SlideShare una empresa de Scribd logo
1 de 36
Technical Seminar Report on
BASE ISOLATION CONCEPT AND
TECHNIQUES
BY
M. PREM SAI
11H61A0135
DEPARTMENT OF CIVIL ENGINEERING
ANURAG GROUP OF INSTITUTIONS, VENKATAPUR,
HYDERABAD
CONTENTS
 INTRODUCTION
 BASE ISOLATION
 CONCEPT OF BASE ISOLATION
 PRINCIPLE OF BASE ISOLATION
 SUITABILITY OF BASE ISOLATION
 FIXED BASE STRUCTURE VS ISOLATED
BASE STRUCTURE
 ISOLATION COMPONENTS
 ISOLATOR LOCATIONS
 IN REAL SCENARIO
 APPLICATIONS
 CONCLUSION
1. INTRODUCTION
 Earthquake by itself, is not a disaster, it is natural phenomenon
result from ground movement, sometimes violent.
 These produce surface waves, which cause vibration of the
ground and structures standing on top.
 Depending on the characteristics of these vibrations, the
ground may develop cracks, fissures and settlements.
 The possible risk of loss of life adds a very serious dimension to
seismic design, putting a moral responsibility on structural
engineers.
 In recent times, many new systems have been developed,
either to reduce the earthquake forces acting on the
structure or to absorb a part of seismic energy.
 One of the most widely implemented and accepted seismic
protection systems is base isolation.
1. INTRODUCTION
2. BASE ISOLATION
 Base isolation is one of the most widely accepted seismic
protection systems in earthquake prone areas.
 It mitigates the effect of an earthquake by essentially
isolating the structure from potentially dangerous ground
motions.
 Seismic isolation is a design strategy, which uncouples the
structure for the damaging effects of the ground motion.
 The term isolation refers to reduced interaction between structure
and the ground.
 When the seismic isolation system is located under the structure, it is
referred as “base isolation”.
 The other purpose of an isolation system is to provide an additional
means of energy dissipation, thereby reducing the transmitted
acceleration into the superstructure.
 The decoupling allows the building to behave more flexibly which
improves its response to an earthquake.
2. BASE ISOLATION
3. CONCEPT OF BASE ISOLATION
 The concept of base isolation is explained through an
example building resting on frictionless rollers.
 When the ground shakes, the rollers freely roll, but the building
above does not move.
 Thus, no force is transferred to the building due to shaking of
the ground; simply, the building does not experience the
earthquake.
3. CONCEPT OF BASE ISOLATION
 Now, if the same building is rested on flexible pads that offer
resistance against lateral movements, then some effect of
the ground shaking will be transferred to the building above.
 The flexible pads are called base-isolators, whereas the
structures protected by means of these devices are called
base-isolated buildings.
 The main feature of the base isolation technology is that it
introduces flexibility in the structure.
3. CONCEPT OF BASE ISOLATION
3. CONCEPT OF BASE ISOLATION
 A careful study is required to identify the most suitable type
of device for a particular building.
 Also, base isolation is not suitable for all buildings.
 Most suitable structures for base-isolation are
 Low to medium-rise buildings rested on hard soil underneath
 High-rise buildings or buildings rested on soft soil are not
suitable for base isolation.
3. CONCEPT OF BASE ISOLATION
4. PRINCIPLE OF BASE ISOLATION
 The fundamental principle of base isolation is to modify the
response of the building so that the ground can move below
the building without transmitting these motions into the building.
 A building that is perfectly rigid will have a zero period.
 When the ground moves the acceleration induced in the
structure will be equal to the ground acceleration and there
will be zero relative displacement between the structure and
the ground.
 The structure and ground move the same amount.
 A building that is perfectly flexible will have an infinite
period.
 For this type of structure, when the ground beneath the
structure moves there will be zero acceleration induced in
the structure and the relative displacement between the
structure and ground will be equal to the ground
displacement.
4. PRINCIPLE OF BASE ISOLATION
 So in flexible structures the structure will not move, the
ground will.
4. PRINCIPLE OF BASE ISOLATION
5. SUITABILITY OF BASE ISOLATION
 Earthquake protection of structures using base isolation technique
is generally suitable if the following conditions are fulfilled
 The subsoil does not produce a predominance of long period ground
motion.
 The structure is fairly jointed with sufficiently high column load.
 The site permits horizontal displacements at the base of the order of 200
mm or more.
 Lateral loads due to wind are less than approximately 10% of the weight
of the structure.
6. Fixed Base Structure vs Isolated Base
Structure
 During earthquakes, the conventional structure without seismic
isolation is subjected to substantial story drifts, which may lead to
damage or even collapse of the building.
 Whereas the isolated structure vibrates almost like a rigid body with
large deformations or displacements restricted by the isolation
bearings.
 The decoupling effect gives this extra advantange to isolated
structures.
 The lateral forces of the isolated building are not only
reduced in magnitude but also fairly redistributed over the
floors, which further mitigates the overturning moment of the
structure.
6. Fixed Base Structure vs Isolated Base Structure
6. Fixed Base Structure vs Isolated Base Structure
7. ISOLATION COMPONENTS
 Elastomeric Isolators
 Natural Rubber Bearings
 Low-Damping Rubber Bearings
 Lead-Rubber Bearings
 High-Damping Rubber Bearings
 Sliding Isolators
 Resilient Friction System
 Friction Pendulum System
 Elastomeric Isolators
 These are formed of horizontal layers of natural or synthetic
