SlideShare una empresa de Scribd logo
1 de 10
Descargar para leer sin conexión
Prof S S Jahagirdar, NKOCET

AIR POLLUTION
AND CONTROL
(Elective-I)
Problems set for
UNIT-IV
AIR POLLUTION METEOROLOGY

Page | 1
BE (Civil)

L-

ROLL NO-

Air pollution (Elective -I)
Unit-IV
Stability conditions (Temperature gradient) Problems
1.

On the basis of temperature gradient in the situation described below classify the degree of
stability of atmosphere.
i.
ii.

Temp at ground 350C and temp at 650 m height is 220 C

iii.

Temp at ground 250C and temp at 700 m height is 280 C

iv.

2.

Temp at ground 340C and temp at 500 m height is 400 C

Temp at ground 250C and temp at 200 m height is 50 C

Temperature at ground level is 30OC. Find the atmospheric stability condition in each
of the following cases.
Case

Temp. (OC)

I

700

10

II

500

34

III

1000

25

IV

3.

Altitude (m)

500

20

Determine whether the atmosphere is unstable, neutral or stable for the following case.
Initial Temperature

30.2 oC

Final Temperature

- 58.5 oC

Initial Height

221 m

Final Height

23214 m
BE (Civil)

L-

ROLL NO-

Air pollution (Elective -I)
Unit-IV
Finding Wind speed at higher altitudes Problems
1.

The wind speed at 10 m altitude is 5m/s. Find the wind speed at 250 m altitude for
the following stability conditions.
i.
ii.

Zero or small lapse rate

iii.

Moderate inversion

iv.
2.

Large lapse rate

Large inversion

Wind speed at 10 m altitude is 2m/s. Find the wind speed at 200 m altitude for
following cases
i.
ii.

Zero lapse rate

iii.

Moderate inversion

iv.
3.

Large lapse rate

Large inversion

The ground level wind velocity at 10 m elevation is 5.2 m/sec in a city. What would
you estimate the velocity to be at 125m elevation in moderately stable atmosphere?
BE (Civil)

L-

ROLL NO-

Air pollution (Elective -I)
Unit-IV
Maximum Mixing Depth (MMD) Problems
1.

At a given location the ground Environmental air temperature is 180 C, while normal
maximum surface temperature for the month is known to be 300 C. At an elevation of
700 m the temperature of the atmosphere measured is a) 150 C and b) 200 C. What is
maximum mixing depth in meters for two cases?

2.

Air parcel temp at ground level is 280C. The environmental temperature at ground
level is 300 and at 500 m is 27.5 0C. Determine the MMD

3.

A rising parcel of dry air has a temp of 300 C at sea level. Assuming DALR of 10C/100m, determine MMD if environmental temperature temp at sea level is 150C
and ELR is +10C/100 m

4.

In a given situation ground level temperature is 180C, while normal maximum surface
temp for that month is a) 26 0C and b) 240C. At an elevation of 300 m the temperature
is found to be 210C. What is MMD in metres for both the cases?

5.

A rising parcel of dry air has a temp of 350 C at sea level. Assuming DALR of 10C/100m, determine MMD if environmental temperature temp at sea level is 150C
and ELR is +10C/100 m

6.

Determine the maximum mixing depth if flue gas temperature is 30oC, when:
i)

Average ground temperature is 20 oC and temperature at elevation of 600 m
is 30oC

ii)

Average ground temperature is 25 oC and temperature at elevation of 500 m
is 20oC

Assume DALR= -9.8 oC/1000 m.
7.

Calculate the maximum mixing height from the following early morning temperature
data given below:
Height (m)

0

250 350 450 550 650

Temperature (oC) 9.5 12.2 15.1 15.6 16.2 16.5

The maximum surface
temperature for the day was
15oC.
BE (Civil)

L-

ROLL NO-

Air pollution (Elective -I)
Unit-IV
Minimum (safe) Stack height determination Problems
1.

A factory uses 1.5 ML of fuel oil per month. The exhaust gases from factory
contain the following quantities of pollutant per ML per year:
i.

Particulate matter = 5 t/yr

ii.

Sulphur dioxide= 21 t/yr

Determine the safe height of chimney required for safe dispersion of pollutants.
2.

A factory uses 2 ML of fuel oil per month. The exhaust gases from factory contain
the following quantities of pollutant per ML per year:
i.

Particulate matter = 5 t/yr

ii.

Sulphur dioxide= 21 t/yr

iii.

Nitrogen dioxide= 4 t/yr

Determine the safe height of chimney required for safe dispersion of pollutants.
BE (Civil)

L-

ROLL NO-

Air pollution (Elective -I)
Unit-IV
Plume rise Problems
1.

The heat emission rate associated with a stack gas is 4800 KJ/sec, the wind and
stack gas speeds are 5 m/s and 15 m/s respectively and the inside dia of stack top is
2m. Estimate the plume rise by
i.
ii.

Concave

iii.
2.

Carson Mosses

Holland’s formula

The wind and stack gas speeds are 3 m/s and 6 m/s respectively and stack dia is 2m.
The atmospheric stability condition is neutral with a temp of 3000K and the stack gas
temp is 4400K. Estimate plume rise in m by Brigg’s equation and TVA model
equation.

3.

Determine the effective stack height given by following data
i.
ii.

Inner dia of stack = 1.07 m

iii.

Air temp =130C

iv.

Barometric pressure = 1000 mbar

v.

Stack gas velocity = 9.14 m/s

vi.

Stack gas temperature = 1490 C

vii.
4.

Physical stack height= 203 m

Wind velocity at stack top = 5 m/s

Determine the effective stack height given by following data
i.

