SlideShare una empresa de Scribd logo
1 de 34
Descargar para leer sin conexión
Common Europe Conference – Vienna | June 2012




VIOS in Action with IBM i

Janus Hertz
Senior IT Specialist
IBM EMEA ETS Center of Competency for Power Systems




Rev. 10-06-2012                                       © 2012 IBM Corporation
Common Europe Conference – Vienna | June 2012


What is the VIOS?

    A special purpose appliance partition
      – Provide I/O virtualization
      – Advanced Partition Virtualization enabler
    First GAed 2004
    Built on top of AIX, but not an AIX partition
    IBM i first attached to VIOS in 2008 with the IBM i 6.1
    VIOS is licensed with PowerVM




2                                                             © 2012 IBM Corporation
Common Europe Conference – Vienna | June 2012


Where Do I Start with Installing VIOS and IBM i on Power system?




        • Latest version at:
         http://www.ibm.com/systems/resources/systems_i_Virtualization_Open_Storage.pdf
3                                                                                © 2012 IBM Corporation
Common Europe Conference – Vienna | June 2012


                           I/O Virtualization on POWER

        IO Bus Virtualization                                IO Adapter Virtualization
       with Dedicated Adapters                                    with VIO Server

                                                                         VIOS LPAR
                LPAR A          LPAR B
                                                                                               LPAR A     LPAR B
              Physical       Physical
              Adapter        Adapter                          Physical
              DevDrv         DevDrv                           Adapter       Virtual Virtual   Virtual    Virtual
                                                Increasing                  Adapter Adapter   Adapter    Adapter
                                                              DevDrv        Server  Server    DevDrv     DevDrv
                                                Adapter BW
                                                 & LPAR
                      Hypervisor                 Density
                                                 per Slot                               Virtual Fabric
                                                                                         Hypervisor
               Func             Func
                            PCI adapter
            PCI adapter                                         Func

               Port             Port                          PCI adapter

                                                                Port

                       Fabric
                                                                  Fabric


4                                                                                                                  © 2012 IBM Corporation
Common Europe Conference – Vienna | June 2012


IBM i + VSCSI (Classic)
                                                   Source
             System 1
                                                 VIOS          IBM i Client    IBM i Client   IBM i Client
                                                                (System 1)      (System 2)     (System 3)


             System 2
                                                FC HBA

             System 3


                                                             6B22             6B22            6B22
                                                             Device           Device          Device
    •Assign storage to the physical HBA                      Type             Type            Type
    in the VIOS
    •Hostconnect is created as an open
    storage or AIX hosttype,
    •Requires 512 byte per sector LUNs
    to be assigned to the hostconnect
    •Cannot Migrate existing direct
    connect LUNs                                             Hypervisor
    •Many Storage options supported


                                                            POWER6 with IBM i 6.1.1


5                                                                                                      © 2012 IBM Corporation
Common Europe Conference – Vienna | June 2012


IBM i + VSCSI (Classic) Storage Virtualizer

                                                           VIOS                         IBM i Client
    •Storage is assigned to
    the VIOS partition
    •Within the VIOS you                          FC HBA
    map the hdisk (lun) to
    the vhost corresponding
    to the client partition
                                                                                        6B22
    •Storage management                                                                 Device
    allocation is done from                                                             Type
                                                vhostXXX          hdisk1
    both the external storage
                                                                  hdisk2
    box and the VIOS                            VSCSI                                    VSCSI
                                                SERVER                                   Client
    •Flexible disk sizes up to
    2Tb -512
    •16 disks per vscsi                                              Hypervisor
    adapter

                                                                   POWER6 with IBM i 6.1.1


6                                                                                                      © 2012 IBM Corporation
Common Europe Conference – Vienna | June 2012


IBM i + VSCSI Tape and optical

                                                           VIOS                         IBM i Client
    •Storage is assigned to
    the VIOS partition                                        CD1
                                                                                              OPT01
    •Within the VIOS you
    map physical tape or
    optical or file backed                                        RMT1
                                                                                                 TAP01
    virtual optical to the
    vhost corresponding to
                                                vhostXXX          cd1
    the client partition                                          rmt1

    •No tape library support
    with vscsi adpaters.                        VSCSI                                    VSCSI
    Must use VFC adapers.                       SERVER                                   Client




                                                                        Hypervisor



                                                                   POWER6 with IBM i 6.1.1


7                                                                                                        © 2012 IBM Corporation
Common Europe Conference – Vienna | June 2012


IBM i + NPIV ( Virtual Fiber Chanel )
                                                     Source
             System 1


                                                  VIOS             IBM i Client   IBM i Client    IBM i Client
                                                                    (System 1)     (System 1)      (System 1)
             System 2
                                                8Gbs HBA

             System 3




    •Hypervisor assigns 2 unique
    WWPNs to each Virtual fiber
                                                     Virtual address example C001234567890001
    •Hostconnect is created as an
    iSeries hosttype,                                            Hypervisor

    •Requires 520 byte per sector LUNs                        POWER6 with IBM i 6.1.1
    to be assigned to the iSeries
    hostconnect on DS8K
    •Can Migrate existing direct connect
    LUNS
    •DS8100, DS8300, DS8700,
                                                Note: an NPIV ( N_port ) capable switch is required to connect the
    DS8800, DS5100 and DS5300
                                                VIOS to the DS8000 to use virtual fiber.
    supported

8                                                                                                          © 2012 IBM Corporation
Common Europe Conference – Vienna | June 2012


NPIV Configuration - Limitations

            Single client adapter per physical port per partition
              –   Intended to avoid single point of failure
              –   Documentation only – not enforced


            Maximum of 64 active client connections per physical port
              –   It is possible to map more than 64 clients to a single adapter port
              –   May be less due to other VIOS resource constraints


            32K unique WWPN pairs per system platform
              –   Removing adapter does not reclaim WWPNs
                      Can be manually reclaimed through CLI (mksyscfg, chhwres )
                      “virtual_fc_adapters” attribute
              –   If exhausted, need to purchase activation code for more
            Device Limitations
              –   Maximum of 128 visible target ports
                     Not all visible target ports will necessarily be active
                     Redundant paths to a single DS8000 node
                     Device level port configuration
                     Inactive target ports still require client adapter resources
              –   Maximum of 64 target devices
                             Any combination of disk and tape
                             Tape libraries and tape drives are counted separately




9                                                                                       © 2012 IBM Corporation
Common Europe Conference – Vienna | June 2012


                                          Redundant VIOS with NPIV
                                 POWER6
                                                                        Step 1: configure virtual and physical FC adapters
                                                                          –    Best Practice to make VIOS redundant or
                                                                               separate individual VIOS partitions where a
                                   IBM i                                       single hardware failure would not take down
       Client            IASP                   SYSBAS                         both VIOS partitions.
        VFC
      adapters
                                                          Server
                                                           VFC          Step 2: configure SAN fabric and storage
                                                         adapters         –    Zone Luns to the virtual WWPNs.
                                                                          –    Each DASD sees a path through 2 VIOS
                                                                               partitions
                                    1
       VIOS                                              VIOS

                                                                    •Notes: Support up to 8 paths per LUN
                                                                          •Not all paths have to go through
                                                                          separate VIOS partitions.
                                                                          •New multi-path algorithm in 7.1 TR2
                                     2
     Physical FC
     connections



10                                                                                                       © 2012 IBM Corporation
Common Europe Conference – Vienna | June 2012




6B25 Adapter Look & Feel


       Similar in look & feel to
       other IOPless storage
       adapters




       Attached device resources
       have real hardware CCINs




11                                              © 2012 IBM Corporation
Common Europe Conference – Vienna | June 2012

                                        Support for IBM Storage Systems with IBM i

                                          DS3200
                                                        DS4700
    Table as of        N Series           DS3400                     Storwize       DS5100                                                      DS8100           DS8700
                                                        DS4800                                       DS6800          SVC           XIV
   April 5, 2011           @@             DS3500                      V7000         DS5300                                                      DS8300           DS8800
                                                        DS5020
                                          DS3950
                                          6.1 / 7.1                                                   5.4 / 6.1
             IBM i                       POWER6/7                                                   POWER5/6/7
                      5.4 / 6.1 / 7.1                    6.1 / 7.1    6.1 / 7.1      6.1 / 7.1                      6.1 / 7.1    6.1 / 7.1    5.4 / 6.1 / 7.1   5.4 / 6.1 / 7.1
            Version
 Rack /               POWER5/6/7                        POWER6/7     POWER6/7       POWER6/7                       POWER6/7     POWER6/7      POWER5/6/7        POWER5/6/7
           Hardware                      Not DS3200#,                                                Not 7.1 ###
 Tower                                   Yes DS3500##                                               POWER5/6/7
Systems
                                                                                  Direct* or VIOS                                            Direct or VIOS – Direct or VIOS –
            IBM i       IFS / NFS
                                            VIOS          VIOS         VIOS        –VSCSI and          Direct        VIOS         VIOS          VSCSI and        VSCSI and
            Attach        (NAS)                                                       NPIV%                                                       NPIV**           NPIV**


                         6.1 / 7.1        6.1 / 7.1
             IBM i                                       6.1 / 7.1    6.1 / 7.1      6.1 / 7.1                      6.1 / 7.1    6.1 / 7.1      6.1 / 7.1         6.1 / 7.1
                       POWER6/7         POWER6/7 @,                                                     Not
            Version                                     POWER6/7     POWER6/7       POWER6/7                       POWER6/7     POWER6/7       POWER6/7          POWER6/7
                        IFS / NFS           #, ##                                                    supported
Power      Hardware                                       (BCH)        (BCH)          (BCH)                          (BCH)        (BCH)          (BCH)             (BCH)
Blades                    (NAS)

