SlideShare una empresa de Scribd logo
1 de 19
CSME/SARCLE, ENSIC Nancy, October 22-24, 2012
Session 1: Tools for Defining Impacts and Liabilities


   Validation of an On-Site Component-
   Specific Detection Method for Volatile
   Organic Components: EnISSA-MIP
   Pieter Buffel (pieter.buffel@enissa.com);
   Wouter Vandeputte; Samuel Van Herreweghe; Wim Vansina and
   Mark Van Straaten
   (EnISSA – MAVA, BELGIUM)

   B. Van Goidsenhoven (bert.van.goidsenhoven@ovam.be);
   Inge De Vrieze and Veerle Labeeuw
   (OVAM, The Public Waste Agency of Flanders, BELGIUM)
Validation of an On-Site Component-Specific
Detection Method for Volatile Organic Components:
EnISSA-MIP
   1.   Introduction Citychlor
   2.   EnISSA MIP
   3.   Pilot study field results
   4.   Cost comparison
   5.   Conclusions
1. Introduction


      improve the quality and minimize the pollution of soil and groundwater by
      developing an integrated approach to tackle the threats caused
            by contamination with chlorinated solvents in urban areas.


9 partners from Flanders, Netherlands, France, Germany




            Lead partner: OVAM

                    The Public Waste Agency of
                    Flanders, Belgium


   www.enissa.com
  www.enissa.com
1. Introduction
Research budget 5.2 M€ (50% funded by Interreg IV NWE project)
Focus on:

   - Social-economical aspects
   - Remediation techniques
   - Characterisation techniques

                 Pilot project 2:
                 Validation & demonstration of an
                 innovative site characterisation tool




    www.enissa.com
   www.enissa.com
2. MIP
                         Membrane Interface Probe
                      Screening tool for VOC
                      Cone: heated block and hydrophobic semi permeable membrane
                      Direct push
                      Local heating of soil
                      Volatilization and diffusion through membrane
                      Inert carrier gas & transport to detector

                                         Typical setup: Combination of three detectors:
                                                    * Dry electrolytic detector (DELCD) or


                                                      Halogen specific detector (XSD)
                                                    * Photo ionisation detector (PID)
                                                    * Flame ionisation detector (FID)


  www.enissa.com
 www.enissa.com
2. MIP  EnISSA MIP
    PID, FID, DELCD & XSD
    → Summation-detectors: no information on individual contaminants: polluent cocktails!
    → respons is component specific  quantification difficult
    → detection limit > groundwater clean-up values in Flanders : μg/l


         EnISSA MIP
•     MIP with dedicated GC-MS detection combined with proprietary
    contaminant sampling technology
•     GC-MS: Optimized for field measurements:
         * ruggedized
         * cycle/analysis time: 1 min
          1 measurement per 30 cm at probing speed of 30 cm/min
         * up to 12 compounds simultaneously

       Highly detailed profiles for individual
              compounds on ppb level
     www.enissa.com
    www.enissa.com
2. EnISSA MIP




  Tetrachloroethylene       Vinylchloride       1,2 dichloroethylene        PID         Soil Conductivity


                Measurement of individual components                   Measurement of    Measurement of
                                                                       sum parameters    soil parameters


  www.enissa.com
 www.enissa.com
3. Pilot Study Field results
Site description:

* Location: Kortrijk (Belgium)
* Former spinning and weaving mill
* Contaminants: CVOC & BTEX
* Three sources, possible DNAPL




Purpose: Validation of the EnISSA MIP by traditional sampling
MIP configuration:
MIP Controller Model MP6505 / Field Instrument Model FI6000
40 m unheated Teflon-Peek trunkline
35 ml/min N2 flow

     www.enissa.com
    www.enissa.com
3. Field results: EnISSA MIP 10004




                   EnISSA  detailed soil profiles for individual compounds
                          * low detection limit
  www.enissa.com
 www.enissa.com           * each 30 cm or less: characterization of up to 12 compounds
3. Field results: Source area: DCE




  www.enissa.com
 www.enissa.com
3. Field results: Source area: DCE




  www.enissa.com
 www.enissa.com
3. Field results: Source area

• EnISSA gives a soil/ground water profile for each component:

    •  profile confirmed by soil & groundwater samples

•EnISSA gives indication of presence of DNAPL:

    •  visually determined during ground water sampling
       soil & groundwater samples also indicate presence of DNAPL

