ANALYSIS AND DESIGN OF ROBUST CASCADED PV SYSTEM
Ahmed A. A. Hafez
Electrical Engineering Department, Faculty of Engineering, Assiut University, Assiut,
Egypt, PO 71516
ABSTRACT
This paper proposes multi-level cascaded DC/DC system for Photovoltaic (PV) application.
Three PV generators each coupled to a half-bridge buck cell. Each PV-generator-buck-converter
channel is controlled such that maximum power is capture independently under different irradiation
and temperature levels. The system operation under normal and abnormal conditions was
comprehensively investigated. Simple and robust remedial strategies were proposed to mitigate
different anticipated faults. Comprehensive simulation results in Matlab environment were illustrated
for corroborating the performance of the advised cascaded DC/DC system under normal/abnormal
conditions.
Keywords: Multi-level DC/DC, Half-bridge Buck Converter, Internal Mode Control, Faulty
Operation, Remedial Strategies.
I. INTRODUCTION
Energy independence and environmental compatibility are two salient features of PV
systems. The fuel is free, and no noise or pollution is created from operating PV systems [1-3]. Thus,
PV systems are considered to be from the future trendsetters for securing eco-friendly, sustainable
and albeit inexpensive electricity.
The basic solar cell usually operates at less than 1 V. Therefore, these cells are arranged in
series-parallel configuration (PV module) to increase the output voltage, current and power [1-2].
For high voltage/power levels, the PV modules are arranged in series arrangement (PV panel) to
ensure high operating efficiency. However, such arrangements have many disadvantages such as [4]:
a mismatch between the characteristics of the modules in the same panel always exists due to
modules different orientations and/or manufacturing processes. These modules, however, are
restricted to conduct the same current, which limits the panel efficiency to that of the least efficient
module/cell. Moreover, the generated current/power drops significantly, when a single cell/module is
INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING &
TECHNOLOGY (IJEET)
ISSN 0976 – 6545(Print)
ISSN 0976 – 6553(Online)
Volume 4, Issue 5, September – October (2013), pp. 20-35
© IAEME: www.iaeme.com/ijeet.asp
Journal Impact Factor (2013): 5.5028 (Calculated by GISI)
www.jifactor.com
IJEET
© I A E M E
International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print),
ISSN 0976 – 6553(Online) Volume 4, Issue 5, September – October (2013), © IAEME
21
partial/fully shaded. To limit the power loss, a bypassing diode around the shaded module has to be
utilized. However, the power from the shaded module is lost under these circumstances [5-7].
A proposed solution [4-11] is to place a separate DC/DC chopper across each PV module.
The outputs of the choppers are series connected to obtain high DC voltage level. This allows the
system to be transformer free, which boosts the efficiency and reduces cost, volume and weight.
Furthermore, attaching a separate DC/DC chopper to each module has the advantage of decoupling
the modules. This allows the maximum power point of each module to be tracked independently.
Moreover, a shaded module has no impact on the remaining modules, as it could be bypassed
through the corresponding DC/DC converter. Furthermore, a fault within PV module/converter
disables only the faulted module-converter, while the system can continue functioning albeit at
reduced capacity.
A little was reported about cascaded DC-DC choppers particularly for PV applications [4-7].
A simple and efficient maximum power point tracker is introduced in [4]. This MPPT is claimed to
allow the DC-DC converters to be serially connected in the output side and operate correctly without
any additional requirements, however, no detailed analysis is reported in [4] of such series
connection.
Buck, boost, buck-boost and cuk C-DC converter topologies were compared regarding
steady-state efficiency in [8] for the cascaded operation. The buck-boost and cuk topologies suffer
from poor switch utilization achieving maximum of 25% at a duty cycle of 50%. Moreover, the
buck-boost topology has discontinuous input/output currents, and the cuk topology has extra energy
storage components. Ref. [8] concluded that buck and boost topologies should be subjected to further
comparison to identify the optimal topology. However, [8] introduces neither control techniques nor
dynamic performance.
In a cascaded PV system, the DC/DC converter forces the corresponding PV generator to
operate at Maximum Power Point (MPP) under varying conditions. Various MPP tracking
techniques were reported in literature [12-15]. The incremental conductance is a wide adopted MPP
tracker, due to its ability of tracking MPP at wide range of irradiation and temperature levels [12-15].
In this paper, a multi-level cascaded DC/DC converter system for PV application is proposed.
An innovative implementation of incremental conductance MPPT is also proposed. This modified
MPPT allows almost instantaneous tracking for MPP of each PV generator irrespective to
climatologically conditions and/or other PV generators. Therefore, each module PV generator-
DC/DC converter is decoupled from the remaining to achieve fault-tolerant system. The proposed
compensator is tuned using Internal Mode Control (IMC). The paper introduces also a detailed
analysis for the system operation under steady-state and transient conditions. Moreover, the system
performance under different types of faults is thoroughly examined.
II. TOPLOGY OF DC/DC CONVERTER
The boost and buck are most promising topologies for cascaded system. The boost
characteristics allow the use of minimum number of PV modules to obtain a high DC voltage level.
Moreover, the input inductor reduces the ripples in currents of the PV generators. However, the boost
topology in PV cascaded system has a serious problem. The series connection forces equal output
currents, and in the boost cell Iin > Iout is an operational constraint. Therefore, if a PV generator is
shaded, its current drops significantly and hence the power of the entire system. Thus, the boost
topology is inappropriate for series connection. However, it may work satisfactory in the parallel
cascaded systems. In the parallel operation of boost-based cascaded system, the system output
current is a summation for the output currents of the parallel modules. Thus, if a PV generator
encounters shading, its current drops and hence the output current of this faulty module. The
International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print),
ISSN 0976 – 6553(Online) Volume 4, Issue 5, September – October (2013), © IAEME
22
remaining modules are still functioning normally, and the system output power/current is albeit
reduced, Fig. 1.
Fig. 1. Multi-level cascaded DC/DC boost converters attached to PV generators, faulty PV generator
(grey), series connected (left), parallel connected (right)
The buck topology can track the MPP at wide climatological conditions. Moreover, in the
buck based cascaded system, each channel, PV generator coupled to a buck converter, is entirely
decoupled from the remaining channels. Furthermore, in the buck topologies, the semiconductors
arrangement ensures continuous system operation under fault disabling a PV generator. As the
freewheeling diode provide alternative path for the current under PV generator failure. This scenario
is shown in Fig. 2.
Fig. 2. Multi-level cascaded DC/DC buck converters attached to PV generators, faulty PV generator
(grey)
III. SYSTEM ARCHITECTURE
The system under concern, Fig, 3, is composed of three PV generators, each coupled to a
half-bridge buck converter. The unit composed of a PV generator, buck converter and the associated
controller is defined here as a channel.
The half-bridge is used in the system under concern due to its availability, modularity and
ease of packaging. Moreover, the half-bridge allows the deployment of a modulation strategy, which
reduces the generated harmonics and filter size without comprising the efficiency. The half-bridge
buck cell has also bidirectional power flow capability, which could be utilized in interfacing different
types of energy storage devices into the DC bus. These energy storage elements are usually deployed
in cascaded system to optimize system performance and ensure interruptible system operation.
The half-bridges are in series in the output side. An independent controller for each bridge is
used. The controller forces the PV generator to operate at their MPP independently. Moreover, it
maintains the decoupling between the PV generators and the buck converters.
International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print),
ISSN 0976 – 6553(Online) Volume 4, Issue 5, September – October (2013), © IAEME
23
1
Vpv
2
Vpv
o1
V
o2
V
V
out
1
L
2
L
3
Vpv o3
V
3
L
t1
I
t2
I
t3
I
o1
I
o2
I
o3
I
1
G
1
T
2
G
2
T
2
G
2
T
Fig. 3. Multi-level Cascaded DC/DC half-bridge converters attached to PV generators
A. PV Generator
Different models are proposed for stimulating PV cell, these models vary in accuracy and
complexity. Moderate model is proposed here, the PV cell is modeled as a solar irradiation and
temperature dependent current source Iph in parallel with diode. This combination is in series with a
series resistance Rs [8]. This model of the PV cell has the advantages of accuracy, robustness and
simplicity.
Basically the PV cells are grouped in series to deliver a reasonable voltage/power, these
structures as mentioned before are themed modules. The module has an equivalent circuit similar to
that of the cell.
s
R
ph
I
t
I
t
V
Fig. 4. Equivalent circuit of PV cell/module
The relation between the terminal current It and voltage Vt of a PV module is expressed by,
t s
th
t ph o
V +IR
V
I =I -I e -1
 
 
 
 
 
(1)
where Io, Iph, I and V are saturation current, photo current, current and voltage of the module
respectively. Vth =nNskT/q is thermal voltage of the module; n, Ns , K, T and q are ideality factor,
number of cells in series, Boltz’s man constant and electron charge respectively. The PV modules
under concern are from Kyocera KC200GT type. The parameters of KC200GT module are given in
Table 1 [16].
International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print),
ISSN 0976 – 6553(Online) Volume 4, Issue 5, September – October (2013), © IAEME
24
TABLE I
PARAMETERS OF KC200GT SOLAR MODULE AT 25O
C AND 1000W2
M-2
[16]
No. of cells 54
Short circuit current 8.21A
Open circuit voltage 32.9V
Current at MPP 7.61A
Voltage at MPP 26.3V
Maximum power 200.143W
Voltage coefficient -0.1230V/K
Current coefficient 0.0032A/K
The value and series resistance Rs calculated by iterative method in [8] is 0.221 . The PV
modules are grouped in series-parallel arrangement to form array, which is termed here as PV
generator. Each PV generator is consisting of 30 Kyocera KC200GT modules. The relation between
the PV array/generator terminal voltage Vpv and current Ipv could be expressed by a relation similarly
to (1), however it more meaningful to express the PV array/generator current in terms of the voltage,
short-circuit current Isc and open-circuit voltage Voc of the module, as these data are commonly
supplied by the manufacturers at standard conditions. Thus the terminal current Ipv is given in terms
of terminal voltage Vpv, short-circuit current Isc and open-circuit voltage Voc by,
ss pv s
pv ss oc
ss
pv ss sc
ss th
N I R
V -N V +
M
)
N V
I =M I 1-exp(
 
 
 
  
 
(2)
where Mss and Nss are number of shunt and series connected modules respectively. The
current Ipv and the voltage Vpv of the PV array/generator under concern calculated at 25o
C and
different radiation levels are given in Fig. 5.
0 100 200 300 400 500 600 700
0
2
4
6
8
10
12
14
16
18
20
Voltage (V)
Power(kW),current(A)
I-V 1kW
2
m
-2
P-V 1kW
2
m
-2
I-V 0.75kW
2
m
-2
P-V 0.75kW
2
m
-2
I-V 0.5kW
2
m
-2
P-V 0.5kW
2
m
-2
I-V 0.25kW
2
m
-2
P-V 0.25kW
2
m
-2
I-V for maximum power
P-V for maximum
power
Fig. 5. Current and power of a PV generator against terminal voltage for 25o
C temperature and
different levels of solar irradiance, locus of maximum power (black)
Figs. 5 reveals that the voltage at maximum power is less dependent on the solar irradiation [13].
Moreover, the generator current/power varies almost linearly with the insolation.
International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print),
ISSN 0976 – 6553(Online) Volume 4, Issue 5, September – October (2013), © IAEME
25
In the series-connected system, Fig. 3, the steady-state output currents are equal o1
I = o2
I = o3
I .
Assuming lossless system, the output voltage of each bridge oi
V depends on the DC-link voltage VDC
and the ratio of cell power to that of the entire system as given in (3),
*
DC ini
oi
ini
i=1
P
P
V
V = m
∑ (3)
where m is number of the series converter/channels. Equation (3) indicates that for series-
connected system, Fig. 2, when the PV generators have the same solar irradiance levels, the output
powers are nearly equal, and thus the output voltages of the correspondences buck bridges. However,
as a PV generator is partially/fully shaded, the output voltages of bridges are affected. The shaded
module experiences reduction in the output voltage, while the unshaded modules undergo over
voltage. Moreover, although the unshaded PV generators still deliver the same power, the system
output current will be reduced.
B. Half-bridge Converter
In the system under concern, a separate inductor filter is attached to each half-bridge
converter, Fig. 3. These inductors can be lamped into a single inductor allocated in output side
without affecting either dynamic or static performances. However, the distributed inductor topology
has the advantages of modularity, ease of upgrading and cost-effectiveness. Since the system can be
expanded/contracted by adding/removing a half-bridge with its associate filter inductor.
Employing shift switching modulation strategy in the proposed system reduces the current
ripple and inductor size, while maintaining high efficiency. As the switching frequency is kept
constant at fs, meanwhile the harmonics in the inductor voltage are shifted to m*fs. In the shift
switching technique, the carrier waveforms are delayed by 2π/m from each another.
The total output inductance could be calculated by,
( )( )V V 1 D Dmax max maxmin
L=mL =i
mf Is o
− −
∆
(4)
where Io is ripple in the output current; Dmax is equivalent duty cycle, where maximum
ripple occurs, and it is equal to 0.5. Vmax and Vmin are defined by,
1 1
V =V D-Dmod +max pvi
m m
 
 
 
(5)
1
V =V D-Dmodmin pvi
m
 
 
 