            IBM i          IFS                                                                                                                   VIOS              VIOS
                                            VIOS          VIOS         VIOS           VIOS              n/a          VIOS         VIOS
            Attach        (NAS)                                                                                                                  NPIV**            NPIV**

  Notes
  - This table does not list more detailed considerations, for example required levels of firmware or PTFs required or configuration performance considerations
  - POWER7 servers require IBM i 6.1 or later
  - This table can change over time as addition hardware/software capabilities/options are added
  # DS3200 only supports SAS connection, not supported on Rack/Tower servers which use only Fibre Channel connections, supported on Blades with SAS
  ## DS3500 has either SAS or Fibre Channel connection. Ractk/Tower only uses Fibre Channel. Blades support either SAS or Fibre Channel (either BCS or BCH)
  ### Not supported on IBM i 7.1. But see SCORE System RPQ 846-15284 for exception support
  * Supported with Smart Fibre Channel adapters – NOT supported with IOP-based Fibre Channel adapters
  ** NPIV requires Machine Code Level of 6.1.1 or later and requires NPIV capable HBAs (FC adapters) and switches
  @ BCH supports DS3400, DS3500, DS3950 & BCS supports DS3200, DS3500
  @@ N Series can only be used as file server. No load source/boot support. Support only through IFS. No IBM i data base support
  % NPIV support for DS5100/DS5300 requires IBM i 7.1 TR2 and must have POWER7 firmware: Ax730_xxx or the POWER6 firmware Service Pack that will be
  released 2Q2011

 For more details, use the System Storage Interoperability Center:                           www.ibm.com/systems/support/storage/config/ssic/
 Note there are currently some differences between the above table and the SSIC. The SSIC should be updated to reflect the above information
12                                                                                                                                 © 2012 IBM Corporation
Common Europe Conference – Vienna | June 2012


IBM PowerVM Virtual Ethernet

                                                 Virtual I/O Server          Client 1            Client 2

                                                              Shared
     PowerVM Ethernet switch                                  Ethernet
                                                              Adapter
      – Part of PowerVM Hypervisor
                                                       ent       ent               CMN                  CMN
      – Moves data between LPARs                      (Phy)     (Vir)              (Vir)                (Vir)




     Shared Ethernet Adapter                                               VLAN-Aware Ethernet Switch
                                                                         PowerVM Hypervisor
      – Part of the VIO server
      – Logical device
                                                   Ethernet
      – Bridges traffic to and from                 Switch
         external networks

     Additional capabilities
      – VLAN aware
      – Link aggregation for external networks
      – SEA Failover for redundancy


13                                                                                               © 2012 IBM Corporation
Common Europe Conference – Vienna | June 2012




SEA Failover Configuration


                 VIOS                      VIOS                Partition     Partition
                 SEA




                                           SEA
                       VETH


                              VETH




                                                 VETH




                                                                      VETH




                                                                                VETH


                                                                                       VETH
                                                        VETH
           ETH




                                     ETH




                                             Hypervisor




                              Client
                              Network
                              network



14                                                                                            © 2012 IBM Corporation
Common Europe Conference – Vienna | June 2012


Virtual Ethernet Limits
Description                                                                          Limit




Maximum virtual Ethernet adapters per LPAR                                           256




Maximum number of VLANs per virtual adapter                                          21 VLAN (20 VID, 1 PVID)




Number of virtual adapter per single SEA sharing a single physical network adapter   16




Maximum number of VLAN IDs                                                           4094




Maximum number of physical adapters in a link aggregation                            8 primary, 1 backup




15                                                                                                              © 2012 IBM Corporation
Common Europe Conference – Vienna | June 2012

PowerVM Active Memory Sharing

         Reduce memory costs by improving memory utilization on Power Servers


      Supports over-commitment of logical memory with
      overflow going to a paging device                                                                            POWER Server

      Intelligently flow memory from one partition to                                                                                     Virtual
      another for increased utilization and flexibility                                                                                     I/O
                                                                                          Dedicated                                       Server
                                                                                           Memory
                                                                                                                Shared Memory
      Memory from a shared physical memory pool is
      dynamically allocated among logical partitions as
      needed to optimize overall memory usage
                                                                                              CPU                  Shared CPU
      Designed for partitions with variable memory
      requirements                                                                                                                        Paging



      PowerVM Enterprise Edition on POWER6 and                                                              PowerVM Hypervisor              AMS
      Power7 processor-based systems
        – Partitions must use VIOS for I/O
          virtualization
      Make sure it’s a good fit for you!


 16                                              * All statements regarding IBM's future direction and intent are subject to change or   © 2012 IBM Corporation
                                                 withdrawal without notice, and represent goals and objectives only.
Common Europe Conference – Vienna | June 2012


LPAR Suspend/Resume – Customer Value

       Resource balancing for long-running batch jobs
          – e.g. suspend lower priority and/or long running workloads to free resources.

       Planned CEC outages for maintenance/upgrades
          – Suspend/resume may be used in place of or in conjunction with partition mobility.
          – Suspend/resume may require less time and effort than manual database shutdown and restart,
            for example.




     Requirements:
     • All I/O is virtualized
     • HMC version 7 releases 7.3
     • FW: Ax730_xxx
     • IBM i 7.1 TR2
     • VIOS 2.2.1.0 FP24 SP2


17                                                                                          © 2012 IBM Corporation
Common Europe Conference – Vienna | June 2012


Partition Suspend/Resume                                      Partition Suspend/Resume supported on POWER7
                                                                                IBM i 7.1 TR2

          Power7 System #1
                                                                                           Storage
                     Suspended Partition
                        IBM i Client 1                                                    Subsystem
                                                      Validate environment
                                                         for appropriate
                                                            resources

                          A
                                  en0                  Ask partiton if it’s
                                  (if)
                                                       ready for suspend
                        vscsi0    ent1
                                                       Suspend Partition           ReservedStorage Pool
                                                         CPU and I/O                       LUN

               M M M M M M                            Move Memory and CPU
                                     VLAN                to Storage Pool
               C C C


                                         Hypervisor
                                                      Partition Suspended
              VASI      vhost0    ent1
                                                                                                           A
             Mover                ent2       en2
             Service    vtscsi0
                                  SEA        (if)


                         fcs0     ent0        VIOS




18                                                                                                    © 2012 IBM Corporation
Common Europe Conference – Vienna | June 2012


 PowerVM Live Partition Mobility


• Move running partition from one system to                          Live Partition Mobility
  another with almost no impact to end users

• Requires POWER7 systems or later, PowerVM
  Enterprise, and all I/O must be through the                                      Movement of the
                                                                                         OS and
  Virtual I/O Server                                                               applications to a
                                                                                    different server
                                                                                    with no loss of
                                                                                         service

• Requires IBM i 7.1 with TR4

                                                                     Virtualized storage and Network Infrastructure




                                                Potential Benefits
                            • Eliminate planned outages
                            • Balance workloads across systems
                            • Energy Savings

19                                                                                                 © 2012 IBM Corporation
Common Europe Conference – Vienna | June 2012


Requirements & Planning
        Source and destination must be mobility capable and
        compatible.
          – Enhanced hardware virtualization capabilities.
          – Identical or compatible processors.                               HMC
          – Compatible firmware levels.

        Source and destination must be LAN connected – same
        subnet.                                                                LAN
        All resources (CPU, Memory, IO adapters) must be           LPAR
        virtualized prior to migration.
          – Hypervisor will handle CPU and Memory
            automatically, as required. Virtual IO adapters                    SAN
            are pre-configured, and SAN-attached disks
            accessed through Virtual IO Server (VIOS)
                                                                                Boot
        Source and destination VIOS must have symmetrical access              Paging
        to the partition’s disks.                                         Application Data
          –     e.g. no internal or VIOS LVM-based disks.

        OS is migration enabled/aware.
          – Certain tools/middleware can benefit from being
            migration aware also.


20                                                                                      © 2012 IBM Corporation
Common Europe Conference – Vienna | June 2012


Live Partition Mobility                                                Partition Mobility supported on POWER7
                                                                                      IBM i 7.1 TR

          Power7 System #1                                                                                Power7 System #2

                       Suspended Partition
                          IBM i Client 1                                                         Shelli Partition
                                                                                                 IBM Client 1
                                                        Once enough memory
                                                         Finish the migration
                     M M M M M M M                      Validate environment               M M M M M M M
                                                        Create removebeen
                                                         Createshell partition
                                                          pages virtual SCSI
                                                            Start have the
                                                           and migrating
                                                            for appropriate
                                                         moved, suspend the
                                                           on target system
                                                            memory pages
                                                             original LPAR
                                                                devices
                                                               resources
                                    en0                     source system
                                                              definitions                       en0
                            A       (if)                                                        (if)        A

                          vscsi0    ent1                                                    ent1         vscsi0
                                                                 HMC
                                       VLAN                                           VLAN
                                           Hypervisor                              Hypervisor


              VASI        vhost0    ent1                                                    ent1         vhost0      VASI


             Mover                  ent2       en2                                  en2     ent2                    Mover
             Service     vtscsi0                                                                         vtscsi0    Service
                                    SEA        (if)                                 (if)    SEA


                           fcs0     ent0        VIOS                              VIOS
                                                                                            ent0          fcs0




                                                                Storage
                                                               Subsystem


                                                                  A


21                                                                                                                      © 2012 IBM Corporation
Common Europe Conference – Vienna | June 2012


Installing VIOS



     PowerVM Standard or Enterprise Edition must be ordered
      – VIOS install media
             migration utility
             install image
      – activation code
     Partition Creation
      – physical adapters
      – virtual adapters
     Partition Activation to SMS
     DVD Install
      – Can also install over network – NIM Server
     Post-Install Tasks




22                                                            © 2012 IBM Corporation
Common Europe Conference – Vienna | June 2012


Check VIOS enablement




 In HMC, display managed system’s properties
23                                              © 2012 IBM Corporation
Common Europe Conference – Vienna | June 2012