•EnISSA concentrations correlate with groundwater concentrations:

       remarks:
           ! EnISSA measures soil, groundwater & pure product phase
           ! EnISSA is calibrated with aqueous solution




  www.enissa.com
 www.enissa.com
3. Field results: Plume area: DCE




                                Inaccurate filter
                                location!




  www.enissa.com
 www.enissa.com
3. Field results




      * contribution of the adsorbed contaminants which will be
      measured by EnISSA but not by the groundwater samples
      * EnISSA results vs. groundwater results: order of magnitude is
      comparable  semi-quantitative
  www.enissa.com
 www.enissa.com
4. Cost comparison: Project cost
             20000
                                                                                                      25000
             18000                EnISSA campaign
             16000
                                  traditional campaign
                                                                                                      20000
             14000
             12000
  Cost (€)




                                                                                                              Cost ($)
                                                                                                      15000
             10000
              8000                                                                                    10000
              6000
              4000                                                                                    5000
              2000
                 0                                                                                    0
                     EnISSA MIP




                                      groundwater



                                                    groundwater



                                                                  analysis




                                                                                      total project
                                                                             report
                                                                  soil/GW
                                                      sampling
                                         wells



                                                        wells




  www.enissa.com
 www.enissa.com                                                                           cost
4. Cost comparison: information meter
                 25000


                 20000   Cost ($)


                 15000


                 10000


                 5000


                 0
 total project
     cost




  www.enissa.com
 www.enissa.com
5. Conclusions
                   ARE WE THERE YET?




  www.enissa.com
 www.enissa.com
5. Conclusions

entire delineation of contamination: source + plume
         EnISSA MIP measures on ppb level
         → source and plume
         (Conventional MIP measures on sub-ppm level)

    - Order of magnitude = groundwater sample  high quality screening tool -
“On site” information on pollution cocktails:
         EnISSA MIP measures individual compounds in contrast to the sum-detectors used
         in conventional MIP

         - Each 30 cm up to 12 compounds can be distinguished -


strategic sampling well locations:
         The entire delineation of source and plume obtained by EnISSA MIP makes it possible
         to place sampling wells at strategic locations reducing sampling costs and time.


   www.enissa.com
  www.enissa.com
More information:


                   www.ovam.be
                  www.CityChlor.eu
                  Info@citychlor.eu


                  www.EnISSA.com
                  info@EnISSA.com

 www.enissa.com
www.enissa.com

Más contenido relacionado

Similar a EnISSA CSME 2012

Nick - Benefits of Using Combined Bathymetry and Side Scan Sonar in Shallow W...
Nick - Benefits of Using Combined Bathymetry and Side Scan Sonar in Shallow W...Nick - Benefits of Using Combined Bathymetry and Side Scan Sonar in Shallow W...
Nick - Benefits of Using Combined Bathymetry and Side Scan Sonar in Shallow W...Codevintec Italiana srl
 
Exposure assessment for the wider environment
Exposure assessment for the wider environment Exposure assessment for the wider environment
Exposure assessment for the wider environment Anna Sapundzhieva
 
Zebra - TRIAD-ES Joint Presentation
Zebra - TRIAD-ES Joint PresentationZebra - TRIAD-ES Joint Presentation
Zebra - TRIAD-ES Joint PresentationZEBRA Environmental
 
Technical calculations for the biological treatment plant
Technical calculations for the biological treatment plantTechnical calculations for the biological treatment plant
Technical calculations for the biological treatment plantAlex Tagbo
 
Green, nature-based water infrastructure: The EIP Water "NatureWAT" Action Gr...
Green, nature-based water infrastructure: The EIP Water "NatureWAT" Action Gr...Green, nature-based water infrastructure: The EIP Water "NatureWAT" Action Gr...
Green, nature-based water infrastructure: The EIP Water "NatureWAT" Action Gr...EIP Water
 
Columbia Technologies High-Resolution Remedial Design Characterization -SOHL ...
Columbia Technologies High-Resolution Remedial Design Characterization -SOHL ...Columbia Technologies High-Resolution Remedial Design Characterization -SOHL ...
Columbia Technologies High-Resolution Remedial Design Characterization -SOHL ...John Sohl
 
Urban Dynamics Monitoring: An Innovative Economic Activity Density Indicator...
Urban Dynamics Monitoring: An Innovative Economic Activity Density Indicator...Urban Dynamics Monitoring: An Innovative Economic Activity Density Indicator...
Urban Dynamics Monitoring: An Innovative Economic Activity Density Indicator...Nicolas Lachance-Bernard
 
