1. condensed catalogue 2014
Products for explosive gas atmospheres and areas with combustible dust
Explosion protected electrical equipment
Systems and components for automation
Explosion protected light fittings and
emergency lighting systems
2. 2013-09-10·KP00·III·en
Explosion Protection by R. STAHL - General Catalogue
Sales
R. STAHL
Am Bahnhof 30 · 74638 Waldenburg (Württ.) E
T +49 (0) 79 42 / 943 - 0 · F +49 (0) 79 42 / 943 - 4333
sales_ex@stahl.de · www.stahl.de
Please find your contact person under the sales organisation, see page 588
R. STAHL · www.stahl.de
The newest CD
with the R. STAHL
catalogue can be
obtained from your
R. STAHL partner.
3. Condensed Catalogue 2014
valid as of January 2014
Seite
0 General Information 2
Terms of Sale and Delivery | Pictograms | WebCode
A2 Safety Barriers 4
General | Single-Channel-Safety Barriers | Dual-Channel-Safety Barriers
A3 Isolators 12
Overview | Power Supply | Transmitter | Isolating Repeater | Switching Repeater
Relay Module | Binary Output | HART-Multiplexer | System Components | pac-Bus | pac Carrier
A4 Remote I/O 74
General Information | CPU & Power Modules | BusRail | Temperature Input Modules
Input/Output Modules for Analog Signals | Input/Output Modules for Digital Signals
A5 Fieldbus Technology 118
General Information | Power Supply and Diagnosis | Field Device Coupler | System Components and Accessories
A6 Wireless 140
General Information | WLAN Access Point | Localisation System | WirelessHART Gateway
A7 Operating and Monitoring Systems 152
System Description | Remote HMI | Open HMI | Operator Interfaces Eagle
Operator Interfaces Falcon | Enclosures
A8 Camera and Video Systems 234
Camera Systems for all Areas | Cameras | Video Software
E2 Lighting 254
Compact Light Fittings | Light Fittings for Flourescent Lamps | Tubular Light Fittings | Emergency Light Fittings
LED Cluster Lighting | Pendant Light Fittings | Bulkhead Light Fittings | Floodlights |Portable Lamps | Hand Lamps
E3 Installation Equipment 326
Installation Switches | Junction Boxes | Terminal Boxes | Connection Technology for Data Networks | Plug Connectors
Plugs and Sockets | Couplers | Coupler Sockets | Socket Outlet Assemblies | Maintenance Socket Isolators | Cable Reel
E4 Control Devices 378
Position Switches | Radio Position Switches | Control Equipment for Panel Mounting | Control Device System
Grounding Systems and Grounding Monitoring Devices | Measuring and Monitoring Equipment for Panel Mounting
E5 Signalling Devices 452
Visual Signalling Devices | Audible and Visual Signalling Devices | Audible Signalling Devices | Operator Panels
E6 Components for Heating Systems 496
Junction Boxes for Heat Tracing | Temperature Controller and Limiter | Thermostats | Accessories
E7 Load Disconnect Switches and Motor Starters 514
Safety Switches | Load and Motor Switchgear | Motor Protection Circuit-Breakers | Standard Motor Starters
Direct On-Line Motor Starters | Star-Delta Starter Combinations | Reversing Starter Combinations
E8 Applications Low Voltage Systems 532
Power Distribution | Lighting and Heating Panels | Machine Controls | Battery Boxes
UPS Uninterrupted Power Supply | Pressurized Apparatus
E9 Components for System Solutions 544
Ex d Technology | Ex e Technology | Components for Use in Ex d and Ex e Enclosures
E10 Installation Equipment and Accessories 548
Cable Glands | Cable Glands with Strain Relief | Cable Glands in Brass
Breathing Glands | Stopping Plugs | Accessories
Type Index - Sales Organisation / International 584
Type Index | Addresses
2013-09-10·KP00·III·en Contents 1
4. 0
Condensed Catalogue 2014
Conditions of Sales and Delivery, Pictograms and WebCode
Conditions of Sales and Delivery
The list on hand will be valid as of 2014-01-01.
All lists published up to now, including the technical
specifications and the conditions of sale and delivery,
will then be no longer valid and will be replaced by the
list on hand.
All deliveries and services are based on our
“General Terms and Conditions of Delivery“.
They become an integral part of the contract with each order
and can be viewed under the link:
www.stahl.de / DOWNLOADS
Changes of technical data, dimensions, weights, design and
availability are reserved.
The items in this list form a focus of our program of delivery.
This “Condensed Catalogue“ will be run with a higher
stockpiling of devices and component parts.
With our “Condensed Catalogue“ we want to make your
scheduling and warehousing easier.
If you will favour these devices during construction and project
planning you will secure yourself particularly convenient
delivery times.
You may find the complete delivery program in our
general catalogue and up-to-date in our online-catalogue
www.stahl.de.
Pictograms Application of the Pictograms
Ex Symbol
for all devices in explosion-protected design
Offshore
for all devices that are suitable for offshore applications. When the materials are
selected special importance is put on the harsh conditions of seawater atmosphere.
Shipping
for all devices with ship approval
Low temperature
for all devices that may be used in temperatures below -20 °C
High temperature
for all devices that may be used in temperatures higher than +40 °C
R. STAHL Schaltgeräte GmbH
Product Segments PS
In the present “Condensed Catalogue“ you will find an
associated product segment with every item number.
This allows a computerized classification of defined
product segments and delivery conditions.
Mark-up for small-volume purchases
For purchase orders with a net order value < 100 Euro we will
charge a mark-up for small-volume purchases of 25 Euro net.
Cancellation
We will charge a processing fee of 50 Euro net for the
cancellation of an order. With special productions according to
the orders the cancellation costs will depend on the production
stage.
Repurchase
Repurchases are only possible for unopened regular stock
on hand, within 6 months after delivery and only with prior
consultation. If the goods have been returned freight prepaid
and after the quality of the returned goods has been accepted
we will credit 70% of the product invoice value.
2 2013-09-10·KP00·III·en
5. 0
Condensed Catalogue 2014
Conditions of Sales and Delivery, Pictograms and WebCode
WebCode Description
By entering the WebCode on our homepage www.stahl.de you will be led directly
WebCode XXXXXXX to the respective documents.
WebCode Example: Installation Switch Series 8030/51
WebCode 8030A
2013-09-10·KP00·III·en R. STAHL Schaltgeräte GmbH 3
7. A2
Contents
Safety Barriers
Single-Channel Safety Barriers INTRINSPAK 9001 6
Dual-Channel Safety Barriers INTRINSPAK 9002 8
Safety Barriers with Electronic Current Limitation INTRINSPAK 9004 10
You will find further information on the Internet www.stahl.de
General Information
Engineering
Application Examples
Accessories and Spare Parts
2013-09-10·KP00·III·en Safety Barriers 5
8. A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
Safety Barriers
Series 9001 / 9002 / 9004
Series 9001 / 9002 / 9004 A2
10064E00
9001: WebCode 9001A
> Complete product range for all standard
applications
> Flexible and space saving - single and
dual channel versions on 12 mm only
> Time-saving installation thanks to
simultaneous
– snapping onto the rail and
– connecting to PE and earth
> Reduced inventory due to uniform
exchangeable fuse
9002: WebCode 9002A
9004: WebCode 9004A
ATEX / IECEX NEC 505 NEC 506 NEC 500
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
9001, 9002:
x x x x x x 9001, 9002:
Ex i interfaces
9004:
Ex i interfaces
x x x x 9004:
Installation in x x Installation in x x Installation in x x*) x*)
*) Restrictions see table explosion protection
Class I Class I Class II Class III
Ex i interfaces
9001, 9002:
Ex i interfaces
x x x x x x
Ex i interfaces
9004:
Ex i interfaces
x x x
Technical Data
Version 9001 9002 9004
Explosion protection
Global (IECEx)
Gas and dust IECEx PTB 09.0001X IECEx PTB 08.0057X IECEx PTB 12.0003X
Ex nA [ia Ga] IIC T4 Gc
[Ex ia Da] IIIC
Ex nA [ia Ga] IIC T4 Gc
[Ex ia Da] IIIC
Ex nA [ib Gb] IIC T4 Gc
Ex nA [ib Gb] IIB T4 Gc
[Ex ib Db] IIIC
Europe (ATEX)
Gas and dust PTB 01 ATEX 2088 X PTB 01 ATEX 2053 X PTB 02 ATEX 2008
E II 3 (1) G Ex nA [ia Ga]
IIC/IIB T4 Gc
E II (1) D [Ex ia Da] IIIC
E II 3 (1) G Ex nA [ia Ga]
IIC/IIB T4 Gc
E II (1) D [Ex ia Da] IIIC
E II (2) GD [EEx ib] IIB/IIC
E II 3 G EEx nA II T4
(Installation in Zone 2)
Certifications and certificates
Certificates IECEx, ATEX, Canada (CSA),
Kazakhstan
(operating licence),
Russia (GOST R),
Serbia (SRPS), Ukraine (TR),
Belarus (operating
authorisation)
IECEx, ATEX, Canada (CSA),
Kazakhstan
(operating licence),
Russia (GOST R),
Serbia (SRPS), Ukraine (TR),
USA (FM, UL), Belarus
(operating authorisation)
IECEx, ATEX, Canada (CSA),
Kazakhstan
(operating authorisation),
Russia (GOST R),
Serbia (SRPS), Ukraine (TR),
Belarus (operating
authorisation)
Further parameters
Installation in Zone 2, Division 2 and in safe area
Further information see respective certificate and operating instructions
Enclosure material Polyamide 6 GF
Degree of protection
according to IEC 60529
terminal enclosure:
housing:
IP20
IP40
Connection type 4 cage terminals, each maximum 1.5 mm2 flexible / solid
2 PA-terminals, each maximum 4 mm2 flexible / solid
Ambient temperature
Ambient temperature -20 ... +60 °C
Storage -20 ... +75 °C
Dimensions 12 x 104 x 70 mm
Weight approx. 0.115 kg
6 Safety Barriers 2013-09-10·KP00·III·en
9. A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
Safety Barriers
Series 9001 / 9002 / 9004
Selection table
UN Rmax Safety data Schematic Order number Art. no. PS
Uo Io Po
V Ω V mA mW
Single-Channel Safety Barriers for Negative Polarity Series 9001/00
6 32 8.6 390 839 Pic. A 9001/00-086-390-101 158434 20
24 375 28 85 595 Pic. A 9001/00-280-085-101 158344 20
319 28 100 700 Pic. A 9001/00-280-100-101 158356 20
Single-Channel Safety Barriers for Positive Polarity Series 9001/01
6 27 8.3 442 917.2 Pic. B 9001/01-083-442-101 158338 20
218 8.6 50 107.5 Pic. B 9001/01-086-050-101 158379 20
73 8.6 150 322.5 Pic. B 9001/01-086-150-101 158418 20
32 8.6 390 839 Pic. B 9001/01-086-390-101 158439 20
8 106 12.6 150 473 Pic. B 9001/01-126-150-101 158502 20
12 135 15.8 150 593 Pic. B 9001/01-158-150-101 158535 20
53 15.8 390 1541 Pic. E 9001/01-158-390-101 158509 20
262 16.8 75 315 Pic. B 9001/01-168-075-101 158568 20
16 241 19.9 100 498 Pic. B 9001/01-199-100-101 158632 20
168 19.9 150 746 Pic. B 9001/01-199-150-101 158638 20
66 19.9 390 1940 Pic. E 9001/01-199-390-101 158519 20
20 ... 35 505 25.2 57 359 Pic. C 9001/01-252-057-141 158689 20
505 25.2 60 378 Pic. D 9001/01-252-060-141 158693 20
268 25.2 100 630 Pic. M 9001/01-252-100-141 158697 20
24 666 28 50 350 Pic. B 9001/01-280-050-101 158665 20
375 28 85 595 Pic. B 9001/01-280-085-101 158351 20
319 28 100 700 Pic. B 9001/01-280-100-101 158365 20
294 28 110 770 Pic. B 9001/01-280-110-101 158380 20
198 28 165 1155 Pic. B 9001/01-280-165-101 158392 20
124 28 280 1960 Pic. E 9001/01-280-280-101 158722 20
Single-Channel Safety Barriers for Alternating Polarity Series 9001/02
0.7 134 1.6 15 6 Pic. F 9001/02-016-015-101 158669 20
43 1.6 50 20 Pic. F 9001/02-016-050-101 158673 20
20 1.6 150 60 Pic. F 9001/02-016-150-101 158681 20