Physical stack height= 180 m

ii.

Inner dia of stack = 0.95 m

iii.

Air temp =20 0C

iv.

Barometric pressure = 1000 mbar

v.

Stack gas velocity =11.12 m/s

vi.

Stack gas temperature = 1600 C

vii.

Wind velocity at stack top = 2.75 m/s
BE (Civil)

L-

ROLL NO-

Air pollution (Elective -I)
Unit-IV
Emission rate Problems
1.

A power plant burns coal at the rate of 500 kg/hr. It consists of ash 30 %, Sulphur -3
% and carbon 40 %. Determine the emission rates of SPM and SO2 in mg/m3 and
gm/sec.

2.

A power plant burns coal at 500 kg/hr per MWe. Capacity of power plant is 500
MWe.
Coal contains 30 % ash and 1 % sulphur and 40 % carbon.
Determine
i)
ii)

SO2 and CO2 emission

iii)
3.

SPM emission

Quantity of air required for combustion.

A power plant burns coal at the rate of 500 kg/min. It consists of ash 30 %, Sulphur 1 % and carbon 40 %. Determine the emission rates of SPM, CO2 and SO2 in mg/m3
and gm/sec.

4.

A power plant burns 25 tonnes of coal/day having 30% ash. Determine the efficiency
of particulate matter control equipment to maintain SPM level below 150
microgram/m3. If stack dia is 2.5 m and flue gas velocity is 9 m/s.

5.

A power plant uses 500 kg of coal/hr. Coal contains 40% ash and 2% sulphur. Stack
diameter at exit is 2 m and the stack gas velocity is 20 m/s and temp is 1000C.
Calculate
i.

SPM concentration in microgram/m3

ii.

SO2 emission in ppm

iii.

How much efficiency should be kept for the dust control equipment to
meet emission standard of 150 micrograms/m3
BE (Civil)

L-

ROLL NO-

Air pollution (Elective -I)
Unit-IV
Gaussian dispersion model Problems
1.

A thermal power plant burns coal at the rate of 10 t/hr and discharges the fuel gas
though a stack having effective height of 90 m. The coal has sulphur content of 4%.
The wind speed at stack top is 6m/s. The atmospheric stability class is ‘C’. For this
class at downwind distance of 2000m the constants σy and σz are 200 and 120
respectively. Find the concentration of sulphur dioxide at ground level at 2000m
downwind and 500m crosswind distance.

2.

A power plant burns 5 tons of coal per hour with 4% sulphur content, discharges the
product through a stack with 75 m effective height. The velocity of wind at top of
stack is 6 m/s and atmospheric stability class is ‘C’. Determine the maximum ground
level concentration of SO2. Also determine the ground level concentrations at 3.0 km
downwind and cross wind distance of 0.4 m on the either sides of centreline for ‘C’
class stability on the either side of centreline
Distance in m

σz in m

850

88

53

3000
3.

σy in m

280

170

A coal fired power plant emits SO2 at a rate of 200 g/s. If effective stack height is 60
m determine the ground level concentration downwind if wind speed at 60 m height
is 4 m/s and stability class prevailing is ‘B’
Distance

0.5 km

1 km

2 km

3 km

σy in m

70

160

310

420

σz in m

50

140

360

700

Plot concentration versus distance on log x log scale.
4.

A coal fired power plant burns 20,000 tonnes of coal per day. Coal contains 3%
sulphur, physical stack height=150 m, stack dia at top 4m, Stack gas velocity= 20
m/s and temperature is 1400 C. Surrounding air temperature is 1200 C and pressure
1000 mbar. Wind speed at 150 m = 6 m/s, Env lapse rate = +10 C/100 m.
Determine
1. Plume rise by Brigg’s formula
2. SO2 concentration at 1000 m downwind from stack (centreline) for ‘B’
BE (Civil)

L-

ROLL NO-

class stability, if σy in m= 170 and σz in m= 140 at 1000 m.
5.

A coal fired power plant emits SO2 at a rate of 100 g/s. If effective stack height is
100 m determine the ground level concentration downwind if wind speed at 100 m
height is 4 m/s and stability class prevailing is ‘B’
Distance

0.5 km

1 km

2 km

3 km

σy in m

70

160

310

420

σz in m

50

140

360

700

Plot concentration versus distance on log x log scale.
6.

A coal fired power plant emits SO2 at a rate of 300 g/s. If effective stack height is
150 m determine the ground level concentration downwind if wind speed at 10 m
height is 4 m/s and stability class prevailing is ‘B’
Distance

1 km

2 km

3 km

σy in m

70

160

310

420

σz in m
7.

0.5 km

50

140

360

700

SO2 is emitted at a rate of 0.9 kg/sec from a stack with effective height of 220 m.
The wind speed at that height is 5 m/sec and stability category is ‘B’. Determine the
downwind centre line concentration in micrograms/m3 at ground level distance from
stack of 1) 0.5 km 2) 1km,3) 2km and 4) 3km. Plot C versus log of distance curve
Distance

1 km

2 km

3 km

σy in m

110

160

300

450

σz in m
8.

0.5 km

65

120

220

310

A coal fired power plant burns coal at the rate of 500 kg/hr. Coal contains 1%
sulphur and

30% ash, physical stack height=100 with plume rise of 50 m. Wind

speed at stack top is 5 m/sec.
Determine
1. Determine SO2 and SPM emission rate.
2. Also determine GLC of SO2 and SPM at 1000m from stack for ‘B’ class
stability, if σy in m= 60 and σz in m= 25 at 1000 m.
Assume all the other data.
9.

