2. " " brand air conditioners promise to make your daily life more comfortable, and are highly valued by customers in more than
100 countries around the world.
Since starting our air conditioner business in the Middle East, our air conditioners have earned
a high reputation for being able to withstand severe high temperatures like those encountered in tropical and desert regions.
We are also developing innovating new technologies, such as the DC inverter, automatic clean filter, and VRF system,
in our pursuit of a more comfortable room. You can feel the difference. Welcome to " "!
Duct Type
[p.24-p.27]
Cassette Type
[p.22-p.23]
Multi-Type Systems
[p.28-p.29]
R410A
R410A
R410A
R410A
R410A
R410A
R410A
R410A
R410A
R410A
R410A
R407A
R407A
R407A
R407A
R410A
R410A
R410A
R410A
R410A
ARG7/9F ARG7/9U
ARG12/14F/18A
ARG12/14U/18R
ARG18A(HT)
ARG90E/90T
ARG60A/60R
ARG25/36/45A
ARG25/30/36/45R
ARG25/30A(HT)
ARG18A(HT)
ARG25A(HT)
ARG30A(HT)
ARG7F
ARG7U
ARG9F
ARG9U
ARG12F
ARG12U
ARG14F
ARG14U
ARG18A
ARG18R
ARG25A
ARG25R
ARG30R
ARG36A
ARG36R
ARG45A
ARG45R
ARG60A
ARG60R
ARG90E
ARG90T
Inverter Hyper Tropical
Floor/Ceiling Universal Type Ceiling (large) Type
[p.20-p.21]
Hyper Tropical Hyper Tropical
" " brand air conditioners are selected & loved around the world
2 & 3-4 Room Multi (Inverter)
2 Room Multi
AOH19F
AOH19U
AOH24F
AOH24U
AJGA90E
AJGA90T
AUG12A
AUG12R
AUG18A(HT)
AUG18R
AUG36/45/54A
AUG25/30/36/45/54R
AUG25/30A(HT)
AUG12A
AUG12R
AUG18R
AUG25R
AUG30R
AUG36A
AUG36R
AUG45A
AUG45R
AUG54A
AUG54R
AUG18A(HT)
AUG25A(HT)
AUG30A(HT)
ABG18/24R
ABG18/24R(HT)
ABG18/24A
ABG18/24A(HT)
ABG30/36/45/54RABG36/45/54A
ABG30A(HT)
ABG18A
ABG18R
ABG24A
ABG24R
ABG30R
ABG36A
ABG36R
ABG45A
ABG45R
ABG54A
ABG54R
ABG18A(HT)
ABG18R(HT)
ABG24A(HT)
ABG24R(HT)
ABG30A(HT)
AOGG18LAC2
AOGG18LAT3
AOGG24LAT3
AOGG30LAT4
2
4. 4
WALL MOUNTED TYPE
1.Improvement of compressor drive materials
for greater durability (Hardness increased).
2.Use of high efficiency, high torque motor
3.Complete protection functions against
abnormal temperature rise and abnormal
pressure rise
Main features
HYPER TROPICAL
COMPRESSOR
Temperature rise prevention
device (thermal protector) installed
High-output torque motor Torque improved by
increasing the thickness of the laminated
core and improving the coil winding
High durability crankshaft used Hardness
improved by adding a coating
Gas leak protection and low voltage protection
OLP (Over Load Protection) device installed
High durability rolling piston Hardness
improved by changing the material
High durability vane
Surface hardness increased
SUPER PROTECTION
(for Cooling type)
Enhancement of protection function
Strong blue fin
Adoption of strong
blue fin provides
strong protection
against rust and salt
damage.
HYPER TROPICAL SPEC
Super power
10% more capacity than old models
under overload condition (52°C).
Super low voltage operation
Our Hyper Tropical Compressor
can be operated even at low voltage.
Super Hi-EER
5-10% higher than our old model.
Super quiet
Reduces the noise level
about 3dB at 220V operation.
30% improved powerful airflow5 speed control
New super cooling
750-840
880-950
Air flow is 30% or 28% stronger than current model.5-speed control provides a variety of airflow and quiet operation.
1,090-1,090
1,220-1,220
Powerful
High
Med
Low
Quiet
High
Med
Low
18 type
24 type
New Model
(220V-240V)
Current Model
(220-240V)
30%higher
28%higher
15M Long-reach
airflow
Direct airflow
from top
Airflow
30%higher
High efficiency
DC Fan motor
Large power diffuser
Quick
cooling
Quiet
New Model Current Model
5. 5
SPECIFICATIONS
Model No. Indoor Unit
Outdoor Unit
Capacity Class
Input Power
Capacity Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
BTU/h
BTU/h
V/ø/Hz
kW
kW
kW/kW
A
Power Consumption
EER
Running Current
Moisture Removal
Room Air Circulation (High)
Pints/h
Liter/h
C.F.M
(m3
/h)
H / W / D (mm)
kg(lbs)
H / W / D (mm)
kg(lbs)
Indoor Unit Dimensions
Weight
Outdoor Unit Dimensions
Weight
Refrigerant
Connection Method
ASGA24AFT
AOGR24AFT
ASGA18AFT
AOGR18AFT
Cooling/Heating capacities are based on the following conditions.
Cooling
Indoor temperature : 27O
C DB/19O
C WB
Outdoor temperature : 35O
C DB/(24O
C WB)
All air conditioners are single-phase types.
Specifications and design subject to change without notice for further improvement.
Please check with your dealer.
Heating
Indoor temperature : 20O
C DB
Outdoor temperature : 7O
C DB/6O
C WB
ASGA18AFT
5.30-5.30kW / 18,100-18,100BTU/h
ASGA24AFT
7.03-7.03kW / 24,000-24,000BTU/h
Dimensions = H320 x W998 x D238mm
Handy Type
For
ASGA18/24AFT
ASGA24/18AFT
Quiet operation mode
New Quiet mode realizes quiet environment in night time. It is useful for the bed room, etc.
And also sound of outdoor unit is reduced by adopting rotary compressor and quiet fan.
Double auto swing
34 db(A)
35 db(A)
53 db(A)
54 db(A)
Indoor unit
Quiet cooling mode (220V-240V)
Outdoor unit
(220V-240V)
18,000
240-220 / 1/ 50
18,100-18,100
-
5.30-5.30
-
2.00-1.90
-
2.65-2.79
-
8.8-8.8
-
4.3
(2.0)
579
(985)
320x998x238
14.0 (31)
650x830x320
46.0 (101)
R22
Flare
24,000
240-220 / 1/ 50
24,000-24,000
-
7.03-7.03
-
2.68-2.53
-
2.62-2.78
-
12.8-11.9
-
5.3
(2.5)
641
(1090)
320x998x238
14.0 (31)
650x830x320
57.0 (125)
R22
Flare
Optional
18 type
24 type
-step5-step6
High energy efficiency
EER is improved by energy
saving design.
2.78
2.69
Current Model New Model (*24 type, 220V)
6. 6
HANDY TYPE REMOTE CONTROLLER
3
4
5
6
2
1
9
10
11
12
8
7
Auto Swing Louver
6-step air directions by auto swing louver.
Steps Swing
Squeaking sound is eliminated by
simplifying the construction of resin parts
and using soft resin at parts where stress
is concentrated.
Consideration given
to noise reduction
One-piece panel
(Unification of parts)
Adopting soft type resin
Base and casing integrated molding
Temp./Time Set Button
Master Control Button/
Code Change Button
Vertical Swing Button
Vertical Set Button
9
10
11
12
Timer Button
Remote Control Unit Display(LCD)
Fan Control Button
Horizontal Swing Button
3
4
2
1
8
7
5
6
Horizontal Set Button
Start/Stop Button
Signal Transmitter
Sleep Button
Multi airflow
Heating:Wide down flow.
SwingSteps
Cooling Heating
Large independently driven power diffusers used
Cooling:
Horizontal concentration
and other air direction
control.
SPECIFICATIONS
Model No. Indoor Unit
Outdoor Unit
Capacity Class
Input Power
Capacity Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
BTU/h
BTU/h
V/ø/Hz
kW
kW
kW/kW
A
Power Consumption
EER
Running Current
Moisture Removal
Room Air Circulation (High)
Pints/h
Liter/h
C.F.M
(m3
/h)
H / W / D (mm)
kg(lbs)
H / W / D (mm)
kg(lbs)
Indoor Unit Dimensions
Weight
Outdoor Unit Dimensions
Weight
Refrigerant
Connection Method
Cooling/Heating capacities are based on the following conditions.