VIOS enablement




     Select managed system     Capacity on demand   Advanced POWER
     virtualization (now PowerVM)

     Enter 32-digit enablement code




24                                                              © 2012 IBM Corporation
Common Europe Conference – Vienna | June 2012


LPAR configuration – create a partition




25                                              © 2012 IBM Corporation
Common Europe Conference – Vienna | June 2012



VIOS partition configuration – physical IO




26                                              © 2012 IBM Corporation
Common Europe Conference – Vienna | June 2012


VIOS install: SMS setup




 When the partition is powered on, the PFW screen will appear
 Hit 1 to enter the SMS menu and set up the install source for
VIOS
27                                                     © 2012 IBM Corporation
Common Europe Conference – Vienna | June 2012


VIOS install: Select Install/Boot Device




  Select option 5, then option 1
28                                              © 2012 IBM Corporation
Common Europe Conference – Vienna | June 2012


VIOS install: Select DVD as boot device




29                                              © 2012 IBM Corporation
Common Europe Conference – Vienna | June 2012




VIOS install: verify disk unit




Choose option 2 to verify VIOS is going to be installed on the correct disk unit
30                                                                           © 2012 IBM Corporation
Common Europe Conference – Vienna | June 2012


VIOS install: verify disk unit




  hdisk0 is the first physical disk or LUN detected
 VIOS can be installed on mirrored integrated disk, or installed on the SAN
31                                                                            © 2012 IBM Corporation
Power Virtualization   IBM i and BladeCenter S
Common Europe Conference – Vienna | June 2012


System & Metode, Denmark
  www.system-method.com

  • IBM Business Partner
  • Software Solutions & Hosting company
         Focuses on very small / old existing installations
  • 1 BladeCenter S chassis
  • 1 JS12 POWER6 blade
  • 2 HS21 x86 blades

  • Provides hosting services to several clients/companies
  • 1 IBM Virtual IO Server 2.2 (VIOS) host LPAR
  • 9 IBM i 6.1 client LPARs – for different customers

  Pros:
  • Cheap hardware compared to traditional Power servers
  • Possible to get customers that would potentially have switched to the “dark side ”
  • Flexible
  Cons:
  • More complex, requires three different skills sets (Blade, VIOS, IBM i)
32                                                                                   © 2012 IBM Corporation
Common Europe Conference – Vienna | June 2012




References:
•    PowerVM Quicksheet - http://tablespace.net/quicksheet/powervm-quicksheet.pdf

•    PowerVM Quickstart - http://tablespace.net/quicksheet/powervm-quickstart.html

•    VIOS Cheat Sheet - http://www.ibm.com/developerworks/aix/library/au-
     viocheatsheet/index.html?ca=drs-

•    Get to know the VIOS CLI - http://www.ibm.com/developerworks/aix/library/au-
     vioscli/index.html?cmp=dw&cpb=dwaix&ct=dwnew&cr=dwnen&ccy=zz&csr=111011#VIO%20is%2
     0critical

•    IBM i on a POWER blade read-me-first:
     http://www.ibm.com/systems/resources/systems_power_hardware_blades_i_on_blade_readme.p
     df




33                                                                                    © 2012 IBM Corporation
Common Europe Conference – Vienna | June 2012




Trademarks
 The following are trademarks of the International Business Machines Corporation in the United States, other countries, or both.

     Not all common law marks used by IBM are listed on this page. Failure of a mark to appear does not mean that IBM does not use the mark nor does it mean that the product is not
     actively marketed or is not significant within its relevant market.
     Those trademarks followed by ® are registered trademarks of IBM in the United States; all others are trademarks or common law marks of IBM in the United States.



      For a complete list of IBM Trademarks, see www.ibm.com/legal/copytrade.shtml:

      *, AS/400®, e business(logo)®, DBE, ESCO, eServer, FICON, IBM®, IBM (logo)®, iSeries®, MVS, OS/390®, pSeries®, RS/6000®, S/30, VM/ESA®, VSE/ESA,
      WebSphere®, xSeries®, z/OS®, zSeries®, z/VM®, System i, System i5, System p, System p5, System x, System z, System z9®, BladeCenter®



 The following are trademarks or registered trademarks of other companies.

     Adobe, the Adobe logo, PostScript, and the PostScript logo are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States, and/or other countries.
     Cell Broadband Engine is a trademark of Sony Computer Entertainment, Inc. in the United States, other countries, or both and is used under license therefrom.
     Java and all Java-based trademarks are trademarks of Sun Microsystems, Inc. in the United States, other countries, or both.
     Microsoft, Windows, Windows NT, and the Windows logo are trademarks of Microsoft Corporation in the United States, other countries, or both.
     Intel, Intel logo, Intel Inside, Intel Inside logo, Intel Centrino, Intel Centrino logo, Celeron, Intel Xeon, Intel SpeedStep, Itanium, and Pentium are trademarks or registered trademarks of Intel
     Corporation or its subsidiaries in the United States and other countries.
     UNIX is a registered trademark of The Open Group in the United States and other countries.
     Linux is a registered trademark of Linus Torvalds in the United States, other countries, or both.
     ITIL is a registered trademark, and a registered community trademark of the Office of Government Commerce, and is registered in the U.S. Patent and Trademark Office.
     IT Infrastructure Library is a registered trademark of the Central Computer and Telecommunications Agency, which is now part of the Office of Government Commerce.
 * All other products may be trademarks or registered trademarks of their respective companies.

 Notes:
 Performance is in Internal Throughput Rate (ITR) ratio based on measurements and projections using standard IBM benchmarks in a controlled environment. The actual throughput that any user will
 experience will vary depending upon considerations such as the amount of multiprogramming in the user's job stream, the I/O configuration, the storage configuration, and the workload processed.
 Therefore, no assurance can be given that an individual user will achieve throughput improvements equivalent to the performance ratios stated here.
 IBM hardware products are manufactured from new parts, or new and serviceable used parts. Regardless, our warranty terms apply.
 All customer examples cited or described in this presentation are presented as illustrations of the manner in which some customers have used IBM products and the results they may have achieved. Actual
 environmental costs and performance characteristics will vary depending on individual customer configurations and conditions.
 This publication was produced in the United States. IBM may not offer the products, services or features discussed in this document in other countries, and the information may be subject to change without
 notice. Consult your local IBM business contact for information on the product or services available in your area.
 All statements regarding IBM's future direction and intent are subject to change or withdrawal without notice, and represent goals and objectives only.
 Information about non-IBM products is obtained from the manufacturers of those products or their published announcements. IBM has not tested those products and cannot confirm the performance,
 compatibility, or any other claims related to non-IBM products. Questions on the capabilities of non-IBM products should be addressed to the suppliers of those products.
 Prices subject to change without notice. Contact your IBM representative or Business Partner for the most current pricing in your geography.


34                                                                                                                                                                                          © 2012 IBM Corporation

Más contenido relacionado

La actualidad más candente

TCP/IP Stack Configuration with Configuration Assistant for IBM z/OS CS
TCP/IP Stack Configuration with Configuration Assistant for IBM z/OS CSTCP/IP Stack Configuration with Configuration Assistant for IBM z/OS CS
TCP/IP Stack Configuration with Configuration Assistant for IBM z/OS CSzOSCommserver
 
VMworld 2017 vSAN Network Design
VMworld 2017 vSAN Network Design VMworld 2017 vSAN Network Design
VMworld 2017 vSAN Network Design Cormac Hogan
 
Upgrade to IBM z/OS V2.5 technical actions
Upgrade to IBM z/OS V2.5 technical actionsUpgrade to IBM z/OS V2.5 technical actions
Upgrade to IBM z/OS V2.5 technical actionsMarna Walle
 
Brocade Administration & troubleshooting
Brocade Administration & troubleshootingBrocade Administration & troubleshooting
Brocade Administration & troubleshootingprakashjjaya
 
Introduction to ibm cloud paks concept license and minimum config public
Introduction to ibm cloud paks concept license and minimum config publicIntroduction to ibm cloud paks concept license and minimum config public
Introduction to ibm cloud paks concept license and minimum config publicPetchpaitoon Krungwong
 
vSAN Beyond The Basics
vSAN Beyond The BasicsvSAN Beyond The Basics
vSAN Beyond The BasicsSumit Lahiri
 
Deep Dive on GSLB with VMware NSX Advanced Load Balancer (Avi Networks)
Deep Dive on GSLB with VMware NSX Advanced Load Balancer (Avi Networks)Deep Dive on GSLB with VMware NSX Advanced Load Balancer (Avi Networks)
Deep Dive on GSLB with VMware NSX Advanced Load Balancer (Avi Networks)Avi Networks
 
VMware vSphere technical presentation
VMware vSphere technical presentationVMware vSphere technical presentation
VMware vSphere technical presentationaleyeldean
 
Sysplex in a Nutshell
Sysplex in a NutshellSysplex in a Nutshell
Sysplex in a NutshellzOSCommserver
 
VMware Interview questions and answers
VMware Interview questions and answersVMware Interview questions and answers
VMware Interview questions and answersvivaankumar
 
Virtual Infrastructure Overview
Virtual Infrastructure OverviewVirtual Infrastructure Overview
Virtual Infrastructure Overviewvalerian_ceaus
 
VIO LPAR Introduction | Basics | Demo
VIO LPAR Introduction | Basics | DemoVIO LPAR Introduction | Basics | Demo
VIO LPAR Introduction | Basics | DemoKernel Training
 
Introduction to Hyper-V
Introduction to Hyper-VIntroduction to Hyper-V
Introduction to Hyper-VMark Wilson
 
IBM Spectrum Scale for File and Object Storage
IBM Spectrum Scale for File and Object StorageIBM Spectrum Scale for File and Object Storage
IBM Spectrum Scale for File and Object StorageTony Pearson
 