20.1 1.6 150 60 Pic. F 9001/02-016-150-111 158685 20
6 354 9.3 30 69.8 Pic. F 9001/02-093-030-101 158743 20
79 9.3 150 348.8 Pic. F 9001/02-093-150-101 158753 20
36 9.3 390 906.8 Pic. F 9001/02-093-390-101 158755 20
Single-Channel Diode Return Barriers for Positive Polarity Series 9001/03
16 – – 19.9 0 0 Pic. G 9001/03-199-000-101 158475 20
24 – – 28 0 0 Pic. G 9001/03-280-000-101 158486 20
Single-Channel Safety Barriers for Transmitter Series 9001/51
20 ... 35 – – 28 110 770 Pic. K 9001/51-280-110-141 158530 20
– – 28 91 637 Pic. L 9001/51-280-091-141 158524 20
2013-09-10·KP00·III·en Safety Barriers 7
10. A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
Safety Barriers
Series 9001 / 9002 / 9004
Schematic for Single-Channel Safety Barriers Series 9001
Picture A Picture B Picture C
Picture D Picture E Picture F
+ UN + U
N Ex i
Picture G Picture K Picture L
Picture M
Selection table
Channel UN Rmin Rmax Safety data Schematic Order number Art. no. PS
V Ω Ω V mA mW
Dual-Channel Safety Barriers Polarity: - / - Series 9002/00
12
1+2
22.5
17.5
- -
321
416
- -
Dual-Channel Safety Barriers Polarity: + / - Series 9002/10
12
1+2
66
- -
490
490
- -
12
1+2
66
- -
42
42
- -
Safety Barriers
09405E00 09406E00 09407E00
09408E00 09409E00 09410E00
09411E00 09415E00 09416E00
09417E00
Uo Io Po
358
463
- -
26
20
26
87
51
138
540
245
785
Pic. C 9002/00-260-138-001 158867 20
543
543
- -
9.33
9.33
18.7
20
20
20
50
50
90
Pic. A 9002/10-187-020-001 158937 20
49
49
- -
9.33
9.33
18.7
270
270
270
630
630
1260
Pic. A 9002/10-187-270-001 158933 20
8 2013-09-10·KP00·III·en
12. A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
Safety Barriers
Series 9001 / 9002 / 9004
Schematic for Dual-Channel Safety Barriers Series 9002
Picture A Picture B Picture C
Picture E Picture F Picture G
Picture H Picture I Picture J
Picture K Picture M Picture N
Selection table
UN Rmax Safety data Schematic Order number Art. no. PS
V Ω V mA mW
Single-Channel Safety Barriers with Electronic Current Limitation for Positive Polarity Series 9004/01
12 30 16.8 50 840 Pic. A 9004/01-168-050-001 159060 20
24 56 28 45 1260 Pic. A 9004/01-280-045-001 159082 20
26 73 31.5 25 787.5 Pic. A 9004/01-315-025-001 159086 20
Single-Channel Safety Barriers with Electronic Current Limitation for Positive Polarity with Voltage Limitation Series 9004/51
23 ... 27 – – 20.6 50 1030 Pic. B 9004/51-206-050-001 159090 20
Schematic
Single-Channel Safety Barriers with Electronic Current Limitation, Polarity +
Picture A Picture B
Safety Barriers
09418E00 09419E00 09420E00
09422E00 09423E00 09424E00
09425E00 09426E00 09427E00
09428E00 09430E00 11030E00
Uo Io Po
10013E00 10014E00
10 2013-09-10·KP00·III·en
14. Isolators
Isolators
Overview of the System Components ISpac 14
General ISpac 15
Applications ISpac 16
Ex i Isolators
Power Supply
Ex i Power Supply ISpac 9143 18
Transmitter
Frequency Transmitter ISpac 9146 20
Vibration Transducer Supply Unit ISpac 9147 22
Transmitter Supply Unit ISpac 9160 24
Transmitter Supply Unit with Limit Value ISpac 9162 26
Temperature Transmitter ISpac 9182 50
Isolating Repeater
Isolating Repeater HART Input ISpac 9163 28
mA-Isolating Repeater ISpac 9164 30
Isolating Repeater ISpac 9165 32
Isolating Repeater Loop Powered ISpac 9167 34
Resistance Isolator ISpac 9180 48
12 Isolators 2013-09-10·KP00·III·en
15. A3
Contents
Ex i Isolators
Isolating Repeater
Fieldbus Isolating Repeater ISpac 9185 52
Fibre Optics Fieldbus Isolating Repeater ISpac 9186 54
Switching Repeater
Switching Repeater ISpac 9170 36
Relay Module
I.S. Relay Module ISpac 9172 38
Electronic Relay ISpac 9174 40
Binary Output
Binary Output ISpac 9175 42
Binary Output with Line Fault Transparency ISpac 9175 44
Binary Output without Power Supply ISpac 9176 46
Non - Ex i Isolators
Transmitter
Transmitter Supply Unit ISpac 9160 66
Transmitter Supply Unit with Limit Value ISpac 9162 67
mA-Isolating Repeater ISpac 9164 68
Isolating Repeater ISpac 9165 69
Isolating Repeater Loop Powered ISpac 9167 70
Relay Module ISpac 9172 71
Temperature Transmitter ISpac 9182 73
System Components
Supply Module ISpac 9193 58
HART Termination Board ISpac 9196 64
HART-Multiplexer ISpac 9192 56
pac-Bus ISpac 9194 60
pac-Carrier ISpac 9195 62
You will find further information on the Internet www.stahl.de
Engineering ISpac
2013-09-10·KP00·III·en Isolators 13
16. A3
General
Overview of the System Components
Asset
Management
Level
Control Level
Control Level
Zone 2 / Division 2
Control Level
Zone 1 / Division 1
Isolators
Field Circuit Non-Ex i
15801E00
PLC / DCS PLC / DCS
Classic / HART
meld devices
Classic / HART
meld devices
Field Circuit Ex i
14 2013-09-10·KP00·III·en
17. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
General
A3
11748E00
WebCode ISpacA
> Versions Ex i and non-Ex i
> All functions with 2 channels per module
> Galvanic isolation between inputs, outputs and
power supply
> Modules for DIN-rail installation or comfortable
system integration via pac-Carrier
> Detachable terminals available in screw terminal
and spring clamp terminal versions
> Extended temperature range -20 … +70 °C
> Installation possible in Zone 2 resp. Div. 2
> Most isolator versions can be used for applications
according to „functional safety“ SIL (IEC 61508)
> Customer specific engineering by
R. Stahl’s competence center
> macros for easier planning and
engineering available
ATEX / IECEx NEC 505 NEC 506 NEC 500
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Ex i
x x x x x x Ex i
interface
Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)
*) Restrictions see table explosion protection
Class I Class I Class II Class III
interface
x x x Ex i
interface
x x x x x x
Technical Data
Mounting type on DIN-rail (NS35/15, NS35/7.5) or in pac-Carrier
Versions - Screw terminals (standard)
- Spring clamp terminals
Removable, for wire cross-section 0.2 ... 2.5 mm2 or 2 x 1.5 mm2 flexible with or
without splay protection or single-wire
Degree of protection
Enclosure IP30
Terminals IP20
Ambient conditions
Ambient temperature
Single device -20 ... +70 °C
Group assembly -20 ... +60 °C
The installation conditions affect the ambient temperature.
Observe operating instructions.
Storage temperature -40 ... +80 °C
Galvanic isolation Between inputs, outputs and power supply
Voltage range 18 ... 31.2 V DC / 96 ... 253 V AC (only 9170)
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO), Canada (CSA), Kazakhstan (GOST K), Korea (KCs),
Russia (GOST R), Serbia (SRPS), Ukraine (TR), USA (FM, UL), Belarus (operating authorisation)
Ship approval DNV
Installation in Zone 2, Div. 2 and in the safe area
Dimensional Drawings (All Dimensions in mm / inches) - Subject to Alterations
06812E00
122 mm / 4.80 "
X
99 mm / 3.90 " Y
114,5 mm / 4.51 "
Dim. X
Screw terminals 108 mm / 4.25 in
Spring clamp terminals 128 mm / 5.04 in
Dim. Y
Series 9143, 9185, 9192 35.2 mm / 1.39 in
Series 9146, 9147, 9160, 9162,
17.6 mm / 0.69 in
9163, 9165, 9167, 9170, 9172,
9175, 9176, 9180, 9182, 9193
2013-09-10·KP00·III·en Isolators 15
18. A3
ISpac
Application of isolators
Symbol Application ISpac Type Ex i
Isolators
Signal circuit
Non Ex i
Signal circuit
06861E00
2-, 3-, 4-wire transmitters and
current sources
9160
9162 (with limit value)
Page 24
Page 26
Page 66
Page 67
06329E00
2-wire HART transmitter 9160
9162 (with limit value)
Page 24
Page 26
Page 66
Page 67
07649E00
4-wire HART transmitter 9163
9164
Page 28
Page 30 Page 68
06321E00
I/P converter, HART control valve 9165
9167
Page 32
Page 34
Page 69
Page 70
06331E00
Resistance thermometers /
Resistance temperature detectors
(RTD)
9182
9180
Page 50
Page 48
Page 72
06332E00
Thermocouple 9182 Page 50 Page 72
06333E00
Contact, optocouple output 9170
9172
Page 36
Page 38
06334E00
NAMUR proximity switch 9170 Page 36
06326E00
Speed control,
Flow measurement
9146 Page 20
06324E00
Solenoid valve,
LED indicating lamp, horn
9175
9176
9172
9174
Page 42
Page 46
Page 38
Page 40
Page 71
06327E00
Fire & gas detectors 9167 Page 34 Page 70
16 2013-09-10·KP00·III·en
19. A3
ISpac
Application of isolators
Symbol Application ISpac Type Ex i
06317E00
Alarm contact 9146
9162
9182
Signal circuit
Page 20
Page 26
Page 50
Non Ex i
Signal circuit
Page 67
Page 72
06330E00
HART Multiplexer 9192
9196
Page 56
Page 64
06328E00
Modbus, Profibus DP,
ServiceBus R.STAHL
9185
9186
Page 52
Page 54
06318E00
Power supply of
intrinsically safe users
9143 Page 18
06892E00
Vibration sensor 9147 Page 22
15280E00
Voltage source 9163 Page 28
HART
Ex i
V
2013-09-10·KP00·III·en Isolators 17
20. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Ex i Power Supply
Field Circuit Ex i
Series 9143
Series 9143 A3
07673E00
WebCode 9143A
> For intrinsically safe power supply of
3- or 4-wire transmittters and controllers
> Intrinsically safe output [Ex ib] IIC/IIB
> Stable output voltage
> Galvanic isolation between output and
power supply
> Power supply 24 V AC / DC or 85 ... 230 V AC
> Compact design
ATEX / IECEx
Zone 0 1 2 20 21 22
Ex i interface x x x x
Installation in x*) x*)
*) Restrictions see table explosion protection
Selection Table
Version Auxiliary power Ex i output Order number Art. no. PS
Nominal voltage
UN
Max. nominal
current IN
Ex i power supply
Series 9143
24 V AC / DC 4.0 ... 5.6 V 160 mA 9143/10-065-200-10s 159820 29
9.5 ... 11.8 V 130 mA 9143/10-124-150-10s 159823 29
12.5 ... 14.7 V 140 mA 9143/10-156-160-10s 159797 29
14.6 ... 17.6 V 35 mA 9143/10-187-050-10s 159800 29
115 / 230 V AC 4.0 ... 5.6 V 160 mA 9143/10-065-200-20s 159785 29
9.5 ... 11.8 V 130 mA 9143/10-124-150-20s 159791 29
12.5 ... 14.7 V 140 mA 9143/10-156-160-20s 159829 29
14.6 ... 17.6 V 35 mA 9143/10-187-050-20s 159832 29
Note Other versions - see Automation Catalogue
The order code above is with screw type removable terminals.
Technical Data
Explosion protection
Version 9143/10-...-...-10.
24 V AC / DC
9143/10-...-...-20.
115 / 230 V AC
Global (IECEx)
Gas, dust and mining IECEx BVS 12.0009X IECEx BVS 12.0009X
Ex nA [ib Gb] IIC/IIB T4 Gc
[Ex ib Db] IIIC
[Ex ib Gb] IIC/IIB
[Ex ib Db] IIIC
[Ex ib Mb] I [Ex ib Mb] I
Europe (ATEX)
Gas, dust and mining BVS 05 ATEX E 152X BVS 05 ATEX E 152X
E II 3 (2) G Ex nA [ib Gb] IIC/IIB T4 Gc
E II (2) D [Ex ib Db] IIIC
E II (2) G [Ex ib Gb] IIC/IIB
E II (2) D [Ex ib Db] IIIC
E I (M2) [Ex ib Mb] I E I (M2) [Ex ib Mb] I
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO), India (PESO), Canada (CSA), Kazakhstan (GOST K),
Korea (KCs), Russia (GOST R), Serbia (SRPS), Belarus (operating authorisation)
Ship approval DNV
18 Isolators 2013-09-10·KP00·III·en
21. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Ex i Power Supply
Field Circuit Ex i
Series 9143
Technical Data
Safety data
Version 9143/10-065-200-.0. 9143/10-124-150-.0. 9143/10-156-160-.0. 9143/10-187-050-.0.
Max. voltage Uo 6.5 V 12.4 V 15.6 V 18.7 V
Max. current Io 200 mA 150 mA 160 mA 50 mA
Max. power Po 1.3 W 1.86 W 2.496 W 0.935 W
Further parameters
Version 9143/10-...-...-10.
24 V AC / DC
9143/10-...-...-20.
115 / 230 V AC
Installation in Zone 2, 22 and in the safe area in Zone 22 and in the safe area
Further information see respective certificate and operating
instructions
see respective certificate and operating
instructions
Auxiliary power
Version 9143/10-...-...-10.
