This manual is very much useful for PG students belongs to ME Power Electronics and Drives
By
M.MURUGANANDAM. M.E.,(Ph.D).,MIEEE.,MISTE,
Assistant Professor & Head / EIE,
Muthayammal Engineering College,
Rasipuram,
Namakkal-637 408.
Cell No: 9965768327
ICT role in 21st century education and it's challenges.
Modeling and Simulation Lab Manual ME PED
1. EE1303-Power Electronics Lab Manual
MUTHAYAMMAL ENGINEERING COLLEGE, RASIPURAM
Department of Electrical and Electronics Engineering
I Semester – ME (PED)
Modeling and Simulation Laboratory
Manual
Prepared by Approved by
Prof.M.Muruganandam, M.E.(Ph.D), Dr P.Murugesan,B.E.,Ph.D.,
AP / EEE Proff. & HOD/EEE
Revision No.:0 Date:15.09.2008
Muthayammal Engineering college, Rasipuram. 1
3. EE1303-Power Electronics Lab Manual
INSTRUCTIONS TO THE CANDIDATE
SAFETY:
You are doing experiments in Power Electronics lab with high voltage and
high current electric power. It may cause even a fatal or loss of energy of your
body system. To avoid this please keep in mind the followings
In case of any wrong observations, you have to SWITCH OFF the power
supply related with it.
You have to tuck in your shirts or wear an overcoat.
You have to wear shoes compulsorily and stand on mats made by
insulating materials to electrically isolate your body from the earth.
ATTENDANCE:
If you absent for a lab class then you have lost several things to learn.
Laboratory should be treated as temple, which will decide your life. So don’t fail
to make your presence with your record notebook having completed
experiments, observation with completed experiments, day’s experiment
particulars with required knowledge about it and stationeries.
RECORD:
Shows the performance of equipment and yourself. It will be very useful
for future reference. So keep it as follows.
Write neatly; as they have to be preserved enter the readings in the record
notebook those have been written in your observation.
Units should be written for all quantities.
Draw necessary graphs and complete the record before coming to the
next lab class.
Don’t forget to write the theory with precaution and inference of each
experiment.
MAY I HELP YOU
1. Device ratings should be noted.
2. Moving coil meters should be used for DC measurements.
3. Moving iron meters should be used for AC measurements.
4. Use isolated supply for the CRO.
5. Use attenuation probe for high voltage measurements in CRO.
Muthayammal Engineering college, Rasipuram. 3
5. EE1303-Power Electronics Lab Manual
CONTENTS
Sl.No. Name of the experiment Page No.
1. VI CHARACTERISTICS OF SCR 2
2. VI CHARACTERISTICS OF TRIAC 8
3. VI CHARACTERISTICS OF MOSFET 14
4. VI CHARACTERISTICS OF IGBT 20
5. TRANSIENT CHARACTERISTICS OF MOSFET AND SCR 24
6. SINGLE PHASE AC TO DC FULLY CONTROLLED CONVERTER 30
7. SINGLE PHASE AC TO DC HALF CONTROLLED CONVERTER 36
8. STEP DOWN MOSFET BASED CHOPPER 42
9. STEP UP MOSFET BASED CHOPPER 46
10. IGBT BASED SINGLE PHASE PWM INVERTER 50
SERIES RESONANT DC-DC CONVERTER
11. 56
(ZERO CURRENT SWITCHING)
PARALLEL RESONANT DC-DC CONVERTER
12. 60
(ZERO VOLTAGE SWITCHING)
Muthayammal Engineering college, Rasipuram. 5
6. EE1303-Power Electronics Lab Manual
TRANSIENT CHARACTERISTICS OF MOSFET AND SCR
CIRCUIT DIAGRAM:
FOR MOSFET
MATLAB CIRCUIT FOR MOSFET
Muthayammal Engineering college, Rasipuram. 6
7. EE1303-Power Electronics Lab Manual
TRANSIENT CHARACTERISTICS OF MOSFET AND SCR
AIM:
(i) Obtain and explain both turning ‘ON’ and turn ‘OFF’ characteristics of
given SCR
(ii) Obtain and explain both turning ‘ON’ and turn ‘OFF’ characteristics of
given MOSFET.
