SIEMENS SIMATIC WINCC 7.X


SCADA SECURITY HARDENING GUIDE
          PUBLIC BETA

          27 DEC 2012
CONTENTS


LEGAL NOTES........................................................................................................................................................ 4
1. OPERATING SYSTEM CONFIGURATION .............................................................................................. 5
1.1 Use compatible Windows version .......................................................................................................... 5
1.2 Ensure appropriate Windows language settings.............................................................................. 5
1.3 Ensure the latest Windows updates are installed ........................................................................... 5
1.4 Enable unsigned drivers installation..................................................................................................... 5
1.5 Set user interface restrictions ................................................................................................................ 5
1.6 Set system parameters according to the vendor's requirements ............................................. 6
1.7 Ensure control of system group membership restrictions ........................................................... 6
2. SYSTEM NETWORK PARAMETERS CONFIGURATION ..................................................................... 7
2.1 Disable access to external networks .................................................................................................... 7
2.2 Do not install Novell Netware clients ................................................................................................... 7
3. DBMS CONFIGURATION ............................................................................................................................ 7
3.1 Ensure installation of the latest security updates for Microsoft SQL 2005 ........................... 7
3.2 Use strong system administrator password ...................................................................................... 7
3.3 Provide SIMATIC HMI users with SQL access rights ...................................................................... 7
4. ADDITIONAL SECURITY TOOLS ............................................................................................................. 8
4.1 Install compatible antivirus software ................................................................................................... 8
4.2 Use up-to-date antivirus software ........................................................................................................ 8
5. SIMATIC WINCC (SYSTEM PARAMETERS) ........................................................................................ 8
5.1 Do not use the WinCC DiagAgent (CCDiagAgent) application in production systems ...... 8
5.2 Ensure WinCC Runtime launch as a system service ...................................................................... 8
5.3 Disable WinCC Runtime autostart cancelling .................................................................................... 8
6. SIMATIC WINCC (SIMATIC LOGON CONFIGURATIONS) ............................................................ 9
6.1 Set logon time-out ...................................................................................................................................... 9
6.2 Enable password change reminder ....................................................................................................... 9
7. SIMATIC WINCC (ACCESS CONFIGURATIONS) ...........................................................................10
7.1 Change default passwords for demonstration accounts .............................................................10
7.2 Change administrator’s default password ........................................................................................10
7.3 Control password strength for HMI access accounts ...................................................................10
7.4 Restrict management group membership........................................................................................10
7.5 Disable access via local groups ............................................................................................................11
8. SIMATIC WINCC (EVENTS LOGGING) ..............................................................................................11
8.1 Enable logon events logging to archive ............................................................................................11
8.2 Enable logon events logging to the Windows system log ..........................................................11
9. SIMATIC WINCC (PROJECT CONTROL) ............................................................................................11
9.1 Disable interface management hotkeys ...........................................................................................11
10. SIMATIC WINCC (WEBNAVIGATOR — SCREEN PUBLISHING) ...............................................12
10.1           Publish only necessary screens ...............................................................................................12




         SIEMENS WINCC 7.X /SECURITY HARDENING GUIDE                                                                          Page 3 of 12
LEGAL NOTES

   The copyright on the materials contained in this documentation belong to the Closed Joint Stock
   Company “Positive Technologies” and is protected in accordance with the applicable rules of national
   law of the Russian Federation and of International law exclusive of any choice of any other local law
   rules. The quoting and use of these materials are allowed only in compliance with the legislation
   stipulated above and with obligatory indication of the copyright holder and of the source of borrowing.

   The Closed Joint Stock Company “Positive Technologies” shall not be responsible for the consequences
   resulting from the use of these materials or inability of such use. The Closed Joint Stock Company
   “Positive Technologies” holds no responsibility for any decisions made by users on the basis of these
   materials and for any results obtained according to such decisions.




   SIEMENS WINCC 7.X /SECURITY HARDENING GUIDE                                                Page 4 of 12
1.    OPERATING SYSTEM CONFIGURATION

1.1   Use compatible Windows version

      Install WinCC on those operating systems that are supported by the vendor.
      Recommendations:
      To     verify   whether     the    Windows    version   is   compatible, use    the   list
      http://cache.automation.siemens.com/dnl/zQ/zQzMjEzAAAA_21927773_FAQ/WinCC_V70_compatibilit
      y_list_e.pdf.

1.2   Ensure appropriate Windows language settings

      WinCC is available only for operating systems with the following language interfaces:
             German
             English
             French
             Italian
             Spanish
             Multilingual User Interface (MUI)*
      *For MUI systems, the OS language should be English.
      Recommendations:
      To make sure the OS language settings are appropriate, verify the language used in the system: Start ->
      Control Panel -> Regional and Language Options.

1.3   Ensure the latest Windows updates are installed

      For supporting Windows up-to-date security level, it is required to check for updates regularly.

      Recommendations:
      Ensure that all the latest OS updates have been installed.

1.4   Enable unsigned drivers installation

      For WinCC proper functioning on a Windows operating system, it is necessary to disable the default
      check for drivers’ signatures on installation.

      Recommendations:
      Verify that the installation of unsigned drivers is allowed.

1.5   Set user interface restrictions

      It is necessary to restrict user actions performed via Windows interface in the WinCC environment. It is
      required to disable such hotkeys as Ctr+Alt+Del, Alt+Esc, Alt+Tab, Ctl+Esc.

      Recommendations:




      SIEMENS WINCC 7.X /SECURITY HARDENING GUIDE                                                  Page 5 of 12
To verify the status of restriction on WinCC user interface, go to WinCC Explorer -> Computer properties
      -> Parameters -> Disable Keys.

      Verify the following registry key values:

      For 64-bit Windows systems:

      [HKEY_LOCAL_MACHINESOFTWAREWow6432NodeSiemensWinCCWinlogonPermissions]
      "AllowShutdown"=dword:00000001
      "AllowLogout"=dword:00000001
      "AllowCtlAltDel"=dword:00000001
      "AllowAltEsc"=dword:00000000
      "AllowAltTab"=dword:00000001
      "AllowCtlEsc"=dword:00000000

      For 64-bit Windows systems:

      [HKEY_LOCAL_MACHINESOFTWARE SiemensWinCCWinlogonPermissions]
      "AllowShutdown"=dword:00000001
      "AllowLogout"=dword:00000001
      "AllowCtlAltDel"=dword:00000001
      "AllowAltEsc"=dword:00000000
      "AllowAltTab"=dword:00000001
      "AllowCtlEsc"=dword:00000000

1.6   Set system parameters according to the vendor's requirements

      For WinCC proper functioning on a Windows operating system, it is necessary to configure the operating
      system according to the vendor's requirements. Configure following parameters:
          - User group
          - Registry settings and rights
          - Firewall settings
          - DCOM settings
          - File system rights

      Recommendations:
      Ensure that the system parameters are set according to the vendor's requirements. You can use
      SIMATIC Security Control (SecurityController.exe) tool to automate configuration process.

