EnOcean Equipment Profiles No Wires. No Batteries. No Limits 06 Enero 2010
Standardization of Radio Protocol ,[object Object],[object Object],RF SIGNAL Physical ,[object Object],[object Object],[object Object],ENCODED TELEGRAM (Bits) Data Link ,[object Object],DECODED TELEGRAM (Bytes: ORG, ID, Data, Status) Transport Network Formal standardization  at IEC ,[object Object],[object Object],DATA ENCR./DECR.  Presentation Standardization started within  EnOcean Alliance Version 2.0 available ,[object Object],[object Object],DATA INTERPRETATION Application Standardization Task Action Data Unit Layer
EnOcean Protocol. Application Layer
EnOcean Telegrams types – ORG EEP and Data payload Definition The EEP is defined as following: ORG – FUNC (profile) – TYPE  Ranges:  ORG  0x00 … 0xFF   FUNC 0x00 … 0x3F   TYPE 0x00 … 0x7F
ORG 7 – 4BS Telegrams Functions - Profiles ,[object Object],[object Object],To keep the radio telegram as short as possible the transmitter will inform the receiver only during the teach-in procedure about its characteristics. Sensor 1.  Press LRN pushbutton 2.  LRN telegramm will be send
EnOcean Equipment Profiles – ORG 5 –  ORG 6 i.e STM250-Wireless window contact 06-00-01 01-Single Input Contact 00-Contacts &  Switches ORG 6 1BS Telegram   05-10-00 00-Window Handle 10-Mechanical Handle     tbd 05-Position Switch, Industrial Application Insertion of Key Card generates an N-Message, take-out a U-Message 05-04-01 01-Key Card Activated Switch 04-Position Switch, Home and Office application This EEP definition is based on the assumption that a RPS switch module (e.g. PTM200) is installed in an I-STATE up position! Application Style 2 is typically used in US and CAN but may be found in other markets as well. 05-03-02 02-Light and Blind Control-Application Style 2   This EEP definition is based on the assumption that a RPS switch module (e.g. PTM200) is installed in a 0-STATE up position! Application Style 1 is widely used in EU but may be found in other markets as well. 05-03-01 01-Light and Blind Control-Application Style 1 03-Rocker Switch 4 rocker This EEP definition is based on the assumption that a RPS switch module (e.g. PTM200) is installed in an I-STATE up position! Application Style 2 is typically used in US and CAN but may be found in other markets as well. 05-02-02 02-Light and Blind Control-Application Style 2   This EEP definition is based on the assumption that a RPS switch module (e.g. PTM200) is installed in a 0-STATE up position! Application Style 1 is widely used in EU but may be found in other markets as well. 05-02-01 01-Light and Blind Control-Application Style 1 02-Rocker Switch 2 rocker Comments EEP TYPE FUNCTION -PROFILE ORG 5 RPS Telegram
EEP – ORG 7 – 4BS – Function 2 DB_1: Temperature, linear n=255…0 07-02-1B 1B-Range +50ºC to +130ºC DB_1: Temperature, linear n=255…0 07-02-1A 1A-Range +40ºC to +120ºC DB_1: Temperature, linear n=255…0 07-02-19 19-Range +30ºC to +110ºC DB_1: Temperature, linear n=255…0 07-02-18 18-Range +20ºC to +100ºC DB_1: Temperature, linear n=255…0 07-02-17 17-Range +10ºC to +90ºC DB_1: Temperature, linear n=255…0 07-02-16 16-Range 0ºC to +80ºC DB_1: Temperature, linear n=255…0 07-02-15 15-Range -10ºC to +70ºC DB_1: Temperature, linear n=255…0 07-02-14 14-Range -20ºC to +60ºC DB_1: Temperature, linear n=255…0 07-02-13 13-Range -30ºC to +50ºC DB_1: Temperature, linear n=255…0 07-02-12 12-Range -40ºC to +40ºC DB_1: Temperature, linear n=255…0 07-02-11 11-Range -50ºC to +30ºC DB_1: Temperature, linear n=255…0 07-02-10 10-Range -60ºC to +20ºC DB_1: Temperature, linear n=255…0 07-02-0B 0B-Range +60ºC to +100ºC DB_1: Temperature, linear n=255…0 07-02-0A 0A-Range +50ºC to +90ºC DB_1: Temperature, linear n=255…0 07-02-09 09-Range +40ºC to +80ºC DB_1: Temperature, linear n=255…0 07-02-08 08-Range +30ºC to +70ºC DB_1: Temperature, linear n=255…0 07-02-07 07-Range +20ºC to +60ºC DB_1: Temperature, linear n=255…0 07-02-06 06-Range +10ºC to +50ºC DB_1: Temperature, linear n=255…0 07-02-05 05-Range 0ºC to +40ºC DB_1: Temperature, linear n=255…0 07-02-04 04-Range -10ºC to +30ºC DB_1: Temperature, linear n=255…0 07-02-03 03-Range -20ºC to +20ºC DB_1: Temperature, linear n=255…0 07-02-02 02-Range -30ºC to +10ºC DB_1: Temperature, linear n=255…0 07-02-01 01-Range -40ºC to 0ºC 02-Temperature Sensor Comments EEP TYPE FUNCTION -PROFILE ORG 7 4BS Telegram
EEP – ORG 7 – 4BS – Functions 4…9 tbd 07-09-0C 0C-Propane Sensor tbd 07-09-08 08-O2 Sensor tbd 07-09-04 04-CO2 Sensor   07-09-01 01-CO Sensor 09-Gas Sensor DB_3: Supply voltage 0…5,1V, linear n=0…255 DB_2: Illuminance 0…1530lx, linear n=255…0 DB_1: Temperature -30…50ºC, linear n=255…0 07-08-02 02-Range 0lx to 1530lx -30ºC to +50ºC and Occupancy DB_3: Supply voltage 0…5,1V, linear n=0…255 DB_2: Illuminance 0…1020lx, linear n=255…0 DB_1: Temperature 0…51ºC, linear n=255…0 07-08-02 02-Range 0lx to 1020lx 0ºC to +51ºC and Occupancy DB_3: Supply voltage 0…5,1V, linear n=0…255 DB_2: Illuminance 0…510lx, linear n=255…0 DB_1: Temperature 0…51ºC, linear n=255…0 07-08-01 01-Range 0lx to 510lx 0ºC to +51ºC and Occupancy 08-Light, Temperature&Occupancy Sensor DB_1: PIR Status 0…127 PIR off, 127…255 PIR on The transmission of "PIR off" telegrams is optional 07-07-01 01-Occupancy 07-Occupancy Sensor DB_3: Supply voltage 0…5,1V, linear n=0…255 DB_2: Illuminance 0…510lx, linear n=255…0 DB_1: Illuminance 0…1.024lx, linear n=255…0 07-06-02 02-Range 0lx to 1.024lx DB_3: Supply voltage 0…5,1V, linear n=0…255 DB_2: Illuminance 300…30.000lx, linear n=255…0 DB_1: Illuminance 600…60.000lx, linear n=255…0 07-06-01 01-Range 300lx to 60.000lx 06-Light Sensor     tbd 05-Pressure Sensor DB_2: Rel. Humidity 0…100%, linear n=255…0 DB_1: Temperature, 0…40ºC, linear n=255…0 07-04-01 01-Range 0ºC to +40ºC and 0% to 100% 04-Temperature & Humidity Sensor Comments EEP TYPE FUNCTION -PROFILE ORG 7 4BS Telegram