24 V AC / DC
9143/10-...-...-20.
115 / 230 V AC
Rated voltage UN 24 V AC / DC 115 / 230 V AC
Voltage range AC: 20 ... 28 V
DC: 18 ... 35 V
85 ... 230 V AC
2013-09-10·KP00·III·en Isolators 19
22. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Frequency Transmitter
Field Circuit Ex i
Series 9146
Series 9146 A3
11024E00
WebCode 9146A
> Speed control of rotating parts
in hazardous areas
> Most compact device in its class,
2 versions available:
– limit value switch, frequency/current
conversion, impulse divider function
within 17.6 mm width
– dual channel frequency/current conversion
within 17.6 mm width
> Line fault monitoring indicated by LED and
fault-contact contact enables easy monitoring
and prompt troubleshooting
> Broad input frequency range 0.001 ... 20 kHz
ATEX / IECEx NEC 505 NEC 506 NEC 500
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x x
Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)
*) Restrictions see table explosion protection
Class I Class I Class II Class III
Selection Table
Version Channels Output Limit value contact
(per channel)
Impulse output Order number Art. no. PS
Frequency Transmitter
Field Circuit Ex i
Series 9146
1 0/4 ... 20 mA 2 NO / NC one NO selectable 9146/10-11-12s 159883 21
2 0/4 ... 20 mA without one NO selectable 9146/20-11-11s 159886 21
Note The order numbers listed in the table are for devices equipped with screw-type terminals.
For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with
"k" for spring-type terminals.
Technical Data
Explosion protection
Global (IECEx)
Gas, dust and mining IECEx BVS 13.0095X
Ex nA nC [ia Ga] IIC T4 Gc
[Ex ia Da] IIIC
[Ex ia Ma] I
Europe (ATEX)
Gas and dust BVS 05 ATEX E 0171 X
E II 3 (1) G Ex nAc nCc [ia] IIC T4
E II (1) D [Ex ia] IIIC
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO), India (PESO), Canada (cFM), Kazakhstan (GOST K),
Russia (GOST R), Serbia (SRPS), USA (FM), Belarus (operating authorisation)
Ship approval DNV
Safety data
Max. voltage Uo 10.5 V
Max. current Io 23.4 mA
Max. power Po 61.4 mW (linear characteristic curve)
20 Isolators 2013-09-10·KP00·III·en
23. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Frequency Transmitter
Field Circuit Ex i
Series 9146
Technical Data
Auxiliary power
Nominal voltage UN 24 V DC
Nominal current at UN, 20 mA
1 channel 55 mA
2 channels 75 mA
Ex i input
Input signal acc. to EN 60947-5-6 (NAMUR)
Input frequency 0.001 ... 20000 Hz
Output see selection table
Error detection Ex i input
Message of line fault and
auxiliary power failure
- contact (30 V / 100 mA) closed to earth in case of error
- pac-Bus, potential-free contact (30 V / 100 mA)
2013-09-10·KP00·III·en Isolators 21
24. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Vibration Transducer Supply Unit
Series 9147
Series 9147 A3
14793E00
WebCode 9147A
> For vibration, acceleration and speed
sensors in 2- and 3-wire design
> Space-saving dual-channel version
> Signal frequencies up to 50 kHz
> Easy setting by means of front-side
rotary switch
> Galvanic isolation between inputs and
outputs and auxiliary power
> For use up to SIL 2 (IEC 61508)
ATEX / IECEx
Zone 0 1 2 20 21 22
Ex i interface x x x x x x
Installation in x*) x*)
*) Restrictions see table explosion protection
Selection table
Version Channels Order number Art. no. PS Weight
kg
Vibration transducer
supply unit
Series 9147
1 9147/10-99-10s 212432 21 0.150
2 9147/20-99-10s 212433 21 0.210
Note The order numbers listed in the table are for devices equipped with screw-type terminals.
For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with
"k" for spring-type terminals.
Technical Data
Explosion protection
Global (IECEx)
Gas, dust and mining IECEx BVS 12.0001 X
Ex nA [ia Ga] IIC T4 Gc
[Ex ia Da] IIC
[Ex ia Ma] I
Europe (ATEX)
Gas, dust and mining BVS 12 ATEX E 007 X
E II 3 (1)G Ex nA [ia Ga] IIC T4 Gc
E II (1)D [Ex ia Da] IIC
E I (M1) [Ex ia Ma] I
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO), Canada (FMc), Kazakhstan (GOST K),
Russia (GOST R), USA (FM)
Ship approval DNV
Safety data
Max. voltage Uo 26.3 V
Max. current Io 88.3 mA
Max. power Po 579 mW
Insulation voltage Um 253 V
Further parameters
Installation in Zone 2
Further information see respective certificate and operating instructions
22 Isolators 2013-09-10·KP00·III·en
25. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Vibration Transducer Supply Unit
Series 9147
Technical Data
Electrical data
Version 1 channel
9147/10-99-10
2 channels
9147/20-99-10
Auxiliary power
Nominal voltage UN 24 V DC 24 V DC
Voltage range 18 ... 31.2 V 18 ... 31.2 V
Residual ripple within
( 3.6 VSS ( 3.6 VSS
voltage range
Nominal current at UN
1 channel 75 mA – –
2 channels – – 88 mA
Power consumption at UN
1 channel 1.8 W – –
2 channels – – 2.1 W
Power dissipation at UN
1 channel 1.4W – –
2 channels – – 1.8W
Polarity reversal protection yes yes
Operation indication LED green "PWR" LED green "PWR"
Undervoltage monitoring yes (no faulty devices / output states) yes (no faulty devices / output states)
Ex i input
Input resistance 10 kΩ
Input signal -20 ... -0.5 V
Functional range -24 ... 0 V
Output current
For 3-wire operation
For 2-wire operation
Output
10 mA at -21 V
20 mA at -18 V
2.6 / 4.3 / 7.9 mA at -10 V
Output signal -20 ... -0.5 V
Internal resistance < 30 Ω
Load resistance
1 channel > 2 kΩ
2 channels > 10 kΩ
Signal transmission
Delay input / output < 7 μs
Phase fluctuation < 0.6 % / period
Transferable frequency range 0 ... 50 kHz
Ripple at a load resistance of
< 60 mVss
10 kΩ
Error limits
relative to the measuring span -0.5 ... -20 V
Temperature influence < 0.05 % / 10 K
Auxiliary power influence < 0.05 %
Load resistance influence
At RL = 3 ... 10 kΩ < 0.35 % / kΩ
DC transmission fault
At UN and 20 °C < 0.5 %
AC transmission fault
At UN and 20 °C
Frequency Phase fault Amplitude fault
0 ... 200 Hz ( 0.5° ±1 %
< 400 Hz ( 1.0° ±1 %
> 600 Hz ( 1.5° ±1 %
< 1 Hz ( 2.5° ±1 %
< 10 kHz ( 25° +1 / -5 %
< 20 kHz ( 50° +1 / -5 %
< 50 kHz ( 125° -30 %
Electromagnetic compatibility Tested to the following standards and regulations:
EN 61326-1 Use in industrial environment
2013-09-10·KP00·III·en Isolators 23
26. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Transmitter Supply Unit
Field Circuit Ex i
Series 9160 Rev. F
Series 9160 Rev. F A3
09745E00
WebCode 9160A
> Suitable for 2-, 3-wires transmitter,
2-wires HART transmitter and mA-sources
(4-wires transmitter)
> Intrinsically safe input [Ex ia] IIC
> Galvanic isolation between input,
output and power supply
> Open-circuit and short-circuit monitoring
and messaging for input and output
(can be switched off)
> For use up to SIL 2,
special version up to SIL 3 (IEC 61508)
> High accuracy
ATEX / IECEx
Zone 0 1 2 20 21 22
Ex i interface x x x x x x
Installation in x*) x*)
*) Restrictions see table explosion protection
Variants with UL/FM approval for NEC on request
Selection Table
Output version
(control)
Channels Input Output A Output B SIL LFD* Order number Art. no. PS
0/4 ... 20 mA
active / source
with HART
1 0/4 ... 20 mA 0/4 ... 20 mA – – 2 no 9160/13-11-10s 214893 21
3 yes 9160/13-11-13s 214897 21
0/4 ... 20 mA 2 no 9160/19-11-10s 214901 21
0/4 ... 20 mA
High Power
0/4 ... 20 mA – – 2 yes 9160/14-11-11s 214899 21
2 0/4 ... 20 mA 0/4 ... 20 mA 0/4 ... 20 mA 2 no 9160/23-11-10s 214905 21
0/4 ... 20 mA
passive / sink
with HART
1 0/4 ... 20 mA passive – – 2 no 9160/13-10-10s 214837 21
2 0/4 ... 20 mA passive passive 2 no 9160/23-10-10s 214903 21
Note The order numbers listed in the table are for devices equipped with screw-type terminals.
For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with
"k" for spring-type terminals.
* LFD - line fault diagnosis
no - Device transmits line fault on the field side via the 4 ... 20 mA signal. Without LED / relay contact.
yes - Device transmits line fault on the field side via the 4 ... 20 mA signal. With LED / relay contact.
24 Isolators 2013-09-10·KP00·III·en
27. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Transmitter Supply Unit
Field Circuit Ex i
Series 9160 Rev. F
Technical Data
Output version (control) 0/4 ... 20 mA active / source with HART
Version 9160/xx-11-10 9160/xx-11-13 9160/14-11-11
Explosion protection
Global (IECEx)
Gas, dust and mining IECEx BVS 08.0050X IECEx BVS 08.0050X
Ex nA [ia Ga] IIC T4 Gc
[Ex ia Da] IIIC
[Ex ia Ma] I
Ex nA nC [ia Ga] IIC T4 Gc
[Ex ia Da] IIIC
[Ex ia Ma] I
Europe (ATEX)
Gas, dust and mining DMT 03 ATEX E 010 X DMT 03 ATEX E 010 X
E II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
E II (1) D [Ex ia Da] IIIC
E I (M1) [Ex ia Ma] I
E II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc
E II (1) D [Ex ia Da] IIIC
E I (M1) [Ex ia Ma] I
Certifications and certificates
Certificates IECEx, ATEX, Brasil (INMETRO), Kazakhstan (GOST K), Russia (GOST R), Serbia (SRPS),
Ukraine (TR), Belarus (operating athorisation)
Ship approval DNV
Version 9160/xx-11-10 9160/xx-11-13 9160/14-11-11
Safety data
Max. voltage Uo 27 V 27 V 27 V
Max. current Io 88 mA 88 mA 112.5 mA
Max. power Po 576 mW 576 mW 731 mW
Auxiliary power
Nominal voltage UN 24 V DC 24 V DC 24 V DC
Nominal current at UN, 20 mA
1 channel 75 mA 95 mA 95 mA
2 channels 115 mA – – – –
Ex i input
Input signal 0/4 ... 20 mA with HART 0/4 ... 20 mA with HART 0/4 ... 20 mA with HART
Supply voltage for transmitter ) 16 V at 20 mA
(for 2-, 3-wire)
) 16 V at 20 mA
(for 2-, 3-wire)
) 18 V at 20 mA
(for 2-, 3-wire)
Output
Output signal 0/4 ... 20 mA with HART 0/4 ... 20 mA with HART 0/4 ... 20 mA with HART
Load resistance RL 0 ... 600 Ω
(terminal 1+ / 2- or 5+ / 6-)
0 ... 379 Ω
(terminal 3+ / 2- or 4+ / 6-)
(with internal 221 Ω resistor
for HART)
0 ... 600 Ω
(terminal 1+ / 2-)
0 ... 379 Ω
(terminal 3+ / 2-)
(with internal 221 Ω resistor
for HART)
0 ... 600 Ω
(terminal 1+ / 2- or 5+ / 6-)
0 ... 379 Ω
(terminal 3+ / 2- or 4+ / 6-)
(with internal 221 Ω resistor
for HART)
Output version (control) 0/4 ... 20 mA passive / sink with HART
Version 9160/xx-10-10
Explosion protection
Global (IECEx)
Gas, dust and mining IECEx BVS 08.0050X
Ex nA nC [ia Ga] IIC T4 Gc
[Ex ia Da] IIIC
[Ex ia Ma] I
Europe (ATEX)
Gas, dust and mining DMT 03 ATEX E 010 X
E II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc
E II (1) D [Ex ia Da] IIIC
E I (M1) [Ex ia Ma] I
Certifications and certificates
Certificates IECEx, ATEX, Brasil (INMETRO), Kazakhstan (GOST K), Russia (GOST R), Serbia (SRPS),
Ukraine (TR), Belarus (operating athorisation)
Ship approval DNV
Safety data
Max. voltage Uo 27 V
Max. current Io 88 mA
Max. power Po 576 mW
Auxiliary power
Nominal voltage UN 24 V DC
Nominal current at UN, 20 mA
1 channel 75 mA
2 channels 115 mA
Ex i input
Input signal 0/4 ... 20 mA with HART
Supply voltage for transmitter ) 16 V at 20 mA (for 2-, 3-wire)
Output
Output signal Current sink, max. 30 V with HART
Load resistance RL see data sheet
2013-09-10·KP00·III·en Isolators 25
28. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Transmitter Supply Unit with Limit Contact
Field Circuit Ex i
Series 9162
Series 9162 A3
11025E00
WebCode 9162A
> Compact limit value switch with
2 configurable limiting values and
0/4 ... 20 mA or 4 ... 20 mA output
> Suitable for 2-, 3-wire transmitter,
2-wire HART transmitter and mA-sources
> Intrinsically safe input [Ex ia] IIC
> Open circuit / short-circuit monitoring
and messaging
> Variant for use up to SIL 2 (IEC 61508)
ATEX / IECEx NEC 505 NEC 506 NEC 500
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Ex i
x x x x x x Ex i
interface
Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)
*) For restrictions, see Explosion protection table
Class I Class I Class II Class III
interface
x x x Ex i
interface
x x x x x x
Selection Table
Version Channels Input Output Limit contact SIL Order number Art. no. PS
Transmitter supply unit
1 0/4 ... 20 mA
0/4 ... 20 mA
2 NO / NC – – 9162/13-11-12s 160120 21
with limit contact
with HART
with HART
Series 9162
4 ... 20 mA
with HART
4 ... 20 mA
with HART
2 NO / NC 2 9162/13-11-14s 202460 21
Note The order numbers listed in the table are for devices equipped with screw-type terminals.