An industrial boiler is burning at 12 tons (10.9 mton) of 2.5% sulfur coal/hr with an
emission rate of 151 g/s. The following conditions exist: H = 120 m, u = 2 m/s, y =
0. It is one hour before sunrise, and the sky is clear. Determine downwind ground
level concentration at 10 km.
BE (Civil)
10.

L-

ROLL NO-

If emissions are from a ground level source with H = 0, u = 4 m/s, Q = 100 g/s, and
the stability class = B, what is downwind concentration at 200 m?

11.

A stack in an urban area is emitting 80 g/s of NO. It has an effective stack height of
100 m. The wind speed is 4 m/s at 10 m. It is a clear summer day with the sun
nearly overhead.
Estimate the ground level concentration at:a) 2 km downwind on the centerline and
b) 2 km downwind, 0.1 km off the centerline.

Más contenido relacionado

La actualidad más candente

Water treatment-lecture-4-eenv
Water treatment-lecture-4-eenvWater treatment-lecture-4-eenv
Water treatment-lecture-4-eenvusman1017
 
Design criteria for waste water treatment
Design criteria for waste water treatmentDesign criteria for waste water treatment
Design criteria for waste water treatmentBibhabasu Mohanty
 
Lab 4 alkalinity –acidity and determination of alkalinity in water
Lab 4 alkalinity –acidity and determination of alkalinity in waterLab 4 alkalinity –acidity and determination of alkalinity in water
Lab 4 alkalinity –acidity and determination of alkalinity in waterAnas Maghayreh
 
Trays in distillation column
Trays in distillation columnTrays in distillation column
Trays in distillation columnShaukat Ali
 
Saybolt viscosity
Saybolt viscositySaybolt viscosity
Saybolt viscosityTaha Samir
 
Introduction To Environmental Engineering 4th Edition Davis Solutions Manual
Introduction To Environmental Engineering 4th Edition Davis Solutions ManualIntroduction To Environmental Engineering 4th Edition Davis Solutions Manual
Introduction To Environmental Engineering 4th Edition Davis Solutions Manualmafijimyko
 
Perry’s Chemical Engineers’ Handbook 7ma Ed Chap 12
Perry’s Chemical Engineers’ Handbook  7ma Ed Chap 12Perry’s Chemical Engineers’ Handbook  7ma Ed Chap 12
Perry’s Chemical Engineers’ Handbook 7ma Ed Chap 12Grey Enterprise Holdings, Inc.
 
Gaussian Plume Dispersion Model
Gaussian Plume Dispersion ModelGaussian Plume Dispersion Model
Gaussian Plume Dispersion ModelKulvendra Patel
 
11 air pollution dispersion
11 air pollution dispersion11 air pollution dispersion
11 air pollution dispersionGaurav Pahuja
 
EXH2200 Cooling Tower Design Guidelines.pdf
EXH2200 Cooling Tower Design Guidelines.pdfEXH2200 Cooling Tower Design Guidelines.pdf
EXH2200 Cooling Tower Design Guidelines.pdfZeeshanAlam90
 
Meteorological Factors Influencing Air Pollution And Atmospheric Stability ...
Meteorological Factors Influencing Air Pollution  And  Atmospheric Stability ...Meteorological Factors Influencing Air Pollution  And  Atmospheric Stability ...
Meteorological Factors Influencing Air Pollution And Atmospheric Stability ...NiranjanHiremath12
 
Treatment of crude oils
Treatment of crude oilsTreatment of crude oils
Treatment of crude oilsKarnav Rana
 
Unit 3 control of particulate contaminants
Unit 3 control of particulate contaminantsUnit 3 control of particulate contaminants
Unit 3 control of particulate contaminantsChockalingam T
 

La actualidad más candente (20)

Water treatment-lecture-4-eenv
Water treatment-lecture-4-eenvWater treatment-lecture-4-eenv
Water treatment-lecture-4-eenv
 
Design criteria for waste water treatment
Design criteria for waste water treatmentDesign criteria for waste water treatment
Design criteria for waste water treatment
 
Lab 4 alkalinity –acidity and determination of alkalinity in water
Lab 4 alkalinity –acidity and determination of alkalinity in waterLab 4 alkalinity –acidity and determination of alkalinity in water
Lab 4 alkalinity –acidity and determination of alkalinity in water
 
L 5 characterization part-ii
L 5 characterization part-iiL 5 characterization part-ii
L 5 characterization part-ii
 
Trays in distillation column
Trays in distillation columnTrays in distillation column
Trays in distillation column
 
AIR POLLUTION CONTROL L 19
AIR POLLUTION CONTROL  L 19AIR POLLUTION CONTROL  L 19
AIR POLLUTION CONTROL L 19
 
Saybolt viscosity
Saybolt viscositySaybolt viscosity
Saybolt viscosity
 
Introduction To Environmental Engineering 4th Edition Davis Solutions Manual
Introduction To Environmental Engineering 4th Edition Davis Solutions ManualIntroduction To Environmental Engineering 4th Edition Davis Solutions Manual
Introduction To Environmental Engineering 4th Edition Davis Solutions Manual
 
ETS Trip.pptx
ETS Trip.pptxETS Trip.pptx
ETS Trip.pptx
 
Waster water treatment
Waster water treatmentWaster water treatment
Waster water treatment
 
01 kern's method.
01 kern's method.01 kern's method.
01 kern's method.
 