EEP – ORG 7 – 4BS – Function 10 DB_3: Turn-switch for fan speed DB_1: Temperature, 0…40ºC, linear n=255…0 DB_0.bit_0: Slide switch O/I, Day/Night 07-10-09 09-Temperature Sensor, Fan Speed and Day/Night Control DB_3: Turn-switch for fan speed DB_1: Temperature, 0…40ºC, linear n=255…0 DB_0.bit_0: Occupancy button 07-10-08 08-Temperature Sensor, Fan Speed and Ocuppancy Control DB_3: Turn-switch for fan speed DB_1: Temperature, 0…40ºC, linear n=255…0 07-10-07 07-Temperature Sensor, Fan Speed Control DB_2: Set point, min…max +, linear n=0…255 DB_1: Temperature, 0…40ºC, linear n=255…0 DB_0.bit_0: Slide switch O/I, Day/Night 07-10-06 06-Temperature Sensor, set point and Day/Night Control DB_2: Set point, min…max +, linear n=0…255 DB_1: Temperature, 0…40ºC, linear n=255…0 DB_0.bit_0: Slide switch O/I, Day/Night 07-10-05 05-Temperature Sensor, set point and Occupancy Control DB_3: Turn-switch for fan speed DB_2: Set point, min…max +, linear n=0…255 DB_1: Temperature, 0…40ºC, linear n=255…0 07-10-04 04-Temperature Sensor, set point and Fan Speed Control DB_2: Set point, min…max +, linear n=0…255 DB_1: Temperature, 0…40ºC, linear n=255…0 07-10-03 03-Temperature Sensor, set point control DB_3: Turn-switch for fan speed DB_2: Set point, min…max +, linear n=0…255 DB_1: Temperature, 0…40ºC, linear n=255…0 DB_0.bit_0: Slide switch O/I, Day/Night 07-10-02 02-Temperature Sensor, set point, Fan Speed and Day/Night Control DB_3: Turn-switch for fan speed DB_2: Set point, min…max +, linear n=0…255 DB_1: Temperature, 0…40ºC, linear n=255…0 DB_0.bit_0: Occupancy button 07-10-01 01-Temperature Sensor, set point, Fan Speed and Ocuppancy Control 10-Room Operating Panel Comments EEP TYPE FUNCTION -PROFILE ORG 7 4BS Telegram
EEP – ORG 7 – 4BS – Function 10 DB_2: Rel. Humidity 0…100%, linear n=0…250 DB_1: Temperature, 0…40ºC, linear n=0…250 DB_0.bit_0: Slide Switch 0/I or Slide switch Day/Night 07-10-14 14-Temperature and Humidity Sensor, Day/Night Control DB_2: Rel. Humidity 0…100%, linea nr=0…250 DB_1: Temperature, 0…40ºC, linear n=0…250 DB_0.bit_0: Occupancy button 07-10-13 13-Temperature and Humidity Sensor, Occupancy Control DB_3: Set point, min…max +, linear n=0…255 DB_2: Rel. Humidity 0…100%, linear n=0…250 DB_1: Temperature, 0…40ºC, linear n=0…250 07-10-12 12-Temperature and Humidity Sensor, set point Control DB_3: Set point, min…max +, linear n=0…255 DB_2: Rel. Humidity 0…100%, linear n=0…250 DB_1: Temperature, 0…40ºC, linear n=0…250 DB_0.bit_0: Slide Switch 0/I or Slide switch Day/Night 07-10-11 11-Temperature and Humidity Sensor, set point and Day/Night Control DB_3: Set point, min…max +, linear n=0…255 DB_2: Rel. Humidity 0…100%, linear n=0…250 DB_1: Temperature, 0…40ºC, linear n=0…250 DB_0.bit_0: Ocuupancy button 07-10-10 10-Temperature and Humidity Sensor, set point and Occupancy Control DB_1: Temperature, 0…40ºC, linear n=255…0 DB_0.bit_0: Slide switch 07-10-0D 0D-Temperature Sensor and Day/Night Control DB_1: Temperature, 0…40ºC, linear n=255…0 DB_0.bit_0: Occupancy 07-10-0C 0C-Temperature Sensor and Occupancy Control DB_1: Temperature, 0…40ºC, linear n=255…0 DB_0.bit_0: Input State 07-10-0B 0B-Temperature Sensor and Single Input Contact DB_2: Set point, min…max +, linear n=0…255 DB_1: Temperature, 0…40ºC, linear n=255…0 DB_0.bit_0: Contact State 07-10-0A 0A-Temperature Sensor, Set Point Adjust and Single Input Contact 10-Room Operating Panel Comments EEP TYPE FUNCTION -PROFILE ORG 7 4BS Telegram
EEP – ORG 7 – 4BS – Functions 11, 30, 38, 3F This profile is intended for manufacturer specific applications. Every manufacturer may independently define the types within this profile. 07-3F-7F 7F-Universal 3F-Universal Commands 0x8x to 0xFE are not used 07-38-08 08-PHC Gateway DB_3: Command 0h02 dimming value, ramping time, dimming range, store final value…   Dimming DB_3: Command 0h01 time, delay…   Switching 38-Central Command (0h01…0h7F) DB_0.bit0: Input State 07-30-02 02-Single Input Contact DB_2: Supply voltage 0…120 battery LOW, 121…255 battery OK DB_1: Input State, 0…195 contact closed, 196…255 Contact open 07-30-01 01-Single Input, Battery Monitor 30-Digital Input DB_3: Illuminance 0...510lx, linear n=0…255 DB_2: Illuminance set point, min...max, linear n=0…255 DB_1: Dimming output level, min...max, linear n=0…255 DB_0.bit_7: Repeater DB_0.bit_6: Power Relay Timer DB_0.bit_5: Daylight Harvesting DB_0.bit_4: Dimming DB_0.bit_2: Magnet Contact DB_0.bit_1: Occupancy DB_0.bit_0: Power Relay 07-11-01 01-Lighting Controller 11-Controller Status Comments EEP TYPE FUNCTION -PROFILE ORG 7 4BS Telegram

