ventilation brochure 2013
Mini natural ventilation brochure 2013Airtherm Engineering
 
Case study for lambeth hospital london
Case study for lambeth hospital    londonCase study for lambeth hospital    london
Case study for lambeth hospital londonAirtherm Engineering
 
Case study for coppice primary school
Case study for coppice primary schoolCase study for coppice primary school
Case study for coppice primary schoolAirtherm Engineering
 
Natural Ventilation - Case study for coppice primary school
Natural Ventilation - Case study for coppice primary schoolNatural Ventilation - Case study for coppice primary school
Natural Ventilation - Case study for coppice primary schoolAirtherm Engineering
 

Más de Airtherm Engineering (20)

Airtherm nat vent brochure
Airtherm nat vent brochureAirtherm nat vent brochure
Airtherm nat vent brochure
 
Natural Ventilation Installation - Case study for Bridge House, Tipton
Natural Ventilation Installation - Case study for Bridge House, TiptonNatural Ventilation Installation - Case study for Bridge House, Tipton
Natural Ventilation Installation - Case study for Bridge House, Tipton
 
Flue Installation - Case study for marlow care home, marlow
Flue Installation - Case study for marlow care home, marlowFlue Installation - Case study for marlow care home, marlow
Flue Installation - Case study for marlow care home, marlow
 
Case study for natural ventilation @ John Roan School
Case study for natural ventilation @ John Roan SchoolCase study for natural ventilation @ John Roan School
Case study for natural ventilation @ John Roan School
 
Chimney & Flue Systems MF Brocure
Chimney & Flue Systems MF BrocureChimney & Flue Systems MF Brocure
Chimney & Flue Systems MF Brocure
 
Natural Ventilation Brochure 2014
Natural Ventilation Brochure 2014Natural Ventilation Brochure 2014
Natural Ventilation Brochure 2014
 
Natural Ventilation - Case study for coppice primary school
Natural Ventilation - Case study for coppice primary schoolNatural Ventilation - Case study for coppice primary school
Natural Ventilation - Case study for coppice primary school
 
Airtherm case study coppice school, worcestershire
Airtherm case study   coppice school, worcestershireAirtherm case study   coppice school, worcestershire
Airtherm case study coppice school, worcestershire
 
natural ventilation - Airtherm case study
natural ventilation - Airtherm case study   natural ventilation - Airtherm case study
natural ventilation - Airtherm case study
 
Mini natural ventilation brochure 2013
Mini natural ventilation brochure 2013Mini natural ventilation brochure 2013
Mini natural ventilation brochure 2013
 
Case study for lambeth hospital london
Case study for lambeth hospital    londonCase study for lambeth hospital    london
Case study for lambeth hospital london
 
Case study for coppice primary school
Case study for coppice primary schoolCase study for coppice primary school
Case study for coppice primary school
 
Airtherm products
Airtherm productsAirtherm products
Airtherm products
 
Natural Ventilation - Case study for coppice primary school
Natural Ventilation - Case study for coppice primary schoolNatural Ventilation - Case study for coppice primary school
Natural Ventilation - Case study for coppice primary school
 
Natural Ventilation case study
Natural Ventilation case studyNatural Ventilation case study
Natural Ventilation case study
 
Generator Flues Brochure
Generator Flues BrochureGenerator Flues Brochure
Generator Flues Brochure
 
Airtherm flue portfolio
Airtherm flue portfolioAirtherm flue portfolio
Airtherm flue portfolio
 
Airtherm product range
Airtherm product rangeAirtherm product range
Airtherm product range
 
Airtherm grilles & louvre booklet
Airtherm grilles & louvre bookletAirtherm grilles & louvre booklet
Airtherm grilles & louvre booklet
 
flues and chimneys brochure 2013
flues and chimneys brochure 2013flues and chimneys brochure 2013
flues and chimneys brochure 2013
 

Natural Ventilation Systems - Case study for coppice primary school

  • 1. Project Profile Coppice Primary School, Wythall Consultant ■ Stuart Associates Client ■ MVS Limited Sector Front Entrance ■ Education Products ■ Wind-iVent Systems Equipment ■ Natural Ventilation Systems Wind-iVent - Natural Ventilation Systems Application ■ Balance Terminals Control Solutions Available The Coppice Primary school is a two form entry school ,though larger than the average primary school. Airtherm have already completed the 1 st phase works by installing two ‘Wind-iVent’ Systems to the newly completed single storey class rooms. The 2nd phase fix features a further six 1.2msq units for the Hall area and a further six 1.1msq units serving the Classrooms The new installation of two natural ventilation systems for MVS Limited had been designed and carefully selected from the room data sheets provided, ensuring adequate ventilation rates for the pupils are met. The natural ventilation systems have been designed in line with all current publications such as CIBSE guidelines, AM10 Natural Ventilation in commercial buildings and Building Bulletin 101. The terminal sizes have been selected by our new computer aided software ‘Wind-iCalc’ and fully conforms to the CIBSE requirements. 0844 809 2509 | airtherm.co.uk | info@airtherm.co.uk
  • 2. Product Solution Product Range The Airtherm “Wind-iVent” is a natural ventilation system operating on established aerodynamic principles. As external wind flows around the terminal itself, positive and negative pressure areas are generated. On the positive side air enters the louvres of the terminal and is directed down through the internal vanes into the room below allowing a fresh air supply to be delivered, and on the negative side the stack draws the stale unwanted air which is expelled through the terminal into the atmosphere. Manufacture Natural Ventilation Terminals The units are be manufactured in accordance with BS EN ISO 9001, and to suit the architectural and design parameters as indicated in the design specification and drawings. Internal airways are to be protected by incorporating anti-bird mesh to the terminal louvers. Our systems can be manufactured to achieve 99.8% effectiveness (class A) when tested with a simulate rainfall of 75mm/hour and wind speed of 15m/sec based on a free area of 55%. Installation Units can be installed on almost every roof including flat, pitched and even on the roof apex where appropriate. The roof fabric of commercial applications has bearing on the openings and roof plates that are required to install the systems competently. We offer a roof plate solution for all situations, including self mount flashings and curb mount flashings with suitable upstands. The features and advantages of such a system: ☼ A fresh air supply for workers - proven to External view on flat roof increase productivity & reduce staff sickness ☼ Naturally ventilated - reduce your energy costs Contact Details: and carbon footprint without the need for Airtherm Engineering Ltd mechanical ventilation Unit 8A, ☼ Night time purge of stale air - creating a fresh Gainsborough Trading Est working environment for staff the following Stourbridge morning West Midlands DY9 7ND ☼ Better control of building temperature and CO² levels Typical diagram ☼ Free cooling Tel: 0844 8092509 Fax: 01384 375218 0844 809 2509 | airtherm.co.uk | info@airtherm.co.uk