SlideShare una empresa de Scribd logo
1 de 17
OPERATING INSTRUCTIONS
                For the
                          PCI-600
Portable Primary Current Injection Device




                                                                                      Rev 1



   Agricultura 34 · 27003 Lugo [Spain] · T [+34] 982 20 99 20 · F [+34] 98220 99 11
                    info@amperis.com · www.amperis.com
PCI-600 Operating Instructions

                           SAFETY WARNINGS AND CAUTIONS
Only trained operators shall use this device. All circuits under test shall be off line and fully
isolated.

                                 Do Not Modify Test Equipment
Due to the risk of introducing additional or unknown hazards, do not install substitute parts or
perform any unauthorized modification to any PCI-600 test unit. To ensure that all designed
safety features are maintained, it is recommended that repairs be performed only by Amperis’
personnel or by an authorized repair service center. Unauthorized modifications can cause
serious safety hazards and will nullify the manufacturer's warranty.

                              Follow Exact Operating Procedures
Any deviation from the procedures described in the operator’s manual may create one or more
safety hazards, damage the PCI-600, or cause errors in the test results. Amperis Products S.L.
assumes no liability for unsafe or improper use of the PCI-600.




                                                1
PCI-600 Operating Instructions

                                                             Table of Contents

1.0 Introduction ............................................................................................................................ 6
        1.1 Furnished Test Accessories ........................................................................................ 6
2.0 PCI-600 Descriptions ............................................................................................................. 7
        2.1 PCI-600 Specifications ................................................................................................ 7
        2.2 PCI-600 Control and Display ...................................................................................... 8
3.0 Functional Description ......................................................................................................... 10
        3.1 PCI-600 AC Current Source ..................................................................................... 10
        3.2 PCI-600 Current Output Control ............................................................................... 10
        3.3 Timer Stop Input and Control .................................................................................... 11
        3.4 PCI-600 Timer ........................................................................................................... 11
        3.5 External Current Input ............................................................................................... 12
        3.5 LCD Contrast Control ................................................................................................ 12
4.0 Typical PCI-600 Applications ............................................................................................... 13
        4.1 Test the Time Delay of a Protection Relay ............................................................... 13
        4.2 Measure Current Transformer Primary and Secondary Currents ............................. 15




                                                                           2
PCI-600 Operating Instructions

                                                          List of Figures

Figure 1.0   PCI-600 Front Panel Controls and Display ................................................................. 8
Figure 2.0   PCI-600 Current Source and Timer Control ............................................................. 10
Figure 3.0   Timer Stop Input and Control ................................................................................... 11
Figure 4.0   External Current Input .............................................................................................. 12
Figure 5.0   PCI-600 Contrast Control ......................................................................................... 12
Figure 6.0   Typical PCI-600 Timing Application .......................................................................... 13
Figure 7.0   Typical PCI-600 Timing Test Result ......................................................................... 14
Figure 8.0   Typical Current Transformer Current Ratio Test ...................................................... 15
Figure 9.0   Typical PCI-600 CT Current Ratio Test Display ....................................................... 16




                                                                     4
PCI-600 Operating Instructions

                                                            List of Tables
Table 1.0 PCI-600 Specifications ................................................................................................ 7
Table 2.0 Functional Description of PCI-600 Controls and Display ............................................. 9
Table 3.0 Current Output vs Time ............................................................................................. 10




                                                                     5
PCI-600 Operating Instructions

1.0 Introduction
The Amperis Model PCI-600 is a portable, high-current source designed specifically for utility-
substation applications. This alternating current (AC) test device is used primarily for injection
testing of protective relays. The same device can also be used for testing thermal, magnetic
and solid-state motor-protection relays, and molded case circuit breakers. The PCI-600 is
versatile and can be used in many other applications that may require a high-current source.
The PCI-600 has the following features:
    One variable AC current source (0-600A).
    One internal current meter (range from 1 to 999 A).
    One built-in digital timer displays tested timing results in both milliseconds and cycles.
    An external current meter (input range from 0 to 10A) is also available to the user.
    Test results display on a 4-line by 20-character, back lighted LCD.

The front panel control arrangement is designed to allow a user to intuitively operate the PCI-
600 with a minimum of training.

1.1 Furnished Test Accessories
The PCI-600 is supplied with two 10-foot #1/0 AWG current cables with heavy-duty alligator
clamps, two 6-foot voltage-sensing cables with alligator clips, ground cable, and power cord.




                                                6
PCI-600 Operating Instructions

2.0 PCI-600 Descriptions
2.1 PCI-600 Specifications
PCI-600 specifications and leading particulars are listed in Table 1.0

                                  Table 1.0 PCI-600 Specifications

MODEL                                 PCI-600

TYPE                                  Special-Purpose Test Equipment, 10-600 amp current source

SIZE (inches)                         16.8 W by 12.6 H by 10.6 D (42.6 cm by 32.0 cm x 30.5 cm)

WEIGHT                                46 pounds (21 Kg)

INPUT POWER                           90-130 Vac or 200-240 Vac, 50/60 Hz (factory preset).

INTERNAL CURRENT METER                100 mA to 1000 A, Accuracy: 1% of reading, ±20 mA

EXTERNAL CURRENT METER                10 mA to 10 A, Accuracy: 1% of reading, ±20 mA

MEASURING METHOD                      Isolated CT

TIMER READING RANGE                   1 ms to 2 hours, Accuracy: 0.1% of reading ±1 ms

TIMER STOP INPUT                      Voltage Input (24-300 V, dc or peak AC)
                                      Or Dry contact input
                                      Or Interruption of primary current

DISPLAY                               LCD, backlighted, 4-line by 20-character

COMPUTER INTERFAC                     RS-23C, 19200 Baud (Factory Calibration and Diagnostic)

SAFETY                                Designed to meet IEC61010 (1995), UL 61010A-1, CSA-22.2

ENVIROMENT                            Operating: -10°C to 50°C (15°F to +122°F)
                                      Storage: -30°C to 70°C (-22°F to +158°F)




          PCI-600 SPECIFICATIONS ARE SUBJECT TO UPGRADES AND MAY BE CHANGED WITHOUT PRIOR NOTICE.


                                                     7
PCI-600 Operating Instructions

2.2 PCI-600 Control and Display
The PCI-600 controls and displays are shown in the control-panel illustration in Figure 1.0.
Pointing leader lines reference each item with an index number. Each index number is cross-
referenced to a functional description in Table 2.0, which describes the function and purpose of
each item on the control panel. Although the purpose of these controls and the display may
seem obvious and intuitive, users should become familiar with them before attempting to use
the PCI-600. First-time users should also review and become familiar with the Safety
Summary on the front page.