IRJET- Ground Water Control Method Simulation in Sphinx Area
IRJET-  	  Ground Water Control Method Simulation in Sphinx AreaIRJET-  	  Ground Water Control Method Simulation in Sphinx Area
IRJET- Ground Water Control Method Simulation in Sphinx AreaIRJET Journal
 
Simulating the dispersion of traffic emissions at the microscale
Simulating the dispersion of traffic emissions at the microscaleSimulating the dispersion of traffic emissions at the microscale
Simulating the dispersion of traffic emissions at the microscaleIES / IAQM
 
Carbon analysis cod toc bod sensor-wtw
Carbon analysis cod toc bod sensor-wtwCarbon analysis cod toc bod sensor-wtw
Carbon analysis cod toc bod sensor-wtwENVIMART
 
Fees & subsidies, the pillars of the French Water Agencies
Fees & subsidies, the pillars of the French Water AgenciesFees & subsidies, the pillars of the French Water Agencies
Fees & subsidies, the pillars of the French Water AgenciesOECD Environment
 
Greenbass, regulation of sequenced aeration for activated sludge
Greenbass, regulation of sequenced aeration for activated sludgeGreenbass, regulation of sequenced aeration for activated sludge
Greenbass, regulation of sequenced aeration for activated sludgeDegrémont
 
CO2 in MAC - History, Present & Future
CO2 in MAC - History, Present & FutureCO2 in MAC - History, Present & Future
CO2 in MAC - History, Present & FutureUNEP OzonAction
 
LCA and risk assessment of sewage sludge application to land compared to pho...
 LCA and risk assessment of sewage sludge application to land compared to pho... LCA and risk assessment of sewage sludge application to land compared to pho...
LCA and risk assessment of sewage sludge application to land compared to pho...European Sustainable Phosphorus Platform
 
Evaluation of a hybrid forward osmosis system
Evaluation of a hybrid forward osmosis systemEvaluation of a hybrid forward osmosis system
Evaluation of a hybrid forward osmosis systemacciona
 

Similar a EnISSA CSME 2012 (20)

Nick - Benefits of Using Combined Bathymetry and Side Scan Sonar in Shallow W...
Nick - Benefits of Using Combined Bathymetry and Side Scan Sonar in Shallow W...Nick - Benefits of Using Combined Bathymetry and Side Scan Sonar in Shallow W...
Nick - Benefits of Using Combined Bathymetry and Side Scan Sonar in Shallow W...
 
Exposure assessment for the wider environment
Exposure assessment for the wider environment Exposure assessment for the wider environment
Exposure assessment for the wider environment
 
Zebra - TRIAD-ES Joint Presentation
Zebra - TRIAD-ES Joint PresentationZebra - TRIAD-ES Joint Presentation
Zebra - TRIAD-ES Joint Presentation
 
Technical calculations for the biological treatment plant
Technical calculations for the biological treatment plantTechnical calculations for the biological treatment plant
Technical calculations for the biological treatment plant
 
Presentazione Pierluigi Cau, 24-05-2012
Presentazione Pierluigi Cau, 24-05-2012Presentazione Pierluigi Cau, 24-05-2012
Presentazione Pierluigi Cau, 24-05-2012
 
Green, nature-based water infrastructure: The EIP Water "NatureWAT" Action Gr...
Green, nature-based water infrastructure: The EIP Water "NatureWAT" Action Gr...Green, nature-based water infrastructure: The EIP Water "NatureWAT" Action Gr...
Green, nature-based water infrastructure: The EIP Water "NatureWAT" Action Gr...
 
Harsh lab tecnalia windeurope 180927
Harsh lab tecnalia windeurope 180927Harsh lab tecnalia windeurope 180927
Harsh lab tecnalia windeurope 180927
 
Columbia Technologies High-Resolution Remedial Design Characterization -SOHL ...
Columbia Technologies High-Resolution Remedial Design Characterization -SOHL ...Columbia Technologies High-Resolution Remedial Design Characterization -SOHL ...
Columbia Technologies High-Resolution Remedial Design Characterization -SOHL ...
 