rubber in thin layers bonded between steel plates.
 The steel plates prevent the rubber layers from bulging and so
the bearing is able to support higher vertical loads with only
small deformations.
 Plain elastomeric bearings provide flexibility but no significant
damping and will move under service loads.
7. ISOLATION COMPONENTS
 Methods used to overcome these deficits include lead cores in the
bearing, specially formulated elastomers with high damping and
stiffness for small strains or other devices in parallel.
7. ISOLATION COMPONENTS
 Low Damping Natural or Synthetic Rubber Bearings
 Elastomeric bearings use either natural rubber or synthetic
rubber (such as neoprene), which have little inherent damping,
usually 2% to 3% of critical viscous damping.
 For isolation they are generally used with special elastomer
compounds (high damping rubber bearings) or in combination
with other devices (lead rubber bearings).
 They are also flexible at all strain levels.
7. ISOLATION COMPONENTS
 Lead Rubber Bearings
 A lead-rubber bearing is formed of a lead plug force-fitted into
a pre-formed hole in an elastomeric bearing.
 The lead core provides rigidity under service loads and energy
dissipation under high lateral loads.
 Top and bottom steel plates, thicker than the internal shims, are
used to accommodate mounting hardware. The entire bearing
is encased in cover rubber to provide environmental protection.
7. ISOLATION COMPONENTS
 When subjected to low lateral loads
(such as minor earthquake, wind or
traffic loads) the lead rubber bearing is
stiff both laterally and vertically.
 The lateral stiffness results from the high
elastic stiffness of the lead plug and the
vertical rigidity (which remains at all
load levels) results from the steel-rubber
construction of the bearing.
7. ISOLATION COMPONENTS
 Isolation Systems based on Sliding
 The second most common type of isolation system uses sliding
elements between the foundation and base of the structure.
 In this type of Isolation system, the sliding displacements are
controlled by high-tension springs or laminated rubber bearings,
or by making the sliding surface curved.
 These mechanisms provide a restoring force to return the
structure to its equilibrium position.
7. ISOLATION COMPONENTS
 Sliding isolator without Recentering capacity
 This consists of a horizontal sliding surface,
allowing a displacement and thus dissipating
energy by means of defined friction between
both sliding components and stainless steel.
 One particular problem with a sliding
structure is the residual displacements that
occur after major earthquakes.
7. ISOLATION COMPONENTS
 Sliding Isolator with Recentering Capacity
 Compared with sliding isolators, sliding isolation pendula (SIPs)
with recentering capacity have a concave sliding plate.
 Due to geometry, each horizontal displacement results in a
vertical movement of the isolator.
 The potential energy, stored by the superstructure, which has
been pushed to the top, automatically results in recentering the
bearing into neutral position.
7. ISOLATION COMPONENTS
 They remain horizontally flexible, dissipate energy and
recenter the superstructure into neutral position.
7. ISOLATION COMPONENTS
 Friction Pendulum System
 The Friction pendulum system (FPS) is a sliding isolation system
wherein the weight of the structure is supported on spherical
sliding surfaces that slide relative to each other when the
ground motion exceeds a threshold level.
7. ISOLATION COMPONENTS
8. Isolator Locations
 The requirement for installation of a base isolation system is
that the building be able to move horizontally relative to the
ground, usually at least 100 mm.
 The most common configuration is to install a diaphragm
immediately above the isolators.
 If the building has a basement then the options are to install
the isolators at the top, bottom or mid-height of the
basements columns and walls.
8. Isolator Locations
9. BASE ISOLATION IN REAL BUILDINGS
 Seismic isolation is a relatively recent and evolving
technology. It has been in increased use since the 1980s, and
has been well evaluated and reviewed internationally.
 Base isolation is also useful for retrofitting important buildings
(like hospitals and historic buildings).
 By now, over 1000 buildings across the world have been
equipped with seismic base isolation.
 In India, base isolation technique was first demonstrated after
the 1993 Killari (Maharashtra) Earthquake.
 Two single storey buildings in newly relocated Killari town were
built with rubber base isolators resting on hard ground.
 After the 2001 Bhuj (Gujarat) earthquake, the four-storey Bhuj
Hospital building was built with base isolation technique.
 All were brick masonry buildings with concrete roof.
9. BASE ISOLATION IN REAL BUILDINGS
 The figure shows the base isolation technique used in the Bhuj
Hospital building with the help of Base Isolators.
9. BASE ISOLATION IN REAL BUILDINGS
10. APPLICATIONS
 Base isolation provides an alternative to the conventional,
fixed base design of structures.
 Base Isolation minimizes the need for strengthening measures
of adding shear walls, frames, and bracing by reducing the
earthquake forces imparted to the building.
 Base isolation had the effect of reducing the earthquake
force demands on the superstructure to 30% of the demands
for a fixed-base structure.
11. CONCLUSION
 Seismic base isolation method has proved to be a reliable method of
earthquake resistant Design.
 The success of this method is largely attributed to the development
of isolation devices and proper planning.
 Adaptable isolation systems are required to be effective during a
wide range of seismic events.
 Efforts are required to find the solutions for the situations like near
fault regions where wide variety of earthquake motions may occur.