(6)
where D is the operating duty cycle and mod is the modulus function. The total inductance L
computed for 5% ripple in the output current at 1000w/m2
solar irradiance and 25o
C temperature is
0.9mH.
International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print),
ISSN 0976 – 6553(Online) Volume 4, Issue 5, September – October (2013), © IAEME
26
C. MPPT
The slope of power-voltage curve of a PV generator could be expressed by,
pv pv
pv pv
pv pv
V
dV dV
dP dI
=I +
, (7)
The slope of power-voltage curve of a PV module, Fig. 5, is positive on the left of MPP,
negative on the right and zero at MPP. Thus the relation between the incremental and instantaneous
conductance is given by,
pv pv
pv pv
pv pv
pv pv
pv pv
pv pv
, left MPP
V V
, at MPP
V V
, right MPP
V V
I I
-
I I
=-
I I
-
∆
∆
∆
∆
∆
∆
f
p
, (8)
MPP is tracked by continuously comparing the incremental and instantaneous conductance
and incrementing/decrementing the PV voltage/current until MPP is reached. This technique is
reported in the literature under Incremental Conductance Controller (ICC) [13-15].
An innovative implementation for ICC is proposed here under the theme of Modified Incremental
Conduction Controller (MICC). According to (7), the sum of the incremental and instantaneous
conductance is equal to zero at MPP; therefore employing a sufficiently fast PI controller ensures
that sum is settled at zero.
pv pv
pv pvV V
I I
E = +
∆
∆
, (9)
D. Tuning of the controller
Each channel, PV generator coupled to buck converter, is controlled individually, thus the
cascaded system is modeled for control purpose as single PV generator converter channel as shown
in Fig. 6.
pv
V
pv
I
Vo
Io
Ls
L
R
Fig. 6. Schematic of single channel and control circuit
To simplify the controller design, the cascaded system is assumed to be loaded by a pure
resistive load. The sum of incremental and instantaneous conductance is compared with zero, to
force system operation at MPP; then the error is supplied to Proportional Integral (PI) controller. The
output signal of the PI compensator is used to generate the switching signal.
International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print),
ISSN 0976 – 6553(Online) Volume 4, Issue 5, September – October (2013), © IAEME
27
The top and bottom switches operate in complementary fashion; for example, when the top
switch is on the bottom one is off and vice versa. Thus, when the top switch is on, the system in Fig.
6 could be expressed mathematically by,
s o
pv o
L
L dv
V = +v
R dt
(10)
During the top switch off state, the system is expressed by,
s o
o
L
L dv
0= +v
R dt
(11)
Averaging (10) and (11) over a switching cycle,
s o
pv o
L
L dv
V D= +v
R dt
(12)
where d is duty cycle. The voltage of PV generator at MPP is assumed constant, thus the
system could be considered as single pole system as,
( )
( ) pvo
s
s L
Vv s
=G s =
D(s) 1+sL /R
(13)
A PI controller is tuned using IMC technique. The IMC is extracted from the internal mode
principle that states the control can be achieved if the control system encapsulates, either implicitly
or explicitly, some representation of the process to be controlled. A thoroughly discussion for the
IMC are given in refs. [17,18]. In this work, the design of the controller is only addressed.
Assuming that the model of the process, controlled system, ( )PG s has the same transfer function
as the process itself, ( )sG s .
( ) ( ) pv
P s
s L
V
G s =G s =
1+sL /R
(14)
Separating the model of the process into invertible ( )+
P
G s and non-invertible
( )-
P
G s components respectively, the controller of the IMC is given by
( ) ( )
( )
+
-1 s L
IMC p k
pv f
1+sL /R
C s =G s =
V 1+t s
(15)
where tf and k are the parameter and the order of the filter. The parameter and the order of the
filter are chosen such that the bandwidth of this controller is high enough to provide acceptable
tracking for any abrupt change in solar irradiation/temperature. In meanwhile, the controller has the
ability to provide adequate attenuation for switching ripples in the PV generator voltage and current.
The merits of the IMC technique are [17,18] :
1. simplicity,
2. cost-effectiveness,
3. time-delay compensation,
4. offset free response and
5. good tracking for the setpoint and disturbance rejection.
International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print),
ISSN 0976 – 6553(Online) Volume 4, Issue 5, September – October (2013), © IAEME
28
The frequency response of closed loop transfer function Vo/ Erref is shown in Fig. 7.
-35
-30
-25
-20
-15
-10
-5
0
Magnitudeof∆∆∆∆Vo
/∆∆∆∆Erref
(dB)
10
0
10
1
10
2
10
3
10
4
10
5
10
6
10
7
10
8
-90
-45
0
Phaseo(deg)∆∆∆∆Vo
/∆∆∆∆Erref
(degree)
Frequency (rad/sec)
Fig. 7. Closed loop frequency response of the Vo / Erref with IMC controller
The IMC controller introduces adequate bandwidth of around 1.5x106
rad/sec Fig. 7, which
might result in adequate tracking for the solar irradiance variations. Moreover, the system behaves as
low pass filter particularly for switching harmonics, Fig.7.
An equivalent classical PI feedback controller CPI(s) of the IMC controller CIMC(s) could be
obtained from,
( )
( ) ( )
IMC
PI
IMC p
C s
C (s)=
1 C s G s−
(16)
The parameters of the PI controller, CPI(s) are given in Table2.
TABLE 2
PARAMETERS OF THE PI CONTROLLER
Proportional gain Kp 5
Integral gain Ki 200
IV. STATIC PERFORMANCE
The static performance of the proposed system is estimated by computing the efficiency at
different solar irradiance levels. The following assumptions are considered:
• The losses in the input and output capacitors are ignored.
• The different channels share the load equally, thus the efficiency is calculated per channel.
• The input and out filters suppress the ripples in the input and output currents
The efficiency of a channel is given by,
International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print),
ISSN 0976 – 6553(Online) Volume 4, Issue 5, September – October (2013), © IAEME
29
ini pv_cu c_cond c_swit ind_cu
ini
P -P -P -P -P
ξ=
P
(17)
where Pini , Ppv_cu, Pind_cu, Pc_cond and Pc_swit are a channel input power, the copper losses in a PV
generator and the output inductors, conduction and switching losses in a converter channel
respectively
The switch and the power diode in the converter channel were modeled during the on-state as
a constant voltage element; thus the converter steady-state average conduction losses is given by,
c_cond ce(sat) avg_Q on avg_DP =V I +V I (18)
where Vce(sat), Iavg_Q, Von , and Iavg_Q are the on-state switch voltage drop, average switch
current, diode on-state voltage drop and diode average current respectively.
The switching frequency was determined as a compromise between the inductor size and
switching losses; a value of 10 kHz was chosen. The switching losses of a switch in the three
converter topologies are determined from switching frequency fs, turn on eon, and turn off eoff
energies. The turn on eon and turn off eoff energy curves of the proposed switches could be considered
to vary linearly with the switch current, thus the switch steady-state average switching losses can be
approximated by,
( )c_swit s on off avg_QP =f E +E I (19)
where Eon and Eoff are on-state constant and off-state constant respectively. Substitute (18) and (19)
into (17) and simplify the efficiency is given by,
( )pv
pv s ce(sat) on L s on off2
pv
I1
I - - ( -1)- -
D Dξ=1-
V
R V V R f E +E
(20)
Equation (20) indicates that the efficiency depends on the operating strategy of the converter
channel. The converter drives the associated PV generator at MPP by modifying the duty cycle
according to solar irradiance and temperature levels. The efficiency of the proposed cascaded PV
system at different solar irradiation is illustrated in Fig. 8
0 100 200 300 400 500 600 700 800 900 1000
0.82
0.84
0.86
0.88
0.9
0.92
0.94
0.96
0.98
1
Solar irradiance Wm
-2
Efficiency
Fig. 8 Efficiency of cascaded PV system at different solar irradiation levels
International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print),
ISSN 0976 – 6553(Online) Volume 4, Issue 5, September – October (2013), © IAEME
30
Fig. 8 shows that the efficiency of the proposed system increases with the solar irradiance.
The system efficiency drops significantly below 100W/m2
insolation level. The graph illustrated in
Fig. 8 shows the efficiency of the proposed system only when all modules are subjected to the same
solar irradiance level. The efficiency of the proposed system is anticipated to be likely albeit lower
than Fig. 8, due to the ignored losses.
IV. DYAMIC RESPONSE
In the following, the system performance for different irradiation levels is investigated. The
convergence speed of MPPT and the effectiveness of the decoupling between the different channels
are assessed by forcing step change in the solar irradiance in Figs. 9 and 10. This is realized by
stepping the solar irradiance of generator 1 from 1000W/m2
to 100W/m2
at 0.1sec, 100W/m2
to
600W/m2
at 0.2sec, and 600W/m2
to 1000W/m2
at 0.3sec; the solar irradiance of generator 2 is
stepped from 1000W/m2
to 500W/m2
at 0.1sec and from 500W/m2
to 1000W/m2
at 0.3sec. Generator
3 operates at 1000W/m2
over the time span under concern.
0.02 0.06 0.1 0.14 0.18 0.22 0.26 0.3 0.34 0.38
0
4
8
12
16
20
Time (sec)
PVcurrents(A)
0.02 0.06 0.1 0.14 0.18 0.22 0.26 0.3 0.34 0.38
0
2000
4000
6200
Time (sec)
PVpowers(W)
Gen.#1
Gen.#2
Gen.#3
0.02 0.06 0.1 0.14 0.18 0.22 0.26 0.3 0.34 0.38
0
140
280
420
Time(sec)
PVvoltages(V)
Fig. 9. Top graph: voltages of PV generators, Middle graph: currents of PV generators, Bottom
graph: powers of PV generators for 25o
C and solar irradiance of generator 1 (blue) stepped from
1000W/m2
to 100W/m2
at 100msec, 100W/m2
to 600W/m2
at 200msec and from 600W/m2
to
1000W/m2
at 300msec; solar irradiance of generator 2(black) stepped from 1000W/m2
to 500W/m2
at
100msec, and 500W/m2
to 1000W/m2
at 300msec; solar irradiance of for generator 3(red) constant at
1000W/m2
Fig. 9 shows that MICC achieves fast tracking for MPP even under hypothetical conditions,
as abrupt change for solar irradiance. Moreover, the controller achieves full decoupling between
different channels. A channel responds only when its operating conditions change, and there is no
response for conditions affecting other PV generators/buck converters, although they shire the same
DC-link. The figure show also that the output currents/powers of the PV generators vary linearly
with the solar insolation. This was predicted in Fig. 5, where static performance of a PV generator
was computed and drawn. The voltage of the PV generators, is less affected by solar irradiance
change, as shown in ref. [13].
International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print),
ISSN 0976 – 6553(Online) Volume 4, Issue 5, September – October (2013), © IAEME
31
0.02 0.06 0.1 0.14 0.18 0.22 0.26 0.3 0.34 0.38
100
200
300
400
Time (sec)
DC-linkvoltag(V) 0.02 0.06 0.1 0.14 0.18 0.22 0.26 0.3 0.34 0.38
0
10
20
30
40
50
60
70
Time (sec)
Outputcurrent(A)
0.02 0.06 0.1 0.14 0.18 0.22 0.26 0.3 0.34 0.38
0
50
100
150
Time (sec)
Averagevoltagesofoutputchannels
Channel 1
Channel 2
Channel 3
Fig. 10. Top graph: DC-link voltage, Middle graph: output current, Bottom graph average values of
channels’ voltages for channel 1 (blue) solar irradiance stepped from 1000W/m2
to 100W/m2
at
100msec, 100W/m2
to 600W/m2
at 200msec and from 600W/m2
to 1000W/m2
at 300msec; for
channel 2 (black) solar irradiance stepped from 1000W/m2
to 500W/m2
at 100msec, and 500W/m2
to
1000W/m2
at 300msec; for channel 3 (red) solar irradiance constant at 1000W/m2
The output current of the system varies nearly linearly with solar irradiance, Fig. 10. The
switched switching modulation strategy reduces the ripples in the output currents and the DC-link
voltage. Equation (2) predicts that in a cascaded PV system when a generator/channel encounters
shading, its output power/voltage drops and hence the DC-link voltage. The output voltage of the
shaded channel undergoes voltage reduction, while unshaded channels experiences increase in their
output voltages. Fig. 10 validates this conclusion. In this Figure, generators/channels 1 and 2
encounter shading starting from 100msec with different degrees of solar irradiances, while generator
3 is unshaded. Consequently the output voltages of channels 1 and 2 encounter reduction during the
shading while the output voltage of unshaded channel 1 increases.
IV. SYSTEM RESPONSE UNDER ABNORMAL CONDITIONS
The reliability of the system is assessed by examining its performance under abnormal
conditions. In the following, the system behavior under different fault scenarios is investigated. The
faults affected cascaded PV system could in the PV generator and/or the DC-DC converter and the
associated control circuits. The PV generators are subjected to variety of abnormal conditions such
as shading, breakdown, and thermal runaway. Except the shading, the PV generators are less likely
to develop abnormal conditions.
The focus in this work is on the faults in half-bridge. Open and short circuit faults are the
major faults that semiconductors in the half-bridge could develop. These faults could be physically
developed or resulted due to mail function in the gating circuits. The half-bridge has two switches;
each switch composed of a parallel transistor and diode. In the following analysis, the switch is
considered as a unit. Thus the open/short circuit fault disables the whole switch, which is practically
valid.
A. Open-circuit fault
If the top-switch in the converter develops an open circuit fault, the output current circulates
through the freewheeling diode of the bottom switch. Accordingly, the current of the PV generator in
the faulted channel drops to zero.
Fig. 11 shows the system performance under such fault. In this Figure, PV generators 1&3
operate at 1000Wm-2
and 25o
C, while generator 2 runs at 500Wm-2
and 25o
C; whereas, the system
International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print),
ISSN 0976 – 6553(Online) Volume 4, Issue 5, September – October (2013), © IAEME
32
runs under these conditions, switch in buck cell attached to PV generator 2 encounters an open-
circuit fault.
0.1 0.11 0.12 0.13 0.14 0.15 0.16 0.17 0.18 0.19 0.2
0
100
200
300
400
500
Time(sec)
DC-linkvoltage(V)
0.1 0.11 0.12 0.13 0.14 0.15 0.16 0.17 0.18 0.19 0.2
0
30
60
90
Time (sec)
Loadcurrent(A)
0.1 0.11 0.12 0.13 0.14 0.15 0.16 0.17 0.18 0.19 0.2
0
4
8
12
16
20
Time (sec)
PVcurrents(A)
0.1 0.11 0.12 0.13 0.14 0.15 0.16 0.17 0.18 0.19 0.2
0
2000
4000
6200
Time (sec)
PVpowers(W)
Chan./Gen.#1
Chan./Gen.#2
Chan./Gen.#3
Fig. 11. Top graph: DC-link voltage , Middle top graph: load current , Middle bottom graph:
currents of PV generators, and Bottom graph: powers of PV generators for open circuit fault in the
top switch of converter in channel 2 at 150msec, PV generators 1 (blue), 2 (black) and 3 (red) for
1000w/m2
solar irradiance and 25o
C temperature
The current and hence power of PV generator in the faulted channel ceases to zero
immediately after the fault, Fig. 11. The output current and DC-link voltage drop slightly, which is
attributed to the loss of the power of PV generator 2, bottom graph in Fig. 11. This scenario could be
predicted by (2). The voltage of that PV generator in the faulty channel was found to rise to open-
circuit voltage level.
The sustained open-circuited switch has less damaging impact on the cascaded system; as the
losses in PV generator in faulted channel(s) drop to zero. However, the system operates at reduced
output power. Fig. 10 shows that the un-faulted channels still operate at MPP and are not affected by
the fault. This reflects the advantage of the proposed MPPT technique in decoupling the system into
totally independent channels.
If the bottom switch encounters open-circuit, the load current has to circulate through the PV
generator in the faulty channel. This may damage the generator and the top-switch, as the output
current is usually greater than the generator short-circuit current. The remedy strategies for this fault
are limited. The allowed option is to permanently open the top switch and disable the whole system.
This is to protect the faulty channel from damage due to conducting the output current, which is
much higher than the ratings of PV generator and solid-state devices. The open circuited bottom
switch could be identified by monitoring the voltage drop of the top switch. If this voltage drop
exceeds the value corresponding to the system operation at short circuit operating point, the
controller should command the top switch to permanently be opened.
B. Short circuit fault
When a top switch in half-bridge develops short circuit, the captured PV power drops to zero.
The PV generator in the faulted channel operates at short-circuit point, provided that the output
current is greater than the short-circuit current of the PV generator Isc. For this case, the current in the
bottom switch ID is given by,
D o scI =I -I (21)
International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print),
ISSN 0976 – 6553(Online) Volume 4, Issue 5, September – October (2013), © IAEME
33
The system behavior during short circuit fault in top switch in converter attached to PV
generator 2 is shown in Fig. 12. Before the fault the three generators were operating at MPP
corresponding to 1000W/m2
solar irradiance and 25o
C temperature.
0.1 0.11 0.12 0.13 0.14 0.15 0.16 0.17 0.18 0.19 0.2
0
100
200
300
400
500
Time(sec)
DC-linkvoltage(V)
0.1 0.11 0.12 0.13 0.14 0.15 0.16 0.17 0.18 0.19 0.2
0
30
60
90
Time (sec)
Loadcurrent(A)
0.1 0.11 0.12 0.13 0.14 0.15 0.16 0.17 0.18 0.19 0.2
14
16
18
Time (sec)
PVcurrents(A)
0.1 0.11 0.12 0.13 0.14 0.15 0.16 0.17 0.18 0.19 0.2
0
2000
4000
6200
Time (sec)
PVpowers(W)
Chan./Gen.#1
Chan./Gen.#2
Chan./Gen.#3
Fig. 12. Top graph: DC-link voltage , Middle top graph: load current , Middle bottom graph: currents
of PV generators, and Bottom graph: powers of PV generators for short circuit fault in the top switch
of converter in channel 2 at 150msec, PV generators 1 (blue), 2 (black) and 3 (red) for 1000w/m2
solar irradiance and 25o
C temperature
The operation of the PV generator in the faulted channel altered from MPP before the fault to
short-circuit point instantaneously during/post fault, Fig. 12. Although the harvested PV power from
the faulted channel is zero for open and short circuit faults; however, the sustained operation with
short circuit fault stress PV generator more than that of open circuit fault, due to elevated ohmic
losses.
Fig. 12 shows that again the healthy channels in the proposed system still are running at MPP
irrespective to the status of the faulty channel.
The short circuit fault of the bottom switch is similarly to that of the top-switch. In both cases
the captured PV power drops to zero. However for bottom switch short circuit failure, an extra
degree of freedom is existed that the top switch could be permanently opened. This protects the
corresponding PV generator from severe cupper losses, while allowing the cascaded system to
continue functioning albeit at reduced power level.
VI. CONCLUSION
The operation of autonomous cascaded PV system under different operating scenarios was
thoroughly studied; the following conclusions could be drawn:
1. The buck topology is the proper circuit for series operation of PV generators.
2. The boost topology may have a satisfactory performance for parallel connection of PV
generators. However, for series connection of PV generators, the boost topology fails to
maintain the decoupling between the channels under abnormal conditions such as partial
shading.
3. The series connection of PV generators has more advantages than the parallel one such as:
higher efficiency and elimination of second DC/DC conversion
International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print),
ISSN 0976 – 6553(Online) Volume 4, Issue 5, September – October (2013), © IAEME
34
4. The half-bridge buck converter is preferred in cascaded PV system due to its availability and
bi-directional power flow capability, which allows interfacing the batteries/super-capacitors to
the cascaded system.
5. Employing shift switching techniques reduces the ripples in the output/input waveforms
without comprising the efficiency, weight or volumetric dimension.
6. The diode in the buck topology provides adequate freewheeling path for the output current in
case of the corresponding PV generator is partially/fully shaded.
7. Forcing the error between the incremental and instantaneous inductance to be zero, allows
faster tracking for MPP.
8. The IMC controller has the merits of simplicity, time-delay compensation and adequate
tracking for the reference.
9. The short-circuit switch fault encounters excessive copper losses inside the PV generator.
REFERENCES
[1] J. T. Bialasiewicz, "Power-Electronics Systems for the Grid Integration of Renewable Energy
Sources: A Survey" IEEE Transactions on industrial Electronics, Vol. 53, pp. 1002-1016,
August 2006.
[2] J. T. Bialasiewicz, "Renewable Energy System with Photovoltaic Power Generators:
Operation and Modeling," IEEE Transactions on industrial Electronics, Vol. 55, pp. 2752-
2758, July 2008.
[3] E. Endo and K. Kurokawa, "Sizing procedure for photovoltaic systems " in IEEE First World
Conference on Photovoltaic Energy Conversion, 1994, pp. 1196 - 1199.
[4] A. I. Bratcu; I. Munteanu; S. Bacha; D. Picaul and B. Raison" Cascaded DC-DC Converter
Photovoltaic Systems: Power Optimization Issues" IEEE Transactions on Industrial
Electronics,Vol. 19, pp. 120-128, 2010.
[5] M. Valan Rajkumar and P.S. Manoharan “FPGA based multilevel cascaded inverters with
SVPWM algorithm for photovoltaic system” Solar Energy, Vol. 87, pp. 229-245, 2013.
[6] Y. Zhang, J. T. Sun and Y. F. Wang “Hybrid Boost Three-Level DC–DC Converter with
High Voltage Gain for Photovoltaic Generation Systems” IEEE Transactions on Power
Electronics, Vol. 28, issue 8. pp. 3659 – 3664, 2013.
[7] J. Ferreira “The Multilevel Modular DC Converter” IEEE Transactions on Power Electronics,
Vol. 1, issue 99, pp. 1-5, 2013.
[8] R. Geofrey; P. Walker and P. C. Serina, "Cascaded DC-DC Converter Connection of
Photovoltiac Modules," IEEE Transactions on Power Electronics, Vol. 19, pp. 1130-1139,
2004.
[9] W. Chen; X. Ruan; H. Yan and C. K. Tse "DC/DC Conversion Systems Consisting of
Multiple Converter Modules: Stability, Control and Experimental Verifications" IEEE
Transactions on Power Electronics, Vol. 24, pp. 1463-1474, 2005.
[10] D. Montesinos; O. Gomis; A. Sudria and A. Rufer" Multilevel DC/DC converter design for
mobile applications" PCIM 2010, pp. 899-903, 4-6 May 2010.
[11] D. Montesinos; O. Gomis; A. Sudria and A. Rufer " Control of a Multilevel modular DC/DC
converter design for mobile applications" PCIM 2010, pp. 107-110, 4-6 May 2010.
[12] T. Esram and P. L. Chapman " Comparison of Photovoltiac Array Maximum Power Point
Tracking Techniques" IEEE Transactions on Energy Conversion, Vol. 22, pp.439-449, 2007.
[13] A. A. hafez, "simple and robust Maximum Power Point Tracking Algorithm for a solar cell,"
in World Congress on Electronics and Electrical Engineering (WCEEENG'10). 2010, pp.
240-245, April 2010.
International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print),
ISSN 0976 – 6553(Online) Volume 4, Issue 5, September – October (2013), © IAEME
35
[14] KC200GT High Efficiency Multicrystal Photovoltaic Module Datasheet Kyocera:
http://www.kyocera.com.sg/products/solar/ pdf/kc200gt.pdf., 2011
[15] M. Villalva; J. Gazoli and E. R. Filho, "Comprehensive Approach to Modeling and
Simulation of Photovoltaic Arrays," IEEE Transactions on Power Electronics, Vol. 24,
pp. 1198-1208, 2009.
[16] D. Hansen; P. Sørensen; L. Hansen and H. Bindner, “Models for a Stand-Alone PV System”,
Risø-R-1219(EN) / SEC-R-12, 2000
[17] R. S. Burns” Advanced Control Engineering “1st
edition, Butterworth-Heinemann, Oxford,
UK, 2001.
[18] Sahaj Saxena and Yogesh V Hote” Advances in Internal Model Control Technique: A
Review and Future Prospects” IETE Technical Review, Vol. 29, issue 6, pp. 461-472, 2012.
[19] M.Sujith, R.Mohan and P.Sundravadivel, “Simulation Analysis of 100kw Integrated
Segmented Energy Storage for Grid Connected Pv System”, International Journal of
Electrical Engineering & Technology (IJEET), Volume 3, Issue 2, 2012, pp. 164 - 173,
ISSN Print : 0976-6545, ISSN Online: 0976-6553.
[20] Rajasekharachari K, K.Shalini, Kumar .K and S.R.Divya, “Advanced Five Level - Five Phase
Cascaded Multilevel Inverter with SVPWM Algorithm”, International Journal of Electrical
Engineering & Technology (IJEET), Volume 4, Issue 4, 2013, pp. 144 - 158, ISSN Print:
0976-6545, ISSN Online: 0976-6553.
[21] M.Saisesha, V.S.N.Narasimharaju, R.Madhu Sudanarao and M.Balaji, “Control of Power
Inverters in Renewable Energy and Smart Grid Integration”, International Journal of
Electrical Engineering & Technology (IJEET), Volume 4, Issue 1, 2013, pp. 200 - 207,
ISSN Print: 0976-6545, ISSN Online: 0976-6553.