Ragab R 1 - UEI Day 1 - Kochi Jan18
Ragab R 1 - UEI Day 1 - Kochi Jan18Ragab R 1 - UEI Day 1 - Kochi Jan18
Ragab R 1 - UEI Day 1 - Kochi Jan18
 
Urban Dynamics Monitoring: An Innovative Economic Activity Density Indicator...
Urban Dynamics Monitoring: An Innovative Economic Activity Density Indicator...Urban Dynamics Monitoring: An Innovative Economic Activity Density Indicator...
Urban Dynamics Monitoring: An Innovative Economic Activity Density Indicator...
 
IRJET- Ground Water Control Method Simulation in Sphinx Area
IRJET-  	  Ground Water Control Method Simulation in Sphinx AreaIRJET-  	  Ground Water Control Method Simulation in Sphinx Area
IRJET- Ground Water Control Method Simulation in Sphinx Area
 
Simulating the dispersion of traffic emissions at the microscale
Simulating the dispersion of traffic emissions at the microscaleSimulating the dispersion of traffic emissions at the microscale
Simulating the dispersion of traffic emissions at the microscale
 
Carbon Benefits4
Carbon Benefits4Carbon Benefits4
Carbon Benefits4
 
Carbon Benefits4
Carbon Benefits4Carbon Benefits4
Carbon Benefits4
 
Carbon analysis cod toc bod sensor-wtw
Carbon analysis cod toc bod sensor-wtwCarbon analysis cod toc bod sensor-wtw
Carbon analysis cod toc bod sensor-wtw
 
Fees & subsidies, the pillars of the French Water Agencies
Fees & subsidies, the pillars of the French Water AgenciesFees & subsidies, the pillars of the French Water Agencies
Fees & subsidies, the pillars of the French Water Agencies
 
Greenbass, regulation of sequenced aeration for activated sludge
Greenbass, regulation of sequenced aeration for activated sludgeGreenbass, regulation of sequenced aeration for activated sludge
Greenbass, regulation of sequenced aeration for activated sludge
 
CO2 in MAC - History, Present & Future
CO2 in MAC - History, Present & FutureCO2 in MAC - History, Present & Future
CO2 in MAC - History, Present & Future
 
LCA and risk assessment of sewage sludge application to land compared to pho...
 LCA and risk assessment of sewage sludge application to land compared to pho... LCA and risk assessment of sewage sludge application to land compared to pho...
LCA and risk assessment of sewage sludge application to land compared to pho...
 
Evaluation of a hybrid forward osmosis system
Evaluation of a hybrid forward osmosis systemEvaluation of a hybrid forward osmosis system
Evaluation of a hybrid forward osmosis system
 