For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with
"k" for spring-type terminals.
Technical Data
Version 9162/13-11-12 9162/13-11-14
Explosion protection
Global (IECEx)
Gas and dust IECEx FMG 10.0020X IECEx FMG 10.0020X
Ex nAc nCc [ia] IIC T4 Ta = - 20 ... + 70 °C
[Ex iaD]
Ex nAc nCc [ia] IIC T4 Ta = - 20 ... + 70 °C
[Ex iaD]
Europe (ATEX)
Gas and dust FM 06 ATEX 0008 X FM 06 ATEX 0008 X
E II 3 (1) G Ex nAc nCc [ia] IIC T4
E II (1) D [Ex ia] IIIC
E II 3 (1) G Ex nAc nCc [ia] IIC T4
E II (1) D [Ex ia] IIIC
Certifications and certificates
Certificates IECEx, ATEX, India (PESO), Canada (cFM),
Kazakhstan (GOST K), Korea (KTL),
Russia (GOST R), Serbia (SRPS), USA (FM),
Belarus (operating authorisation)
IECEx, ATEX, Canada (cFM),
Russia (GOST R), Serbia (SRPS), USA (FM),
Belarus (operating authorisation)
Ship approval DNV DNV
26 Isolators 2013-09-10·KP00·III·en
29. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Transmitter Supply Unit with Limit Contact
Field Circuit Ex i
Series 9162
Technical Data
Version 9162/13-11-12 9162/13-11-14
Safety data
Max. voltage Uo 27 V 27 V
Max. current Io 87.9 mA 87.9 mA
Max. power Po 574 mW 574 mW
Auxiliary power
Nominal voltage UN 24 V DC 24 V DC
Nominal current at
83 mA 83 mA
UN, 20 mA
Output
Output signal 0/4 ... 20 mA with HART 4 ... 20 mA with HART
Load resistance RL 0 ... 600 Ω (terminal 1+ / 2-) 0 ... 600 Ω (terminal 1+ / 2-)
Limiting values
Configuration using ISpac Wizard using ISpac Wizard
Message 2 NO / NC 2 NO / NC
Switching voltage ( ± 30 V ( ± 30 V
Switching current
( 100 mA ( 100 mA
(resistive load)
Error detection Ex i input
Message of line fault and
auxiliary power failure
- contact (30 V / 100 mA) closed to earth in case of error
- pac-Bus, potential-free contact (30 V / 100 mA)
2013-09-10·KP00·III·en Isolators 27
30. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Isolating Repeater Input
Series 9163 Rev. B
Series 9163 Rev. B A3
15281E00
WebCode 9163A
> Suitable for 4-wire HART transmitters
and voltage sources
> Intrinsically safe input [Ex ia] IIC
> Galvanic Isolation between input,
output and power supply
> Open-circuit and short-circuit monitoring and
messaging (can be switched off)
> For use up to SIL 2 (IEC 61508)
ATEX / IECEx
Zone 0 1 2 20 21 22
Ex i interface x x x x x x
Installation in x*) x*)
*) Restrictions see table explosion protection
Variants with UL/FM approval for NEC on request
Selection Table
Version Channels Input Output LFD* Order number Art. no. PS
Isolating repeater
1 0/4 ... 20 mA
0/4 ... 20 mA
no 9163/13-11-10s 214914 21
input
with HART
with HART
Series 9163
passive (sink) no 9163/13-10-10s 214912 21
0/1 ... 5 V,
0/2 ... 10 V
0/4 ... 20 mA no 9163/11-81-10s 214910 21
2 0/4 ... 20 mA
with HART
0/4 ... 20 mA
with HART
no 9163/23-11-10s 214920 21
passive (sink) no 9163/23-10-10s 214918 21
Note The order numbers listed in the table are for devices equipped with screw-type terminals.
For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with
"k" for spring-type terminals.
* LFD - line fault diagnosis,
no - The device transmits a line fault detected in the field circuit via the 4 ... 20 mA signal.
Without LED / relay contact.
28 Isolators 2013-09-10·KP00·III·en
31. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Isolating Repeater Input
Series 9163 Rev. B
Technical Data
Version 9163/.3-1.-1.. 9163/11-81-10.
Explosion protection
Global (IECEx)
Gas and dust
IECEx BVS 08.0050X IECEx BVS 08.0050X
Ex nA [ia Ga] IIC T4 Gc Ex nA [ia Ga] IIC T4 Gc
[Ex ia Da] IIIC [Ex ia Da] IIIC
[Ex ia Ma] I [Ex ia Ma] I
Europe (ATEX)
Gas and dust DMT 03 ATEX E010X DMT 03 ATEX E010X
E II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
E II (1) D [Ex ia Da] IIIC
[Ex ia Ma] I
E II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
E II (1) D [Ex ia Da] IIIC
[Ex ia Ma] I
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO),
Russia (GOST R), Serbia (SRPS),
Ukraine (TR)
IECEx, ATEX
Safety data
Max. voltage Ui 30 V 30 V
Max. current Ii 150 mA negligible
Max. power Pi 1000 mW negligible
Max. voltage Uo negligible 4.2 V
Max. current Io negligible negligible
Max. power Po – – negligible
Auxiliary power
Nominal voltage UN 24 V DC 24 V DC
Nominal current at
UN, 20 mA
1 channel 80 mA 80 mA
2 channels 135 mA – –
Input signal 0/4 ... 20 mA with HART 0 ... 5 V resp. 0 ... 10 V
Output
Output signal 9163/.3-11-10.: 0/4 ... 20 mA with HART
9163/.3-10-10.: passive (sink)
0/4 ... 20 mA
Load resistance RL 0 ... 600 Ω (terminal 1+/2- resp. 5+/6-)
0 ... 479 Ω (terminal 3+/2- resp. 4+/6-)
(with internal 221 Ω resistor for HART)
0 ... 600 Ω (terminal 1+/2- resp. 5+/6-)
2013-09-10·KP00·III·en Isolators 29
32. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
mA - Isolating Repeater
Series 9164
Series 9164 A3
08580E00
WebCode 9164A
> Interconnection of mA-sources and
active 2-wire inputs is possible
> Perfect solution to integrate 4-wire
transmitters with 2 wire I/O-cards
> Instrinsically safe input (Ex i) or
increased safety protection Ex e version
> Bidirectional HART transmission 4 ... 20 mA
> Galvanic isolation between input and output
ATEX NEC 505 NEC 506 NEC 500
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x x
Installation in x*) x*) x*) Installation in x*) x*) x*) Installation in x*) x*) x*)
*) Restrictions see table explosion protection
Class I Class I Class II Class III
Selection Table
Version Channels Input Output Order number Art. no. PS
mA - Isolating
1 Ex i: 4 ... 20 mA HART
Ex i: passive HART
9164/13-20-06 224365 21
repeater
(sink)
(sink)
Series 9164
Ex e: 4 ... 20 mA
HART (sink)
Ex i: passive HART
(sink)
9164/13-20-08 224364 21
Technical Data
Version 9164/13-20-06 (Ex e Input) 9164/13-20-08 (Ex i Input)
Explosion protection
Europe (ATEX)
Gas and dust KEMA 04 ATEX 1236 X KEMA 04 ATEX 1298
E II 2 (1) G Ex e mb [ia Ga] IIC T4 Gb
E II (1) D Ex e mb [ia Da] IIIC
E II 2 (1) G Ex ia [ia Ga] IIC T4 Gb
E II (1) D [Ex ia Da] IIIC
Certificates and approvals
Certificates ATEX ATEX
Ship approval DNV DNV
Safety data
Input 4-wire transmitter-side
Ex e connection
Nominal voltage Un: 30 V
Nominal current In: 30 mA
Nominal power Pn: 900 mW
4-wire transmitter-side
Ex i connection
Output parameters: Uo, Io, Po = 0
Max. voltage Ui: 30 V
Max. current Ii: 150 mA
Max. power Pi: 1 W
Output 2-wire output
Output parameters: Uo, Io, Po = 0
Max. voltage Ui: 30 V
Max. current Ii: 150 mA
Max. power Pi: 1 W
2-wire output
Output parameters: Uo, Io, Po = 0
Max. voltage Ui: 30 V
Max. current Ii: 150 mA
Max. power Pi: 1 W
Auxiliary power without without
Ex i / Ex e Input
Version passive (current sink) passive (current sink)
Input signal 3.8 ... 20.5 mA with / wihout HART 3.8 ... 20.5 mA with / wihout HART
Ex i output
Version passive (current sink) passive (current sink)
Output signal 3.6 ... 21 mA with HART 3.6 ... 21 mA with HART
30 Isolators 2013-09-10·KP00·III·en
33. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
mA - Isolating Repeater
Series 9164
Dimensional Drawings (All Dimensions in mm / inches) - Subject to Alterations
09432E00
10 mm / 4.0" 3 6
72 mm / 2.83 " 12 mm / 0.47 "
2013-09-10·KP00·III·en Isolators 31
34. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Isolating Repeater
Field Circuit Ex i
Series 9165
Series 9165 A3
09734E00
WebCode 9165A
> For intrinsically safe operation of
(HART)-control valves, i/p transmitters,
displays
> For HART output signals 0/4 ... 20 mA
> Intrinsically safe output [Ex ia] IIC
> Galvanic isolation between input,
output and power supply
> Open circuit / short-circuit monitoring and
messaging (can be switched off)
> For use up to SIL 2 (IEC 61508)
ATEX / IECEx NEC 505 NEC 506 NEC 500
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x x
Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)
*) Restrictions see table explosion protection:
Class I Class I Class II Class III
Selection Table
Version Channels Input Ex i output signal LFD relay Order number Art. no. PS
Isolating Repeater
1 0/4 ... 20 mA
0/4 ... 20 mA
yes 9165/16-11-11s 201270 21
Field Circuit Ex i
with HART
with HART
Series 9165
no 9165/16-11-10s 207909 21
2 0/4 ... 20 mA
with HART
0/4 ... 20 mA
with HART
yes 9165/26-11-11s 201272 21
no 9165/26-11-10s 207910 21
Note The order numbers listed in the table are for devices equipped with screw-type terminals.
For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with
"k" for spring-type terminals.
LFD - Line fault diagnostic
no - device transmits field-side line fault via 4 ... 20 mA signal via LED
yes - device transmits field-side line fault via 4 ... 20 mA signal via LED and relay contact
32 Isolators 2013-09-10·KP00·III·en
35. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Isolating Repeater
Field Circuit Ex i
Series 9165
Technical Data
Global (IECEx)
Gas and dust IECEx BVS 10.0011X
Ex nA nC [ia Ga] IIC T4 Gc
[Ex ia Da] IIIC
Europe (ATEX)
Gas and dust DMT 03 ATEX E 012 X
E II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc
E II (1) D [Ex ia Da] IIIC
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO), Canada (CSA), Kazakhstan (GOST K),
Korea (KCs) only for 9165/16-11-11., Russia (GOST R), Serbia (SRPS), Ukraine (TR),
USA (FM, UL*), Belarus (operating authorisation)
* for UL approval - special version on request
Ship approval DNV
Safety data
Max. voltage Uo 25.6 V
Max. current Io 96 mA
Max. power Po 605 mW
Auxiliary power
Nominal voltage UN 24 V DC
Nominal current at
UN, 20 mA
1 channel 55 mA
2 channels 90 mA
Input signal 0/4 ... 20 mA with HART
Ex i output
Output signal 0/4 ... 20 mA with HART
Connectable load
0 ... 800 Ω
resistance
Fault detection Ex i output
Signalization of faulty line
and power supply failure
- Contact (30 V / 100 mA) closed to ground in case of fault
- pac-Bus, floating contact (30 V / 100 mA)
(only for 9165/.6-11-11.)
