Falcon Invoice Discounting: Empowering Your Business Growth
Marketing Graphics Designer
1.
2.
3. S-223 P5000 Packer
Penetrator Procedure
Prepared for
ENCANA - Weatherford
Qatar
Prepared by
QUICK CONNECTORS INC.
5226 Brittmoore ♦ Houston, Texas 77041
Date prepared
April 7, 2008
4.
5.
6.
7.
8. Quick Connectors Incorporated (QCI) is a leading provider of wellhead and
QCI - About Us
Packer Penetrator Systems
Manifold Bushing Examples
packer penetrator systems for use with electrical submersible pumps (ESP). QCI is proud of
delivering quality, on-time products that meet our customers' requirements. We have over 20 years of
oil field experience installing our systems worldwide with a track record of excellence and reliability.
QCI electrical penetrator systems eliminate the need for cable splicing, saving hours of costly rig time,
and increasing reliability by reducing exposure to reactive agents.
QCI offers various types of wellhead penetrator systems designed to work with a variety of
Standard 3-Hole applications to meet customer requirements and needs. QCI wellhead penetrator systems can be
designed to fit new or existing wellheads (concentric or non-concentric applications), or to
accommodate wellhead applications that were not originally designed for use with ESP applications.
QCI wellhead penetrators can be easily retrofitted to replace existing competitor type mandrel
penetrator systems.
QCI also offers specialty penetrator systems for applications requiring the use of BOP Cans, ESP
Packers, dual or triple completions, and heater applications. These applications can also be retrofitted
Multiple Ports for to replace existing competitor systems.
Additional Control Lines
All of the QCI penetrator systems are suitable for 375°F/ 190°C, and can be fitted to all ESP pump
cables and electrical requirements currently in use (up to 5000 Volts and 250Amps).
QCI operates under the ISO 9001-2000 requirements. All of the QCI wellhead penetrator
systems are third party approved by Factory Mutual (FM) and CSA. The QCI products are designed to
meet the highest classifications for safety compliance within the United States for operation of
electrical equipment in hazardous/explosive locations (Class I, Divisions 1 & 2).
We pride ourselves on quick delivery and excellent engineering support. QCI provides on-site
installation (domestic and international) and can provide technical support through highly trained
international representatives. Complete in-house training simulating wellhead and packer penetrator
installation can be provided for customers who wish to install QCI equipment. Training videos and
installation procedures are available upon request.
QCI – Unique, Adaptable, Global
Multiple Port Type Dual String Type
Packer Packer
1 Lower Pump Cable 5 Manifold Bushing
2 Triskelion Lower 6 Male & Female Connectors
3 Male & Female Connectors 7 Triskelion Upper
4 Seal Fittings 8 Upper Pump Cable
Features/Specifications
? No splices above and below the packer.
? A mainfold bushing is provided for dual string packers, and
can accommodate extra ports for control lines, if necessary.
? For small diameter and multiple port packers, the
penetrators pass through 3 individual ports through the
packer.
? Voltage: 5000 VAC, 3 Phase
? Amperage: 150 Amp and 257 Amp versions available
8 Multiple Port Dual String ? Pressure: 5,000 psi API WP (10,000 psi Proof Test)
1
1
Type Packer Type Packer ? Temp: 375° F, 190° C
9. P3000-2
P5000-Dual ESP
Triskelion 3” Union
P3000-2 Mini Mandrel Surface Power Cable (CLX) Male & Female Connectors Surface Conduit System
P3000-2 Canned Pump Coupling (CPC) Cable Gland Bottom Seal Fitting Detonation Arrestor
Top Seal Fitting Cable Gland
Wellhead Penetrator System Surface Conduit System P5000 Dual ESP Flexible Fitting Surface Power Cable (CLX)
Breather Vent/Detonation
“Boll Weevil Type” Arrestor Wellhead Penetrator System Bracket Assembly
Features/Benefits Specifications Features/Benefits Specifications
? Eliminates cable splices in the wellbore. ? FM & CSA Approved ? Adaptable with either concentric or eccentric ? FM & CSA Approved
wellhead completions, and can be run in small
? Available as a P3000-2F for flat cable. ? Voltage: Dependant on Max. Rating of ESP Cable annular space wells.