                    Figure 1.0 PCI-600 Front Panel Controls and Display




                                               8
PCI-600 Operating Instructions

           Table 2.0 Functional Description of PCI-600 Controls and Display
Figure 1      Adjacent Panel Marking                  Functional Description
Index #
1 & 14              (Wing Nut)          Current lead connectors

   2                No marking          LCD; 4-line by 20-character; back-lighted;
                                        displays menus of selections, operator entries,
                                        and test-measurement results.
   3              DRY CONTACT           Timer and current source stop input selection with
                  WET CONTACT           LED indicator. Stop input mode is selected by
                    CURRENT             using Arrow Key.


   4               TIMER STOP           Timer “STOP” input connectors

   5           EXTERNAL CURRENT         External current input connectors.

   6                90-120 Vac          Input power connector.
                  50- 60 Hz, 20A
                        or
                   200-240 Vac
                  50- 60 Hz, 10A

   7                No Marking          Circuit Breaker

   8                 GROUND             PCI-600 ground stud. Connect ground stud to
                    (Wing Nut)          substation ground using provided cable.

   9           CURRENT CONTROL          Current Control knob.

  10                 RS-232C            RS-232C interface port; 9-pin connector; female
                                        DB type. The data rate is set to 19,200 baud, 1
                                        start bit, 8 data bits, and no parity bit;
                                                      PIN              SIGNAL
                                                       2               Rx
                                                     3                  Tx
                                                     5                  Signal Gnd
                                        This serial port is for factory calibration and
                                        firmware updates.
  11         HIGH CURRENT PRESENT       High Current indicator LED
12 & 13         Up and Down Arrows      The up and down arrows allow the user to control
                                        the current source output and timer. Three modes
                    ON + TMR            are available:
                      OFF               ON+TIMR (Turn on current source and timer)
                     MONT               OFF (Turn off timer and current source)
                                        MONT (Turn on current source momentarily)


  15               CONTRAST             LCD contrast control.




                                          9
PCI-600 Operating Instructions

3.0 Functional Description
3.1 PCI-600 AC Current Source
     AC tests current, from 10A to 600A, are set by the “Current Control” knob on the front
panel. The test current is measured and displayed on the LCD. The PCI-600 output current
ratings are shown in table 3.0 below.

                              Table 3.0 Current Output vs Time
          Output @ 120 Vac        Output @ 240 Vac        Time

          5.6 Vac @ 100 A         9.5 Vac @ 100 A         1 hour

          5.3 Vac @ 200 A         9.4 Vac @ 200 A         5 minutes

          4.9 Vac @ 300 A         9.0 Vac @ 300 A         2 minutes

          4.6 Vac @ 400 A         8.2 Vac @ 400 A         1 minute

          4.2 Vac @ 500 A         7.5 Vac @ 500 A         30 seconds

          3.9 Vac @ 600 A         7.0 Vac @ 600 A         20 seconds


3.2 PCI-600 Current Output Control
The PCI-600 current source output is controlled by the “UP” and “DOWN” arrows shown in
Figure 2.0. Three control modes are available: “ON+TMR”, “OFF” and MONT”.
       The “OFF” mode indicates that both the current source output and timer are off.
       The “MONT” mode turns on the current source momentarily. To turn on the current
source, press and hold the “DOWN” arrow key. The “MONT” indicator indicates the PCI-600
current source is on and the output current is displayed on the LCD. The PCI-600 current
output can now be set by turning the “CURRENT CONTROL” knob. Release the “DOWN”
arrow key to turn off the current source.
       The “ON+TMR” mode turns on the PCI-600 current source and timer. This initiates a
test and is stopped by using the Timer Stop inputs. The test results will be displayed on the
LCD. The test can be terminated by pressing the “DOWN” arrow key. In this case, no test
results will be displayed on the LCD.




                   Figure 2.0 PCI-600 Current Source and Timer Control


                                               10
PCI-600 Operating Instructions

3.3 Timer Stop Input and Control
After a test is started, the PCI-600 timer can be stopped and the current source turned off
using one of three options: Dry contact input, Wet contact input, or when the PCI-600 current
output is interrupted. The user will use the “ARROW” key to select one of these 3 modes.
       DRY CONTACT Mode: When this mode is selected, the PCI-600 will output a DC
voltage to the “TIMER STOP” terminals to sense the state of dry contacts. A change in this dry
contact state will stop the timer and turn off the current source.
       WET CONTACT Mode: When this mode is selected, the PCI-600 will sense an AC or
DC voltage applied to the “TIMER STOP” connectors. The “OFF” state is a voltage from 0 to
10 V ac/dc. The “ON” state is a voltage from 24 to 300 V ac/dc.
A change in the “Voltage” state will stop the timer and turn of the current source.
       CURRENT Mode: When this mode is selected, an interruption of the PCI-600 current
source output (CB contact opened) will stop the timer and turn off the current source.

Both the “DRY CONTACT” and “WET CONTACT” modes require an external input to the PCI-
600. External timer stop input signals are sensed through the “TIMER STOP” connectors.




                          Figure 3.0 Timer Stop Input and Control


3.4 PCI-600 Timer
A built-in time/cycle counter allows the user to time events in milliseconds and cycles.
The elapsed time is displayed on the LCD along with the test current after a test is completed.
The timer is turned on when the “ON+TMR” mode is selected (see section 3.2)
.




                                               11
PCI-600 Operating Instructions

3.5 External Current Input
The PCI-600 “EXT CURRENT” is a 10 ampere AC current meter. This built-in ampere meter
allows the user to monitor an AC current. This current input is isolated. A typical application for
this feature is to measure a CT (Current Transformer) current ratio. The user can set the PCI-600
to output a current through the CT primary input. The CT secondary output is measured with the
PCI-600 “EXT CURRENT” input. Both the PCI-600 output current and the CT secondary current
are displayed on the LCD allowing the user to easily calculate the CT current ratio. The External
Current’s polarity with respect to the PCI-600 drive current is indicated on the LCD by a “+”
sign (in phase) or a “-“ sign (out of phase). Proper phasing is indicated when the same colored
PCI connectors are connected to corresponding terminals on the CT. For example: Red
Current connector to H1 / Red External Current connector to X1 and Black Current connector
to H2 / Black External Current connector to other “X” terminals.




                                Figure 4.0 External Current Input



3.5 LCD Contrast Control
To change the PCI-600 LCD contrast, press and hold the “Arrow” key shown in Figure 5.0. The
contrast will increase in darkness until it reaches its darkest setting at which point it will return
to its lightest setting and begin the cycle again. When the “Arrow” key is released, the LCD
contrast setting will be stored.




                              Figure 5.0 PCI-600 Contrast Control



                                                 12
PCI-600 Operating Instructions

4.0 Typical PCI-600 Applications
4.1 Test the Time Delay of a Protection Relay




                        Figure 6.0 Typical PCI-600 Timing Application

Figure 6.0 illustrates a typical connection of the PCI-600 to a protection relay to test its “Open
Time Delay”. The PCI-600 injects a test current through a bus. The test current is sensed by
the CT of the protection relay. One of the relay dry contacts is used to stop the PCI-600 timer.
Use the following steps to run this test.
       • Connect the Safety Ground to the PCI-600
       • Connect the Current cables from the PCI-600 to the bus.
       • Connect the Timer Stop cables.
       • Turn the Current control Knob to Zero.
       • Turn on the power switch.
       • Select the Timer Stop Input to “Dry Contact”.
       • Hold the “↓” key to momentarily turn on the current source.
       • Turn the “Current Control” Knob to set the desired current
       • Release the “↓” key
       • Press the “↑” key to (select ON+TIMER) to start the test
The PCI-600 will inject the preset current into the bus and turn on the timer. The timer will stop
and the current source turn off when the PCI-600 “TIMER STOP” detects a change in the relay
dry contact.
Typical PCI-600 time delay test results are shown in Figure 7.0.