APPARATUS REQUIRED:
S.No. Blocks Type Items Quantity
1 Simulink
i. Sink Scope 1
ii. Source Pulse Generator 1
2 Sim power system
MC Ammeter 1
i. Measurements
MC Voltmeter 1
ii. Elements - RLC series branch 1
- MOSFET 1
iii. Power electronics
- SCR 1
iV. Electrical source - DC source 1
PROCEDURE:
FOR MOSFET
1. Open MATLAB and open Simulink then create a new file (new module)
2. Connections are made as per the circuit diagram by taking the required items
from the corresponding blocks.
3. According to the MOSFET, we should give the block parameter for MOSFET,
RLC series branch, pulse generator and the scope.
4. Now simulate the circuit. The graph of Gate pulse, Drain current and drain to
source voltage can be shown.
5. Finally the print out of the MATLAB circuit and the output is taken.
Muthayammal Engineering college, Rasipuram. 7
9. EE1303-Power Electronics Lab Manual
FOR SCR
1. Open MATLAB and open Simulink then create a new file (new module)
2. Connections are made as per the circuit diagram by taking the required items
from the corresponding blocks.
3. According to the SCR, we should give the block parameter for SCR, RLC series
branch, pulse generator and the scope.
4. Now simulate the circuit. The graph of Gate pulse, Anode current and anode to
cathode voltage can be shown.
5. Finally the print out of the MATLAB circuit and the output is taken.
Muthayammal Engineering college, Rasipuram. 9
10. EE1303-Power Electronics Lab Manual
MODEL GRAPH:
FOR MOSFET
FOR SCR
Muthayammal Engineering college, Rasipuram. 10
11. EE1303-Power Electronics Lab Manual
INFERENCE:
DISCUSSION QUESTIONS:
1. What is MATLAB?
2. What is a transient characteristic?
3. What is commutation?
4. Where the natural commutation is not possible in SCR?
5. What is the function of scope in MATLAB?
RESULT:
Muthayammal Engineering college, Rasipuram. 11
12. EE1303-Power Electronics Lab Manual
SINGLE PHASE AC TO DC FULLY CONTROLLED CONVERTER
CIRCUIT DIAGRAM FOR R LOAD
Model graph for R Load
°
( = 30°, R=100 )
Muthayammal Engineering college, Rasipuram. 12
13. EE1303-Power Electronics Lab Manual
SINGLE PHASE AC TO DC FULLY CONTROLLED CONVERTER
AIM:
(i) To study the operation of single phase fully controlled bridge converter with R
and R-L loads for continuous and discontinuous conduction modes.
(ii) Also find the performance parameters (Rectification efficiency, form factor,
peak inverse voltage and ripple factor)
APPARATUS REQUIRED:
S.No. Name of the item Type Range Quantity
1 1 SCR bridge module TYN612 600V,12A 1
2 SCR Triggering Kit - - 1
3 Ammeter MC (0-500) mA 1
4 Voltmeter MC (0-30) V 1
5 CRO - - 1
6 CRO Brobe - - 1
7 Patch Cards - - 10
FORMULA USED:
For R load
Vm
1. Average dc output voltage Vdc is Vdc = (1 + cos )
1
1 sin 2 2
2. RMS output voltage is Vrms Vrms = Vm +
2 2
For R-L load continuous conduction:
2Vm
1. Average dc output voltage Vdc is Vdc = cos
Vm
2. RMS output voltage Vrms is Vrms = = Vs
2
For RL load discontinuous conduction:
Vm
3. Average dc output voltage Vdc is Vdc = (cos cos )
1
V2 sin 2 sin 2 2
4. RMS output voltage Vrms is Vrms = m +
2 2 2
Muthayammal Engineering college, Rasipuram. 13
14. EE1303-Power Electronics Lab Manual
CIRCUIT DIAGRAM FOR R-L LOAD
Model graph for R-L Load with continuous conduction
°
( = 30°, R=100 , L=200mH)
Model graph for R-L Load with discontinuous conduction
°
( = 90°, R=100 , L=200mH)
Muthayammal Engineering college, Rasipuram. 14
15. EE1303-Power Electronics Lab Manual
General Formula:
2
Vdc
5. Rectification efficiency % = 2
Vrms
V
6. Form factor FF = rms
Vdc
7. Peak inverse voltage PIV = Vm
8. Ripple factor RF = FF 2 1
Where
Vm = maximum or peak voltage in volts = 2Vs
Vs = Supply voltage in volts
= Firing angle
= Extinction angle
= Conduction angle = -
Procedure:
1. Connections are made as per the circuit diagram for R load
2. Switch on the triggering kit
3. Switch on the 230 V AC supply
4. Switch on the debounce logic
5. By varying potentiometer vary the firing angle of the converter in order to vary the
output voltage step by step.