Cooling
Indoor temperature : 27O
C DB/19O
C WB
Outdoor temperature : 35O
C DB/(24O
C WB)
All air conditioners are single-phase types.
Specifications and design subject to change without notice for further improvement.
Please check with your dealer.
Heating
Indoor temperature : 20O
C DB
Outdoor temperature : 7O
C DB/6O
C WB
ASG30R
AOGR30R
30,000
240-220 / 1/ 50
27,300-26,600
30,000-29,200
8.00-7.80
8.80-8.55
3.05-2.93
3.25-3.13
2.62-2.66
2.71-2.73
13.5-13.7
14.4-14.5
6.4
(3.0)
618-600
(1,050-1,020)
320 x 1,120 x 220
16.0 (35)
830 x 900 x 330
74.0 (163)
R22
Flare
ASG24R
AOG24R
24,000
240-220 / 1/ 50
23,500-23,200
26,600-26,300
6.90-6.80
7.80-7.70
2.74-2.65
2.60-2.51
2.52-2.57
3.00-3.07
12.8-12.6
12.3-12.0
5.3
(2.5)
559-518
(950-880)
320 x 1,120 x 220
16.0 (35)
643 x 840 x 336
68.0 (150)
R22
Flare
ASG18R
AOG18R
18,000
240-220 / 1/ 50
18,400-18,100
19,100-18,800
5.40-5.30
5.60-5.50
2.23-2.20
1.94-1.89
2.42-2.41
2.89-2.91
10.2-10.6
9.3-9.2
4.3
(2.0)
494-441
(840-750)
320 x 1,120 x 220
16.0 (35)
643 x 840 x 336
68.0 (150)
R22
Flare
ASG30A
AOGR30A
30,000
240-220 / 1/ 50
28,000-27,500
-
8.20-8.05
-
3.08-2.96
-
2.66-2.72
-
13.7-13.8
-
6.4
(3.0)
618-600
(1,050-1,020)
320 x 1,120 x 220
16.0 (35)
830 x 900 x 330
72.0 (159)
R22
Flare
ASG24A
AOGR24A
24,000
240-220 / 1/ 50
23,600-23,200
-
6.90-6.80
-
2.72-2.62
-
2.54-2.60
-
13.4-12.8
-
5.3
(2.5)
559-518
(950-880)
320 x 1,120 x 220
16.0 (35)
643 x 840 x 336
63.0 (138)
R22
Flare
ASG18A
AOG18A
18,000
240-220 / 1/ 50
18,400-18,100
-
5.40-5.30
-
2.18-2.12
-
2.48-2.50
-
10.1-9.9
-
4.3
(2.0)
494-441
(840-750)
320 x 1,120 x 220
16.0 (35)
643 x 840 x 336
57.0 (125)
R22
Flare
WALL MOUNTED TYPE
7. 7
Handy Type
ASG24A(HT)
6.90-6.80kW / 23,600-23,200BTU/h
ASG30A(HT)
8.20-8.05kW / 28,000-27,500BTU/h
ASG24R/24A/
18R/18A(HT)
For
ASG18A/18R/
24A/24R(HT)
For
ASG30A/30R(HT)
Compact outdoor unit
ASG30R/30A(HT)
ASG24R(HT)
6.80-6.60kW / 23,200-22,500BTU/h
7.80-7.60kW / 26,600-25,900BTU/h
ASG30R(HT)
8.00-7.80kW / 27,300-26,600BTU/h
8.80-8.55kW / 30,000-29,200BTU/h
Handy Type
For
ASG18A/18R/24A/24R
ASG24R/24A/18R/18A
For
ASG30A/30R
Compact outdoor unit
ASG30R/30A
Dimensions = H320 x W1,120 x D220mm
Dimensions = H320 x W1,120 x D220mm
ASG24A
6.90-6.80kW / 23,600-23,200BTU/h
ASG24R
6.90-6.80kW / 23,600-23,200BTU/h
7.80-7.70kW / 26,600-26,300BTU/h
ASG30A
8.20-8.05kW / 28,000-27,500BTU/h
ASG30R
ASG18A
5.40-5.30kW / 18,400-18,100BTU/h
ASG18R
5.40-5.30kW / 18,400-18,100BTU/h
5.60-5.50kW / 19,100-18,800BTU/h
8.00-7.80kW / 27,300-26,600BTU/h
8.80-8.55kW / 30,000-29,200BTU/h
ASG18A(HT)
5.50-5.40kW / 18,800-18,400BTU/h
ASG18R(HT)
5.40-5.30kW / 18,400-18,100BTU/h
5.60-5.50kW / 19,100-18,800BTU/h
ASG30R(HT)
AOG30R(HT)
30,000
240-220 / 1/ 50
27,300-26,600
30,000-29,200
8.00-7.80
8.80-8.55
3.05-2.93
3.25-3.13
2.62-2.66
2.71-2.73
13.5-13.7
14.4-14.5
6.4
(3.0)
618-600
(1,050-1,020)
320 x 1,120 x 220
16.0 (35)
900 x 900 x 350
80.0 (176)
R22
Flare
ASG24R(HT)
AOG24R(HT)
24,000
240-220 / 1/ 50
23,200-22,500
26,600-25,900
6.80-6.60
7.80-7.60
2.66-2.53
2.68-2.53
2.56-2.61
2.91-3.00
12.2-12.0
12.4-12.0
5.3
(2.5)
559-518
(950-880)
320 x 1,120 x 220
16.0 (35)
650 x 830 x 320
60.0 (132)
R22
Flare
ASG18R(HT)
AOG18R(HT)
18,000
240-220 / 1/ 50
18,400-18,100
19,100-18,800
5.40-5.30
5.60-5.50
1.91-1.83
1.75-1.70
2.83-2.90
3.20-3.24
8.5-8.5
7.8-7.8
4.3
(2.0)
491-441
(840-750)
320 x 1,120 x 220
16.0 (35)
650 x 830 x 320
56.0 (123)
R22
Flare
ASG30A(HT)
AOG30A(HT)
30,000
240-220 / 1/ 50
28,000-27,500
-
8.20-8.05
-
3.00-2.85
-
2.73-2.83
-
13.6-13.3
-
6.4
(3.0)
618-600
(1,050-1,020)
320 x 1,120 x 220
16.0 (35)
900 x 900 x 350
79.0 (174)
R22
Flare
ASG24A(HT)
AOGR24A(HT)
24,000
240-220 / 1/ 50
23,600-23,200
-
6.90-6.80
-
2.67-2.53
-
2.58-2.69
-
12.8-12.2
-
5.3
(2.5)
724-688
(1230-1170)
320 x 1,120 x 220
16.0 (35)
650 x 830 x 320
57.0 (125)
R22
Flare
ASG18A(HT)
AOGR18A(HT)
18,000
240-220 / 1/ 50
18,800-18,400
-
5.50-5.40
-
1.89-1.84
-
2.91-2.93
-
8.4-8.4
-
4.3
(2.0)
494-441
(840-750)
320 x 1,120 x 220
16.0 (35)
650 x 830 x 320
46.0 (101)
R22
Flare
8. 8
SPECIFICATIONS
Model No. Indoor Unit
Outdoor Unit
Capacity Class
Input Power
Capacity Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
BTU/h
BTU/h
V/ø/Hz
kW
kW
kW/kW
A
Power Consumption
EER
Running Current
Moisture Removal
Room Air Circulation (High)
Pints/h
Liter/h
C.F.M
(m3
/h)
H / W / D (mm)
kg(lbs)
H / W / D (mm)
kg(lbs)
Indoor Unit Dimensions
Weight
Outdoor Unit Dimensions
Weight
Refrigerant
Connection Method
Air conditioner filter features
0
0
40
80
120
160
30 60 120
(ppm)
(min)
Ammonia
With no filter
New filter
0
0
40
80
120
160
30 60 120
(ppm)
(min)
Trimethylamine
With no filter
0
0
40
80
120
160
30 60 120
(ppm)
(min)
Hydrogen sulfate
With no filter
Ion deodorization filter Apple-catechin filter
Dirty Air
Clean Air
Long-life* Ion
deodorization filter
The filter deodorizes by powerfully
decomposing absorbed odors using the
oxidizing and reducing effects of ions
generated by the ultra-fine-particle ceramic.