                                                13
PCI-600 Operating Instructions



                                      986 mS     59.2CY

                                      Ext I: +0.000 A
                                      Drv I: 20.00A


                        Figure 7.0 Typical PCI-600 Timing Test Result

                                               Notes
In the above test, the timer and current source will stop with the change in the Timer Stop input or
when operator press the “DOWN ARROW” key to select the “OFF” mode.




                                                 14
PCI-600 Operating Instructions

4.2 Measure Current Transformer Primary and Secondary Currents
Figure 8.0 illustrates a typical connection of the PCI-600 to a current transformer. In this
connection, the PCI-600 injects a test current through the CT primary. The CT secondary
current is sensed by the PCI-600 “EXT CURRENT” input.




                 Figure 8.0 Typical Current Transformer Current Ratio Test

Use the following steps to run this test.
      • Connect the Safety Ground to the PCI-600
      • Connect the Current cables from the PCI-600 to the bus. (CT primary)
      • Connect the CT secondary winding to the PCI-600 “EXT CURRENT” input.
      • Turn the Current control Knob to Zero.
      • Turn on the power switch.
      • Hold the “↓” key to momentarily turn on the current source.
      • Turn the “Current Control” Knob to set the desired current
      • Release the “↓” key
      • Press the “↑” key (select ON+TIMER) to start the test
      • Observe and record the CT primary, CT secondary current, and polarity.
      • Turn off the current source using the “DOWN ARROW” key.




                                                15
PCI-600 Operating Instructions



                                       986 mS     59.2CY
                      Polarity
                                       Ext I: -1.004 A
                                       Drv I: 20.00A


                  Figure 9.0 Typical PCI-600 CT Current Ratio Test Display


                                              Notes
The External Current polarity is shown as in phase (“+” sign) or out of phase (“-“ sign) with
respect to the PCI-600 drive current.




                                                 16
PCI-600 Operating Instructions




www.amperis.com




       17

Más contenido relacionado

Similar a Manual Primary Current Injector PCI Amperis

iCLSeries Closed Stepper Motor Manual.pdf
iCLSeries Closed Stepper Motor Manual.pdfiCLSeries Closed Stepper Motor Manual.pdf
iCLSeries Closed Stepper Motor Manual.pdfSTEPPERONLINE
 
CW-15K_checkweigher User’s manual ( A p p l i c a b l e f o r M C G S + C 0 1...
CW-15K_checkweigher User’s manual ( A p p l i c a b l e f o r M C G S + C 0 1...CW-15K_checkweigher User’s manual ( A p p l i c a b l e f o r M C G S + C 0 1...
CW-15K_checkweigher User’s manual ( A p p l i c a b l e f o r M C G S + C 0 1...General Measure
 
GM ChexGo CW-30K Checkweigher user manual
GM ChexGo CW-30K Checkweigher user manualGM ChexGo CW-30K Checkweigher user manual
GM ChexGo CW-30K Checkweigher user manualGeneral Measure
 
cts320_manual.pdf
cts320_manual.pdfcts320_manual.pdf
cts320_manual.pdfTrung855324
 
Original PNP Transistor 2SA2098 SA2098 2098 TO-220 New Sanyo
Original PNP Transistor 2SA2098 SA2098 2098 TO-220 New SanyoOriginal PNP Transistor 2SA2098 SA2098 2098 TO-220 New Sanyo
Original PNP Transistor 2SA2098 SA2098 2098 TO-220 New SanyoAUTHELECTRONIC
 
F4 s instruction manual
F4 s instruction manualF4 s instruction manual
F4 s instruction manualToàn Huỳnh
 
CW-1.2K checkweigher.pdf
CW-1.2K checkweigher.pdfCW-1.2K checkweigher.pdf
CW-1.2K checkweigher.pdfGeneral Measure
 
Q46CT-Toroidal-Conductivity-Monitor-Manual.pdf
Q46CT-Toroidal-Conductivity-Monitor-Manual.pdfQ46CT-Toroidal-Conductivity-Monitor-Manual.pdf
Q46CT-Toroidal-Conductivity-Monitor-Manual.pdfENVIMART
 
Aruba 7000 Series Mobility Controller Data Sheet
Aruba 7000 Series Mobility Controller Data SheetAruba 7000 Series Mobility Controller Data Sheet
Aruba 7000 Series Mobility Controller Data Sheet美兰 曾
 
iRC3100N Service Manual - USER MANUAL.pdf
iRC3100N Service Manual - USER MANUAL.pdfiRC3100N Service Manual - USER MANUAL.pdf
iRC3100N Service Manual - USER MANUAL.pdfASHISHMAHAJAN99
 
Resize bientanfuji-dienhathe.com
Resize bientanfuji-dienhathe.comResize bientanfuji-dienhathe.com
Resize bientanfuji-dienhathe.comDien Ha The
 
EGmicro EG8010 Datasheet
EGmicro EG8010 DatasheetEGmicro EG8010 Datasheet
EGmicro EG8010 DatasheetChangyao Xu
 
3.81 inch OLED 1080X1200 MIPI
3.81 inch OLED 1080X1200 MIPI3.81 inch OLED 1080X1200 MIPI
3.81 inch OLED 1080X1200 MIPIPanox Display
 
Original Transistor PNP SS8550 S8550 8550 1.5A 40V TO-92 New
Original Transistor PNP SS8550 S8550 8550 1.5A 40V TO-92 NewOriginal Transistor PNP SS8550 S8550 8550 1.5A 40V TO-92 New
Original Transistor PNP SS8550 S8550 8550 1.5A 40V TO-92 NewAUTHELECTRONIC
 

Similar a Manual Primary Current Injector PCI Amperis (20)

iCLSeries Closed Stepper Motor Manual.pdf
iCLSeries Closed Stepper Motor Manual.pdfiCLSeries Closed Stepper Motor Manual.pdf
iCLSeries Closed Stepper Motor Manual.pdf
 
CW-15K_checkweigher User’s manual ( A p p l i c a b l e f o r M C G S + C 0 1...
CW-15K_checkweigher User’s manual ( A p p l i c a b l e f o r M C G S + C 0 1...CW-15K_checkweigher User’s manual ( A p p l i c a b l e f o r M C G S + C 0 1...
CW-15K_checkweigher User’s manual ( A p p l i c a b l e f o r M C G S + C 0 1...
 