More Related Content

What's hot

IEEE 2013 12 eee B.tech & m.tech
IEEE  2013 12 eee B.tech & m.techIEEE  2013 12 eee B.tech & m.tech
IEEE 2013 12 eee B.tech & m.techVision Solutions
 
Single phase grid connected fuel system based on boost inverter
Single phase grid connected fuel system based on boost inverterSingle phase grid connected fuel system based on boost inverter
Single phase grid connected fuel system based on boost inverterRohithasangaraju
 
An Improved Single Phase Transformer less Inverter Topology for Cost Effecti...
An Improved Single Phase Transformer less Inverter Topology  for Cost Effecti...An Improved Single Phase Transformer less Inverter Topology  for Cost Effecti...
An Improved Single Phase Transformer less Inverter Topology for Cost Effecti...IJMER
 
Design Development and Simulation of Mobile Substation for Distribution Network
Design Development and Simulation of Mobile Substation for Distribution NetworkDesign Development and Simulation of Mobile Substation for Distribution Network
Design Development and Simulation of Mobile Substation for Distribution NetworkIJSRD
 
All ieee 2013
All ieee 2013All ieee 2013
All ieee 2013Ecwayt
 
Partial Shading Detection and MPPT Controller for Total Cross Tied Photovolta...
Partial Shading Detection and MPPT Controller for Total Cross Tied Photovolta...Partial Shading Detection and MPPT Controller for Total Cross Tied Photovolta...
Partial Shading Detection and MPPT Controller for Total Cross Tied Photovolta...IDES Editor
 
PARTICLE INITIATED FOV OF HYBRID CYLINDRICAL INSULATING SPACERS UNDER AC AND ...
PARTICLE INITIATED FOV OF HYBRID CYLINDRICAL INSULATING SPACERS UNDER AC AND ...PARTICLE INITIATED FOV OF HYBRID CYLINDRICAL INSULATING SPACERS UNDER AC AND ...
PARTICLE INITIATED FOV OF HYBRID CYLINDRICAL INSULATING SPACERS UNDER AC AND ...IAEME Publication
 
Power System Analysis unit - I
Power System Analysis unit - IPower System Analysis unit - I
Power System Analysis unit - Iarunatshare
 
All ieee 2013
All ieee 2013All ieee 2013
All ieee 2013Ecwayt
 
Smart Inverters and Their Role in the Modern Electric Grid
Smart Inverters and Their Role in the Modern Electric GridSmart Inverters and Their Role in the Modern Electric Grid
Smart Inverters and Their Role in the Modern Electric GridPower System Operation
 
IRJET- Design and Implementation of Transformerless Mosfet Inverter for a Gri...
IRJET- Design and Implementation of Transformerless Mosfet Inverter for a Gri...IRJET- Design and Implementation of Transformerless Mosfet Inverter for a Gri...
IRJET- Design and Implementation of Transformerless Mosfet Inverter for a Gri...IRJET Journal
 
Operation and Control of Grid Connected Hybrid AC/DC Microgrid using Various RES
Operation and Control of Grid Connected Hybrid AC/DC Microgrid using Various RESOperation and Control of Grid Connected Hybrid AC/DC Microgrid using Various RES
Operation and Control of Grid Connected Hybrid AC/DC Microgrid using Various RESIAES-IJPEDS
 
A Comprehensive Analysis of Partial Shading Effect on Output Parameters of a ...
A Comprehensive Analysis of Partial Shading Effect on Output Parameters of a ...A Comprehensive Analysis of Partial Shading Effect on Output Parameters of a ...
A Comprehensive Analysis of Partial Shading Effect on Output Parameters of a ...IJECEIAES
 
Module 4 power generation & Economics - Substation vtu syllabus
Module 4 power generation & Economics - Substation vtu syllabusModule 4 power generation & Economics - Substation vtu syllabus
Module 4 power generation & Economics - Substation vtu syllabusDrCVMOHAN
 

What's hot (15)

IEEE 2013 12 eee B.tech & m.tech
IEEE  2013 12 eee B.tech & m.techIEEE  2013 12 eee B.tech & m.tech
IEEE 2013 12 eee B.tech & m.tech
 
REU_report_paper
REU_report_paperREU_report_paper
REU_report_paper
 
Single phase grid connected fuel system based on boost inverter
Single phase grid connected fuel system based on boost inverterSingle phase grid connected fuel system based on boost inverter
Single phase grid connected fuel system based on boost inverter
 
An Improved Single Phase Transformer less Inverter Topology for Cost Effecti...
An Improved Single Phase Transformer less Inverter Topology  for Cost Effecti...An Improved Single Phase Transformer less Inverter Topology  for Cost Effecti...
An Improved Single Phase Transformer less Inverter Topology for Cost Effecti...
 
Design Development and Simulation of Mobile Substation for Distribution Network
Design Development and Simulation of Mobile Substation for Distribution NetworkDesign Development and Simulation of Mobile Substation for Distribution Network
Design Development and Simulation of Mobile Substation for Distribution Network
 
All ieee 2013
All ieee 2013All ieee 2013
All ieee 2013
 
Partial Shading Detection and MPPT Controller for Total Cross Tied Photovolta...
Partial Shading Detection and MPPT Controller for Total Cross Tied Photovolta...Partial Shading Detection and MPPT Controller for Total Cross Tied Photovolta...
Partial Shading Detection and MPPT Controller for Total Cross Tied Photovolta...
 
PARTICLE INITIATED FOV OF HYBRID CYLINDRICAL INSULATING SPACERS UNDER AC AND ...
PARTICLE INITIATED FOV OF HYBRID CYLINDRICAL INSULATING SPACERS UNDER AC AND ...PARTICLE INITIATED FOV OF HYBRID CYLINDRICAL INSULATING SPACERS UNDER AC AND ...
PARTICLE INITIATED FOV OF HYBRID CYLINDRICAL INSULATING SPACERS UNDER AC AND ...
 
Power System Analysis unit - I
Power System Analysis unit - IPower System Analysis unit - I
Power System Analysis unit - I
 
All ieee 2013
All ieee 2013All ieee 2013
All ieee 2013
 
Smart Inverters and Their Role in the Modern Electric Grid
Smart Inverters and Their Role in the Modern Electric GridSmart Inverters and Their Role in the Modern Electric Grid
Smart Inverters and Their Role in the Modern Electric Grid
 
IRJET- Design and Implementation of Transformerless Mosfet Inverter for a Gri...
IRJET- Design and Implementation of Transformerless Mosfet Inverter for a Gri...IRJET- Design and Implementation of Transformerless Mosfet Inverter for a Gri...
IRJET- Design and Implementation of Transformerless Mosfet Inverter for a Gri...
 
Operation and Control of Grid Connected Hybrid AC/DC Microgrid using Various RES
Operation and Control of Grid Connected Hybrid AC/DC Microgrid using Various RESOperation and Control of Grid Connected Hybrid AC/DC Microgrid using Various RES
Operation and Control of Grid Connected Hybrid AC/DC Microgrid using Various RES
 
A Comprehensive Analysis of Partial Shading Effect on Output Parameters of a ...
A Comprehensive Analysis of Partial Shading Effect on Output Parameters of a ...A Comprehensive Analysis of Partial Shading Effect on Output Parameters of a ...
A Comprehensive Analysis of Partial Shading Effect on Output Parameters of a ...
 