Perry’s Chemical Engineers’ Handbook 7ma Ed Chap 12
Perry’s Chemical Engineers’ Handbook  7ma Ed Chap 12Perry’s Chemical Engineers’ Handbook  7ma Ed Chap 12
Perry’s Chemical Engineers’ Handbook 7ma Ed Chap 12
 
L 11 screen chamber
L 11 screen chamberL 11 screen chamber
L 11 screen chamber
 
Gaussian Plume Dispersion Model
Gaussian Plume Dispersion ModelGaussian Plume Dispersion Model
Gaussian Plume Dispersion Model
 
11 air pollution dispersion
11 air pollution dispersion11 air pollution dispersion
11 air pollution dispersion
 
EXH2200 Cooling Tower Design Guidelines.pdf
EXH2200 Cooling Tower Design Guidelines.pdfEXH2200 Cooling Tower Design Guidelines.pdf
EXH2200 Cooling Tower Design Guidelines.pdf
 
Meteorological Factors Influencing Air Pollution And Atmospheric Stability ...
Meteorological Factors Influencing Air Pollution  And  Atmospheric Stability ...Meteorological Factors Influencing Air Pollution  And  Atmospheric Stability ...
Meteorological Factors Influencing Air Pollution And Atmospheric Stability ...
 
Treatment of crude oils
Treatment of crude oilsTreatment of crude oils
Treatment of crude oils
 
Unit 3 control of particulate contaminants
Unit 3 control of particulate contaminantsUnit 3 control of particulate contaminants
Unit 3 control of particulate contaminants
 
Air Pollution
Air Pollution Air Pollution
Air Pollution
 

Destacado

Determining the Best Heat Recovery System to Maximize Boiler Efficiency
Determining the Best Heat Recovery System to Maximize Boiler EfficiencyDetermining the Best Heat Recovery System to Maximize Boiler Efficiency
Determining the Best Heat Recovery System to Maximize Boiler EfficiencyCleaver-Brooks
 
applications overview
applications overviewapplications overview
applications overviewMark Jutila
 
1.4 material and energy balance
1.4 material  and energy balance1.4 material  and energy balance
1.4 material and energy balancemichjosh
 

Destacado (6)

Determining the Best Heat Recovery System to Maximize Boiler Efficiency
Determining the Best Heat Recovery System to Maximize Boiler EfficiencyDetermining the Best Heat Recovery System to Maximize Boiler Efficiency
Determining the Best Heat Recovery System to Maximize Boiler Efficiency
 
Efficient steam systems - Generation to WHR
Efficient steam systems - Generation to WHREfficient steam systems - Generation to WHR
Efficient steam systems - Generation to WHR
 
Patel dhaval
Patel dhaval Patel dhaval
Patel dhaval
 
applications overview
applications overviewapplications overview
applications overview
 
F05732228
F05732228F05732228
F05732228
 
1.4 material and energy balance
1.4 material  and energy balance1.4 material  and energy balance
1.4 material and energy balance
 

Similar a AIR POLLUTION CONTROL Unit iv problem set

AIR POLLUTION CONTROL Unit ii problem set
AIR POLLUTION CONTROL  Unit ii problem setAIR POLLUTION CONTROL  Unit ii problem set
AIR POLLUTION CONTROL Unit ii problem setDr. shrikant jahagirdar
 
2. 2009 oxid 20 cr pm 800 900c 100hr
2. 2009 oxid 20 cr pm 800 900c 100hr2. 2009 oxid 20 cr pm 800 900c 100hr
2. 2009 oxid 20 cr pm 800 900c 100hrLamiaaZaky1
 
3_Air___Noise_pollution.pptx
3_Air___Noise_pollution.pptx3_Air___Noise_pollution.pptx
3_Air___Noise_pollution.pptxRebelBaKa
 
Chapter 1
Chapter 1Chapter 1
Chapter 1ECRD IN
 
Fullerenes Synthesis Using Fabricated Arc Discharge System with Relatively La...
Fullerenes Synthesis Using Fabricated Arc Discharge System with Relatively La...Fullerenes Synthesis Using Fabricated Arc Discharge System with Relatively La...
Fullerenes Synthesis Using Fabricated Arc Discharge System with Relatively La...iosrjce
 
Petrographic investigation to assess condition of concrete exposed to fire
Petrographic investigation to assess condition of concrete exposed to firePetrographic investigation to assess condition of concrete exposed to fire
Petrographic investigation to assess condition of concrete exposed to fireIRJET Journal
 
Chemistry zimsec chapter 13 nitrogen and sulfur
Chemistry zimsec chapter 13  nitrogen and sulfurChemistry zimsec chapter 13  nitrogen and sulfur
Chemistry zimsec chapter 13 nitrogen and sulfuralproelearning
 
Air pollution, sources and characteristics
Air pollution, sources and characteristicsAir pollution, sources and characteristics
Air pollution, sources and characteristicsECRD2015
 
Chapter 2
Chapter 2Chapter 2
Chapter 2ECRD IN
 
Air Pollution, Sources and Characteristics
Air Pollution, Sources and CharacteristicsAir Pollution, Sources and Characteristics
Air Pollution, Sources and CharacteristicsECRD IN
 
Fire Resistance of Materials & Structures - Assessment of Structural in a Fur...
Fire Resistance of Materials & Structures - Assessment of Structural in a Fur...Fire Resistance of Materials & Structures - Assessment of Structural in a Fur...
Fire Resistance of Materials & Structures - Assessment of Structural in a Fur...Arshia Mousavi
 
INFLUENCE OF FIRING ATMOSPHERES AND GAMMA RADIATION ON V-I CHARACTERISTIC OF ...
INFLUENCE OF FIRING ATMOSPHERES AND GAMMA RADIATION ON V-I CHARACTERISTIC OF ...INFLUENCE OF FIRING ATMOSPHERES AND GAMMA RADIATION ON V-I CHARACTERISTIC OF ...
INFLUENCE OF FIRING ATMOSPHERES AND GAMMA RADIATION ON V-I CHARACTERISTIC OF ...Hety Puspitasari
 
