Megger designs and manufactures portable electric test equipment. Megger products help install, improve efficiency, reduce cost and extend the life of electrical assets. The Megger brand is so well known these days that some maintenance professionals incorrectly use it as a verb when they refer to doing an insulation test.
Megger manufactures hand-held test equipment as well as larger insulation testers, oil test equipment and low resistance ohmmeters.
Megger DETEX Voltage Detectors are available in seven models that cover a range from distribution class to transmission line voltages up to 550kV.
Megger cable fault location solutions include : low voltage TDR underground cable fault locators, surge generator fault locators, cable fault pinpointing, high voltage DC test sets and high voltage (11kV-33kV-66kV-132kV) underground cable fault locators.
2. Networking is profitable
not just social
MFT1700 series multifunction
installation tester
Now offering 3 and 2 wire non-trip loop test. See page 4
TDR1000/3 series cable
fault locators
Remove the mystery from cable fault location with this easy to use TDR. See page 32
Home automation is on everybody’s lips, and covers pages of
every magazine you read. Control is key. This principle has been
established in the industrial and commercial setting. Now it is
forging in to the domestic market with the advent of smart
metering and the governments insistence that new homes will
be carbon neutral in the future.
This more integrated approach to energy usage and
management is changing in the way electricians go about their
business. Already many new builds are fitted with a CAT 5e
network (also known as IEC Class F) usually to make it easy to
run a home computer network. But now with introduction of
active systems, such as lighting and heating control, energy
recovery and smart appliances, the electricians’ world is getting
more complex.
Megger has introduced the NET200, an inexpensive network
qualification tool that measures the performance of digital
networks. For more information see page 33.
MFT
MFT
1700 Series
Made in UK
All the 17th Edition and PAT products shown in this catalogue
are engineered and built at our factory in Dover. Megger
employs over 300 people at this site all of whom are busy
designing, developing, testing and assembling the products that
you use.
As a professional electrician, you have a right to demand the
very best electrical test equipment. By specifying Megger, not
only will you get the best, but you’ll also be supporting a great
British success story.
Innovative test and
measurement product of
the year
Measures the performance of a digital network. See page 33
PAT400 series downloading
portable appliance tester
The fastest tester in its class. See details on page 20.
Electrical
Electrical
test kits
test kits
Part P
kits P
Part
Combined
kits
loop and
RCD testers
Combined
loop & RCD
testers
Insulation
testers
Industrial
insulation
testers
The introduction of complexity is always an opportunity; an
opportunity for the industry to solve customers’ problems and
make money.
NET200 network qualification
tester
MFT
with
MFT with
certification
certification
Loop
testers
Finding faults is big business
RCD
testers
As you are aware, in our industry interruptions in power
supply is a major irritation for consumers. That’s why the
utility companies have imposed on them a limit to number of
customer hours that can be lost. Faults don’t only occur on the
HV distribution network, but are common in LV systems, due
to broken cables and poor joints. In addition, problems with
the mains and waste water pipes are becoming more and more
frequent as installations age.
In 2012, Megger acquired the biggest name in fault finding
test equipment, SEBAKMT. SEBAKMT brings to Megger
unquestionable expertise in the areas of cable condition
monitoring, sheath testing and fault location on both HV & LV
systems. It has introduced a new range of water leak detection
test equipment to the Megger portfolio for the first time.
In addition, the EasyLoc range of buried services and cable
avoidance tools now offer a sophisticated solution for tracing
a cable route or preparing a site - preventing those expensive
mistakes with a digger!
PATs
Certification
software
The TDR1000/3 was chosen by a panel of independent
industry specialists because it simplified the use of time
domain reflectometry for fault finding in LV cables.
The ease of use of the instrument was paramount in
the design criteria and resulted in this low cost solution
now being accessible to companies and contractors, who
would have previously looked to hire in dedicated fault
location specialists.
Meter
test box
Voltage
detector,
Solar tester
Accessories
For more information see page 31
Clamp and
multimeters
Don’t miss out!
Keep in touch with Megger
The warranty of many Megger
products can be upgraded to
three full years free of charge,
simply by registering the
purchase of the product. So
register your product to allow
us to offer you full technical
support and a free three-year
warranty.
Follow us on Twitter
at www.twitter.com/meggeruk
Watch our videos on YouTube
at www.youtube.com/meggeruk
Find us on Facebook
at www.facebook.com/meggeruk
Or visit our website at
www.megger.com/uk
Trying to decide which
Megger tester is best for
you?
Earth testers
Services
and leak
detectors
Why not call the Megger technical desk?
They’ll talk through your needs and the
way you work and help you make the
right decision for your business.
Call 01304 502 102
Cable fault
locator
Network
performance
tester
Prices
2
NEW PRODUCTS
VALUE FOR MONEY 3
3. Multifunction testers
MFT1700 series
The new MFT1700 series is tough,
even tougher than its popular
predecessor.
It won’t go bang when connected across phases, when it gets
dropped or bounced, when it’s used in the rain, when the
wrong range is selected or when accidentally connected to live
circuits – even with the test locked on!
Dust and rain proof to IP54, the MFT1700 series offers CAT IV
safety, meaning that you can use it in any environment without
a second thought. To make it more convenient, test buttons
are located at either end of the tester meaning you can use the
hand that is available to initiate testing, or you can use the new
CAT IV probe with test button if you prefer.
Even the carry case has been re-thought. There is now room
for not only for the meter and leads, but also a certificate pad,
wire cutters and a handful of screwdrivers.
Loop testing ranges
n and 3-wire non-trip 0.01Ω L-PE
2
n -PE 48 V to 280 V, 45 Hz to 65Hz
L
n on’t trip 6 A MCBs
W
n FC or PSCC measurement at same time as loop resistance
P
n High current loop testing L–L and L-N
n L-L 48 V to 480 V, 45 Hz to 65Hz dependant on model
n Auto-start loop test
Features
MFT
with
MFT with
certification
certification
Electrical
Electrical
test kits
test kits
RCD testing ranges
n uto RCD on MFT1720 and MFT1730
A
n CD ramp test to measure RCD trip current
R
n ype A, AC, B, Selective, programmable and 3-phase RCDs
T
dependant on model
n uto-start RCD test
A
Usefully the MFT1700 series has
test buttons at both ends of the
tester, so there is always one to
hand.
Continuity and resistance testing range
n 00 mA test with an option of 15 mA on MFT1720 and MFT1730
2
n uto-start continuity test
A
n asy test lead null�– stored even when switched off
E
n ast buzzer with adjustable threshold on MFT1720 and MFT1730
F
n Resistance measurement from 0.01 Ω to 99.9 kΩ
Insulation testing ranges
n 100 V, 250 V, 500 V and 1000 V dependant on model
n Test voltage displayed with insulation resistance measurement
n Adjustable buzzer threshold
n 25 V or 50 V test inhibit option
n rotection against live circuits up to 600 V even when test
P
locked�on
MFT
MFT
1700 Series
Colour-coded selection knobs
make sure you are in full control
of testing.
Large brightly backlit display
shows 2 parameters at a time
like loop impedance and PFC.
MFT1710 MFT1720 MFT1730
Communications on MFT1730
n Bluetooth downloading
n On-site option
n On-board memory
Rechargeable
n Cells rechargeable in situ on MFT1730
4
MULTIFUNCTION TESTERS
Continuity and
resistance range
200 mA
n
15 mA
Easy lead null
n
Auto-start continuity test
n
Adjustable buzzer threshold
n
n
n
n
n
n
n
n
n
n
n
Loop testing ranges
2-wire no-trip test L-PE
n
3-wire no-trip test L-PE
n
PSCC or PFC calculation displayed with
loop resistance
n
L-PE 48 V to 280 V, 45 Hz to 65 Hz
n
High current 2-wire testing
n
L-L / L-N 48 V to 480 V, 45 Hz to 65 Hz
L-N 48 V to 280 V, 45 Hz to 65 Hz
n
20 kA fault current
n
Zmax value
Calculated R1 + R2 value
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
RCD Testing range ½I, I and 5I Test
n
n
0º + 180º phase angle
n
n
Auto RCD testing
n
Ramp test
n
n
Type AC, A and S RCDs
n
n
Type B RCDs
Programmable RCDs
n
3-phase RCDs
n
Touch voltage display 0 - 230 V
n
n
n
n
n
n
n
n
n
n
n
10 V – 600 V a.c. and d.c. voltage
n
n
Trms measurement
Frequency 15 Hz – 400 Hz
n
n
Phase rotation
n
n
n
n
n
3-pole earth electrode
25 V and 50 V output voltage
Ground noise voltage check
n
n
n
Test lockout
Safe contact detector
Live circuit warning
Auto discharge
n
n
n
n
Analogue arc display
n
n
Large, easy-to-read, backlit display
n
n
Current measurement with
optional clamp
n
Test probe incorporating test button
n
Rechargeable
FREE calibration certificate
n
n
Warranty upgradeable to 3 years FREE
n
n
Dust and weatherproof to IP54
n
n
Safety rating
CAT IV 300 V
CAT IV 300 V
MFT series
accessories
n
n
n
n
n
n
Additional benefit
3-pole earth test on MFT1730
n Tests unconnected earth electrode resistance
1000 V
n
500 V
n
n
250 V
n
n
100 V
Test voltage display
n
n
Adjustable buzzer threshold
n
Intelligent safety system
Large bright dual parameter display
n Displays test voltage at the same time as insulation resistance
n Displays loop resistance and prospective fault current
n Enhanced viewing angle with intelligent backlight
Insulation test ranges
Earth testing
bit.ly/MFT1700
Voltage, phase rotation and frequency test range
n 10 V – 600 V a.c. / d.c. Trms on MFT1730
n Phase rotation on MFT1720 and MFT1730
n Frequency measurement 15 Hz to 400 Hz
n Touch voltage
Combined
loop RCD
testers
Insulation
testers
Voltage frequency and
phase rotation range
Scan with your smartphone
to see a demonstration of the
MFT1700 series or for more go to
Carry case has extra space so you
can store tools as well as test
leads, and even a certificate pad.
Part P
kits P
Part
Combined
kits
loop and
RCD testers
n
n
n
n
n
n
n
n
Loop
testers
RCD
testers
1001-975
3-wire 10 A fused test lead set
PATs
Certification
software
Meter
test box
1001-991
3-wire lead test set
Voltage
detector,
Solar tester
Accessories
Clamp and
multimeters
1001-810
3-wire earth electrode test set
Earth testers
Services
and leak
detectors
n
n
n
n
n
n
n
n
CAT IV 300 V
Industrial
insulation
testers
Cable fault
locator
1002-490
Red, blue and green
probes and clips
Network
performance
tester
Prices
MULTIFUNCTION TESTERS 5
4. Multifunction tester with certification software
MFT1730 On-site kit
Electrical test kits
MTK 300 series
And because you asked for it,
the MFT1730 is a rechargeable
instrument.
Megger MTK300 test kits give electrical contractors all they
need to perform electrical inspection and testing for single and
three phase operations. The kits consist of three instruments,
an MIT insulation tester, an LTW 2-wire non-trip earth loop
tester and an RCDT residual current device tester, each with
batteries fitted, in a smart case, with a full set of test leads
and calibration certificates. Three kits are available: MTK310,
MTK320 and MTK330.