6. For each step note down the firing angle, output voltage and load current.
7. The output voltage is theoretically calculated for each step and the readings are
tabulated.
8. Repeat the same procedure for RL load.
Muthayammal Engineering college, Rasipuram. 15
16. EE1303-Power Electronics Lab Manual
Tabulation for R load:
Vs= R=
S.No. Firing Angle Idc Measured Vdc Measured Vdc Calculated Vrms Calculated
in degree in milliamps in volts in volts in volts
Tabulation for RL load:
Vs= R= L= =
S.No. Firing Angle Idc Measured Vdc Measured Vdc Calculated Vrms Calculated
in degree in milliamps in volts in volts in volts
Continuous conduction
Discontinuous conduction
Muthayammal Engineering college, Rasipuram. 16
17. EE1303-Power Electronics Lab Manual
INFERENCE:
DISCUSSION QUESTIONS:
1. What is inversion mode of operation?
2. When we connect a freewheeling diode in full converter, what will be the output?
3. Why the inversion mode is not possible in semi converter?
4. Why the power factor of full converter is lower than semi converter?
5. What is , , and µ?
RESULT:
Muthayammal Engineering college, Rasipuram. 17
18. EE1303-Power Electronics Lab Manual
SINGLE PHASE AC TO DC HALF CONTROLLED CONVERTER
CIRCUIT DIAGRAM FOR R LOAD
Model graph for R Load
°
( = 30°, R=100 )
Muthayammal Engineering college, Rasipuram. 18
19. EE1303-Power Electronics Lab Manual
SINGLE PHASE AC TO DC HALF CONTROLLED CONVERTER
AIM:
(i) To study the operation of single phase semi converter with R and R-L loads for
continuous and discontinuous conduction modes.
(ii) Also find the performance parameters (Rectification efficiency, form factor,
peak inverse voltage and ripple factor)
APPARATUS REQUIRED:
S.No. Name of the item Type Range Quantity
1 SCR module with protection TYN612 600V,12A 2
2 Diode module with protection BY126 - 3
3 SCR Triggering Kit - - 1
4 Battery - 12V 1
5 Ammeter MC (0-500) mA 1
6 Voltmeter MC (0-30) V 1
7 CRO - - 1
8 CRO Brobe - - 1
9 Patch Cards - - 10
FORMULA USED:
For R and RL load continuous & discontinuous conduction:
V
1. Average dc output voltage Vdc is Vdc = m (1 + cos )
1
1 sin 2 2
2. RMS output voltage is Vrms Vrms = Vm +
2 2
General Formula:
2
Vdc
3. Rectification efficiency % = 2
Vrms
V
4. Form factor FF = rms
Vdc
5. Peak inverse voltage PIV = Vm
6. Ripple factor RF = FF 2 1
Where
Vm = maximum or peak voltage in volts = 2Vs
Vs = Supply voltage in volts
= Firing angle
= Extinction angle
Muthayammal Engineering college, Rasipuram. 19
20. EE1303-Power Electronics Lab Manual
= Conduction angle = -
CIRCUIT DIAGRAM FOR R-L LOAD
Model graph for R-L Load with continuous conduction
°
( = 30°, R=100 , L=100mH)
Model graph for R-L Load with discontinuous conduction
°
( = 90°, R=100 , L=100mH)
Muthayammal Engineering college, Rasipuram. 20
21. EE1303-Power Electronics Lab Manual
Procedure:
1. Connections are made as per the circuit diagram for RL load
2. Switch on the triggering kit
3. Switch on the 230V AC supply
4. Switch on the debounce logic
5. By varying potentiometer vary the firing angle of the converter in order to vary the
output voltage step by step.
6. For each step note down the firing angle, output voltage and load current.
7. The output voltage is theoretically calculated for each step and the readings are
tabulated.