Más contenido relacionado

Similar a EEP-EnOcean Profiles v02.00

"Man-in-the-SCADA": Anatomy of Data Integrity Attacks in Industrial Control S...
"Man-in-the-SCADA": Anatomy of Data Integrity Attacks in Industrial Control S..."Man-in-the-SCADA": Anatomy of Data Integrity Attacks in Industrial Control S...
"Man-in-the-SCADA": Anatomy of Data Integrity Attacks in Industrial Control S...Marina Krotofil
 
Bt0064 logic design2
Bt0064 logic design2Bt0064 logic design2
Bt0064 logic design2Techglyphs
 
discharging-conditions-parameters-explanation-of-c.pdf
discharging-conditions-parameters-explanation-of-c.pdfdischarging-conditions-parameters-explanation-of-c.pdf
discharging-conditions-parameters-explanation-of-c.pdfRobin Yu
 
osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdfosw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdfGLsun Mall
 
Temperature Monitoring System with remote calibration capability
Temperature Monitoring System with remote calibration capabilityTemperature Monitoring System with remote calibration capability
Temperature Monitoring System with remote calibration capabilitykashyap velpuru
 
2N2222のデータシート(英語版)
2N2222のデータシート(英語版)2N2222のデータシート(英語版)
2N2222のデータシート(英語版)Tsuyoshi Horigome
 
LISUN Scientific grade-ccd-spectroradiometer-integrating-sphere-system-9500
 LISUN Scientific grade-ccd-spectroradiometer-integrating-sphere-system-9500 LISUN Scientific grade-ccd-spectroradiometer-integrating-sphere-system-9500
LISUN Scientific grade-ccd-spectroradiometer-integrating-sphere-system-9500世满 江
 
AUTOMATIC TEMPERATURE FAN CONTROLLER
AUTOMATIC TEMPERATURE FAN CONTROLLERAUTOMATIC TEMPERATURE FAN CONTROLLER
AUTOMATIC TEMPERATURE FAN CONTROLLERMuhammadFazilMemon
 
Ccd spectroradiometer-integrating-sphere-compact-system-for-led-7000vis
Ccd spectroradiometer-integrating-sphere-compact-system-for-led-7000visCcd spectroradiometer-integrating-sphere-compact-system-for-led-7000vis
Ccd spectroradiometer-integrating-sphere-compact-system-for-led-7000vis世满 江
 