Firefighting equipment
Firefighting equipmentFirefighting equipment
Firefighting equipmentrao56745
 
Feasibility Study of Synthesis of Nanostructured Aluminum Nitride Through Sol...
Feasibility Study of Synthesis of Nanostructured Aluminum Nitride Through Sol...Feasibility Study of Synthesis of Nanostructured Aluminum Nitride Through Sol...
Feasibility Study of Synthesis of Nanostructured Aluminum Nitride Through Sol...IJERA Editor
 
Fianl PPT Nanotechnology.ppt
Fianl PPT Nanotechnology.pptFianl PPT Nanotechnology.ppt
Fianl PPT Nanotechnology.pptResearchSolutions
 
Mattson-RTP-3000.pdf
Mattson-RTP-3000.pdfMattson-RTP-3000.pdf
Mattson-RTP-3000.pdfACAllen2
 

Similar a AIR POLLUTION CONTROL Unit iv problem set (20)

AIR POLLUTION CONTROL Unit ii problem set
AIR POLLUTION CONTROL  Unit ii problem setAIR POLLUTION CONTROL  Unit ii problem set
AIR POLLUTION CONTROL Unit ii problem set
 
CLC project
CLC projectCLC project
CLC project
 
2. 2009 oxid 20 cr pm 800 900c 100hr
2. 2009 oxid 20 cr pm 800 900c 100hr2. 2009 oxid 20 cr pm 800 900c 100hr
2. 2009 oxid 20 cr pm 800 900c 100hr
 
3_Air___Noise_pollution.pptx
3_Air___Noise_pollution.pptx3_Air___Noise_pollution.pptx
3_Air___Noise_pollution.pptx
 
Industrial air pollution
Industrial air pollutionIndustrial air pollution
Industrial air pollution
 
Unit vii problem set
Unit vii problem setUnit vii problem set
Unit vii problem set
 
Chapter 1
Chapter 1Chapter 1
Chapter 1
 
Fullerenes Synthesis Using Fabricated Arc Discharge System with Relatively La...
Fullerenes Synthesis Using Fabricated Arc Discharge System with Relatively La...Fullerenes Synthesis Using Fabricated Arc Discharge System with Relatively La...
Fullerenes Synthesis Using Fabricated Arc Discharge System with Relatively La...
 
Petrographic investigation to assess condition of concrete exposed to fire
Petrographic investigation to assess condition of concrete exposed to firePetrographic investigation to assess condition of concrete exposed to fire
Petrographic investigation to assess condition of concrete exposed to fire
 
Assignment-1.pdf
Assignment-1.pdfAssignment-1.pdf
Assignment-1.pdf
 
Chemistry zimsec chapter 13 nitrogen and sulfur
Chemistry zimsec chapter 13  nitrogen and sulfurChemistry zimsec chapter 13  nitrogen and sulfur
Chemistry zimsec chapter 13 nitrogen and sulfur
 
Air pollution, sources and characteristics
Air pollution, sources and characteristicsAir pollution, sources and characteristics
Air pollution, sources and characteristics
 
Chapter 2
Chapter 2Chapter 2
Chapter 2
 
Air Pollution, Sources and Characteristics
Air Pollution, Sources and CharacteristicsAir Pollution, Sources and Characteristics
Air Pollution, Sources and Characteristics
 
Fire Resistance of Materials & Structures - Assessment of Structural in a Fur...
Fire Resistance of Materials & Structures - Assessment of Structural in a Fur...Fire Resistance of Materials & Structures - Assessment of Structural in a Fur...
Fire Resistance of Materials & Structures - Assessment of Structural in a Fur...
 
INFLUENCE OF FIRING ATMOSPHERES AND GAMMA RADIATION ON V-I CHARACTERISTIC OF ...
INFLUENCE OF FIRING ATMOSPHERES AND GAMMA RADIATION ON V-I CHARACTERISTIC OF ...INFLUENCE OF FIRING ATMOSPHERES AND GAMMA RADIATION ON V-I CHARACTERISTIC OF ...
INFLUENCE OF FIRING ATMOSPHERES AND GAMMA RADIATION ON V-I CHARACTERISTIC OF ...
 
Firefighting equipment
Firefighting equipmentFirefighting equipment
Firefighting equipment
 
Feasibility Study of Synthesis of Nanostructured Aluminum Nitride Through Sol...
Feasibility Study of Synthesis of Nanostructured Aluminum Nitride Through Sol...Feasibility Study of Synthesis of Nanostructured Aluminum Nitride Through Sol...
Feasibility Study of Synthesis of Nanostructured Aluminum Nitride Through Sol...
 
Fianl PPT Nanotechnology.ppt
Fianl PPT Nanotechnology.pptFianl PPT Nanotechnology.ppt
Fianl PPT Nanotechnology.ppt
 
Mattson-RTP-3000.pdf
Mattson-RTP-3000.pdfMattson-RTP-3000.pdf
Mattson-RTP-3000.pdf
 

Más de Dr. shrikant jahagirdar (20)

Indoor Air Pollution .......................
Indoor Air Pollution .......................Indoor Air Pollution .......................
Indoor Air Pollution .......................
 