Más contenido relacionado

La actualidad más candente

Buildings with base isolation techniques pic
Buildings with base isolation techniques picBuildings with base isolation techniques pic
Buildings with base isolation techniques picAkshay Raut
 
Diaphragm walls
Diaphragm wallsDiaphragm walls
Diaphragm wallsNeha Vivek
 
Report on Study on Base Isolation Techniques.
Report on Study on Base Isolation Techniques.Report on Study on Base Isolation Techniques.
Report on Study on Base Isolation Techniques.Gaurav Mewara
 
Base isolation and its Application By Mukesh Singh Ghuraiya
Base isolation and its Application By Mukesh Singh GhuraiyaBase isolation and its Application By Mukesh Singh Ghuraiya
Base isolation and its Application By Mukesh Singh GhuraiyaMukesh Singh Ghuraiya
 
Project ppt on earthquake resistant building structure
Project ppt on earthquake resistant building structureProject ppt on earthquake resistant building structure
Project ppt on earthquake resistant building structureSambhavJain168
 
Earthquake resistant building construction
Earthquake resistant building constructionEarthquake resistant building construction
Earthquake resistant building constructiondaspriyabrata3
 
Base isolation techniques-Earthquake Engineering
Base isolation techniques-Earthquake EngineeringBase isolation techniques-Earthquake Engineering
Base isolation techniques-Earthquake EngineeringGokul Ayyappan
 
Safe Built Environment
Safe Built EnvironmentSafe Built Environment
Safe Built Environmentguest674fa
 
Ductile detailing IS 13920
Ductile detailing IS 13920Ductile detailing IS 13920
Ductile detailing IS 13920INTEZAAR ALAM
 
Earthquake resistent building construction ppt
Earthquake resistent building construction pptEarthquake resistent building construction ppt
Earthquake resistent building construction pptDiptiranjan Mohapatra
 
Earthquake resistance structures
Earthquake resistance structuresEarthquake resistance structures
Earthquake resistance structuresUday kumar Devalla
 
EARTHQUAKE RESISTANT STRUCTURES
EARTHQUAKE RESISTANT STRUCTURESEARTHQUAKE RESISTANT STRUCTURES
EARTHQUAKE RESISTANT STRUCTUREShemanthchintu135
 
PERFORMANCE BASED ANALYSIS OF VERTICALLY IRREGULAR STRUCTURE UNDER VARIOUS SE...
PERFORMANCE BASED ANALYSIS OF VERTICALLY IRREGULAR STRUCTURE UNDER VARIOUS SE...PERFORMANCE BASED ANALYSIS OF VERTICALLY IRREGULAR STRUCTURE UNDER VARIOUS SE...
PERFORMANCE BASED ANALYSIS OF VERTICALLY IRREGULAR STRUCTURE UNDER VARIOUS SE...Ijripublishers Ijri
 

La actualidad más candente (20)

Buildings with base isolation techniques pic
Buildings with base isolation techniques picBuildings with base isolation techniques pic
Buildings with base isolation techniques pic
 
Dampness
DampnessDampness
Dampness
 
Limit state method
Limit state methodLimit state method
Limit state method
 
Diaphragm walls
Diaphragm wallsDiaphragm walls
Diaphragm walls
 
Report on Study on Base Isolation Techniques.
Report on Study on Base Isolation Techniques.Report on Study on Base Isolation Techniques.
Report on Study on Base Isolation Techniques.
 
Base isolation and its Application By Mukesh Singh Ghuraiya
Base isolation and its Application By Mukesh Singh GhuraiyaBase isolation and its Application By Mukesh Singh Ghuraiya
Base isolation and its Application By Mukesh Singh Ghuraiya
 
Project ppt on earthquake resistant building structure
Project ppt on earthquake resistant building structureProject ppt on earthquake resistant building structure
Project ppt on earthquake resistant building structure
 
Earthquake resistant building construction
Earthquake resistant building constructionEarthquake resistant building construction
Earthquake resistant building construction
 
Base isolation techniques-Earthquake Engineering
Base isolation techniques-Earthquake EngineeringBase isolation techniques-Earthquake Engineering
Base isolation techniques-Earthquake Engineering
 
Different types of pile
Different types of pile Different types of pile
Different types of pile
 
earthquake resistant ppt
earthquake resistant pptearthquake resistant ppt
earthquake resistant ppt
 