EnISSA CSME 2012

  • 1. CSME/SARCLE, ENSIC Nancy, October 22-24, 2012 Session 1: Tools for Defining Impacts and Liabilities Validation of an On-Site Component- Specific Detection Method for Volatile Organic Components: EnISSA-MIP Pieter Buffel (pieter.buffel@enissa.com); Wouter Vandeputte; Samuel Van Herreweghe; Wim Vansina and Mark Van Straaten (EnISSA – MAVA, BELGIUM) B. Van Goidsenhoven (bert.van.goidsenhoven@ovam.be); Inge De Vrieze and Veerle Labeeuw (OVAM, The Public Waste Agency of Flanders, BELGIUM)
  • 2. Validation of an On-Site Component-Specific Detection Method for Volatile Organic Components: EnISSA-MIP 1. Introduction Citychlor 2. EnISSA MIP 3. Pilot study field results 4. Cost comparison 5. Conclusions
  • 3. 1. Introduction improve the quality and minimize the pollution of soil and groundwater by developing an integrated approach to tackle the threats caused by contamination with chlorinated solvents in urban areas. 9 partners from Flanders, Netherlands, France, Germany Lead partner: OVAM The Public Waste Agency of Flanders, Belgium www.enissa.com www.enissa.com
  • 4. 1. Introduction Research budget 5.2 M€ (50% funded by Interreg IV NWE project) Focus on: - Social-economical aspects - Remediation techniques - Characterisation techniques Pilot project 2: Validation & demonstration of an innovative site characterisation tool www.enissa.com www.enissa.com
  • 5. 2. MIP Membrane Interface Probe  Screening tool for VOC  Cone: heated block and hydrophobic semi permeable membrane  Direct push  Local heating of soil  Volatilization and diffusion through membrane  Inert carrier gas & transport to detector Typical setup: Combination of three detectors: * Dry electrolytic detector (DELCD) or Halogen specific detector (XSD) * Photo ionisation detector (PID) * Flame ionisation detector (FID) www.enissa.com www.enissa.com
  • 6. 2. MIP  EnISSA MIP PID, FID, DELCD & XSD → Summation-detectors: no information on individual contaminants: polluent cocktails! → respons is component specific  quantification difficult → detection limit > groundwater clean-up values in Flanders : μg/l EnISSA MIP • MIP with dedicated GC-MS detection combined with proprietary contaminant sampling technology • GC-MS: Optimized for field measurements: * ruggedized * cycle/analysis time: 1 min  1 measurement per 30 cm at probing speed of 30 cm/min * up to 12 compounds simultaneously Highly detailed profiles for individual compounds on ppb level www.enissa.com www.enissa.com
  • 7. 2. EnISSA MIP Tetrachloroethylene Vinylchloride 1,2 dichloroethylene PID Soil Conductivity Measurement of individual components Measurement of Measurement of sum parameters soil parameters www.enissa.com www.enissa.com
  • 8. 3. Pilot Study Field results Site description: * Location: Kortrijk (Belgium) * Former spinning and weaving mill * Contaminants: CVOC & BTEX * Three sources, possible DNAPL Purpose: Validation of the EnISSA MIP by traditional sampling MIP configuration: MIP Controller Model MP6505 / Field Instrument Model FI6000 40 m unheated Teflon-Peek trunkline 35 ml/min N2 flow www.enissa.com www.enissa.com
  • 9. 3. Field results: EnISSA MIP 10004 EnISSA  detailed soil profiles for individual compounds * low detection limit www.enissa.com www.enissa.com * each 30 cm or less: characterization of up to 12 compounds
  • 10. 3. Field results: Source area: DCE www.enissa.com www.enissa.com
  • 11. 3. Field results: Source area: DCE www.enissa.com www.enissa.com
  • 12. 3. Field results: Source area • EnISSA gives a soil/ground water profile for each component: •  profile confirmed by soil & groundwater samples •EnISSA gives indication of presence of DNAPL: •  visually determined during ground water sampling  soil & groundwater samples also indicate presence of DNAPL •EnISSA concentrations correlate with groundwater concentrations:  remarks: ! EnISSA measures soil, groundwater & pure product phase ! EnISSA is calibrated with aqueous solution www.enissa.com www.enissa.com
  • 13. 3. Field results: Plume area: DCE Inaccurate filter location! www.enissa.com www.enissa.com
  • 14. 3. Field results * contribution of the adsorbed contaminants which will be measured by EnISSA but not by the groundwater samples * EnISSA results vs. groundwater results: order of magnitude is comparable  semi-quantitative www.enissa.com www.enissa.com
  • 15. 4. Cost comparison: Project cost 20000 25000 18000 EnISSA campaign 16000 traditional campaign 20000 14000 12000 Cost (€) Cost ($) 15000 10000 8000 10000 6000 4000 5000 2000 0 0 EnISSA MIP groundwater groundwater analysis total project report soil/GW sampling wells wells www.enissa.com www.enissa.com cost
  • 16. 4. Cost comparison: information meter 25000 20000 Cost ($) 15000 10000 5000 0 total project cost www.enissa.com www.enissa.com
  • 17. 5. Conclusions ARE WE THERE YET? www.enissa.com www.enissa.com
  • 18. 5. Conclusions entire delineation of contamination: source + plume EnISSA MIP measures on ppb level → source and plume (Conventional MIP measures on sub-ppm level) - Order of magnitude = groundwater sample  high quality screening tool - “On site” information on pollution cocktails: EnISSA MIP measures individual compounds in contrast to the sum-detectors used in conventional MIP - Each 30 cm up to 12 compounds can be distinguished - strategic sampling well locations: The entire delineation of source and plume obtained by EnISSA MIP makes it possible to place sampling wells at strategic locations reducing sampling costs and time. www.enissa.com www.enissa.com
  • 19. More information: www.ovam.be www.CityChlor.eu Info@citychlor.eu www.EnISSA.com info@EnISSA.com www.enissa.com www.enissa.com

Notas del editor

  1. NTERREG IVB NWE is a financial instrument of the European Union's Cohesion Policy. It funds projects which support transnational cooperation. The aim is to find innovative ways to make the most of territorial assets and tackle shared problems of Member States, regions and other authorities.