06 Filtration.ppt
06 Filtration.ppt06 Filtration.ppt
06 Filtration.ppt
 
Oxidation pond problem
Oxidation pond problemOxidation pond problem
Oxidation pond problem
 
Module v Environmental Sanitation
Module v Environmental SanitationModule v Environmental Sanitation
Module v Environmental Sanitation
 
Module VI Rural Sanitation
Module VI Rural SanitationModule VI Rural Sanitation
Module VI Rural Sanitation
 
Module IV Wastewater treatment methods
Module IV Wastewater treatment methodsModule IV Wastewater treatment methods
Module IV Wastewater treatment methods
 
Hw2 do sag curve
Hw2 do sag curveHw2 do sag curve
Hw2 do sag curve
 
Do sag problems
Do sag problemsDo sag problems
Do sag problems
 
Do sag curve
Do sag curveDo sag curve
Do sag curve
 
Module iii
Module iiiModule iii
Module iii
 
Septic tank
Septic tankSeptic tank
Septic tank
 
Unit viii
Unit viiiUnit viii
Unit viii
 
Unit vii
Unit viiUnit vii
Unit vii
 
L tannery industry
L tannery industryL tannery industry
L tannery industry
 
L sugar industry
L sugar industryL sugar industry
L sugar industry
 
L distillery industry
L distillery industryL distillery industry
L distillery industry
 
L dairy industry
L dairy industryL dairy industry
L dairy industry
 
L 31 Water Pollution act and other topics
L 31 Water Pollution act and other topicsL 31 Water Pollution act and other topics
L 31 Water Pollution act and other topics
 
L 30 fertilizer industry
L 30 fertilizer industryL 30 fertilizer industry
L 30 fertilizer industry
 
L 29 steel industry
L 29 steel industryL 29 steel industry
L 29 steel industry
 

Último

Manulife - Insurer Innovation Award 2024
Manulife - Insurer Innovation Award 2024Manulife - Insurer Innovation Award 2024
Manulife - Insurer Innovation Award 2024The Digital Insurer
 
Why Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire businessWhy Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire businesspanagenda
 
TrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
TrustArc Webinar - Stay Ahead of US State Data Privacy Law DevelopmentsTrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
TrustArc Webinar - Stay Ahead of US State Data Privacy Law DevelopmentsTrustArc
 
Exploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone ProcessorsExploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone Processorsdebabhi2
 
Artificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : UncertaintyArtificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : UncertaintyKhushali Kathiriya
 
Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024The Digital Insurer
 
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024The Digital Insurer
 
HTML Injection Attacks: Impact and Mitigation Strategies
HTML Injection Attacks: Impact and Mitigation StrategiesHTML Injection Attacks: Impact and Mitigation Strategies
HTML Injection Attacks: Impact and Mitigation StrategiesBoston Institute of Analytics
 
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...DianaGray10
 
Workshop - Best of Both Worlds_ Combine KG and Vector search for enhanced R...
Workshop - Best of Both Worlds_ Combine  KG and Vector search for  enhanced R...Workshop - Best of Both Worlds_ Combine  KG and Vector search for  enhanced R...
Workshop - Best of Both Worlds_ Combine KG and Vector search for enhanced R...Neo4j
 
Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024The Digital Insurer
 
Scaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationScaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationRadu Cotescu
 
🐬 The future of MySQL is Postgres 🐘
🐬  The future of MySQL is Postgres   🐘🐬  The future of MySQL is Postgres   🐘
🐬 The future of MySQL is Postgres 🐘RTylerCroy
 
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationFrom Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationSafe Software
 
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...apidays
 
Top 10 Most Downloaded Games on Play Store in 2024
Top 10 Most Downloaded Games on Play Store in 2024Top 10 Most Downloaded Games on Play Store in 2024
Top 10 Most Downloaded Games on Play Store in 2024SynarionITSolutions
 
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, AdobeApidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobeapidays
 
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...apidays
 
AWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of TerraformAWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of TerraformAndrey Devyatkin
 
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemkeProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemkeProduct Anonymous
 

Último (20)

Manulife - Insurer Innovation Award 2024
Manulife - Insurer Innovation Award 2024Manulife - Insurer Innovation Award 2024
Manulife - Insurer Innovation Award 2024
 
Why Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire businessWhy Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire business
 
TrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
TrustArc Webinar - Stay Ahead of US State Data Privacy Law DevelopmentsTrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
TrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
 
Exploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone ProcessorsExploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone Processors
 
Artificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : UncertaintyArtificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : Uncertainty
 
Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024
 
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
 
HTML Injection Attacks: Impact and Mitigation Strategies
HTML Injection Attacks: Impact and Mitigation StrategiesHTML Injection Attacks: Impact and Mitigation Strategies
HTML Injection Attacks: Impact and Mitigation Strategies
 
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
 
Workshop - Best of Both Worlds_ Combine KG and Vector search for enhanced R...
Workshop - Best of Both Worlds_ Combine  KG and Vector search for  enhanced R...Workshop - Best of Both Worlds_ Combine  KG and Vector search for  enhanced R...
Workshop - Best of Both Worlds_ Combine KG and Vector search for enhanced R...
 
Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024
 
Scaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationScaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organization
 
🐬 The future of MySQL is Postgres 🐘
🐬  The future of MySQL is Postgres   🐘🐬  The future of MySQL is Postgres   🐘
🐬 The future of MySQL is Postgres 🐘
 
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationFrom Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
 
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
 
Top 10 Most Downloaded Games on Play Store in 2024
Top 10 Most Downloaded Games on Play Store in 2024Top 10 Most Downloaded Games on Play Store in 2024
Top 10 Most Downloaded Games on Play Store in 2024
 
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, AdobeApidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
 
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
 
AWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of TerraformAWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of Terraform
 
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemkeProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
 