1.7   Ensure control of system group membership restrictions

      It is required to ensure control over the membership restrictions of such system groups as
      Administrator, Server Operators, and Power Users.

      Recommendations:
      Ensure that membership restrictions set for the specified system groups are correct.




      SIEMENS WINCC 7.X /SECURITY HARDENING GUIDE                                               Page 6 of 12
2.    SYSTEM NETWORK PARAMETERS CONFIGURATION

2.1   Disable access to external networks

      For maximum security, it is necessary to divide networks by the following categories: networks for
      management, for data transmission, and main purpose networks. So, if an attacker penetrates into one
      of the networks, system compromise may be avoided.

      Recommendations:
      To verify external networks availability, use the netstat application with the -rn parameters.

2.2   Do not install Novell Netware clients

      Avoid installing WinCC on the system together with the Novell client's software.
      Such an installation may result in failure to log into the Novell system or to lock the keyboard in the
      execution environment.

      Recommendations:
      Ensure that the Netware client's software or Microsoft client for Netware are not used.


3.    DBMS CONFIGURATION

3.1   Ensure installation of the latest security updates for Microsoft SQL 2005

      For supporting up-to-date security level of SQL Server, it is required to check for updates regularly.

      Recommendations:
      Ensure that all the latest SQL Server updates have been installed.

3.2   Use strong system administrator password

      Only the ASCII characters can be used for the password of the SQL Server system administrator. The
      password should contain at least 14 characters.

      Recommendations:
      Ensure that a strong password is used for the system administrator account.

3.3   Provide SIMATIC HMI users with SQL access rights


      To receive access to WinCC in Microsoft SQL Server 2005, the SIMATIC HMI group members should have
      appropriate rights. For provision of the access rights, it is required to add users to the group
      SQLServer2005MSSQLUser$<COMPUTERNAME>$WINCC.

      Recommendations:
      Verify that SIMATIC HMI users have been provided with SQL Server access rights.




      SIEMENS WINCC 7.X /SECURITY HARDENING GUIDE                                                   Page 7 of 12
4.    ADDITIONAL SECURITY TOOLS

4.1   Install compatible antivirus software

      It is recommended to install only that antivirus software which is compatible with the WinCC software
      installed on your operating system.

      Recommendations:
      To ensure that the installed antivirus software is compatible, use the list
      http://cache.automation.siemens.com/dnl/zQ/zQzMjEzAAAA_21927773_FAQ/WinCC_V70_compatibilit
      y_list_e.pdf.

4.2   Use up-to-date antivirus software

      The antivirus software should be active and should use an up-to-date database.

      Recommendations:
      Verify that antivirus software is active. To ensure that the antivirus software database is up-to-date, use
      recommendations of antivirus software vendor.


5.    SIMATIC WINCC (SYSTEM PARAMETERS)

5.1   Do not use the WinCC DiagAgent (CCDiagAgent) application in production systems

      WinCC DiagAgent (CCDiagAgent) is used to control and diagnose Simatic WinCC, operating system, and
      DBMS. By default, the application does not require authorization, which may allow a remote attacker to
      alter system configuration and execute arbitrary code. Ensure that this application has been removed or
      is not running on production systems.

      Recommendations:
      To ensure the application is not used in production systems, it is required to regularly check that there is
      no CCDiagAgent.exe among the processes running on the operating system. Use SIMATIC Diagnostics Tool
      or         the         SIMATIC           Analyser.                   http://www.siemens.com/corporate-
      technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-223158.pdf

5.2   Ensure WinCC Runtime launch as a system service

      It is required to ensure that WinCC Runtime is launched as a system service.

      Recommendations:
      To ensure that WinCC Runtime is launched as a system service, verify service settings available here:
      Project properties -> Operation mode -> Service.

5.3   Disable WinCC Runtime autostart cancelling

      If autostart is configured for the WinCC project, it is required to ensure that the Allow "Cancel" during
      activation option of the AutoStart Configuration application is disabled.

      Recommendations:


      SIEMENS WINCC 7.X /SECURITY HARDENING GUIDE                                                   Page 8 of 12
To ensure the specified option is disabled, verify which settings are enabled by launching the AutoStart
      Configuration application available here: Program FilesSiemensWinCCbinAutoStartRT.exe.

      Additionally, verify the EnableBreak value in the Windows registry.

      [HKEY_LOCAL_MACHINESOFTWAREWow6432NodeSiemensWinCCAutoStartWinCC]
      "ProjectName"="C:UsersPublicDocumentsSiemensWinCCProjects123123.MCP"
      "Activate"=dword:00000000 (Activate project at startup)
      "EnableBreak"=dword:00000001.
      "AllUsers"=dword:00000000 (available for all users)
      "NCGM"=dword:00000000
      "RedProject"=dword:00000000
      "RedProjectName"=""
      "StartInServiceMode"=dword:00000000


6.    SIMATIC WINCC (SIMATIC LOGON CONFIGURATIONS)

6.1   Set logon time-out

      If the SIMATIC LOGON application is used, it is necessary to activate the automatic logoff function and
      set a logon time-out.

      Recommendations:
      To ensure the logon time-out is set, verify the SIMATIC LOGON settings using the following configuration
      file: C:Documents and Settings{All UsersDocuments} SiemensSIMATICLogonsettingsslsettings.ini.

      Configuration file control parameters:
      [Screensaver]
      UseScreensaver=1 — Used SIMATIC Logon automatic logoff
      WaitTime=46620 — Delay Time in Seconds
      TimeToLogout=30 — Time until automatic logoff

6.2   Enable password change reminder

      If the SIMATIC LOGON application is used, it is necessary to activate the function of the password
      change reminder. The relevant option should be configured in such a way so that the reminder appears
      not earlier than two months prior to the password change.

      Recommendations:
      To ensure the password change reminder is enabled, verify the SIMATIC LOGON parameters using the
      following configuration file: C:Documents and Settings{All UsersDocuments}
      SiemensSIMATICLogonsettingsslsettings.ini.