(* The filter can be used for approx. 3 years
if it is washed under water to restore its
surface action when it is dirty.)
Fine dust, invisible mold spores, and
harmful microorganisms are absorbed
onto the filter by static electricity, and
further growth is inhibited and
deactivated by the polyphenol ingredient
extracted from apples.
Testing organization : Environmental Sanitary
Inspection Center
Test method : Deodorization Test
Deodorizing effect
(Odor reduction rate)
ASG12A
AOG12A
12,000
240-220 / 1/ 50
11,800-11,600
-
3.45-3.40
-
1.33-1.27
-
2.59-2.68
-
6.2-6.1
-
4.0
(1.8)
318
(540)
257 x 808 x 187
8.0 (18)
535 x 695 x 250
30.0 (66)
R22
Flare
ASG9A
AOG9A
9,000
240-220 / 1/ 50
8,900-8,900
-
2.60-2.60
-
0.89-0.86
-
2.92-3.02
-
3.9-4.0
-
2.9
(1.3)
318
(540)
257 x 808 x 187
8.0 (18)
535 x 650 x 250
24.0 (53)
R22
Flare
12,000
230 / 1 / 50
11,100
13,000
3.25
3.80
1.31
1.22
2.48
3.11
6.20
5.70
4.0
(1.8)
318
(540)
257 x 808 x 187
8.0 (18)
535 x 695 x 250
31.0 (68)
R22
ASH12R
AOH12R
Flare
ASG7R
AOG7R
7,000
240-220 / 1/ 50
7,000-7,000
7,900-7,900
2.05-2.05
2.30-2.30
0.73-0.70
0.69-0.65
2.81-2.93
3.33-3.54
3.3-3.3
3.1-3.1
1.8
(0.8)
206
(350)
248 x 808 x170
7.5 (17)
535 x 650 x 250
25.0 (55)
R22
Flare
9,000
230 / 1 / 50
8,500
10,100
2.50
2.95
1.00
0.86
2.50
3.43
4.80
4.30
2.9
(1.3)
318
(540)
257 x 808 x 187
8.0 (18)
535 x 650 x 250
25.0 (55)
R22
ASH9R
AOH9R
Flare
ASG7A
AOG7A
7,000
240-220 / 1/ 50
6,700-6,700
-
1.95-1.95
-
0.64-0.59
-
3.07-3.31
-
2.9-2.8
-
1.5
(0.7)
200
(340)
248 x 808 x 170
7.5 (17)
535 x 650 x 250
24.0 (53)
R22
Flare
Cooling/Heating capacities are based on the following conditions.
Cooling
Indoor temperature : 27O
C DB/19O
C WB
Outdoor temperature : 35O
C DB/(24O
C WB)
All air conditioners are single-phase types.
Specifications and design subject to change without notice for further improvement.
Please check with your dealer.
Heating
Indoor temperature : 20O
C DB
Outdoor temperature : 7O
C DB/6O
C WB
WALL MOUNTED TYPE
9. 9
Dimensions = H248 x W808 x D170mm
Handy Type
Handy Type
Handy Type
Plastic cabinet
outdoor unit
Dimensions = H257 x W808 x D187mm
ASH12R
3.25kW / 11,100BTU/h
3.80kW / 13,000BTU/h
Plastic cabinet
outdoor unit
For ASH9R
ASH9R
Plastic cabinet
outdoor unit
For ASH12R
ASH12R
Dimensions = H257 x W808 x D187mm
Plastic cabinet
outdoor unit
For ASG9A
ASG9A
For ASG12A
Plastic cabinet
outdoor unit
ASG12A
ASG7A
1.95-1.95W / 6,700-6,700BTU/h
ASG7R
2.05-2.05kW / 7,000-7,000BTU/h
2.30-2.30kW / 7,900-7,900BTU/h
ASH9R
2.50kW / 8,500BTU/h
2.95kW / 10,100BTU/h
ASG12A
3.45-3.40kW / 11,800-11,600BTU/h
ASG9A
2.60-2.60kW / 8,900-8,900BTU/h
Easy-to-install & easy-to-operate wall
mounted type for a comfortable life
Optional
10. 10
Test method: JEM1467 Test room : 1m , acrylic sealed box
Measurement method: Cigarette smoke (5 cigarettes burned simultaneously)
0 5 10 15 20 25 30
Collects dirt such as...
House dust / Pet fur and dander /
Cigarette smoke / Mite carcass / Mold spore / Pollen
Absorbs odors such as...
Smell of cigarette smoke / Pet odor /
Kitchen garbage smell / Perspiration and body odor
Plasma air cleaner quickly removes
small dust particles & odors
Dust collection performance
(ASHB09/12/18L)
0 5 10 15 20 25 30
Time (mins) Time (mins) Time (mins)
Residualratio%
Residualratio%
Residualratio%
Deodorizing performance
(ASHB09/12/18L)
Acetic acid
0 30
Ammonia
Bacteria elimination effect by Polyphenol ceraglaze
Tested by KITAZATO environment science center
Test NO. :15-0253 Test condition: at 20 degrees C/24 hour action
The undiluted solution of the specimen was made the specimen fluid and
suspensoid 0.1ml (approx. 107CFU/ml) of the test bacteria was inoculated.
Inner drying operation & plasma effect
Bacteria grows in beading,
and it causes bad odor. Ozone bacteria eliminating
operation for approx. 15 mins
Removes moisture
Bacteria elimination
Covered with beading
03
03
03
03
Drying operation
for approx. 15 mins
Dust collection
efficiency 54.3%
Removal ratio
90%
90
80
70
60
40
100
50
90
80
70
60
40
100
20
90
80
70
60
40
100
50
Test method: JEM 1417 Test room: 30m , sealed room
Measurement conditions: Cigarette smoke (5 cigarettes burned
simultaneously)
3 3
After operation ends, start
approx. 30 minutes speed
cleaning operation by merely
pressing the COIL DRY button.
Removal ratio
58%
This model is equipped with an inner drying function. After the power is turned off,
the dry operation starts inside the air conditioner. The plasma air cleaning unit eliminates bacteria,
deodorizes, and keeps the interior of the air conditioner clean by generating ozone and ions.
SPECIFICATIONS
Model No. Indoor Unit
Outdoor Unit
Capacity Class
Input Power
Capacity Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
BTU/h
BTU/h
V/ø/Hz
kW
kW
kW/kW
A
Power Consumption
EER
Running Current
Moisture Removal
Room Air Circulation (High)
Pints/h
Liter/h
C.F.M
(m3
/h)
H / W / D (mm)
kg(lbs)
H / W / D (mm)
kg(lbs)
Indoor Unit Dimensions
Weight
Outdoor Unit Dimensions
Weight
Refrigerant
Connection Method
Cooling/Heating capacities are based on the following conditions.
Cooling
Indoor temperature : 27O
C DB/19O
C WB
Outdoor temperature : 35O
C DB/(24O
C WB)
All air conditioners are single-phase types.
Specifications and design subject to change without notice for further improvement.
Please check with your dealer.
Heating
Indoor temperature : 20O
C DB
Outdoor temperature : 7O
C DB/6O
C WB
ASHB24LD
AOHS24LD
24,000
230/1/50
24,200(3,100-27,300)
27,600(3,100-36,200)
7.10(0.9-8.0)
8.10(0.9-10.6)
2.21(0.11-2.62)
2.24(0.11-3.68)
3.21
3.62
9.70
9.80
6.4
(3.0)
688
(1,170)
320x998x228
14.0 (31)
578x790x315
44(97)
R410A
Flare
ASHB18LD
AOHS18LD
18,000
230/1/50
17,700(3,100-19,400)
21,300 (3,100-31,000)
5.20 (0.9-5.7)
6.25 (0.9-9.1)
1.72 (0.09-2.00)
1.73 (0.09-2.66)
3.02
3.61
7.60
7.70
6.0
(2.8)
412
(700)
283x790x230
10(22)
578x790x300
40(88)
R410A
Flare
ASHB12LD
AOHS12LD
12,000
230/1/50
11,900 (3,100-14,700)
16,400 (3,100-22,900)
3.50(0.9-4.3)
4.80(0.9-6.7)
0.91(0.25-1.61)
1.22(0.25-2.30)
3.85
3.93
4.30
5.50
4.0
1.8
350
(595)
283x790x230
9.5(21)
540x790x290
36(80)
R410A
Flare
ASHB09LD
AOHS09LD
9,000
230/1/50
8,900 (1,700-12,600)
12,300 (1,700-20,800)
2.60(0.5-3.7)
3.60(0.5-6.1)
0.61(0.25-1.38)
0.81(0.25-1.96)
4.26
4.44
2.90
3.90
2.9
1.3
329
(560)
283x790x230
9.5(21)
540x790x290
34(75)
R410A
Flare
WALL MOUNTED TYPE
INVERTER
“Inner drying operation” and “ozone bacteria eliminating operation”
keep the inside of the air conditioner clean at all times. That’s why air
from the air conditioner is always clean and high efficiency is realized.