Module 4 power generation & Economics - Substation vtu syllabus
Module 4 power generation & Economics - Substation vtu syllabusModule 4 power generation & Economics - Substation vtu syllabus
Module 4 power generation & Economics - Substation vtu syllabus
 

Viewers also liked

Viewers also liked (19)

10120130405006
1012013040500610120130405006
10120130405006
 
40220130405004
4022013040500440220130405004
40220130405004
 
50120130405005
5012013040500550120130405005
50120130405005
 
50120130404054
5012013040405450120130404054
50120130404054
 
30120130405010
3012013040501030120130405010
30120130405010
 
20320130405002
2032013040500220320130405002
20320130405002
 
30420130403003
3042013040300330420130403003
30420130403003
 
El sistema excretor
El sistema excretorEl sistema excretor
El sistema excretor
 
Adiós a la estética pg. 29 52 schaffer (1)
Adiós a la estética pg. 29 52 schaffer (1)Adiós a la estética pg. 29 52 schaffer (1)
Adiós a la estética pg. 29 52 schaffer (1)
 
La materia viva
La materia vivaLa materia viva
La materia viva
 
company profile
company profilecompany profile
company profile
 
Essai de caractérisation des portus du Bas-Guadalquivir
Essai de caractérisation des portus du Bas-Guadalquivir Essai de caractérisation des portus du Bas-Guadalquivir
Essai de caractérisation des portus du Bas-Guadalquivir
 
Auberge
AubergeAuberge
Auberge
 
Engineered Hardwood Floor E-catalogue------songlinfloor
Engineered Hardwood Floor E-catalogue------songlinfloorEngineered Hardwood Floor E-catalogue------songlinfloor
Engineered Hardwood Floor E-catalogue------songlinfloor
 
Como obtener lo maximo mac arthur
Como obtener lo maximo mac arthurComo obtener lo maximo mac arthur
Como obtener lo maximo mac arthur
 
turninguptheheat
turninguptheheatturninguptheheat
turninguptheheat
 
Final questionnaire results
Final questionnaire resultsFinal questionnaire results
Final questionnaire results
 
John Siciliano Resume
John Siciliano ResumeJohn Siciliano Resume
John Siciliano Resume
 
Boletín Informativo Tierra num. 212.- 27 septiembre 2013
Boletín Informativo Tierra num. 212.- 27 septiembre 2013Boletín Informativo Tierra num. 212.- 27 septiembre 2013
Boletín Informativo Tierra num. 212.- 27 septiembre 2013
 

Similar to 40220130405003

IRJET- A Review on Solar based Multilevel Inverter with Three Phase Grid Supply
IRJET- A Review on Solar based Multilevel Inverter with Three Phase Grid SupplyIRJET- A Review on Solar based Multilevel Inverter with Three Phase Grid Supply
IRJET- A Review on Solar based Multilevel Inverter with Three Phase Grid SupplyIRJET Journal
 
Ieee xplore full text pdf 44
Ieee xplore full text pdf 44Ieee xplore full text pdf 44
Ieee xplore full text pdf 44sanjiivambati59
 
An intelligent based fault-tolerant system 2018
An intelligent based fault-tolerant system 2018An intelligent based fault-tolerant system 2018
An intelligent based fault-tolerant system 2018Premkumar K
 
Study of grid connected pv system based on current source inverter
Study of grid connected pv system based on current source inverterStudy of grid connected pv system based on current source inverter
Study of grid connected pv system based on current source inverterIAEME Publication
 
Maximum power point tracking of pv arrays under partial shading condition usi...
Maximum power point tracking of pv arrays under partial shading condition usi...Maximum power point tracking of pv arrays under partial shading condition usi...
Maximum power point tracking of pv arrays under partial shading condition usi...eSAT Publishing House
 
FUZZY LOGIC CONTROLLER BASED MPPT METHODS FOR THE MULTILEVEL INVERTERS TO THE...
FUZZY LOGIC CONTROLLER BASED MPPT METHODS FOR THE MULTILEVEL INVERTERS TO THE...FUZZY LOGIC CONTROLLER BASED MPPT METHODS FOR THE MULTILEVEL INVERTERS TO THE...
FUZZY LOGIC CONTROLLER BASED MPPT METHODS FOR THE MULTILEVEL INVERTERS TO THE...IRJET Journal
 
IRJET- Frequency Control of Distributed Generators in Microgrid with ANFIS Co...
IRJET- Frequency Control of Distributed Generators in Microgrid with ANFIS Co...IRJET- Frequency Control of Distributed Generators in Microgrid with ANFIS Co...
IRJET- Frequency Control of Distributed Generators in Microgrid with ANFIS Co...IRJET Journal
 
IRJET- Comparison of H5 and HERIC Trasformerless Inverter Topology Conserning...
IRJET- Comparison of H5 and HERIC Trasformerless Inverter Topology Conserning...IRJET- Comparison of H5 and HERIC Trasformerless Inverter Topology Conserning...
IRJET- Comparison of H5 and HERIC Trasformerless Inverter Topology Conserning...IRJET Journal
 
Grid Connected Solar PV System with SEPIC Converter Based MPPT
Grid Connected Solar PV System with SEPIC Converter Based MPPTGrid Connected Solar PV System with SEPIC Converter Based MPPT
Grid Connected Solar PV System with SEPIC Converter Based MPPTIRJET Journal
 
Analysis and Design of Solar Photo voltaic Grid Connected Inverter
Analysis and Design of Solar Photo voltaic Grid Connected InverterAnalysis and Design of Solar Photo voltaic Grid Connected Inverter
Analysis and Design of Solar Photo voltaic Grid Connected Inverterijeei-iaes
 
Modeling of Hysteresis Current Control Technique for Three Phase PV Based VSI...
Modeling of Hysteresis Current Control Technique for Three Phase PV Based VSI...Modeling of Hysteresis Current Control Technique for Three Phase PV Based VSI...
Modeling of Hysteresis Current Control Technique for Three Phase PV Based VSI...IRJET Journal
 
Reduction of mismatch and shading loss by use
Reduction of mismatch and shading loss by useReduction of mismatch and shading loss by use
Reduction of mismatch and shading loss by useiaemedu
 
Reduction of mismatch and shading loss by use of distributed power electronics
Reduction of mismatch and shading loss by use of distributed power electronicsReduction of mismatch and shading loss by use of distributed power electronics
Reduction of mismatch and shading loss by use of distributed power electronicsIAEME Publication
 
IRJET- Multi-Level Inverter for Solar On-Grid System Design
IRJET- Multi-Level Inverter for Solar On-Grid System DesignIRJET- Multi-Level Inverter for Solar On-Grid System Design
IRJET- Multi-Level Inverter for Solar On-Grid System DesignIRJET Journal
 
IRJET- Grid Integrated Single Phase PV with Shunt Active Filter based Control...
IRJET- Grid Integrated Single Phase PV with Shunt Active Filter based Control...IRJET- Grid Integrated Single Phase PV with Shunt Active Filter based Control...
IRJET- Grid Integrated Single Phase PV with Shunt Active Filter based Control...IRJET Journal
 
A multi converter based pure solar energy system with high efficiency mppt con
A multi converter based pure solar energy system with high efficiency mppt conA multi converter based pure solar energy system with high efficiency mppt con
A multi converter based pure solar energy system with high efficiency mppt conIAEME Publication
 
Fault Ride-Through capability of DSTATCOM for Distributed Wind Generation System
Fault Ride-Through capability of DSTATCOM for Distributed Wind Generation SystemFault Ride-Through capability of DSTATCOM for Distributed Wind Generation System
Fault Ride-Through capability of DSTATCOM for Distributed Wind Generation SystemIJPEDS-IAES
 

Similar to 40220130405003 (20)

IRJET- A Review on Solar based Multilevel Inverter with Three Phase Grid Supply
IRJET- A Review on Solar based Multilevel Inverter with Three Phase Grid SupplyIRJET- A Review on Solar based Multilevel Inverter with Three Phase Grid Supply
IRJET- A Review on Solar based Multilevel Inverter with Three Phase Grid Supply
 
Ieee xplore full text pdf 44
Ieee xplore full text pdf 44Ieee xplore full text pdf 44
Ieee xplore full text pdf 44
 
An intelligent based fault-tolerant system 2018
An intelligent based fault-tolerant system 2018An intelligent based fault-tolerant system 2018
An intelligent based fault-tolerant system 2018
 
40220140504010
4022014050401040220140504010
40220140504010
 
Modeling and Simulation of Grid Connected PV Generation System Using Matlab/S...
Modeling and Simulation of Grid Connected PV Generation System Using Matlab/S...Modeling and Simulation of Grid Connected PV Generation System Using Matlab/S...
Modeling and Simulation of Grid Connected PV Generation System Using Matlab/S...
 
Study of grid connected pv system based on current source inverter
Study of grid connected pv system based on current source inverterStudy of grid connected pv system based on current source inverter
Study of grid connected pv system based on current source inverter
 
Maximum power point tracking of pv arrays under partial shading condition usi...
Maximum power point tracking of pv arrays under partial shading condition usi...Maximum power point tracking of pv arrays under partial shading condition usi...
Maximum power point tracking of pv arrays under partial shading condition usi...
 
FUZZY LOGIC CONTROLLER BASED MPPT METHODS FOR THE MULTILEVEL INVERTERS TO THE...
FUZZY LOGIC CONTROLLER BASED MPPT METHODS FOR THE MULTILEVEL INVERTERS TO THE...FUZZY LOGIC CONTROLLER BASED MPPT METHODS FOR THE MULTILEVEL INVERTERS TO THE...
FUZZY LOGIC CONTROLLER BASED MPPT METHODS FOR THE MULTILEVEL INVERTERS TO THE...
 
Analysis and Design of Single Phase High Efficiency Transformer less PV Inver...
Analysis and Design of Single Phase High Efficiency Transformer less PV Inver...Analysis and Design of Single Phase High Efficiency Transformer less PV Inver...
Analysis and Design of Single Phase High Efficiency Transformer less PV Inver...
 
IRJET- Frequency Control of Distributed Generators in Microgrid with ANFIS Co...
IRJET- Frequency Control of Distributed Generators in Microgrid with ANFIS Co...IRJET- Frequency Control of Distributed Generators in Microgrid with ANFIS Co...
IRJET- Frequency Control of Distributed Generators in Microgrid with ANFIS Co...
 
IRJET- Comparison of H5 and HERIC Trasformerless Inverter Topology Conserning...
IRJET- Comparison of H5 and HERIC Trasformerless Inverter Topology Conserning...IRJET- Comparison of H5 and HERIC Trasformerless Inverter Topology Conserning...
IRJET- Comparison of H5 and HERIC Trasformerless Inverter Topology Conserning...
 
Grid Connected Solar PV System with SEPIC Converter Based MPPT
Grid Connected Solar PV System with SEPIC Converter Based MPPTGrid Connected Solar PV System with SEPIC Converter Based MPPT
Grid Connected Solar PV System with SEPIC Converter Based MPPT
 
Analysis and Design of Solar Photo voltaic Grid Connected Inverter
Analysis and Design of Solar Photo voltaic Grid Connected InverterAnalysis and Design of Solar Photo voltaic Grid Connected Inverter
Analysis and Design of Solar Photo voltaic Grid Connected Inverter
 
Modeling of Hysteresis Current Control Technique for Three Phase PV Based VSI...
Modeling of Hysteresis Current Control Technique for Three Phase PV Based VSI...Modeling of Hysteresis Current Control Technique for Three Phase PV Based VSI...
Modeling of Hysteresis Current Control Technique for Three Phase PV Based VSI...
 
Reduction of mismatch and shading loss by use
Reduction of mismatch and shading loss by useReduction of mismatch and shading loss by use
Reduction of mismatch and shading loss by use
 
Reduction of mismatch and shading loss by use of distributed power electronics
Reduction of mismatch and shading loss by use of distributed power electronicsReduction of mismatch and shading loss by use of distributed power electronics
Reduction of mismatch and shading loss by use of distributed power electronics
 
IRJET- Multi-Level Inverter for Solar On-Grid System Design
IRJET- Multi-Level Inverter for Solar On-Grid System DesignIRJET- Multi-Level Inverter for Solar On-Grid System Design
IRJET- Multi-Level Inverter for Solar On-Grid System Design
 
IRJET- Grid Integrated Single Phase PV with Shunt Active Filter based Control...
IRJET- Grid Integrated Single Phase PV with Shunt Active Filter based Control...IRJET- Grid Integrated Single Phase PV with Shunt Active Filter based Control...
IRJET- Grid Integrated Single Phase PV with Shunt Active Filter based Control...
 
A multi converter based pure solar energy system with high efficiency mppt con
A multi converter based pure solar energy system with high efficiency mppt conA multi converter based pure solar energy system with high efficiency mppt con
A multi converter based pure solar energy system with high efficiency mppt con
 
Fault Ride-Through capability of DSTATCOM for Distributed Wind Generation System
Fault Ride-Through capability of DSTATCOM for Distributed Wind Generation SystemFault Ride-Through capability of DSTATCOM for Distributed Wind Generation System
Fault Ride-Through capability of DSTATCOM for Distributed Wind Generation System
 

More from IAEME Publication

IAEME_Publication_Call_for_Paper_September_2022.pdf
IAEME_Publication_Call_for_Paper_September_2022.pdfIAEME_Publication_Call_for_Paper_September_2022.pdf
IAEME_Publication_Call_for_Paper_September_2022.pdfIAEME Publication
 
MODELING AND ANALYSIS OF SURFACE ROUGHNESS AND WHITE LATER THICKNESS IN WIRE-...
MODELING AND ANALYSIS OF SURFACE ROUGHNESS AND WHITE LATER THICKNESS IN WIRE-...MODELING AND ANALYSIS OF SURFACE ROUGHNESS AND WHITE LATER THICKNESS IN WIRE-...
MODELING AND ANALYSIS OF SURFACE ROUGHNESS AND WHITE LATER THICKNESS IN WIRE-...IAEME Publication
 
A STUDY ON THE REASONS FOR TRANSGENDER TO BECOME ENTREPRENEURS
A STUDY ON THE REASONS FOR TRANSGENDER TO BECOME ENTREPRENEURSA STUDY ON THE REASONS FOR TRANSGENDER TO BECOME ENTREPRENEURS
A STUDY ON THE REASONS FOR TRANSGENDER TO BECOME ENTREPRENEURSIAEME Publication
 
BROAD UNEXPOSED SKILLS OF TRANSGENDER ENTREPRENEURS
BROAD UNEXPOSED SKILLS OF TRANSGENDER ENTREPRENEURSBROAD UNEXPOSED SKILLS OF TRANSGENDER ENTREPRENEURS
BROAD UNEXPOSED SKILLS OF TRANSGENDER ENTREPRENEURSIAEME Publication
 
DETERMINANTS AFFECTING THE USER'S INTENTION TO USE MOBILE BANKING APPLICATIONS
DETERMINANTS AFFECTING THE USER'S INTENTION TO USE MOBILE BANKING APPLICATIONSDETERMINANTS AFFECTING THE USER'S INTENTION TO USE MOBILE BANKING APPLICATIONS
DETERMINANTS AFFECTING THE USER'S INTENTION TO USE MOBILE BANKING APPLICATIONSIAEME Publication
 
ANALYSE THE USER PREDILECTION ON GPAY AND PHONEPE FOR DIGITAL TRANSACTIONS
ANALYSE THE USER PREDILECTION ON GPAY AND PHONEPE FOR DIGITAL TRANSACTIONSANALYSE THE USER PREDILECTION ON GPAY AND PHONEPE FOR DIGITAL TRANSACTIONS
ANALYSE THE USER PREDILECTION ON GPAY AND PHONEPE FOR DIGITAL TRANSACTIONSIAEME Publication
 
VOICE BASED ATM FOR VISUALLY IMPAIRED USING ARDUINO
VOICE BASED ATM FOR VISUALLY IMPAIRED USING ARDUINOVOICE BASED ATM FOR VISUALLY IMPAIRED USING ARDUINO
VOICE BASED ATM FOR VISUALLY IMPAIRED USING ARDUINOIAEME Publication
 
IMPACT OF EMOTIONAL INTELLIGENCE ON HUMAN RESOURCE MANAGEMENT PRACTICES AMONG...
IMPACT OF EMOTIONAL INTELLIGENCE ON HUMAN RESOURCE MANAGEMENT PRACTICES AMONG...IMPACT OF EMOTIONAL INTELLIGENCE ON HUMAN RESOURCE MANAGEMENT PRACTICES AMONG...
IMPACT OF EMOTIONAL INTELLIGENCE ON HUMAN RESOURCE MANAGEMENT PRACTICES AMONG...IAEME Publication
 