      Configuration file control parameters:
      [Config]
      Reminder=0 — Days for reminder of password expiration




      SIEMENS WINCC 7.X /SECURITY HARDENING GUIDE                                               Page 9 of 12
7.    SIMATIC WINCC (ACCESS CONFIGURATIONS)

7.1   Change default passwords for demonstration accounts

      It is required to change the following default passwords for the WinCC demo accounts:
             winccd/winccpass
             wincce/winccpass
             DMUser/Data&Pass

      Recommendations:
      Ensure the default passwords for the demo accounts have been changed. It’s recommended to delete
      this accounts in production environment

      Links:
      http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=45027800&c
      aller=view

7.2   Change administrator’s default password

      It is required to change the following WinCC administrator password created by default:
      Administrator/Administrator.

      Recommendations:
      To ensure the default password is not used for the administrator account, verify the WinCC user list via
      the following database query:

      SELECT * FROM {database_name}.dbo.PW_USER

      Use automatic tools to control password complexity.

7.3   Control password strength for HMI access accounts

      It is necessary to control password strength for group members possessing the rights to change such
      system parameters as:
             User administration
             Value input
             Process controlling

      Recommendations:
      To verify WinCC user rights, use the following database query:

      SELECT * FROM {database_name}.dbo.PW_USER

      Use automatic tools to control password complexity.

7.4   Restrict management group membership

      Control membership in the groups possessing the rights to change such system parameters as:
             User administration

      SIEMENS WINCC 7.X /SECURITY HARDENING GUIDE                                              Page 10 of 12
   Value input
             Process controlling

      Recommendations:
      To verify WinCC user rights, use User Administrator (PassCS.exe) tool.

7.5   Disable access via local groups

      A server with installed WebNavigator should be available only for groups of the same domain.

      Recommendations:
      To ensure that access via local groups is disabled, verify the following option configuration: WinCC Web
      Settings -> Session Logon/Logoff -> Disable local groups of SIMATIC Logon.



8.    SIMATIC WINCC (EVENTS LOGGING)

8.1   Enable logon events logging to archive

      WebNavigator Client logon and logoff successful attempts should be logged (logging of the system
      messages No. 1012400 or 1012401).

      Recommendations:
      To ensure that the event logging is enabled, verify the following option configuration: WinCC Web
      Settings -> Session Logon/Logoff -> Enable WinCC system messages.



8.2   Enable logon events logging to the Windows system log

      It is required to log successful logon sessions to the Windows system log.

      Recommendations:
      To ensure that the event logging is enabled, verify the following option configuration: WinCC Web
      Settings -> Session Logon/Logoff -> Enable event log messages.


9.    SIMATIC WINCC (PROJECT CONTROL)

9.1   Disable interface management hotkeys

      Interface management shortcut keys should be disabled for each project.
      Hotkeys (Alt+F4, Resize, Move, Minimize, Maximize, etc.) for windows management should be disabled
      in the WinCC project settings.

      Recommendations:
      To verify the status of WinCC user interface restrictions, go to WinCC Explorer -> Computer properties ->
      Graphics Runtime.




      SIEMENS WINCC 7.X /SECURITY HARDENING GUIDE                                               Page 11 of 12
10. SIMATIC WINCC (WEBNAVIGATOR — SCREEN PUBLISHING)

10.1 Publish only necessary screens

    It is required to control project screens published via WebNavigator.

    Recommendations:
    To verify only necessary screens are published, go to WinCCExplorer -> WebNavigator -> WinCC Web
    Publishing Wizard -> Select pictures.




    SIEMENS WINCC 7.X /SECURITY HARDENING GUIDE                                           Page 12 of 12

Más contenido relacionado

La actualidad más candente

Manual x58 20 super computer
Manual x58 20 super computerManual x58 20 super computer
Manual x58 20 super computerliourte
 
User Guide - Comodo Free Proactive Protection Software
User Guide - Comodo Free Proactive Protection Software User Guide - Comodo Free Proactive Protection Software
User Guide - Comodo Free Proactive Protection Software websecurity
 
Book VMWARE VMware ESXServer Advanced Technical Design Guide
Book VMWARE VMware ESXServer  Advanced Technical Design Guide Book VMWARE VMware ESXServer  Advanced Technical Design Guide
Book VMWARE VMware ESXServer Advanced Technical Design Guide aktivfinger
 
Dell Inspiron 7537 Card rời 2GB hỗ trợ đồ họa
Dell Inspiron 7537 Card rời 2GB hỗ trợ đồ họaDell Inspiron 7537 Card rời 2GB hỗ trợ đồ họa
Dell Inspiron 7537 Card rời 2GB hỗ trợ đồ họaLAPTOP TRẦN PHÁT
 
G41 m vs2
G41 m vs2G41 m vs2
G41 m vs2ruisuv
 
TechBook: IMS on z/OS Using EMC Symmetrix Storage Systems
TechBook: IMS on z/OS Using EMC Symmetrix Storage SystemsTechBook: IMS on z/OS Using EMC Symmetrix Storage Systems
TechBook: IMS on z/OS Using EMC Symmetrix Storage SystemsEMC
 
Netbackup intallation guide
Netbackup intallation guideNetbackup intallation guide
Netbackup intallation guiderajan981
 
My booklive manual
My booklive manualMy booklive manual
My booklive manualbb129207
 
Www.dedoimedo.com crash-book
Www.dedoimedo.com crash-bookWww.dedoimedo.com crash-book
Www.dedoimedo.com crash-bookSusant Sahani
 

La actualidad más candente (16)

Manual x58 20 super computer
Manual x58 20 super computerManual x58 20 super computer
Manual x58 20 super computer
 
User Guide - Comodo Free Proactive Protection Software
User Guide - Comodo Free Proactive Protection Software User Guide - Comodo Free Proactive Protection Software
User Guide - Comodo Free Proactive Protection Software
 
H61 m vs
H61 m vsH61 m vs
H61 m vs
 
H61 m dgs
H61 m dgsH61 m dgs
H61 m dgs
 
Book VMWARE VMware ESXServer Advanced Technical Design Guide
Book VMWARE VMware ESXServer  Advanced Technical Design Guide Book VMWARE VMware ESXServer  Advanced Technical Design Guide
Book VMWARE VMware ESXServer Advanced Technical Design Guide
 
Dell Inspiron 7537 Card rời 2GB hỗ trợ đồ họa
Dell Inspiron 7537 Card rời 2GB hỗ trợ đồ họaDell Inspiron 7537 Card rời 2GB hỗ trợ đồ họa
Dell Inspiron 7537 Card rời 2GB hỗ trợ đồ họa
 