11. 11
Dimensions = H283 x W790 x D230mm
Dimensions = H320 x W998 x D228mm
Dirty Air
High efficiency layout
Plasma air filter mechanism
Mounts a plasma air cleaning unit. Minute
dust particles are collected by an
electrostatic filter and odor is suppressed
by decomposition of foul odors by very
weak ions. Since a filter with a lower
ventilation resistance than in the past is
used, high dust collection design
simultaneously cleans the air in the room.
Original plasma air cleaning
unit effectively cleans
the air in the room
Pet odor and the smell of
cigarette smoke are removed
by decomposition by weak
ozone O3
Clean AirEarth conductor
Plasma filter generates ions and ozone
Electric pole
Dirty Air
Restored to the same performance as
when new each time it is washed
Wireless R.C.
(09/12/18)
Wireless R.C.
(24)
ASHB09/12/18LD
(09) (12/18/24)
ASHB12/09LD
For
ASHB09/12LD
ASHB24/18LD
For
ASHB18/24LD
Wired R.C.
(24)
Optional
ASHB24LD
7.10kW / 24.200BTU/h
8.10kW / 27.600BTU/h
ASHB09LD
2.60kW / 8.900BTU/h
3.60kW / 12.300BTU/h
ASHB12LD
3.50kW / 11.900BTU/h
4.80kW / 16.400BTU/h
ASHB18LD
5.20kW / 17.700BTU/h
6.25kW / 21.300BTU/h
Clean Air
Washable filter
Electrostatic filter Polyphenol filter
(Grapefruit seed extract)
Activated charcoal bacteria eliminating
and deodorizing filter
Negatively-charged dust, etc. are
attracted to the earth section and are
collected by a bacteria eliminating and
deodorizing filter
12. 12
Cooling/Heating capacities are based on the following conditions.
Cooling
Indoor temperature : 27O
C DB/19O
C WB
Outdoor temperature : 35O
C DB/(24O
C WB)
All air conditioners are single-phase types.
Specifications and design subject to change without notice for further improvement.
Please check with your dealer.
Heating
Indoor temperature : 20O
C DB
Outdoor temperature : 7O
C DB/6O
C WB
SPECIFICATIONS
Model No. Indoor Unit
Outdoor Unit
Capacity Class
Input Power
Capacity Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
BTU/h
BTU/h
V/ø/Hz
kW
kW
kW/kW
A
Power Consumption
EER
Running Current
Moisture Removal
Room Air Circulation (High)
Pints/h
Liter/h
C.F.M
(m3
/h)
H / W / D (mm)
kg(lbs)
H / W / D (mm)
kg(lbs)
Indoor Unit Dimensions
Weight
Outdoor Unit Dimensions
Weight
Refrigerant
Connection Method
Compact-Sized
Indoor Unit
Top-class compact size by
realizing high efficiency
in the industry
Realizing high-density
heat transfer tube
arrangement
by making the tube thin
Realizing high-density
heat transfer tube
arrangement by making
the tube thin
Improved the heat
exchanger effectiveness
Making the tube
Thin:7mm 5mm
Conventional type
Volume
-10%
215
275
198
260
Simple and compact design fits any interior decor
Volume reduction of heat
exchange: 30%
Even temperature
Open panel
Easy maintenance
Since the front panel is easy to
remove, maintenance is also easy
Easy maintenance and always clean.
Troublesome maintenance has
been made easy
Quiet operation
Cooling mode
(ASHA07/09/12 TYPE)
(ASHA07/09/12 )
Fan speed Noise level
Quiet 21dB(A)
Washable panel
ASHA24LF
AOHR24LF
24,000
230/1/50
24,200(3,100-27,000)
27600 (3,100-36,200)
7.10 (0.90-8.00)
8.10 (0.90-10.60)
2.21
2.24
3.21
3.62
9.70
9.80
6.3
(3.0)
650
(1,100)
320x998x228
14.0 (31)
578x790x315
44.0 (97)
R410A
Flare
ASHA18LE
AOHR18LE
18,000
230/1/50
17,700(3,100-20,500)
21,500(3,100-31,000)
5.20 (0.90~6.00)
6.30 (0.90~9.10)
1.57
1.71
3.31
3.68
6.80
7.60
6.2
(2.8)
530
(900)
320x998x228
14.0 (31)
620x790x298
41.0 (90)
R410A
Flare
ASHA14LG
AOHR14LG
14,000
230/1/50
13600(3,100-17,100)
17,100(3,100-23,900)
4.00 (0.90~5.00)
5.00 (0.90~7.00)
1.08
1.30
3.70
3.86
4.90
5.70
4.6
(2.1)
470
(800)
260x790x198
7.5 (17)
620x790x298
41.0 (90)
R410A
Flare
ASHA12LG
AOHR12LG
12,000
230/1/50
11,600(3,100-13,300)
13,600(3,100-19,100)
3.40 (0.90-3.90)
4.00 (0.90-5.60)
0.90
0.97
3.80
4.12
4.30
4.60
3.8
(1.8)
441
(750)
260x790x198
7.5 (17)
540x660x290
32.0 (71)
R410A
Flare
ASHA09LG
AOHR09LG
9,000
230/1/50
8,500(1,700-10,900)
10,900(1,700-15,300)
2.50 (0.50-3.20)
3.20 (0.50-4.50)
0.63
0.75
3.97
4.27
3.20
3.70
2.7
(1.3)
441
(750)
260x790x198
7.5 (17)
540x660x290
25.0 (55)
R410A
Flare
ASHA07LG
AOHR07LG
7,000
230/1/50
7,200(1,700-10,200)
10,200(1,700-15,300)
2.10 (0.50~3.00)
3.00 (0.50~4.50)
0.47
0.66
4.47
4.55
2.40
3.20
2.2
(1.0)
441
(750)
260x790x198
7.5 (17)
540x660x290
25.0 (55)
R410A
Flare
ASHA30LF
AOHR30LF
30,000
230/1/50
27,300 (9,900-30,700)
30,700 (7,500-37,600)
8.00(2.90-9.00)
9.00(2.20-11.0)
2.66
2.64
3.01
3.41
11.70
11.60
7.2
(3.4)
650
(1,100)
320x998x228
14.0 (31)
830x900x330
62.0 (137)
R410A
Flare
WALL MOUNTED TYPE
INVERTER
13. 13
Dimensions = H320 x W998 x D228mm
Dimensions = H260 x W790 x D198mm
Simple & Elegant Appearance Design
Ensuring Compatibility with Compact Energy Saving
ASHA12/09/07LG
For
ASHA07/09/12LG
ASHA14LG
For
ASHA14LG
(07/09) (12)
ASHA07LG
2.10kW / 7.200BTU/h
3.00kW / 10.200BTU/h
ASHA09LG
2.50kW / 8.500BTU/h
3.20kW / 10.900BTU/h
ASHA12LG
3.40kW / 11.600BTU/h
4.00kW / 13.600BTU/h
ASHA14LG
4.00kW / 13.600BTU/h
5.00kW / 17.100BTU/h
ASHA24LF
For
ASHA24LF
ASHA30LF
For
ASHA30LF
ASHA24LF
7.10kW / 24,200BTU/h
8.10kW / 27,600BTU/h
ASHA30LF
8.00kW / 27,300BTU/h
9.00kW / 30,700BTU/h
ASHA18LE
5.20kW / 17.700BTU/h
6.30kW / 21.500BTU/h
ASHA18LE
For
ASHA18LE
R410A
R410A
14. 14
Our unique technology that achieved
top energy efficiency in the industry
Energy saving by automatic filter
cleaning function
Axial gap method
Computer-designed fan provides
a larger airflow than conventional models
Rotor plates are installed above and below electromagnets.