Megger has changed the MFT options on result storage and
downloading. The MFT1730 offers you both On-site certificate
filling by sending your current result to a storage device, smartphone, PDA, notebook or laptop, there and then on site, or the
ability to store the results of your tests to download to your
computer off site. The MFT1730 uses Bluetooth technology
to communicate because it’s fast, effective and there are no
additional leads to store.
The MFT1730 On-site not only incorporates the form filling
software, but also includes the 3 pole earth resistance testing
kit, making it the best-value electrical testing package on the
market.
This is the ultimate
installation testing package,
with every-thing you need
in one tough easy to use
kit, 2 and 3-wire non-trip
loop testing, RCD testing,
insulation and continuity
testing with resistance
measurement, the MFT1730
adds True rms voltage
measurement, frequency
indication and phase
rotation. It even includes 3
pole earth testing to make
the kit complete.
It won’t go bang when...
n onnected across phases
c
n gets dropped
it
n sed in the rain
u
n ccidently testing live circuits
a
n electing the wrong test range
s
In a scene reminiscent of a James Bond movie, an
aluminium flight case recently came flying from the
window of a speeding van on the M69 motorway. The case
contained the latest in electrical testing technology, in the
form of a Megger MTK320 electrical contractors’ test kit
that had been stolen from a vehicle belonging to a leading
electrical training provider.
Despite a rough landing at speeds close to
70 mph, the three testers that make up the kit survived
their ordeal completely unscathed. A thorough check in the
Megger calibration laboratory showed that none of the
instruments needed even the slightest of adjustments.
Now that’s what we call tough!
MFT
MFT
1700 Series
MFT
with
MFT with
certification
certification
Electrical
Electrical
test kits
test kits
Part P
kits P
Part
Combined
kits
loop and
RCD testers
Combined
loop RCD
testers
MTK310 MTK320 MTK330
Insulation testing (see pages 10 and 11 for technical data) MIT310
n
MIT320
n
MIT330
Insulation
testers
n
Loop testing
(see pages 14 and 15 for technical data) LTW315
n
LTW325
n
LTW335
The complete on-site
testing kit includes all you
need
n
n
n
n
n
n
n
n
n
n
n
n
2-wire non-trip loop testing
3-wire non-trip loop testing
Fast 2-wire high current loop testing
Insulation testing
ontinuity and resistance
C
measurement
Single and 3-phase RCD testing
3 pole earth electrode testing
rue rms voltage and frequency
T
measurement
Phase rotation
Test results storage
owerSuite On-site certification
P
software
Rechargeable batteries
n
Industrial
insulation
testers
RCD testing
(see pages 16 and 17 for technical data) RCDT310
n
RCDT320
n
RCDT330
n
Loop
testers
n
n
n
n
n
n
n
RCD
testers
Rubber armoured
Weatherproof to IP54
Test leads included
Calibration certificates included
Warranty upgradeable to 3 years FREE
Batteries included
Smart brief case
n
n
n
n
n
n
n
n
n
n
n
n
n
n
PATs
Certification
software
MTK310: Standard electrical test kit
n MIT310 Insulation and continuity tester
n LTW315 Earth loop tester
Meter
test box
n RCDT310 RCD tester
MTK320: Advanced electrical test kit
Voltage
detector,
Solar tester
n IT320 Insulation and continuity tester with insulation and
M
continuity limit alarms
n LTW325 Earth loop tester with R1+R2 and Zmax measurement
n RCDT320 RCD tester with Programmable RCD testing capability
Accessories
MTK330: Result storage and downloading
test kit
Clamp and
multimeters
n IT330 Insulation and continuity tester as MIT320 but
M
with storage and downloading
Accessories
n TW335 Earth loop tester as LTW325 but with storage
L
and downloading
Earth testers
n CDT330 RCD tester as RCDT320 but with storage
R
and downloading
Services
and leak
detectors
For more information go to
Cable fault
locator
bit.ly/MTK300
For more information go to
Network
performance
tester
ICLAMP
100 A current clamp
bit.ly/MFT1730OS
Prices
6
MULTIFUNCTION TESTER
ELECTRICAL TEST KITS 7
5. Part P kits
PPK200 series
How it works
PPK210
Comprises the MIT310 insulation and continuity tester which
tests at 250 V, 500 V and 1000 V, and the LRCD210 Loop and
RCD tester. The kit comes complete with test leads, carry and
storage case and free calibration certificates.
The separation of live and dead testing that you find with
the PPK test kits is really helpful if electrical testing is not
your main line of business.
Selecting the tester for live circuits reminds you of
the safety implications of working with live circuits.
Meanwhile you know you are working with the best
when you insulation test with a Megger tester.
The MIT310 insulation tester and LRCD210 loop and RCD tester
will take the bashing that testers receive when they are on site.
They are rubber armoured, and have an integral solid lid to
cover the display.
Choose the PPK210 Part P kit to certify an installation to Part
P of the Building Regulations. The included MIT310 insulation
tester provides all required insulation test voltages, enabling
testing of SELV and PELV circuits at 250 V d.c. and standard
installation wiring at 500 V d.c.
The LRCD200 series is the latest generation of combined
non-tripping loop test and RCD test instruments. They
provide simple, affordable and flexible test tools for electrical
contractors testing energised circuits. The instruments are
supplied with a free Megger calibration certificate.
n
Safety interlock to prevent unsafe connection of the test
leads
n
PFC calculation and display
n phase safe – even when connected across phases, both you
3
and the tester will remain safe
M
IT320 insulation and continuity tester
Comprises the MIT320 insulation and continuity tester and
the LRCD220 Loop and RCD tester. PPK220 gives you all the
capability of the PPK210 and adds extra functionality.
n Buzzer disable
n ontinuity limit alarm
C
n nsulation limit alarm
I
n Frequency measurement
n Resistance measurement
n Backlit display
n Backlit ranges
n emote switch probe
R
Both LRCD210 and LRCD220
testers offer
LRCD220 Loop and RCD tester
Loop testing
n uto RCD testing
A
n 000 mA RCD test capability
1
n hase to Phase loop testing
P
n hase rotation display
P
PPK220
n Non-tripping 3 wire low current loop test provides
measurements from 0.01 Ω to 2 kΩ
n RCDs and RCBOs rated at 30 mA or less are not tripped when
loop impedance testing
n High current 2-wire fast loop test (LRDC220 only)
n 415 V Phase to phase loop measurement (LRCD220 only)
n Auto-ranging tests
n PFC button shows calculated PFC/PSCC result without re-testing
n Supply voltage displayed on connection to circuit
n Supply frequency measurement
n
Touch voltage limits and indication
PPK210 PPK220
Insulation testing
(see pages 10 and 11 for technical data) MIT310
n
MIT320
n
Loop and RCD testing
(see page 9 for technical data)
n
LRCD210
n
LRCD220
Megger calibration certificate
Full set of test leads
Instrument and document carry case
Batteries included
Warranty upgradeable to 3 years FREE
n
n
n
n
n
n
n
n
n
n
MFT
MFT
1700 Series
Combined loop and RCD testers
LRCD200 series
LRCD210 LRCD220
Loop test
Non tripping loop test
n
PFC calculation and display
n
Single phase testing
n
Phase to phase testing
High current loop test
3 phase safe
n
Voltmeter
n
RCD test
1⁄2 x I test
n
1 x I test
n
5 x I test
n
Touch / contact voltage display
n
Selectable 25/50 V touch voltage
n
10, 30,100, 300, 500 mA ranges
n
1000 mA
A, A selective, AC and AC selective
RCD tests
n
Automatic RCD testing
Selectable phase 0/180
n
Ramp test (20 % to 110 %)
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
General test
Frequency
n
Phase rotation
Backlight
n
n
n
Working voltage 230 V
n
Working voltage 110 V and 230 V
Free calibration certificate
n
Dust and weather proof to IP54
n
Warranty upgradeable to 3 years FREE
n
n
n
n
n
n
MFT
with
MFT with
certification
certification
Electrical
Electrical
test kits
test kits
Part P
kits P
Part
Combined
kits
loop and
RCD testers
Combined
loop RCD
testers
Insulation
testers
Industrial
insulation
testers
Loop
testers
RCD
testers
PATs
RCD testing
n 10 mA to 500 mA RCD testing, 1000 mA on LRCD220
n 1⁄2 I, 1 x I, 5 x I RCD test
n Tests Type A, A Selective, Type AC AC Selective
n 0°/180° selection
n Ramp testing
n 25 V or 50 V Touch voltage selection
n Optional Touch voltage display
Certification
software
Meter
test box
Voltage
detector,
Solar tester
For more information go to
bit.ly/PPK200
LRCD series accessories
Special features on
all testers
Accessories
Clamp and
multimeters
n Thick rubber armoured case
n Clear colour coded ranges
Earth testers
n Large easy to read displays
n uper grip test leads with lock on
S
croc clips
1001-883
3-wire in to 1 plug test lead set
1001-977
2-wire 10 A fused test lead set
Services
and leak
detectors
n Tough
n Easy to use
Cable fault
locator
n 3-phase safe
n Weatherproof
n Hands free testing
For more information go to
6220-740
UK mains test lead set
n Hard carry case
1001-976
2 wire test lead set
Network
performance
tester
bit.ly/LRCD200
Prices
8
PART P KITS
COMBINED LOOP AND RCD TESTERS 9
6. Insulation and continuity testers
MFT
MFT
1700 Series
Features
MFT
with
MFT with
certification
certification
MIT300 series
The Megger insulation testers are like no other tester you have used
The Megger insulation testers will take the bashing that
testers receive when they are on site
Your safety is Megger’s number one concern
They are rubber armoured and have an integral solid lid to protect the
display.
Electrical
Electrical
test kits
test kits
n
Safety interlock to prevent unsafe connection of the test leads
The heavy-duty hinge allows the lid to be locked away beneath when
in use, making it easy to use and impossible to lose.
And you don’t need to pull out the test leads to shut the lid.
These safety features look after you and the tester –
n
Safe contact detector keeping you and your tester safe during
continuity testing if it’s accidentally connected to a live circuit
Handy neck strap for hands free
operation
Clear range selector for poor light
conditions
Double hinge keeps screen free
from scratches or swings under
to snap out of sight
n
Live voltage warning alerts the user to a circuit voltage over 25 V
when insulation testing
The Megger MIT insulation testers are easy to use and quick
to learn
–
There are no buried functions, so it is easy to use these insulation
testers.
–
Prevents insulation testing when circuit voltage is greater
than 50 V
The colour coding helps test selection, speeding up testing time and
helping you identify faults fast.
Hands free operation
Combined
loop RCD
testers
n
Safety lockouts –
Shutter to prevent hazardous lead
combinations
Part P
kits P
Part
Combined
kits
loop and
RCD testers
The quick start guide in the lid keeps all the basic information at hand
if you need it.
How it works
Prevents continuity testing on live circuits
MIT300 series insulation testers are well balanced to hang
comfortably around your neck enabling hands free operation when
you need it.
The continuity test and buzzer start automatically when you connect
to a circuit, saving you time.
Insulation tests can be started using a switched probe or the test
button on the front of the tester.