Safe Built Environment
Safe Built EnvironmentSafe Built Environment
Safe Built Environment
 
Ductile detailing IS 13920
Ductile detailing IS 13920Ductile detailing IS 13920
Ductile detailing IS 13920
 
Concrete repair
Concrete repairConcrete repair
Concrete repair
 
Earthquake resistent building construction ppt
Earthquake resistent building construction pptEarthquake resistent building construction ppt
Earthquake resistent building construction ppt
 
Earthquake resistance structures
Earthquake resistance structuresEarthquake resistance structures
Earthquake resistance structures
 
EARTHQUAKE RESISTANT STRUCTURES
EARTHQUAKE RESISTANT STRUCTURESEARTHQUAKE RESISTANT STRUCTURES
EARTHQUAKE RESISTANT STRUCTURES
 
Ductile detailing
Ductile detailingDuctile detailing
Ductile detailing
 
PERFORMANCE BASED ANALYSIS OF VERTICALLY IRREGULAR STRUCTURE UNDER VARIOUS SE...
PERFORMANCE BASED ANALYSIS OF VERTICALLY IRREGULAR STRUCTURE UNDER VARIOUS SE...PERFORMANCE BASED ANALYSIS OF VERTICALLY IRREGULAR STRUCTURE UNDER VARIOUS SE...
PERFORMANCE BASED ANALYSIS OF VERTICALLY IRREGULAR STRUCTURE UNDER VARIOUS SE...
 
Shear wall and its design guidelines
Shear wall and its design guidelinesShear wall and its design guidelines
Shear wall and its design guidelines
 

Similar a Base isolation

vibration isolation
vibration isolationvibration isolation
vibration isolationpatilshiv407
 
BASIC ISOLATION TECHNIQUE.pptx
BASIC ISOLATION TECHNIQUE.pptxBASIC ISOLATION TECHNIQUE.pptx
BASIC ISOLATION TECHNIQUE.pptxRahulKumar964014
 
Microsoft Word - BASE ISOLATION
Microsoft Word - BASE ISOLATIONMicrosoft Word - BASE ISOLATION
Microsoft Word - BASE ISOLATIONSumit Srivastav
 
advanced construction technology - seismic isolation & passive-energy dissipa...
advanced construction technology - seismic isolation & passive-energy dissipa...advanced construction technology - seismic isolation & passive-energy dissipa...
advanced construction technology - seismic isolation & passive-energy dissipa...nagham ali hasan
 
BASE ISOLATION SYSTEM
BASE ISOLATION SYSTEMBASE ISOLATION SYSTEM
BASE ISOLATION SYSTEMSyed Jaber
 
Eatrhquake response of reinforced cocrete multi storey building with base iso...
Eatrhquake response of reinforced cocrete multi storey building with base iso...Eatrhquake response of reinforced cocrete multi storey building with base iso...
Eatrhquake response of reinforced cocrete multi storey building with base iso...eSAT Journals
 
Base isolation.ppt [Autosaved] [Autosaved]
Base isolation.ppt [Autosaved] [Autosaved]Base isolation.ppt [Autosaved] [Autosaved]
Base isolation.ppt [Autosaved] [Autosaved]Sumit Srivastav
 
Earthquake resisting building....isolated bearing
Earthquake resisting building....isolated bearingEarthquake resisting building....isolated bearing
Earthquake resisting building....isolated bearingAshish Mangal
 
Earthquake resistance in buildings
Earthquake resistance in buildingsEarthquake resistance in buildings
Earthquake resistance in buildingsRithika Ravishankar
 
Review on Base Isolated Structures
Review on Base Isolated StructuresReview on Base Isolated Structures
Review on Base Isolated StructuresIRJET Journal
 
Base isolation earthquake resistance wooden house
Base isolation earthquake resistance wooden houseBase isolation earthquake resistance wooden house
Base isolation earthquake resistance wooden houseTwinkal Jambu
 
Seismic Retrofitting and repairs and rehabilitations
Seismic Retrofitting and repairs and rehabilitationsSeismic Retrofitting and repairs and rehabilitations
Seismic Retrofitting and repairs and rehabilitationsKumarS250747
 
IRJET- Study of Base Isolated Building
IRJET- Study of Base Isolated BuildingIRJET- Study of Base Isolated Building
IRJET- Study of Base Isolated BuildingIRJET Journal
 
seismic control of structure
seismic control of structureseismic control of structure
seismic control of structurefazalrahman rang
 
Base isolation and damping
Base isolation and dampingBase isolation and damping
Base isolation and dampingmayur280524
 
Earthquake resistant structure
Earthquake resistant structureEarthquake resistant structure
Earthquake resistant structureVikrant Sabat
 

Similar a Base isolation (20)

vibration isolation
vibration isolationvibration isolation
vibration isolation
 
BASIC ISOLATION TECHNIQUE.pptx
BASIC ISOLATION TECHNIQUE.pptxBASIC ISOLATION TECHNIQUE.pptx
BASIC ISOLATION TECHNIQUE.pptx
 
Base isolation
Base isolationBase isolation
Base isolation
 
Microsoft Word - BASE ISOLATION
Microsoft Word - BASE ISOLATIONMicrosoft Word - BASE ISOLATION
Microsoft Word - BASE ISOLATION
 
advanced construction technology - seismic isolation & passive-energy dissipa...
advanced construction technology - seismic isolation & passive-energy dissipa...advanced construction technology - seismic isolation & passive-energy dissipa...
advanced construction technology - seismic isolation & passive-energy dissipa...
 