VISUALISING AGING PARENTS & THEIR CLOSE CARERS LIFE JOURNEY IN AGING ECONOMY
VISUALISING AGING PARENTS & THEIR CLOSE CARERS LIFE JOURNEY IN AGING ECONOMYVISUALISING AGING PARENTS & THEIR CLOSE CARERS LIFE JOURNEY IN AGING ECONOMY
VISUALISING AGING PARENTS & THEIR CLOSE CARERS LIFE JOURNEY IN AGING ECONOMYIAEME Publication
 
A STUDY ON THE IMPACT OF ORGANIZATIONAL CULTURE ON THE EFFECTIVENESS OF PERFO...
A STUDY ON THE IMPACT OF ORGANIZATIONAL CULTURE ON THE EFFECTIVENESS OF PERFO...A STUDY ON THE IMPACT OF ORGANIZATIONAL CULTURE ON THE EFFECTIVENESS OF PERFO...
A STUDY ON THE IMPACT OF ORGANIZATIONAL CULTURE ON THE EFFECTIVENESS OF PERFO...IAEME Publication
 
GANDHI ON NON-VIOLENT POLICE
GANDHI ON NON-VIOLENT POLICEGANDHI ON NON-VIOLENT POLICE
GANDHI ON NON-VIOLENT POLICEIAEME Publication
 
A STUDY ON TALENT MANAGEMENT AND ITS IMPACT ON EMPLOYEE RETENTION IN SELECTED...
A STUDY ON TALENT MANAGEMENT AND ITS IMPACT ON EMPLOYEE RETENTION IN SELECTED...A STUDY ON TALENT MANAGEMENT AND ITS IMPACT ON EMPLOYEE RETENTION IN SELECTED...
A STUDY ON TALENT MANAGEMENT AND ITS IMPACT ON EMPLOYEE RETENTION IN SELECTED...IAEME Publication
 
ATTRITION IN THE IT INDUSTRY DURING COVID-19 PANDEMIC: LINKING EMOTIONAL INTE...
ATTRITION IN THE IT INDUSTRY DURING COVID-19 PANDEMIC: LINKING EMOTIONAL INTE...ATTRITION IN THE IT INDUSTRY DURING COVID-19 PANDEMIC: LINKING EMOTIONAL INTE...
ATTRITION IN THE IT INDUSTRY DURING COVID-19 PANDEMIC: LINKING EMOTIONAL INTE...IAEME Publication
 
INFLUENCE OF TALENT MANAGEMENT PRACTICES ON ORGANIZATIONAL PERFORMANCE A STUD...
INFLUENCE OF TALENT MANAGEMENT PRACTICES ON ORGANIZATIONAL PERFORMANCE A STUD...INFLUENCE OF TALENT MANAGEMENT PRACTICES ON ORGANIZATIONAL PERFORMANCE A STUD...
INFLUENCE OF TALENT MANAGEMENT PRACTICES ON ORGANIZATIONAL PERFORMANCE A STUD...IAEME Publication
 
A STUDY OF VARIOUS TYPES OF LOANS OF SELECTED PUBLIC AND PRIVATE SECTOR BANKS...
A STUDY OF VARIOUS TYPES OF LOANS OF SELECTED PUBLIC AND PRIVATE SECTOR BANKS...A STUDY OF VARIOUS TYPES OF LOANS OF SELECTED PUBLIC AND PRIVATE SECTOR BANKS...
A STUDY OF VARIOUS TYPES OF LOANS OF SELECTED PUBLIC AND PRIVATE SECTOR BANKS...IAEME Publication
 
EXPERIMENTAL STUDY OF MECHANICAL AND TRIBOLOGICAL RELATION OF NYLON/BaSO4 POL...
EXPERIMENTAL STUDY OF MECHANICAL AND TRIBOLOGICAL RELATION OF NYLON/BaSO4 POL...EXPERIMENTAL STUDY OF MECHANICAL AND TRIBOLOGICAL RELATION OF NYLON/BaSO4 POL...
EXPERIMENTAL STUDY OF MECHANICAL AND TRIBOLOGICAL RELATION OF NYLON/BaSO4 POL...IAEME Publication
 
ROLE OF SOCIAL ENTREPRENEURSHIP IN RURAL DEVELOPMENT OF INDIA - PROBLEMS AND ...
ROLE OF SOCIAL ENTREPRENEURSHIP IN RURAL DEVELOPMENT OF INDIA - PROBLEMS AND ...ROLE OF SOCIAL ENTREPRENEURSHIP IN RURAL DEVELOPMENT OF INDIA - PROBLEMS AND ...
ROLE OF SOCIAL ENTREPRENEURSHIP IN RURAL DEVELOPMENT OF INDIA - PROBLEMS AND ...IAEME Publication
 
OPTIMAL RECONFIGURATION OF POWER DISTRIBUTION RADIAL NETWORK USING HYBRID MET...
OPTIMAL RECONFIGURATION OF POWER DISTRIBUTION RADIAL NETWORK USING HYBRID MET...OPTIMAL RECONFIGURATION OF POWER DISTRIBUTION RADIAL NETWORK USING HYBRID MET...
OPTIMAL RECONFIGURATION OF POWER DISTRIBUTION RADIAL NETWORK USING HYBRID MET...IAEME Publication
 
APPLICATION OF FRUGAL APPROACH FOR PRODUCTIVITY IMPROVEMENT - A CASE STUDY OF...
APPLICATION OF FRUGAL APPROACH FOR PRODUCTIVITY IMPROVEMENT - A CASE STUDY OF...APPLICATION OF FRUGAL APPROACH FOR PRODUCTIVITY IMPROVEMENT - A CASE STUDY OF...
APPLICATION OF FRUGAL APPROACH FOR PRODUCTIVITY IMPROVEMENT - A CASE STUDY OF...IAEME Publication
 
A MULTIPLE – CHANNEL QUEUING MODELS ON FUZZY ENVIRONMENT
A MULTIPLE – CHANNEL QUEUING MODELS ON FUZZY ENVIRONMENTA MULTIPLE – CHANNEL QUEUING MODELS ON FUZZY ENVIRONMENT
A MULTIPLE – CHANNEL QUEUING MODELS ON FUZZY ENVIRONMENTIAEME Publication
 

More from IAEME Publication (20)

IAEME_Publication_Call_for_Paper_September_2022.pdf
IAEME_Publication_Call_for_Paper_September_2022.pdfIAEME_Publication_Call_for_Paper_September_2022.pdf
IAEME_Publication_Call_for_Paper_September_2022.pdf
 
MODELING AND ANALYSIS OF SURFACE ROUGHNESS AND WHITE LATER THICKNESS IN WIRE-...
MODELING AND ANALYSIS OF SURFACE ROUGHNESS AND WHITE LATER THICKNESS IN WIRE-...MODELING AND ANALYSIS OF SURFACE ROUGHNESS AND WHITE LATER THICKNESS IN WIRE-...
MODELING AND ANALYSIS OF SURFACE ROUGHNESS AND WHITE LATER THICKNESS IN WIRE-...
 
A STUDY ON THE REASONS FOR TRANSGENDER TO BECOME ENTREPRENEURS
A STUDY ON THE REASONS FOR TRANSGENDER TO BECOME ENTREPRENEURSA STUDY ON THE REASONS FOR TRANSGENDER TO BECOME ENTREPRENEURS
A STUDY ON THE REASONS FOR TRANSGENDER TO BECOME ENTREPRENEURS
 
BROAD UNEXPOSED SKILLS OF TRANSGENDER ENTREPRENEURS
BROAD UNEXPOSED SKILLS OF TRANSGENDER ENTREPRENEURSBROAD UNEXPOSED SKILLS OF TRANSGENDER ENTREPRENEURS
BROAD UNEXPOSED SKILLS OF TRANSGENDER ENTREPRENEURS
 
DETERMINANTS AFFECTING THE USER'S INTENTION TO USE MOBILE BANKING APPLICATIONS
DETERMINANTS AFFECTING THE USER'S INTENTION TO USE MOBILE BANKING APPLICATIONSDETERMINANTS AFFECTING THE USER'S INTENTION TO USE MOBILE BANKING APPLICATIONS
DETERMINANTS AFFECTING THE USER'S INTENTION TO USE MOBILE BANKING APPLICATIONS
 
ANALYSE THE USER PREDILECTION ON GPAY AND PHONEPE FOR DIGITAL TRANSACTIONS
ANALYSE THE USER PREDILECTION ON GPAY AND PHONEPE FOR DIGITAL TRANSACTIONSANALYSE THE USER PREDILECTION ON GPAY AND PHONEPE FOR DIGITAL TRANSACTIONS
ANALYSE THE USER PREDILECTION ON GPAY AND PHONEPE FOR DIGITAL TRANSACTIONS
 
VOICE BASED ATM FOR VISUALLY IMPAIRED USING ARDUINO
VOICE BASED ATM FOR VISUALLY IMPAIRED USING ARDUINOVOICE BASED ATM FOR VISUALLY IMPAIRED USING ARDUINO
VOICE BASED ATM FOR VISUALLY IMPAIRED USING ARDUINO
 
IMPACT OF EMOTIONAL INTELLIGENCE ON HUMAN RESOURCE MANAGEMENT PRACTICES AMONG...
IMPACT OF EMOTIONAL INTELLIGENCE ON HUMAN RESOURCE MANAGEMENT PRACTICES AMONG...IMPACT OF EMOTIONAL INTELLIGENCE ON HUMAN RESOURCE MANAGEMENT PRACTICES AMONG...
IMPACT OF EMOTIONAL INTELLIGENCE ON HUMAN RESOURCE MANAGEMENT PRACTICES AMONG...
 
VISUALISING AGING PARENTS & THEIR CLOSE CARERS LIFE JOURNEY IN AGING ECONOMY
VISUALISING AGING PARENTS & THEIR CLOSE CARERS LIFE JOURNEY IN AGING ECONOMYVISUALISING AGING PARENTS & THEIR CLOSE CARERS LIFE JOURNEY IN AGING ECONOMY
VISUALISING AGING PARENTS & THEIR CLOSE CARERS LIFE JOURNEY IN AGING ECONOMY
 
A STUDY ON THE IMPACT OF ORGANIZATIONAL CULTURE ON THE EFFECTIVENESS OF PERFO...
A STUDY ON THE IMPACT OF ORGANIZATIONAL CULTURE ON THE EFFECTIVENESS OF PERFO...A STUDY ON THE IMPACT OF ORGANIZATIONAL CULTURE ON THE EFFECTIVENESS OF PERFO...
A STUDY ON THE IMPACT OF ORGANIZATIONAL CULTURE ON THE EFFECTIVENESS OF PERFO...
 
GANDHI ON NON-VIOLENT POLICE
GANDHI ON NON-VIOLENT POLICEGANDHI ON NON-VIOLENT POLICE
GANDHI ON NON-VIOLENT POLICE
 
A STUDY ON TALENT MANAGEMENT AND ITS IMPACT ON EMPLOYEE RETENTION IN SELECTED...
A STUDY ON TALENT MANAGEMENT AND ITS IMPACT ON EMPLOYEE RETENTION IN SELECTED...A STUDY ON TALENT MANAGEMENT AND ITS IMPACT ON EMPLOYEE RETENTION IN SELECTED...
A STUDY ON TALENT MANAGEMENT AND ITS IMPACT ON EMPLOYEE RETENTION IN SELECTED...
 
ATTRITION IN THE IT INDUSTRY DURING COVID-19 PANDEMIC: LINKING EMOTIONAL INTE...
ATTRITION IN THE IT INDUSTRY DURING COVID-19 PANDEMIC: LINKING EMOTIONAL INTE...ATTRITION IN THE IT INDUSTRY DURING COVID-19 PANDEMIC: LINKING EMOTIONAL INTE...
ATTRITION IN THE IT INDUSTRY DURING COVID-19 PANDEMIC: LINKING EMOTIONAL INTE...
 
INFLUENCE OF TALENT MANAGEMENT PRACTICES ON ORGANIZATIONAL PERFORMANCE A STUD...
INFLUENCE OF TALENT MANAGEMENT PRACTICES ON ORGANIZATIONAL PERFORMANCE A STUD...INFLUENCE OF TALENT MANAGEMENT PRACTICES ON ORGANIZATIONAL PERFORMANCE A STUD...
INFLUENCE OF TALENT MANAGEMENT PRACTICES ON ORGANIZATIONAL PERFORMANCE A STUD...
 
A STUDY OF VARIOUS TYPES OF LOANS OF SELECTED PUBLIC AND PRIVATE SECTOR BANKS...
A STUDY OF VARIOUS TYPES OF LOANS OF SELECTED PUBLIC AND PRIVATE SECTOR BANKS...A STUDY OF VARIOUS TYPES OF LOANS OF SELECTED PUBLIC AND PRIVATE SECTOR BANKS...
A STUDY OF VARIOUS TYPES OF LOANS OF SELECTED PUBLIC AND PRIVATE SECTOR BANKS...
 
EXPERIMENTAL STUDY OF MECHANICAL AND TRIBOLOGICAL RELATION OF NYLON/BaSO4 POL...
EXPERIMENTAL STUDY OF MECHANICAL AND TRIBOLOGICAL RELATION OF NYLON/BaSO4 POL...EXPERIMENTAL STUDY OF MECHANICAL AND TRIBOLOGICAL RELATION OF NYLON/BaSO4 POL...
EXPERIMENTAL STUDY OF MECHANICAL AND TRIBOLOGICAL RELATION OF NYLON/BaSO4 POL...
 
ROLE OF SOCIAL ENTREPRENEURSHIP IN RURAL DEVELOPMENT OF INDIA - PROBLEMS AND ...
ROLE OF SOCIAL ENTREPRENEURSHIP IN RURAL DEVELOPMENT OF INDIA - PROBLEMS AND ...ROLE OF SOCIAL ENTREPRENEURSHIP IN RURAL DEVELOPMENT OF INDIA - PROBLEMS AND ...
ROLE OF SOCIAL ENTREPRENEURSHIP IN RURAL DEVELOPMENT OF INDIA - PROBLEMS AND ...
 
OPTIMAL RECONFIGURATION OF POWER DISTRIBUTION RADIAL NETWORK USING HYBRID MET...
OPTIMAL RECONFIGURATION OF POWER DISTRIBUTION RADIAL NETWORK USING HYBRID MET...OPTIMAL RECONFIGURATION OF POWER DISTRIBUTION RADIAL NETWORK USING HYBRID MET...
OPTIMAL RECONFIGURATION OF POWER DISTRIBUTION RADIAL NETWORK USING HYBRID MET...
 
APPLICATION OF FRUGAL APPROACH FOR PRODUCTIVITY IMPROVEMENT - A CASE STUDY OF...
APPLICATION OF FRUGAL APPROACH FOR PRODUCTIVITY IMPROVEMENT - A CASE STUDY OF...APPLICATION OF FRUGAL APPROACH FOR PRODUCTIVITY IMPROVEMENT - A CASE STUDY OF...
APPLICATION OF FRUGAL APPROACH FOR PRODUCTIVITY IMPROVEMENT - A CASE STUDY OF...
 