The best place for a test button is on the probe.
By using a switched probe rather than a standard one there is
no longer a need to look away from the probe to find the TEST
button on the instrument, or use a third hand if both are already
holding the probes. Simply press the button already under your
finger.
Definitely safer and quicker.
Insulation testing
MIT300 MIT310 MIT320 MIT310A
MIT330
Analogue
250 V
n
n
n
n
n
500 V
n
n
n
n
n
1000 V
n
n
n
n
Test range
1000 MΩ
1000 MΩ
1000 MΩ
1000 MΩ
1000 MΩ
Insulation limit alarm 0.01 MΩ to 1000 MΩ
n n
Continuity testing
Continuity to 100 Ω
n
n
n
n
n
Continuity buzzer
n
n
n
n
n
Lead null to 9 Ω
n
n
n 1⁄2 Ω
n
Adjustable buzzer 1 to 100 Ω
n n
Audible buzzer disable
n n
Voltage measurement
Volts AC/DC
600 V
600 V
600 V
600 V
Resistance measurement 10 Ω to 1 MΩ range
n n
10 Ω to 2 KΩ range
n
Features
Voltage warning
n
Default voltmeter
n
n
n
n
Backlit display
n n
Backlit selector ranges
n n
Locking test button
n
n
n
n
n
Auto power-down
n
n
n n
Switched test probe
n n
Data storage
n
Download via USB port
n
IP54 weatherproof
n
n
n
n
n
Accepts rechargeable batteries
n
n
n
n
n
Included accessories
2 wire lead set
Free calibration certificate
Warranty upgradeable to 3 years FREE
n
n
n
n
n
n
n
n
n
n n
n
n
n
MIT series accessories
Industrial
insulation
testers
Loop
testers
RCD
testers
PATs
Certification
software
Meter
test box
Voltage
detector,
Solar tester
Accessories
MIT320 comes with switched probe
and calibration certificate
Clamp and
multimeters
Special features
n Thick rubber armoured case
1002-491
Red and black probes
and clips
n Clear colour coded selectors
Earth testers
1002-001
2 wire test lead set
n Large, easy to read display
Services
and leak
detectors
n
Super grip test-leads with lock on
croc clips
Tough lid prevents damage to
the display
n Auto-start continuity test
n Tough and easy to use
n Safe
1002-015
2-wire 500 mA fused test
lead set
n Weatherproof
1001-884
Remote switched probe
with special plug
n USB downloading on MIT330
Cable fault
locator
Network
performance
tester
For more information go to
bit.ly/MIT300
See page 12 and 13 for our industrial
insulation testers
10 INSULATION TESTERS
Insulation
testers
Prices
INSULATION TESTERS 11
7. Insulation and
continuity testers
MIT200 series
MIT220 and MIT230 are two of the
smallest insulation testers available
Both products have a combination of digital readout and
analogue display, using Megger’s patented DART display
technology. The display includes a clear, accurate digital readout, and an analogue pointer response for evaluating circuit
charge and discharge characteristics.
The tough ABS instrument housing is designed to withstand
the rigours of hard use, whilst small enough to drop into your
pocket when not in use. A low battery warning indicator gives
advanced warning of exhausted batteries.
for industrial maintenance and telecommunications
Continuity testing
n Automatic continuity testing is performed at 200 mA to
ensure compliance with international requirements. No need
to press the test button
n All instruments will measure up to 100 Ω on continuity, of
which 0-10 Ω is performed at greater than 200 mA
n Lead null is possible up to 9.99 Ω ensuring the ability to null
fused test leads as well as standard leads
n Voltage protection should you touch a live circuit
n Continuity buzzer provides a means of rapid cable testing
and circuit identification, with voltage protection should you
accidentally touch a live circuit
n The buzzer operates at a 5 Ω threshold
Insulation testing
n There is a choice of two or three test voltage ranges
providing an ideal solution to most low voltage insulation
testing applications
n Insulation measurement up to 1000 MΩ on all ranges
n Auto discharge ensures all circuits are safely discharged after
testing
n 1000 V insulation test ranges have a high voltage warning
prior to test voltage being applied
MFT
MFT
1700 Series
Insulation and continuity testers
MIT400 series
Continuity testing
Insulation testing
n 50 V to 1000 V insulation test voltages available with resistance
to 200 G Ω
n Unique 10 V to 100 V variable voltage tester (MIT40X)
n Test lock - Locks insulation test on
n Actual test voltage is displayed as well as insulation result
simultaneously
n Analogue arc replicates the response of a moving coil display
n Polarisation Index (PI), Dielectric Absorption Ratio (DAR) and
timer functions on most models
n Silicone leads prevent errors on high G Ω ranges
n Test inhibit prevents insulation testing if voltages in excess of 50
V or 75 V on telecoms testers are present. Live circuit detection
and protection
n Insulation buzzer - Preset the buzzer to an insulation
resistance limit from the setup menu
Special features
MFT
with
MFT with
certification
certification
n Auto test on contact enables real two handed operation
n A choice of 200 mA or 20 mA continuity test currents to increase
battery life
n Lead null - up to 9 Ω of resistance
n Buzzer - ON-OFF selected by simple push button
n Buzzer limit adjustable from 1 Ω to 20 Ω in 5 steps
Special features
Part P
kits P
Part
Combined
kits
loop and
RCD testers
Combined
loop RCD
testers
n CATIV 600 V
n TRMS voltage measurement
n I, DAR and timer measurement
P
and timer modes
n Remote switched probe
Insulation
testers
Industrial
insulation
testers
MIT400 series accessories
n Exceptional value for money
Electrical
Electrical
test kits
test kits
Loop
testers
n ocket sized tester
P
n ive circuit protected
L
RCD
testers
PATs
1002-001
2 wire test lead set
For more information go to
bit.ly/MIT200
1001-878
Switched CATIV 600 V probe
Certification
software
MIT220 MIT230
250 V and 500 V test ranges to 1000 MΩ
Meter
test box
n
250 V, 500 V and 1000 V test ranges to 1000 MΩ
n
Continuity (200 mA) measurement
n
n
Voltage detection
n
n
Intelligent safety system
n
n
Fast buzzer range
n
n
Display backlight
n
n
CATIII 600 V
n
n
IEC61010
n
n
n
n
Warranty upgradeable to 3 years FREE
1002-015
2-wire 500 mA fused
test lead set
Scan with your
smartphone to see
a demonstration
of the MIT400 series
or for more
information go to
1002-491
Red and black probes
and clips
bit.ly/MIT400
Industrial maintenance insulation
and continuity testers
Telecommunications insulation
and continuity testers
Voltage
detector,
Solar tester
Accessories
Clamp and
multimeters
MIT400 MIT410 MIT415 MIT420 MIT430 MIT40X MIT480 MIT481 MIT485
250 V, 500 V and 1000 V insulation test n
n n
n n
n
MIT200 series accessories
50 V and 100 V insulation test
n n
10 V , 25 V, 250 V and 500 V insulation test
n n
n
n
n
Earth testers
10 V to 100 V in 1 V steps
n
Resistance to
Continuity 0.01 to 200 Ω
Live circuit warning
20 GΩ
100 GΩ
50 GΩ
200 GΩ
200 GΩ
20 GΩ
100 GΩ
200 GΩ
200 GΩ
n
n
n
n
n
n
n
n
n
50 V
50 V
50 V
50 V
50 V
50 V
75 V
75 V
75 V
n
n
Polarization Index PI
n
n
n
n n
n
Frequency measurement
n
n
n
n n
n
Capacitance measurement
n
n n
n
Distance by capacitance
n
n
Data storage
n
1002-015
2-wire 500 mA fused
test lead set
n n
Dielectric absorption rate DAR
n
1002-001
2 wire test lead set
n
n
n n
Bluetooth downloading
n
n
CATIV 600 V
CATIV 600 V
CATIV 600 V
CATIV 600 V
CATIV 600 V
CATIV 600 V
CATIV 600 V
CATIV 600 V
CATIV 600 V
FREE calibration certificate
n
n
n
n
n
n
n
n
Safety
n
n
n
n
n
n
n
n
n
Cable fault
locator
Network
performance
tester
n
Warranty upgradeable to 3 years FREE
12 INSULATION AND CONTINUITY TESTERS
Services
and leak
detectors
INSULATION AND CONTINUITY TESTERS 13
Prices
8. 2-wire non-tripping loop testers
Three-phase safe
LTW series
The instruments will operate from 50 v phase to earth, up to
2 wire testing
440 v phase to phase.
The loop test is performed with only 2 test leads. This can be
either:
n Phase to Earth
n Phase to Neutral
n Phase to Phase (depending on model)
Testing is simple. There is no need for a third wire which could
cause confusion in identifying the part of the circuit under test.
High resolution test
Non-trip loop testing
LTW425 offers a high current, high resolution loop test to three
decimal places (0.001 Ω).
PFC Display
All instruments can calculate PFC and PSCC up to 20 kA and the
LTW425 can calculate up to 40 kA using the 0.001 high current,
resolution test range.
High current loop tester
LT300
MFT
MFT
1700 Series
Special features
MFT
with
MFT with
certification
certification
n High current loop testing
The LT300 offers high current loop testing over a wide range
of frequencies and supply voltages with simple, fast, two wire
operation.
n ide range of frequencies
W
Frequency range
n CATIV 300 V
Electrical
Electrical
test kits
test kits
n Wide range of supply voltages
Part P
kits P
Part
Combined
kits
loop and
RCD testers
Supply frequency is indicated upon connection and the LT300
will automatically set to the supply frequency either 16 Hz,
33 Hz, 50/60 Hz, 125 Hz or 400 Hz. Testing will commence
automatically.
Combined
loop RCD
testers
Loop measurement
LTW series testers do not trip working RCDs or RCBOs of 30 mA
or greater, using the non-trip loop test.
Two loop impedance ranges are provided.
20 Ω - Resolution to 0.01 Ω
200 Ω - Resolution to 0.1 Ω
Noise detection on non-trip tests
LTW uses sophisticated noise detection circuitry which
continually monitors the supply during a loop test to ensure the
accuracy of the result has not been affected by electrical noise
from plant and services.
Two operational modes are available:
a) erforms a 10 second test and if noise is detected a warning
P
is displayed.
b) Automatically extends a test to improve the accuracy.
Insulation
testers
Supply voltage
Operational supply range extends from 50 V to 550 V
(400 V @ 16 Hz), with a warning for voltages over 330 V
highlighting accidental phase to phase connections on a
nominal 230 V system.
Industrial
insulation
testers
Loop
testers
LT300 series accessories
High current loop testing
For supplies that are not RCD protected the high current test
can be used, as there is no risk of tripping the RCD.
RCD
testers
The popular LTW325 comes
complete, ready for work
Auto start
An auto-start function will start the test as soon as the circuit
voltage is detected, removing the need of a third hand and
allowing for much faster testing.
