Independent Call Girls In Jaipur { 8445551418 } ✔ ANIKA MEHTA ✔ Get High Prof...
Tongue drive system
1. TONGUE DRIVE SYSTEM
Presented by:
Anagha Balakrishnan
ER & DCI-IT,Vellayambalam
RollNo: 07
2. What is TDS?
TONGUE–OPERATED assistive technology for
people with severe disability to control
their environment
DEVELPOED by GT Bionics Lab
3. Assistive Technology ?
ASSISTIVE TECHNOLOGY is an umbrella term that
includes assistive, adaptive, and rehabilitative devices
for people with disabilities and also includes the
process used in selecting, locating, and using
them.
4. Why Spinal Cord Injury is Fatal?
•SPINAL CORD is located inside the spine
•CONNECTS the brain to nerves in the
body
•MESSAGE travel in very high speed from
brain to rest of the body
5. Cause of Spinal Cord Injury…
SPINAL CORD
PARALYSIS is squashed or blood circulation of
the spinal cord is cut off, which will result in..
UNABLE to easy breath
UNABLE to feel pain or sensation
SORES on skin not being able to move around
SEXUAL dysfunction
6. Existing Assistive Technologies…
Sip-and-Puff wheel chair
•USE air pressure to control
wheel chair by sipping and
puffing
•NOT good for people with
week breathing
7. Voice activated powered wheelchair
•WHEN user speaks
commands, a microphone in a
throat detects the vibration of
vocal cord
•UNSTABLE for powered
wheelchair control in noisy
8. Head control
•WHEELCHAIR controlled by
head control device
•NOT good for the
users with bad head movement
ability
10. TONGUE and mouth occupies the major part
MUSCLE fibers in tongue is similar to heart muscle fibers
LOW rate of Perceived Exertion
DIRECTLY connected to the brain
HIDDEN inside mouth will give a certain degree of privacy
12. TDS –Overview…
SMALL permanent magnet pierced on the tongue
ARRAY of Hall-effect magnetic sensors senses
the magnetic field
SENSORS mounted on a dental retainer and
attached on the outside of the teeth
SMALL batteries are intended to power
13. POWER management circuitry scans through the
sensors and turn on one at a time
TDM analog output are digitized, modulated and
transmitted to the external control unit through a
wireless link
FROM their signals are demodulated, demultiplexed to
extract individual sensor output
BY processing these output command is identified
15. BUILD on a face shield
FUNCTION is to directly emulate mouse pointing and
selection function with the tongue movement
SIX COMMANDS : up, down, right, left, single click &
double click
SSP algorithm running in background
16. MAGNETIC TRACER : small, cylindrical, rare-earth
permanent magnet
PAIR of two-axis magnetic field sensor modules- each
contained a pair of orthogonal magneto-inductive sensor
THREE AXIS MODULE: used as a reference electronic
compass to minimize the effect of external magnetic field
interference
17. CONTROL unit & reference compass hidden under face
shield cap
ENTIRE system was powered by a 3.3V coin-sized
battery(CR2023)
18.
19. SENSOR output where send serially to the ultralow-
power MSP430 microcontroller
MICROCONTROLLER took 11 samples from each sensor
SAMPLES are arranged in a data frame and wirelessly
transmitted to a PC across a 2.4 GHz wireless link
established between nRF2401 transceivers
20. Sensor Signal Processing algorithm
DEVELOPED in MATLAB environments
2 phases: Training & Testing
•TRAINING : USES principal components analysis
(PCA) to extract the most important features of the
sensor output waveforms for each specific command
• USER repeats each of the six designated
commands 10 times in 3-second intervals
21. • TOTAL of 12 samples (3 per sensor)
are recorded in 12-variable vectors
• THE PCA-based feature-extraction
algorithm calculates the eigenvectors and Eigen values
based on the 12-variable vectors
• THREE eigenvectors with the largest
Eigen values are then chosen to set up the feature
matrix [v1, v2, v3]
22. • BY multiplying the training vectors
with the feature matrix, the SSP algorithm forms a
cluster (class) of 10 data points from training for each
specific command
•TESTING: k-nearest neighbour (kNN) classifier is then
used in real time to evaluate the proximity of the
incoming data points to the clusters formed earlier in
the training phase
23. • kNN starts at the incoming new data point
and inflates an imaginary sphere around that data point
until it contains a certain number (k) of the nearest
training data points
• IT associates the new data point to the
command that has the majority of the training data
points inside that spherical region.
24. AFTER finding the intended user command,
the mouse pointer starts moving slowly in the selected
direction
FOR faster access the user can hold his or
her tongue in the position of the issued command and
the pointer will gradually accelerate until it reaches a
certain maximum velocity
25. Training Session
GRAPHICAL user interface (GUI) prompted the user to
define each command by moving his tongue from its
resting position to the corresponding command position
when the command light was on and returning it back to
the resting position when the light went off
26. THIS procedure was repeated 10 times for the entire set of
six commands plus the tongue resting position, resulting
in a total of 70 training data points.
30. Block diagram & hardware component
SYSTEM consists of the hall effect sensors (A1231),
MSP430 microcontroller, H-Bridge driver (SN754410)
31. 4 ADC channels of MSP430 convert analog signals from
sensors to digital for processing
BASED on the processed information microcontroller
drives the driver IC
DRIVER IC drives the DC powered wheelchair
32. SENSOR- Linear Bipolar Hall effect sensor
TRANSDUCER which varies its output voltage in
response to changes in magnetic field
•VOLTAGE:4.5V-5.5V
•OUTPUT is an analog
voltage that vary from 0-5V
•THAT is converted to a
digital value by ADC
33. H-BRIDGE DRIVER : used to drive the wheelchair
SN7454410:BidirectionalH-Bridge driver
5V power supply is given
SPEED of the wheelchair is controlled by the PWM signals
from MSP430
34. •4 SWITCHES
•WHEN A and D are closed, a
positive voltage applied across the
motor
•WHEN B and C are closed , voltage
is reversed, allowing reverse operation
of the motor
35. DC Motors and Gear Box
•5V DC motors with a gearbox for driving
the vehicle
•USED 2 motors: Left and right
•LEFT motor at rest and right in motion
turn vehicle left and vice versa
•FOR forward and backward motion both
the motors are driven in same direction
with same speed
36. Software Components
ADC10(Analog to Digital converter)
•MSP430G2252 has 8 ADC channels of 10 bit each
•ADC10 convert the analog signal from the sensor into digital
value
•WE get the value ranging from 0-1023
37.
38. Pulse Width Modulation
•MODULATING technique which generates variable width
pulses is used to vary the speed of the motor
39. Algorithm
•ROUND ROBIN algorithm that implements polling technique
•SENSOR values are always read one after other in a continuous
loop
•FEW threshold values set for each sensor
•IF reading from sensors reaches the threshold value program
triggers the change of state
40.
41. S1 & S2 front sensor , S3 & S4 back sensors
WHITE circle in the middle- resting position of tongue
DIFFERENT flag values for each sensor
IF sensor is high, then the flag value remains high until