The document presents a study on treating textile wastewater using chlorination. It describes installing a packed column to decolorize wastewater with chlorine gas. Water samples were tested for pH, TDS, TSS and COD before and after treatment. The results showed pH values between 8-9, and decreases in TDS, TSS and COD after treatment, indicating the process was effective at reducing contaminants. Recommendations include modifying the system for continuous operation and adding a backwash process for the column.
Exploring the Future Potential of AI-Enabled Smartphone Processors
Thesis presentation
1. Presentation on
Treatment of wastewater from textile
industry by chlorination method
Abdullah Al Loman
Student No: 0402011
2. Statement of the objective
Installation of a packed column for the purpose of de-colorization
of wastewater from the textile industry with chlorine gas.
To determine the physical parameters TDS and TSS and the
chemical parameters pH and COD of wastewater.
To determine the physical parameters TDS and TSS and the
chemical parameters pH and COD of treated waste water.
To compare those parameters of treated sample with the raw
sample.
4. Process Flow Diagram(PFD)
Flow meter To Atmosphere
Raw Wastewater Tank Packed
Column
C-101
P-101
T-101
Recycle to the tank
Air Mixing
Cl2 + Air
Flow meter
H2SO4 Produced Cl2
Reactor NaCl
MnO2
R-101
5. Experimental Set-up
Packed
Column
Flow
Meter Blower
Rotameter
Tank
Mixing
Chamber Round bottom
flask
Collector and
recycle to the tank
8. Results (cont’d…….)
The Graph of pH vs. time for the Experiment 1
(50 mg/L)
10
9
8
7
6
pH
5
4
3
2
1
0
0 10 20 30 40 50 60 70 80 90 100
Time (min)
9. Results (cont’d…….)
Before treatment After treatment
Figure: Color comparison of raw water with treated water for experiment no1
10. Conclusions
Installation of Packed Column
De-colorization of wastewater
TDS, TSS and COD values decreased
pH values were in the range of 8-9
11. Recommendation for further study
It could be done by continuous process
A concentration indicator could be installed after
Chlorine- Air mixing chamber
There should be exist back wash process of the column
The recycle process of the treated sample to the raw
sample tank should be modified