PowerVM Live Partition Mobility in IBM PureFlex
PowerVM Live Partition Mobility in IBM PureFlexPowerVM Live Partition Mobility in IBM PureFlex
PowerVM Live Partition Mobility in IBM PureFlexLuca Comparini
 

La actualidad más candente (20)

TCP/IP Stack Configuration with Configuration Assistant for IBM z/OS CS
TCP/IP Stack Configuration with Configuration Assistant for IBM z/OS CSTCP/IP Stack Configuration with Configuration Assistant for IBM z/OS CS
TCP/IP Stack Configuration with Configuration Assistant for IBM z/OS CS
 
Hypervisors
HypervisorsHypervisors
Hypervisors
 
VMworld 2017 vSAN Network Design
VMworld 2017 vSAN Network Design VMworld 2017 vSAN Network Design
VMworld 2017 vSAN Network Design
 
Upgrade to IBM z/OS V2.5 technical actions
Upgrade to IBM z/OS V2.5 technical actionsUpgrade to IBM z/OS V2.5 technical actions
Upgrade to IBM z/OS V2.5 technical actions
 
Brocade Administration & troubleshooting
Brocade Administration & troubleshootingBrocade Administration & troubleshooting
Brocade Administration & troubleshooting
 
Introduction to ibm cloud paks concept license and minimum config public
Introduction to ibm cloud paks concept license and minimum config publicIntroduction to ibm cloud paks concept license and minimum config public
Introduction to ibm cloud paks concept license and minimum config public
 
IBM PowerVC Introduction and Configuration
IBM PowerVC Introduction and ConfigurationIBM PowerVC Introduction and Configuration
IBM PowerVC Introduction and Configuration
 
vSAN Beyond The Basics
vSAN Beyond The BasicsvSAN Beyond The Basics
vSAN Beyond The Basics
 
Deep Dive on GSLB with VMware NSX Advanced Load Balancer (Avi Networks)
Deep Dive on GSLB with VMware NSX Advanced Load Balancer (Avi Networks)Deep Dive on GSLB with VMware NSX Advanced Load Balancer (Avi Networks)
Deep Dive on GSLB with VMware NSX Advanced Load Balancer (Avi Networks)
 
Cisco ucs presentation
Cisco ucs presentationCisco ucs presentation
Cisco ucs presentation
 
VMware vSphere technical presentation
VMware vSphere technical presentationVMware vSphere technical presentation
VMware vSphere technical presentation
 
Sysplex in a Nutshell
Sysplex in a NutshellSysplex in a Nutshell
Sysplex in a Nutshell
 
VMware Interview questions and answers
VMware Interview questions and answersVMware Interview questions and answers
VMware Interview questions and answers
 
Virtual Infrastructure Overview
Virtual Infrastructure OverviewVirtual Infrastructure Overview
Virtual Infrastructure Overview
 
VIO LPAR Introduction | Basics | Demo
VIO LPAR Introduction | Basics | DemoVIO LPAR Introduction | Basics | Demo
VIO LPAR Introduction | Basics | Demo
 
Introduction to Hyper-V
Introduction to Hyper-VIntroduction to Hyper-V
Introduction to Hyper-V
 
zLinux
zLinuxzLinux
zLinux
 
OMEGAMON XE for z/OS V530 Long client presentation
OMEGAMON XE for z/OS V530 Long client presentationOMEGAMON XE for z/OS V530 Long client presentation
OMEGAMON XE for z/OS V530 Long client presentation
 
IBM Spectrum Scale for File and Object Storage
IBM Spectrum Scale for File and Object StorageIBM Spectrum Scale for File and Object Storage
IBM Spectrum Scale for File and Object Storage
 
PowerVM Live Partition Mobility in IBM PureFlex
PowerVM Live Partition Mobility in IBM PureFlexPowerVM Live Partition Mobility in IBM PureFlex
PowerVM Live Partition Mobility in IBM PureFlex
 

Destacado

How to Upgrade to IBM i 7.2
How to Upgrade to IBM i 7.2 How to Upgrade to IBM i 7.2
How to Upgrade to IBM i 7.2 HelpSystems
 
POWER VM with IBM i and live partition mobility
POWER VM with IBM i and live partition mobilityPOWER VM with IBM i and live partition mobility
POWER VM with IBM i and live partition mobilityCOMMON Europe
 
What you-need-to-know-to-do successful-upgrades
What you-need-to-know-to-do successful-upgradesWhat you-need-to-know-to-do successful-upgrades
What you-need-to-know-to-do successful-upgradesCOMMON Europe
 
AS/400 Concepts and Tools -- What you will learn
AS/400 Concepts and Tools -- What you will learnAS/400 Concepts and Tools -- What you will learn
AS/400 Concepts and Tools -- What you will learnRamesh Joshi
 
Introduction to the IBM AS/400
Introduction to the IBM AS/400Introduction to the IBM AS/400
Introduction to the IBM AS/400tvlooy
 
Virtualizzazione Power IBM
Virtualizzazione Power IBMVirtualizzazione Power IBM
Virtualizzazione Power IBMS.info Srl
 
HelpSystems - How to Upgrade to IBM i 7.3
HelpSystems - How to Upgrade to IBM i 7.3HelpSystems - How to Upgrade to IBM i 7.3
HelpSystems - How to Upgrade to IBM i 7.3HelpSystems
 
What's New in WebSphere Application Server
What's New in WebSphere Application ServerWhat's New in WebSphere Application Server
What's New in WebSphere Application ServerCOMMON Europe
 
Tips n-tricks to improve performance and reduce disk space
Tips n-tricks to improve performance and reduce disk spaceTips n-tricks to improve performance and reduce disk space
Tips n-tricks to improve performance and reduce disk spaceCOMMON Europe
 
High Availability og virtualisering, IBM Power Event
High Availability og virtualisering, IBM Power EventHigh Availability og virtualisering, IBM Power Event
High Availability og virtualisering, IBM Power EventIBM Danmark
 
Extracts from AS/400 Concepts & Tools workshop
Extracts from AS/400 Concepts & Tools workshopExtracts from AS/400 Concepts & Tools workshop
Extracts from AS/400 Concepts & Tools workshopRamesh Joshi
 
Roadmapping Product Service Combinations
Roadmapping Product Service CombinationsRoadmapping Product Service Combinations
Roadmapping Product Service CombinationsJurjen Helmus
 
IBM WebSphere Liberty and Docker Deep Dive
IBM WebSphere Liberty and Docker Deep DiveIBM WebSphere Liberty and Docker Deep Dive
IBM WebSphere Liberty and Docker Deep DiveDavid Currie
 
WebSphere Application Server Liberty Profile and Docker
WebSphere Application Server Liberty Profile and DockerWebSphere Application Server Liberty Profile and Docker
WebSphere Application Server Liberty Profile and DockerDavid Currie
 
Virtualisation overview
Virtualisation overviewVirtualisation overview
Virtualisation overviewsagaroceanic11
 
Understanding software licensing with IBM Power Systems PowerVM virtualization
Understanding software licensing with IBM Power Systems PowerVM virtualizationUnderstanding software licensing with IBM Power Systems PowerVM virtualization
Understanding software licensing with IBM Power Systems PowerVM virtualizationJay Kruemcke
 

Destacado (20)

How to Upgrade to IBM i 7.2
How to Upgrade to IBM i 7.2 How to Upgrade to IBM i 7.2
How to Upgrade to IBM i 7.2
 
POWER VM with IBM i and live partition mobility
POWER VM with IBM i and live partition mobilityPOWER VM with IBM i and live partition mobility
POWER VM with IBM i and live partition mobility
 
What you-need-to-know-to-do successful-upgrades
What you-need-to-know-to-do successful-upgradesWhat you-need-to-know-to-do successful-upgrades
What you-need-to-know-to-do successful-upgrades
 
AS/400 Concepts and Tools -- What you will learn
AS/400 Concepts and Tools -- What you will learnAS/400 Concepts and Tools -- What you will learn
AS/400 Concepts and Tools -- What you will learn
 
Introduction to the IBM AS/400
Introduction to the IBM AS/400Introduction to the IBM AS/400
Introduction to the IBM AS/400
 
Virtualizzazione Power IBM
Virtualizzazione Power IBMVirtualizzazione Power IBM
Virtualizzazione Power IBM
 
HelpSystems - How to Upgrade to IBM i 7.3
HelpSystems - How to Upgrade to IBM i 7.3HelpSystems - How to Upgrade to IBM i 7.3
HelpSystems - How to Upgrade to IBM i 7.3
 
What's New in WebSphere Application Server
What's New in WebSphere Application ServerWhat's New in WebSphere Application Server
What's New in WebSphere Application Server
 
Ha solutions su power i
Ha solutions su power iHa solutions su power i
Ha solutions su power i
 
Tips n-tricks to improve performance and reduce disk space
Tips n-tricks to improve performance and reduce disk spaceTips n-tricks to improve performance and reduce disk space
Tips n-tricks to improve performance and reduce disk space
 
High Availability og virtualisering, IBM Power Event
High Availability og virtualisering, IBM Power EventHigh Availability og virtualisering, IBM Power Event
High Availability og virtualisering, IBM Power Event
 
SAP and IBM I
SAP and IBM I SAP and IBM I
SAP and IBM I
 
Iasp Enablement
Iasp EnablementIasp Enablement
Iasp Enablement
 
Extracts from AS/400 Concepts & Tools workshop
Extracts from AS/400 Concepts & Tools workshopExtracts from AS/400 Concepts & Tools workshop
Extracts from AS/400 Concepts & Tools workshop
 
As400
As400As400
As400
 
Roadmapping Product Service Combinations
Roadmapping Product Service CombinationsRoadmapping Product Service Combinations
Roadmapping Product Service Combinations
 
