Student can show there Id cards to accessing system to move inside the campus also to go outside campus . This clearly shows in/out timing of particular student.
3. Components of System
• RFID HF tags or Biometric.
• Flap barrier turnstile.
• RFID Fixed reader.
• Window application.
4. RFID High Frequency Tags
• The details of authorized student is mapped to Tags.
• They operate at 13.56 MHz with read ranges approximate 7cm.
• It experience moderate sensitivity to interference.
5. Fingerprint Biometric
• These are used to determine the uniqueness of the fingerprint.
• Once registered on the fingerprint scanner, the image of these
patterns is converted into a digital form.
• This is stored on a database for comparison which grants
authentication and access through the Flap barrier.
6. Flap barrier
• It is pedestrian barrier installed in conjunction with any access control
system provides valuable assistance to security personnel at any
monitored entrance.
• Its combine features like high throughput rate, user acceptance,
comfort and different levels of security to prevent unauthorized
access pedestrian safety has also been taken into account.
• They are compatible with most access control systems, such as
magnetic, biometric and proximity readers.
7. RFID Fixed reader
• It detects the authorized students.
• Allows Flap barrier to open/close.
8. Window Application
• It is an external control on flap barrier using desktop through Window
application.
• Uploads the data to server through LAN , Wi-Fi within campus range.
10. Working
• Normally Closed Working Mode (Default): after authorization by a
RFID reader or Biometric .
• Operate symbols on top of the unit changes from a red cross into a
green arrow.
• After passing finish, it will close immediately.
• To allow larger capacity through the Flap Barrier, the authorized
number can be memorized.
11. Normally Open Working Mode
• The arms will always open and only closes if an unauthorized visitor
steps into the Flap Barrier.
• After authorization the display on the top plate shows a green arrow
and the user can walk through the lane.
12. The visitors detection and alarming in
normally closed / Open mode
• Stand by.
• Following After Authorized Passage.
• Counter Direction Intrusion Alarming.
13. • Overtime Alarming.
• Stay Intrusion Alarming.
• Emergency Open / Close Mode.
• Degradation Mode.
14. Emergency Open / Close
Mode
• Emergency modes is used in special applications, such as fire alarm,
etc.
• In those modes, the authorization will be shield and arms remains
open/close till input any signal to change be other mode.
15. Degradation Mode
• This mode appears when the detection cell are broken or blocked
during initialization.
• authorization is valid but all of the detection cell are shield, the arms
will only close the after the valid time.