960 gc gs fx
960 gc gs fx960 gc gs fx
960 gc gs fx
 
G41 m vs2
G41 m vs2G41 m vs2
G41 m vs2
 
TechBook: IMS on z/OS Using EMC Symmetrix Storage Systems
TechBook: IMS on z/OS Using EMC Symmetrix Storage SystemsTechBook: IMS on z/OS Using EMC Symmetrix Storage Systems
TechBook: IMS on z/OS Using EMC Symmetrix Storage Systems
 
Netbackup intallation guide
Netbackup intallation guideNetbackup intallation guide
Netbackup intallation guide
 
Nvr manual
Nvr manualNvr manual
Nvr manual
 
Manual fet-pro430
Manual fet-pro430Manual fet-pro430
Manual fet-pro430
 
My booklive manual
My booklive manualMy booklive manual
My booklive manual
 
H61 m vs r2.0
H61 m vs r2.0H61 m vs r2.0
H61 m vs r2.0
 
Www.dedoimedo.com crash-book
Www.dedoimedo.com crash-bookWww.dedoimedo.com crash-book
Www.dedoimedo.com crash-book
 
H61 m vg3p;
H61 m vg3p;H61 m vg3p;
H61 m vg3p;
 

Similar a Positive Technologies WinCC Security Hardening Guide

Monitoring Windows Server Systems Demo Script
Monitoring Windows Server Systems Demo ScriptMonitoring Windows Server Systems Demo Script
Monitoring Windows Server Systems Demo ScriptMicrosoft TechNet
 
CCTV Nu client user_manual
CCTV Nu client user_manualCCTV Nu client user_manual
CCTV Nu client user_manualMAFANTIRI SELLO
 
Siemens catalog hmi-tp070_e
Siemens catalog hmi-tp070_eSiemens catalog hmi-tp070_e
Siemens catalog hmi-tp070_eDien Ha The
 
Siemens catalog hmi-tp070 touch panel
Siemens catalog hmi-tp070 touch panelSiemens catalog hmi-tp070 touch panel
Siemens catalog hmi-tp070 touch panelDien Ha The
 
System Client Details
System Client DetailsSystem Client Details
System Client DetailsSyAM Software
 
Faronics Insight Tech Console User guide
Faronics Insight Tech Console User guideFaronics Insight Tech Console User guide
Faronics Insight Tech Console User guideFaronics
 
Xen app getting-started-guide
Xen app getting-started-guideXen app getting-started-guide
Xen app getting-started-guidehergamia
 
Safeconsole admin guide
Safeconsole admin guideSafeconsole admin guide
Safeconsole admin guideMariusEnescu3
 
Ovms ops manager_admin
Ovms ops manager_adminOvms ops manager_admin
Ovms ops manager_adminsati1981
 
Lenze manual global drive gdc en
Lenze manual global drive gdc enLenze manual global drive gdc en
Lenze manual global drive gdc enCharles Santos
 
Vista deployment using tivoli provisioning manager for os deployment redp4295
Vista deployment using tivoli provisioning manager for os deployment redp4295Vista deployment using tivoli provisioning manager for os deployment redp4295
Vista deployment using tivoli provisioning manager for os deployment redp4295Banking at Ho Chi Minh city
 

Similar a Positive Technologies WinCC Security Hardening Guide (20)

Monitoring Windows Server Systems Demo Script
Monitoring Windows Server Systems Demo ScriptMonitoring Windows Server Systems Demo Script
Monitoring Windows Server Systems Demo Script
 
AltiGen Alti Console Manual
AltiGen Alti Console ManualAltiGen Alti Console Manual
AltiGen Alti Console Manual
 
Cms instruction 1.0
Cms instruction 1.0Cms instruction 1.0
Cms instruction 1.0
 
CCTV Nu client user_manual
CCTV Nu client user_manualCCTV Nu client user_manual
CCTV Nu client user_manual
 
Readme
ReadmeReadme
Readme
 
Siemens catalog hmi-tp070_e
Siemens catalog hmi-tp070_eSiemens catalog hmi-tp070_e
Siemens catalog hmi-tp070_e
 
Siemens catalog hmi-tp070 touch panel
Siemens catalog hmi-tp070 touch panelSiemens catalog hmi-tp070 touch panel
Siemens catalog hmi-tp070 touch panel
 
AltiGen Max In Sight Manual
AltiGen Max In Sight  ManualAltiGen Max In Sight  Manual
AltiGen Max In Sight Manual
 
System Client Details
System Client DetailsSystem Client Details
System Client Details
 
Svcrsp 1.3p1
Svcrsp 1.3p1Svcrsp 1.3p1
Svcrsp 1.3p1
 
Faronics Insight Tech Console User guide
Faronics Insight Tech Console User guideFaronics Insight Tech Console User guide
Faronics Insight Tech Console User guide
 
SysInfoTools MS Excel XLSX Repair
SysInfoTools MS Excel XLSX RepairSysInfoTools MS Excel XLSX Repair
SysInfoTools MS Excel XLSX Repair
 
Xen app getting-started-guide
Xen app getting-started-guideXen app getting-started-guide
Xen app getting-started-guide
 
Safeconsole admin guide
Safeconsole admin guideSafeconsole admin guide
Safeconsole admin guide
 
Ovms ops manager_admin
Ovms ops manager_adminOvms ops manager_admin
Ovms ops manager_admin
 
Cms3.0 user manual
Cms3.0 user manualCms3.0 user manual
Cms3.0 user manual
 
Lenze manual global drive gdc en
Lenze manual global drive gdc enLenze manual global drive gdc en
Lenze manual global drive gdc en
 
Oc130 v4hp3000ug
Oc130 v4hp3000ugOc130 v4hp3000ug
Oc130 v4hp3000ug
 
Remote Management
Remote ManagementRemote Management
Remote Management
 
Vista deployment using tivoli provisioning manager for os deployment redp4295
Vista deployment using tivoli provisioning manager for os deployment redp4295Vista deployment using tivoli provisioning manager for os deployment redp4295
Vista deployment using tivoli provisioning manager for os deployment redp4295
 

Más de qqlan

D1 t1 t. yunusov k. nesterov - bootkit via sms
D1 t1   t. yunusov k. nesterov - bootkit via smsD1 t1   t. yunusov k. nesterov - bootkit via sms
D1 t1 t. yunusov k. nesterov - bootkit via smsqqlan
 
Kaspersky SAS SCADA in the Cloud
Kaspersky SAS SCADA in the CloudKaspersky SAS SCADA in the Cloud
Kaspersky SAS SCADA in the Cloudqqlan
 