Instrucsia chf100 a
Instrucsia chf100 aInstrucsia chf100 a
Instrucsia chf100 a
 
GM ChexGo CW-30K Checkweigher user manual
GM ChexGo CW-30K Checkweigher user manualGM ChexGo CW-30K Checkweigher user manual
GM ChexGo CW-30K Checkweigher user manual
 
Chv160 a manual
Chv160 a manualChv160 a manual
Chv160 a manual
 
cts320_manual.pdf
cts320_manual.pdfcts320_manual.pdf
cts320_manual.pdf
 
Original PNP Transistor 2SA2098 SA2098 2098 TO-220 New Sanyo
Original PNP Transistor 2SA2098 SA2098 2098 TO-220 New SanyoOriginal PNP Transistor 2SA2098 SA2098 2098 TO-220 New Sanyo
Original PNP Transistor 2SA2098 SA2098 2098 TO-220 New Sanyo
 
F4 s instruction manual
F4 s instruction manualF4 s instruction manual
F4 s instruction manual
 
CW-1.2K checkweigher.pdf
CW-1.2K checkweigher.pdfCW-1.2K checkweigher.pdf
CW-1.2K checkweigher.pdf
 
Q46CT-Toroidal-Conductivity-Monitor-Manual.pdf
Q46CT-Toroidal-Conductivity-Monitor-Manual.pdfQ46CT-Toroidal-Conductivity-Monitor-Manual.pdf
Q46CT-Toroidal-Conductivity-Monitor-Manual.pdf
 
Aruba 7000 Series Mobility Controller Data Sheet
Aruba 7000 Series Mobility Controller Data SheetAruba 7000 Series Mobility Controller Data Sheet
Aruba 7000 Series Mobility Controller Data Sheet
 
Q gx developer_e
Q gx developer_eQ gx developer_e
Q gx developer_e
 
iRC3100N Service Manual - USER MANUAL.pdf
iRC3100N Service Manual - USER MANUAL.pdfiRC3100N Service Manual - USER MANUAL.pdf
iRC3100N Service Manual - USER MANUAL.pdf
 
Resize bientanfuji-dienhathe.com
Resize bientanfuji-dienhathe.comResize bientanfuji-dienhathe.com
Resize bientanfuji-dienhathe.com
 
slua748[1]
slua748[1]slua748[1]
slua748[1]
 
EGmicro EG8010 Datasheet
EGmicro EG8010 DatasheetEGmicro EG8010 Datasheet
EGmicro EG8010 Datasheet
 
Bc327
Bc327Bc327
Bc327
 
semiconductor Bc327
semiconductor Bc327semiconductor Bc327
semiconductor Bc327
 
3.81 inch OLED 1080X1200 MIPI
3.81 inch OLED 1080X1200 MIPI3.81 inch OLED 1080X1200 MIPI
3.81 inch OLED 1080X1200 MIPI
 
Original Transistor PNP SS8550 S8550 8550 1.5A 40V TO-92 New
Original Transistor PNP SS8550 S8550 8550 1.5A 40V TO-92 NewOriginal Transistor PNP SS8550 S8550 8550 1.5A 40V TO-92 New
Original Transistor PNP SS8550 S8550 8550 1.5A 40V TO-92 New
 

Más de Amperis

Battery tester manual
Battery tester manualBattery tester manual
Battery tester manualAmperis
 
Partial discharge detector manual
Partial discharge detector manualPartial discharge detector manual
Partial discharge detector manualAmperis
 
Manual comprobador interruptores Amperis CT6500
Manual comprobador interruptores Amperis CT6500Manual comprobador interruptores Amperis CT6500
Manual comprobador interruptores Amperis CT6500Amperis
 
Prueba y verificación de relés Amperis RFD200
Prueba y verificación de relés Amperis RFD200Prueba y verificación de relés Amperis RFD200
Prueba y verificación de relés Amperis RFD200Amperis
 
Manual Ohmetro Drm10 A Es
Manual Ohmetro Drm10 A EsManual Ohmetro Drm10 A Es
Manual Ohmetro Drm10 A EsAmperis
 
Ohmimetro Amperis DRM-10a
Ohmimetro Amperis DRM-10aOhmimetro Amperis DRM-10a
Ohmimetro Amperis DRM-10aAmperis
 
Medidor de resistencia de aislamiento Amperis MIC-5000 - Manual de Operación
Medidor de resistencia de aislamiento Amperis MIC-5000 - Manual de OperaciónMedidor de resistencia de aislamiento Amperis MIC-5000 - Manual de Operación
Medidor de resistencia de aislamiento Amperis MIC-5000 - Manual de OperaciónAmperis
 

Más de Amperis (7)

Battery tester manual
Battery tester manualBattery tester manual
Battery tester manual
 
Partial discharge detector manual
Partial discharge detector manualPartial discharge detector manual
Partial discharge detector manual
 
Manual comprobador interruptores Amperis CT6500
Manual comprobador interruptores Amperis CT6500Manual comprobador interruptores Amperis CT6500
Manual comprobador interruptores Amperis CT6500
 
Prueba y verificación de relés Amperis RFD200
Prueba y verificación de relés Amperis RFD200Prueba y verificación de relés Amperis RFD200
Prueba y verificación de relés Amperis RFD200
 
Manual Ohmetro Drm10 A Es
Manual Ohmetro Drm10 A EsManual Ohmetro Drm10 A Es
Manual Ohmetro Drm10 A Es
 
Ohmimetro Amperis DRM-10a
Ohmimetro Amperis DRM-10aOhmimetro Amperis DRM-10a
Ohmimetro Amperis DRM-10a
 
Medidor de resistencia de aislamiento Amperis MIC-5000 - Manual de Operación
Medidor de resistencia de aislamiento Amperis MIC-5000 - Manual de OperaciónMedidor de resistencia de aislamiento Amperis MIC-5000 - Manual de Operación
Medidor de resistencia de aislamiento Amperis MIC-5000 - Manual de Operación
 

Último

Punjabi Housewife Call Girls Service Gomti Nagar \ 9548273370 Indian Call Gir...
Punjabi Housewife Call Girls Service Gomti Nagar \ 9548273370 Indian Call Gir...Punjabi Housewife Call Girls Service Gomti Nagar \ 9548273370 Indian Call Gir...
Punjabi Housewife Call Girls Service Gomti Nagar \ 9548273370 Indian Call Gir...nagunakhan
 
(AISHA) Ambegaon Khurd Call Girls Just Call 7001035870 [ Cash on Delivery ] P...
(AISHA) Ambegaon Khurd Call Girls Just Call 7001035870 [ Cash on Delivery ] P...(AISHA) Ambegaon Khurd Call Girls Just Call 7001035870 [ Cash on Delivery ] P...
(AISHA) Ambegaon Khurd Call Girls Just Call 7001035870 [ Cash on Delivery ] P...ranjana rawat
 