BASE ISOLATION SYSTEM
BASE ISOLATION SYSTEMBASE ISOLATION SYSTEM
BASE ISOLATION SYSTEM
 
Earthquick rasistant structure
Earthquick rasistant structureEarthquick rasistant structure
Earthquick rasistant structure
 
Eatrhquake response of reinforced cocrete multi storey building with base iso...
Eatrhquake response of reinforced cocrete multi storey building with base iso...Eatrhquake response of reinforced cocrete multi storey building with base iso...
Eatrhquake response of reinforced cocrete multi storey building with base iso...
 
Base isolation.ppt [Autosaved] [Autosaved]
Base isolation.ppt [Autosaved] [Autosaved]Base isolation.ppt [Autosaved] [Autosaved]
Base isolation.ppt [Autosaved] [Autosaved]
 
Earthquake resisting building....isolated bearing
Earthquake resisting building....isolated bearingEarthquake resisting building....isolated bearing
Earthquake resisting building....isolated bearing
 
Earthquake Fuse
Earthquake FuseEarthquake Fuse
Earthquake Fuse
 
Earthquake resistance in buildings
Earthquake resistance in buildingsEarthquake resistance in buildings
Earthquake resistance in buildings
 
Review on Base Isolated Structures
Review on Base Isolated StructuresReview on Base Isolated Structures
Review on Base Isolated Structures
 
Synopsis tit
Synopsis titSynopsis tit
Synopsis tit
 
Base isolation earthquake resistance wooden house
Base isolation earthquake resistance wooden houseBase isolation earthquake resistance wooden house
Base isolation earthquake resistance wooden house
 
Seismic Retrofitting and repairs and rehabilitations
Seismic Retrofitting and repairs and rehabilitationsSeismic Retrofitting and repairs and rehabilitations
Seismic Retrofitting and repairs and rehabilitations
 
IRJET- Study of Base Isolated Building
IRJET- Study of Base Isolated BuildingIRJET- Study of Base Isolated Building
IRJET- Study of Base Isolated Building
 
seismic control of structure
seismic control of structureseismic control of structure
seismic control of structure
 
Base isolation and damping
Base isolation and dampingBase isolation and damping
Base isolation and damping
 
Earthquake resistant structure
Earthquake resistant structureEarthquake resistant structure
Earthquake resistant structure
 

Último

CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdfCCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdfAsst.prof M.Gokilavani
 
Heart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptxHeart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptxPoojaBan
 
Work Experience-Dalton Park.pptxfvvvvvvv
Work Experience-Dalton Park.pptxfvvvvvvvWork Experience-Dalton Park.pptxfvvvvvvv
Work Experience-Dalton Park.pptxfvvvvvvvLewisJB
 
An introduction to Semiconductor and its types.pptx
An introduction to Semiconductor and its types.pptxAn introduction to Semiconductor and its types.pptx
An introduction to Semiconductor and its types.pptxPurva Nikam
 
Concrete Mix Design - IS 10262-2019 - .pptx
Concrete Mix Design - IS 10262-2019 - .pptxConcrete Mix Design - IS 10262-2019 - .pptx
Concrete Mix Design - IS 10262-2019 - .pptxKartikeyaDwivedi3
 
Call Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call GirlsCall Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call Girlsssuser7cb4ff
 
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...srsj9000
 
CCS355 Neural Networks & Deep Learning Unit 1 PDF notes with Question bank .pdf
CCS355 Neural Networks & Deep Learning Unit 1 PDF notes with Question bank .pdfCCS355 Neural Networks & Deep Learning Unit 1 PDF notes with Question bank .pdf
CCS355 Neural Networks & Deep Learning Unit 1 PDF notes with Question bank .pdfAsst.prof M.Gokilavani
 
Churning of Butter, Factors affecting .
Churning of Butter, Factors affecting  .Churning of Butter, Factors affecting  .
Churning of Butter, Factors affecting .Satyam Kumar
 
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdfCCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdfAsst.prof M.Gokilavani
 
Electronically Controlled suspensions system .pdf
Electronically Controlled suspensions system .pdfElectronically Controlled suspensions system .pdf
Electronically Controlled suspensions system .pdfme23b1001
 
Instrumentation, measurement and control of bio process parameters ( Temperat...
Instrumentation, measurement and control of bio process parameters ( Temperat...Instrumentation, measurement and control of bio process parameters ( Temperat...
Instrumentation, measurement and control of bio process parameters ( Temperat...121011101441
 