Precision Remote Diode Digital Temperature Sensor: LM95245
Precision Remote Diode Digital Temperature Sensor: LM95245Precision Remote Diode Digital Temperature Sensor: LM95245
Precision Remote Diode Digital Temperature Sensor: LM95245Premier Farnell
 
Conversor a d mcp3201
Conversor a d mcp3201Conversor a d mcp3201
Conversor a d mcp3201Samuel Borges
 
PIC Microcontroller
PIC MicrocontrollerPIC Microcontroller
PIC MicrocontrollerDivya Bansal
 
rae_mic2_sensors_and_signals for study purposes
rae_mic2_sensors_and_signals for study purposesrae_mic2_sensors_and_signals for study purposes
rae_mic2_sensors_and_signals for study purposes134483
 
UP product catalog
UP product catalogUP product catalog
UP product catalogUP Group
 
UNIT 4 & 5 - I nterfacing_Lecture7.pptx
UNIT 4 & 5 - I         nterfacing_Lecture7.pptxUNIT 4 & 5 - I         nterfacing_Lecture7.pptx
UNIT 4 & 5 - I nterfacing_Lecture7.pptxnaveen088888
 

Similar a EEP-EnOcean Profiles v02.00 (20)

"Man-in-the-SCADA": Anatomy of Data Integrity Attacks in Industrial Control S...
"Man-in-the-SCADA": Anatomy of Data Integrity Attacks in Industrial Control S..."Man-in-the-SCADA": Anatomy of Data Integrity Attacks in Industrial Control S...
"Man-in-the-SCADA": Anatomy of Data Integrity Attacks in Industrial Control S...
 
EI 2406 instrumentation system design laboratory
EI 2406 instrumentation system design laboratoryEI 2406 instrumentation system design laboratory
EI 2406 instrumentation system design laboratory
 
Bt0064 logic design2
Bt0064 logic design2Bt0064 logic design2
Bt0064 logic design2
 
discharging-conditions-parameters-explanation-of-c.pdf
discharging-conditions-parameters-explanation-of-c.pdfdischarging-conditions-parameters-explanation-of-c.pdf
discharging-conditions-parameters-explanation-of-c.pdf
 
osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdfosw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
 
Temperature Monitoring System with remote calibration capability
Temperature Monitoring System with remote calibration capabilityTemperature Monitoring System with remote calibration capability
Temperature Monitoring System with remote calibration capability
 
MAX6675.pdf
MAX6675.pdfMAX6675.pdf
MAX6675.pdf
 
2N2222のデータシート(英語版)
2N2222のデータシート(英語版)2N2222のデータシート(英語版)
2N2222のデータシート(英語版)
 
LISUN Scientific grade-ccd-spectroradiometer-integrating-sphere-system-9500
 LISUN Scientific grade-ccd-spectroradiometer-integrating-sphere-system-9500 LISUN Scientific grade-ccd-spectroradiometer-integrating-sphere-system-9500
LISUN Scientific grade-ccd-spectroradiometer-integrating-sphere-system-9500
 
Microcontroller ppt
Microcontroller pptMicrocontroller ppt
Microcontroller ppt
 
AUTOMATIC TEMPERATURE FAN CONTROLLER
AUTOMATIC TEMPERATURE FAN CONTROLLERAUTOMATIC TEMPERATURE FAN CONTROLLER
AUTOMATIC TEMPERATURE FAN CONTROLLER
 
Ccd spectroradiometer-integrating-sphere-compact-system-for-led-7000vis
Ccd spectroradiometer-integrating-sphere-compact-system-for-led-7000visCcd spectroradiometer-integrating-sphere-compact-system-for-led-7000vis
Ccd spectroradiometer-integrating-sphere-compact-system-for-led-7000vis
 
Precision Remote Diode Digital Temperature Sensor: LM95245
Precision Remote Diode Digital Temperature Sensor: LM95245Precision Remote Diode Digital Temperature Sensor: LM95245
Precision Remote Diode Digital Temperature Sensor: LM95245
 
Conversor a d mcp3201
Conversor a d mcp3201Conversor a d mcp3201
Conversor a d mcp3201
 
ADC and DAC Best Ever Pers
ADC and DAC Best Ever PersADC and DAC Best Ever Pers
ADC and DAC Best Ever Pers
 
PIC Microcontroller
PIC MicrocontrollerPIC Microcontroller
PIC Microcontroller
 
rae_mic2_sensors_and_signals for study purposes
rae_mic2_sensors_and_signals for study purposesrae_mic2_sensors_and_signals for study purposes
rae_mic2_sensors_and_signals for study purposes
 
UP product catalog
UP product catalogUP product catalog
UP product catalog
 
UNIT 4 & 5 - I nterfacing_Lecture7.pptx
UNIT 4 & 5 - I         nterfacing_Lecture7.pptxUNIT 4 & 5 - I         nterfacing_Lecture7.pptx
UNIT 4 & 5 - I nterfacing_Lecture7.pptx
 
Datasheet de ICL7106 y ICL7107
Datasheet de ICL7106 y ICL7107Datasheet de ICL7106 y ICL7107
Datasheet de ICL7106 y ICL7107
 