2013-09-10·KP00·III·en Isolators 33
36. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Isolating Repeater Loop Powered
Field Circuit Ex i
Series 9167
Series 9167 A3
08577E00
WebCode 9167A
> For intrinsically safe operation of
(HART)-control valves, i/p transmitters,
displays, fire and gas detectors
> For HART output signals 0/4 ... 20 mA
> Intrinsically safe output [Ex ia] IIC
> Galvanic isolation between
inputs and outputs
> Without power supply
> Very low internal resistance
> HART communication signal transmitting,
bidirectionally
> For use up to SIL 3 (IEC 61508)
ATEX / IECEx NEC 505 NEC 506 NEC 500
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x x
Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)
*) Restrictions see table explosion protection
Class I Class I Class II Class III
Selection Table
Version Channels Ex i output Uo / Io / Po max. load resistance RL Order number Art. no. PS
Isolating Repeater
1 15.7 V / 60 mA / 233 mW 360 Ω 9167/11-11-00s 160238 21
Loop Powered Field
Circuit Ex i
Series 9167
25 V / 99 mA / 613 mW 800 Ω 9167/13-11-00s 160244 21
18.8 V / 107 mA / 503 mW 590 Ω 9167/14-11-00s 160250 21
2 15.7 V / 60 mA / 233 mW 360 Ω 9167/21-11-00s 160241 21
25 V / 99 mA / 613 mW 800 Ω 9167/23-11-00s 160247 21
18.8 V / 107 mA / 503 mW 590 Ω 9167/24-11-00s 160253 21
Note The order numbers listed in the table are for devices equipped with screw-type terminals.
For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with
"k" for spring-type terminals.
34 Isolators 2013-09-10·KP00·III·en
37. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Isolating Repeater Loop Powered
Field Circuit Ex i
Series 9167
Technical Data
Explosion protection
Global (IECEx)
Gas and dust IECEx BVS 11.0089X
Ex nA [ia Ga] IIC T4 Gc
[Ex ia Da] IIIC
Europe (ATEX)
Gas and dust BVS 04 ATEX E 082 X
E II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
E II (1) D [Ex ia Da] IIIC
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO), India (PESO), Canada (CSA), Kazakhstan (GOST K),
Korea (KCs) only for 9167/14-11-00, Russia (GOST R), Serbia (SRPS), Ukraine (TR),
USA (FM, UL), Belarus (operating authorisation)
Ship approval DNV
Safety data
Version 9167/.1-11-00, max. 360 Ω 9167/.3-11-00, max. 800 Ω 9167/.4-11-00, max. 590 Ω
Max. voltage Uo 15.7 V 25 V 18.8 V
Max. current Io 60 mA 99 mA 107 mA
Max. power Po 233 mW 613 mW 503 mW
Auxiliary power without without without
Input signal IE 0/4 ... 20 mA with HART 0/4 ... 20 mA with HART 0/4 ... 20 mA with HART
Ex i output
Output signal 0/4 ... 20 mA with HART 0/4 ... 20 mA with HART 0/4 ... 20 mA with HART
Function range 0 ... 40 mA 0 ... 40 mA 0 ... 40 mA
2013-09-10·KP00·III·en Isolators 35
38. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Switching Repeater
Field Circuit Ex i
Series 9170
Series 9170 A3
06528E00
WebCode 9170A
> For operation of contacts,
proximity sensors (NAMUR), optocouplers
> Intrinsically safe input [Ex ia] IIC
> Galvanic isolation between input,
output and auxiliary power
> Open-circuit / short-circuit monitoring and
messaging (can be switched off)
> Inversion of output signal can be adjusted
> Transmission frequency up to 10 kHz
> Can be used up to SIL 2 (relay output) or
SIL 3 (electronic output) (IEC 61508)
ATEX / IECEx NEC 505 NEC 506 NEC 500
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Ex i
x x x x x x Ex i
interface
Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)
*) Restrictions see table explosion protection
Class I Class I Class II Class III
interface
x x x Ex i
interface
x x x x x x
Selection Table
Output version
(control)
Channels Power supply Output / channel LFD relay LFT Order number Art. no. PS
Signal relay
(125 V / 1 A)
1 24 V DC 1 change-over contact no no 9170/11-11-13s 207471 21
2 change-over contacts yes no 9170/10-11-11s 160309 21
120 ... 230 V AC 2 change-over contacts yes no 9170/10-11-21s 160318 21
2 24 V DC 1 change-over contact yes no 9170/20-10-11s 160290 21
2 NO yes no 9170/20-11-11s 160287 21
no no 9170/21-11-13s 207472 21
120 ... 230 V AC 1 change-over contact yes no 9170/20-10-21s 160300 21
2 NO yes no 9170/20-11-21s 160303 21
Power relay
(250 V / 4 A)
1 24 V DC 1 change-over contact yes no 9170/10-12-11s 160312 21
120 ... 230 V AC 1 change-over contact yes no 9170/10-12-21s 160321 21
2 change-over contacts yes no 9170/10-13-21s 160327 21
2 24 V DC 1 change-over contact yes no 9170/20-12-11s 160293 21
120 ... 230 V AC 1 change-over contact yes no 9170/20-12-21s 160306 21
Electronic
(35 V / 50 mA)
1 24 V DC 1 electronic output yes no 9170/11-14-11s 203287 21
yes 9170/11-14-12s 203288 21
2 24 V DC 1 electronic output yes no 9170/21-14-11s 203152 21
yes 9170/21-14-12s 203153 21
Note The order numbers listed in the table are for devices equipped with screw-type terminals.
For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with
"k" for spring-type terminals.
LFD - Line fault diagnostic
no - device transmits line fault via LED
yes - device transmits line fault via LED and relay contact
LFT - line fault transparency, device signals line fault on field side to the control directly via the signal output.
36 Isolators 2013-09-10·KP00·III·en
39. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Switching Repeater
Field Circuit Ex i
Series 9170
Technical Data
Version 24 V DC
9170/.0-11-11.,
9170/20-10-11.
24 V DC
9170/.1-11-13.,
9170/.1-11-14.,
9170/.1-14-12.
24 V DC
9170/.0-12-11.
Explosion protection
Global (IECEx)
Gas IECEx BVS 09.0041X IECEx BVS 09.0041X IECEx BVS 09.0041X
Ex nAc nCc [ia] IIC T4, [Ex ia] IIIC Ex nAc nCc [ia] IIC T4, [Ex ia] IIIC [Ex ia] IIC, [Ex ia] IIIC
Europe (ATEX)
Gas and dust DMT 02 ATEX E195X DMT 02 ATEX E195X DMT 02 ATEX E195X
E II 3 (1) G Ex nAc nCc [ia] IIC T4
E II (1) D [Ex ia] IIIC
E II 3 (1) G Ex nAc nCc [ia] IIC T4
E II (1) D [Ex ia] IIIC
E II (1) G [Ex ia] IIC
E II (1) D [Ex ia] IIIC
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO),
India (PESO), Canada (CSA),
Kazakhstan (GOST K),
Russia (GOST R), Ukraine (TR),
USA (FM, UL),
Belarus (operating authorisation)
IECEx, ATEX, India (PESO),
Canada (CSA),
Kazakhstan (GOST K),
Russia (GOST R), USA (FM),
Belarus (operating authorisation)
IECEx, ATEX, Brazil (INMETRO),
India (PESO), Canada (CSA),
Kazakhstan (GOST K),
Russia (GOST R), Serbia (SRPS),
Ukraine (TR), USA (FM, UL),
Belarus (operating authorisation)
Ship approval DNV DNV DNV
Further parameters
Installation in Zone 2, Div. 2 and
in the safe area
in Zone 2, Div. 2 and
in the safe area
in safe area
Further information see respective certificate and
operating instructions
see respective certificate and
operating instructions
see respective certificate and
operating instructions
Version 120 ... 230 V AC
9170/.0-11-21.,
9170/20-10-21.
120 ... 230 V AC
9170/.0-12-21.,
9170/.0-13-21.
Explosion protection
Global (IECEx)
Gas IECEx BVS 09.0041X IECEx BVS 09.0041X
[Ex ia] IIC, [Ex ia] IIIC [Ex ia] IIC, [Ex ia] IIIC
Europe (ATEX)
Gas and dust DMT 02 ATEX E195X DMT 02 ATEX E195X
E II (1) G [Ex ia] IIC
E II (1) D [Ex ia] IIIC
E II (1) G [Ex ia] IIC
E II (1) D [Ex ia] IIIC
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO), India (PESO),
Canada (CSA), Kazakhstan (GOST K),
Russia (GOST R), Serbia (SRPS), Ukraine (TR),
USA (FM, UL), Belarus (operating authorisation)
IECEx, ATEX, Brazil (INMETRO), India (PESO),
Canada (CSA), Kazakhstan (GOST K), Korea (KCs)
only for 9170/10-12-21., Russia (GOST R),
Serbia (SRPS), USA (FM, UL),
Belarus (operating authorisation)
Ship approval DNV DNV
Further parameters
Installation in safe area in safe area
Further information see respective certificate and operating instructions see respective certificate and operating instructions
Safety data
Version 9170/10-..-..
(1 channel)
9170/11-..-..
(1 channel)
9170/20-..-..
(2 channels)
9170/21-..-..
(2 channels)
Inputs (channels individually)
Max. voltage Uo 10.6 V 9.6 V 10.6 V 9.6 V
Max. current Io 24 mA 10 mA 24 mA 10 mA
Max. power Po 64 mW 24 mW 64 mW 24 mW
Inputs (2 channels parallel)
Max. voltage Uo – – – – 10.6 V 9.6 V
Max. current Io – – – – 48 mA 20 mA
Max. power Po – – – – 128 mW 48 mW
Version 24 V DC
9170/..-1.-1.
120 ... 230 V AC
9170/.0-1.-21.
Auxiliary power
Nominal voltage UN 24 V DC 120 ... 230 V AC
Input signal acc. to EN 60947-5-6 (NAMUR) acc. to EN 60947-5-6 (NAMUR)
Output see selection table see selection table
Error detection Ex i input
Message of line fault and
auxiliary power failure
- Contact in the output circuit (35 V / 50 mA) opens in
case of fault (only at 9170/.1-14-12.)
- contact (30 V / 100 mA), closed to ground in
case of fault *)
- pac-Bus, floating contact (30 V / 100 mA) *)
*) not at 9170/.1-11-13.
none
2013-09-10·KP00·III·en Isolators 37
40. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
I.S. Relay Module
Series 9172
Series 9172 A3
08578E00
WebCode 9172A
> For binary signal and control circuits
> Intrinsically safe inputs or outputs [Ex ia] IIC
> Galvanic isolation between
inputs and outputs
> For use up to SIL 2 (IEC 61508)
ATEX / IECEx NEC 505 NEC 506 NEC 500
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x x
Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)
*) For restrictions, see Explosion Protection table
Class I Class I Class II Class III
Selection Table
Version Channels Input Output / channel Order number Art. no. PS
I.S. relay module
1 Ex i signal 1 change over contact
9172/10-11-00s 160359 21
Series 9172
(250 V / 4 A)
Ex i / I.S., 1 change over contact
(125 V / 4 A, 30 V / 4 A)
9172/12-11-00s 169651 21
Non-Ex i signal Ex i / I.S., 1 change over contact
(125 V / 4 A, 30 V / 4 A)
9172/11-11-00s 160366 21
2 Ex i signal 1 change over contact
(250 V / 4 A)
9172/20-11-00s 160363 21
Ex i / I.S., 1 change over contact
(125 V / 4 A, 30 V / 4 A)
9172/22-11-00s 169653 21
Non-Ex i signal Ex i / I.S., 1 change over contact
(125 V / 4 A, 30 V / 4 A)
9172/21-11-00s 160369 21
Note The order numbers listed in the table are for devices equipped with screw-type terminals.
For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with
"k" for spring-type terminals.
Technical Data
Explosion protection
Global (IECEx)
Gas and dust IECEx BVS 09.0002X
Ex nA nC [ia Ga] IIC T4 Gc
[Ex ia Da] IIIC
Europe (ATEX)
Gas and dust BVS 04 ATEX E 097 X
E II 3 (1) G Ex nA nC [ia] IIC T4
E II (1) D [Ex iaD]
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO), India (PESO), Canada (cFM), Kazakhstan (GOST K),
Russia (GOST R), Serbia (SRPS), Ukraine (TR), USA (FM, UL), Belarus (operating authorisation)
Ship approval DNV
38 Isolators 2013-09-10·KP00·III·en
41. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
I.S. Relay Module
Series 9172
Technical Data
Safety data
Version 9172/.0-11-00 9172/.1-11-00 9172/.2-11-00
Inputs
Max. voltage Ui 30 V – – 30 V
Max. current Ii 150 mA – – 150 mA
Max. power Pi 1.3 W – – 1.3 W
Outputs (contact) – –
for connection of intrinsically safe circuits with:
max. voltage Ui
125 V AC
125 V DC
max. current Ii
4 A
0.25 A
Internal capacitance Ci negligible negligible negligible
Internal inductance Li negligible negligible negligible
Isolation voltage 253 V AC 253 V AC 253 V AC
60 V DC
0.3 A
30 V DC
4 A
Further parameters
Version 9172/.0-11-00 9172/.1-11-00 9172/.2-11-00
Installation in Zone 2, Div. 2 and
in the safe area *)
in Zone 2, Div. 2 and
in the safe area
in Zone 2, Div. 2 and
in the safe area *)
*) in Zone 2 max. contact load
capacity 125 V / 4 A
– – *) in Zone 2 max. contact load
capacity 125 V / 4 A
Further information see respective certificate and
operating instructions
see respective certificate and
operating instructions
see respective certificate and
operating instructions
Auxiliary power
Supply without without without
Max. power losses per
0.4 W 0.4 W 0.4 W
channel
Input
Input signal Ex i non-Ex i Ex i
Switching signal 12 ... 30 V 12 ... 31.2 V 12 ... 30 V
Current consumption < 16 mA at 12 V
< 11 mA at 24 ... 30 V
< 16 mA at 12 V
< 11 mA at 24 ... 31.2 V
< 16 mA at 12 V
< 11 mA at 24 ... 30 V
Output see Selection Table see Selection Table see Selection Table
Accessories and Spare Parts
Designation Description Art. no. PS Weight
kg
Relay modules for
installation in Zone 1
The modules 8510/122-06-6..-00 contain relay modules of Series 9172.