What are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptxWhat are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptxwendy cai
 
Introduction-To-Agricultural-Surveillance-Rover.pptx
Introduction-To-Agricultural-Surveillance-Rover.pptxIntroduction-To-Agricultural-Surveillance-Rover.pptx
Introduction-To-Agricultural-Surveillance-Rover.pptxk795866
 
Past, Present and Future of Generative AI
Past, Present and Future of Generative AIPast, Present and Future of Generative AI
Past, Present and Future of Generative AIabhishek36461
 
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube ExchangerStudy on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube ExchangerAnamika Sarkar
 
TechTAC® CFD Report Summary: A Comparison of Two Types of Tubing Anchor Catchers
TechTAC® CFD Report Summary: A Comparison of Two Types of Tubing Anchor CatchersTechTAC® CFD Report Summary: A Comparison of Two Types of Tubing Anchor Catchers
TechTAC® CFD Report Summary: A Comparison of Two Types of Tubing Anchor Catcherssdickerson1
 

Último (20)

CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdfCCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
 
Heart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptxHeart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptx
 
🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...
🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...
🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...
 
Work Experience-Dalton Park.pptxfvvvvvvv
Work Experience-Dalton Park.pptxfvvvvvvvWork Experience-Dalton Park.pptxfvvvvvvv
Work Experience-Dalton Park.pptxfvvvvvvv
 
An introduction to Semiconductor and its types.pptx
An introduction to Semiconductor and its types.pptxAn introduction to Semiconductor and its types.pptx
An introduction to Semiconductor and its types.pptx
 
Design and analysis of solar grass cutter.pdf
Design and analysis of solar grass cutter.pdfDesign and analysis of solar grass cutter.pdf
Design and analysis of solar grass cutter.pdf
 
Concrete Mix Design - IS 10262-2019 - .pptx
Concrete Mix Design - IS 10262-2019 - .pptxConcrete Mix Design - IS 10262-2019 - .pptx
Concrete Mix Design - IS 10262-2019 - .pptx
 
Call Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call GirlsCall Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call Girls
 
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
 
CCS355 Neural Networks & Deep Learning Unit 1 PDF notes with Question bank .pdf
CCS355 Neural Networks & Deep Learning Unit 1 PDF notes with Question bank .pdfCCS355 Neural Networks & Deep Learning Unit 1 PDF notes with Question bank .pdf
CCS355 Neural Networks & Deep Learning Unit 1 PDF notes with Question bank .pdf
 
Churning of Butter, Factors affecting .
Churning of Butter, Factors affecting  .Churning of Butter, Factors affecting  .
Churning of Butter, Factors affecting .
 
young call girls in Green Park🔝 9953056974 🔝 escort Service
young call girls in Green Park🔝 9953056974 🔝 escort Serviceyoung call girls in Green Park🔝 9953056974 🔝 escort Service
young call girls in Green Park🔝 9953056974 🔝 escort Service
 
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdfCCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
 
Electronically Controlled suspensions system .pdf
Electronically Controlled suspensions system .pdfElectronically Controlled suspensions system .pdf
Electronically Controlled suspensions system .pdf
 
Instrumentation, measurement and control of bio process parameters ( Temperat...
Instrumentation, measurement and control of bio process parameters ( Temperat...Instrumentation, measurement and control of bio process parameters ( Temperat...
Instrumentation, measurement and control of bio process parameters ( Temperat...
 
What are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptxWhat are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptx
 
Introduction-To-Agricultural-Surveillance-Rover.pptx
Introduction-To-Agricultural-Surveillance-Rover.pptxIntroduction-To-Agricultural-Surveillance-Rover.pptx
Introduction-To-Agricultural-Surveillance-Rover.pptx
 
Past, Present and Future of Generative AI
Past, Present and Future of Generative AIPast, Present and Future of Generative AI
Past, Present and Future of Generative AI
 
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube ExchangerStudy on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
 
TechTAC® CFD Report Summary: A Comparison of Two Types of Tubing Anchor Catchers
TechTAC® CFD Report Summary: A Comparison of Two Types of Tubing Anchor CatchersTechTAC® CFD Report Summary: A Comparison of Two Types of Tubing Anchor Catchers
TechTAC® CFD Report Summary: A Comparison of Two Types of Tubing Anchor Catchers
 