Último

Connect Wave/ connectwave Pitch Deck Presentation
Connect Wave/ connectwave Pitch Deck PresentationConnect Wave/ connectwave Pitch Deck Presentation
Connect Wave/ connectwave Pitch Deck PresentationSlibray Presentation
 
SAP Build Work Zone - Overview L2-L3.pptx
SAP Build Work Zone - Overview L2-L3.pptxSAP Build Work Zone - Overview L2-L3.pptx
SAP Build Work Zone - Overview L2-L3.pptxNavinnSomaal
 
Ensuring Technical Readiness For Copilot in Microsoft 365
Ensuring Technical Readiness For Copilot in Microsoft 365Ensuring Technical Readiness For Copilot in Microsoft 365
Ensuring Technical Readiness For Copilot in Microsoft 3652toLead Limited
 
Unleash Your Potential - Namagunga Girls Coding Club
Unleash Your Potential - Namagunga Girls Coding ClubUnleash Your Potential - Namagunga Girls Coding Club
Unleash Your Potential - Namagunga Girls Coding ClubKalema Edgar
 
Powerpoint exploring the locations used in television show Time Clash
Powerpoint exploring the locations used in television show Time ClashPowerpoint exploring the locations used in television show Time Clash
Powerpoint exploring the locations used in television show Time Clashcharlottematthew16
 
DSPy a system for AI to Write Prompts and Do Fine Tuning
DSPy a system for AI to Write Prompts and Do Fine TuningDSPy a system for AI to Write Prompts and Do Fine Tuning
DSPy a system for AI to Write Prompts and Do Fine TuningLars Bell
 
What's New in Teams Calling, Meetings and Devices March 2024
What's New in Teams Calling, Meetings and Devices March 2024What's New in Teams Calling, Meetings and Devices March 2024
What's New in Teams Calling, Meetings and Devices March 2024Stephanie Beckett
 
Developer Data Modeling Mistakes: From Postgres to NoSQL
Developer Data Modeling Mistakes: From Postgres to NoSQLDeveloper Data Modeling Mistakes: From Postgres to NoSQL
Developer Data Modeling Mistakes: From Postgres to NoSQLScyllaDB
 
DevEX - reference for building teams, processes, and platforms
DevEX - reference for building teams, processes, and platformsDevEX - reference for building teams, processes, and platforms
DevEX - reference for building teams, processes, and platformsSergiu Bodiu
 
"Debugging python applications inside k8s environment", Andrii Soldatenko
"Debugging python applications inside k8s environment", Andrii Soldatenko"Debugging python applications inside k8s environment", Andrii Soldatenko
"Debugging python applications inside k8s environment", Andrii SoldatenkoFwdays
 
WordPress Websites for Engineers: Elevate Your Brand
WordPress Websites for Engineers: Elevate Your BrandWordPress Websites for Engineers: Elevate Your Brand
WordPress Websites for Engineers: Elevate Your Brandgvaughan
 
Vertex AI Gemini Prompt Engineering Tips
Vertex AI Gemini Prompt Engineering TipsVertex AI Gemini Prompt Engineering Tips
Vertex AI Gemini Prompt Engineering TipsMiki Katsuragi
 
Leverage Zilliz Serverless - Up to 50X Saving for Your Vector Storage Cost
Leverage Zilliz Serverless - Up to 50X Saving for Your Vector Storage CostLeverage Zilliz Serverless - Up to 50X Saving for Your Vector Storage Cost
Leverage Zilliz Serverless - Up to 50X Saving for Your Vector Storage CostZilliz
 
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024BookNet Canada
 
SIP trunking in Janus @ Kamailio World 2024
SIP trunking in Janus @ Kamailio World 2024SIP trunking in Janus @ Kamailio World 2024
SIP trunking in Janus @ Kamailio World 2024Lorenzo Miniero
 
Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?Mattias Andersson
 
CloudStudio User manual (basic edition):
CloudStudio User manual (basic edition):CloudStudio User manual (basic edition):
CloudStudio User manual (basic edition):comworks
 
Commit 2024 - Secret Management made easy
Commit 2024 - Secret Management made easyCommit 2024 - Secret Management made easy
Commit 2024 - Secret Management made easyAlfredo García Lavilla
 
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)Mark Simos
 

Último (20)

Connect Wave/ connectwave Pitch Deck Presentation
Connect Wave/ connectwave Pitch Deck PresentationConnect Wave/ connectwave Pitch Deck Presentation
Connect Wave/ connectwave Pitch Deck Presentation
 
SAP Build Work Zone - Overview L2-L3.pptx
SAP Build Work Zone - Overview L2-L3.pptxSAP Build Work Zone - Overview L2-L3.pptx
SAP Build Work Zone - Overview L2-L3.pptx
 
Ensuring Technical Readiness For Copilot in Microsoft 365
Ensuring Technical Readiness For Copilot in Microsoft 365Ensuring Technical Readiness For Copilot in Microsoft 365
Ensuring Technical Readiness For Copilot in Microsoft 365
 
Unleash Your Potential - Namagunga Girls Coding Club
Unleash Your Potential - Namagunga Girls Coding ClubUnleash Your Potential - Namagunga Girls Coding Club
Unleash Your Potential - Namagunga Girls Coding Club
 
Powerpoint exploring the locations used in television show Time Clash
Powerpoint exploring the locations used in television show Time ClashPowerpoint exploring the locations used in television show Time Clash
Powerpoint exploring the locations used in television show Time Clash
 