IBM WebSphere Liberty and Docker Deep Dive
IBM WebSphere Liberty and Docker Deep DiveIBM WebSphere Liberty and Docker Deep Dive
IBM WebSphere Liberty and Docker Deep Dive
 
WebSphere Application Server Liberty Profile and Docker
WebSphere Application Server Liberty Profile and DockerWebSphere Application Server Liberty Profile and Docker
WebSphere Application Server Liberty Profile and Docker
 
Virtualisation overview
Virtualisation overviewVirtualisation overview
Virtualisation overview
 
Understanding software licensing with IBM Power Systems PowerVM virtualization
Understanding software licensing with IBM Power Systems PowerVM virtualizationUnderstanding software licensing with IBM Power Systems PowerVM virtualization
Understanding software licensing with IBM Power Systems PowerVM virtualization
 

Similar a VIOS in Action with IBM i

Merge the power with VMware
Merge the power with VMwareMerge the power with VMware
Merge the power with VMwareCOMMON Europe
 
Presentation power vm virtualization without limits
Presentation   power vm virtualization without limitsPresentation   power vm virtualization without limits
Presentation power vm virtualization without limitssolarisyougood
 
Hyper V And Scvmm Best Practis
Hyper V And Scvmm Best PractisHyper V And Scvmm Best Practis
Hyper V And Scvmm Best PractisBlauge
 
Virtualization Technology and Directions ( EMC World 2010 )
Virtualization Technology and Directions ( EMC World 2010 )Virtualization Technology and Directions ( EMC World 2010 )
Virtualization Technology and Directions ( EMC World 2010 )EMC
 
Ready for cloud computing with hyper v
Ready for cloud computing with hyper vReady for cloud computing with hyper v
Ready for cloud computing with hyper vAndik Susilo
 
Dynamic Data Center for Hosters, by Stefan Simon
Dynamic Data Center for Hosters, by Stefan SimonDynamic Data Center for Hosters, by Stefan Simon
Dynamic Data Center for Hosters, by Stefan SimonAlexey Kovyazin
 
Storage Developer Conference - 09/19/2012
Storage Developer Conference - 09/19/2012Storage Developer Conference - 09/19/2012
Storage Developer Conference - 09/19/2012Ceph Community
 
Windows server 8 and hyper v
Windows server 8 and hyper vWindows server 8 and hyper v
Windows server 8 and hyper vSusantha Silva
 
The Storage Hypervisor: The missing link for the Software Defined Datacenter
The Storage Hypervisor:  The missing link for the Software Defined Datacenter The Storage Hypervisor:  The missing link for the Software Defined Datacenter
The Storage Hypervisor: The missing link for the Software Defined Datacenter Virsto Software
 
Integrating x86 Applications into Linux on System z Environments
Integrating x86 Applications into Linux on System z EnvironmentsIntegrating x86 Applications into Linux on System z Environments
Integrating x86 Applications into Linux on System z EnvironmentsIBM India Smarter Computing
 
Presentation cloud computing workshop - virtualization
Presentation   cloud computing workshop - virtualizationPresentation   cloud computing workshop - virtualization
Presentation cloud computing workshop - virtualizationxKinAnx
 
Windows server 8 hyper v & storage (hans vredevoort)
Windows server 8 hyper v & storage (hans vredevoort)Windows server 8 hyper v & storage (hans vredevoort)
Windows server 8 hyper v & storage (hans vredevoort)hypervnu
 
Building a Distributed Block Storage System on Xen
Building a Distributed Block Storage System on XenBuilding a Distributed Block Storage System on Xen
Building a Distributed Block Storage System on XenThe Linux Foundation
 
White Paper Why Use 16Gb Fibre Channel with Windows Server 2012 Deployments
White Paper Why Use 16Gb Fibre Channel with Windows Server 2012 DeploymentsWhite Paper Why Use 16Gb Fibre Channel with Windows Server 2012 Deployments
White Paper Why Use 16Gb Fibre Channel with Windows Server 2012 DeploymentsTũi Wichets
 
Hyper V in Windows Server 2012
Hyper V in Windows Server 2012Hyper V in Windows Server 2012
Hyper V in Windows Server 2012Lai Yoong Seng
 

Similar a VIOS in Action with IBM i (20)

VPM in action
VPM in actionVPM in action
VPM in action
 
Merge the power with VMware
Merge the power with VMwareMerge the power with VMware
Merge the power with VMware
 
Presentation power vm virtualization without limits
Presentation   power vm virtualization without limitsPresentation   power vm virtualization without limits
Presentation power vm virtualization without limits
 
Windows 8 Hyper-V: Availability
Windows 8 Hyper-V: AvailabilityWindows 8 Hyper-V: Availability
Windows 8 Hyper-V: Availability
 
Hyper V And Scvmm Best Practis
Hyper V And Scvmm Best PractisHyper V And Scvmm Best Practis
Hyper V And Scvmm Best Practis
 
Virtualization Technology and Directions ( EMC World 2010 )
Virtualization Technology and Directions ( EMC World 2010 )Virtualization Technology and Directions ( EMC World 2010 )
Virtualization Technology and Directions ( EMC World 2010 )
 
Ready for cloud computing with hyper v
Ready for cloud computing with hyper vReady for cloud computing with hyper v
Ready for cloud computing with hyper v
 
Dynamic Data Center for Hosters, by Stefan Simon
Dynamic Data Center for Hosters, by Stefan SimonDynamic Data Center for Hosters, by Stefan Simon
Dynamic Data Center for Hosters, by Stefan Simon
 
Storage Developer Conference - 09/19/2012
Storage Developer Conference - 09/19/2012Storage Developer Conference - 09/19/2012
Storage Developer Conference - 09/19/2012
 
Windows server 8 and hyper v
Windows server 8 and hyper vWindows server 8 and hyper v
Windows server 8 and hyper v
 
The Storage Hypervisor: The missing link for the Software Defined Datacenter
The Storage Hypervisor:  The missing link for the Software Defined Datacenter The Storage Hypervisor:  The missing link for the Software Defined Datacenter
The Storage Hypervisor: The missing link for the Software Defined Datacenter
 
Hyper-v Storage
Hyper-v StorageHyper-v Storage
Hyper-v Storage
 
Integrating x86 Applications into Linux on System z Environments
Integrating x86 Applications into Linux on System z EnvironmentsIntegrating x86 Applications into Linux on System z Environments
Integrating x86 Applications into Linux on System z Environments
 
Presentation cloud computing workshop - virtualization
Presentation   cloud computing workshop - virtualizationPresentation   cloud computing workshop - virtualization
Presentation cloud computing workshop - virtualization
 
Windows server 8 hyper v & storage (hans vredevoort)
Windows server 8 hyper v & storage (hans vredevoort)Windows server 8 hyper v & storage (hans vredevoort)
Windows server 8 hyper v & storage (hans vredevoort)
 
Microsoft Hyper-V
Microsoft Hyper-VMicrosoft Hyper-V
Microsoft Hyper-V
 
Building a Distributed Block Storage System on Xen
Building a Distributed Block Storage System on XenBuilding a Distributed Block Storage System on Xen
Building a Distributed Block Storage System on Xen
 
White Paper Why Use 16Gb Fibre Channel with Windows Server 2012 Deployments
White Paper Why Use 16Gb Fibre Channel with Windows Server 2012 DeploymentsWhite Paper Why Use 16Gb Fibre Channel with Windows Server 2012 Deployments
White Paper Why Use 16Gb Fibre Channel with Windows Server 2012 Deployments
 
What’s new System Center 2012 SP1, VMM
What’s new System Center 2012 SP1, VMMWhat’s new System Center 2012 SP1, VMM
What’s new System Center 2012 SP1, VMM
 
Hyper V in Windows Server 2012
Hyper V in Windows Server 2012Hyper V in Windows Server 2012
Hyper V in Windows Server 2012
 

Más de COMMON Europe

Compiling the Compiler
Compiling the CompilerCompiling the Compiler
Compiling the CompilerCOMMON Europe
 
Workload Groups overview updates
Workload Groups overview updatesWorkload Groups overview updates
Workload Groups overview updatesCOMMON Europe
 
Why i - Common Europe 2012
Why i - Common Europe 2012Why i - Common Europe 2012
Why i - Common Europe 2012COMMON Europe
 
The Ruby OpenSSL extension
The Ruby OpenSSL extensionThe Ruby OpenSSL extension
The Ruby OpenSSL extensionCOMMON Europe
 
Using Ruby on IBM i (i5/OS)
Using Ruby on IBM i (i5/OS)Using Ruby on IBM i (i5/OS)
Using Ruby on IBM i (i5/OS)COMMON Europe
 
IBM Systems Director Navigator for i
IBM Systems Director Navigator for iIBM Systems Director Navigator for i
IBM Systems Director Navigator for iCOMMON Europe
 
IBM i Trends & Directions Common Europe 2012
IBM i Trends & Directions Common Europe 2012IBM i Trends & Directions Common Europe 2012
IBM i Trends & Directions Common Europe 2012COMMON Europe
 
IBM i Technology Refreshes Overview 2012 06-04
IBM i Technology Refreshes Overview 2012 06-04IBM i Technology Refreshes Overview 2012 06-04
IBM i Technology Refreshes Overview 2012 06-04COMMON Europe
 
IBM i 7.1 & TRs CEC 2012
IBM i 7.1 & TRs CEC 2012IBM i 7.1 & TRs CEC 2012
IBM i 7.1 & TRs CEC 2012COMMON Europe
 
DB2 Web Query whats new
DB2 Web Query whats newDB2 Web Query whats new
DB2 Web Query whats newCOMMON Europe
 
Access client solutions overview
Access client solutions overviewAccess client solutions overview
Access client solutions overviewCOMMON Europe
 
What's new with Zend server
What's new with Zend serverWhat's new with Zend server
What's new with Zend serverCOMMON Europe
 