Base isolation

  • 1. Technical Seminar Report on BASE ISOLATION CONCEPT AND TECHNIQUES BY M. PREM SAI 11H61A0135 DEPARTMENT OF CIVIL ENGINEERING ANURAG GROUP OF INSTITUTIONS, VENKATAPUR, HYDERABAD
  • 2. CONTENTS  INTRODUCTION  BASE ISOLATION  CONCEPT OF BASE ISOLATION  PRINCIPLE OF BASE ISOLATION  SUITABILITY OF BASE ISOLATION  FIXED BASE STRUCTURE VS ISOLATED BASE STRUCTURE  ISOLATION COMPONENTS  ISOLATOR LOCATIONS  IN REAL SCENARIO  APPLICATIONS  CONCLUSION
  • 3. 1. INTRODUCTION  Earthquake by itself, is not a disaster, it is natural phenomenon result from ground movement, sometimes violent.  These produce surface waves, which cause vibration of the ground and structures standing on top.  Depending on the characteristics of these vibrations, the ground may develop cracks, fissures and settlements.
  • 4.  The possible risk of loss of life adds a very serious dimension to seismic design, putting a moral responsibility on structural engineers.  In recent times, many new systems have been developed, either to reduce the earthquake forces acting on the structure or to absorb a part of seismic energy.  One of the most widely implemented and accepted seismic protection systems is base isolation. 1. INTRODUCTION
  • 5. 2. BASE ISOLATION  Base isolation is one of the most widely accepted seismic protection systems in earthquake prone areas.  It mitigates the effect of an earthquake by essentially isolating the structure from potentially dangerous ground motions.  Seismic isolation is a design strategy, which uncouples the structure for the damaging effects of the ground motion.
  • 6.  The term isolation refers to reduced interaction between structure and the ground.  When the seismic isolation system is located under the structure, it is referred as “base isolation”.  The other purpose of an isolation system is to provide an additional means of energy dissipation, thereby reducing the transmitted acceleration into the superstructure.  The decoupling allows the building to behave more flexibly which improves its response to an earthquake. 2. BASE ISOLATION
  • 7. 3. CONCEPT OF BASE ISOLATION  The concept of base isolation is explained through an example building resting on frictionless rollers.  When the ground shakes, the rollers freely roll, but the building above does not move.  Thus, no force is transferred to the building due to shaking of the ground; simply, the building does not experience the earthquake.
  • 8. 3. CONCEPT OF BASE ISOLATION
  • 9.  Now, if the same building is rested on flexible pads that offer resistance against lateral movements, then some effect of the ground shaking will be transferred to the building above.  The flexible pads are called base-isolators, whereas the structures protected by means of these devices are called base-isolated buildings.  The main feature of the base isolation technology is that it introduces flexibility in the structure. 3. CONCEPT OF BASE ISOLATION
  • 10. 3. CONCEPT OF BASE ISOLATION
  • 11.  A careful study is required to identify the most suitable type of device for a particular building.  Also, base isolation is not suitable for all buildings.  Most suitable structures for base-isolation are  Low to medium-rise buildings rested on hard soil underneath  High-rise buildings or buildings rested on soft soil are not suitable for base isolation. 3. CONCEPT OF BASE ISOLATION
  • 12. 4. PRINCIPLE OF BASE ISOLATION  The fundamental principle of base isolation is to modify the response of the building so that the ground can move below the building without transmitting these motions into the building.  A building that is perfectly rigid will have a zero period.  When the ground moves the acceleration induced in the structure will be equal to the ground acceleration and there will be zero relative displacement between the structure and the ground.
  • 13.  The structure and ground move the same amount.  A building that is perfectly flexible will have an infinite period.  For this type of structure, when the ground beneath the structure moves there will be zero acceleration induced in the structure and the relative displacement between the structure and ground will be equal to the ground displacement. 4. PRINCIPLE OF BASE ISOLATION
  • 14.  So in flexible structures the structure will not move, the ground will. 4. PRINCIPLE OF BASE ISOLATION
  • 15. 5. SUITABILITY OF BASE ISOLATION  Earthquake protection of structures using base isolation technique is generally suitable if the following conditions are fulfilled  The subsoil does not produce a predominance of long period ground motion.  The structure is fairly jointed with sufficiently high column load.  The site permits horizontal displacements at the base of the order of 200 mm or more.  Lateral loads due to wind are less than approximately 10% of the weight of the structure.
  • 16. 6. Fixed Base Structure vs Isolated Base Structure  During earthquakes, the conventional structure without seismic isolation is subjected to substantial story drifts, which may lead to damage or even collapse of the building.  Whereas the isolated structure vibrates almost like a rigid body with large deformations or displacements restricted by the isolation bearings.  The decoupling effect gives this extra advantange to isolated structures.
  • 17.  The lateral forces of the isolated building are not only reduced in magnitude but also fairly redistributed over the floors, which further mitigates the overturning moment of the structure. 6. Fixed Base Structure vs Isolated Base Structure
  • 18. 6. Fixed Base Structure vs Isolated Base Structure
  • 19. 7. ISOLATION COMPONENTS  Elastomeric Isolators  Natural Rubber Bearings  Low-Damping Rubber Bearings  Lead-Rubber Bearings  High-Damping Rubber Bearings  Sliding Isolators  Resilient Friction System  Friction Pendulum System