Features (Compared to conventional models)
This function allows an energy saving of more than 25% a year and maintains a
smooth airflow by preventing the filters from being clogged with dust.
Compact size with 1.5 more power output Self-driven method
increases rotating efficiency by 10%. Our electromagnetic field
simulation technology enables low vibration and low noise.
New air trunk, which provides a smooth airflow, and axial gap fan motor
increase the maximum airflow by 10% over that of conventional models.
CAE:Computer aided engineering
CAE
analysis
c
d
e
Thin copper wire
Area, which confronts magnetic attraction, is very narrow
Electromagnet
Rotor plate
Conventional motor Rotor is bounded by electromagnet.
Thin copper wire reduced
electric resistance.
Area which confronts magnetic attraction
is very wide and generates high power.
Rotor plate
Rotor plate
Electromagnet
New model
Axial gap fan motor enables nonconventional
high power & high efficiency
*1: Announced September 9, 2002.
In room air conditioner for the home
(Our company's investigation)
*2: Announced December 13, 2004.
As fan motor for air conditioner
(Our company's investigation)
*2
CEILING WALL TYPE
INVERTER
c
d
e
15. 15
b
a
Automatic filter cleaner
Energy saving Rank A cleared
with a margin to spare
If the energy saving effect is maintained,
filter cleaning once every two weeks is effective.
Two exhaustive sterilizing &
deodorizing countermeasures keep the
air in the room clean
If the energy saving effect is maintained,
filter cleaning once every two weeks is effective.
* Displays double the effect of a conventional optical
medium and retains its property for a long time to suck
in and remove approx. 99.99% of
cigarette odors and bacteria, etc.
Dirt & dust are thoroughly
sterilized by photo catalytic filter* a
Drives away bacteria and refreshes
the air by UV (ultraviolet rays)
illumination b
Sterilizing countermeasure
Since the filter is cleaned automatically, energy saving capability is displayed without
regard to the load on the air conditioner.
Entire filter is cleaned automatically in
approx. 2 minutes
Dimensions = H250 x W890 x D298mm
Handy Type
For
AWHZ 14/18LB
AWHZ 18/14LB
For
AWHZ 24LB
AWHZ 24LB
V-PAM
*1
8.50kW/29,000BTU/h
7.10kW/24,200BTU/h
AWHZ24LB
6.70kW / 22,900BTU/h
5.20kW / 17,700BTU/h
AWHZ18LB
6.00kW / 20,500BTU/h
4.20kW / 14,300BTU/h
AWHZ14LB
R410A
Antibacterial dust box
Removes dirt and dust by double brushes. Dust
collection is approx. twice that in the past. (our
company comparison)
Maintenance: Only throwing into a trash bin
once every two years
16. 16
Cooling/Heating capacities are based on the following conditions.
Cooling
Indoor temperature : 27O
C DB/19O
C WB
Outdoor temperature : 35O
C DB/(24O
C WB)
All air conditioners are single-phase types.
Specifications and design subject to change without notice for further improvement.
Please check with your dealer.
Heating
Indoor temperature : 20O
C DB
Outdoor temperature : 7O
C DB/6O
C WB
SPECIFICATIONS
Model No. Indoor Unit
Outdoor Unit
Capacity Class
Input Power
Capacity Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
BTU/h
BTU/h
V/ø/Hz
kW
kW
kW/kW
A
Power Consumption
EER
Running Current
Moisture Removal
Room Air Circulation (High)
Pints/h
Liter/h
C.F.M
(m3
/h)
H / W / D (mm)
kg(lbs)
H / W / D (mm)
kg(lbs)
Indoor Unit Dimensions
Weight
Outdoor Unit Dimensions
Weight
Refrigerant
Connection Method
AWHZ14LB
AOHZ14LB
14,000
230 / 1 / 50
14,300(3,100-18,100)
20,500(3,100-31,000)
4.20(0.90-5.30)
6.00(0.90-9.10)
1.02
1.35
4.12
4.44
4.50
5.90
4.5
(2.1)
500
(850)
250 x 899 x 298
13.5 (30)
578 x 790 x 300
39.0 (86)
R410A
Flare
AWHZ18LB
AOHZ18LB
18,000
230 / 1 / 50
17,700(3,100-20,100)
22,900(3,100-33,100)
5.20(0.90-5.90)
6.7(0.90-9.70)
1.58
1.63
3.29
4.11
6.90
7.20
6.0
(2.8)
500
(850)
250 x 899 x 298
13.5 (30)
578 x 790 x 300
39.0 (86)
R410A
Flare
AWHZ24LB
AOHZ24LB
24,000
230 / 1 / 50
24,200(3,100-27,000)
29,000(3,100-37,600)
7.10(0.90-8.00)
8.50(0.90-11.00)
2.21
2.35
3.21
3.62
9.70
10.30
6.4
(3.0)
518
(880)
250 x 899 x 298
14.0 (31)
830 x 900 x 330
62.0 (137)
R410A
Flare
CEILING WALL TYPE
Optimized Inverter Control
V-PAM inverter control reduces the effects of magnetic flux
and increases the maximum speed and efficiency of the
compressor by vector control technology. With this
technology, further miniaturization, higher efficiency, and
better performance are attained.
Temperature
V-PAM (Vector+I-PAM)
Inverter control
I-PAM (IPM*+PAM)
Inverter Control
I-PAM inverter control is a technology which reduces loss by adjusting
the current waveform to a better sine waveform. This promotes the
effective use of the input power supply to attain high performance.
In addition, the voltage is raised at the start of operation and
fast comfort is attainable by more powerful operation.
Setting
Temp.
Time
I-PAM Inverter
Conventional Inverter
This technology enables miniaturization and high performance of the
compressor.
It becomes more powerful with the newly developed
high efficient compressor motor control.
More compact than
conventional models
I-PAM inverter controlConventional inverter control
IPM*:Inteligent Power Module
Vector I-PAM
17. 17
Dimensions = H270 x W1,150 x D285mm
For AWG 30A/30A(HT)/30R(HT)
Compact outdoor unit
AWG 30R(HT)/30A(HT)/30A
Handy Type
For
AWG18/24A
AWG24/18A
For
AWG36A
AWG36A
For AWG18A/18R/
24A/24R/(HT)
AWG24R/24A/
18R/18A(HT)
AWG18A
AOG18A
18,000
240-220 / 1 / 50
18,400-18,100
-
5.40-5.30
-
2.18-2.12
-
2.48-2.50
-
9.4-9.8
-
4.3
(2.0)
447
(760)
270 x 1,150 x 285
16.0 (35)
643 x 840 x 336
66.0 (145)
R22
Flare
AWG24A
AOG24A
24,000
240-220 / 1 / 50
23,600-23,200
-
6.90-6.80
-
2.72-2.62
-
2.54-2.60
-
13.4-12.8
-
5.3
(2.5)
530
(900)
270 x 1,150 x 285
16.0 (35)
643 x 840 x 336
67.0 (147)
R22
Flare
AWG30A