Миссиоцентрический подход к кибербезопасности АСУ ТП
Миссиоцентрический подход к кибербезопасности АСУ ТПМиссиоцентрический подход к кибербезопасности АСУ ТП
Миссиоцентрический подход к кибербезопасности АСУ ТПqqlan
 
ABUSE THEIR CLOUDS. ОБЛАЧНЫЕ ВЫЧИСЛЕНИЯ ГЛАЗАМИ ПЕНТЕСТЕРА, ЮРИЙ ГОЛЬЦЕВ, СЕ...
ABUSE THEIR CLOUDS. ОБЛАЧНЫЕ ВЫЧИСЛЕНИЯ ГЛАЗАМИ ПЕНТЕСТЕРА, ЮРИЙ ГОЛЬЦЕВ, СЕ...ABUSE THEIR CLOUDS. ОБЛАЧНЫЕ ВЫЧИСЛЕНИЯ ГЛАЗАМИ ПЕНТЕСТЕРА, ЮРИЙ ГОЛЬЦЕВ, СЕ...
ABUSE THEIR CLOUDS. ОБЛАЧНЫЕ ВЫЧИСЛЕНИЯ ГЛАЗАМИ ПЕНТЕСТЕРА, ЮРИЙ ГОЛЬЦЕВ, СЕ...qqlan
 
Best of Positive Research 2013
Best of Positive Research 2013Best of Positive Research 2013
Best of Positive Research 2013qqlan
 
Web-style Wireless IDS attacks, Sergey Gordeychik
Web-style Wireless IDS attacks, Sergey GordeychikWeb-style Wireless IDS attacks, Sergey Gordeychik
Web-style Wireless IDS attacks, Sergey Gordeychikqqlan
 
G. Gritsai, A. Timorin, Y. Goltsev, R. Ilin, S. Gordeychik, and A. Karpin, “S...
G. Gritsai, A. Timorin, Y. Goltsev, R. Ilin, S. Gordeychik, and A. Karpin, “S...G. Gritsai, A. Timorin, Y. Goltsev, R. Ilin, S. Gordeychik, and A. Karpin, “S...
G. Gritsai, A. Timorin, Y. Goltsev, R. Ilin, S. Gordeychik, and A. Karpin, “S...qqlan
 
SCADA StrangeLove: Too Smart Grid in da Cloud [31c3]
SCADA StrangeLove: Too Smart Grid in da Cloud [31c3]SCADA StrangeLove: Too Smart Grid in da Cloud [31c3]
SCADA StrangeLove: Too Smart Grid in da Cloud [31c3]qqlan
 
Pt infosec - 2014 - импортозамещение
Pt   infosec - 2014 - импортозамещениеPt   infosec - 2014 - импортозамещение
Pt infosec - 2014 - импортозамещениеqqlan
 
SCADA StrangeLove Kaspersky SAS 2014 - LHC
SCADA StrangeLove Kaspersky SAS 2014 - LHCSCADA StrangeLove Kaspersky SAS 2014 - LHC
SCADA StrangeLove Kaspersky SAS 2014 - LHCqqlan
 
Firebird Interbase Database engine hacks or rtfm
Firebird Interbase Database engine hacks or rtfmFirebird Interbase Database engine hacks or rtfm
Firebird Interbase Database engine hacks or rtfmqqlan
 
SCADA StrangeLove 2: We already know
SCADA StrangeLove 2:  We already knowSCADA StrangeLove 2:  We already know
SCADA StrangeLove 2: We already knowqqlan
 
Internet connected ICS/SCADA/PLC
Internet connected ICS/SCADA/PLCInternet connected ICS/SCADA/PLC
Internet connected ICS/SCADA/PLCqqlan
 
SCADA deep inside:protocols and software architecture
SCADA deep inside:protocols and software architectureSCADA deep inside:protocols and software architecture
SCADA deep inside:protocols and software architectureqqlan
 
Techniques of attacking ICS systems
Techniques of attacking ICS systems Techniques of attacking ICS systems
Techniques of attacking ICS systems qqlan
 
Positive Technologies Application Inspector
Positive Technologies Application InspectorPositive Technologies Application Inspector
Positive Technologies Application Inspectorqqlan
 
Database honeypot by design
Database honeypot by designDatabase honeypot by design
Database honeypot by designqqlan
 
Positive Technologies Application Inspector
Positive Technologies Application InspectorPositive Technologies Application Inspector
Positive Technologies Application Inspectorqqlan
 
Black Hat: XML Out-Of-Band Data Retrieval
Black Hat: XML Out-Of-Band Data RetrievalBlack Hat: XML Out-Of-Band Data Retrieval
Black Hat: XML Out-Of-Band Data Retrievalqqlan
 
ICS/SCADA/PLC Google/Shodanhq Cheat Sheet v2
ICS/SCADA/PLC Google/Shodanhq Cheat Sheet v2ICS/SCADA/PLC Google/Shodanhq Cheat Sheet v2
ICS/SCADA/PLC Google/Shodanhq Cheat Sheet v2qqlan
 

Más de qqlan (20)

D1 t1 t. yunusov k. nesterov - bootkit via sms
D1 t1   t. yunusov k. nesterov - bootkit via smsD1 t1   t. yunusov k. nesterov - bootkit via sms
D1 t1 t. yunusov k. nesterov - bootkit via sms
 
Kaspersky SAS SCADA in the Cloud
Kaspersky SAS SCADA in the CloudKaspersky SAS SCADA in the Cloud
Kaspersky SAS SCADA in the Cloud
 
Миссиоцентрический подход к кибербезопасности АСУ ТП
Миссиоцентрический подход к кибербезопасности АСУ ТПМиссиоцентрический подход к кибербезопасности АСУ ТП
Миссиоцентрический подход к кибербезопасности АСУ ТП
 
ABUSE THEIR CLOUDS. ОБЛАЧНЫЕ ВЫЧИСЛЕНИЯ ГЛАЗАМИ ПЕНТЕСТЕРА, ЮРИЙ ГОЛЬЦЕВ, СЕ...
ABUSE THEIR CLOUDS. ОБЛАЧНЫЕ ВЫЧИСЛЕНИЯ ГЛАЗАМИ ПЕНТЕСТЕРА, ЮРИЙ ГОЛЬЦЕВ, СЕ...ABUSE THEIR CLOUDS. ОБЛАЧНЫЕ ВЫЧИСЛЕНИЯ ГЛАЗАМИ ПЕНТЕСТЕРА, ЮРИЙ ГОЛЬЦЕВ, СЕ...
ABUSE THEIR CLOUDS. ОБЛАЧНЫЕ ВЫЧИСЛЕНИЯ ГЛАЗАМИ ПЕНТЕСТЕРА, ЮРИЙ ГОЛЬЦЕВ, СЕ...
 