PATs
Special features
1001-976
2 wire test lead set
n Uses only two wires to loop test
6220-810
UK mains test lead set
Certification
software
1001-977 2-wire 10 A
fused test lead set
For more information go to
n Will not trip RCDs while loop
testing
n Will not take out 6 A MCBs
n Clear easy to read display
n 3-phase safe
n 50 V to 480 V operation
n PFC display
n Stable test results
n USB downloading on LTW335
n Max Z facility, not on LTW315
n alculated R1 + R2, not on
C
LTW315
bit.ly/Megger_LT300
Loop testing
Features
LTW315 LTW325 LTW335 LTW425 LT300
2-wire non-tripping loop testing
n
n
n
n
2-wire high current, fast, loop testing
n
n
n
n
110 V to 280 V applications
n
n
n
50 V to 440 V applications
n
n
n
n
50 V to 550 V applications
Phase to phase testing
n
n
n
PFC range 20 kA
n
n
n
n
PFC range 40 kA
n
Resolution 0.01 ohm
n
n
n
n
Resolution 0.001 ohm
n
Automatic noise detection
n
n
n
n
Automatic test start
n
n
n
n
Frequency measurement
n
n
n
n
16 Hz to 400 Hz operation
Max Zs display
n
n
n
Calculated R1 + R2 display
n
n
n
n
n
n
n
n
n
14 LOOP TESTERS
n
n
n
Back lit display
n
n
Built-in fold away cover
n
n
Quick start guide in cover
n
n
Test result storage
Downloading of test results
Accepts rechargeable batteries
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
Storage and carry case
2-wire lead set complete with crock clips
Mains socket lead set
Free calibration certificate
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
Optional
Optional
Standards
IEC61010-1 CATIV 300 V
EN61557
Weather- and dust-proof to IP54
Warranty upgradeable to 3 years FREE
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
Accessories
Clamp and
multimeters
Included accessories
bit.ly/LTW_series
Voltage
detector,
Solar tester
n
For more information go to
Meter
test box
Earth testers
Services
and leak
detectors
Cable fault
locator
Network
performance
tester
Prices
LOOP TESTERS 15
9. RCD testers
RCDT300 series
Special features
The Megger RCD testers provide the
full solution to RCD testing
MFT
MFT
1700 Series
n Clear LED polarity indicator
The RCDT tests not only Type A and Type AC RCDs, but also the
selective (time-delayed) variants of both types, performing 1⁄2I,
1I and 5I tests on RCDs rated at 30 mA, 100 mA, 300 mA and
500 mA tested at 0° or 180°.
The RCDT320 offers additional tests for RCDs rated at 10 mA
and 1000 mA.
Touch voltage is measured at the start of a test, and will
automatically inhibit if it exceeds the preset level.
Touch voltage inhibit is selectable from 25 V to 50 V.
Save your valuable time
RCDT320 offers additional time saving features.
Auto RCD testing – RCDT320 will automatically cycle through
the 1⁄2I, 1I and 5I tests at 0° or 180° recording the results, so you
can stay with and reset the RCD. This means the job gets done
faster, saving not only your time but your legs as well!
Ramp testing to measure the trip current of an RCD – the test
current is slowly increased from 1⁄2I to 1I+10%. The trip current
is held on the display, making it quicker and easier to diagnose
nuisance tripping.
RCDs on 110 V (55 V - 0 - 55 V) centre tapped site supplies can
be tested by the Megger RCDT320 due to its wide operating
voltage range of 50 V to 280 V.
Features
MFT
with
MFT with
certification
certification
n Thick rubber armoured case
Electrical
Electrical
test kits
test kits
n Large, easy to read display
n uper grip test-leads with lock
S
on croc clips
Shutter mechanism makes it easy
to use the right leads
n Tough
n Easy to use
Heavy duty hinge locks away
underneath
n Safe
Clear range selector for poor light
conditions
n Weatherproof to IP54
Clear LED polarity indicators help
you get the right wiring and test
lead connection
Combined
loop RCD
testers
n Hands free auto-RCD testing
n USB downloading on RCDT330
Your safety is Megger’s number one concern
These RCD testers have built in safety features to look after you
and the tester –
n
Safety interlock to prevent unsafe connection of the test
leads
n
Test inhibit, if the supply voltage exceeds 280 V
n phase safe – even when connected across phases, both you
3
and the tester will remain safe
n
LED connection indicators display correct test lead
connection, making sure it is right first time
Megger RCD testers will take the bashing that testers receive
when they are on site
They are rubber armoured and have an integral solid lid to
cover the display.
The lid has a heavy-duty hinge that locks away underneath
when in use, making it easy to use and impossible to lose.
And you don’t need to pull out the test leads to shut the lid.
Part P
kits P
Part
Combined
kits
loop and
RCD testers
Insulation
testers
How it works
Use the ‘ramp test’ to identify nuisance tripping RCDs.
An overly current sensitive or faulty RCD can cause
nuisance tripping of the RCD, which can be very difficult
to locate. A current clamp meter is not fast enough.
By testing with a ramp test, the test current is slowly
increased until the RCD trips. The tester displays the trip
current in milliamps (not the trip time). If this is too low,
replace the RCD.
Industrial
insulation
testers
Loop
testers
RCD
testers
PATs
Megger RCD testers are so easy to use and quick to learn
n
There are no buried functions, so they are easy to use
n
The colour coding helps test selection, speeding up testing
time and helping you identify faults fast
n
The quick start guide in the lid keeps all the basic
information at hand when you need it
Certification
software
Meter
test box
RCDT300 series accessories
1001-976
2 wire test lead set
6220-740
UK mains test lead
bit.ly/RCDT300
16 RCD TESTERS
1001-977 2-wire 10 A
fused test lead set
RCD testing
1
⁄2I, 1I, 5I RCD trip time test
n
n
Selective breakers
n
n
Type A and AC breakers (1⁄2I, 1I, 5I)
n
n
Programmable RCD
30, 100, 300, 500 mA RCDs
n
n
10, 1000 mA RCDs
n
RCD trip current test (RAMP)
n
Auto RCD test
n
0°/180° polarity selection
n
n
Touch voltage selectable
n
n
Max touch voltage (25 V/50 V)
n
n
Operating range 100 to 280 V
n
Operating range 50 to 280 V
n
n
n
n
n
n
n
n
n
n
n
n
Features
3-Phase safe
n
n
Large clear display
n
n
Backlight
n
Battery status indication
n
n
Auto power down
n
n
Fuse blown indication
n
n
Data storage
Download via USB port
IP54 weatherproof
n
n
IEC61010-1 CATIII 300 V
n
n
EN61557
n
n
n
n
n
n
n
n
n
n
n
n
n
Accessories included
RCDT testers come complete
with calibration certificate in a
tough carry case
For more information go to
1002-490
Red, blue and green
probes and clips
RCDT310 RCDT320 RCDT330
UK mains test lead
n
2 wire test lead with probes and clips
Warranty upgradeable to 3 years FREE
n
Free calibration certificate
n
n
n
n
n
n
n
n
n
n
RCD TESTERS 17
Voltage
detector,
Solar tester
Accessories
Clamp and
multimeters
Earth testers
Services
and leak
detectors
Cable fault
locator
Network
performance
tester
Prices
10. Portable Appliance
Testers
PAT300 series
A choice of two fast PAT testers which offer the operator
manual and automatic operation without the complexity
of data storage. The PAT300 series allows the user to select
a range of tests, such as those for a CLASS I asset, simply by
pressing the “CLASS I“ button, and then initiate the test by
pressing the “TEST” button. When the results are displayed
they are coded green for a pass and red for a fail. However, if
a particular test needs to be repeated, there are direct access
buttons dedicated to specific tests. The instant-restart feature
speeds testing when moving from one room to another, restarting in exactly the same menu location where it was left.
PAT320 is the PAT tester for those electricians who occasionally
do testing and don’t want the complexity of database
management and are happy to write out certificates by hand.
n Instant re-start
n 200 mA “soft” bond test and the option of high current 25
A and 10 A bond tests
n Test lead null
n Flash testing at a choice of 1.5 kV or 3 kV (PAT350 only)
n Repeated high current bond testing possible
n Insulation testing at 250 V and 500 V
n Fully tests 230 V and 110 V appliances
n Extension and IEC lead testing, including polarity, earth
continuity, L-N continuity and L-N-E insulation
n Standard differential leakage test
n Protective conductor or touch current
leakage test
n Substitute earth leakage test at
40 V a.c.
n Full plug-in 30 mA RCD testing
½ x I, I, 5 x I
n Integral fuse checker
Of particular interest to tool hire companies, as well as service
and repair organisations, is the PAT300 series ability to run high
current bond tests virtually continuously, without the fear of
the tester over heating.
Because the PAT testing market is driven by the “Electricity
at Work” regulations and not by the economy, there is an
excellent opportunity to boost your turnover by introducing a
PAT testing and repair service.
To make it easier for you to change direction, Megger has
introduced the “Business in a box”. This is a new concept
in electrical test products, not just selling you the tester but
helping you find business.
Many customers have found these pre-packed businesses useful
in making money again in the teeth of the recession.
There are two potential businesses in a box, the PAT320 manual
version, and the PAT420 computerised version.
In the box you will find everything you need to diversify the
direction of your business and boost your income.
1. Tough PAT tester that will give you years of service
PAT350 is similar to the PAT320 but with the added benefit of
flash testing. Because of its high through-put capabilities and
the speed at which it gives results, it is ideal for applications
such as tool hire companies and service centres.
MFT
MFT
1700 Series
Business in a box
Why diversify your
business into PAT Testing?
2. Leads and adaptors you need to do the job successfully
3.1
The PAT320 comes with duplicate test report book for
users to certify results and issue to their customer
Scan with your smartphone to see a
presentation of the PAT business in the
box or for more information go to
Special features
bit.ly/PAT320_BIAB
bit.ly/PAT420_BIAB
MFT
with
MFT with
certification
certification
Electrical
Electrical
test kits
test kits
3.2
The PAT420 come with PowerSuite Contractor PAT
certification software to manage:
Customers
n Arrange appointments
Assets
n Automatic testing
n
Diary management
n
Printing certificates
n
Billing
n
Repairs estimates
5. guide to PAT testing – clear step by step instructions on
A
how to do it
6. guide to identifying customers and selling to them.