AIR POLLUTION CONTROL Unit iv problem set

  • 1. Prof S S Jahagirdar, NKOCET AIR POLLUTION AND CONTROL (Elective-I) Problems set for UNIT-IV AIR POLLUTION METEOROLOGY Page | 1
  • 2. BE (Civil) L- ROLL NO- Air pollution (Elective -I) Unit-IV Stability conditions (Temperature gradient) Problems 1. On the basis of temperature gradient in the situation described below classify the degree of stability of atmosphere. i. ii. Temp at ground 350C and temp at 650 m height is 220 C iii. Temp at ground 250C and temp at 700 m height is 280 C iv. 2. Temp at ground 340C and temp at 500 m height is 400 C Temp at ground 250C and temp at 200 m height is 50 C Temperature at ground level is 30OC. Find the atmospheric stability condition in each of the following cases. Case Temp. (OC) I 700 10 II 500 34 III 1000 25 IV 3. Altitude (m) 500 20 Determine whether the atmosphere is unstable, neutral or stable for the following case. Initial Temperature 30.2 oC Final Temperature - 58.5 oC Initial Height 221 m Final Height 23214 m
  • 3. BE (Civil) L- ROLL NO- Air pollution (Elective -I) Unit-IV Finding Wind speed at higher altitudes Problems 1. The wind speed at 10 m altitude is 5m/s. Find the wind speed at 250 m altitude for the following stability conditions. i. ii. Zero or small lapse rate iii. Moderate inversion iv. 2. Large lapse rate Large inversion Wind speed at 10 m altitude is 2m/s. Find the wind speed at 200 m altitude for following cases i. ii. Zero lapse rate iii. Moderate inversion iv. 3. Large lapse rate Large inversion The ground level wind velocity at 10 m elevation is 5.2 m/sec in a city. What would you estimate the velocity to be at 125m elevation in moderately stable atmosphere?
  • 4. BE (Civil) L- ROLL NO- Air pollution (Elective -I) Unit-IV Maximum Mixing Depth (MMD) Problems 1. At a given location the ground Environmental air temperature is 180 C, while normal maximum surface temperature for the month is known to be 300 C. At an elevation of 700 m the temperature of the atmosphere measured is a) 150 C and b) 200 C. What is maximum mixing depth in meters for two cases? 2. Air parcel temp at ground level is 280C. The environmental temperature at ground level is 300 and at 500 m is 27.5 0C. Determine the MMD 3. A rising parcel of dry air has a temp of 300 C at sea level. Assuming DALR of 10C/100m, determine MMD if environmental temperature temp at sea level is 150C and ELR is +10C/100 m 4. In a given situation ground level temperature is 180C, while normal maximum surface temp for that month is a) 26 0C and b) 240C. At an elevation of 300 m the temperature is found to be 210C. What is MMD in metres for both the cases? 5. A rising parcel of dry air has a temp of 350 C at sea level. Assuming DALR of 10C/100m, determine MMD if environmental temperature temp at sea level is 150C and ELR is +10C/100 m 6. Determine the maximum mixing depth if flue gas temperature is 30oC, when: i) Average ground temperature is 20 oC and temperature at elevation of 600 m is 30oC ii) Average ground temperature is 25 oC and temperature at elevation of 500 m is 20oC Assume DALR= -9.8 oC/1000 m. 7. Calculate the maximum mixing height from the following early morning temperature data given below: Height (m) 0 250 350 450 550 650 Temperature (oC) 9.5 12.2 15.1 15.6 16.2 16.5 The maximum surface temperature for the day was 15oC.
  • 5. BE (Civil) L- ROLL NO- Air pollution (Elective -I) Unit-IV Minimum (safe) Stack height determination Problems 1. A factory uses 1.5 ML of fuel oil per month. The exhaust gases from factory contain the following quantities of pollutant per ML per year: i. Particulate matter = 5 t/yr ii. Sulphur dioxide= 21 t/yr Determine the safe height of chimney required for safe dispersion of pollutants. 2. A factory uses 2 ML of fuel oil per month. The exhaust gases from factory contain the following quantities of pollutant per ML per year: i. Particulate matter = 5 t/yr ii. Sulphur dioxide= 21 t/yr iii. Nitrogen dioxide= 4 t/yr Determine the safe height of chimney required for safe dispersion of pollutants.
  • 6. BE (Civil) L- ROLL NO- Air pollution (Elective -I) Unit-IV Plume rise Problems 1. The heat emission rate associated with a stack gas is 4800 KJ/sec, the wind and stack gas speeds are 5 m/s and 15 m/s respectively and the inside dia of stack top is 2m. Estimate the plume rise by i. ii. Concave iii. 2. Carson Mosses Holland’s formula The wind and stack gas speeds are 3 m/s and 6 m/s respectively and stack dia is 2m. The atmospheric stability condition is neutral with a temp of 3000K and the stack gas temp is 4400K. Estimate plume rise in m by Brigg’s equation and TVA model equation. 3. Determine the effective stack height given by following data i. ii. Inner dia of stack = 1.07 m iii. Air temp =130C iv. Barometric pressure = 1000 mbar v. Stack gas velocity = 9.14 m/s vi. Stack gas temperature = 1490 C vii. 4. Physical stack height= 203 m Wind velocity at stack top = 5 m/s Determine the effective stack height given by following data i. Physical stack height= 180 m ii. Inner dia of stack = 0.95 m iii. Air temp =20 0C iv. Barometric pressure = 1000 mbar v. Stack gas velocity =11.12 m/s vi. Stack gas temperature = 1600 C vii. Wind velocity at stack top = 2.75 m/s