8. Repeat the same procedure for RL load.
Muthayammal Engineering college, Rasipuram. 21
22. EE1303-Power Electronics Lab Manual
Tabulation for R load:
Vs= R=
S.No. Firing Angle Idc Measured Vdc Measured Vdc Calculated Vrms Calculated
in degree in milliamps in volts in volts in volts
Tabulation for RL load:
S.No. Firing Angle Idc Measured Vdc Measured Vdc Calculated Vrms Calculated
in degree in milliamps in volts in volts in volts
Continuous conduction
Discontinuous conduction
Muthayammal Engineering college, Rasipuram. 22
23. EE1303-Power Electronics Lab Manual
INFERENCE:
DISCUSSION QUESTIONS:
1. What is power electronics?
2. What are the types of converter in power electronics?
3. What is firing angle?
4. What is active load?
5. Why the negative voltage is not possible in semi converter?
6. What is freewheeling diode?
7. Is a separate freewheeling diode necessary for semi converter? Justify your answer.
RESULT:
Muthayammal Engineering college, Rasipuram. 23
24. EE1303-Power Electronics Lab Manual
STEP DOWN MOSFET BASED CHOPPER
CIRCUIT DIAGRAM
MODEL GRAPH
Muthayammal Engineering college, Rasipuram. 24
25. EE1303-Power Electronics Lab Manual
STEP DOWN MOSFET BASED CHOPPER
AIM:
To study the waveform for MOSFET based step down chopper for different load
for continuous and discontinuous conduction modes.
APPARATUS REQUIRED:
S.No. Name of the item Type Range Quantity
1 MOSFET Module IRF 840 - 1
2 Ammeter MC (0-500mA) 1
3 Voltmeter MC (0-30V) 1
4 Rheostat - - 1
5 RPS - (0-30V) 1
6 CRO - - 1
7 CRO Probe - - 1
8 Patch cards - - -
FORMULA USED:
1. Average dc output voltage Vdc is Vdc = Vs
2. RMS output voltage Vrms is Vrms = Vs
Where:
TON
= Duty cycle of the chopper =
T
TON = on time
T = Total time
Procedure:
1. Connections are made as per the circuit diagram.
2. Switch on the RPS and turn on triggering kit
3. Switch on the debounce logic
4. By changing the width of the pulse, obtain the different set of reading.
5. For each step note down the duty cycle, output voltage and load current and
tabulate it.
6. The output voltage is theoretically calculated.
7. Draw the graph as per the reading in the table.
Muthayammal Engineering college, Rasipuram. 25
26. EE1303-Power Electronics Lab Manual
TABULATION:
Vs= T=
S.No. TON TON Idc (Avg) Vdc (Avg) Vdc (Avg)
in ms = Measured Measured Calculated
T
in mA in volts in volts
Vdc = Vs
1
2
3
4
5
Muthayammal Engineering college, Rasipuram. 26
27. EE1303-Power Electronics Lab Manual
INFERENCE:
DISCUSSION QUESTIONS:
1. What is chopper and what are the devices generally used for chopper?
2. What are the types of chopper?
3. What is step down chopper?
4. What are the control strategies used for choppers?
5. Why frequency modulation is not preferred mostly?
6. Why thyristor is not preferred in chopper circuit mostly?
RESULT:
Muthayammal Engineering college, Rasipuram. 27
28. EE1303-Power Electronics Lab Manual
STEP UP MOSFET BASED CHOPPER
CIRCUIT DIAGRAM:
Model graph for step up operation
Muthayammal Engineering college, Rasipuram. 28
29. EE1303-Power Electronics Lab Manual
STEP UP MOSFET BASED CHOPPER
AIM:
To study the waveform for MOSFET based step up chopper for different load for
continuous and discontinuous conduction modes.
APPARATUS REQUIRED:
S.No. Name of the item Type Range Quantity
1 MOSFET Module IRF 840 - 1
2 Ammeter MC (0-500mA) 1
3 Voltmeter MC (0-30V) 1
4 Rheostat - - 1
5 RPS - (0-30V) 1
6 Diode Py 127 - 1
7 Inductor Ferrite core 100mH 1
8 CRO - - 1
9 CRO Probe - - 1
10 Patch cards - - -
FORMULA USED:
Vs
Average dc output voltage Vdc is Vdc =
(1 )
Where:
TON
= Duty cycle of the chopper =
T
TON = on time
T = Total time
PROCEDURE:
1. Connections are made as per the circuit diagram
2. Switch on the RPS and turn on triggering kit
3. Switch on the debounce logic
4. By changing the width of the pulse, obtain the different set of reading.
5. For each step note down the duty cycle, output voltage and load current and
tabulate it.