Php arrays for RPG programmers
Php arrays for RPG programmersPhp arrays for RPG programmers
Php arrays for RPG programmersCOMMON Europe
 
Open source report writing tools for IBM i Vienna 2012
Open source report writing tools for IBM i  Vienna 2012Open source report writing tools for IBM i  Vienna 2012
Open source report writing tools for IBM i Vienna 2012COMMON Europe
 
Moving 5.4 to 7.1 AB
Moving 5.4 to 7.1 ABMoving 5.4 to 7.1 AB
Moving 5.4 to 7.1 ABCOMMON Europe
 
Introduction to My SQL
Introduction to My SQLIntroduction to My SQL
Introduction to My SQLCOMMON Europe
 
IBM CEC 2012 Storage june 11, 2012
IBM CEC 2012 Storage june 11, 2012IBM CEC 2012 Storage june 11, 2012
IBM CEC 2012 Storage june 11, 2012COMMON Europe
 
Getting started with PHP on IBM i
Getting started with PHP on IBM iGetting started with PHP on IBM i
Getting started with PHP on IBM iCOMMON Europe
 
Developing mobile applications for i using open source tools Venna 2012
Developing mobile applications for i using open source tools  Venna 2012Developing mobile applications for i using open source tools  Venna 2012
Developing mobile applications for i using open source tools Venna 2012COMMON Europe
 

Más de COMMON Europe (20)

Compiling the Compiler
Compiling the CompilerCompiling the Compiler
Compiling the Compiler
 
Workload Groups overview updates
Workload Groups overview updatesWorkload Groups overview updates
Workload Groups overview updates
 
Why i - Common Europe 2012
Why i - Common Europe 2012Why i - Common Europe 2012
Why i - Common Europe 2012
 
The Ruby OpenSSL extension
The Ruby OpenSSL extensionThe Ruby OpenSSL extension
The Ruby OpenSSL extension
 
Using Ruby on IBM i (i5/OS)
Using Ruby on IBM i (i5/OS)Using Ruby on IBM i (i5/OS)
Using Ruby on IBM i (i5/OS)
 
IBM Systems Director Navigator for i
IBM Systems Director Navigator for iIBM Systems Director Navigator for i
IBM Systems Director Navigator for i
 
IBM i Trends & Directions Common Europe 2012
IBM i Trends & Directions Common Europe 2012IBM i Trends & Directions Common Europe 2012
IBM i Trends & Directions Common Europe 2012
 
IBM i Technology Refreshes Overview 2012 06-04
IBM i Technology Refreshes Overview 2012 06-04IBM i Technology Refreshes Overview 2012 06-04
IBM i Technology Refreshes Overview 2012 06-04
 
IBM i 7.1 & TRs CEC 2012
IBM i 7.1 & TRs CEC 2012IBM i 7.1 & TRs CEC 2012
IBM i 7.1 & TRs CEC 2012
 
DB2 Web Query whats new
DB2 Web Query whats newDB2 Web Query whats new
DB2 Web Query whats new
 
Access client solutions overview
Access client solutions overviewAccess client solutions overview
Access client solutions overview
 
What's new with Zend server
What's new with Zend serverWhat's new with Zend server
What's new with Zend server
 
RPG investment
RPG investmentRPG investment
RPG investment
 
Php arrays for RPG programmers
Php arrays for RPG programmersPhp arrays for RPG programmers
Php arrays for RPG programmers
 
Open source report writing tools for IBM i Vienna 2012
Open source report writing tools for IBM i  Vienna 2012Open source report writing tools for IBM i  Vienna 2012
Open source report writing tools for IBM i Vienna 2012
 
Moving 5.4 to 7.1 AB
Moving 5.4 to 7.1 ABMoving 5.4 to 7.1 AB
Moving 5.4 to 7.1 AB
 
Introduction to My SQL
Introduction to My SQLIntroduction to My SQL
Introduction to My SQL
 
IBM CEC 2012 Storage june 11, 2012
IBM CEC 2012 Storage june 11, 2012IBM CEC 2012 Storage june 11, 2012
IBM CEC 2012 Storage june 11, 2012
 
Getting started with PHP on IBM i
Getting started with PHP on IBM iGetting started with PHP on IBM i
Getting started with PHP on IBM i
 
Developing mobile applications for i using open source tools Venna 2012
Developing mobile applications for i using open source tools  Venna 2012Developing mobile applications for i using open source tools  Venna 2012
Developing mobile applications for i using open source tools Venna 2012
 

Último

Salesforce Community Group Quito, Salesforce 101
Salesforce Community Group Quito, Salesforce 101Salesforce Community Group Quito, Salesforce 101
Salesforce Community Group Quito, Salesforce 101Paola De la Torre
 
Top 5 Benefits OF Using Muvi Live Paywall For Live Streams
Top 5 Benefits OF Using Muvi Live Paywall For Live StreamsTop 5 Benefits OF Using Muvi Live Paywall For Live Streams
Top 5 Benefits OF Using Muvi Live Paywall For Live StreamsRoshan Dwivedi
 
Handwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsHandwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsMaria Levchenko
 
Automating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps ScriptAutomating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps Scriptwesley chun
 
08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking MenDelhi Call girls
 
Data Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt RobisonData Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt RobisonAnna Loughnan Colquhoun
 
Partners Life - Insurer Innovation Award 2024
Partners Life - Insurer Innovation Award 2024Partners Life - Insurer Innovation Award 2024
Partners Life - Insurer Innovation Award 2024The Digital Insurer
 
08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking Men08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking MenDelhi Call girls
 
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Drew Madelung
 
Exploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone ProcessorsExploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone Processorsdebabhi2
 
Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...Enterprise Knowledge
 
WhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure service
WhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure serviceWhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure service
WhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure servicePooja Nehwal
 
Factors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptxFactors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptxKatpro Technologies
 
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...gurkirankumar98700
 
08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking Men08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking MenDelhi Call girls
 
Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024The Digital Insurer
 
Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024The Digital Insurer
 
Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024The Digital Insurer
 
2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...Martijn de Jong
 
A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)Gabriella Davis
 

Último (20)

Salesforce Community Group Quito, Salesforce 101
Salesforce Community Group Quito, Salesforce 101Salesforce Community Group Quito, Salesforce 101
Salesforce Community Group Quito, Salesforce 101
 
Top 5 Benefits OF Using Muvi Live Paywall For Live Streams
Top 5 Benefits OF Using Muvi Live Paywall For Live StreamsTop 5 Benefits OF Using Muvi Live Paywall For Live Streams
Top 5 Benefits OF Using Muvi Live Paywall For Live Streams
 
Handwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsHandwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed texts
 
Automating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps ScriptAutomating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps Script
 
08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men
 
Data Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt RobisonData Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt Robison
 
Partners Life - Insurer Innovation Award 2024
Partners Life - Insurer Innovation Award 2024Partners Life - Insurer Innovation Award 2024
Partners Life - Insurer Innovation Award 2024
 
08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking Men08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking Men
 
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
 
Exploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone ProcessorsExploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone Processors
 
Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...
 
WhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure service
WhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure serviceWhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure service
WhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure service
 
Factors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptxFactors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptx
 
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...
 
08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking Men08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking Men
 
Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024
 
Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024
 
Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024
 
2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...
 
A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)
 