A
This includes
n
Where to find and how to approach clients
n
Details of who, and why they need to be testing their
electrical assets
n
G
uidelines on what to charge
n
n
P
re-written press releases for you to generate interest
n
P
re-written letters for you to send to your potential
customers
bit.ly/PAT300
Insulation
testers
Industrial
insulation
testers
Pre-designed advert and brochure for you to customise
Earth bond test
25 A
n
n
n
n
n utomatic or manual testing
A
10 A
n
n
n
200 mA
n
n
n
Insulation test
500 V
n
n
n
n
250 V
n
n
n
n
Earth leakage test
Differential
n
n
n
Touch current
n
n
n
n
Substitute
n
n
n
n
Operation test
110 V
n
n
n
n
230 V
n
PATs
n
RCD
testers
n
n Continuous operation
Loop
testers
n
Scan with your smartphone to see a
demonstration of the PAT300 series
or for more information go to
Combined
loop RCD
testers
4. Roll of 1000 pass labels
PAT320 PAT350 PAT320 PAT420
in a box
Business in a box Business in a box
n ull PAT functionality with the
F
option of flash test
Part P
kits P
Part
Combined
kits
loop and
RCD testers
n
n plug-in or lead mounted
Full
RCD testing
n Simple push button control
Class I
n
n
n
n
Class II
n
n
n
n
Extension test lead
n
n
n
n
Portable RCD
n
n
n
n
Fuse test
n
n
n
n
Test lead null
n
n
n
n
Operates at
110 V
n
n
n
n
230 V
n
n
n
n
Functional test VA measurement
110 V
n
n
n
n
230 V
n
n
n
n
Test sockets
BS1362
n
n
n
n
BS4343
n
n
n
n
On-board client/locations results database
n
Download to USB memory stick
n
Display
PATR210 Portable appliance
test report book
Colour 1⁄8 VGA
Colour 1⁄4 VGA
n
n
1001-227
Fail label
roll of
1000
n
Combined continuity, earth bond and insulation test lead
n
n
n
n
230 V extension lead adaptor
n
n
n
n
FREE calibration certificate
n
n
n
Accessories
Clamp and
multimeters
Earth testers
n
n
Pass labels
n
n
n
Services
and leak
detectors
n
PC power supply to IEC adaptor
1000-767
415 V 4 pin
adaptor lead
to BS1363
Voltage
detector,
Solar tester
n
Portable appliance test report book
1000-971
Pass label
roll of
1000
Meter
test box
n
1000-766
110 V
mains lead
adaptor
n
Automatic tests sequence
Accessories
n
Flash
Certification
software
PowerSuite Professional Contractor PAT certification software with client and
asset management and billing
n
Megger guide to PAT testing
n
n
Megger guide to marketing a PAT business
n
Cable fault
locator
n
Barcode reader
optional
Barcode printer
Network
performance
tester
optional
Prices
18 PORTABLE APPLIANCE TESTERS
PORTABLE APPLIANCE TESTERS 19
11. Portable Appliance
Testers
PAT 400 series
n
Three PAT testers with full database functionality based on the
well received PAT300 series. The PAT 400 series introduces a
new level of convenience and speed to PAT testing using onboard test results storage.
n
With a large, bright and intuitive colour display, the PAT400
series offer sufficient memory for the storage of up to 10,000
assets. The proven long duty cycle, the simplicity of operation
and the independently verified speed of test make for the best
selling PAT Megger has ever produced.
n
The menus have been simplified to make operation quicker.
Five soft-keys give direct access to frequently used functions
making navigation through the menus quick and the tester
more productive, offering a greater return on investment. A
new feature is the expert and novice modes making testing
even faster for experienced user.
n
n
n
n
n
n
n
n
n
10,000 asset on-board data storage
Large easy to ready colour screen
Instant re-start
25 A, 10 A and 200 mA “soft” bond test
Test lead null
Repeated high current bond testing possible
Insulation testing at 250 V and 500 V
Functional VA load test for 110 V and 230 V appliances
Extension and IEC lead testing including polarity, earth
continuity, L-N continuity and L-N-E insulation
Standard differential leakage test plus
n Protective conductor or touch current leakage test
n Substitute earth leakage test at 40 V a.c.
Simple RCD test or full 30 mA RCD testing ½ x I, I, 5 x I
Integral fuse checker
MFT
MFT
1700 Series
PAT400 series accessories
MFT
with
MFT with
certification
certification
Electrical
Electrical
test kits
test kits
1001-047
Barcode scanner
1000-770 415 V 5 pin adaptor
lead to BS1363 (16 A)
1001-046 Pass / fail
barcode printer
Combined
loop RCD
testers
1000-971
Pass label
roll of 1000
1000-766 110 V
mains lead adaptor
For corporate users, the PAT400 series now has an optional
security log-in for controlling access to test parameters and
limits, while logging the active user within the results database.
1000-767 415 V 4 pin adaptor
lead to BS1363
1001-227 Fail
label roll of 1000
6220-639 110 V
extension lead adaptor
Using a standard USB memory stick, results can be quickly
backed up for downloading. The asset database is accessible
from the tester and with a full QWERTY keyboard, rapid data
entry or adjustment is possible.
PAT410 PAT420 PAT450
PAT410 is perfect for those happy to bond test solely at
200 mA. The smallest and lightest of the PAT400 series weighs
only 2.7 kg.
Supply
230 V
n
110 V
Supply measurement
n
n
n
n
PAT420 tests both 100 V and 230 V appliances, as well as
offering bond testing at all three test currents, 200 mA, 10 A
and 25 A. This is the tester of choice for full-time industrial or
commercial PAT testers.
Earth bond/continuity
200 mA
n
10 A
25 A
Bond lead null
n
n
n
n
n
n
n
n
n
PAT450 adds in the ability to carry out high voltage flash
testing at 1.5 kV or 3.0 kV, making it the preferred choice for
tool hire companies and service and repair workshops.
Insulation test
250 V
500 V
n
n
n
n
n
n
Alternative leakage tests
Substitute
Differential
Touch current
n
n
n
n
n
n
n
n
n
Functional test
VA measurement
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
Special features
n xpert mode to speed up
E
testing
n ecure user log-in option
S
n ast on-board memory to keep
V
you on the job longer
n ontinuous operation, no need
C
to stop and wait for the tester
to cool down
n
I
nstant re-start as you move
from room to room
n oft keys to speed you through
S
the testing process
n utomatic asset number
A
generation
n uick test for instant access to
Q
single test functions
20 PORTABLE APPLIANCE TESTERS
Industrial
insulation
testers
Loop
testers
PATs
Extension lead tests
Earth bond
Insulation
Polarity
Portable RCD tests
Flash test
1.5 kV and 3.0 kV
n
Other features
Low-profile light weight
n
110 V test connection
n
Auto test routine
n
n
Manual testing
n
n
Configurable tests times
n
n
Selectable pass limits
n
n
Fuse check
n
n
Large colour display
n
n
n
n
n
n
n
n
n
Data handling
10,000 record on-board storage
Download to USB memory stick
PowerSuite compatible
n
n
n
Supplied accessories
Scan with your smartphone
to see a demonstration of
the PAT400 series or for
more information go to
n
n
n
n
n
n
Certification
software
bit.ly/Megger_PAT400
Meter
test box
For PAT420
Business in a box
see page 19
Voltage
detector,
Solar tester
Accessories
*Testing conducted by
Redford Charles Ltd, Rochester,
see details at
www.redfordcharles.com/resources/
PAT_tester_analysis.pdf”
Carry case with lead storage pouch
n
n
n
Combined continuity, earth bond and
insulation test lead
n
n
n
Red extension lead adaptor
n
n
n
Flash test lead
n
FREE calibration certificate
n
n
n
Insulation
testers
RCD
testers
n
n
n
I
ndependent tests* show the Megger
PAT400 is at least 8% more productive
Part P
kits P
Part
Combined
kits
loop and
RCD testers
Clamp and
multimeters
Earth testers
See how to PAT test
the Megger way
with PAT testing and
inspection DVD
order no 1002-384
Services
and leak
detectors
Cable fault
locator
Network
performance
tester
Prices
PORTABLE APPLIANCE TESTERS 21
12. Test certification software
PowerSuite Professional
Meter test box
MTB7671/2
Works with all makes of testers
actively measuring the output of the
meter and confirming it is within the
limits prescribed as well as checking
the readings
Developed over many years and with lots of research into
your requirements of a software system, PowerSuite is hugely
flexible. The application you purchase today can readily be
up-graded, so even misjudging how much you will come to rely
on computerisation for your certification is not a risk. As your
company grows, so can your system.
PowerSuite Lite package is the ideal starting point for a
company using computerised certification. With minimal
complication and maximum impact. The benefits can be
experienced for little cost.
Certification bodies like the NICEIC, ELECSA, NAPIT, ECA
and others now request evidence of your tester’s accuracy
and consistency.
The MTB7671 makes that an easy job.
n
Tests
n
Does
the full range of a tester’s capability
not trip RCD protected circuits
n ests
T
to the regulations BS7671, BS EN61557 and IEE On-Site
Guide
n hecks
C
n
Confirms
n
Colour
Continuity short circuit test current
PowerSuite Contractor package will give you everything you
need to schedule and invoice electrical inspection and PAT
testing certification.
PowerSuite Power package gives added breadth to your
certification client base by offering more specialised electrical
inspection certificates, such as filling stations and security, and
for general maintenance by adding ladder, air compressor, fire
extinguisher and many other certificates.
BS7671, BS EN61557 and
IEE On-Site Guide
tester requirements
200 mA
insulation, continuity, loop, PFC and RCD functions
tester’s continued performance
coded test functions
200 mA
4 V - 24 V
4 V – 24 V
0.5 Ω
5.0 Ω
PowerSuite SME is the networking solution for those with a
business of sufficient size to need multiple simultaneous access
to the client and certificate database. It is fully flexible with
four levels of security, messaging, data entry options, multiconcurrent user access, etc.
Insulation test current
1 mA
Our market leading help-desk is already looking forward to
assisting you. We are there to help you select the version of
PowerSuite that is ideal for your business. Call today on
01304 502 106.
Pass / fail Indication
Insulation test resistances
0.25 MΩ min
0.25 MΩ
0.5 MΩ min
0.5 MΩ
1 MΩ min
Part P
kits P
Part
Combined
kits
loop and
RCD testers
Pass / fail indication
Continuity resistance
Electrical
Electrical
test kits
test kits
Insulation
testers
Pass / fail indication
Continuity test voltage range
MFT
with
MFT with
certification
certification
Combined
loop RCD
testers
MTB7671
parameters tested
MFT
MFT
1700 Series
1 MΩ
1 mA
250 V +25% max
250 V +25% max
500 V +25% max
500 V +25% max
For more information go to
Pass / fail indication
Insulation test voltages
1 kV +25% max
1k V +25% max
Lite
Lite
Contractor
On-site
Contractor On-site
Ultra
Power
SME
Certificate manager including IET, NICEIC, ECA, Select, ELECSA
n
n
n
n
n
Certificate audit trail
n
n
n
n
n
n
Client manager
n
n
n
n
n
n
Wizard and menu functions
n
n
n
n
n
n
Company logo import
n
n
n
n
n
n
Document storage including Word, Excel, pdf and many more
n
n
n
n
n
Photo import
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
Additional certificates
n
n
n
n
Maintenance certificates
n
n
Document design
n
n
Viewer CD
n
Certification
software
10.3.5 Earth Electrode Resistance)
n
Billing
Loop + 180 Ω
PATs
(IEE On-Site Guide
n
Reports
Loop + 180 Ω 200 Ω max
n
Identify missing assets
Loop + 10 Ω
n
Organiser n
mobile
n
Local mains impedance
Loop + 10 Ω
RCD
testers
90 MΩ
Loop
Loop
testers
9 MΩ
bit.ly/PowerSuite
Industrial
insulation
testers
n
Image management
Networkable with multi-user access
n
n
n
n
n
n
n
n
n
n
n
n
n
1999 mS
200 mS
40 mS @ 0°
Meter
test box
50 mS @180°
RCD (5 x I)
10 mS @ 0°
40 mS
20 mS @ 180°
Voltage
detector,
Solar tester
How it works
Accessories
Checking your testers on a regular basis is vital. You can
spot a problem before it happens, making sure your meter
is ready for use when you want it. But it is important
that you check what the tester is putting out. If the test
voltage or current is low it doesn’t stress the system
you’re testing properly so you’re not testing to the Wiring
Regulations.