Best of Positive Research 2013
Best of Positive Research 2013Best of Positive Research 2013
Best of Positive Research 2013
 
Web-style Wireless IDS attacks, Sergey Gordeychik
Web-style Wireless IDS attacks, Sergey GordeychikWeb-style Wireless IDS attacks, Sergey Gordeychik
Web-style Wireless IDS attacks, Sergey Gordeychik
 
G. Gritsai, A. Timorin, Y. Goltsev, R. Ilin, S. Gordeychik, and A. Karpin, “S...
G. Gritsai, A. Timorin, Y. Goltsev, R. Ilin, S. Gordeychik, and A. Karpin, “S...G. Gritsai, A. Timorin, Y. Goltsev, R. Ilin, S. Gordeychik, and A. Karpin, “S...
G. Gritsai, A. Timorin, Y. Goltsev, R. Ilin, S. Gordeychik, and A. Karpin, “S...
 
SCADA StrangeLove: Too Smart Grid in da Cloud [31c3]
SCADA StrangeLove: Too Smart Grid in da Cloud [31c3]SCADA StrangeLove: Too Smart Grid in da Cloud [31c3]
SCADA StrangeLove: Too Smart Grid in da Cloud [31c3]
 
Pt infosec - 2014 - импортозамещение
Pt   infosec - 2014 - импортозамещениеPt   infosec - 2014 - импортозамещение
Pt infosec - 2014 - импортозамещение
 
SCADA StrangeLove Kaspersky SAS 2014 - LHC
SCADA StrangeLove Kaspersky SAS 2014 - LHCSCADA StrangeLove Kaspersky SAS 2014 - LHC
SCADA StrangeLove Kaspersky SAS 2014 - LHC
 
Firebird Interbase Database engine hacks or rtfm
Firebird Interbase Database engine hacks or rtfmFirebird Interbase Database engine hacks or rtfm
Firebird Interbase Database engine hacks or rtfm
 
SCADA StrangeLove 2: We already know
SCADA StrangeLove 2:  We already knowSCADA StrangeLove 2:  We already know
SCADA StrangeLove 2: We already know
 
Internet connected ICS/SCADA/PLC
Internet connected ICS/SCADA/PLCInternet connected ICS/SCADA/PLC
Internet connected ICS/SCADA/PLC
 
SCADA deep inside:protocols and software architecture
SCADA deep inside:protocols and software architectureSCADA deep inside:protocols and software architecture
SCADA deep inside:protocols and software architecture
 
Techniques of attacking ICS systems
Techniques of attacking ICS systems Techniques of attacking ICS systems
Techniques of attacking ICS systems
 
Positive Technologies Application Inspector
Positive Technologies Application InspectorPositive Technologies Application Inspector
Positive Technologies Application Inspector
 
Database honeypot by design
Database honeypot by designDatabase honeypot by design
Database honeypot by design
 
Positive Technologies Application Inspector
Positive Technologies Application InspectorPositive Technologies Application Inspector
Positive Technologies Application Inspector
 
Black Hat: XML Out-Of-Band Data Retrieval
Black Hat: XML Out-Of-Band Data RetrievalBlack Hat: XML Out-Of-Band Data Retrieval
Black Hat: XML Out-Of-Band Data Retrieval
 
ICS/SCADA/PLC Google/Shodanhq Cheat Sheet v2
ICS/SCADA/PLC Google/Shodanhq Cheat Sheet v2ICS/SCADA/PLC Google/Shodanhq Cheat Sheet v2
ICS/SCADA/PLC Google/Shodanhq Cheat Sheet v2
 