Petrosains Drama Competition (PSDC).pptx
Petrosains Drama Competition (PSDC).pptxPetrosains Drama Competition (PSDC).pptx
Petrosains Drama Competition (PSDC).pptxIgnatiusAbrahamBalin
 
Recommendable # 971589162217 # philippine Young Call Girls in Dubai By Marina...
Recommendable # 971589162217 # philippine Young Call Girls in Dubai By Marina...Recommendable # 971589162217 # philippine Young Call Girls in Dubai By Marina...
Recommendable # 971589162217 # philippine Young Call Girls in Dubai By Marina...home
 
WAEC Carpentry and Joinery Past Questions
WAEC Carpentry and Joinery Past QuestionsWAEC Carpentry and Joinery Past Questions
WAEC Carpentry and Joinery Past QuestionsCharles Obaleagbon
 
The_Canvas_of_Creative_Mastery_Newsletter_April_2024_Version.pdf
The_Canvas_of_Creative_Mastery_Newsletter_April_2024_Version.pdfThe_Canvas_of_Creative_Mastery_Newsletter_April_2024_Version.pdf
The_Canvas_of_Creative_Mastery_Newsletter_April_2024_Version.pdfAmirYakdi
 
Stark Industries Marketing Plan (1).pptx
Stark Industries Marketing Plan (1).pptxStark Industries Marketing Plan (1).pptx
Stark Industries Marketing Plan (1).pptxjeswinjees
 
Chapter 19_DDA_TOD Policy_First Draft 2012.pdf
Chapter 19_DDA_TOD Policy_First Draft 2012.pdfChapter 19_DDA_TOD Policy_First Draft 2012.pdf
Chapter 19_DDA_TOD Policy_First Draft 2012.pdfParomita Roy
 
Best VIP Call Girls Noida Sector 44 Call Me: 8448380779
Best VIP Call Girls Noida Sector 44 Call Me: 8448380779Best VIP Call Girls Noida Sector 44 Call Me: 8448380779
Best VIP Call Girls Noida Sector 44 Call Me: 8448380779Delhi Call girls
 
Captivating Charm: Exploring Marseille's Hillside Villas with Our 3D Architec...
Captivating Charm: Exploring Marseille's Hillside Villas with Our 3D Architec...Captivating Charm: Exploring Marseille's Hillside Villas with Our 3D Architec...
Captivating Charm: Exploring Marseille's Hillside Villas with Our 3D Architec...Yantram Animation Studio Corporation
 
Booking open Available Pune Call Girls Nanded City 6297143586 Call Hot India...
Booking open Available Pune Call Girls Nanded City  6297143586 Call Hot India...Booking open Available Pune Call Girls Nanded City  6297143586 Call Hot India...
Booking open Available Pune Call Girls Nanded City 6297143586 Call Hot India...Call Girls in Nagpur High Profile
 
SD_The MATATAG Curriculum Training Design.pptx
SD_The MATATAG Curriculum Training Design.pptxSD_The MATATAG Curriculum Training Design.pptx
SD_The MATATAG Curriculum Training Design.pptxjanettecruzeiro1
 
NO1 Trending kala jadu Love Marriage Black Magic Punjab Powerful Black Magic ...
NO1 Trending kala jadu Love Marriage Black Magic Punjab Powerful Black Magic ...NO1 Trending kala jadu Love Marriage Black Magic Punjab Powerful Black Magic ...
NO1 Trending kala jadu Love Marriage Black Magic Punjab Powerful Black Magic ...Amil baba
 
AMBER GRAIN EMBROIDERY | Growing folklore elements | Root-based materials, w...
AMBER GRAIN EMBROIDERY | Growing folklore elements |  Root-based materials, w...AMBER GRAIN EMBROIDERY | Growing folklore elements |  Root-based materials, w...
AMBER GRAIN EMBROIDERY | Growing folklore elements | Root-based materials, w...BarusRa
 
CBD Belapur Individual Call Girls In 08976425520 Panvel Only Genuine Call Girls
CBD Belapur Individual Call Girls In 08976425520 Panvel Only Genuine Call GirlsCBD Belapur Individual Call Girls In 08976425520 Panvel Only Genuine Call Girls
CBD Belapur Individual Call Girls In 08976425520 Panvel Only Genuine Call Girlsmodelanjalisharma4
 
Kala jadu for love marriage | Real amil baba | Famous amil baba | kala jadu n...
Kala jadu for love marriage | Real amil baba | Famous amil baba | kala jadu n...Kala jadu for love marriage | Real amil baba | Famous amil baba | kala jadu n...
Kala jadu for love marriage | Real amil baba | Famous amil baba | kala jadu n...babafaisel
 
Nepali Escort Girl Gomti Nagar \ 9548273370 Indian Call Girls Service Lucknow...
Nepali Escort Girl Gomti Nagar \ 9548273370 Indian Call Girls Service Lucknow...Nepali Escort Girl Gomti Nagar \ 9548273370 Indian Call Girls Service Lucknow...
Nepali Escort Girl Gomti Nagar \ 9548273370 Indian Call Girls Service Lucknow...nagunakhan
 
VIP Call Girl Amravati Aashi 8250192130 Independent Escort Service Amravati
VIP Call Girl Amravati Aashi 8250192130 Independent Escort Service AmravatiVIP Call Girl Amravati Aashi 8250192130 Independent Escort Service Amravati
VIP Call Girl Amravati Aashi 8250192130 Independent Escort Service AmravatiSuhani Kapoor
 
Escorts Service Basapura ☎ 7737669865☎ Book Your One night Stand (Bangalore)
Escorts Service Basapura ☎ 7737669865☎ Book Your One night Stand (Bangalore)Escorts Service Basapura ☎ 7737669865☎ Book Your One night Stand (Bangalore)
Escorts Service Basapura ☎ 7737669865☎ Book Your One night Stand (Bangalore)amitlee9823
 

Último (20)

Punjabi Housewife Call Girls Service Gomti Nagar \ 9548273370 Indian Call Gir...
Punjabi Housewife Call Girls Service Gomti Nagar \ 9548273370 Indian Call Gir...Punjabi Housewife Call Girls Service Gomti Nagar \ 9548273370 Indian Call Gir...
Punjabi Housewife Call Girls Service Gomti Nagar \ 9548273370 Indian Call Gir...
 
young call girls in Pandav nagar 🔝 9953056974 🔝 Delhi escort Service
young call girls in Pandav nagar 🔝 9953056974 🔝 Delhi escort Serviceyoung call girls in Pandav nagar 🔝 9953056974 🔝 Delhi escort Service
young call girls in Pandav nagar 🔝 9953056974 🔝 Delhi escort Service
 
(AISHA) Ambegaon Khurd Call Girls Just Call 7001035870 [ Cash on Delivery ] P...
(AISHA) Ambegaon Khurd Call Girls Just Call 7001035870 [ Cash on Delivery ] P...(AISHA) Ambegaon Khurd Call Girls Just Call 7001035870 [ Cash on Delivery ] P...
(AISHA) Ambegaon Khurd Call Girls Just Call 7001035870 [ Cash on Delivery ] P...
 
