Appron feeder common ckt-diagram
1. POWER CIRCUIT DIAGRAM OF APPRON FEEDER-019B
L1 150A
Q20 3TF52 SIEMENS
H-7
H-8
H-9
PE
Q2 2A
S 12
P4
R
Y
B
INCOMING FROM CP/NCHP/MCC-4/23 415 V 3PH 4WIRE 50HZ SUPPLY
L2 150A
U
V
W
PE
PE
PE BUS
160 A MCCB
L1
L2
L3
1
2
3
4
5
6
FACTORY FITTED LINK
DC/R+
DC+
U
V
W
A1
Q4 4A
Q5 10A
110V AC CONTROL SUPPLY
T30 415V/110V 1000VA
1L
1N
PE
1
3
2
4
1
2
3
4
Q7 4A
Q8 6A
240V AC SUPPLY
T40 415V/240V 1000VA
2L
2N
PE
1
3
2
4
1
2
3
4
45 KW AC DRIVE SIEMENS MM440
Q1 2A
R
Y
B
Q10
LOCATION : -NCHP PLC ROOM
EQYUPMENT : -APPRON FEEDER 019B
POWER CIRCUIT DIAGRAM
PAGE NUMBER : 1 OF 7
2. 5X1-1
5X1-2
5X1-3
K-1
5X1-4
5X1-5
K-2
APPRON FEEDER-19B CONTROL CIRCUIT DIAGRAM
Q-20
K-2
5X1-6
5X1-7
H-1
K-3
MOTOR START
LINE CONTACTOR ON
DRIVE ON
DRIVE TRIP
REMOTE SETPOINT SELECTOR
H-4
K-4
PULL CHORD SW
LOCAL/REMOTE SEL.SW
STOP PANEL
START PANEL
FIELD EM.STOP
EM.STOP PANEL
1L
1N
LOCATION : -NCHP PLC ROOM
EQYUPMENT : -APPRON FEEDER 019B
CONTROL CIRCUIT DIAGRAM
PAGE NUMBER : 2 OF 7
INCOMING FROM Q5 PAGE-1
3. A/D
A/D
CPU
OPTO-ISOLATION
1
2
3
4
10
11
5
6
7
8
16
17
9
28
14
15
12
13
26
27
20
19
18
22
21
25
24
23
29
30
D/A
D/A
RS 485
0V
AIN1+
AIN1-
AIN2+
AIN2-
DIN1
DIN2
DIN3
DIN4
DIN5
DIN6
ISOLATED OUTPUT-24V
ISOLATED OUTPUT-0V
PTCA
PTCB
AOUT1+
AOUT1-
AOUT2+
AOUT2-
COM
NO
NC
COM
NO
NC
P+
N-
3X1:1
2
3
4
6
5
FROM REMOTE SET POINT
K2
K1
1X1:1
2
3
4
5
6
7
43
44
44
43
T
POT1
P6
SPEED INDICATOR
4X1:1
2
3
4
1L
1N
PCD-01/4.8A
PCD-01/4.8D
K3
K4
PCD – 01 /4.6B
PCD – 01 /4.7B
13
14
21
22
=
3
=
FACTORY FITTED LINK
DC/B+
B+/DC+
B -
DC -
M
L2
U,V,W
U,V,W
PE
L1
Q 20
SIEMENS MM440 DRIVE TERMINAL DETAILS
MCCB-160 AMPS
3TF52
R Y B
LOCATION : -NCHP PLC ROOM
EQYUPMENT : -APPRON FEEDER 019B
CONTROL CIRCUIT DIAGRAM
PAGE NUMBER : 3 OF 7
4. 4
X1 15A
F1 2A
F2 2A
1S1
1S2
1H1
1H2
SECTION-1
PANEL ILLUMINATION
2L:1
2L:2
2L:3
F3 6A
2N2
SERVICE PURPOSE SOCKET
PE
X2 15A
S11
2L:4
Q3 4A
2N3
X3 15A
1
2
COOLING FAN
EF1
2N1
2L:5
1
2
2N4
Q6 2A
SPEED INDICATOR
2L
2N
LOCATION : -NCHP PLC ROOM
EQYUPMENT : -APPRON FEEDER 019B
CONTROL CIRCUIT DIAGRAM
PAGE NUMBER : 4 OF 7
5. 5
110 V FROM PLC PANEL-2 6AMPS MCB
5X1-13
K1
5X1-11
3PL3:02
I 136.2
Q20
I 136.1
5X1-12
3PL3:01
REMOTE SEL
EMG STOP
K3
Q110.3
5X1-10
3PL1:03
ON COMMAND
K4
I 136.0
5X1-9
3PL3:00
DRIVE FAULT
PLC TERMINALS
DRIVE PANEL TERMINALS
LOCATION : -NCHP PLC ROOM
EQYUPMENT : -APPRON FEEDER 019B
CONTROL CIRCUIT DIAGRAM
PAGE NUMBER : 5 OF 7
6. 6
DRIVE FAULT
2PL9-2
2L-118
3PL3:00
I 136.0
5X1-2
EMG.STOP.PB
2PL9-3
3PL3:01
I 136.1
5X1-3
REMOTE.SEL
2PL9-4
3PL3:02
I 136.2
5X1-4
ON.F/B
2PL9-6
3PL3:03
I 136.3
5X1-5
ON.CMD
3PL1:03
Q 110.3
TERMINAL AT PLC PANEL-2
MARSHALLING
TERMINAL AT PLC PANEL-3
I/O DETAILS
DRIVE PANEL
REFERENCE PLC DATA
LOCATION : -NCHP PLC ROOM
EQYUPMENT : -APPRON FEEDER 019B
CONTROL CIRCUIT DIAGRAM
PAGE NUMBER : 6 OF 7
BLOCK DIAGRAM OF CONTRO CABLE LAY OUT
DRIVE PANEL
PLC PANEL-2
PLC PANEL-3
LCS JB
7. 08-11-2014
7
APPRON FEEDER 019B LCS DETAILS
BLUE CABLE
BLUE CABLE
YELLOW CABLE
1
2
3
YELLOW CABLE
GREY CABLE
4
5
GREY CABLE
7
6
GREY CABLE
NOTE : -
1) PULL CHORD IS IN SERIES WITH FIELD EMERGENCY STOP PB.
2) 16 CORE 2.5 MM2 CABLE IN BETWEEN LCS AND APPRON FEEDER 019 B DRIVE PANEL
LOCATION : -NCHP PLC ROOM
EQYUPMENT : -APPRON FEEDER 019B
CONTROL CIRCUIT DIAGRAM
PAGE NUMBER : 7 OF7