Positive Technologies WinCC Security Hardening Guide

  • 1. SIEMENS SIMATIC WINCC 7.X SCADA SECURITY HARDENING GUIDE PUBLIC BETA 27 DEC 2012
  • 2. CONTENTS LEGAL NOTES........................................................................................................................................................ 4 1. OPERATING SYSTEM CONFIGURATION .............................................................................................. 5 1.1 Use compatible Windows version .......................................................................................................... 5 1.2 Ensure appropriate Windows language settings.............................................................................. 5 1.3 Ensure the latest Windows updates are installed ........................................................................... 5 1.4 Enable unsigned drivers installation..................................................................................................... 5 1.5 Set user interface restrictions ................................................................................................................ 5 1.6 Set system parameters according to the vendor's requirements ............................................. 6 1.7 Ensure control of system group membership restrictions ........................................................... 6 2. SYSTEM NETWORK PARAMETERS CONFIGURATION ..................................................................... 7 2.1 Disable access to external networks .................................................................................................... 7 2.2 Do not install Novell Netware clients ................................................................................................... 7 3. DBMS CONFIGURATION ............................................................................................................................ 7 3.1 Ensure installation of the latest security updates for Microsoft SQL 2005 ........................... 7 3.2 Use strong system administrator password ...................................................................................... 7 3.3 Provide SIMATIC HMI users with SQL access rights ...................................................................... 7 4. ADDITIONAL SECURITY TOOLS ............................................................................................................. 8 4.1 Install compatible antivirus software ................................................................................................... 8 4.2 Use up-to-date antivirus software ........................................................................................................ 8 5. SIMATIC WINCC (SYSTEM PARAMETERS) ........................................................................................ 8 5.1 Do not use the WinCC DiagAgent (CCDiagAgent) application in production systems ...... 8 5.2 Ensure WinCC Runtime launch as a system service ...................................................................... 8 5.3 Disable WinCC Runtime autostart cancelling .................................................................................... 8 6. SIMATIC WINCC (SIMATIC LOGON CONFIGURATIONS) ............................................................ 9 6.1 Set logon time-out ...................................................................................................................................... 9 6.2 Enable password change reminder ....................................................................................................... 9 7. SIMATIC WINCC (ACCESS CONFIGURATIONS) ...........................................................................10 7.1 Change default passwords for demonstration accounts .............................................................10 7.2 Change administrator’s default password ........................................................................................10 7.3 Control password strength for HMI access accounts ...................................................................10 7.4 Restrict management group membership........................................................................................10 7.5 Disable access via local groups ............................................................................................................11 8. SIMATIC WINCC (EVENTS LOGGING) ..............................................................................................11 8.1 Enable logon events logging to archive ............................................................................................11
  • 3. 8.2 Enable logon events logging to the Windows system log ..........................................................11 9. SIMATIC WINCC (PROJECT CONTROL) ............................................................................................11 9.1 Disable interface management hotkeys ...........................................................................................11 10. SIMATIC WINCC (WEBNAVIGATOR — SCREEN PUBLISHING) ...............................................12 10.1 Publish only necessary screens ...............................................................................................12 SIEMENS WINCC 7.X /SECURITY HARDENING GUIDE Page 3 of 12
  • 4. LEGAL NOTES The copyright on the materials contained in this documentation belong to the Closed Joint Stock Company “Positive Technologies” and is protected in accordance with the applicable rules of national law of the Russian Federation and of International law exclusive of any choice of any other local law rules. The quoting and use of these materials are allowed only in compliance with the legislation stipulated above and with obligatory indication of the copyright holder and of the source of borrowing. The Closed Joint Stock Company “Positive Technologies” shall not be responsible for the consequences resulting from the use of these materials or inability of such use. The Closed Joint Stock Company “Positive Technologies” holds no responsibility for any decisions made by users on the basis of these materials and for any results obtained according to such decisions. SIEMENS WINCC 7.X /SECURITY HARDENING GUIDE Page 4 of 12
  • 5. 1. OPERATING SYSTEM CONFIGURATION 1.1 Use compatible Windows version Install WinCC on those operating systems that are supported by the vendor. Recommendations: To verify whether the Windows version is compatible, use the list http://cache.automation.siemens.com/dnl/zQ/zQzMjEzAAAA_21927773_FAQ/WinCC_V70_compatibilit y_list_e.pdf. 1.2 Ensure appropriate Windows language settings WinCC is available only for operating systems with the following language interfaces:  German  English  French  Italian  Spanish  Multilingual User Interface (MUI)* *For MUI systems, the OS language should be English. Recommendations: To make sure the OS language settings are appropriate, verify the language used in the system: Start -> Control Panel -> Regional and Language Options. 1.3 Ensure the latest Windows updates are installed For supporting Windows up-to-date security level, it is required to check for updates regularly. Recommendations: Ensure that all the latest OS updates have been installed. 1.4 Enable unsigned drivers installation For WinCC proper functioning on a Windows operating system, it is necessary to disable the default check for drivers’ signatures on installation. Recommendations: Verify that the installation of unsigned drivers is allowed. 1.5 Set user interface restrictions It is necessary to restrict user actions performed via Windows interface in the WinCC environment. It is required to disable such hotkeys as Ctr+Alt+Del, Alt+Esc, Alt+Tab, Ctl+Esc. Recommendations: SIEMENS WINCC 7.X /SECURITY HARDENING GUIDE Page 5 of 12
  • 6. To verify the status of restriction on WinCC user interface, go to WinCC Explorer -> Computer properties -> Parameters -> Disable Keys. Verify the following registry key values: For 64-bit Windows systems: [HKEY_LOCAL_MACHINESOFTWAREWow6432NodeSiemensWinCCWinlogonPermissions] "AllowShutdown"=dword:00000001 "AllowLogout"=dword:00000001 "AllowCtlAltDel"=dword:00000001 "AllowAltEsc"=dword:00000000 "AllowAltTab"=dword:00000001 "AllowCtlEsc"=dword:00000000 For 64-bit Windows systems: [HKEY_LOCAL_MACHINESOFTWARE SiemensWinCCWinlogonPermissions] "AllowShutdown"=dword:00000001 "AllowLogout"=dword:00000001 "AllowCtlAltDel"=dword:00000001 "AllowAltEsc"=dword:00000000 "AllowAltTab"=dword:00000001 "AllowCtlEsc"=dword:00000000 1.6 Set system parameters according to the vendor's requirements For WinCC proper functioning on a Windows operating system, it is necessary to configure the operating system according to the vendor's requirements. Configure following parameters: - User group - Registry settings and rights - Firewall settings - DCOM settings - File system rights Recommendations: Ensure that the system parameters are set according to the vendor's requirements. You can use SIMATIC Security Control (SecurityController.exe) tool to automate configuration process. 1.7 Ensure control of system group membership restrictions It is required to ensure control over the membership restrictions of such system groups as Administrator, Server Operators, and Power Users. Recommendations: Ensure that membership restrictions set for the specified system groups are correct. SIEMENS WINCC 7.X /SECURITY HARDENING GUIDE Page 6 of 12