Clamp and
multimeters
n
3rd party instrument support
No trip
RCD (I)
n
Megger 17th data down load
RCD no trip (1⁄2I)
n
Megger PAT data down and up load
10 mA, 30 mA and 100 mA
n
Multiple data paths
RCD currents (I)
n
Earth testers
Real-time Bluetooth results capture
n
n
n
n
n
n
Enabled for PowerSuite Ultramobile
n
n
n
n
n
n
Drag and drop editing
n
n
n
n
n
n
n
Manual data entry
n
n
n
n
n
n
n
Direct data entry
n
n
n
n
n
n
n
n
PDA installation
n n n
E-mails certificates between mobile device and
PowerSuite Professional
n n
n
Additional user licences
n
bit.ly/MTB7671-2
n n n
Imports, exports to PowerSuite Professional
For more information go to
n n n
Smartphone installation
Services
and leak
detectors
n
n
n
30 days
30 days
30 days
30 days
Network
performance
tester
n n
Additional network licences
FREE support
Cable fault
locator
30 days
n
30 days
* PowerSuite Ultramobile can only be used in conjunction with one of the other PowerSuite Professional products and is included in the On-site packages.
22 TEST CERTIFICATION SOFTWARE
Prices
METER TEST BOX 23
13. Photovoltaic kits
PVK300 series
Volt finder and flashlight
VF series AC voltage
detector
PVK300 kits supply all the instrumentation you require – in
addition to your MFT – to site, commission and test a solar PV
installation to IEC62446, packed in a single pouch.
VF2 Voltage finder has a
helpful audible warning
PVK320 includes an auto-ranging, CAT IV, 10 A d.c. AVO410
multimeter that allows the short circuit current of a panel to be
read directly, as well as the PVM210
PVK330 includes the DCM340 a 600 A a.c./d.c clamp multimeter
which speeds the measurement of array stings without the
need for disconnection. It can also measure d.c. voltages to
600 V.
VF1 and VF2 Volt finder and flashlight
Low power consumption – many hours of flashlight
illumination from one set of alkaline batteries.
Identifying live conductors, finding a break in a wire, verifying
a blown fuse while in circuit, and detecting the presence of a.c.
voltage.
For more information go to
bit.ly/VF1_VF2
PVK320 PVK330
AVO410 CAT IV multimeter
n
DCM340 Clamp multimeter
n
PVM210 Irradiance meter
n
n
MC3 to MC4 adaptor testleads
n
n
MC4 to 4 mm plug testleads
n
n
For more information go to
bit.ly/PVK300
For more information go to
The easy-to-use
TPT210 will warn of a
voltage present even
with flat batteries
PATs
bit.ly/PVM210
n
Single
unit for one handed use increasing safety on ladders
and roofs
n
Perfect
for measurement of incident light for PV panel short
circuit current calculation
n
1999
W/m2 range on 33⁄4 digit LCD display
n
Camera
mount fixing for accurate placement
The pocket-size PVM210 is perfect for use on sloping roofs or
at the top of ladders because it has the solar detector built in
to the top. This is enhanced by its large clear display and hold
function.
It is used for initially choosing optimum position for a PV
installation and for measuring the solar power for the
calculation of short circuit current to confirm the performance
of the PV panel for certification.
On the rear of the meter is a universal camera thread that
allows mounting for precise readings if required, also a
protective pouch is included with each instrument.
24 VOLTAGE DETECTOR, SOLAR TESTER
Voltage
TPT210
TPT220
6 to 1000 V a.c./d.c. in 8 steps
6 to 1000 V a.c./d.c 1 V resolution
Continuity
Up to 500 KΩ visual and audible
Resistance
100 V a.c.
Dual coloured LEDs
LCD with auto backlight
Torch
For more information go to
n
n
IP65 protection
n
n
Up to 150 Ω audible buzzer
0 – 2000 Ω
n
CAT IV 1000 V
CAT IV 1000 V
Warranty upgradeable to 3 years FREE
n
n
Clamp and
multimeters
Good practice demands that a two-pole tester is proved on a
known live source or proving unit both before and after use.
The Megger MPU690 is a convenient method to prove the safe
operation of all two-pole testers and Drummond test lamps.
n
n
n
n
Capable of testing two-pole voltage detectors and test
lamps due to 10 W output
Step voltage LEDs indicate voltage being generated. 50 V,
100 V, 230 V, 400 V and 690 V
Generates a.c. waveform for a true test
Compact design that has an integral magnet for attaching
to the cabinet encourages routine safety checks
Automatic on and off conserves batteries
Low battery indication gives ample warning to replace
batteries
Warranty upgradeable to 3 years FREE
Voltage
detector,
Solar tester
Accessories
Proving unit
MPU690
n
Meter
test box
n
Safety rating
n
Certification
software
100 V a.c.
Manual RCD trip
n
Combined
loop RCD
testers
RCD
testers
Display
Solar PV testing
Irradiance meter
PVM210
Part P
kits P
Part
Combined
kits
loop and
RCD testers
Loop
testers
Phase indication
bit.ly/TPT200
Electrical
Electrical
test kits
test kits
Industrial
insulation
testers
Guaranteed not to trip an RCD, the TPT210 is a 2-pole tester
which indicates the presence of voltage with an array of LEDs,
while the TPT220 uses an LCD display. Both offer additional
functions such as voltage display, phase rotation determination
without the need to cross probes, continuity and RCD trip test.
Safety is paramount with these testers, so they are rated at
CAT IV 1000 V, are supplied with GS38 shrouds and the tough
body is rated to IP65. It goes almost without saying that they
continue to indicate live systems even when the battery is
removed.
MFT
with
MFT with
certification
certification
Insulation
testers
Voltage testers
TPT200 series
MFT
MFT
1700 Series
Earth testers
Services
and leak
detectors
Cable fault
locator
Network
performance
tester
For more information go to
bit.ly/MPU690
VOLTAGE DETECTOR, SOLAR TESTER 25
Prices
14. Socket interface adaptor
SIA10
MFT
MFT
1700 Series
Socket tester
MST210
Sometimes known as a breakout lead, the SIA10 allows sockets
to be tested without disassembly.
n revents damage to connections
P
n Reduces test time
n Decoration remains intact
n olour coded for simplicity of use
C
n akes testing easy where access to socket is limited
M
n emains safe if left inadvertently connected to live supply
R
MFT
with
MFT with
certification
certification
n
Simple
and effective identification of faulty wiring at
sockets
n Easy to use
n green and 1 red LED for instant error reporting and fault
2
diagnosis
n
Identifies 17 missing wire and wrong connection
combinations
n Tough and reliable
Electrical
Electrical
test kits
test kits
Part P
kits P
Part
Combined
kits
loop and
RCD testers
Combined
loop RCD
testers
For more information go to
Insulation
testers
bit.ly/ Megger_SIA10
Industrial
insulation
testers
PAT and 17th Edition
inspection DVDs
n
Instructional DVDs on testing and inspecting installations
Ideal study aids for anyone enrolled on a CG2394,
CG2395 or equivalent course
n Excellent refresher on best practice for experienced
electricians
n
Phase Sequence Indicator
PSI410
Order number
DVDs
Electrical work on commercial and industrial installations often
requires working on motorised machinery with three phase
supplies. Correct sequence of the phases is important with
certain motors and pumps as damage to brakes and valves will
occur in minutes with incorrect phasing.
Initial inspection and test of a domestic property
The PSI410 is self powered from the supply and requires no
batteries.
n
LED
For more information go to
bit.ly/PSI410
26 ACCESSORIES
clockwise and counter clockwise phase rotation
indication
n
Audible indication of direction
n Phase condition LEDs
n Fused test leads
n
Dual phase colour identification
n
CAT IV 600 V
n
Warranty upgradeable to 3 years FREE
PATs
DVD200
PAT testing and inspection
1002-384
Certification
software
For more information go to
bit.ly/Megger_DVDs
Meter
test box
Voltage
detector,
Solar tester
The unit has been designed to provide a slow rotational speed
of the display to allow easy recognition of the direction of
rotation.
The PSI410 also features a triple bi-coloured LED display
that indicates that all three phases are present. A green LED
indicates the phase is present while a red LED shows a missing
phase connection. The unit has a tough case designed for an
industrial environment and is supplied with long fused test
leads with croc-clips and prods.
RCD
testers
DVD100
Initial inspection and test of industrial properties
The Megger PSI410 phase rotation indicator provides rapid
indication of correct phase sequence utilising a three bicoloured LED display and a specific audible tone. Clockwise
rotation is indicated by clockwise rotating green LEDs with a
continuous tone and counter clockwise rotation has counter
clockwise rotating red LEDs and a warbling tone.
Dual phase colour coding has been adopted for the PSI410 to
allow ease of use on both Brown / Black / Grey and Red / Yellow
/ Blue colour coded supplies.
Loop
testers
Accessories
Extension
test lead and coil
Clamp and
multimeters
n
30
metre and 50 metre versions
for direct R2 measurements
n
Easy to re-wind cable with tangle-free cable guide
n Compact and light design
n
Suitable
Earth testers
Services
and leak
detectors
Compact extension test lead for direct R2 measurements so
eliminating the need for crossover connections. The furthest
point in the circuit can be easily verified, and every earth point
on the circuit checked for integrity prior to energising.
Cable fault
locator
Code
50 m extension lead, green, with 4 mm safety plug
ETL50
30 m extension lead, green, with 4 mm safety plug
ETL30
Network
performance
tester
For more information go to
bit.ly/ETL30_ETL50
Prices
ACCESSORIES 27
15. Clamps and multimeters
400 A a.c. clampmeter
DCM310
Classic multimeter
AVO300
series
Easy to read
n Manual operation
n Low cost
n Tough
This easy to use clampmeter is
ideal to rapidly check the current
flowing with the minimum of
fuss.
AVO410
n
Voltage,
current and resistance measurement
rms on a.c. functions
n uto ranging but with the option of manual
A
range selection
n ax and min measurements
M
n ata hold
D
n
Continuity and diode testing
n μF capacitance and 60 MHz
600
frequency ranges
n
Tough rubber holster
n
CAT IV 600 V safety
n
True
Straight forward and tough
multimeter
n uto-ranging function
A
n
Separate fuse and battery
compartment, allows both
to be replaced without
breaking the calibration
seals
n
Rubber-armoured case
has an integral stand and
hanger
n
Large uncluttered display
n VO310 has a backlight
A
n
CAT III 600 V safety
MFT
with
MFT with
certification
certification
DCM320
n
CAT IV multimeter
MFT
MFT
1700 Series
400 A a.c.
Clamp multimeter
n
20 MΩ resistance range
Continuity buzzer
n Auto-ranging
n
Auto off to conserve
batteries
Electrical
Electrical
test kits
test kits
n
Part P
kits P
Part
Combined
kits
loop and
RCD testers
The DCM320 is a low cost
data hold current clamp and
multimeter. It is supplied
blister packed complete with
test leads, batteries and
carry case.