A MULTIPLE – CHANNEL QUEUING MODELS ON FUZZY ENVIRONMENT
A MULTIPLE – CHANNEL QUEUING MODELS ON FUZZY ENVIRONMENTA MULTIPLE – CHANNEL QUEUING MODELS ON FUZZY ENVIRONMENT
A MULTIPLE – CHANNEL QUEUING MODELS ON FUZZY ENVIRONMENT
 

Recently uploaded

Call Girls In DLf Gurgaon ➥99902@11544 ( Best price)100% Genuine Escort In 24...
Call Girls In DLf Gurgaon ➥99902@11544 ( Best price)100% Genuine Escort In 24...Call Girls In DLf Gurgaon ➥99902@11544 ( Best price)100% Genuine Escort In 24...
Call Girls In DLf Gurgaon ➥99902@11544 ( Best price)100% Genuine Escort In 24...lizamodels9
 
Yaroslav Rozhankivskyy: Три складові і три передумови максимальної продуктивн...
Yaroslav Rozhankivskyy: Три складові і три передумови максимальної продуктивн...Yaroslav Rozhankivskyy: Три складові і три передумови максимальної продуктивн...
Yaroslav Rozhankivskyy: Три складові і три передумови максимальної продуктивн...Lviv Startup Club
 
Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...
Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...
Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...anilsa9823
 
Creating Low-Code Loan Applications using the Trisotech Mortgage Feature Set
Creating Low-Code Loan Applications using the Trisotech Mortgage Feature SetCreating Low-Code Loan Applications using the Trisotech Mortgage Feature Set
Creating Low-Code Loan Applications using the Trisotech Mortgage Feature SetDenis Gagné
 
B.COM Unit – 4 ( CORPORATE SOCIAL RESPONSIBILITY ( CSR ).pptx
B.COM Unit – 4 ( CORPORATE SOCIAL RESPONSIBILITY ( CSR ).pptxB.COM Unit – 4 ( CORPORATE SOCIAL RESPONSIBILITY ( CSR ).pptx
B.COM Unit – 4 ( CORPORATE SOCIAL RESPONSIBILITY ( CSR ).pptxpriyanshujha201
 
Grateful 7 speech thanking everyone that has helped.pdf
Grateful 7 speech thanking everyone that has helped.pdfGrateful 7 speech thanking everyone that has helped.pdf
Grateful 7 speech thanking everyone that has helped.pdfPaul Menig
 
Call Girls Pune Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Pune Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Pune Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Pune Just Call 9907093804 Top Class Call Girl Service AvailableDipal Arora
 
Regression analysis: Simple Linear Regression Multiple Linear Regression
Regression analysis:  Simple Linear Regression Multiple Linear RegressionRegression analysis:  Simple Linear Regression Multiple Linear Regression
Regression analysis: Simple Linear Regression Multiple Linear RegressionRavindra Nath Shukla
 
The Path to Product Excellence: Avoiding Common Pitfalls and Enhancing Commun...
The Path to Product Excellence: Avoiding Common Pitfalls and Enhancing Commun...The Path to Product Excellence: Avoiding Common Pitfalls and Enhancing Commun...
The Path to Product Excellence: Avoiding Common Pitfalls and Enhancing Commun...Aggregage
 
Pharma Works Profile of Karan Communications
Pharma Works Profile of Karan CommunicationsPharma Works Profile of Karan Communications
Pharma Works Profile of Karan Communicationskarancommunications
 
Ensure the security of your HCL environment by applying the Zero Trust princi...
Ensure the security of your HCL environment by applying the Zero Trust princi...Ensure the security of your HCL environment by applying the Zero Trust princi...
Ensure the security of your HCL environment by applying the Zero Trust princi...Roland Driesen
 
Call Girls In Panjim North Goa 9971646499 Genuine Service
Call Girls In Panjim North Goa 9971646499 Genuine ServiceCall Girls In Panjim North Goa 9971646499 Genuine Service
Call Girls In Panjim North Goa 9971646499 Genuine Serviceritikaroy0888
 
Understanding the Pakistan Budgeting Process: Basics and Key Insights
Understanding the Pakistan Budgeting Process: Basics and Key InsightsUnderstanding the Pakistan Budgeting Process: Basics and Key Insights
Understanding the Pakistan Budgeting Process: Basics and Key Insightsseri bangash
 
Call Girls in Delhi, Escort Service Available 24x7 in Delhi 959961-/-3876
Call Girls in Delhi, Escort Service Available 24x7 in Delhi 959961-/-3876Call Girls in Delhi, Escort Service Available 24x7 in Delhi 959961-/-3876
Call Girls in Delhi, Escort Service Available 24x7 in Delhi 959961-/-3876dlhescort
 
KYC-Verified Accounts: Helping Companies Handle Challenging Regulatory Enviro...
KYC-Verified Accounts: Helping Companies Handle Challenging Regulatory Enviro...KYC-Verified Accounts: Helping Companies Handle Challenging Regulatory Enviro...
KYC-Verified Accounts: Helping Companies Handle Challenging Regulatory Enviro...Any kyc Account
 
Event mailer assignment progress report .pdf
Event mailer assignment progress report .pdfEvent mailer assignment progress report .pdf
Event mailer assignment progress report .pdftbatkhuu1
 
A DAY IN THE LIFE OF A SALESMAN / WOMAN
A DAY IN THE LIFE OF A  SALESMAN / WOMANA DAY IN THE LIFE OF A  SALESMAN / WOMAN
A DAY IN THE LIFE OF A SALESMAN / WOMANIlamathiKannappan
 
It will be International Nurses' Day on 12 May
It will be International Nurses' Day on 12 MayIt will be International Nurses' Day on 12 May
It will be International Nurses' Day on 12 MayNZSG
 

Recently uploaded (20)

VVVIP Call Girls In Greater Kailash ➡️ Delhi ➡️ 9999965857 🚀 No Advance 24HRS...
VVVIP Call Girls In Greater Kailash ➡️ Delhi ➡️ 9999965857 🚀 No Advance 24HRS...VVVIP Call Girls In Greater Kailash ➡️ Delhi ➡️ 9999965857 🚀 No Advance 24HRS...
VVVIP Call Girls In Greater Kailash ➡️ Delhi ➡️ 9999965857 🚀 No Advance 24HRS...
 
Call Girls In DLf Gurgaon ➥99902@11544 ( Best price)100% Genuine Escort In 24...
Call Girls In DLf Gurgaon ➥99902@11544 ( Best price)100% Genuine Escort In 24...Call Girls In DLf Gurgaon ➥99902@11544 ( Best price)100% Genuine Escort In 24...
Call Girls In DLf Gurgaon ➥99902@11544 ( Best price)100% Genuine Escort In 24...
 
Yaroslav Rozhankivskyy: Три складові і три передумови максимальної продуктивн...
Yaroslav Rozhankivskyy: Три складові і три передумови максимальної продуктивн...Yaroslav Rozhankivskyy: Три складові і три передумови максимальної продуктивн...
Yaroslav Rozhankivskyy: Три складові і три передумови максимальної продуктивн...
 
Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...
Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...
Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...
 
Creating Low-Code Loan Applications using the Trisotech Mortgage Feature Set
Creating Low-Code Loan Applications using the Trisotech Mortgage Feature SetCreating Low-Code Loan Applications using the Trisotech Mortgage Feature Set
Creating Low-Code Loan Applications using the Trisotech Mortgage Feature Set
 
B.COM Unit – 4 ( CORPORATE SOCIAL RESPONSIBILITY ( CSR ).pptx
B.COM Unit – 4 ( CORPORATE SOCIAL RESPONSIBILITY ( CSR ).pptxB.COM Unit – 4 ( CORPORATE SOCIAL RESPONSIBILITY ( CSR ).pptx
B.COM Unit – 4 ( CORPORATE SOCIAL RESPONSIBILITY ( CSR ).pptx
 
Grateful 7 speech thanking everyone that has helped.pdf
Grateful 7 speech thanking everyone that has helped.pdfGrateful 7 speech thanking everyone that has helped.pdf
Grateful 7 speech thanking everyone that has helped.pdf
 
Call Girls Pune Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Pune Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Pune Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Pune Just Call 9907093804 Top Class Call Girl Service Available
 
Regression analysis: Simple Linear Regression Multiple Linear Regression
Regression analysis:  Simple Linear Regression Multiple Linear RegressionRegression analysis:  Simple Linear Regression Multiple Linear Regression
Regression analysis: Simple Linear Regression Multiple Linear Regression
 
The Path to Product Excellence: Avoiding Common Pitfalls and Enhancing Commun...
The Path to Product Excellence: Avoiding Common Pitfalls and Enhancing Commun...The Path to Product Excellence: Avoiding Common Pitfalls and Enhancing Commun...
The Path to Product Excellence: Avoiding Common Pitfalls and Enhancing Commun...
 
Pharma Works Profile of Karan Communications
Pharma Works Profile of Karan CommunicationsPharma Works Profile of Karan Communications
Pharma Works Profile of Karan Communications
 
Ensure the security of your HCL environment by applying the Zero Trust princi...
Ensure the security of your HCL environment by applying the Zero Trust princi...Ensure the security of your HCL environment by applying the Zero Trust princi...
Ensure the security of your HCL environment by applying the Zero Trust princi...
 
Forklift Operations: Safety through Cartoons
Forklift Operations: Safety through CartoonsForklift Operations: Safety through Cartoons
Forklift Operations: Safety through Cartoons
 
Call Girls In Panjim North Goa 9971646499 Genuine Service
Call Girls In Panjim North Goa 9971646499 Genuine ServiceCall Girls In Panjim North Goa 9971646499 Genuine Service
Call Girls In Panjim North Goa 9971646499 Genuine Service
 
Understanding the Pakistan Budgeting Process: Basics and Key Insights
Understanding the Pakistan Budgeting Process: Basics and Key InsightsUnderstanding the Pakistan Budgeting Process: Basics and Key Insights
Understanding the Pakistan Budgeting Process: Basics and Key Insights
 
Call Girls in Delhi, Escort Service Available 24x7 in Delhi 959961-/-3876
Call Girls in Delhi, Escort Service Available 24x7 in Delhi 959961-/-3876Call Girls in Delhi, Escort Service Available 24x7 in Delhi 959961-/-3876
Call Girls in Delhi, Escort Service Available 24x7 in Delhi 959961-/-3876
 
KYC-Verified Accounts: Helping Companies Handle Challenging Regulatory Enviro...
KYC-Verified Accounts: Helping Companies Handle Challenging Regulatory Enviro...KYC-Verified Accounts: Helping Companies Handle Challenging Regulatory Enviro...
KYC-Verified Accounts: Helping Companies Handle Challenging Regulatory Enviro...
 
Event mailer assignment progress report .pdf
Event mailer assignment progress report .pdfEvent mailer assignment progress report .pdf
Event mailer assignment progress report .pdf
 
A DAY IN THE LIFE OF A SALESMAN / WOMAN
A DAY IN THE LIFE OF A  SALESMAN / WOMANA DAY IN THE LIFE OF A  SALESMAN / WOMAN
A DAY IN THE LIFE OF A SALESMAN / WOMAN
 
It will be International Nurses' Day on 12 May
It will be International Nurses' Day on 12 MayIt will be International Nurses' Day on 12 May
It will be International Nurses' Day on 12 May
 