AOG30A
30,000
240-220 / 1 / 50
28,800-27,500
-
8.20-8.05
-
3.20-3.07
-
2.56-2.62
-
15.5-14.9
-
6.4
(3.0)
559
(950)
270 x 1,150 x 285
16.0 (35)
900 x 900 x 350
84.0 (185)
R22
Flare
AWG36A
AOG36A
36,000
240-220 / 1 / 50
35,500-35,500
-
10.4-10.4
-
3.35-3.25
-
3.10-3.20
-
16.3-15.7
-
9.6
(4.5)
650
(1,100)
270 x 1,150 x 285
16.0 (35)
1,152 x 940 x 370
99.0 (218)
R22
Flare
AWG18A(HT)
AOGR18A(HT)
18,000
240-220 / 1 / 50
18,800-18,400
-
5.50-5.40
-
1.89-1.84
-
8.4-8.4
-
2.91-2.93
-
4.3
(2.0)
447
(760)
270 x 1,150 x 285
16.0 (35)
650 x 830 x 320
46.0 (101)
R22
Flare
AWG24A(HT)
AOGR24A(HT)
24,000
240-220 / 1 / 50
23,600-23,200
-
6.90-6.80
-
2.67-2.53
-
2.58-2.69
-
12.8-12.2
-
5.3
(2.5)
530
(900)
270 x 1,150 x 285
16.0 (35)
650 x 830 x 320
57.0 (125)
R22
Flare
AWG30A(HT)
AOG30A(HT)
30,000
240-220 / 1 / 50
28,000-27,500
-
8.20-8.05
-
3.00-2.85
-
2.73-2.83
-
13.6-13.3
-
6.4
(3.0)
559
(950)
270 x 1,150 x 285
18.0 (40)
900 x 900 x 350
79.0 (174)
R22
Flare
AWG18R(HT)
AOG18R(HT)
18,000
240-220 / 1 / 50
18,400-18,100
19,100-18,800
5.40-5.30
5.60-5.50
1.91-1.83
1.75-1.70
2.83-2.90
3.20-3.24
8.5-8.5
7.8-7.8
4.3
(2.0)
447
(760)
270 x 1,150 x 285
16.0 (35)
650 x 830 x 320
56.0 (123)
R22
Flare
AWG24R (HT)
AOG24R(HT)
24,000
240-220 / 1 / 50
23,200-22,500
26,600-25,900
6.80-6.60
7.80-7.60
2.66-2.53
2.68-2.53
2.56-2.61
2.91-3.00
12.2-12.0
12.4-12.0
5.3
(2.5)
530
(900)
270 x 1,150 x 285
16.0 (35)
650 x 830 x 320
60.0 (132)
R22
Flare
AWG30R(HT)
AOG30R(HT)
30,000
240-220 / 1 / 50
27,300-26,600
30,000-29,200
8.00-7.80
8.80-8.55
3.05-2.93
3.25-3.13
2.62-2.66
2.71-2.73
13.5-13.7
14.4-14.5
6.4
(3.0)
559
(950)
270 x 1,150 x 285
16.0 (35)
900 x 900 x 350
80.0 (176)
R22
Flare
AWG30A
8.20-8.05kW / 28,000-27,500BTU/h
AWG24A
6.90-6.80kW / 23,600-23,200BTU/h
AWG18A
5.40-5.30kW / 18,400-18,100BTU/h
8.00-7.80kW / 27,300-26,600BTU/h
8.80-8.55kW / 30,000-29,200BTU/h
AWG30R(HT)
8.20-8.05kW / 28,000-27,500BTU/h
AWG30A(HT)
AWG36A
10.4-10.4kW / 35,500-35,500BTU/h
6.90-6.80kW / 23,600-23,200BTU/h
AWG24A(HT)
5.40-5.30kW / 18,400-18,100BTU/h
5.60-5.50kW / 19,100-18,800BTU/h
AWG18R(HT)
5.50-5.40kW / 18,800-18,400BTU/h
AWG18A(HT)
6.80-6.60kW / 23,200-22,500BTU/h
7.80-7.60kW / 26,600-25,900BTU/h
AWG24R(HT)
CEILING WALL TYPE
18. 18
WINDOW TYPE
Dimensions = H428 x W710 x D877 mm
Front Panel Colour
Option
White
GoldBrown Wood grain
Dimensions = H349 x W457 x D581mm
Front Panel Colour White
AKG7A 2.10-2.10kW / 7,170-7,170BTU/h
AKG9A 2.55-2.50kW / 8,700-8,500BTU/h
Dimensions = H400 x W660 x D628mm
Front Panel Colour White
AFGA12A 3.40-3.30kW / 11,600-11,300BTU/h
ALG24R(HT) 6.25-6.15kW / 21,300-21,000BTU/h
6.45-6.35kW / 22,000-21,700BTU/h
ALG24A(HT) 6.90-6.75kW / 23,600-23,000BTU/h
ALG27A(HT) 7.90-7.70kW / 27,000-26,300BTU/h
ALG25D 7.10-6.90kW / 24,200-23,600BTU/h
ALG24R 6.25-6.15kW / 21,300-21,000BTU/h
6.35-6.25kW / 21,700-21,300BTU/h
ALGA19AAT 5.40-5.25kW / 18,500-17,900BTU/h
ALG22A
ALGA24A
6.35-6.30kW / 21,700-21,500BTU/h
6.90-6.75kW / 23,600-23,000BTU/h
ALGA27A 7.90-7.70kW / 27,000-26,300BTU/h
Cooling/Heating capacities are based on the following conditions.
Cooling
Indoor temperature : 27O
C DB/19O
C WB
Outdoor temperature : 35O
C DB/(24O
C WB)
All air conditioners are single-phase types.
Specifications and design subject to change without notice for further improvement.
Please check with your dealer.
Heating
Indoor temperature : 20O
C DB
Outdoor temperature : 7O
C DB/6O
C WB
SPECIFICATIONS
Model No.
Capacity Class
Input Power
Capacity Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
BTU/h
BTU/h
V/ø/Hz
kW
kW
kW/kW
A
Power Consumption
EER
Running Current
Moisture Removal
Room Air Circulation (High)
Pints/h
Liter/h
C.F.M
(m3
/h)
H / W / D (mm)
kg(lbs)
Dimensions
Weight
Refrigerant
Item ALGA19AAT
19,000
240-220/1/50
18,500-17,900
-
5.40-5.25
-
2.28-2.20
-
2.37-2.39
-
10.1-10.2
-
5.90
(2.8)
485
(825)
428x710x877
76.0 (167)
R22
Model No.
Capacity Class
Input Power
Capacity Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
BTU/h
BTU/h
V/ø/Hz
kW
kW
kW/kW
A
Power Consumption
EER
Running Current
Moisture Removal
Room Air Circulation (High)
Pints/h
Liter/h
C.F.M
(m3
/h)
H / W / D (mm)
kg(lbs)
Dimensions
Weight
Refrigerant
Item
ALG22A
22,000
240-220/1/50
21,700-21,500
-
6.35-6.30
-
2.67-2.54
-
2.38-2.48
-
13.4-12.5
-
6.95
(3.3)
565
(960)
428x710x877
79.0 (174)
R22
ALGA24A
24,000
240-220/1/50
23,600-23,000
-
6.90-6.75
-
2.95-2.82
-
2.38-2.33
-
14.7-14.4
-
8.00
(3.8)
590
(1,000)
428x710x877
80.0 (176)
R22
ALG24R
24,000
240-220/1/50
21,300-21,000
21,700-21,300
6.25-6.15
6.35-6.25
2.55-2.45
2.25-2.15
2.45-2.51
2.82-2.91
11.5-11.5
10.4-10.4
5.10
(2.4)
565
(960)
428x710x877
84.0 (185)
R22
ALG25D
25,000
240-220/1/50
24,200-23,600
-
7.10-6.90
-
3.05-2.92
-
2.33-2.36
-
14.5-14.3
-
8.00
(3.8)
675
(1,140)
428x710x877
95.0 (209)
R22
ALGA27A
27,000
240-220/1/50
27,000-26,300
-
7.90-7.70
-
3.15-3.08
-
2.51-2.50
-
16.0-15.5
-
8.50
(4.0)
610
(1,030)
428x710x877
94.0 (207)
R22
ALG24A(HT)
24,000
240-220/1/50
23,600-23,000
-
6.90-6.75
-
2.85-2.80
-
2.42-2.41
-
13.2-13.1
-
8.00
(3.8)
590
(1,000)
428x710x877
80.0 (176)
R22
ALG24R(HT)
24,000
240-220/1/50
21,300-21,000
22,000-21,700
6.25-6.15
6.45-6.35
2.55-2.40
2.28-2.15
2.45-2.56
2.83-2.95
11.5-11.5
10.7-10.2
5.10
(2.4)
565
(960)
428x710x877
82.0 (181)
R22
ALG27A(HT)
27,000
240-220/1/50
27,000-26,300
-
7.90-7.70
-
3.15-3.08
-
2.51-2.50
-
16.0-15.5
-
8.50
(4.0)
610
(1,030)
428x710x877
97.0 (214)
R22
AFGA12A
12,000
240-220/1/50
11,600-11,300
-
3.40-3.30
-
1.60-1.45
-
2.13-2.28
-
7.7-7.0
-
3.60
(1.7)
370
(630)
400x660x628
47.0 (104)
R22
20. 20
Drain water
lift-up
mechanism
Fresh-air intake
Outdoor
Indoor
Fresh Air
Optional drain water lift-up
mechanism offers more
flexible installation.
Long-life filter
Since the filter can be
simply detached, it can
be cleaned easily.