For more information go to
bit.ly/DCM310_DCM320
Combined
loop RCD
testers
Insulation
testers
DCM310
For more information go to
DCM320
bit.ly/AVO410
Fork multimeter
DCM330
bit.ly/AVO300
n
200 A a.c. Open-Jaw current
measurement
n 0.1 V to 1000 V auto-ranging a.c. and
d.c. voltage measurement
n 0.1 Ω to 20.00 MΩ Resistance range
n Continuity buzzer and diode check
n Non-contact detection of a.c. voltage
n CATIV 600 V
The Megger DCM330 is suitable for use
anywhere where there is a requirement to
measure a.c. current in single unshielded
conductors less than 16mm diameter, a.c./
d.c. voltages up to 1000 V, or resistances
up to 20 MΩ.
Earth leakage clampmeter
DCM300E
Versatile high resolution a.c. current clamp, ideal for
checking nuisance tripping RCDs
n 4 ranges: 30 mA range (0.01 mA resolution),
300 mA, 30 A and 300 A
n 31⁄2 digit LCD with analogue bar graph
n Data hold
DCM340
n
Powerful range of tough
multimeters
For more information go to
600 A a.c. / d.c.
Clamp multimeter
n
Multimeters series
accessories
DCM300E is perfect for measuring earth leakage current in a
circuit where the RCD repeatedly trips out. The measured result
will quickly identify whether the tripping is caused by excessive
leakage current, or if the RCD itself is faulty. With its high noise
rejection, it can measure leakage differentials, when clamped
around the live and neutral of a circuit simultaneously.
For more information go to
DCM330
n
n
n
n
d.c. current range
Frequency counter
Analogue bar graph
Back light
Large jaws
Auto off to conserve batteries
PATs
Certification
software
Meter
test box
For more information go to
Voltage
detector,
Solar tester
bit.ly/DCM340
DCM340
1002-001
Replacement test lead set
1002-015
500 mA fused test lead set
AVO300 AVO310 AVO410 DCM310 DCM320 DCM330 DCM340
Current ranges
A a.c.
10 A
10 A
True rms
A d.c.
10 A
10 A
Voltage range
V a.c.
Trms
1000 V
V d.c.
1000 V
1000 V
1000 V
Resistance range
Ω
40 M
40 M
Continuity range Buzzer
n
n
0.6 mA, 6 mA,
6 A 10 A
20 A, 200 A,
400 A
40 A, 200 A,
200 A
400 A
750 V
Current ranges a.c.
Data hold
Max conductor size
Safety rating
Warranty upgradeable to 3 years FREE
30 mA, 300 mA, 30 A, 300 A.
n
40 mm
CATIII 300 V
n
60 A, 400 A,
600 A
200 V, 600 V
200 V, 1000 V
200 V, 600 V
200 V, 1000 V
400 V, 600 V
n
1000 V
600, 6 k, 60 k,
600 k, 6 M 60 M
200, 2 k, 200 k, 200, 2 k, 200 k,
2 M, 20 M
2 M, 20 M
n
n
400
n
n
n
n
n
n
27 mm
16 mm
35 mm
Auto-ranging
n
n
n
Backlit display
n
n
Data hold
n
n
n
n
Max hold
n
n
n
27 mm
Conductor size
Other
Warranty upgradeable
to 3 years FREE
Safety rating
Services
and leak
detectors
n
n
n
Earth testers
n
Diode
n
Clamp and
multimeters
400 V, 600 V
DCM300E
60 A, 400 A,
600 A
n
0.6 mA, 6 mA,
6 A 10 A
28 CLAMP AND MULTIMETERS
RCD
testers
Accessories
DCM300E – a high resolution a.c.
current clamp
Loop
testers
The DCM340 is an a.c. and d.c. current
clamp and multimeter that offers
exceptional value and is particularly suited
to solar PV commissioning. It is supplied
blister packed complete with test leads,
batteries, user guide and carry case.
bit.ly/DCM330
For more information go to
bit.ly/DCM300E
n
Industrial
insulation
testers
n
n
n
CATIII 600 V
CATIV 600 V
CATIII 600 V
CATIII 600 V
CATIV 600 V
Network
performance
tester
CATIII 600 V
Cable fault
locator
CATIII 600 V
CLAMP AND MULTIMETERS 29
Prices
16. Digital earth testers
DET3, DET14C and DET24C
Utility detection and
location system
EasyLoc
DET3 series
Digital earth testers
The Easyloc system is the fast, reliable method to detect and
trace underground utility cable runs and pipe networks. It is
simple to operate, with features designed to avoid potentially
dangerous power cables and other services as
effectively as possible.
A
ll models include these features
n
Extra
large selector switch
clear display for easy operation in outdoor conditions
n
Simple one button operation
n
Battery powered with a bar graph indicator
n
Noise reduction up to 40 V peak to peak
n
P54 rated (water/dust ingress) for extra protection in harsh
conditions
n
Comes complete with test leads, stakes, batteries,
calibration certificate and rugged polypropylene carry case
n
Large,
Function
Basic Standard
Passive: power network 50 Hz
n
n
n
n
n
n
Radio
Active: 33 kHz
Line location
Depth measurement without transmitter n
Maximum Marker
Dimensions (W x H x D)
Weight
n
n
n
DET3TC
n
ART or selective three pole earth testing kit
n 2 and 3 pole testing
n Selectable 25 V or 50 V output
When used with the optional ICLAMP, allows fall of potential
testing without the need to disconnect the electrode under test.
n
n
n
40 hours
10 x IEC R6 1.5 V
EasyLoc Tx Transmitter / Generator
n
n
n
n
n
33 kHz continuous or pulsed
Class leading power output
High (0.5 W) and low (0.1 W)
power settings
Simple push-button control
Induction or direct
connection
Induction in two planes of
antenna orientation
Loop
testers
Easyloc Tx transmitter
Transmitted power
0.1 W/0.5 W (switchable)
Frequency
33 kHz
Operating time
6 x IEC R20 1.5 V
Weight
2.6 kg
Dimensions (w x H x D)
14 x 26 25.5 cm
PATs
Certification
software
bit.ly/DET14C_DET24C
Mini leak detector
HL5
The Hydrolux HL 5 is a professional water leak detection unit
offering both visual and audible indication of a leak. It belongs
in the jacket of every facilities engineer and manager as an aid
to on the spot leak detection.
DET24C
1001-810
3-wire earth lead test set
RCD
testers
40 hours
Power supply
For more information go to
DET3 series accessories
Combined
loop RCD
testers
Industrial
insulation
testers
bit.ly/EasyLoc
bit.ly/Megger_DET3T
Part P
kits P
Part
Combined
kits
loop and
RCD testers
Insulation
testers
For more information go to
For more information go to
n
2.5 kg
Operating time
n
Passive location of power and radio
signals
Active location of 33 kHz transmitted
signals
Semi-automatic sensitivity control
Depth measurements in active and passive
modes
Continuous signal strength display
Peak indicator “Easy Locate”
Comfortable handle in line with utility for
comfortable for single-handed operation
Large display with auto backlight
n
Electrical
Electrical
test kits
test kits
10 x 67 26 cm
Power supply
n
Three pole earth testing kit
n 2 and 3 pole testing
n Selectable 25 V or 50 V output
DET3TD offers a complete kit for customers wishing to conduct
earth electrode testing using the 2 and 3 pole techniques.
n
MFT
with
MFT with
certification
certification
x (33 kHz)
n
Depth measurement with transmitter
EasyLoc Receiver
DET3TD
n
x (33 kHz)
Probe location
The Easyloc receiver displays the signal level
detected with a maximum marker for easy
location. The operator works with both the
audio signal and the visual confirmation at
all times. Depth measurement is possible
at the push of a button, even when
using Power Mode.
DET3TC with optional clamp
MFT
MFT
1700 Series
n Pocketsize
n
n
n
n
n
n
n
n
n
n
6220-803
4 right angled adaptors
Mute setting (no static noise in the headphones)
3 optimised filter settings
Excellent, audio characteristics
Optional adapter, for use as a ground microphone
Easy, one-button operation
Immediate detection of leaks
Wireless noise transmission
Built-in LED light for night work
Wireless range 20 m
10 level LED display
Meter
test box
Voltage
detector,
Solar tester
Accessories
Clamp and
multimeters
Special features
Earth testers
n
Perfect for the facilities manager
to help locate water leaks
Services
and leak
detectors
n
Excellent audio characteristics
DET3TD DET3TC DET14C DET24C
Stakeless testing
3-wire testing
n
2-wire testing
n
n
n optimised filter settings
3
n
n
Mute setting (no static noise in
the headphones)
n
n
ART (Attached Rod Technique) enabled
Resistance range Ω
0.01 to 2000
0.01 to 2000
Earth Voltage range
0 to 100 V
n
Display
Digital
Digital
0.05 to 1500
0.5 mA to 35 A
0.5 mA to 35 A
Digital
n
Wireless noise transmission
0 to 100 V
Earth Current range (with optional clamp) A
0.5 mA to 19.9
0.05 to 1500
Digital
Datalogging n
n
Built-in LED light for night work
For more information go to
n
bit.ly/HL5
Downloading
n
30 EARTH TESTERS
Cable fault
locator
Network
performance
tester
Prices
Services and leak detectors 31
17. Cable fault locators
TDR mark3 series
Network Ethernet Tester
NET200
Using a Time Domain Reflectometer (TDR) is a well established
method for finding the location of faults in metallic power or
data cables. In the past TDRs have had a reputation of being
expensive and difficult to use but now, the Megger TDR Mark3
series has put paid to that.
NET200 is the latest, all-in-one network qualification tool. It
measures logical network performance. It provides the roundtrip time (RTT) to measure network speed under dynamic
and static configuration protocol and IP scanning to show
the information on all the terminals connected into the local
network. It can also evaluate the capability of link connections
to support specific network speeds and duplexity (half- or fullduplex).
An AUTO selection option, fast pulse and built in blocking filter
ensures that the most effective selection depending on the
range required, helping rapid diagnosis of the TDR trace. In
addition on the TDR1000/3 and TDR1000/3P, dual cursors allow
complete flexibility, giving the operator full control and instant
indication of distance between two points.
n
n
n
n
n
n
n
n
n
n
The device provides the physical information of the LAN cable
under test such as; Cable length, distance to fault (open or
short) and wire map (pass, fail). With the graphic user interface
supplied by 128x64 LCD and serial communication port, field
engineers can easily apply the device to network testing,
transfer the stored data to their PCs and print reports via
software.