? Voltage: 5000 VAC, 3 Phase
? Cable is stripped, and three pump cable wires are ? Amperage: Dependant on Max. Rating of ESP Cable ? Eliminates cable splices in the wellbore. Three ? Amperage: 150 Amp and 257 Amp versions available
separated and sealed off with an EPDM sealing element
and mini mandrel insert. Pump cable (flat or round) is
? Pressure: 3,000 psi API WP (6,000 psi Proof Test) plug-in connections are all that are required below ? Pressure: 5,000 psi API WP (10,000 psi Proof Test)
the hanger.
run continuously through the wellhead. ? Temp: 375° F, 190° C ? Temp: 375° F, 190° C
? Reusable surface conduit system suitable for hazardous ? Hazardous Area: Class I, Divisions 1 & 2 Group D ? Three flexible fittings with Swagelok connections ? Hazardous Area: Class I, Divisions 1 & 2 Group D
seal off the penetrator above and below the tubing
locations.
hanger.
? Designed to eliminate large mandrel type penetrators. ? Permits the use of shielded and non-shielded
? UL listed surface cable (CLX) is terminated and sealed cables.
in the conduit system for required length to reach the
motor control panel.
? Reusable surface conduit system suitable for
hazardous locations.
? Permits the use of shielded and non-shielded cables. ? UL listed surface cable (CLX) is terminated and
sealed in the conduit system for required length to
reach the motor control panel.
2 7
10. 3/4” NPT
PT
P3000-2DM
3/4” NPT
/4” PT
3/4 NPT
4”
► Eliminates cable splices in the wellbore.
► Available as a P3000-2FDM for flat cable.
1/4” NPT
► ESP cable is stripped and the three cable wires
are separated and sealed off with an elastomer
sealing element.
► A QCI dummy mandrel is provided to fit the
existing wellhead, replacing the competitor’s
mandrel.
► Reusable surface conduit system suitable for
hazardous locations.
► UL listed surface cable (CLX) is terminated
and sealed in the conduit system for required
length to reach the power supply.
► Permits the use of shielded and non-shielded
cable.
11. 4
3
Specifications
6
5
2
7
1
P3000-2 “Boll Weevil” Type
P3000-2DM
● FM & CSA Approved 1 P3000-2 Mini Mandrel
P3000-2 Mini Mandrel
● Voltage: Dependant on Max. Rating of ESP Cable 2 CPC Elbow Assembly (CPC)
Canned Pump Coupling
● Amperage: Dependant on Max. Rating of ESP Cable 3 Surface Junction box
Surface Conduit System
● Pressure: 3,000 psi API WP (6,000 psi Proof Test) 4 Breather Vent
Breather Vent/Detonation Arrestor
T
● Temp: 375° F, 190° C 5 Cable Terminator Fitting
Cable Gland
H
● Hazardous Area: Class I, Divisions 1 & 2 Group D 6 Surface Power Cable (CLX)
Surface Power Cable
12.
13.
14. S-223 P5000
Packer Penetrator
Installation Procedure
Prepared for
Tarpon Operating
WC 661 A2
Prepared by
QUICK CONNECTORS INC.
5226 Brittmoore ♦ Houston, Texas 77041
Date prepared
February 19, 2008
15.
16. S-111 P5000 Packer
Penetrator Installation
Prepared for
ONGC India
Schlumberger
Prepared by
QUICK CONNECTORS INC.
5226 Brittmoore ♦ Houston, Texas 77041
Date prepared
June 19, 2008
17. S-222 P5000 Model 1
Wellhead Penetrator
Installation
Prepared for
Tarpon Operating
WC 661 A2
Prepared by
QUICK CONNECTORS INC.
5226 Brittmoore ♦ Houston, Texas 77041
Date prepared
January 11, 2008
18. S-219 P5000 Wellhead Heater Cable
Installation Procedure
Prepared ffor
Prepared or
Pemex - Tyco
Pemex - Tyco
Angosttura 21
Angos ura 21
Prepared by
Prepared by
QUICK CONNECTORS INC.
5226 Brriittttmoorre ♦ Houstton,, Texas 77041
5226 B moo e ♦ Hous on Texas 77041
Datte prreparred
Da e p epa ed
Marrch 28,, 2008
Ma ch 28 2008