  • 20.  Elastomeric Isolators  These are formed of horizontal layers of natural or synthetic rubber in thin layers bonded between steel plates.  The steel plates prevent the rubber layers from bulging and so the bearing is able to support higher vertical loads with only small deformations.  Plain elastomeric bearings provide flexibility but no significant damping and will move under service loads. 7. ISOLATION COMPONENTS
  • 21.  Methods used to overcome these deficits include lead cores in the bearing, specially formulated elastomers with high damping and stiffness for small strains or other devices in parallel. 7. ISOLATION COMPONENTS
  • 22.  Low Damping Natural or Synthetic Rubber Bearings  Elastomeric bearings use either natural rubber or synthetic rubber (such as neoprene), which have little inherent damping, usually 2% to 3% of critical viscous damping.  For isolation they are generally used with special elastomer compounds (high damping rubber bearings) or in combination with other devices (lead rubber bearings).  They are also flexible at all strain levels. 7. ISOLATION COMPONENTS
  • 23.  Lead Rubber Bearings  A lead-rubber bearing is formed of a lead plug force-fitted into a pre-formed hole in an elastomeric bearing.  The lead core provides rigidity under service loads and energy dissipation under high lateral loads.  Top and bottom steel plates, thicker than the internal shims, are used to accommodate mounting hardware. The entire bearing is encased in cover rubber to provide environmental protection. 7. ISOLATION COMPONENTS
  • 24.  When subjected to low lateral loads (such as minor earthquake, wind or traffic loads) the lead rubber bearing is stiff both laterally and vertically.  The lateral stiffness results from the high elastic stiffness of the lead plug and the vertical rigidity (which remains at all load levels) results from the steel-rubber construction of the bearing. 7. ISOLATION COMPONENTS
  • 25.  Isolation Systems based on Sliding  The second most common type of isolation system uses sliding elements between the foundation and base of the structure.  In this type of Isolation system, the sliding displacements are controlled by high-tension springs or laminated rubber bearings, or by making the sliding surface curved.  These mechanisms provide a restoring force to return the structure to its equilibrium position. 7. ISOLATION COMPONENTS
  • 26.  Sliding isolator without Recentering capacity  This consists of a horizontal sliding surface, allowing a displacement and thus dissipating energy by means of defined friction between both sliding components and stainless steel.  One particular problem with a sliding structure is the residual displacements that occur after major earthquakes. 7. ISOLATION COMPONENTS
  • 27.  Sliding Isolator with Recentering Capacity  Compared with sliding isolators, sliding isolation pendula (SIPs) with recentering capacity have a concave sliding plate.  Due to geometry, each horizontal displacement results in a vertical movement of the isolator.  The potential energy, stored by the superstructure, which has been pushed to the top, automatically results in recentering the bearing into neutral position. 7. ISOLATION COMPONENTS
  • 28.  They remain horizontally flexible, dissipate energy and recenter the superstructure into neutral position. 7. ISOLATION COMPONENTS
  • 29.  Friction Pendulum System  The Friction pendulum system (FPS) is a sliding isolation system wherein the weight of the structure is supported on spherical sliding surfaces that slide relative to each other when the ground motion exceeds a threshold level. 7. ISOLATION COMPONENTS
  • 30. 8. Isolator Locations  The requirement for installation of a base isolation system is that the building be able to move horizontally relative to the ground, usually at least 100 mm.  The most common configuration is to install a diaphragm immediately above the isolators.  If the building has a basement then the options are to install the isolators at the top, bottom or mid-height of the basements columns and walls.
  • 32. 9. BASE ISOLATION IN REAL BUILDINGS  Seismic isolation is a relatively recent and evolving technology. It has been in increased use since the 1980s, and has been well evaluated and reviewed internationally.  Base isolation is also useful for retrofitting important buildings (like hospitals and historic buildings).  By now, over 1000 buildings across the world have been equipped with seismic base isolation.
  • 33.  In India, base isolation technique was first demonstrated after the 1993 Killari (Maharashtra) Earthquake.  Two single storey buildings in newly relocated Killari town were built with rubber base isolators resting on hard ground.  After the 2001 Bhuj (Gujarat) earthquake, the four-storey Bhuj Hospital building was built with base isolation technique.  All were brick masonry buildings with concrete roof. 9. BASE ISOLATION IN REAL BUILDINGS
  • 34.  The figure shows the base isolation technique used in the Bhuj Hospital building with the help of Base Isolators. 9. BASE ISOLATION IN REAL BUILDINGS
  • 35. 10. APPLICATIONS  Base isolation provides an alternative to the conventional, fixed base design of structures.  Base Isolation minimizes the need for strengthening measures of adding shear walls, frames, and bracing by reducing the earthquake forces imparted to the building.  Base isolation had the effect of reducing the earthquake force demands on the superstructure to 30% of the demands for a fixed-base structure.
  • 36. 11. CONCLUSION  Seismic base isolation method has proved to be a reliable method of earthquake resistant Design.  The success of this method is largely attributed to the development of isolation devices and proper planning.  Adaptable isolation systems are required to be effective during a wide range of seismic events.  Efforts are required to find the solutions for the situations like near fault regions where wide variety of earthquake motions may occur.