DSPy a system for AI to Write Prompts and Do Fine Tuning
DSPy a system for AI to Write Prompts and Do Fine TuningDSPy a system for AI to Write Prompts and Do Fine Tuning
DSPy a system for AI to Write Prompts and Do Fine Tuning
 
What's New in Teams Calling, Meetings and Devices March 2024
What's New in Teams Calling, Meetings and Devices March 2024What's New in Teams Calling, Meetings and Devices March 2024
What's New in Teams Calling, Meetings and Devices March 2024
 
Developer Data Modeling Mistakes: From Postgres to NoSQL
Developer Data Modeling Mistakes: From Postgres to NoSQLDeveloper Data Modeling Mistakes: From Postgres to NoSQL
Developer Data Modeling Mistakes: From Postgres to NoSQL
 
DevEX - reference for building teams, processes, and platforms
DevEX - reference for building teams, processes, and platformsDevEX - reference for building teams, processes, and platforms
DevEX - reference for building teams, processes, and platforms
 
"Debugging python applications inside k8s environment", Andrii Soldatenko
"Debugging python applications inside k8s environment", Andrii Soldatenko"Debugging python applications inside k8s environment", Andrii Soldatenko
"Debugging python applications inside k8s environment", Andrii Soldatenko
 
WordPress Websites for Engineers: Elevate Your Brand
WordPress Websites for Engineers: Elevate Your BrandWordPress Websites for Engineers: Elevate Your Brand
WordPress Websites for Engineers: Elevate Your Brand
 
Vertex AI Gemini Prompt Engineering Tips
Vertex AI Gemini Prompt Engineering TipsVertex AI Gemini Prompt Engineering Tips
Vertex AI Gemini Prompt Engineering Tips
 
Leverage Zilliz Serverless - Up to 50X Saving for Your Vector Storage Cost
Leverage Zilliz Serverless - Up to 50X Saving for Your Vector Storage CostLeverage Zilliz Serverless - Up to 50X Saving for Your Vector Storage Cost
Leverage Zilliz Serverless - Up to 50X Saving for Your Vector Storage Cost
 
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
 
SIP trunking in Janus @ Kamailio World 2024
SIP trunking in Janus @ Kamailio World 2024SIP trunking in Janus @ Kamailio World 2024
SIP trunking in Janus @ Kamailio World 2024
 
Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?
 
E-Vehicle_Hacking_by_Parul Sharma_null_owasp.pptx
E-Vehicle_Hacking_by_Parul Sharma_null_owasp.pptxE-Vehicle_Hacking_by_Parul Sharma_null_owasp.pptx
E-Vehicle_Hacking_by_Parul Sharma_null_owasp.pptx
 
CloudStudio User manual (basic edition):
CloudStudio User manual (basic edition):CloudStudio User manual (basic edition):
CloudStudio User manual (basic edition):
 
Commit 2024 - Secret Management made easy
Commit 2024 - Secret Management made easyCommit 2024 - Secret Management made easy
Commit 2024 - Secret Management made easy
 