If 8510 modules are installed in an enclosure of the degree of protection Ex e
(e.g. Type 8150 or 8146), installation in Zone 1 is possible.
165514 19 1.470
165531 19 1.470
200381 19 1.470
220076 19 1.470
Relay modules Type 9172 Modules Type 8510
9172/10-11-00s 8510/122-06-600-00
9172/20-11-00s 8510/122-06-601-00
9172/21-11-00s 8510/122-06-602-00
9172/22-11-00s 8510/122-06-604-00
2013-09-10·KP00·III·en Isolators 39
42. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Electronic Relay
Series 9174
Series 9174 A3
02133E00
WebCode 9174A
> Ex i control for switching Ex e loads
> Maintenance-free and electronic switching
> Compact design (width 12 mm)
> Installation in Zone 1 together with I/O IS1 or
FF Digital I/O coupler Series 9413
> Galvanic isolation between input and output
ATEX
Zone 0 1 2 20 21 22
Ex i interface x x x x
For use in x x x x
Selection Table
Version Channels Input Output Order number Art. no. PS Weight
kg
Electronic relay
Series 9174
1 Ex i Ex e, 48 V DC, 2 A 9174/10-14-00 212340 29 0.110
Ex e, 250 V UC, 1 A 9174/10-15-00 212431 29 0.110
Technical Data
Explosion protection
Europe (ATEX)
Gas and dust applied for
EII 2 G Ex e mb [ib Gb] IIC T4 Gb
E II (2) D [Ex ib Db] IIIC
Version 9174/10-14-10 9174/10-15-10
Safety data
Max. voltage Ui 28 V 28 V
Max. current Li 150 mA 150 mA
Max. power Pi 780 mW 780 mW
Internal capacitance Ci negligible negligible
Internal inductance Li negligible negligible
Isolation voltage 253 V 253 V
Rated operational current
Ex e back-up fuse 2 A 3.15 A
Max. power dissipation 0.85 W 1.6 W
Ex i input
Switching level for
ON / OFF
ON 11 ... 28 V 11 ... 28 V
OFF 0 ... 5 V 0 ... 5 V
Control current < 15 mA < 15 mA
Ex e output
Max. voltage 48 V DC 250 V AC / DC
Max. current 2 A 1 A
Min. voltage 5 V DC 90 V AC / 40 V DC
Min. current 2 mA 10 mA
Max. switching frequency 300 Hz 300 Hz
40 Isolators 2013-09-10·KP00·III·en
43. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Electronic Relay
Series 9174
Dimensional Drawings (All Dimensions in mm / inch) - Subject to Alterations
14836E00
108,8 mm / 4.28 "
101,5 mm / 3.99 "
90 mm / 3.54 "
7,5 mm / 0.29 "
92 mm / 3.62 "
79 mm / 3.11 " 12,2 mm / 0.48 "
2013-09-10·KP00·III·en Isolators 41
44. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Binary Output
Series 9175
Series 9175 A3
09822E00
WebCode 9175A
> For intrinsically safe operation of
I.S. solenoid valves and indicators
> Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC
> Galvanic isolation between input,
output and power supply
> Open-circuit and short-circuit monitoring
(can be switched off)
> For use up to SIL 3 (IEC 61508)
ATEX / IECEx NEC 505 NEC 506 NEC 500
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Ex i
x x x x x x Ex i
interface
Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)
*) Restrictions see table explosion protection
Class I Class I Class II Class III
interface
x x x Ex i
interface
x x x x x x
Selection Table
Version Channels No-load
voltage Uout
Max. output
current Iout max
Internal
resistance Ri
Order number Art. no. PS
Binary output
Series 9175
1 10 V 60 mA 150 Ω 9175/10-12-11s 160398 21
17.5 V 45 mA 130 Ω 9175/10-14-11s 160410 21
25 V 35 mA 250 Ω 9175/10-16-11s 160416 21
2 10 V 60 mA / 120 mA *) 150 Ω / 75 Ω *) 9175/20-12-11s 160404 21
17.5 V 45 mA / 90 mA *) 130 Ω / 65 Ω *) 9175/20-14-11s 160413 21
25 V 35 mA / 70 mA *) 250 Ω / 125 Ω *) 9175/20-16-11s 160419 21
*) Parallel connection of the outputs possible; thus, doubling of the output current.
Note The order numbers listed in the table are for devices equipped with screw-type terminals.
For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with
"k" for spring-type terminals.
42 Isolators 2013-09-10·KP00·III·en
45. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Binary Output
Series 9175
Technical Data
Explosion protection
Global (IECEx)
Gas IECEx BVS 10.0050X
Ex nAc nCc [ia] IIC T4
[Ex ia] IIIC
Europe (ATEX)
Gas and dust DMT 03 ATEX E 043 X
E II 3 (1) G Ex nA nC [ia] IIC T4
E II (1) D [Ex iaD]
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO), India (PESO), Canada (CSA), Kazakhstan (GOST K),
Russia (GOST R), Ukraine (TR), USA (FM, UL), Belarus (operating authorisation)
Ship approval DNV
Safety data
Version 9175/.0-12-11. 9175/.0-14-11. 9175/.0-16-11.
Max. values per output
Max. voltage Uo 11.3 V 19.6 V 11.3 V
Max. current Io 75 mA 150 / 60 mA 110 / 50 mA
Max. power Po 210 mW 732 mW 760 mW
Auxiliary power
Nominal voltage UN 24 V DC
Nominal current
(at UN, Iout max)
80 mA / 140 mA
Input
Voltage for ON / OFF
ON 15 ... 31.2 V
OFF 0 ... 5 V
Control circuit < 5 mA
Ex i output see selection table
Fault detection Ex i output
Signalization of faulty line
and power supply failure
- Contact (30 V / 100 mA) closed to ground in case of fault
- pac-Bus, floating contact (30 V / 100 mA)
2013-09-10·KP00·III·en Isolators 43
46. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Binary Output with Line Fault Transparency
Series 9175
Series 9175 A3
07439E00
WebCode 9175A
> For intrinsically safe operation of
I.S. solenoid valves and indicators
> Intrinsically safe output [Ex ia] IIC
> Line fault transparency (LFT):
line fault signalling directly via output on
PLC / DCS
> For use up to SIL 2 (IEC 61508)
ATEX / IECEx
Zone 0 1 2 20 21 22
Ex i interface x x x x x x
Installation in x x
Selection Table
Version Channels No-load voltage
Uout
Max. output
current Iout max
Internal
resistance Ri
Order number Art. no. PS
Binary output
with line fault
transparency
Series 9175
1 10 V 60 mA 150 Ω 9175/10-12-12s 168456 21
17.5 V 45 mA 130 Ω 9175/10-14-12s 168458 21
25 V 35 mA 250 Ω 9175/10-16-12s 168460 21
Note The order numbers listed in the table are for devices equipped with screw-type terminals.
For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with
"k" for spring-type terminals.
44 Isolators 2013-09-10·KP00·III·en
47. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Binary Output with Line Fault Transparency
Series 9175
Technical Data
Explosion protection
Global (IECEx)
Gas IECEx BVS 10.0050X
Ex nAc nCc [ia] IIC T4
[Ex ia] IIIC
Europe (ATEX)
Gas and dust DMT 03 ATEX E 043 X
E II 3 (1) G Ex nA nC [ia] IIC T4
E II (1) D [Ex iaD]
Certifications and certificates
Certificates IECEx, ATEX, India (PESO), Kazakhstan (GOST K), Russia (GOST R), Ukraine (TR),
Belarus (operating authorisation)
Ship approval DNV
Max. values per output
Version 9175/.0-16-12. 9175/.0-14-12. 9175/.0-12-12.
Max. voltage Uo 11.3 V 19.6 V 11.3 V
Max. current Io 110 / 50 mA 150 / 60 mA 75 mA
Max. power Po 760 mW 732 mW 210 mW
Auxiliary power
Nominal voltage UN 24 V DC 24 V DC 24 V DC
Current consumption
Device draws its power from auxiliary power or signal cable as a function of its switching state.
Version 9175/.0-16-12. 9175/.0-14-12. 9175/.0-12-12.
Switching state Input = Output Input = Output Input = Output
Switching state OFF
Auxiliary power rated
current IN
40 mA 35 mA 30 mA
Switching state ON
Auxiliary power rated
current IN
14 mA 14 mA 14 mA
Signal input rated
current IN
90 mA 80 mA 50 mA
Power consumption 2.5 W 2.26 W 1.5 W
Power loss 1.92 W 1.73 W 1.4 W
Input
Voltage for ON / OFF
ON 15 ... 31.2 V
OFF 0 ... 5 V
Control circuit < 5 mA
Ex i output see selection table
Fault detection Ex i output
Signalization of faulty line
and power supply failure
- contact on the signal input open in case of fault
- pac-Bus, floating contact (30 V / 100 mA)
2013-09-10·KP00·III·en Isolators 45
48. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Binary Output without Power Supply
Series 9176
Series 9176 A3
10495E00
WebCode 9176A
> For intrinsically safe operation of
Ex i solenoid valves, indicators and horns
> Power supply by control circuit, loop powered
> Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC
> Galvanic isolation
between inputs and outputs
> For use up to SIL 3 (IEC 61508)
ATEX NEC 505 NEC 506 NEC 500
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Ex i
x x x x x x Ex i
interface
Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)
*) Restrictions see table explosion protection
Class I Class I Class II Class III
interface
x x x Ex i
interface
x x x x x x
Selection Table
Version Channels No-load voltage
Uout
Max. output
current Iout max
Internal
resistance Ri
Order number Art. no. PS
Binary output
without power supply
Series 9176
1 10 V 60 mA 150 Ω 9176/10-12-00s 160452 21
17.5 V 45 mA 130 Ω 9176/10-14-00s 160459 21
25 V 29 mA 320 Ω 9176/10-15-00s 160472 21
35 mA 250 Ω 9176/10-16-00s 160465 21
43 mA 460 Ω 9176/10-17-00s 200546 21
2 10 V 60 mA / 120 mA *) 150 Ω / 75 Ω *) 9176/20-12-00s 160456 21
17.5 V 45 mA / 90 mA *) 130 Ω / 65 Ω *) 9176/20-14-00s 160462 21
25 V 29 mA / 58 mA *) 320 Ω / 160 Ω *) 9176/20-15-00s 165567 21
35 mA / 70 mA *) 250 Ω / 125 Ω *) 9176/20-16-00s 160468 21
43 mA / 86 mA *) 460 Ω / 230 Ω *) 9176/20-17-00s 171425 21
*) Parallel connection of the outputs possible. Doubling of the output current.
Note The order numbers listed in the table are for devices equipped with screw-type terminals.
For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with
"k" for spring-type terminals.
46 Isolators 2013-09-10·KP00·III·en
49. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Binary Output without Power Supply
Series 9176
Technical Data
Explosion protection
Europe (ATEX)
Gas and dust BVS 04 ATEX E 075 X
E II 3 (1) G Ex nA [ia] IIC T4
E II (1) D [Ex iaD]
Certifications and certificates
Certificates ATEX, Brazil (INMETRO), India (PESO), Canada (cFM), Kazakhstan (GOST K),
Russia (GOST R), Ukraine (TR), USA (FM), USA (UL) - not for type 9176/..-17-00,
Belarus (operating authorisation)
Ship approval DNV
Safety data
Version 9176/..-12-... 9176/..-14-... 9176/..-15-... 9176/..-16-... 9176/..-17-...