Filter
For
ABG36A/36R/
45A/45R/54A/54R
ABG54R/54A/
45R/45A/36R/36AFor
ABG30R
ABG30R
For
ABG30A(HT)
ABG30A(HT)
Dimensions = H240 x W1,660 x D700mm
ABG54R
14.1-13.9kW / 48,000-47,400BTU/h
15.8-15.4kW / 53,900-52,500BTU/h
ABG45R
12.7-12.4kW / 43,300-42,300BTU/h
13.7-13.4kW / 46,800-45,700BTU/h
ABG36R
10.5-10.3kW / 35,800-35,200BTU/h
10.7-10.5kW / 36,500-35,800BTU/h
ABG30R
8.60-8.30kW / 30,000-29,400BTU/h
9.50-9.30kW / 31,000-30,100BTU/h
Handy Type
ABG36A
10.5-10.3kW / 35,800-35,200BTU/h
ABG45A
12.7-12.4kW / 43,300-42,300BTU/h
ABG54A
14.1-13.9kW / 48,000-47,400BTU/h
ABG30A(HT)
8.80-8.60kW / 30,000-29,400BTU/h
Double swing automatic
5 steps selectable
Right and left
5 steps selectable
Up and down
Swing : Cooling and Dry mode
Steps
Swing : Heating and Fan mode
1
2
3
4
5
1
2
3
4
5
SPECIFICATIONS
Model No. Indoor Unit
Outdoor Unit
Capacity Class
Input Power
Capacity Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
BTU/h
BTU/h
V/ø/Hz
kW
kW
kW/kW
A
Power Consumption
EER
Running Current
Moisture Removal
Room Air Circulation (High)
Pints/h
Liter/h
C.F.M
(m3
/h)
H / W / D (mm)
kg(lbs)
H / W / D (mm)
kg(lbs)
Indoor Unit Dimensions
Weight
Outdoor Unit Dimensions
Weight
Refrigerant
Connection Method
Cooling/Heating capacities are based on the following conditions.
Cooling
Indoor temperature : 27O
C DB/19O
C WB
Outdoor temperature : 35O
C DB/(24O
C WB)
Specifications and design subject to change without notice for further improvement.
Please check with your dealer.Heating
Indoor temperature : 20O
C DB
Outdoor temperature : 7O
C DB/6O
C WB
ABG54R
AOG54R
54,000
415-380/3/50
48,000-47,400
53,900-52,500
14.1-13.9
15.8-15.4
5.25-5.20
5.30-5.30
2.69-2.67
2.98-2.91
8.9-9.0
9.0-9.1
11.7
(5.5)
1236
2,100
240x1,660x700
48.0 (106)
1,150x940x370
120.0 (264)
R22
Flare
ABG45R
AOG45R
45,000
415-380/3/50
43,300-42,300
46,800-45,700
12.7-12.4
13.7-13.4
4.45-4.35
4.50-4.45
2.85-2.85
3.04-3.01
8.3-8.1
8.4-8.4
11.7
(5.5)
1088
1,850
240x1,660x700
48.0 (106)
1,150x940x370
110.0 (243)
R22
Flare
ABG36R
AOG36R
36,000
415-380/3/50
35,800-35,200
36,500-35,800
10.5-10.3
10.7-10.5
4.10-4.00
3.50-3.45
2.56-2.58
3.06-3.04
7.0-7.0
6.3-6.2
8.5
(4.0)
976
(1,660)
240x1,660x700
48.0 (106)
1,150x940x370
100.0 (220)
R22
Flare
ABG30R
AOG30R
30,000
240-220/1/50
30,000-29,400
31,000-30,100
8.60-8.30
9.50-9.30
3.35-3.25
3.10-2.95
2.57-2.55
3.06-3.15
14.8-15.0
13.9-13.6
8.5
(4.0)
747
(1,270)
240x1,660x700
48.0 (106)
900x900x350
80.0 (176)
R22
Flare
ABG54A
AOG54A
54,000
415-380/3/50
48,000-47,400
-
14.1-13.9
-
5.25-5.20
-
2.69-2.67
-
8.9-9.0
-
11.7
(5.5)
1236
(2,100)
240x1,660x700
48.0 (106)
1,152x940x370
112.0 (246)
R22
Flare
ABG45A
AOG45A
45,000
415-380/3/50
43,300-42,300
-
12.7-12.4
-
4.45-4.35
-
2.85-2.85
-
8.3-8.1
-
11.7
(5.5)
1088
(1,850)
240x1,660x700
48.0 (106)
1,152x940x370
102.0 (225)
R22
Flare
ABG36A
AOG36A
36,000
415-380/3/50
35,800-35,200
-
10.5-10.3
-
4.10-4.00
-
2.56-2.58
-
7.0-7.0
-
8.5
(4.0)
976
(1,660)
240x1,660x700
48.0 (106)
1,152x940x370
94.0 (207)
R22
Flare
ABG30A(HT)
AOG30A(HT)
30,000
240-220/1/50
30,000-29,400
-
8.80-8.60
-
3.30-3.20
-
2.67-2.69
-
14.5-14.7
-
8.5
(4.0)
747
(1,270)
240x1,660x700
48.0 (106)
900x900x350
79.0 (174)
R22
Flare
CEILING (LARGE) TYPE
21. 21
ABG24R(HT)
AOG24R(HT)
24,000
240-220/1/50
23,200-22,500
26,600-25,900
6.80-6.60
7.80-7.60
2.78-2.60
2.68-2.53
2.45-2.54
2.91-3.00
12.8-12.4
12.8-12.4
5.3
(2.5)
530
(900)
199x990x655
30.0 (66)
650x830x320
60.0 (132)
R22
Flare
ABG18R(HT)
AOG18R(HT)
18,000
240-220/1/50
18,400-18,100
19,100-18,800
5.40-5.30
5.60-5.50
1.91-1.83
1.75-1.70
2.83-2.90
3.20-3.24
8.5-8.5
7.8-7.8
4.3
(2.0)
470
(800)
199x990x655
30.0 (66)
650x830x320
56.0 (123)
R22
Flare
ABG24A(HT)
AOGR24A(HT)
24,000
240-220/1/50
23,600-23,200
-
6.90-6.80
-
2.67-2.53
-
2.58-2.69
-
12.8-12.2
-
5.3
(2.5)
530
(900)
199x990x655
30.0 (66)
650x830x320
57.0 (125)
R22
Flare
ABG18A(HT)
AOGR18A(HT)
18,000
240-220/1/50
18,800-18,400
-
5.50-5.40
-
1.89-1.84
-
2.91-2.93
-
8.4-8.4
-
4.3
(2.0)
470
(800)
199x990x655
30.0 (66)
650x830x320
46.0 (101)
R22
Flare
ABG24R
AOG24R
24,000
240-220/1/50
22,500-22,200
26,300-25,900
6.60-6.50
7.70-7.60
2.70-2.60
2.59-2.49
2.44-2.50
2.97-3.05
13.0-12.5
12.5-12.0
7.4
(3.5)
529
(900)
199x990x655
30.0 (66)
643x840x336
68.0 (150)
R22
Flare
ABG18R
AOG18R
18,000
240-220/1/50
18,100-17,800
19,100-18,800
5.30-5.20
5.60-5.50
2.15-2.05
2.00-1.90
2.47-2.54
2.80-2.89
9.2-9.4
8.4-8.8
4.7
(2.2)
470
(800)
199x990x655
30.0 (66)
643x840x336
68.0 (150)
R22
Flare
ABG24A
AOG24A
24,000
240-220/1/50
23,600-23,200
-
6.90-6.80
-
2.85-2.75
-
2.42-2.47
-
13.6-13.3
-
7.4
(3.5)
529
(900)
199x990x655
30.0 (66)
643x840x336
68.0 (150)
R22
Flare
ABG18A
AOG18A
18,000
240-220/1/50
18,400-18,100
-
5.40-5.30
-
2.15-2.05
-
2.51-2.59
-
9.2-9.4
-
4.6
(2.2)
470
(800)
199x990x655
30.0 (66)
643x840x336
66.0 (146)
R22
Flare
Dimensions = H199 x W990 x D655mm
Handy Type
For
ABG18A/
18R/24A/24R
ABG24R/
24A/18R/18A
For
ABG18A/
18R/24A/24R(HT)
ABG24R/
24A/18R/18A(HT)
Slim & Compact design
Symmetrical, slim and compact design
990
(unit:mm)
199
655
Super vane
Double swing automatic
A combination of up/down
and right/left directional swing
allows three-dimensional air
direction control.