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
 

EEP-EnOcean Profiles v02.00

  • 1. EnOcean Equipment Profiles No Wires. No Batteries. No Limits 06 Enero 2010
  • 2.
  • 4. EnOcean Telegrams types – ORG EEP and Data payload Definition The EEP is defined as following: ORG – FUNC (profile) – TYPE Ranges: ORG 0x00 … 0xFF FUNC 0x00 … 0x3F TYPE 0x00 … 0x7F
  • 5.
  • 6. EnOcean Equipment Profiles – ORG 5 – ORG 6 i.e STM250-Wireless window contact 06-00-01 01-Single Input Contact 00-Contacts & Switches ORG 6 1BS Telegram   05-10-00 00-Window Handle 10-Mechanical Handle     tbd 05-Position Switch, Industrial Application Insertion of Key Card generates an N-Message, take-out a U-Message 05-04-01 01-Key Card Activated Switch 04-Position Switch, Home and Office application This EEP definition is based on the assumption that a RPS switch module (e.g. PTM200) is installed in an I-STATE up position! Application Style 2 is typically used in US and CAN but may be found in other markets as well. 05-03-02 02-Light and Blind Control-Application Style 2   This EEP definition is based on the assumption that a RPS switch module (e.g. PTM200) is installed in a 0-STATE up position! Application Style 1 is widely used in EU but may be found in other markets as well. 05-03-01 01-Light and Blind Control-Application Style 1 03-Rocker Switch 4 rocker This EEP definition is based on the assumption that a RPS switch module (e.g. PTM200) is installed in an I-STATE up position! Application Style 2 is typically used in US and CAN but may be found in other markets as well. 05-02-02 02-Light and Blind Control-Application Style 2   This EEP definition is based on the assumption that a RPS switch module (e.g. PTM200) is installed in a 0-STATE up position! Application Style 1 is widely used in EU but may be found in other markets as well. 05-02-01 01-Light and Blind Control-Application Style 1 02-Rocker Switch 2 rocker Comments EEP TYPE FUNCTION -PROFILE ORG 5 RPS Telegram
  • 7. EEP – ORG 7 – 4BS – Function 2 DB_1: Temperature, linear n=255…0 07-02-1B 1B-Range +50ºC to +130ºC DB_1: Temperature, linear n=255…0 07-02-1A 1A-Range +40ºC to +120ºC DB_1: Temperature, linear n=255…0 07-02-19 19-Range +30ºC to +110ºC DB_1: Temperature, linear n=255…0 07-02-18 18-Range +20ºC to +100ºC DB_1: Temperature, linear n=255…0 07-02-17 17-Range +10ºC to +90ºC DB_1: Temperature, linear n=255…0 07-02-16 16-Range 0ºC to +80ºC DB_1: Temperature, linear n=255…0 07-02-15 15-Range -10ºC to +70ºC DB_1: Temperature, linear n=255…0 07-02-14 14-Range -20ºC to +60ºC DB_1: Temperature, linear n=255…0 07-02-13 13-Range -30ºC to +50ºC DB_1: Temperature, linear n=255…0 07-02-12 12-Range -40ºC to +40ºC DB_1: Temperature, linear n=255…0 07-02-11 11-Range -50ºC to +30ºC DB_1: Temperature, linear n=255…0 07-02-10 10-Range -60ºC to +20ºC DB_1: Temperature, linear n=255…0 07-02-0B 0B-Range +60ºC to +100ºC DB_1: Temperature, linear n=255…0 07-02-0A 0A-Range +50ºC to +90ºC DB_1: Temperature, linear n=255…0 07-02-09 09-Range +40ºC to +80ºC DB_1: Temperature, linear n=255…0 07-02-08 08-Range +30ºC to +70ºC DB_1: Temperature, linear n=255…0 07-02-07 07-Range +20ºC to +60ºC DB_1: Temperature, linear n=255…0 07-02-06 06-Range +10ºC to +50ºC DB_1: Temperature, linear n=255…0 07-02-05 05-Range 0ºC to +40ºC DB_1: Temperature, linear n=255…0 07-02-04 04-Range -10ºC to +30ºC DB_1: Temperature, linear n=255…0 07-02-03 03-Range -20ºC to +20ºC DB_1: Temperature, linear n=255…0 07-02-02 02-Range -30ºC to +10ºC DB_1: Temperature, linear n=255…0 07-02-01 01-Range -40ºC to 0ºC 02-Temperature Sensor Comments EEP TYPE FUNCTION -PROFILE ORG 7 4BS Telegram
  • 8. EEP – ORG 7 – 4BS – Functions 4…9 tbd 07-09-0C 0C-Propane Sensor tbd 07-09-08 08-O2 Sensor tbd 07-09-04 04-CO2 Sensor   07-09-01 01-CO Sensor 09-Gas Sensor DB_3: Supply voltage 0…5,1V, linear n=0…255 DB_2: Illuminance 0…1530lx, linear n=255…0 DB_1: Temperature -30…50ºC, linear n=255…0 07-08-02 02-Range 0lx to 1530lx -30ºC to +50ºC and Occupancy DB_3: Supply voltage 0…5,1V, linear n=0…255 DB_2: Illuminance 0…1020lx, linear n=255…0 DB_1: Temperature 0…51ºC, linear n=255…0 07-08-02 02-Range 0lx to 1020lx 0ºC to +51ºC and Occupancy DB_3: Supply voltage 0…5,1V, linear n=0…255 DB_2: Illuminance 0…510lx, linear n=255…0 DB_1: Temperature 0…51ºC, linear n=255…0 07-08-01 01-Range 0lx to 510lx 0ºC to +51ºC and Occupancy 08-Light, Temperature&Occupancy Sensor DB_1: PIR Status 0…127 PIR off, 127…255 PIR on The transmission of "PIR off" telegrams is optional 07-07-01 01-Occupancy 07-Occupancy Sensor DB_3: Supply voltage 0…5,1V, linear n=0…255 DB_2: Illuminance 0…510lx, linear n=255…0 DB_1: Illuminance 0…1.024lx, linear n=255…0 07-06-02 02-Range 0lx to 1.024lx DB_3: Supply voltage 0…5,1V, linear n=0…255 DB_2: Illuminance 300…30.000lx, linear n=255…0 DB_1: Illuminance 600…60.000lx, linear n=255…0 07-06-01 01-Range 300lx to 60.000lx 06-Light Sensor     tbd 05-Pressure Sensor DB_2: Rel. Humidity 0…100%, linear n=255…0 DB_1: Temperature, 0…40ºC, linear n=255…0 07-04-01 01-Range 0ºC to +40ºC and 0% to 100% 04-Temperature & Humidity Sensor Comments EEP TYPE FUNCTION -PROFILE ORG 7 4BS Telegram