Max. values per output
Max. voltage Uo 11.3 V 19.6 V 27.6 V 27.6 V 27.6 V
Max. current Io
[Ex ia] 75 mA 150 mA 86.5 mA 110 mA 60 mA
[Ex ib] – – 60 mA 44 mA 50 mA – –
Max. power Po 210 mW 732 mW 596 mW 760 mW 415 mW
Auxiliary power without
Input
Voltage for ON / OFF
ON 18 ... 31.2 V
OFF 0 ... 5 V
Ex i output see selection table
2013-09-10·KP00·III·en Isolators 47
50. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Resistance Isolator
Series 9180
Series 9180 A3
11026E00
WebCode 9180A
> For intrinsically safe operartion of resistance
thermometers or other resistance sensors
> World-wide unique dual channel solution
– space saving, only 8.8 mm per channel
> For 2-, 3- and 4-wire circuits
> Resistance range from
18 ... 391 Ω or 180 ... 3910 Ω
> Intrinsically safe input [Ex ia] IIC
> Galvanic isolation between input,
output and power supply
ATEX / IECEx NEC 505 NEC 506 NEC 500
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x x
Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)
*) Restrictions see table explosion protection
Class I Class I Class II Class III
Selection Table
Version Channels Measuring range Order number Art. no. PS
Resistance isolator
1 18 ... 391 Ω (Pt100) 9180/10-77-11s 160491 21
Series 9180
180 ... 3910 Ω (Pt1000) 9180/11-77-11s 160499 21
2 18 ... 391 Ω (Pt100) 9180/20-77-11s 160494 21
180 ... 3910 Ω (Pt1000) 9180/21-77-11s 160502 21
Note The order numbers listed in the table are for devices equipped with screw-type terminals.
For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with
"k" for spring-type terminals.
Technical Data
Explosion protection
Global (IECEx)
Gas and dust IECEx BVS 10.0055X
Ex nAc nCc [ia] IIC T4
[Ex ia] IIIC
Europe (ATEX)
Gas and dust BVS 05 ATEX E 176 X
E II 3 (1) G Ex nAc nCc [ia] IIC T4
E II (1) D [Ex ia] IIIC
Certifications and certificates
Version 9180/.0 9180/.1
Certificates IECEx, ATEX, Brazil (INMETRO),
India (PESO), Kazakhstan (GOST K),
Korea (KCs) only for 9180/10-77-11.,
Russia (GOST R), USA (FM),
Belarus (operating authorisation)
IECEx, ATEX, Brazil (INMETRO),
India (PESO), Kazakhstan (GOST K),
Russia (GOST R), USA (FM),
Belarus (operating authorisation)
Ship approval DNV DNV
48 Isolators 2013-09-10·KP00·III·en
51. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Resistance Isolator
Series 9180
Technical Data
Version 9180/.0 9180/.1
Safety data
Max. voltage Uo 6.5 V 6.5 V
Max. current Io 16.5 mA 16.5 mA
Max. power Po 27 mW 27 mW
Ex i input
Connection type (no. of wires) 2-, 3-, 4-wire circuits 2-, 3-, 4-wire circuits
Measuring range 18 ... 391 Ω (Pt100) 180 ... 3910 Ω (Pt1000)
Middle resolution 10 m Ω 100 m Ω
Output
Output signal equals input signal (resistance)
Response time (10 ... 90 %)
< 10 ms
Multiplexer operation
Response time (Input = Output) < 1sec
Error detection Ex i input
Message of line fault and
auxiliary power failure
- contact (30 V / 100 mA) closed to earth in case of error
- pac-Bus, potential-free contact (30 V / 100 mA)
2013-09-10·KP00·III·en Isolators 49
52. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Temperature Transmitter
Field Circuit Ex i
Series 9182
Series 9182 A3
09746E00
WebCode 9182A
> For intrinsically safe operation of
thermocouples, resistance thermometers,
resistance transmitters, mV-sources
> One unit individually configurable for nearly
all temperature sensors
> Intrinsically safe input [Ex ia] IIC
> Galvanic isolation between input, output,
power supply and configuration interface
> Open-circuit and short-circuit monitoring and
messaging (can be switched off)
> Simple configuration with PC or DIP-switches
ATEX / IECEx NEC 505 NEC 506 NEC 500
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Ex i
x x x x x x Ex i
interface
Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)
*) Restrictions see table explosion protection
Class I Class I Class II Class III
interface
x x x Ex i
interface
x x x x x x
Selection Table
Version Channels Output Limit value contact
(per channel)
SIL Order number Art. no. PS
Temperature
transmitter
Series 9182,
field circuit Ex i
1 0/4 ... 20 mA
active / source
without – – 9182/10-51-11s 160546 21
2 9182/10-51-13s 201653 21
2 NO / NC – – 9182/10-51-12s 160549 21
2 9182/10-51-14s 201682 21
0/4 ... 20 mA
passive / sink
without 2 9182/10-59-13s 201657 21
2 0/4 ... 20 mA
active / source
without – – 9182/20-51-11s 160541 21
Note The order numbers listed in the table are for devices equipped with screw-type terminals.
For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with
"k" for spring-type terminals.
Signal duplication due to parallel connection of inputs of 9182/20-51-.. (dual channel).
Further information see operating instruction.
50 Isolators 2013-09-10·KP00·III·en
53. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Temperature Transmitter
Field Circuit Ex i
Series 9182
Technical Data
Explosion protection
Global (IECEx)
Gas IECEx BVS 09.0046X
Ex nAc nCc [ia] IIC T4
[Ex ia] IIIC
Europe (ATEX)
Gas and dust DMT 02 ATEX E 243 X
E II 3 (1) G Ex nAc nCc [ia] IIC T4
E II (1) D [Ex ia] IIIC
Certifications and certificates
Version 9182/.0-51-1. 9182/10-5.-13, SIL 2
9182/10-51-14, SIL 2
Certificates IECEx, ATEX, Brazil (INMETRO),
Canada (CSA), Kazakhstan (GOST K),
Korea (KTL) only for 9182/10-51-11,
Russia (GOST R), Ukraine (TR),
USA (FM, UL),
Belarus (operating authorisation)
IECEx, ATEX, Kazakhstan (GOST K),
Russia (GOST R), Ukraine (TR),
Belarus (operating athorisation)
Ship approval DNV DNV
Safety data
Max. voltage Uo 6.5 V
Max. current Io 19.7 mA
Max. power Po 32 mW (linear characteristic)
Auxiliary power
Nominal voltage UN 24 V DC
Nominal current at UN
1 channel 70 mA
2 channels 80 mA
Ex i Input The input parameters can be set via the parameterising software ISpac Wizard or
DIP switch (only type 9182/.0-5.-11.).
Input resistance thermometer
Types Pt 100, Pt 500, Pt 1000
Ni 100, Ni 500, Ni 1000
Type of circuit 2-, 3-, 4-wire circuit
Input thermocouple Types B, E, J, K, N, R, S, T, L, U, XK
Input resistance transmitter
up to 100 k Ω
(RTD)
Output
(only for 9182/.0-51-1.)
Output signal 0/4 ... 20 mA (configurable)
Connectable load
resistance RL
1 channel 0 ... 750 Ω
2 channels 0 ... 600 Ω
Limiting values
Message 2 NO / NC per channel
(configurable using ISpac Wizard)
Switching voltage ( ± 30 V
Switching current
(resistive load)
( 100 mA
Error detection Ex i input
Message of line fault and
auxiliary power failure
- contact (30 V / 100 mA) closed to earth in case of error
- pac-Bus, potential-free contact (30 V / 100 mA)
2013-09-10·KP00·III·en Isolators 51
54. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Fieldbus Isolating Repeater
Series 9185
Series 9185 A3
09812E00
WebCode 9185A
> For isolation between an intrinsically safe or
non-intrinsically safe RS 422 / RS 485 bus
and a non-intrinsically safe RS 232, RS 422,
RS 485 interface
> For operation of the intrinsically safe
Profibus DP (RS 485 IS to PNO standard)
> Intrinsically safe fieldbus RS 422, RS 485
[Ex ib] IIC
> Galvanic isolation between
RS 422 / RS 485 (Ex i), RS 232, RS 422,
RS 485 and power supply
> Transmission speed adjustable
between 1.2 kbit/s and 1.5 Mbit/s
> Automatic setting of transmission speed
for Profibus DP
> Bitrefresh
ATEX / IECEx NEC 505 NEC 506 NEC 500
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Ex i
x x x x Ex i
interface
Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)
*) Restrictions see table explosion protection
Class I Class I Class II Class III
interface
x x Ex i
interface
x x x x x x
Selection Table
Version Interfaces field area Interfaces safe area Order number Art. no. PS
Fieldbus isolating
RS-485 IS (PNO) RS-232, RS-422, RS-485 9185/11-35-10s 160587 21
repeater
Series 9185
RS-422, RS-485 RS-232, RS-422, RS-485 9185/12-45-10s 160594 21
Note The order numbers listed in the table are for devices equipped with screw-type terminals.
For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with
"k" for spring-type terminals.
52 Isolators 2013-09-10·KP00·III·en
55. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Fieldbus Isolating Repeater
Series 9185
Technical Data
Version 9185/11-35-10 9185/12-45-10
Explosion protection
Global (IECEx)
Gas and dust IECEx BVS 06.0004X IECEx BVS 06.0004X
Ex nAc [ib] IIC T4
[Ex ib] IIIC
Ex nAc IIC T4
Europe (ATEX)
Gas and dust DMT 02 ATEX E246X BVS 10 ATEX E 105 X
E II (2) GD [EEx ib] IIC/IIB,
E II 3 G EEx nA II T4
E II 3G Ex nAc IIC T4
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO),
India (PESO), Canada (CSA),
Kazakhstan (GOST K), Russia (GOST R),
Serbia (SRPS), Ukraine (TR), USA (FM),
Belarus (operating authorisation)
IECEx, ATEX, Brazil (INMETRO),
India (PESO), Canada (CSA),
Kazakhstan (GOST K), Russia (GOST R),
Serbia (SRPS), Ukraine (TR), USA (FM),
Belarus (operating authorisation)
Ship approval DNV, ABS, RS DNV, ABS, RS
Version 9185/11-35-10 9185/12-45-10
Safety data
Max. voltage Uo 3.73 V – –
Max. current Io 149 mA – –
Max. power Po 139 mW – –
For connection RS 485 IS
Insulation voltage 253 V – –
Internal capacity Ci and
negligible – –
inductivity Li
Max. permissible
voltage Ui
± 4.2 V – –
Auxiliary power
Nominal voltage UN 24 V UC 24 V UC
Nominal current (24 V) 80 mA 80 mA
Interface field area
Version RS 485 IS RS 485 / RS 422 (can be set)
Level setting: RS 485 IS (PNO specification) and RS
485 IS (R. STAHL specification)
EIA RS 485, EIA RS 422
Connections Sub-D socket X3, 9-pole Sub-D socket X3, 9-pole
Transfer speed 1.2 kbit/s ... 1.5 Мbit/s 1.2 kbit/s ... 1.5 Мbit/s
Settings fixes transmission speed or automatic detection
> 9.6 kbit/s (only with Profibus DP)
fixes transmission speed or automatic detection
> 9.6 kbit/s (only with Profibus DP)
Line length depends on transmission speed and cable depends on transmission speed and cable
Terminating resistor to be set in external plug to be set in external plug
Data transmission
LED green "RxD3" LED green "RxD3"
indication
Interface safe area
Version RS 232, RS 422 (from Rev. B), RS 485 RS 232, RS 485 / RS 422 (can be set)
Settings fixed transmission speed or automatic
detection > 9.6 kbit/s (only with Profibus DP)
fixed transmission speed or automatic
detection > 9.6 kbit/s (only with Profibus DP)
2013-09-10·KP00·III·en Isolators 53
56. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Fibre Optics Fieldbus Isolating Repeater
Series 9186
Series 9186 A3
08579E00
WebCode 9186A
> Easy installation and mainetance due to:
– Intrinsically safe optical interface
– Intrinsically safe bus connection via
RS-485 IS (PNO)
> High availability due to:
– Build-up of ring structures, redundant
Point-to-Point, line structures
– Integrated analysis of optical input signal
– Error message if critical levels of input
signal reached
> Transmission of Profibus DP, Modbus,
HART on RS-485, R. STAHL Servicebus
> 9186/12
– Installation in Zone 1 and Zone 2 possible
– Fieldbus interface for intrinsically safe
Profibus DP (PNO)
> 9186/.5
– Installation in Zone 2 possible
ATEX NEC 505 NEC 506 NEC 500
Zone 0 1 2 20 21 22 0 1 2 20 21 22 Division 1 2 1 2 1 2
9186/12-11-11:
x x x x x x x x x 9186/12-11-11:
Ex i interface
9186/.5-..-..:
Ex i interface
x x x 9186/.5-..-..:
9186/12-11-11:
Installation in
x*) x*) x*) x*) x*) x*) x*) 9186/12-11-11:
9186/.5-..-..:
Installation in
x*) x*) x*) x*) 9186/.5-..-..:
*) Restrictions see table explosion protection
Class I Class I Class II Class III
Ex i interface
x x x x x x
Ex i interface
x x x
Installation in
x*) x*) x*)
Installation in
x*) x*) x*)
Selection Table
Version Installation in Network structure Order number Art. no. PS
Fibre optics fieldbus
isolating repeater
Series 9186
Zone 1 Ring, point-to-point redundant, line 9186/12-11-11 160623 25
Zone 2 and
in the safe area
Point-to-point, end of line 9186/25-12-11 160625 25
Ring, point-to-point redundant, line 9186/15-12-11 160624 25
Technical Data
Version 9186/12 9186/.5