  • 7. BE (Civil) L- ROLL NO- Air pollution (Elective -I) Unit-IV Emission rate Problems 1. A power plant burns coal at the rate of 500 kg/hr. It consists of ash 30 %, Sulphur -3 % and carbon 40 %. Determine the emission rates of SPM and SO2 in mg/m3 and gm/sec. 2. A power plant burns coal at 500 kg/hr per MWe. Capacity of power plant is 500 MWe. Coal contains 30 % ash and 1 % sulphur and 40 % carbon. Determine i) ii) SO2 and CO2 emission iii) 3. SPM emission Quantity of air required for combustion. A power plant burns coal at the rate of 500 kg/min. It consists of ash 30 %, Sulphur 1 % and carbon 40 %. Determine the emission rates of SPM, CO2 and SO2 in mg/m3 and gm/sec. 4. A power plant burns 25 tonnes of coal/day having 30% ash. Determine the efficiency of particulate matter control equipment to maintain SPM level below 150 microgram/m3. If stack dia is 2.5 m and flue gas velocity is 9 m/s. 5. A power plant uses 500 kg of coal/hr. Coal contains 40% ash and 2% sulphur. Stack diameter at exit is 2 m and the stack gas velocity is 20 m/s and temp is 1000C. Calculate i. SPM concentration in microgram/m3 ii. SO2 emission in ppm iii. How much efficiency should be kept for the dust control equipment to meet emission standard of 150 micrograms/m3
  • 8. BE (Civil) L- ROLL NO- Air pollution (Elective -I) Unit-IV Gaussian dispersion model Problems 1. A thermal power plant burns coal at the rate of 10 t/hr and discharges the fuel gas though a stack having effective height of 90 m. The coal has sulphur content of 4%. The wind speed at stack top is 6m/s. The atmospheric stability class is ‘C’. For this class at downwind distance of 2000m the constants σy and σz are 200 and 120 respectively. Find the concentration of sulphur dioxide at ground level at 2000m downwind and 500m crosswind distance. 2. A power plant burns 5 tons of coal per hour with 4% sulphur content, discharges the product through a stack with 75 m effective height. The velocity of wind at top of stack is 6 m/s and atmospheric stability class is ‘C’. Determine the maximum ground level concentration of SO2. Also determine the ground level concentrations at 3.0 km downwind and cross wind distance of 0.4 m on the either sides of centreline for ‘C’ class stability on the either side of centreline Distance in m σz in m 850 88 53 3000 3. σy in m 280 170 A coal fired power plant emits SO2 at a rate of 200 g/s. If effective stack height is 60 m determine the ground level concentration downwind if wind speed at 60 m height is 4 m/s and stability class prevailing is ‘B’ Distance 0.5 km 1 km 2 km 3 km σy in m 70 160 310 420 σz in m 50 140 360 700 Plot concentration versus distance on log x log scale. 4. A coal fired power plant burns 20,000 tonnes of coal per day. Coal contains 3% sulphur, physical stack height=150 m, stack dia at top 4m, Stack gas velocity= 20 m/s and temperature is 1400 C. Surrounding air temperature is 1200 C and pressure 1000 mbar. Wind speed at 150 m = 6 m/s, Env lapse rate = +10 C/100 m. Determine 1. Plume rise by Brigg’s formula 2. SO2 concentration at 1000 m downwind from stack (centreline) for ‘B’
  • 9. BE (Civil) L- ROLL NO- class stability, if σy in m= 170 and σz in m= 140 at 1000 m. 5. A coal fired power plant emits SO2 at a rate of 100 g/s. If effective stack height is 100 m determine the ground level concentration downwind if wind speed at 100 m height is 4 m/s and stability class prevailing is ‘B’ Distance 0.5 km 1 km 2 km 3 km σy in m 70 160 310 420 σz in m 50 140 360 700 Plot concentration versus distance on log x log scale. 6. A coal fired power plant emits SO2 at a rate of 300 g/s. If effective stack height is 150 m determine the ground level concentration downwind if wind speed at 10 m height is 4 m/s and stability class prevailing is ‘B’ Distance 1 km 2 km 3 km σy in m 70 160 310 420 σz in m 7. 0.5 km 50 140 360 700 SO2 is emitted at a rate of 0.9 kg/sec from a stack with effective height of 220 m. The wind speed at that height is 5 m/sec and stability category is ‘B’. Determine the downwind centre line concentration in micrograms/m3 at ground level distance from stack of 1) 0.5 km 2) 1km,3) 2km and 4) 3km. Plot C versus log of distance curve Distance 1 km 2 km 3 km σy in m 110 160 300 450 σz in m 8. 0.5 km 65 120 220 310 A coal fired power plant burns coal at the rate of 500 kg/hr. Coal contains 1% sulphur and 30% ash, physical stack height=100 with plume rise of 50 m. Wind speed at stack top is 5 m/sec. Determine 1. Determine SO2 and SPM emission rate. 2. Also determine GLC of SO2 and SPM at 1000m from stack for ‘B’ class stability, if σy in m= 60 and σz in m= 25 at 1000 m. Assume all the other data. 9. An industrial boiler is burning at 12 tons (10.9 mton) of 2.5% sulfur coal/hr with an emission rate of 151 g/s. The following conditions exist: H = 120 m, u = 2 m/s, y = 0. It is one hour before sunrise, and the sky is clear. Determine downwind ground level concentration at 10 km.
  • 10. BE (Civil) 10. L- ROLL NO- If emissions are from a ground level source with H = 0, u = 4 m/s, Q = 100 g/s, and the stability class = B, what is downwind concentration at 200 m? 11. A stack in an urban area is emitting 80 g/s of NO. It has an effective stack height of 100 m. The wind speed is 4 m/s at 10 m. It is a clear summer day with the sun nearly overhead. Estimate the ground level concentration at:a) 2 km downwind on the centerline and b) 2 km downwind, 0.1 km off the centerline.