Petrosains Drama Competition (PSDC).pptx
Petrosains Drama Competition (PSDC).pptxPetrosains Drama Competition (PSDC).pptx
Petrosains Drama Competition (PSDC).pptx
 
Recommendable # 971589162217 # philippine Young Call Girls in Dubai By Marina...
Recommendable # 971589162217 # philippine Young Call Girls in Dubai By Marina...Recommendable # 971589162217 # philippine Young Call Girls in Dubai By Marina...
Recommendable # 971589162217 # philippine Young Call Girls in Dubai By Marina...
 
WAEC Carpentry and Joinery Past Questions
WAEC Carpentry and Joinery Past QuestionsWAEC Carpentry and Joinery Past Questions
WAEC Carpentry and Joinery Past Questions
 
The_Canvas_of_Creative_Mastery_Newsletter_April_2024_Version.pdf
The_Canvas_of_Creative_Mastery_Newsletter_April_2024_Version.pdfThe_Canvas_of_Creative_Mastery_Newsletter_April_2024_Version.pdf
The_Canvas_of_Creative_Mastery_Newsletter_April_2024_Version.pdf
 
Stark Industries Marketing Plan (1).pptx
Stark Industries Marketing Plan (1).pptxStark Industries Marketing Plan (1).pptx
Stark Industries Marketing Plan (1).pptx
 
Chapter 19_DDA_TOD Policy_First Draft 2012.pdf
Chapter 19_DDA_TOD Policy_First Draft 2012.pdfChapter 19_DDA_TOD Policy_First Draft 2012.pdf
Chapter 19_DDA_TOD Policy_First Draft 2012.pdf
 
Best VIP Call Girls Noida Sector 44 Call Me: 8448380779
Best VIP Call Girls Noida Sector 44 Call Me: 8448380779Best VIP Call Girls Noida Sector 44 Call Me: 8448380779
Best VIP Call Girls Noida Sector 44 Call Me: 8448380779
 
Captivating Charm: Exploring Marseille's Hillside Villas with Our 3D Architec...
Captivating Charm: Exploring Marseille's Hillside Villas with Our 3D Architec...Captivating Charm: Exploring Marseille's Hillside Villas with Our 3D Architec...
Captivating Charm: Exploring Marseille's Hillside Villas with Our 3D Architec...
 
Booking open Available Pune Call Girls Nanded City 6297143586 Call Hot India...
Booking open Available Pune Call Girls Nanded City  6297143586 Call Hot India...Booking open Available Pune Call Girls Nanded City  6297143586 Call Hot India...
Booking open Available Pune Call Girls Nanded City 6297143586 Call Hot India...
 
SD_The MATATAG Curriculum Training Design.pptx
SD_The MATATAG Curriculum Training Design.pptxSD_The MATATAG Curriculum Training Design.pptx
SD_The MATATAG Curriculum Training Design.pptx
 
NO1 Trending kala jadu Love Marriage Black Magic Punjab Powerful Black Magic ...
NO1 Trending kala jadu Love Marriage Black Magic Punjab Powerful Black Magic ...NO1 Trending kala jadu Love Marriage Black Magic Punjab Powerful Black Magic ...
NO1 Trending kala jadu Love Marriage Black Magic Punjab Powerful Black Magic ...
 
AMBER GRAIN EMBROIDERY | Growing folklore elements | Root-based materials, w...
AMBER GRAIN EMBROIDERY | Growing folklore elements |  Root-based materials, w...AMBER GRAIN EMBROIDERY | Growing folklore elements |  Root-based materials, w...
AMBER GRAIN EMBROIDERY | Growing folklore elements | Root-based materials, w...
 
CBD Belapur Individual Call Girls In 08976425520 Panvel Only Genuine Call Girls
CBD Belapur Individual Call Girls In 08976425520 Panvel Only Genuine Call GirlsCBD Belapur Individual Call Girls In 08976425520 Panvel Only Genuine Call Girls
CBD Belapur Individual Call Girls In 08976425520 Panvel Only Genuine Call Girls
 
Kala jadu for love marriage | Real amil baba | Famous amil baba | kala jadu n...
Kala jadu for love marriage | Real amil baba | Famous amil baba | kala jadu n...Kala jadu for love marriage | Real amil baba | Famous amil baba | kala jadu n...
Kala jadu for love marriage | Real amil baba | Famous amil baba | kala jadu n...
 
Nepali Escort Girl Gomti Nagar \ 9548273370 Indian Call Girls Service Lucknow...
Nepali Escort Girl Gomti Nagar \ 9548273370 Indian Call Girls Service Lucknow...Nepali Escort Girl Gomti Nagar \ 9548273370 Indian Call Girls Service Lucknow...
Nepali Escort Girl Gomti Nagar \ 9548273370 Indian Call Girls Service Lucknow...
 
VIP Call Girl Amravati Aashi 8250192130 Independent Escort Service Amravati
VIP Call Girl Amravati Aashi 8250192130 Independent Escort Service AmravatiVIP Call Girl Amravati Aashi 8250192130 Independent Escort Service Amravati
VIP Call Girl Amravati Aashi 8250192130 Independent Escort Service Amravati
 
Escorts Service Basapura ☎ 7737669865☎ Book Your One night Stand (Bangalore)
Escorts Service Basapura ☎ 7737669865☎ Book Your One night Stand (Bangalore)Escorts Service Basapura ☎ 7737669865☎ Book Your One night Stand (Bangalore)
Escorts Service Basapura ☎ 7737669865☎ Book Your One night Stand (Bangalore)
 