Acurate and easy fault finding because of resolution as low
as 0.1 m
Ultra fast 2 ns pulse for near end fault identification
Trace hold and comparison not TDR500/3
Auto selected output impedance (between 25, 50, 75 and
100 Ω)
Power blocking filter not required
For use on Telecom TNV-3 circuit, or 150 V CAT IV power
circuits
Environmental protection to IP54
High resolution backlit monochrome LCD
Adjustable display contrast
2 year warranty
n
n
n
n
n
n
n
Special features
n
Network Analysis – RTT, Link partner ability,
IP Scan
n
Auto measurement – with selection of tests
n
LAN measurement – Distance, Wiremap,
Crosstalk, Impedance and Continuity
n
Coax capability – graphic or numeric TDR
(selectable)
n
Tone Generator – 1kHz analogue tone
signal
0.2 m to 5000 m
0.2 m to 5000 m
MFT
with
MFT with
certification
certification
Electrical
Electrical
test kits
test kits
Part P
kits P
Part
Combined
kits
loop and
RCD testers
Combined
loop RCD
testers
Insulation
testers
Network qualification in one device
Measures logical network performance
Checks physical condition of cables
Coax and RJ45 connections
Autotest capability
Tone Generator built in
Li-ion battery
Industrial
insulation
testers
Loop
testers
RCD
testers
TDR500/3 TDR1000/3 TDR1000/3P
Range Capability
MFT
MFT
1700 Series
0.2 m to 5000 m
Minimum Pulse 2ns 2ns 2ns
Blocking Filter
Cursors
YES YES YES
PATs
1 2 2
Memory
Trace Hold
Trace Hold with
Live Trace Overlay
Trace Hold with
Live Trace Overlay
Sample Time
Yes Yes Yes
Auto Power Off
Yes
Certification
software
60ns 60ns 60ns
Backlight
Yes
Yes
Test leads
Miniature clip
Miniature clip
Standard clip
10 A fused
CAT Rating
300V CAT III
150V CAT IV
IP Rating
300V CAT III
150V CAT IV
300V CAT III
150V CAT IV
Meter
test box
IP54 IP54 IP54
Voltage
detector,
Solar tester
Accessories
Clamp and
multimeters
Earth testers
Services
and leak
detectors
Cable fault
locator
Network
performance
tester
For more information go to
For more information go to
bit.ly/Megger_ NET200
bit.ly/TDR1000-3
Prices
32 Cable fault locator
Network performance tester 33
18. Price List
Test leads available at
www.megger.com/uk/shop
Price List
Price £
Test leads available at
www.megger.com/uk/shop
Price £
exclusive of VAT
Page 4 and 5
MFT1710
MFT1720
MFT1730
Included
1001-878
6220-810
1001-991
2001-649
Multifunction tester
Multifunction tester with 2-wire auto RCD and phase sequence indicator
Multifunction tester with downloading, rechargeable cells and
3-wire earth testing enabled
Accessories
Spare probes and clips red, blue and green
3-wire earth electrode test set
3-wire 10 A fused lead set red, blue and green with prods and croc clips
100 A current clamp
Charging lead for 12 V vehicle power outlets
Instrument and document carry bag
1002-490
1001-810
1001-975
ICLAMP
6280-332
6420-143
Remote switched probe CAT IV 600 V (not MFT1710)
Socket interface adaptor
3-wire lead set with prods and croc clips
Hard carry case
Page 12
MIT220
MIT230
Pocket-sized insulation and continuity tester 250 V and 500 V
Pocket-sized insulation and continuity tester 250 V, 500 V and 1000 V
1,295.00
Included
1002-001
5410-419
2-wire lead set red and black with prods and croc clips
Hard carry case
29.00
19.00
Accessories
1002-015
5410-346
2-wire 500 mA fused lead set red and black with prods and croc clips
Protective rubber holster
49.00
19.00
49.00
29.00
49.00
29.00
20.00
45.00
55.00
239.00
12.00
39.00
Page 6
MFT1730 On-site
Multifunction tester with downloading, rechargeable cells,
3-wire earth testing and certification software
Included
1001-878
6220-810
1001-991
1001-810
2001-649
1000-632
Remote switched probe CAT IV 600 V
Socket interface adaptor
3-wire lead set with prods and croc clips
3-wire earth electrode test set
Hard carry case
PowerSuite Professional Lite On-site
49.00
29.00
49.00
45.00
29.00
339.00
Accessories
1002-490
6420-143
1002-015
1001-975
ICLAMP
6280-332
Spare probes and clips red, blue and green
Instrument and document carry bag
2-wire 500 mA fused lead set red and black with prods and croc clips
3-wire 10 A fused lead set red, blue and green with prods and croc clips
100 A current clamp
Charging lead for 12 V vehicle power outlets
20.00
39.00
49.00
55.00
239.00
12.00
Page 7
MTK310 test kit
MTK320 test kit
MTK330 test kit
Comprising MIT310, LTW315 and RCDT310
Comprising MIT320, LTW325 and RCDT320
Comprising MIT330, LTW335 and RCDT330
Included
1001-884
6220-740
6220-810
1001-976
1002-001
Remote switched probe (not MTK310)
UK mains test lead set
Socket interface adaptor
2-wire lead set red and green with prods and croc clips
2-wire lead set red and black with prods and croc clips
Accessories
1002-015
1001-977
2-wire 500 mA fused lead set red and black with prods and croc clips
2-wire 10 A fused lead set red and green with prods and croc clips
Page 8
PPK210
PPK220
Electrical test kit comprising of MIT310 and LRCD210
Electrical test kit comprising of MIT320 and LRCD220
Included
6220-740
1001-883
1002-001
5410-418
UK mains test lead set
3-wire lead set with prods and croc clips
2-wire lead set red and black with prods and croc clips
Hard carry case
29.00
39.00
29.00
29.00
Accessories
1002-015
1001-977
6420-143
2-wire 500 mA fused lead set red and black with prods and croc clips
2-wire 10 A fused lead set red and green with prods and croc clips
Instrument and document carry bag
49.00
50.00
39.00
Page 9
LRCD210
LRCD220
Combined non-trip loop and RCD tester
Combined non-trip loop and 1000 mA RCD tester
Included
6220-740
1001-883
5410-409
UK mains test lead set
3-wire lead set with prods and croc clips
Hard carry case
1001-977
2-wire 10 A fused lead set red and green with prods and croc clips
Accessories
exclusive of VAT
765.00
1,095.00
1,455. 00
265.00
339.00
Page 13
MIT400
MIT410
MIT415
MIT420
MIT430
MIT40X
MIT480
MIT481
MIT485
CAT IV 600 V insulation and continuity tester 250 V, 500 V and 1000 V
CAT IV 600 V insulation tester as MIT400 with 50 V 100 V, PI and DAR
CAT IV 600 V insulation and continuity tester 10 V, 25 V, 2 50 V and 500 V
CAT IV 600 V insulation tester as MIT310 with results storage and recall
CAT IV 600 V insulation tester as MIT420 with Bluetooth® downloading
CAT IV 600 V insulation tester voltage selectable from 10 V to 100 V
Telecoms insulation and continuity tester 50 V and 100 V
Telecoms insulation tester 50 V, 100 V, 250 V, 500 V and 1000 V
results storage and recall
Telecoms insulation tester as MIT481 with Bluetooth® downloading
339.00
399.00
399.00
449.00
519.00
439.00
429.00
Included
1002-001
1001-878
5410-420
2-wire silicone lead set red and black with prods and croc clips
Remote switched probe CAT IV 600 V ( not MIT400 or MIT480)
Hard carry case
29.00
49.00
19.00
Accessories
1002-015
6220-860
2-wire 500 mA fused lead set red and black with prods and croc clips
Carry pouch
49.00
39.00
595.00
665.00
Page14 and 15
LTW315
LTW325
LTW335
LTW425
Non-trip 2-wire loop resistance tester 100 v to 280 V
Non-trip 2-wire loop resistance tester 50 v to 480 V with frequency
measurement
Non-trip loop resistance tester as LTW325 with results storage and
downloading
High resolution non-trip loop resistance tester 50 V to 480 V
Included
6220-810
1001-976
5410-409
Socket interface adaptor
2-wire lead set red and green with prods and croc clips
Hard carry case
29.00
29.00
19.00
45.00
29.00
29.00
29.00
29.00
1001-977
2-wire 10 A fused lead set red and green with prods and croc clips
50.00
Included
LT300-EN-00
1001-976
5410-409
CAT IV 300 V high current loop tester with red and green 2-wire lead set
2-wire lead set red and green with prods and croc clips
Hard carry case
369.00
29.00
19.00
49.00
50.00
Included
LT300-EN-BS
6220-810
5410-409
CAT IV 300 V high current loop tester with UK mains test lead
Socket interface adaptor
Hard carry case
369.00
29.00
19.00
Included
LT300-EN-FS
1001-977
5410-409
CAT IV 300 V high current loop tester with 10 A fused test lead set
2-wire 10 A fused lead set red and green with prods and croc clips
Hard carry case
389.00
50.00
19.00
Page 16 and 17
RCDT310
RCDT320
RCDT330
RCD tester 100 V to 280 V
RCD tester 50 V to 280 V with auto RCD test
RCD tester as RCDT320 with result storage and downloading
359.00
409.00
449.00
1,259.00
1,415.00
1,555.00
899.00
1,019.00
Accessories
575.00
29.00
39.00
19.00
1001-977
2-wire 10 A fused lead set red and green with prods and croc clips
50.00
Page 18
PAT320
PAT350
Manual and automatic, dual voltage PAT tester
Manual and automatic, dual voltage PAT tester with flash testing
859.00
1,019.00
50.00
Included
2000-870
2000-881
5310-401
2000-962
Continuity, earth bond and insulation test lead
230 V extension lead test adaptor
Flash test lead (PAT350 only)
Carry case with lead and document pouch
29.00
9.00
29.00
59.00
Accessories
1000-766
6220-639
1000-767
1000-770
2000-551
1000-971
1001-227
2001-044
PATR210
110 V mains supply adaptor
110 V extension lead test adaptor
415 V 4-pin adaptor lead
415 V 5-pin adaptor lead
PC power supply lead test adaptor
PASS labels, roll of 1000
FAIL labels, roll of 1000
Side mounted lead and document pouch for 2000-962
PAT test duplicate record book
29.00
19.00
49.00
49.00
9.00
55.00
55.00
49.00
19.00
Page 10 and 11
MIT300
MIT310
MIT310A
MIT320
MIT330
Installers’ insulation and continuity tester 250 V and 500 V
Installers’ insulation and continuity tester as MIT300 with 1000 V and
600 V voltmeter
Insulation and continuity tester with analogue display
Insulation and continuity tester as MIT310 with resistance
measurement and backlight
Insulation and continuity tester as MIT320 with data storage and
downloading
Included
1002-001
1001-884
5410-409
2-wire lead set red and black with prods and croc clips
Remote switched probe ( MIT320 and MIT330 only)
Hard carry case
29.00
45.00
19.00
1002-015
2-wire 500 mA fused lead set red and black with prods and croc clips
29.00
399.00
359.00
439.00
489.00
Part P
kits P
Part
Combined
kits
loop and
RCD testers
Combined
loop RCD
testers
Insulation
testers
Industrial
insulation
testers
Loop
testers
RCD
testers
PATs
Certification
software
Meter
test box
Voltage
detector,
Solar tester
Accessories
29.00
19.00
49.00
Accessories
299.00
Electrical
Electrical
test kits
test kits
625.00
615.00
UK mains test lead
2-wire lead set red and green with prods and croc clips
(RCDT320 and RCDT330 only)
Hard carry case
Accessories
MFT
with
MFT with
certification
certification
499.00
Included
6220-740
1001-976
5410-409
509.00
595.00
MFT
MFT
1700 Series
Clamp and
multimeters
Earth testers
Services
and leak
detectors
Cable fault
locator
Network
performance
tester
Prices
34 PRICE LIST