Installation in Zone 1 Zone 2 and in the safe area
Explosion protection
Europe (ATEX)
Gas and dust BVS 06 ATEX E 145 X BVS 07 ATEX 068 X
E II 2G (1) G Ex e mb ib [ia, op is] IIC T4
E II (1) D [Ex iaD]
E II (1) GD [Ex op is] IIC
E II 3 G Ex nA nC II T4
Certifications and certificates
Certificates ATEX, Kazakhstan (GOST K),
Russia (GOST R), USA (FM)
ATEX, Canada (UL), Kazakhstan (GOST K),
Russia (GOST R), USA (UL)
Ship approval DNV DNV
Safety data
Max. voltage Uo ± 3.7 V – –
Max. current Io 148 mA – –
Max. power Po 137 mW – –
54 Isolators 2013-09-10·KP00·III·en
57. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Fibre Optics Fieldbus Isolating Repeater
Series 9186
Technical Data
Version 9186/12 9186/.5
Installation in Zone 1 Zone 2 and in the safe area
Safety data
For connection RS 485 IS
Max. permissible
voltage Ui
± 4.2 V – –
Internal capacity Ci and
inductivity Li
negligible – –
Ex i fault-contact
Max. permissible
voltage Ui
24 V – –
Max. permissible
current Ii
600 mA – –
Internal capacity Ci and
inductivity Li
negligible – –
Auxiliary power
Nominal voltage UN 24 V DC 24 V DC
Nominal current (at UN) 67 mA 130 mA
Optical interface
Protocols protocol transparent for RS-485 interface protocol transparent for RS-485 interface
Network topologies Ring topology, line topology,
point-to-point connection
Ring topology, line topology,
point-to-point connection
Redundancy automatic switching in case of line fault automatic switching in case of line fault
Connection ST®, BFOC/2.5 connector ST®, BFOC/2.5 connector
Wavelength 850 nm 850 nm
Transmission distance ( 2000 m ( 2000 m
Electrical interfaces
Protocols PROFIBUS DP, Modbus, HART,
ServiceBus R.STAHL (IS1)
PROFIBUS DP, Modbus, HART,
ServiceBus R.STAHL (IS1)
Version RS 485 IS (PNO) RS 485
Connection Sub-D socket X1, 9-pole Sub-D socket X1, 9-pole
Bit rate 1.2 kbit/s ... 1.5 Mbit/s 9.6 kbit/s ... 1.5 Mbit/s
Fault control
Power supply failure Fault-contact is open Fault-contact is open
Transmission level is good LED green and yellow "FO signal",
fault-contact is closed
LED green and yellow "FO signal",
fault-contact is closed
Transmission level
reduced (- 1.5 dBm)
LED yellow "FO signal", fault-contact is open LED yellow "FO signal", fault-contact is open
Fibre breakage or
transmission level is
too low (- 3 dBm)
LED red "FO ERR", fault-contact is open LED red "FO ERR", fault-contact is open
Switching capacity of
fault-contact
see Ex i values max. 60 V DC, 42 V, 1 A
Mechanical data
Weight approx. 200 g approx. 200 g
Mounting type on DIN rail, EN 50022 (NS35/15; NS35/7.5) on DIN rail, EN 50022 (NS35/15; NS35/7.5)
Dimensional Drawings (All Dimensions in mm / inches) - Subject to Alterations
35,2 mm
1.38 "
99 mm / 3.89 "
106 mm / 4.17 "
35,2 mm
1.38 "
114,2 mm / 4.49 "
106,7 mm / 4.20 "
99 mm / 3.89 "
106 mm / 4.17 "
35,2 mm
1.38 "
114,2 mm / 4.49 "
106,7 mm / 4.20 "
06251E00 11335E00 11328E00
126,5 mm / 4.98 "
119 mm / 4.68 "
99 mm / 3.89 "
106 mm / 4.17 "
9186/12-11-11 9186/15-12-11 9186/25-12-11
2013-09-10·KP00·III·en Isolators 55
58. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
HART-Multiplexer
Series 9192
Series 9192 A3
09730E00
WebCode 9192A
> Used for connection of up to
32 HART capable field devices to an
HART management system
> Compatible to Cornerstone, AMS,
FDM, Fieldcare, PDM, PRM etc. and
FDT application
> CommDTM for integration into FDT tools
> Up to 128 HART-Multiplexer on one
PC interface
> Up to 3968 HART field devices
> Galvanic isolation between power supply,
RS 485 bus and HART channels
> For use up to SIL 3 (IEC 61508)
ATEX / IECEx NEC 505 NEC 506 NEC 500
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)
*) Restrictions see table explosion protection
Class I Class I Class II Class III
Selection Table
Version Channels Order number Art. no. PS
HART-Multiplexer
32 9192/32-10-10 160695 21
Series 9192
incl. 14-core connection cable for pac-Carrier Series 9195 or HART connection board Series 9196
CommDTM available, download under the given WebCode 9192A
56 Isolators 2013-09-10·KP00·III·en
59. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
HART-Multiplexer
Series 9192
Technical Data
Explosion protection
Global (IECEx)
Gas IECEx BVS 10.0042X
Ex nAc II T4
Europe (ATEX)
Gas BVS 03 E 213 X
E II 3 G Ex nA II T4
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO), Canada (CSA), Kazakhstan (GOST K), Russia (GOST R),
USA (FM), Belarus (operating authorisation)
Ship approval DNV
Auxiliary power
Nominal voltage UN 24 V DC
Nominal current (24 V) 55 mA
System configuration
09237E00
Field device interface (HART)
Number of channels 16 or 32, setting via switch
Connection Ribbon cable, 14-pole (inclusive)
Signal HART FSK
HART Specification HART Field Communication Protocal Rev. 7.1 (downwards compatible to Rev. 4.0);
FSK Physical Layer Specification (Rev. 7.1)
RS 485 interface
Number 1
Connection Sub-D socket, 9-pole
Signal RS 485
Protocol compatible to Cornerstone, AMS, PDM, PRM, FDM
Number of HART-Multiplexer
per
bus segment
maximum 31
2013-09-10·KP00·III·en Isolators 57
60. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Supply Module
Series 9193
Series 9193 A3
09814E00
WebCode 9193A
> Supply of 24 V DC power supply into
the pac-Bus
> Supply current up to 4 A
(for approx. 30 - 50 modules)
> Single or redundant supply,
decoupled via diodes, with LED indication
> Exchangeable fuses for both supply circuits
> Power supply failure and line fault messaging
via relay contacts
> Different operating modes can be selected
via DIP-switches
(error signal and single / redundant supply)
> Any installation on the pac-Bus
(beginning, end, middle, both sides)
ATEX / IECEx NEC 505 NEC 506 NEC 500
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)
*) Restrictions see table explosion protection
Class I Class I Class II Class III
Selection Table
Version Supply Error messaging Order number Art. no. PS
Supply module
24 V / 4 A,
Line fault and power supply failure 9193/20-11-11s 160717 21
Series 9193
primary + redundant
Note The order numbers listed in the table are for devices equipped with screw-type terminals.
For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with
"k" for spring-type terminals.
58 Isolators 2013-09-10·KP00·III·en
61. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Supply Module
Series 9193
Technical Data
Explosion protection
Global (IECEx)
Gas IECEx BVS 10.0042X
Ex nAc nCc II T4
Europe (ATEX)
Gas BVS 03 E 213 X
E II 3 G Ex nA nC II T4
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO), Canada (CSA), Kazakhstan (GOST K), Korea (KCs),
Russia (GOST R), USA (FM)
Ship approval DNV
Input
Power supply 24 V DC
Input range 18 ... 31.2 V
Redundant supply yes, decoupled with diodes
Safety fuse 5 x 20 mm; 2 x T 4.0 A; exchangeable for prim. and red. supply
Output Supply into the pac-Bus
24 V / maximum 4 A
Error message
Power fail PF Contact (35 V / 100 mA)
Line fault LF Contact (35 V / 100 mA), closed in good conditions
2013-09-10·KP00·III·en Isolators 59
62. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
pac-Bus
Series 9194
Series 9194 A3
02710E00
WebCode 9194A
> Supply for approx. 40 modules per segment
> Usabel for high and low profile DIN rails
(NS35/15 and NS35/7.5)
> Just snap on DIN rail without tools
> Elements can be appended at any time
> Potential free error messaging contact
for common error signal
> Gold plated contacts for
highest contact safety
> Low cost supply via terminals
> Supply module with integrated replaceable
fuses and redundant supply available
ATEX / IECEx NEC 505 NEC 506 NEC 500
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)
*) Restrictions see table explosion protection:
Class I Class I Class II Class III
Selection Table
Version Picture Description Order number Art. no. PS
pac-Bus
Series 9194
09885E00
pac-Bus single element,
raster distance 17.6mm
9194/31-17 160731 21
Terminal set
for pac-Bus
10374E00
5-pole, (set begin + end)
with bridge for error message chain
9194/50-01 160730 21
Technical Data
Explosion protection
Global (IECEx)
Gas IECEx BVS 10.0042X
Ex nAc II T4
Europe (ATEX)
Gas BVS 03 E 213 X
E II 3 G Ex nA II T4
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO), Canada (CSA), Kazakhstan (GOST K), Russia (GOST R),
USA (FM)
Ship approval DNV
Auxiliary power
Max. current 4 A
Connection Screw terminals, 5-pole, maximum 1.5 mm2 or via supply module Series 9193
Mounting type on DIN-rail
Mounting orientation horizontal or vertical
60 Isolators 2013-09-10·KP00·III·en
63. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
pac-Bus
Series 9194
Dimensional Drawing (All Dimensions in mm / inches) - Subject to Alterations
21 mm / 0.82 "
09858E00
3,8 mm / 0.15 "
17,6 mm / 0.69 "
24,2 mm / 0.95 "
22 mm / 0.87 "
37 mm / 1.45 "
15 mm / 0.59 "
2013-09-10·KP00·III·en Isolators 61
64. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
pac-Carrier
Series 9195
Series 9195 A3
14224E00
WebCode 9195A
> pac-Carrier for 8 or 16 modules,
up to 32 signals
> All standard ISpac isolators can be used
> Integration of Ex i and non-Ex i field circuits
in one carrier
> Flexible engineering due to:
– direct allocation between I/O module and
pac-Carrier
– simple connection to
the HART managemet system
– horizontal and vertical installation possible
– installation possible in Zone 2 and Div. 2
> Easy and quick installation due to:
– customized system cables to
automation system
– installation of the isolators without tools
– installation of the carrier on DIN rail or
mounting plate
> Low out of service time of the system due to:
– redundant power supply with
fault detection contact and
exchangeable fuses
– very robust chassis proven by
the DNV approval for ship building
ATEX / IECEx NEC 505 NEC 506 NEC 500
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x x
Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)
*) Restrictions see table explosion protection:
Class I Class I Class II Class III
Selection Table
Version Number of slots Connection HART-Multiplexer Order number PS
pac-Carrier
8 no 9195/08A-...-... 27
Series 9195
9192/32 9195/08H-...-... 27
16 no 9195/16A-...-... 27
9192/32 9195/16H-...-... 27
Customer specific versions for the following DCS: Yokogawa Centum VP, Yokogawa Pro-Safe-RS,
Emerson Delta V, TRICONEX, Invensys, Honeywell, Siemens.
Detailed information about the available pac carrier versions as well as technical documentation you may
download from the internet at www.ispac.info. Engineering and shipment of new versions within 6 weeks.
Technical Data
Explosion protection
Global (IECEx)
Gas IECEx BVS 10.0042X
Ex nAc nCc II T4
Europe (ATEX)
Gas BVS 03 ATEX E 213 X
E II 3 G Ex nA nC II T4
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO), Canada (CSA), Kazakhstan (GOST K), Russia (GOST R),
USA (FM)
62 Isolators 2013-09-10·KP00·III·en
65. A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
pac-Carrier
Series 9195
Technical Data
Auxiliary power
Nominal voltage UN 24 V DC
Redundant supply yes, decoupled with diodes
Fuse 2 x TR5; T 2.0 A; exchangeable, for primary and redundant supply
Connection of field devices
Number of channels 8, 16, 32
System configuration
10154E02
HART interface
PLC or DCS
System cable System cable
pac Carrier 9195
i
p
HART Mux
Ex i
Management System
redundant
Connection - via connection of automation systems
Asset
HART RS485
- via HART multiplexer 9192 (only at 9195/..H-...-...)
Error message
Power fail PF Contact (35 V / 100 mA), closed in good conditions
Dimensional Drawings (All Dimensions in mm / inches) - Subject to Alterations
09826E00
155 mm / 6.10 "
130 mm / 5.12 "
*
144 mm / 5.67 " 130 mm / 5.12 "
Type 9195/08.-...-..., 8 slots
09854E00
155 mm / 6.10 "
130 mm / 5.12 "
*
286 mm / 11.26 " 130 mm / 5.12 "
Type 9195/16.-...-..., 16 slots
* depending on Type, see Engineering Guide
150 mm / 5.91 "
*
150 mm / 5.91 "
*
2013-09-10·KP00·III·en Isolators 63