40220130405003

  • 1. International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 5, September – October (2013), © IAEME 20 ANALYSIS AND DESIGN OF ROBUST CASCADED PV SYSTEM Ahmed A. A. Hafez Electrical Engineering Department, Faculty of Engineering, Assiut University, Assiut, Egypt, PO 71516 ABSTRACT This paper proposes multi-level cascaded DC/DC system for Photovoltaic (PV) application. Three PV generators each coupled to a half-bridge buck cell. Each PV-generator-buck-converter channel is controlled such that maximum power is capture independently under different irradiation and temperature levels. The system operation under normal and abnormal conditions was comprehensively investigated. Simple and robust remedial strategies were proposed to mitigate different anticipated faults. Comprehensive simulation results in Matlab environment were illustrated for corroborating the performance of the advised cascaded DC/DC system under normal/abnormal conditions. Keywords: Multi-level DC/DC, Half-bridge Buck Converter, Internal Mode Control, Faulty Operation, Remedial Strategies. I. INTRODUCTION Energy independence and environmental compatibility are two salient features of PV systems. The fuel is free, and no noise or pollution is created from operating PV systems [1-3]. Thus, PV systems are considered to be from the future trendsetters for securing eco-friendly, sustainable and albeit inexpensive electricity. The basic solar cell usually operates at less than 1 V. Therefore, these cells are arranged in series-parallel configuration (PV module) to increase the output voltage, current and power [1-2]. For high voltage/power levels, the PV modules are arranged in series arrangement (PV panel) to ensure high operating efficiency. However, such arrangements have many disadvantages such as [4]: a mismatch between the characteristics of the modules in the same panel always exists due to modules different orientations and/or manufacturing processes. These modules, however, are restricted to conduct the same current, which limits the panel efficiency to that of the least efficient module/cell. Moreover, the generated current/power drops significantly, when a single cell/module is INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET) ISSN 0976 – 6545(Print) ISSN 0976 – 6553(Online) Volume 4, Issue 5, September – October (2013), pp. 20-35 © IAEME: www.iaeme.com/ijeet.asp Journal Impact Factor (2013): 5.5028 (Calculated by GISI) www.jifactor.com IJEET © I A E M E
  • 2. International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 5, September – October (2013), © IAEME 21 partial/fully shaded. To limit the power loss, a bypassing diode around the shaded module has to be utilized. However, the power from the shaded module is lost under these circumstances [5-7]. A proposed solution [4-11] is to place a separate DC/DC chopper across each PV module. The outputs of the choppers are series connected to obtain high DC voltage level. This allows the system to be transformer free, which boosts the efficiency and reduces cost, volume and weight. Furthermore, attaching a separate DC/DC chopper to each module has the advantage of decoupling the modules. This allows the maximum power point of each module to be tracked independently. Moreover, a shaded module has no impact on the remaining modules, as it could be bypassed through the corresponding DC/DC converter. Furthermore, a fault within PV module/converter disables only the faulted module-converter, while the system can continue functioning albeit at reduced capacity. A little was reported about cascaded DC-DC choppers particularly for PV applications [4-7]. A simple and efficient maximum power point tracker is introduced in [4]. This MPPT is claimed to allow the DC-DC converters to be serially connected in the output side and operate correctly without any additional requirements, however, no detailed analysis is reported in [4] of such series connection. Buck, boost, buck-boost and cuk C-DC converter topologies were compared regarding steady-state efficiency in [8] for the cascaded operation. The buck-boost and cuk topologies suffer from poor switch utilization achieving maximum of 25% at a duty cycle of 50%. Moreover, the buck-boost topology has discontinuous input/output currents, and the cuk topology has extra energy storage components. Ref. [8] concluded that buck and boost topologies should be subjected to further comparison to identify the optimal topology. However, [8] introduces neither control techniques nor dynamic performance. In a cascaded PV system, the DC/DC converter forces the corresponding PV generator to operate at Maximum Power Point (MPP) under varying conditions. Various MPP tracking techniques were reported in literature [12-15]. The incremental conductance is a wide adopted MPP tracker, due to its ability of tracking MPP at wide range of irradiation and temperature levels [12-15]. In this paper, a multi-level cascaded DC/DC converter system for PV application is proposed. An innovative implementation of incremental conductance MPPT is also proposed. This modified MPPT allows almost instantaneous tracking for MPP of each PV generator irrespective to climatologically conditions and/or other PV generators. Therefore, each module PV generator- DC/DC converter is decoupled from the remaining to achieve fault-tolerant system. The proposed compensator is tuned using Internal Mode Control (IMC). The paper introduces also a detailed analysis for the system operation under steady-state and transient conditions. Moreover, the system performance under different types of faults is thoroughly examined. II. TOPLOGY OF DC/DC CONVERTER The boost and buck are most promising topologies for cascaded system. The boost characteristics allow the use of minimum number of PV modules to obtain a high DC voltage level. Moreover, the input inductor reduces the ripples in currents of the PV generators. However, the boost topology in PV cascaded system has a serious problem. The series connection forces equal output currents, and in the boost cell Iin > Iout is an operational constraint. Therefore, if a PV generator is shaded, its current drops significantly and hence the power of the entire system. Thus, the boost topology is inappropriate for series connection. However, it may work satisfactory in the parallel cascaded systems. In the parallel operation of boost-based cascaded system, the system output current is a summation for the output currents of the parallel modules. Thus, if a PV generator encounters shading, its current drops and hence the output current of this faulty module. The
  • 3. International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 5, September – October (2013), © IAEME 22 remaining modules are still functioning normally, and the system output power/current is albeit reduced, Fig. 1. Fig. 1. Multi-level cascaded DC/DC boost converters attached to PV generators, faulty PV generator (grey), series connected (left), parallel connected (right) The buck topology can track the MPP at wide climatological conditions. Moreover, in the buck based cascaded system, each channel, PV generator coupled to a buck converter, is entirely decoupled from the remaining channels. Furthermore, in the buck topologies, the semiconductors arrangement ensures continuous system operation under fault disabling a PV generator. As the freewheeling diode provide alternative path for the current under PV generator failure. This scenario is shown in Fig. 2. Fig. 2. Multi-level cascaded DC/DC buck converters attached to PV generators, faulty PV generator (grey) III. SYSTEM ARCHITECTURE The system under concern, Fig, 3, is composed of three PV generators, each coupled to a half-bridge buck converter. The unit composed of a PV generator, buck converter and the associated controller is defined here as a channel. The half-bridge is used in the system under concern due to its availability, modularity and ease of packaging. Moreover, the half-bridge allows the deployment of a modulation strategy, which reduces the generated harmonics and filter size without comprising the efficiency. The half-bridge buck cell has also bidirectional power flow capability, which could be utilized in interfacing different types of energy storage devices into the DC bus. These energy storage elements are usually deployed in cascaded system to optimize system performance and ensure interruptible system operation. The half-bridges are in series in the output side. An independent controller for each bridge is used. The controller forces the PV generator to operate at their MPP independently. Moreover, it maintains the decoupling between the PV generators and the buck converters.
  • 4. International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 5, September – October (2013), © IAEME 23 1 Vpv 2 Vpv o1 V o2 V V out 1 L 2 L 3 Vpv o3 V 3 L t1 I t2 I t3 I o1 I o2 I o3 I 1 G 1 T 2 G 2 T 2 G 2 T Fig. 3. Multi-level Cascaded DC/DC half-bridge converters attached to PV generators A. PV Generator Different models are proposed for stimulating PV cell, these models vary in accuracy and complexity. Moderate model is proposed here, the PV cell is modeled as a solar irradiation and temperature dependent current source Iph in parallel with diode. This combination is in series with a series resistance Rs [8]. This model of the PV cell has the advantages of accuracy, robustness and simplicity. Basically the PV cells are grouped in series to deliver a reasonable voltage/power, these structures as mentioned before are themed modules. The module has an equivalent circuit similar to that of the cell. s R ph I t I t V Fig. 4. Equivalent circuit of PV cell/module The relation between the terminal current It and voltage Vt of a PV module is expressed by, t s th t ph o V +IR V I =I -I e -1           (1) where Io, Iph, I and V are saturation current, photo current, current and voltage of the module respectively. Vth =nNskT/q is thermal voltage of the module; n, Ns , K, T and q are ideality factor, number of cells in series, Boltz’s man constant and electron charge respectively. The PV modules under concern are from Kyocera KC200GT type. The parameters of KC200GT module are given in Table 1 [16].
  • 5. International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 5, September – October (2013), © IAEME 24 TABLE I PARAMETERS OF KC200GT SOLAR MODULE AT 25O C AND 1000W2 M-2 [16] No. of cells 54 Short circuit current 8.21A Open circuit voltage 32.9V Current at MPP 7.61A Voltage at MPP 26.3V Maximum power 200.143W Voltage coefficient -0.1230V/K Current coefficient 0.0032A/K The value and series resistance Rs calculated by iterative method in [8] is 0.221 . The PV modules are grouped in series-parallel arrangement to form array, which is termed here as PV generator. Each PV generator is consisting of 30 Kyocera KC200GT modules. The relation between the PV array/generator terminal voltage Vpv and current Ipv could be expressed by a relation similarly to (1), however it more meaningful to express the PV array/generator current in terms of the voltage, short-circuit current Isc and open-circuit voltage Voc of the module, as these data are commonly supplied by the manufacturers at standard conditions. Thus the terminal current Ipv is given in terms of terminal voltage Vpv, short-circuit current Isc and open-circuit voltage Voc by, ss pv s pv ss oc ss pv ss sc ss th N I R V -N V + M ) N V I =M I 1-exp(            (2) where Mss and Nss are number of shunt and series connected modules respectively. The current Ipv and the voltage Vpv of the PV array/generator under concern calculated at 25o C and different radiation levels are given in Fig. 5. 0 100 200 300 400 500 600 700 0 2 4 6 8 10 12 14 16 18 20 Voltage (V) Power(kW),current(A) I-V 1kW 2 m -2 P-V 1kW 2 m -2 I-V 0.75kW 2 m -2 P-V 0.75kW 2 m -2 I-V 0.5kW 2 m -2 P-V 0.5kW 2 m -2 I-V 0.25kW 2 m -2 P-V 0.25kW 2 m -2 I-V for maximum power P-V for maximum power Fig. 5. Current and power of a PV generator against terminal voltage for 25o C temperature and different levels of solar irradiance, locus of maximum power (black) Figs. 5 reveals that the voltage at maximum power is less dependent on the solar irradiation [13]. Moreover, the generator current/power varies almost linearly with the insolation.
  • 6. International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 5, September – October (2013), © IAEME 25 In the series-connected system, Fig. 3, the steady-state output currents are equal o1 I = o2 I = o3 I . Assuming lossless system, the output voltage of each bridge oi V depends on the DC-link voltage VDC and the ratio of cell power to that of the entire system as given in (3), * DC ini oi ini i=1 P P V V = m ∑ (3) where m is number of the series converter/channels. Equation (3) indicates that for series- connected system, Fig. 2, when the PV generators have the same solar irradiance levels, the output powers are nearly equal, and thus the output voltages of the correspondences buck bridges. However, as a PV generator is partially/fully shaded, the output voltages of bridges are affected. The shaded module experiences reduction in the output voltage, while the unshaded modules undergo over voltage. Moreover, although the unshaded PV generators still deliver the same power, the system output current will be reduced. B. Half-bridge Converter In the system under concern, a separate inductor filter is attached to each half-bridge converter, Fig. 3. These inductors can be lamped into a single inductor allocated in output side without affecting either dynamic or static performances. However, the distributed inductor topology has the advantages of modularity, ease of upgrading and cost-effectiveness. Since the system can be expanded/contracted by adding/removing a half-bridge with its associate filter inductor. Employing shift switching modulation strategy in the proposed system reduces the current ripple and inductor size, while maintaining high efficiency. As the switching frequency is kept constant at fs, meanwhile the harmonics in the inductor voltage are shifted to m*fs. In the shift switching technique, the carrier waveforms are delayed by 2π/m from each another. The total output inductance could be calculated by, ( )( )V V 1 D Dmax max maxmin L=mL =i mf Is o − − ∆ (4) where Io is ripple in the output current; Dmax is equivalent duty cycle, where maximum ripple occurs, and it is equal to 0.5. Vmax and Vmin are defined by, 1 1 V =V D-Dmod +max pvi m m       (5) 1 V =V D-Dmodmin pvi m       (6) where D is the operating duty cycle and mod is the modulus function. The total inductance L computed for 5% ripple in the output current at 1000w/m2 solar irradiance and 25o C temperature is 0.9mH.
  • 7. International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 5, September – October (2013), © IAEME 26 C. MPPT The slope of power-voltage curve of a PV generator could be expressed by, pv pv pv pv pv pv V dV dV dP dI =I + , (7) The slope of power-voltage curve of a PV module, Fig. 5, is positive on the left of MPP, negative on the right and zero at MPP. Thus the relation between the incremental and instantaneous conductance is given by, pv pv pv pv pv pv pv pv pv pv pv pv , left MPP V V , at MPP V V , right MPP V V I I - I I =- I I - ∆ ∆ ∆ ∆ ∆ ∆ f p , (8) MPP is tracked by continuously comparing the incremental and instantaneous conductance and incrementing/decrementing the PV voltage/current until MPP is reached. This technique is reported in the literature under Incremental Conductance Controller (ICC) [13-15]. An innovative implementation for ICC is proposed here under the theme of Modified Incremental Conduction Controller (MICC). According to (7), the sum of the incremental and instantaneous conductance is equal to zero at MPP; therefore employing a sufficiently fast PI controller ensures that sum is settled at zero. pv pv pv pvV V I I E = + ∆ ∆ , (9) D. Tuning of the controller Each channel, PV generator coupled to buck converter, is controlled individually, thus the cascaded system is modeled for control purpose as single PV generator converter channel as shown in Fig. 6. pv V pv I Vo Io Ls L R Fig. 6. Schematic of single channel and control circuit To simplify the controller design, the cascaded system is assumed to be loaded by a pure resistive load. The sum of incremental and instantaneous conductance is compared with zero, to force system operation at MPP; then the error is supplied to Proportional Integral (PI) controller. The output signal of the PI compensator is used to generate the switching signal.
  • 8. International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 5, September – October (2013), © IAEME 27 The top and bottom switches operate in complementary fashion; for example, when the top switch is on the bottom one is off and vice versa. Thus, when the top switch is on, the system in Fig. 6 could be expressed mathematically by, s o pv o L L dv V = +v R dt (10) During the top switch off state, the system is expressed by, s o o L L dv 0= +v R dt (11) Averaging (10) and (11) over a switching cycle, s o pv o L L dv V D= +v R dt (12) where d is duty cycle. The voltage of PV generator at MPP is assumed constant, thus the system could be considered as single pole system as, ( ) ( ) pvo s s L Vv s =G s = D(s) 1+sL /R (13) A PI controller is tuned using IMC technique. The IMC is extracted from the internal mode principle that states the control can be achieved if the control system encapsulates, either implicitly or explicitly, some representation of the process to be controlled. A thoroughly discussion for the IMC are given in refs. [17,18]. In this work, the design of the controller is only addressed. Assuming that the model of the process, controlled system, ( )PG s has the same transfer function as the process itself, ( )sG s . ( ) ( ) pv P s s L V G s =G s = 1+sL /R (14) Separating the model of the process into invertible ( )+ P G s and non-invertible ( )- P G s components respectively, the controller of the IMC is given by ( ) ( ) ( ) + -1 s L IMC p k pv f 1+sL /R C s =G s = V 1+t s (15) where tf and k are the parameter and the order of the filter. The parameter and the order of the filter are chosen such that the bandwidth of this controller is high enough to provide acceptable tracking for any abrupt change in solar irradiation/temperature. In meanwhile, the controller has the ability to provide adequate attenuation for switching ripples in the PV generator voltage and current. The merits of the IMC technique are [17,18] : 1. simplicity, 2. cost-effectiveness, 3. time-delay compensation, 4. offset free response and 5. good tracking for the setpoint and disturbance rejection.
  • 9. International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 5, September – October (2013), © IAEME 28 The frequency response of closed loop transfer function Vo/ Erref is shown in Fig. 7. -35 -30 -25 -20 -15 -10 -5 0 Magnitudeof∆∆∆∆Vo /∆∆∆∆Erref (dB) 10 0 10 1 10 2 10 3 10 4 10 5 10 6 10 7 10 8 -90 -45 0 Phaseo(deg)∆∆∆∆Vo /∆∆∆∆Erref (degree) Frequency (rad/sec) Fig. 7. Closed loop frequency response of the Vo / Erref with IMC controller The IMC controller introduces adequate bandwidth of around 1.5x106 rad/sec Fig. 7, which might result in adequate tracking for the solar irradiance variations. Moreover, the system behaves as low pass filter particularly for switching harmonics, Fig.7. An equivalent classical PI feedback controller CPI(s) of the IMC controller CIMC(s) could be obtained from, ( ) ( ) ( ) IMC PI IMC p C s C (s)= 1 C s G s− (16) The parameters of the PI controller, CPI(s) are given in Table2. TABLE 2 PARAMETERS OF THE PI CONTROLLER Proportional gain Kp 5 Integral gain Ki 200 IV. STATIC PERFORMANCE The static performance of the proposed system is estimated by computing the efficiency at different solar irradiance levels. The following assumptions are considered: • The losses in the input and output capacitors are ignored. • The different channels share the load equally, thus the efficiency is calculated per channel. • The input and out filters suppress the ripples in the input and output currents The efficiency of a channel is given by,