6. The output voltage is theoretically calculated for each step.
7. Draw the graph as per the reading in the table.
Muthayammal Engineering college, Rasipuram. 29
30. EE1303-Power Electronics Lab Manual
TABULATION:
Vs= T=
S.No. TON TON Idc (Avg) Vdc (Avg) Vdc (Avg)
in ms = Measured Measured Calculated
T
in mA in volts in volts
Vs
Vdc =
(1 )
1
2
3
4
5
Muthayammal Engineering college, Rasipuram. 30
31. EE1303-Power Electronics Lab Manual
INFERENCE:
DISCUSSION QUESTIONS:
1. What is chopper and what are the devices generally used for chopper?
2. What are the types of chopper?
3. What is step up chopper?
4. What are the control strategies used for choppers?
5. Why frequency modulation is not preferred mostly?
6. Why thyristor is not preferred in chopper circuit mostly?
RESULT:
Muthayammal Engineering college, Rasipuram. 31
32. EE1303-Power Electronics Lab Manual
IGBT BASED SINGLE PHASE PWM INVERTER
CIRCUIT DIAGRAM
Muthayammal Engineering college, Rasipuram. 32
33. EE1303-Power Electronics Lab Manual
IGBT BASED SINGLE PHASE PWM INVERTER
AIM:
To study the operation of single-phase bridge inverter with sinusoidal pulse width
modulation with R load.
APPARATUS REQUIRED:
S.No. Name of the item Type Range Quantity
1 IGBT Module - - 1
2 Inverter control module - - 1
3 CRO - - 1
4 Ammeter MI (0-5A) 1
5 Voltmeter MI (0-300V) 1
6 Patch cards - - -
FORMULA USED:
1. Modulation index (m) is m = Ar / Ac
2. Output voltage V0 = m Vs
Where
Ar = Amplitude of reference signal
Ac = Amplitude of carrier signal
Vs = Source voltage
Muthayammal Engineering college, Rasipuram. 33
34. EE1303-Power Electronics Lab Manual
Model graph
Sinusoidal Pulse width modulation
Voltage and current waveforms
Muthayammal Engineering college, Rasipuram. 34
35. EE1303-Power Electronics Lab Manual
Precaution:
1. Check whether AC main switch is off condition in both the trainer.
2. Check whether control module mode selector switch is in first position (Sine
wave).
3. Check whether control module pulse release switch SW4 in control module is off
position.
4. Check whether 24V AC switch is in off position.
Procedure:
1. Make the connection as per the circuit diagram.
2. Switch on the AC main in both the trainer.
3. Measure the amplitude and frequency of sine wave and carrier triangular wave
and tabulate it. Also adjust sine wave frequency to 50Hz.
4. Connect CRO probe to observe the load voltage and load current waveform.
5. Release the switch SW4 in the inverter control module and switch SW1 in the
IGBT power module.
6. Measure the output voltage.
7. Using the amplitude POT to vary step by step, for each step note down the
amplitude and frequency of sine wave and triangular waveform and also
measure the output voltage and tabulate it.
8. Then find the theoretical output voltage by using the formula.
Muthayammal Engineering college, Rasipuram. 35
36. EE1303-Power Electronics Lab Manual
Tabulation:
Vs=
S.No. Amplitude Amplitude Modulation I0 V0 V0
of carrier of index Measured Measured Calculated
triangular reference m= Ar/Ac in Amps in Volts in Volts
wave sine wave V0 = m X V s
(Ac) in (Ar) in
volts volts
1
2
3
4
5
6
Muthayammal Engineering college, Rasipuram. 36
37. EE1303-Power Electronics Lab Manual
INFERENCE:
DISCUSSION QUESTIONS:
1. What is inverter?
2. Why we go for PWM?
3. What are the different types of PWM?
4. What is modulation index and what are the types?
5. What are the advantages of IGBT?
RESULT:
Muthayammal Engineering college, Rasipuram. 37
38. EE1303-Power Electronics Lab Manual
SERIES RESONANT DC-DC CONVERTER
(ZERO CURRENT SWITCHING)
CIRCUIT DIAGRAM:
MODEL GRAPH:
Muthayammal Engineering college, Rasipuram. 38
39. EE1303-Power Electronics Lab Manual
SERIES RESONANT DC-DC CONVERTER
(ZERO CURRENT SWITCHING)
AIM:
To determine the voltage and current wave form of series resonant dc-dc
converter (Zero current switching).