  • 7. 2. SYSTEM NETWORK PARAMETERS CONFIGURATION 2.1 Disable access to external networks For maximum security, it is necessary to divide networks by the following categories: networks for management, for data transmission, and main purpose networks. So, if an attacker penetrates into one of the networks, system compromise may be avoided. Recommendations: To verify external networks availability, use the netstat application with the -rn parameters. 2.2 Do not install Novell Netware clients Avoid installing WinCC on the system together with the Novell client's software. Such an installation may result in failure to log into the Novell system or to lock the keyboard in the execution environment. Recommendations: Ensure that the Netware client's software or Microsoft client for Netware are not used. 3. DBMS CONFIGURATION 3.1 Ensure installation of the latest security updates for Microsoft SQL 2005 For supporting up-to-date security level of SQL Server, it is required to check for updates regularly. Recommendations: Ensure that all the latest SQL Server updates have been installed. 3.2 Use strong system administrator password Only the ASCII characters can be used for the password of the SQL Server system administrator. The password should contain at least 14 characters. Recommendations: Ensure that a strong password is used for the system administrator account. 3.3 Provide SIMATIC HMI users with SQL access rights To receive access to WinCC in Microsoft SQL Server 2005, the SIMATIC HMI group members should have appropriate rights. For provision of the access rights, it is required to add users to the group SQLServer2005MSSQLUser$<COMPUTERNAME>$WINCC. Recommendations: Verify that SIMATIC HMI users have been provided with SQL Server access rights. SIEMENS WINCC 7.X /SECURITY HARDENING GUIDE Page 7 of 12
  • 8. 4. ADDITIONAL SECURITY TOOLS 4.1 Install compatible antivirus software It is recommended to install only that antivirus software which is compatible with the WinCC software installed on your operating system. Recommendations: To ensure that the installed antivirus software is compatible, use the list http://cache.automation.siemens.com/dnl/zQ/zQzMjEzAAAA_21927773_FAQ/WinCC_V70_compatibilit y_list_e.pdf. 4.2 Use up-to-date antivirus software The antivirus software should be active and should use an up-to-date database. Recommendations: Verify that antivirus software is active. To ensure that the antivirus software database is up-to-date, use recommendations of antivirus software vendor. 5. SIMATIC WINCC (SYSTEM PARAMETERS) 5.1 Do not use the WinCC DiagAgent (CCDiagAgent) application in production systems WinCC DiagAgent (CCDiagAgent) is used to control and diagnose Simatic WinCC, operating system, and DBMS. By default, the application does not require authorization, which may allow a remote attacker to alter system configuration and execute arbitrary code. Ensure that this application has been removed or is not running on production systems. Recommendations: To ensure the application is not used in production systems, it is required to regularly check that there is no CCDiagAgent.exe among the processes running on the operating system. Use SIMATIC Diagnostics Tool or the SIMATIC Analyser. http://www.siemens.com/corporate- technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-223158.pdf 5.2 Ensure WinCC Runtime launch as a system service It is required to ensure that WinCC Runtime is launched as a system service. Recommendations: To ensure that WinCC Runtime is launched as a system service, verify service settings available here: Project properties -> Operation mode -> Service. 5.3 Disable WinCC Runtime autostart cancelling If autostart is configured for the WinCC project, it is required to ensure that the Allow "Cancel" during activation option of the AutoStart Configuration application is disabled. Recommendations: SIEMENS WINCC 7.X /SECURITY HARDENING GUIDE Page 8 of 12
  • 9. To ensure the specified option is disabled, verify which settings are enabled by launching the AutoStart Configuration application available here: Program FilesSiemensWinCCbinAutoStartRT.exe. Additionally, verify the EnableBreak value in the Windows registry. [HKEY_LOCAL_MACHINESOFTWAREWow6432NodeSiemensWinCCAutoStartWinCC] "ProjectName"="C:UsersPublicDocumentsSiemensWinCCProjects123123.MCP" "Activate"=dword:00000000 (Activate project at startup) "EnableBreak"=dword:00000001. "AllUsers"=dword:00000000 (available for all users) "NCGM"=dword:00000000 "RedProject"=dword:00000000 "RedProjectName"="" "StartInServiceMode"=dword:00000000 6. SIMATIC WINCC (SIMATIC LOGON CONFIGURATIONS) 6.1 Set logon time-out If the SIMATIC LOGON application is used, it is necessary to activate the automatic logoff function and set a logon time-out. Recommendations: To ensure the logon time-out is set, verify the SIMATIC LOGON settings using the following configuration file: C:Documents and Settings{All UsersDocuments} SiemensSIMATICLogonsettingsslsettings.ini. Configuration file control parameters: [Screensaver] UseScreensaver=1 — Used SIMATIC Logon automatic logoff WaitTime=46620 — Delay Time in Seconds TimeToLogout=30 — Time until automatic logoff 6.2 Enable password change reminder If the SIMATIC LOGON application is used, it is necessary to activate the function of the password change reminder. The relevant option should be configured in such a way so that the reminder appears not earlier than two months prior to the password change. Recommendations: To ensure the password change reminder is enabled, verify the SIMATIC LOGON parameters using the following configuration file: C:Documents and Settings{All UsersDocuments} SiemensSIMATICLogonsettingsslsettings.ini. Configuration file control parameters: [Config] Reminder=0 — Days for reminder of password expiration SIEMENS WINCC 7.X /SECURITY HARDENING GUIDE Page 9 of 12
  • 10. 7. SIMATIC WINCC (ACCESS CONFIGURATIONS) 7.1 Change default passwords for demonstration accounts It is required to change the following default passwords for the WinCC demo accounts:  winccd/winccpass  wincce/winccpass  DMUser/Data&Pass Recommendations: Ensure the default passwords for the demo accounts have been changed. It’s recommended to delete this accounts in production environment Links: http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=45027800&c aller=view 7.2 Change administrator’s default password It is required to change the following WinCC administrator password created by default: Administrator/Administrator. Recommendations: To ensure the default password is not used for the administrator account, verify the WinCC user list via the following database query: SELECT * FROM {database_name}.dbo.PW_USER Use automatic tools to control password complexity. 7.3 Control password strength for HMI access accounts It is necessary to control password strength for group members possessing the rights to change such system parameters as:  User administration  Value input  Process controlling Recommendations: To verify WinCC user rights, use the following database query: SELECT * FROM {database_name}.dbo.PW_USER Use automatic tools to control password complexity. 7.4 Restrict management group membership Control membership in the groups possessing the rights to change such system parameters as:  User administration SIEMENS WINCC 7.X /SECURITY HARDENING GUIDE Page 10 of 12
  • 11. Value input  Process controlling Recommendations: To verify WinCC user rights, use User Administrator (PassCS.exe) tool. 7.5 Disable access via local groups A server with installed WebNavigator should be available only for groups of the same domain. Recommendations: To ensure that access via local groups is disabled, verify the following option configuration: WinCC Web Settings -> Session Logon/Logoff -> Disable local groups of SIMATIC Logon. 8. SIMATIC WINCC (EVENTS LOGGING) 8.1 Enable logon events logging to archive WebNavigator Client logon and logoff successful attempts should be logged (logging of the system messages No. 1012400 or 1012401). Recommendations: To ensure that the event logging is enabled, verify the following option configuration: WinCC Web Settings -> Session Logon/Logoff -> Enable WinCC system messages. 8.2 Enable logon events logging to the Windows system log It is required to log successful logon sessions to the Windows system log. Recommendations: To ensure that the event logging is enabled, verify the following option configuration: WinCC Web Settings -> Session Logon/Logoff -> Enable event log messages. 9. SIMATIC WINCC (PROJECT CONTROL) 9.1 Disable interface management hotkeys Interface management shortcut keys should be disabled for each project. Hotkeys (Alt+F4, Resize, Move, Minimize, Maximize, etc.) for windows management should be disabled in the WinCC project settings. Recommendations: To verify the status of WinCC user interface restrictions, go to WinCC Explorer -> Computer properties -> Graphics Runtime. SIEMENS WINCC 7.X /SECURITY HARDENING GUIDE Page 11 of 12
  • 12. 10. SIMATIC WINCC (WEBNAVIGATOR — SCREEN PUBLISHING) 10.1 Publish only necessary screens It is required to control project screens published via WebNavigator. Recommendations: To verify only necessary screens are published, go to WinCCExplorer -> WebNavigator -> WinCC Web Publishing Wizard -> Select pictures. SIEMENS WINCC 7.X /SECURITY HARDENING GUIDE Page 12 of 12