  • 10. International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 5, September – October (2013), © IAEME 29 ini pv_cu c_cond c_swit ind_cu ini P -P -P -P -P ξ= P (17) where Pini , Ppv_cu, Pind_cu, Pc_cond and Pc_swit are a channel input power, the copper losses in a PV generator and the output inductors, conduction and switching losses in a converter channel respectively The switch and the power diode in the converter channel were modeled during the on-state as a constant voltage element; thus the converter steady-state average conduction losses is given by, c_cond ce(sat) avg_Q on avg_DP =V I +V I (18) where Vce(sat), Iavg_Q, Von , and Iavg_Q are the on-state switch voltage drop, average switch current, diode on-state voltage drop and diode average current respectively. The switching frequency was determined as a compromise between the inductor size and switching losses; a value of 10 kHz was chosen. The switching losses of a switch in the three converter topologies are determined from switching frequency fs, turn on eon, and turn off eoff energies. The turn on eon and turn off eoff energy curves of the proposed switches could be considered to vary linearly with the switch current, thus the switch steady-state average switching losses can be approximated by, ( )c_swit s on off avg_QP =f E +E I (19) where Eon and Eoff are on-state constant and off-state constant respectively. Substitute (18) and (19) into (17) and simplify the efficiency is given by, ( )pv pv s ce(sat) on L s on off2 pv I1 I - - ( -1)- - D Dξ=1- V R V V R f E +E (20) Equation (20) indicates that the efficiency depends on the operating strategy of the converter channel. The converter drives the associated PV generator at MPP by modifying the duty cycle according to solar irradiance and temperature levels. The efficiency of the proposed cascaded PV system at different solar irradiation is illustrated in Fig. 8 0 100 200 300 400 500 600 700 800 900 1000 0.82 0.84 0.86 0.88 0.9 0.92 0.94 0.96 0.98 1 Solar irradiance Wm -2 Efficiency Fig. 8 Efficiency of cascaded PV system at different solar irradiation levels
  • 11. International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 5, September – October (2013), © IAEME 30 Fig. 8 shows that the efficiency of the proposed system increases with the solar irradiance. The system efficiency drops significantly below 100W/m2 insolation level. The graph illustrated in Fig. 8 shows the efficiency of the proposed system only when all modules are subjected to the same solar irradiance level. The efficiency of the proposed system is anticipated to be likely albeit lower than Fig. 8, due to the ignored losses. IV. DYAMIC RESPONSE In the following, the system performance for different irradiation levels is investigated. The convergence speed of MPPT and the effectiveness of the decoupling between the different channels are assessed by forcing step change in the solar irradiance in Figs. 9 and 10. This is realized by stepping the solar irradiance of generator 1 from 1000W/m2 to 100W/m2 at 0.1sec, 100W/m2 to 600W/m2 at 0.2sec, and 600W/m2 to 1000W/m2 at 0.3sec; the solar irradiance of generator 2 is stepped from 1000W/m2 to 500W/m2 at 0.1sec and from 500W/m2 to 1000W/m2 at 0.3sec. Generator 3 operates at 1000W/m2 over the time span under concern. 0.02 0.06 0.1 0.14 0.18 0.22 0.26 0.3 0.34 0.38 0 4 8 12 16 20 Time (sec) PVcurrents(A) 0.02 0.06 0.1 0.14 0.18 0.22 0.26 0.3 0.34 0.38 0 2000 4000 6200 Time (sec) PVpowers(W) Gen.#1 Gen.#2 Gen.#3 0.02 0.06 0.1 0.14 0.18 0.22 0.26 0.3 0.34 0.38 0 140 280 420 Time(sec) PVvoltages(V) Fig. 9. Top graph: voltages of PV generators, Middle graph: currents of PV generators, Bottom graph: powers of PV generators for 25o C and solar irradiance of generator 1 (blue) stepped from 1000W/m2 to 100W/m2 at 100msec, 100W/m2 to 600W/m2 at 200msec and from 600W/m2 to 1000W/m2 at 300msec; solar irradiance of generator 2(black) stepped from 1000W/m2 to 500W/m2 at 100msec, and 500W/m2 to 1000W/m2 at 300msec; solar irradiance of for generator 3(red) constant at 1000W/m2 Fig. 9 shows that MICC achieves fast tracking for MPP even under hypothetical conditions, as abrupt change for solar irradiance. Moreover, the controller achieves full decoupling between different channels. A channel responds only when its operating conditions change, and there is no response for conditions affecting other PV generators/buck converters, although they shire the same DC-link. The figure show also that the output currents/powers of the PV generators vary linearly with the solar insolation. This was predicted in Fig. 5, where static performance of a PV generator was computed and drawn. The voltage of the PV generators, is less affected by solar irradiance change, as shown in ref. [13].
  • 12. International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 5, September – October (2013), © IAEME 31 0.02 0.06 0.1 0.14 0.18 0.22 0.26 0.3 0.34 0.38 100 200 300 400 Time (sec) DC-linkvoltag(V) 0.02 0.06 0.1 0.14 0.18 0.22 0.26 0.3 0.34 0.38 0 10 20 30 40 50 60 70 Time (sec) Outputcurrent(A) 0.02 0.06 0.1 0.14 0.18 0.22 0.26 0.3 0.34 0.38 0 50 100 150 Time (sec) Averagevoltagesofoutputchannels Channel 1 Channel 2 Channel 3 Fig. 10. Top graph: DC-link voltage, Middle graph: output current, Bottom graph average values of channels’ voltages for channel 1 (blue) solar irradiance stepped from 1000W/m2 to 100W/m2 at 100msec, 100W/m2 to 600W/m2 at 200msec and from 600W/m2 to 1000W/m2 at 300msec; for channel 2 (black) solar irradiance stepped from 1000W/m2 to 500W/m2 at 100msec, and 500W/m2 to 1000W/m2 at 300msec; for channel 3 (red) solar irradiance constant at 1000W/m2 The output current of the system varies nearly linearly with solar irradiance, Fig. 10. The switched switching modulation strategy reduces the ripples in the output currents and the DC-link voltage. Equation (2) predicts that in a cascaded PV system when a generator/channel encounters shading, its output power/voltage drops and hence the DC-link voltage. The output voltage of the shaded channel undergoes voltage reduction, while unshaded channels experiences increase in their output voltages. Fig. 10 validates this conclusion. In this Figure, generators/channels 1 and 2 encounter shading starting from 100msec with different degrees of solar irradiances, while generator 3 is unshaded. Consequently the output voltages of channels 1 and 2 encounter reduction during the shading while the output voltage of unshaded channel 1 increases. IV. SYSTEM RESPONSE UNDER ABNORMAL CONDITIONS The reliability of the system is assessed by examining its performance under abnormal conditions. In the following, the system behavior under different fault scenarios is investigated. The faults affected cascaded PV system could in the PV generator and/or the DC-DC converter and the associated control circuits. The PV generators are subjected to variety of abnormal conditions such as shading, breakdown, and thermal runaway. Except the shading, the PV generators are less likely to develop abnormal conditions. The focus in this work is on the faults in half-bridge. Open and short circuit faults are the major faults that semiconductors in the half-bridge could develop. These faults could be physically developed or resulted due to mail function in the gating circuits. The half-bridge has two switches; each switch composed of a parallel transistor and diode. In the following analysis, the switch is considered as a unit. Thus the open/short circuit fault disables the whole switch, which is practically valid. A. Open-circuit fault If the top-switch in the converter develops an open circuit fault, the output current circulates through the freewheeling diode of the bottom switch. Accordingly, the current of the PV generator in the faulted channel drops to zero. Fig. 11 shows the system performance under such fault. In this Figure, PV generators 1&3 operate at 1000Wm-2 and 25o C, while generator 2 runs at 500Wm-2 and 25o C; whereas, the system
  • 13. International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 5, September – October (2013), © IAEME 32 runs under these conditions, switch in buck cell attached to PV generator 2 encounters an open- circuit fault. 0.1 0.11 0.12 0.13 0.14 0.15 0.16 0.17 0.18 0.19 0.2 0 100 200 300 400 500 Time(sec) DC-linkvoltage(V) 0.1 0.11 0.12 0.13 0.14 0.15 0.16 0.17 0.18 0.19 0.2 0 30 60 90 Time (sec) Loadcurrent(A) 0.1 0.11 0.12 0.13 0.14 0.15 0.16 0.17 0.18 0.19 0.2 0 4 8 12 16 20 Time (sec) PVcurrents(A) 0.1 0.11 0.12 0.13 0.14 0.15 0.16 0.17 0.18 0.19 0.2 0 2000 4000 6200 Time (sec) PVpowers(W) Chan./Gen.#1 Chan./Gen.#2 Chan./Gen.#3 Fig. 11. Top graph: DC-link voltage , Middle top graph: load current , Middle bottom graph: currents of PV generators, and Bottom graph: powers of PV generators for open circuit fault in the top switch of converter in channel 2 at 150msec, PV generators 1 (blue), 2 (black) and 3 (red) for 1000w/m2 solar irradiance and 25o C temperature The current and hence power of PV generator in the faulted channel ceases to zero immediately after the fault, Fig. 11. The output current and DC-link voltage drop slightly, which is attributed to the loss of the power of PV generator 2, bottom graph in Fig. 11. This scenario could be predicted by (2). The voltage of that PV generator in the faulty channel was found to rise to open- circuit voltage level. The sustained open-circuited switch has less damaging impact on the cascaded system; as the losses in PV generator in faulted channel(s) drop to zero. However, the system operates at reduced output power. Fig. 10 shows that the un-faulted channels still operate at MPP and are not affected by the fault. This reflects the advantage of the proposed MPPT technique in decoupling the system into totally independent channels. If the bottom switch encounters open-circuit, the load current has to circulate through the PV generator in the faulty channel. This may damage the generator and the top-switch, as the output current is usually greater than the generator short-circuit current. The remedy strategies for this fault are limited. The allowed option is to permanently open the top switch and disable the whole system. This is to protect the faulty channel from damage due to conducting the output current, which is much higher than the ratings of PV generator and solid-state devices. The open circuited bottom switch could be identified by monitoring the voltage drop of the top switch. If this voltage drop exceeds the value corresponding to the system operation at short circuit operating point, the controller should command the top switch to permanently be opened. B. Short circuit fault When a top switch in half-bridge develops short circuit, the captured PV power drops to zero. The PV generator in the faulted channel operates at short-circuit point, provided that the output current is greater than the short-circuit current of the PV generator Isc. For this case, the current in the bottom switch ID is given by, D o scI =I -I (21)
  • 14. International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 5, September – October (2013), © IAEME 33 The system behavior during short circuit fault in top switch in converter attached to PV generator 2 is shown in Fig. 12. Before the fault the three generators were operating at MPP corresponding to 1000W/m2 solar irradiance and 25o C temperature. 0.1 0.11 0.12 0.13 0.14 0.15 0.16 0.17 0.18 0.19 0.2 0 100 200 300 400 500 Time(sec) DC-linkvoltage(V) 0.1 0.11 0.12 0.13 0.14 0.15 0.16 0.17 0.18 0.19 0.2 0 30 60 90 Time (sec) Loadcurrent(A) 0.1 0.11 0.12 0.13 0.14 0.15 0.16 0.17 0.18 0.19 0.2 14 16 18 Time (sec) PVcurrents(A) 0.1 0.11 0.12 0.13 0.14 0.15 0.16 0.17 0.18 0.19 0.2 0 2000 4000 6200 Time (sec) PVpowers(W) Chan./Gen.#1 Chan./Gen.#2 Chan./Gen.#3 Fig. 12. Top graph: DC-link voltage , Middle top graph: load current , Middle bottom graph: currents of PV generators, and Bottom graph: powers of PV generators for short circuit fault in the top switch of converter in channel 2 at 150msec, PV generators 1 (blue), 2 (black) and 3 (red) for 1000w/m2 solar irradiance and 25o C temperature The operation of the PV generator in the faulted channel altered from MPP before the fault to short-circuit point instantaneously during/post fault, Fig. 12. Although the harvested PV power from the faulted channel is zero for open and short circuit faults; however, the sustained operation with short circuit fault stress PV generator more than that of open circuit fault, due to elevated ohmic losses. Fig. 12 shows that again the healthy channels in the proposed system still are running at MPP irrespective to the status of the faulty channel. The short circuit fault of the bottom switch is similarly to that of the top-switch. In both cases the captured PV power drops to zero. However for bottom switch short circuit failure, an extra degree of freedom is existed that the top switch could be permanently opened. This protects the corresponding PV generator from severe cupper losses, while allowing the cascaded system to continue functioning albeit at reduced power level. VI. CONCLUSION The operation of autonomous cascaded PV system under different operating scenarios was thoroughly studied; the following conclusions could be drawn: 1. The buck topology is the proper circuit for series operation of PV generators. 2. The boost topology may have a satisfactory performance for parallel connection of PV generators. However, for series connection of PV generators, the boost topology fails to maintain the decoupling between the channels under abnormal conditions such as partial shading. 3. The series connection of PV generators has more advantages than the parallel one such as: higher efficiency and elimination of second DC/DC conversion
  • 15. International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 5, September – October (2013), © IAEME 34 4. The half-bridge buck converter is preferred in cascaded PV system due to its availability and bi-directional power flow capability, which allows interfacing the batteries/super-capacitors to the cascaded system. 5. Employing shift switching techniques reduces the ripples in the output/input waveforms without comprising the efficiency, weight or volumetric dimension. 6. The diode in the buck topology provides adequate freewheeling path for the output current in case of the corresponding PV generator is partially/fully shaded. 7. Forcing the error between the incremental and instantaneous inductance to be zero, allows faster tracking for MPP. 8. The IMC controller has the merits of simplicity, time-delay compensation and adequate tracking for the reference. 9. The short-circuit switch fault encounters excessive copper losses inside the PV generator. REFERENCES [1] J. T. Bialasiewicz, "Power-Electronics Systems for the Grid Integration of Renewable Energy Sources: A Survey" IEEE Transactions on industrial Electronics, Vol. 53, pp. 1002-1016, August 2006. [2] J. T. Bialasiewicz, "Renewable Energy System with Photovoltaic Power Generators: Operation and Modeling," IEEE Transactions on industrial Electronics, Vol. 55, pp. 2752- 2758, July 2008. [3] E. Endo and K. Kurokawa, "Sizing procedure for photovoltaic systems " in IEEE First World Conference on Photovoltaic Energy Conversion, 1994, pp. 1196 - 1199. [4] A. I. Bratcu; I. Munteanu; S. Bacha; D. Picaul and B. Raison" Cascaded DC-DC Converter Photovoltaic Systems: Power Optimization Issues" IEEE Transactions on Industrial Electronics,Vol. 19, pp. 120-128, 2010. [5] M. Valan Rajkumar and P.S. Manoharan “FPGA based multilevel cascaded inverters with SVPWM algorithm for photovoltaic system” Solar Energy, Vol. 87, pp. 229-245, 2013. [6] Y. Zhang, J. T. Sun and Y. F. Wang “Hybrid Boost Three-Level DC–DC Converter with High Voltage Gain for Photovoltaic Generation Systems” IEEE Transactions on Power Electronics, Vol. 28, issue 8. pp. 3659 – 3664, 2013. [7] J. Ferreira “The Multilevel Modular DC Converter” IEEE Transactions on Power Electronics, Vol. 1, issue 99, pp. 1-5, 2013. [8] R. Geofrey; P. Walker and P. C. Serina, "Cascaded DC-DC Converter Connection of Photovoltiac Modules," IEEE Transactions on Power Electronics, Vol. 19, pp. 1130-1139, 2004. [9] W. Chen; X. Ruan; H. Yan and C. K. Tse "DC/DC Conversion Systems Consisting of Multiple Converter Modules: Stability, Control and Experimental Verifications" IEEE Transactions on Power Electronics, Vol. 24, pp. 1463-1474, 2005. [10] D. Montesinos; O. Gomis; A. Sudria and A. Rufer" Multilevel DC/DC converter design for mobile applications" PCIM 2010, pp. 899-903, 4-6 May 2010. [11] D. Montesinos; O. Gomis; A. Sudria and A. Rufer " Control of a Multilevel modular DC/DC converter design for mobile applications" PCIM 2010, pp. 107-110, 4-6 May 2010. [12] T. Esram and P. L. Chapman " Comparison of Photovoltiac Array Maximum Power Point Tracking Techniques" IEEE Transactions on Energy Conversion, Vol. 22, pp.439-449, 2007. [13] A. A. hafez, "simple and robust Maximum Power Point Tracking Algorithm for a solar cell," in World Congress on Electronics and Electrical Engineering (WCEEENG'10). 2010, pp. 240-245, April 2010.
  • 16. International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 5, September – October (2013), © IAEME 35 [14] KC200GT High Efficiency Multicrystal Photovoltaic Module Datasheet Kyocera: http://www.kyocera.com.sg/products/solar/ pdf/kc200gt.pdf., 2011 [15] M. Villalva; J. Gazoli and E. R. Filho, "Comprehensive Approach to Modeling and Simulation of Photovoltaic Arrays," IEEE Transactions on Power Electronics, Vol. 24, pp. 1198-1208, 2009. [16] D. Hansen; P. Sørensen; L. Hansen and H. Bindner, “Models for a Stand-Alone PV System”, Risø-R-1219(EN) / SEC-R-12, 2000 [17] R. S. Burns” Advanced Control Engineering “1st edition, Butterworth-Heinemann, Oxford, UK, 2001. [18] Sahaj Saxena and Yogesh V Hote” Advances in Internal Model Control Technique: A Review and Future Prospects” IETE Technical Review, Vol. 29, issue 6, pp. 461-472, 2012. [19] M.Sujith, R.Mohan and P.Sundravadivel, “Simulation Analysis of 100kw Integrated Segmented Energy Storage for Grid Connected Pv System”, International Journal of Electrical Engineering & Technology (IJEET), Volume 3, Issue 2, 2012, pp. 164 - 173, ISSN Print : 0976-6545, ISSN Online: 0976-6553. [20] Rajasekharachari K, K.Shalini, Kumar .K and S.R.Divya, “Advanced Five Level - Five Phase Cascaded Multilevel Inverter with SVPWM Algorithm”, International Journal of Electrical Engineering & Technology (IJEET), Volume 4, Issue 4, 2013, pp. 144 - 158, ISSN Print: 0976-6545, ISSN Online: 0976-6553. [21] M.Saisesha, V.S.N.Narasimharaju, R.Madhu Sudanarao and M.Balaji, “Control of Power Inverters in Renewable Energy and Smart Grid Integration”, International Journal of Electrical Engineering & Technology (IJEET), Volume 4, Issue 1, 2013, pp. 200 - 207, ISSN Print: 0976-6545, ISSN Online: 0976-6553.