VIOS in Action with IBM i

  • 1. Common Europe Conference – Vienna | June 2012 VIOS in Action with IBM i Janus Hertz Senior IT Specialist IBM EMEA ETS Center of Competency for Power Systems Rev. 10-06-2012 © 2012 IBM Corporation
  • 2. Common Europe Conference – Vienna | June 2012 What is the VIOS? A special purpose appliance partition – Provide I/O virtualization – Advanced Partition Virtualization enabler First GAed 2004 Built on top of AIX, but not an AIX partition IBM i first attached to VIOS in 2008 with the IBM i 6.1 VIOS is licensed with PowerVM 2 © 2012 IBM Corporation
  • 3. Common Europe Conference – Vienna | June 2012 Where Do I Start with Installing VIOS and IBM i on Power system? • Latest version at: http://www.ibm.com/systems/resources/systems_i_Virtualization_Open_Storage.pdf 3 © 2012 IBM Corporation
  • 4. Common Europe Conference – Vienna | June 2012 I/O Virtualization on POWER IO Bus Virtualization IO Adapter Virtualization with Dedicated Adapters with VIO Server VIOS LPAR LPAR A LPAR B LPAR A LPAR B Physical Physical Adapter Adapter Physical DevDrv DevDrv Adapter Virtual Virtual Virtual Virtual Increasing Adapter Adapter Adapter Adapter DevDrv Server Server DevDrv DevDrv Adapter BW & LPAR Hypervisor Density per Slot Virtual Fabric Hypervisor Func Func PCI adapter PCI adapter Func Port Port PCI adapter Port Fabric Fabric 4 © 2012 IBM Corporation
  • 5. Common Europe Conference – Vienna | June 2012 IBM i + VSCSI (Classic) Source System 1 VIOS IBM i Client IBM i Client IBM i Client (System 1) (System 2) (System 3) System 2 FC HBA System 3 6B22 6B22 6B22 Device Device Device •Assign storage to the physical HBA Type Type Type in the VIOS •Hostconnect is created as an open storage or AIX hosttype, •Requires 512 byte per sector LUNs to be assigned to the hostconnect •Cannot Migrate existing direct connect LUNs Hypervisor •Many Storage options supported POWER6 with IBM i 6.1.1 5 © 2012 IBM Corporation
  • 6. Common Europe Conference – Vienna | June 2012 IBM i + VSCSI (Classic) Storage Virtualizer VIOS IBM i Client •Storage is assigned to the VIOS partition •Within the VIOS you FC HBA map the hdisk (lun) to the vhost corresponding to the client partition 6B22 •Storage management Device allocation is done from Type vhostXXX hdisk1 both the external storage hdisk2 box and the VIOS VSCSI VSCSI SERVER Client •Flexible disk sizes up to 2Tb -512 •16 disks per vscsi Hypervisor adapter POWER6 with IBM i 6.1.1 6 © 2012 IBM Corporation
  • 7. Common Europe Conference – Vienna | June 2012 IBM i + VSCSI Tape and optical VIOS IBM i Client •Storage is assigned to the VIOS partition CD1 OPT01 •Within the VIOS you map physical tape or optical or file backed RMT1 TAP01 virtual optical to the vhost corresponding to vhostXXX cd1 the client partition rmt1 •No tape library support with vscsi adpaters. VSCSI VSCSI Must use VFC adapers. SERVER Client Hypervisor POWER6 with IBM i 6.1.1 7 © 2012 IBM Corporation
  • 8. Common Europe Conference – Vienna | June 2012 IBM i + NPIV ( Virtual Fiber Chanel ) Source System 1 VIOS IBM i Client IBM i Client IBM i Client (System 1) (System 1) (System 1) System 2 8Gbs HBA System 3 •Hypervisor assigns 2 unique WWPNs to each Virtual fiber Virtual address example C001234567890001 •Hostconnect is created as an iSeries hosttype, Hypervisor •Requires 520 byte per sector LUNs POWER6 with IBM i 6.1.1 to be assigned to the iSeries hostconnect on DS8K •Can Migrate existing direct connect LUNS •DS8100, DS8300, DS8700, Note: an NPIV ( N_port ) capable switch is required to connect the DS8800, DS5100 and DS5300 VIOS to the DS8000 to use virtual fiber. supported 8 © 2012 IBM Corporation
  • 9. Common Europe Conference – Vienna | June 2012 NPIV Configuration - Limitations Single client adapter per physical port per partition – Intended to avoid single point of failure – Documentation only – not enforced Maximum of 64 active client connections per physical port – It is possible to map more than 64 clients to a single adapter port – May be less due to other VIOS resource constraints 32K unique WWPN pairs per system platform – Removing adapter does not reclaim WWPNs Can be manually reclaimed through CLI (mksyscfg, chhwres ) “virtual_fc_adapters” attribute – If exhausted, need to purchase activation code for more Device Limitations – Maximum of 128 visible target ports Not all visible target ports will necessarily be active Redundant paths to a single DS8000 node Device level port configuration Inactive target ports still require client adapter resources – Maximum of 64 target devices Any combination of disk and tape Tape libraries and tape drives are counted separately 9 © 2012 IBM Corporation
  • 10. Common Europe Conference – Vienna | June 2012 Redundant VIOS with NPIV POWER6 Step 1: configure virtual and physical FC adapters – Best Practice to make VIOS redundant or separate individual VIOS partitions where a IBM i single hardware failure would not take down Client IASP SYSBAS both VIOS partitions. VFC adapters Server VFC Step 2: configure SAN fabric and storage adapters – Zone Luns to the virtual WWPNs. – Each DASD sees a path through 2 VIOS partitions 1 VIOS VIOS •Notes: Support up to 8 paths per LUN •Not all paths have to go through separate VIOS partitions. •New multi-path algorithm in 7.1 TR2 2 Physical FC connections 10 © 2012 IBM Corporation
  • 11. Common Europe Conference – Vienna | June 2012 6B25 Adapter Look & Feel Similar in look & feel to other IOPless storage adapters Attached device resources have real hardware CCINs 11 © 2012 IBM Corporation
  • 12. Common Europe Conference – Vienna | June 2012 Support for IBM Storage Systems with IBM i DS3200 DS4700 Table as of N Series DS3400 Storwize DS5100 DS8100 DS8700 DS4800 DS6800 SVC XIV April 5, 2011 @@ DS3500 V7000 DS5300 DS8300 DS8800 DS5020 DS3950 6.1 / 7.1 5.4 / 6.1 IBM i POWER6/7 POWER5/6/7 5.4 / 6.1 / 7.1 6.1 / 7.1 6.1 / 7.1 6.1 / 7.1 6.1 / 7.1 6.1 / 7.1 5.4 / 6.1 / 7.1 5.4 / 6.1 / 7.1 Version Rack / POWER5/6/7 POWER6/7 POWER6/7 POWER6/7 POWER6/7 POWER6/7 POWER5/6/7 POWER5/6/7 Hardware Not DS3200#, Not 7.1 ### Tower Yes DS3500## POWER5/6/7 Systems Direct* or VIOS Direct or VIOS – Direct or VIOS – IBM i IFS / NFS VIOS VIOS VIOS –VSCSI and Direct VIOS VIOS VSCSI and VSCSI and Attach (NAS) NPIV% NPIV** NPIV** 6.1 / 7.1 6.1 / 7.1 IBM i 6.1 / 7.1 6.1 / 7.1 6.1 / 7.1 6.1 / 7.1 6.1 / 7.1 6.1 / 7.1 6.1 / 7.1 POWER6/7 POWER6/7 @, Not Version POWER6/7 POWER6/7 POWER6/7 POWER6/7 POWER6/7 POWER6/7 POWER6/7 IFS / NFS #, ## supported Power Hardware (BCH) (BCH) (BCH) (BCH) (BCH) (BCH) (BCH) Blades (NAS) IBM i IFS VIOS VIOS VIOS VIOS VIOS VIOS n/a VIOS VIOS Attach (NAS) NPIV** NPIV** Notes - This table does not list more detailed considerations, for example required levels of firmware or PTFs required or configuration performance considerations - POWER7 servers require IBM i 6.1 or later - This table can change over time as addition hardware/software capabilities/options are added # DS3200 only supports SAS connection, not supported on Rack/Tower servers which use only Fibre Channel connections, supported on Blades with SAS ## DS3500 has either SAS or Fibre Channel connection. Ractk/Tower only uses Fibre Channel. Blades support either SAS or Fibre Channel (either BCS or BCH) ### Not supported on IBM i 7.1. But see SCORE System RPQ 846-15284 for exception support * Supported with Smart Fibre Channel adapters – NOT supported with IOP-based Fibre Channel adapters ** NPIV requires Machine Code Level of 6.1.1 or later and requires NPIV capable HBAs (FC adapters) and switches @ BCH supports DS3400, DS3500, DS3950 & BCS supports DS3200, DS3500 @@ N Series can only be used as file server. No load source/boot support. Support only through IFS. No IBM i data base support % NPIV support for DS5100/DS5300 requires IBM i 7.1 TR2 and must have POWER7 firmware: Ax730_xxx or the POWER6 firmware Service Pack that will be released 2Q2011 For more details, use the System Storage Interoperability Center: www.ibm.com/systems/support/storage/config/ssic/ Note there are currently some differences between the above table and the SSIC. The SSIC should be updated to reflect the above information 12 © 2012 IBM Corporation
  • 13. Common Europe Conference – Vienna | June 2012 IBM PowerVM Virtual Ethernet Virtual I/O Server Client 1 Client 2 Shared PowerVM Ethernet switch Ethernet Adapter – Part of PowerVM Hypervisor ent ent CMN CMN – Moves data between LPARs (Phy) (Vir) (Vir) (Vir) Shared Ethernet Adapter VLAN-Aware Ethernet Switch PowerVM Hypervisor – Part of the VIO server – Logical device Ethernet – Bridges traffic to and from Switch external networks Additional capabilities – VLAN aware – Link aggregation for external networks – SEA Failover for redundancy 13 © 2012 IBM Corporation
  • 14. Common Europe Conference – Vienna | June 2012 SEA Failover Configuration VIOS VIOS Partition Partition SEA SEA VETH VETH VETH VETH VETH VETH VETH ETH ETH Hypervisor Client Network network 14 © 2012 IBM Corporation
  • 15. Common Europe Conference – Vienna | June 2012 Virtual Ethernet Limits Description Limit Maximum virtual Ethernet adapters per LPAR 256 Maximum number of VLANs per virtual adapter 21 VLAN (20 VID, 1 PVID) Number of virtual adapter per single SEA sharing a single physical network adapter 16 Maximum number of VLAN IDs 4094 Maximum number of physical adapters in a link aggregation 8 primary, 1 backup 15 © 2012 IBM Corporation
  • 16. Common Europe Conference – Vienna | June 2012 PowerVM Active Memory Sharing Reduce memory costs by improving memory utilization on Power Servers Supports over-commitment of logical memory with overflow going to a paging device POWER Server Intelligently flow memory from one partition to Virtual another for increased utilization and flexibility I/O Dedicated Server Memory Shared Memory Memory from a shared physical memory pool is dynamically allocated among logical partitions as needed to optimize overall memory usage CPU Shared CPU Designed for partitions with variable memory requirements Paging PowerVM Enterprise Edition on POWER6 and PowerVM Hypervisor AMS Power7 processor-based systems – Partitions must use VIOS for I/O virtualization Make sure it’s a good fit for you! 16 * All statements regarding IBM's future direction and intent are subject to change or © 2012 IBM Corporation withdrawal without notice, and represent goals and objectives only.
  • 17. Common Europe Conference – Vienna | June 2012 LPAR Suspend/Resume – Customer Value Resource balancing for long-running batch jobs – e.g. suspend lower priority and/or long running workloads to free resources. Planned CEC outages for maintenance/upgrades – Suspend/resume may be used in place of or in conjunction with partition mobility. – Suspend/resume may require less time and effort than manual database shutdown and restart, for example. Requirements: • All I/O is virtualized • HMC version 7 releases 7.3 • FW: Ax730_xxx • IBM i 7.1 TR2 • VIOS 2.2.1.0 FP24 SP2 17 © 2012 IBM Corporation