  • 9. EEP – ORG 7 – 4BS – Function 10 DB_3: Turn-switch for fan speed DB_1: Temperature, 0…40ºC, linear n=255…0 DB_0.bit_0: Slide switch O/I, Day/Night 07-10-09 09-Temperature Sensor, Fan Speed and Day/Night Control DB_3: Turn-switch for fan speed DB_1: Temperature, 0…40ºC, linear n=255…0 DB_0.bit_0: Occupancy button 07-10-08 08-Temperature Sensor, Fan Speed and Ocuppancy Control DB_3: Turn-switch for fan speed DB_1: Temperature, 0…40ºC, linear n=255…0 07-10-07 07-Temperature Sensor, Fan Speed Control DB_2: Set point, min…max +, linear n=0…255 DB_1: Temperature, 0…40ºC, linear n=255…0 DB_0.bit_0: Slide switch O/I, Day/Night 07-10-06 06-Temperature Sensor, set point and Day/Night Control DB_2: Set point, min…max +, linear n=0…255 DB_1: Temperature, 0…40ºC, linear n=255…0 DB_0.bit_0: Slide switch O/I, Day/Night 07-10-05 05-Temperature Sensor, set point and Occupancy Control DB_3: Turn-switch for fan speed DB_2: Set point, min…max +, linear n=0…255 DB_1: Temperature, 0…40ºC, linear n=255…0 07-10-04 04-Temperature Sensor, set point and Fan Speed Control DB_2: Set point, min…max +, linear n=0…255 DB_1: Temperature, 0…40ºC, linear n=255…0 07-10-03 03-Temperature Sensor, set point control DB_3: Turn-switch for fan speed DB_2: Set point, min…max +, linear n=0…255 DB_1: Temperature, 0…40ºC, linear n=255…0 DB_0.bit_0: Slide switch O/I, Day/Night 07-10-02 02-Temperature Sensor, set point, Fan Speed and Day/Night Control DB_3: Turn-switch for fan speed DB_2: Set point, min…max +, linear n=0…255 DB_1: Temperature, 0…40ºC, linear n=255…0 DB_0.bit_0: Occupancy button 07-10-01 01-Temperature Sensor, set point, Fan Speed and Ocuppancy Control 10-Room Operating Panel Comments EEP TYPE FUNCTION -PROFILE ORG 7 4BS Telegram
  • 10. EEP – ORG 7 – 4BS – Function 10 DB_2: Rel. Humidity 0…100%, linear n=0…250 DB_1: Temperature, 0…40ºC, linear n=0…250 DB_0.bit_0: Slide Switch 0/I or Slide switch Day/Night 07-10-14 14-Temperature and Humidity Sensor, Day/Night Control DB_2: Rel. Humidity 0…100%, linea nr=0…250 DB_1: Temperature, 0…40ºC, linear n=0…250 DB_0.bit_0: Occupancy button 07-10-13 13-Temperature and Humidity Sensor, Occupancy Control DB_3: Set point, min…max +, linear n=0…255 DB_2: Rel. Humidity 0…100%, linear n=0…250 DB_1: Temperature, 0…40ºC, linear n=0…250 07-10-12 12-Temperature and Humidity Sensor, set point Control DB_3: Set point, min…max +, linear n=0…255 DB_2: Rel. Humidity 0…100%, linear n=0…250 DB_1: Temperature, 0…40ºC, linear n=0…250 DB_0.bit_0: Slide Switch 0/I or Slide switch Day/Night 07-10-11 11-Temperature and Humidity Sensor, set point and Day/Night Control DB_3: Set point, min…max +, linear n=0…255 DB_2: Rel. Humidity 0…100%, linear n=0…250 DB_1: Temperature, 0…40ºC, linear n=0…250 DB_0.bit_0: Ocuupancy button 07-10-10 10-Temperature and Humidity Sensor, set point and Occupancy Control DB_1: Temperature, 0…40ºC, linear n=255…0 DB_0.bit_0: Slide switch 07-10-0D 0D-Temperature Sensor and Day/Night Control DB_1: Temperature, 0…40ºC, linear n=255…0 DB_0.bit_0: Occupancy 07-10-0C 0C-Temperature Sensor and Occupancy Control DB_1: Temperature, 0…40ºC, linear n=255…0 DB_0.bit_0: Input State 07-10-0B 0B-Temperature Sensor and Single Input Contact DB_2: Set point, min…max +, linear n=0…255 DB_1: Temperature, 0…40ºC, linear n=255…0 DB_0.bit_0: Contact State 07-10-0A 0A-Temperature Sensor, Set Point Adjust and Single Input Contact 10-Room Operating Panel Comments EEP TYPE FUNCTION -PROFILE ORG 7 4BS Telegram
  • 11. EEP – ORG 7 – 4BS – Functions 11, 30, 38, 3F This profile is intended for manufacturer specific applications. Every manufacturer may independently define the types within this profile. 07-3F-7F 7F-Universal 3F-Universal Commands 0x8x to 0xFE are not used 07-38-08 08-PHC Gateway DB_3: Command 0h02 dimming value, ramping time, dimming range, store final value…   Dimming DB_3: Command 0h01 time, delay…   Switching 38-Central Command (0h01…0h7F) DB_0.bit0: Input State 07-30-02 02-Single Input Contact DB_2: Supply voltage 0…120 battery LOW, 121…255 battery OK DB_1: Input State, 0…195 contact closed, 196…255 Contact open 07-30-01 01-Single Input, Battery Monitor 30-Digital Input DB_3: Illuminance 0...510lx, linear n=0…255 DB_2: Illuminance set point, min...max, linear n=0…255 DB_1: Dimming output level, min...max, linear n=0…255 DB_0.bit_7: Repeater DB_0.bit_6: Power Relay Timer DB_0.bit_5: Daylight Harvesting DB_0.bit_4: Dimming DB_0.bit_2: Magnet Contact DB_0.bit_1: Occupancy DB_0.bit_0: Power Relay 07-11-01 01-Lighting Controller 11-Controller Status Comments EEP TYPE FUNCTION -PROFILE ORG 7 4BS Telegram