Manual Primary Current Injector PCI Amperis

  • 1. OPERATING INSTRUCTIONS For the PCI-600 Portable Primary Current Injection Device Rev 1 Agricultura 34 · 27003 Lugo [Spain] · T [+34] 982 20 99 20 · F [+34] 98220 99 11 info@amperis.com · www.amperis.com
  • 2. PCI-600 Operating Instructions SAFETY WARNINGS AND CAUTIONS Only trained operators shall use this device. All circuits under test shall be off line and fully isolated. Do Not Modify Test Equipment Due to the risk of introducing additional or unknown hazards, do not install substitute parts or perform any unauthorized modification to any PCI-600 test unit. To ensure that all designed safety features are maintained, it is recommended that repairs be performed only by Amperis’ personnel or by an authorized repair service center. Unauthorized modifications can cause serious safety hazards and will nullify the manufacturer's warranty. Follow Exact Operating Procedures Any deviation from the procedures described in the operator’s manual may create one or more safety hazards, damage the PCI-600, or cause errors in the test results. Amperis Products S.L. assumes no liability for unsafe or improper use of the PCI-600. 1
  • 3. PCI-600 Operating Instructions Table of Contents 1.0 Introduction ............................................................................................................................ 6 1.1 Furnished Test Accessories ........................................................................................ 6 2.0 PCI-600 Descriptions ............................................................................................................. 7 2.1 PCI-600 Specifications ................................................................................................ 7 2.2 PCI-600 Control and Display ...................................................................................... 8 3.0 Functional Description ......................................................................................................... 10 3.1 PCI-600 AC Current Source ..................................................................................... 10 3.2 PCI-600 Current Output Control ............................................................................... 10 3.3 Timer Stop Input and Control .................................................................................... 11 3.4 PCI-600 Timer ........................................................................................................... 11 3.5 External Current Input ............................................................................................... 12 3.5 LCD Contrast Control ................................................................................................ 12 4.0 Typical PCI-600 Applications ............................................................................................... 13 4.1 Test the Time Delay of a Protection Relay ............................................................... 13 4.2 Measure Current Transformer Primary and Secondary Currents ............................. 15 2
  • 4. PCI-600 Operating Instructions List of Figures Figure 1.0 PCI-600 Front Panel Controls and Display ................................................................. 8 Figure 2.0 PCI-600 Current Source and Timer Control ............................................................. 10 Figure 3.0 Timer Stop Input and Control ................................................................................... 11 Figure 4.0 External Current Input .............................................................................................. 12 Figure 5.0 PCI-600 Contrast Control ......................................................................................... 12 Figure 6.0 Typical PCI-600 Timing Application .......................................................................... 13 Figure 7.0 Typical PCI-600 Timing Test Result ......................................................................... 14 Figure 8.0 Typical Current Transformer Current Ratio Test ...................................................... 15 Figure 9.0 Typical PCI-600 CT Current Ratio Test Display ....................................................... 16 4
  • 5. PCI-600 Operating Instructions List of Tables Table 1.0 PCI-600 Specifications ................................................................................................ 7 Table 2.0 Functional Description of PCI-600 Controls and Display ............................................. 9 Table 3.0 Current Output vs Time ............................................................................................. 10 5
  • 6. PCI-600 Operating Instructions 1.0 Introduction The Amperis Model PCI-600 is a portable, high-current source designed specifically for utility- substation applications. This alternating current (AC) test device is used primarily for injection testing of protective relays. The same device can also be used for testing thermal, magnetic and solid-state motor-protection relays, and molded case circuit breakers. The PCI-600 is versatile and can be used in many other applications that may require a high-current source. The PCI-600 has the following features: One variable AC current source (0-600A). One internal current meter (range from 1 to 999 A). One built-in digital timer displays tested timing results in both milliseconds and cycles. An external current meter (input range from 0 to 10A) is also available to the user. Test results display on a 4-line by 20-character, back lighted LCD. The front panel control arrangement is designed to allow a user to intuitively operate the PCI- 600 with a minimum of training. 1.1 Furnished Test Accessories The PCI-600 is supplied with two 10-foot #1/0 AWG current cables with heavy-duty alligator clamps, two 6-foot voltage-sensing cables with alligator clips, ground cable, and power cord. 6
  • 7. PCI-600 Operating Instructions 2.0 PCI-600 Descriptions 2.1 PCI-600 Specifications PCI-600 specifications and leading particulars are listed in Table 1.0 Table 1.0 PCI-600 Specifications MODEL PCI-600 TYPE Special-Purpose Test Equipment, 10-600 amp current source SIZE (inches) 16.8 W by 12.6 H by 10.6 D (42.6 cm by 32.0 cm x 30.5 cm) WEIGHT 46 pounds (21 Kg) INPUT POWER 90-130 Vac or 200-240 Vac, 50/60 Hz (factory preset). INTERNAL CURRENT METER 100 mA to 1000 A, Accuracy: 1% of reading, ±20 mA EXTERNAL CURRENT METER 10 mA to 10 A, Accuracy: 1% of reading, ±20 mA MEASURING METHOD Isolated CT TIMER READING RANGE 1 ms to 2 hours, Accuracy: 0.1% of reading ±1 ms TIMER STOP INPUT Voltage Input (24-300 V, dc or peak AC) Or Dry contact input Or Interruption of primary current DISPLAY LCD, backlighted, 4-line by 20-character COMPUTER INTERFAC RS-23C, 19200 Baud (Factory Calibration and Diagnostic) SAFETY Designed to meet IEC61010 (1995), UL 61010A-1, CSA-22.2 ENVIROMENT Operating: -10°C to 50°C (15°F to +122°F) Storage: -30°C to 70°C (-22°F to +158°F) PCI-600 SPECIFICATIONS ARE SUBJECT TO UPGRADES AND MAY BE CHANGED WITHOUT PRIOR NOTICE. 7
  • 8. PCI-600 Operating Instructions 2.2 PCI-600 Control and Display The PCI-600 controls and displays are shown in the control-panel illustration in Figure 1.0. Pointing leader lines reference each item with an index number. Each index number is cross- referenced to a functional description in Table 2.0, which describes the function and purpose of each item on the control panel. Although the purpose of these controls and the display may seem obvious and intuitive, users should become familiar with them before attempting to use the PCI-600. First-time users should also review and become familiar with the Safety Summary on the front page. Figure 1.0 PCI-600 Front Panel Controls and Display 8