  • 18. Common Europe Conference – Vienna | June 2012 Partition Suspend/Resume Partition Suspend/Resume supported on POWER7 IBM i 7.1 TR2 Power7 System #1 Storage Suspended Partition IBM i Client 1 Subsystem Validate environment for appropriate resources A en0 Ask partiton if it’s (if) ready for suspend vscsi0 ent1 Suspend Partition ReservedStorage Pool CPU and I/O LUN M M M M M M Move Memory and CPU VLAN to Storage Pool C C C Hypervisor Partition Suspended VASI vhost0 ent1 A Mover ent2 en2 Service vtscsi0 SEA (if) fcs0 ent0 VIOS 18 © 2012 IBM Corporation
  • 19. Common Europe Conference – Vienna | June 2012 PowerVM Live Partition Mobility • Move running partition from one system to Live Partition Mobility another with almost no impact to end users • Requires POWER7 systems or later, PowerVM Enterprise, and all I/O must be through the Movement of the OS and Virtual I/O Server applications to a different server with no loss of service • Requires IBM i 7.1 with TR4 Virtualized storage and Network Infrastructure Potential Benefits • Eliminate planned outages • Balance workloads across systems • Energy Savings 19 © 2012 IBM Corporation
  • 20. Common Europe Conference – Vienna | June 2012 Requirements & Planning Source and destination must be mobility capable and compatible. – Enhanced hardware virtualization capabilities. – Identical or compatible processors. HMC – Compatible firmware levels. Source and destination must be LAN connected – same subnet. LAN All resources (CPU, Memory, IO adapters) must be LPAR virtualized prior to migration. – Hypervisor will handle CPU and Memory automatically, as required. Virtual IO adapters SAN are pre-configured, and SAN-attached disks accessed through Virtual IO Server (VIOS) Boot Source and destination VIOS must have symmetrical access Paging to the partition’s disks. Application Data – e.g. no internal or VIOS LVM-based disks. OS is migration enabled/aware. – Certain tools/middleware can benefit from being migration aware also. 20 © 2012 IBM Corporation
  • 21. Common Europe Conference – Vienna | June 2012 Live Partition Mobility Partition Mobility supported on POWER7 IBM i 7.1 TR Power7 System #1 Power7 System #2 Suspended Partition IBM i Client 1 Shelli Partition IBM Client 1 Once enough memory Finish the migration M M M M M M M Validate environment M M M M M M M Create removebeen Createshell partition pages virtual SCSI Start have the and migrating for appropriate moved, suspend the on target system memory pages original LPAR devices resources en0 source system definitions en0 A (if) (if) A vscsi0 ent1 ent1 vscsi0 HMC VLAN VLAN Hypervisor Hypervisor VASI vhost0 ent1 ent1 vhost0 VASI Mover ent2 en2 en2 ent2 Mover Service vtscsi0 vtscsi0 Service SEA (if) (if) SEA fcs0 ent0 VIOS VIOS ent0 fcs0 Storage Subsystem A 21 © 2012 IBM Corporation
  • 22. Common Europe Conference – Vienna | June 2012 Installing VIOS PowerVM Standard or Enterprise Edition must be ordered – VIOS install media migration utility install image – activation code Partition Creation – physical adapters – virtual adapters Partition Activation to SMS DVD Install – Can also install over network – NIM Server Post-Install Tasks 22 © 2012 IBM Corporation
  • 23. Common Europe Conference – Vienna | June 2012 Check VIOS enablement In HMC, display managed system’s properties 23 © 2012 IBM Corporation
  • 24. Common Europe Conference – Vienna | June 2012 VIOS enablement Select managed system Capacity on demand Advanced POWER virtualization (now PowerVM) Enter 32-digit enablement code 24 © 2012 IBM Corporation
  • 25. Common Europe Conference – Vienna | June 2012 LPAR configuration – create a partition 25 © 2012 IBM Corporation
  • 26. Common Europe Conference – Vienna | June 2012 VIOS partition configuration – physical IO 26 © 2012 IBM Corporation
  • 27. Common Europe Conference – Vienna | June 2012 VIOS install: SMS setup When the partition is powered on, the PFW screen will appear Hit 1 to enter the SMS menu and set up the install source for VIOS 27 © 2012 IBM Corporation
  • 28. Common Europe Conference – Vienna | June 2012 VIOS install: Select Install/Boot Device Select option 5, then option 1 28 © 2012 IBM Corporation
  • 29. Common Europe Conference – Vienna | June 2012 VIOS install: Select DVD as boot device 29 © 2012 IBM Corporation
  • 30. Common Europe Conference – Vienna | June 2012 VIOS install: verify disk unit Choose option 2 to verify VIOS is going to be installed on the correct disk unit 30 © 2012 IBM Corporation
  • 31. Common Europe Conference – Vienna | June 2012 VIOS install: verify disk unit hdisk0 is the first physical disk or LUN detected VIOS can be installed on mirrored integrated disk, or installed on the SAN 31 © 2012 IBM Corporation
  • 32. Power Virtualization IBM i and BladeCenter S Common Europe Conference – Vienna | June 2012 System & Metode, Denmark www.system-method.com • IBM Business Partner • Software Solutions & Hosting company Focuses on very small / old existing installations • 1 BladeCenter S chassis • 1 JS12 POWER6 blade • 2 HS21 x86 blades • Provides hosting services to several clients/companies • 1 IBM Virtual IO Server 2.2 (VIOS) host LPAR • 9 IBM i 6.1 client LPARs – for different customers Pros: • Cheap hardware compared to traditional Power servers • Possible to get customers that would potentially have switched to the “dark side ” • Flexible Cons: • More complex, requires three different skills sets (Blade, VIOS, IBM i) 32 © 2012 IBM Corporation
  • 33. Common Europe Conference – Vienna | June 2012 References: • PowerVM Quicksheet - http://tablespace.net/quicksheet/powervm-quicksheet.pdf • PowerVM Quickstart - http://tablespace.net/quicksheet/powervm-quickstart.html • VIOS Cheat Sheet - http://www.ibm.com/developerworks/aix/library/au- viocheatsheet/index.html?ca=drs- • Get to know the VIOS CLI - http://www.ibm.com/developerworks/aix/library/au- vioscli/index.html?cmp=dw&cpb=dwaix&ct=dwnew&cr=dwnen&ccy=zz&csr=111011#VIO%20is%2 0critical • IBM i on a POWER blade read-me-first: http://www.ibm.com/systems/resources/systems_power_hardware_blades_i_on_blade_readme.p df 33 © 2012 IBM Corporation
  • 34. Common Europe Conference – Vienna | June 2012 Trademarks The following are trademarks of the International Business Machines Corporation in the United States, other countries, or both. Not all common law marks used by IBM are listed on this page. Failure of a mark to appear does not mean that IBM does not use the mark nor does it mean that the product is not actively marketed or is not significant within its relevant market. Those trademarks followed by ® are registered trademarks of IBM in the United States; all others are trademarks or common law marks of IBM in the United States. For a complete list of IBM Trademarks, see www.ibm.com/legal/copytrade.shtml: *, AS/400®, e business(logo)®, DBE, ESCO, eServer, FICON, IBM®, IBM (logo)®, iSeries®, MVS, OS/390®, pSeries®, RS/6000®, S/30, VM/ESA®, VSE/ESA, WebSphere®, xSeries®, z/OS®, zSeries®, z/VM®, System i, System i5, System p, System p5, System x, System z, System z9®, BladeCenter® The following are trademarks or registered trademarks of other companies. Adobe, the Adobe logo, PostScript, and the PostScript logo are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States, and/or other countries. Cell Broadband Engine is a trademark of Sony Computer Entertainment, Inc. in the United States, other countries, or both and is used under license therefrom. Java and all Java-based trademarks are trademarks of Sun Microsystems, Inc. in the United States, other countries, or both. Microsoft, Windows, Windows NT, and the Windows logo are trademarks of Microsoft Corporation in the United States, other countries, or both. Intel, Intel logo, Intel Inside, Intel Inside logo, Intel Centrino, Intel Centrino logo, Celeron, Intel Xeon, Intel SpeedStep, Itanium, and Pentium are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. UNIX is a registered trademark of The Open Group in the United States and other countries. Linux is a registered trademark of Linus Torvalds in the United States, other countries, or both. ITIL is a registered trademark, and a registered community trademark of the Office of Government Commerce, and is registered in the U.S. Patent and Trademark Office. IT Infrastructure Library is a registered trademark of the Central Computer and Telecommunications Agency, which is now part of the Office of Government Commerce. * All other products may be trademarks or registered trademarks of their respective companies. Notes: Performance is in Internal Throughput Rate (ITR) ratio based on measurements and projections using standard IBM benchmarks in a controlled environment. The actual throughput that any user will experience will vary depending upon considerations such as the amount of multiprogramming in the user's job stream, the I/O configuration, the storage configuration, and the workload processed. Therefore, no assurance can be given that an individual user will achieve throughput improvements equivalent to the performance ratios stated here. IBM hardware products are manufactured from new parts, or new and serviceable used parts. Regardless, our warranty terms apply. All customer examples cited or described in this presentation are presented as illustrations of the manner in which some customers have used IBM products and the results they may have achieved. Actual environmental costs and performance characteristics will vary depending on individual customer configurations and conditions. This publication was produced in the United States. IBM may not offer the products, services or features discussed in this document in other countries, and the information may be subject to change without notice. Consult your local IBM business contact for information on the product or services available in your area. All statements regarding IBM's future direction and intent are subject to change or withdrawal without notice, and represent goals and objectives only. Information about non-IBM products is obtained from the manufacturers of those products or their published announcements. IBM has not tested those products and cannot confirm the performance, compatibility, or any other claims related to non-IBM products. Questions on the capabilities of non-IBM products should be addressed to the suppliers of those products. Prices subject to change without notice. Contact your IBM representative or Business Partner for the most current pricing in your geography. 34 © 2012 IBM Corporation