APPARATUS REQUIRED:
S.No. Name of the item Type Range Quantity
1 Resonant converter module VPET-315 - 1
2 Ammeter MC (0-2) A 1
3 Voltmeter MC (0-30) V 1
4 CRO - - 1
5 CRO Brobe - - 1
6 Patch Cards - - 10
FORMULA USED:
1
Frequency f = Hz
T
Where:
T= Time
f = Frequency
PRECAUTIONS:
Initially keep the frequency adjustment POT in minimum position
PROCEDURE:
1. Connections are made as per the circuit diagram.
2. Initially keep frequency adjustment POT in minimum position.
3. Switch on the main supply
4. Connect the “P” Pin connector from PWM output and PWM input
5. Connect the banana connector P10 to P4 , P8 to P11
6. Connect the current sensing resistor (1 / 20 W) across the banana connector P2
to P3.
7. The voltmeter is connected across P5 and P12
Muthayammal Engineering college, Rasipuram. 39
40. EE1303-Power Electronics Lab Manual
TABULATION:
Switching
Output Output
S.No. Time (ms) Frequency
Voltage (V) Current (A)
(KHz)
1
2
3
4
5
Muthayammal Engineering college, Rasipuram. 40
41. EE1303-Power Electronics Lab Manual
8. Connected the R load across P5 and P12 through ammeter.
9. Adjust the frequency POT and set switching frequency 40KHz.
10. Connect the CRO across the connector T1 (+) and ground. Another channel is
connected to P2 (+), P3 (-)
11. Now observe the switch voltage and current wave.
12. Similarly observe the switch voltage and current waveform for various switching
frequency.
INFERENCE:
DISCUSSION QUESTIONS:
1. What is resonance?
2. What is the condition for resonance?
3. What are the advantages of resonant converter?
4. What is soft switching?
5. What types of resonant converter?
6. What is zero current switching?
7. What is zero voltage switching?
RESULT:
Muthayammal Engineering college, Rasipuram. 41
43. EE1303-Power Electronics Lab Manual
PARALLEL RESONANT DC-DC CONVERTER
(ZERO VOLTAGE SWITCHING)
AIM:
To determine the voltage and current wave form of parallel resonant dc-dc
converter (Zero voltage switching).
APPARATUS REQUIRED:
S.No. Name of the item Type Range Quantity
1 Resonant converter module VPET-315 - 1
2 Ammeter MC (0-2) A 1
3 Voltmeter MC (0-30) V 1
4 CRO - - 1
5 CRO Brobe - - 1
6 Patch Cards - - 10
FORMULA USED:
1
Frequency f = Hz
T
Where:
T= Time
f = Frequency
PRECAUTIONS:
Initially keep the frequency adjustment POT in minimum position
PROCEDURE:
1. Connections are made as per the circuit diagram.
2. Initially keep frequency adjustment POT in minimum position.
3. Switch on the main supply
4. Connect the “9” Pin connector from PWM output and PWM input
5. Connect the banana connector P10 to P4, P8 to P11
6. Connect the current sensing resistor (1 / 20 W) across the banana connector P2
to P3.
7. The voltmeter is connected across P5 and P12
Muthayammal Engineering college, Rasipuram. 43
44. EE1303-Power Electronics Lab Manual
TABULATION:
Switching
Output Output
S.No. Time (ms) Frequency
Voltage (V) Current (A)
(KHz)
1
2
3
4
5
Muthayammal Engineering college, Rasipuram. 44
45. EE1303-Power Electronics Lab Manual
8. Connected the R load across P5 and P12 through ammeter.
9. Adjust the frequency POT and set switching frequency 40KHz.
10. Connect the CRO across the connector T1 (+) and ground. Another channel is
connected to P2 (+), P3 (-)
11. Now observe the switch voltage and current wave.
12. Similarly observe the switch voltage and current waveform for various switching
frequency.
INFERENCE:
DISCUSSION QUESTIONS:
1. What is resonance?
2. What is the condition for resonance?
3. What are the advantages of resonant converter?
4. What is soft switching?
5. What types of resonant converter?
6. What is zero current switching?
7. What is zero voltage switching?
RESULT:
Muthayammal Engineering college, Rasipuram. 45