  • 9. PCI-600 Operating Instructions Table 2.0 Functional Description of PCI-600 Controls and Display Figure 1 Adjacent Panel Marking Functional Description Index # 1 & 14 (Wing Nut) Current lead connectors 2 No marking LCD; 4-line by 20-character; back-lighted; displays menus of selections, operator entries, and test-measurement results. 3 DRY CONTACT Timer and current source stop input selection with WET CONTACT LED indicator. Stop input mode is selected by CURRENT using Arrow Key. 4 TIMER STOP Timer “STOP” input connectors 5 EXTERNAL CURRENT External current input connectors. 6 90-120 Vac Input power connector. 50- 60 Hz, 20A or 200-240 Vac 50- 60 Hz, 10A 7 No Marking Circuit Breaker 8 GROUND PCI-600 ground stud. Connect ground stud to (Wing Nut) substation ground using provided cable. 9 CURRENT CONTROL Current Control knob. 10 RS-232C RS-232C interface port; 9-pin connector; female DB type. The data rate is set to 19,200 baud, 1 start bit, 8 data bits, and no parity bit; PIN SIGNAL 2 Rx 3 Tx 5 Signal Gnd This serial port is for factory calibration and firmware updates. 11 HIGH CURRENT PRESENT High Current indicator LED 12 & 13 Up and Down Arrows The up and down arrows allow the user to control the current source output and timer. Three modes ON + TMR are available: OFF ON+TIMR (Turn on current source and timer) MONT OFF (Turn off timer and current source) MONT (Turn on current source momentarily) 15 CONTRAST LCD contrast control. 9
  • 10. PCI-600 Operating Instructions 3.0 Functional Description 3.1 PCI-600 AC Current Source AC tests current, from 10A to 600A, are set by the “Current Control” knob on the front panel. The test current is measured and displayed on the LCD. The PCI-600 output current ratings are shown in table 3.0 below. Table 3.0 Current Output vs Time Output @ 120 Vac Output @ 240 Vac Time 5.6 Vac @ 100 A 9.5 Vac @ 100 A 1 hour 5.3 Vac @ 200 A 9.4 Vac @ 200 A 5 minutes 4.9 Vac @ 300 A 9.0 Vac @ 300 A 2 minutes 4.6 Vac @ 400 A 8.2 Vac @ 400 A 1 minute 4.2 Vac @ 500 A 7.5 Vac @ 500 A 30 seconds 3.9 Vac @ 600 A 7.0 Vac @ 600 A 20 seconds 3.2 PCI-600 Current Output Control The PCI-600 current source output is controlled by the “UP” and “DOWN” arrows shown in Figure 2.0. Three control modes are available: “ON+TMR”, “OFF” and MONT”. The “OFF” mode indicates that both the current source output and timer are off. The “MONT” mode turns on the current source momentarily. To turn on the current source, press and hold the “DOWN” arrow key. The “MONT” indicator indicates the PCI-600 current source is on and the output current is displayed on the LCD. The PCI-600 current output can now be set by turning the “CURRENT CONTROL” knob. Release the “DOWN” arrow key to turn off the current source. The “ON+TMR” mode turns on the PCI-600 current source and timer. This initiates a test and is stopped by using the Timer Stop inputs. The test results will be displayed on the LCD. The test can be terminated by pressing the “DOWN” arrow key. In this case, no test results will be displayed on the LCD. Figure 2.0 PCI-600 Current Source and Timer Control 10
  • 11. PCI-600 Operating Instructions 3.3 Timer Stop Input and Control After a test is started, the PCI-600 timer can be stopped and the current source turned off using one of three options: Dry contact input, Wet contact input, or when the PCI-600 current output is interrupted. The user will use the “ARROW” key to select one of these 3 modes. DRY CONTACT Mode: When this mode is selected, the PCI-600 will output a DC voltage to the “TIMER STOP” terminals to sense the state of dry contacts. A change in this dry contact state will stop the timer and turn off the current source. WET CONTACT Mode: When this mode is selected, the PCI-600 will sense an AC or DC voltage applied to the “TIMER STOP” connectors. The “OFF” state is a voltage from 0 to 10 V ac/dc. The “ON” state is a voltage from 24 to 300 V ac/dc. A change in the “Voltage” state will stop the timer and turn of the current source. CURRENT Mode: When this mode is selected, an interruption of the PCI-600 current source output (CB contact opened) will stop the timer and turn off the current source. Both the “DRY CONTACT” and “WET CONTACT” modes require an external input to the PCI- 600. External timer stop input signals are sensed through the “TIMER STOP” connectors. Figure 3.0 Timer Stop Input and Control 3.4 PCI-600 Timer A built-in time/cycle counter allows the user to time events in milliseconds and cycles. The elapsed time is displayed on the LCD along with the test current after a test is completed. The timer is turned on when the “ON+TMR” mode is selected (see section 3.2) . 11
  • 12. PCI-600 Operating Instructions 3.5 External Current Input The PCI-600 “EXT CURRENT” is a 10 ampere AC current meter. This built-in ampere meter allows the user to monitor an AC current. This current input is isolated. A typical application for this feature is to measure a CT (Current Transformer) current ratio. The user can set the PCI-600 to output a current through the CT primary input. The CT secondary output is measured with the PCI-600 “EXT CURRENT” input. Both the PCI-600 output current and the CT secondary current are displayed on the LCD allowing the user to easily calculate the CT current ratio. The External Current’s polarity with respect to the PCI-600 drive current is indicated on the LCD by a “+” sign (in phase) or a “-“ sign (out of phase). Proper phasing is indicated when the same colored PCI connectors are connected to corresponding terminals on the CT. For example: Red Current connector to H1 / Red External Current connector to X1 and Black Current connector to H2 / Black External Current connector to other “X” terminals. Figure 4.0 External Current Input 3.5 LCD Contrast Control To change the PCI-600 LCD contrast, press and hold the “Arrow” key shown in Figure 5.0. The contrast will increase in darkness until it reaches its darkest setting at which point it will return to its lightest setting and begin the cycle again. When the “Arrow” key is released, the LCD contrast setting will be stored. Figure 5.0 PCI-600 Contrast Control 12
  • 13. PCI-600 Operating Instructions 4.0 Typical PCI-600 Applications 4.1 Test the Time Delay of a Protection Relay Figure 6.0 Typical PCI-600 Timing Application Figure 6.0 illustrates a typical connection of the PCI-600 to a protection relay to test its “Open Time Delay”. The PCI-600 injects a test current through a bus. The test current is sensed by the CT of the protection relay. One of the relay dry contacts is used to stop the PCI-600 timer. Use the following steps to run this test. • Connect the Safety Ground to the PCI-600 • Connect the Current cables from the PCI-600 to the bus. • Connect the Timer Stop cables. • Turn the Current control Knob to Zero. • Turn on the power switch. • Select the Timer Stop Input to “Dry Contact”. • Hold the “↓” key to momentarily turn on the current source. • Turn the “Current Control” Knob to set the desired current • Release the “↓” key • Press the “↑” key to (select ON+TIMER) to start the test The PCI-600 will inject the preset current into the bus and turn on the timer. The timer will stop and the current source turn off when the PCI-600 “TIMER STOP” detects a change in the relay dry contact. Typical PCI-600 time delay test results are shown in Figure 7.0. 13
  • 14. PCI-600 Operating Instructions 986 mS 59.2CY Ext I: +0.000 A Drv I: 20.00A Figure 7.0 Typical PCI-600 Timing Test Result Notes In the above test, the timer and current source will stop with the change in the Timer Stop input or when operator press the “DOWN ARROW” key to select the “OFF” mode. 14
  • 15. PCI-600 Operating Instructions 4.2 Measure Current Transformer Primary and Secondary Currents Figure 8.0 illustrates a typical connection of the PCI-600 to a current transformer. In this connection, the PCI-600 injects a test current through the CT primary. The CT secondary current is sensed by the PCI-600 “EXT CURRENT” input. Figure 8.0 Typical Current Transformer Current Ratio Test Use the following steps to run this test. • Connect the Safety Ground to the PCI-600 • Connect the Current cables from the PCI-600 to the bus. (CT primary) • Connect the CT secondary winding to the PCI-600 “EXT CURRENT” input. • Turn the Current control Knob to Zero. • Turn on the power switch. • Hold the “↓” key to momentarily turn on the current source. • Turn the “Current Control” Knob to set the desired current • Release the “↓” key • Press the “↑” key (select ON+TIMER) to start the test • Observe and record the CT primary, CT secondary current, and polarity. • Turn off the current source using the “DOWN ARROW” key. 15
  • 16. PCI-600 Operating Instructions 986 mS 59.2CY Polarity Ext I: -1.004 A Drv I: 20.00A Figure 9.0 Typical PCI-600 CT Current Ratio Test Display Notes The External Current polarity is shown as in phase (“+” sign) or out of phase (“-“ sign) with respect to the PCI-600 drive current. 16