Cool or warm air is delivered quickly to
every corner of the room by double flap
"super vane" which strengthens the air
flow with a newly developed special flap
shape.
ABG24A(HT)
6.90-6.80kW / 23,600-23,200BTU/h
ABG18A(HT)
5.50-5.40kW / 18,800-18,400BTU/h
ABG24A
6.90-6.80kW / 23,600-23,200BTU/h
5.40-5.30kW / 18,400-18,100BTU/h
ABG18A
5
5
4
3
2
1
2 4
Right and Left Swing
5 steps selectable
Up and Down Swing
7 steps selectable
1
6
7
3
Swing : Cooling,
Dry and Fan mode
Steps
Swing : Heating and
Fan mode
ABG24R(HT)
6.80-6.60kW / 23,200-22,500BTU/h
7.80-7.60kW / 26,600-25,900BTU/h
ABG18R
5.30-5.20kW / 18,100-17,800BTU/h
5.60-5.50kW / 19,100-18,800BTU/h
ABG24R
6.60-6.50kW / 22,500-22,200BTU/h
7.70-7.60kW / 26,300-25,900BTU/h
ABG18R(HT)
5.40-5.30kW / 18,400-18,100BTU/h
5.60-5.50kW / 19,100-18,800BTU/h
FLOOR/CEILING UNIVERSAL TYPE
22. 22
SPECIFICATIONS
Model No. Indoor Unit
Outdoor Unit
Capacity Class
Input Power
Capacity Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
BTU/h
BTU/h
V/ø/Hz
kW
kW
kW/kW
A
Power Consumption
EER
Running Current
Moisture Removal
Room Air Circulation (High)
Pints/h
Liter/h
C.F.M
(m3
/h)
H / W / D (mm)
kg(lbs)
H / W / D (mm)
kg(lbs)
Indoor Unit Dimensions
Weight
Outdoor Unit Dimensions
Weight
Refrigerant
Connection Method
Grille
Cooling/Heating capacities are based on the following conditions.
Cooling
Indoor temperature : 27O
C DB/19O
C WB
Outdoor temperature : 35O
C DB/(24O
C WB)
All air conditioners are single-phase types.
Specifications and design subject to change without notice for further improvement.
Please check with your dealer.
Heating
Indoor temperature : 20O
C DB
Outdoor temperature : 7O
C DB/6O
C WB
AUG36A
AOG36A
36,000
415-380/3/50
35,800-35,200
-
10.5-10.3
-
3.80-3.70
-
2.76-2.78
-
6.5-6.5
-
10.6
(5.0)
875
(1,500)
296x830x830
40.0 (88)
1,152x940x370
94.0 (207)
R22
UTG-UEGA-W
Flare
AUG30A(HT)
AOG30A(HT)
30,000
240-220/1/50
30,000-29,000
-
8.80-8.60
-
3.40-3.30
-
2.59-2.61
-
16.3-15.8
-
8.5
(4.0)
706
(1,200)
246x830x830
34.0 (75)
900x900x350
84.0 (185)
R22
UTG-UEGA-W
Flare
AUG25A(HT)
AOGA25A(HT)
25,000
240-220/1/50
24,200-23,900
-
7.10-7.00
-
2.83-2.65
-
2.51-2.64
-
13.7-13.0
-
5.3
(2.5)
647
(1,100)
246x830x830
34.0 (75)
650x830x320
57.0 (125)
R22
UTG-UEGA-W
Flare
AUG18R
AOG18R
18,000
240-220/1/50
17,100-16,600
18,600-18,100
5.00-4.85
5.45-5.30
1.85-1.75
1.95-1.85
2.70-2.77
2.79-2.86
8.0-8.5
8.5-9.0
4.4
(2.1)
383
(650)
235x580x580+70
18.0 (40)
530x750x250
56.0 (123)
R22
UTG-UDGD-W
Flare
AUG12R
AOG12R
12,000
240-220/1/50
12,300-12,100
14,000-13,700
3.60-3.55
4.10-4.00
1.34-1.26
1.28-1.20
2.69-2.82
3.20-3.33
6.1-5.9
5.8-5.7
3.5
(1.6)
324
(550)
235x580x580+70
18.0 (40)
530x750x250
37.0 (82)
R22
UTG-UDGD-W
Flare
AUG18A(HT)
AOGA18A(HT)
18,000
240-220/1/50
17,400-16,900
-
5.10-4.95
-
1.90-1.80
-
2.68-2.75
-
8.2-8.5
-
4.4
(2.1)
383
(650)
235x580x580+70
18.0 (40)
650x830x320
46.0 (101)
R22
UTG-UDGD-W
Flare
AUG12A
AOG12A
12,000
240-220/1/50
12,600-12,500
-
3.70-3.65
-
1.44-1.36
-
2.57-2.68
-
6.5-6.3
-
3.5
(1.6)
324
(550)
235x580x580+70
18.0 (40)
530x750x250
32.0 (71)
R22
UTG-UDGD-W
Flare
Dimensions = (Body ) H235 x W580 x D580+70mm
(Panel ) H35 x W650 x D650mm
AUG18R/18A(HT)
For
AUG18A(HT)/18R
For
AUG 12A/12R
AUG 12R/12A
4-way airflow system
2-way3-way4-way
4 steps swing Steps
Swing
Operation
On time 8:00~12:00
On time14:00~19:00
Sun Mon Tue Wed Thu Fri Sat
0
618
12
Weekly timer (AUG25-54A/R)
Three kinds of timer setting
(OFF/ON/WEEKLY) are possible.
Function of weekly timer.
Setting of different on-off times day by day.
Setting of on-off times twice a day.
Setting of time in 5-minute steps.
Timer operation for a reserved day can be cancelled in
advance by pushing the “DAY OFF” button.
Time setting can be left until the next day.
Auto airflow direction
& auto swing
Handy Type
AUG12R
3.60-3.55kW / 12,300-12,100BTU/h
4.10-4.00kW / 14,000-13,700BTU/h
AUG18R
5.00-4.85kW / 17,100-16,600BTU/h
5.45-5.30kW / 18,600-18,100BTU/h
AUG12A
3.70-3.65kW / 12,600-12,500BTU/h
AUG18A(HT)
5.10-4.95kW / 17,400-16,900BTU/h
CASSETTE (COMPACT) TYPE
24. 24
ARG 60A/ ARG 60R
Pursuance of amenity performance
1.Wired Remote Controller with Thermo Sensor
1 2 3
Room temperature
sensor selection
WEEKLY timer
Temperature SET BACK timer
Group control system
Child lock
Dual remote controllers
<optional parts>
AUTO restart
Energy saving
Auto changeover <for heating>
Hot start <for heating>
Various remote controllers and sensors can be selected.
2.Simple Remote Controller (Optional Parts)
Long life filter (Optional Parts)
Output port (Built-in)
Schedule bar display makes confirmation of the operation
time easy. The power can be switched ON/OFF even during
timer setting. Operation flexibility has been enhanced.
Use of the Weekly Timer only in the morning and
turning ON manually by the user in the evening, like
the repeat timer function of the current model, is
possible. The day’s schedule is displayed.
Example
Weekly timer (ARG60A/R)
The temperature can be changed according to
the WEEKLY TIMER.
Favorite temperature control allows amenity and
energy-saving operations.
Temperature SET BACK timer (New function)
SU MO TU WE TH FR SA
7
3 126 9 15 18 21
Example of setting display
Setting: Wednesday, 8:00 - 20:00.
SU MO TU WE TH FR SA
7
3 126 9 15 18 21
Display after timer is set
0 3 6 9 12 15 18 21
24ºC
At "WEEKLY timer"+
"SET BACK timer" setting
0 3 6 9 12 15 18 210 3 6 9 12 15 18 21
28ºC
24ºC28ºC24ºC
Example of setting display
SU MO TU WE TH FR SA
3 126 9 15 18 21
Setting: Sunday - Saturday,13:00 - 15:00, 28ºC
3.Remote Sensor (Optional Parts)
SPECIFICATIONS
Model No. Indoor Unit
Outdoor Unit
Capacity Class
Input Power
Capacity Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
BTU/h
BTU/h
V/ø/Hz
kW
kW
kW/kW
A
Power Consumption
EER
Running Current
Moisture Removal
Room Air Circulation (High)
Pints/h
Liter/h
C.F.M
(m3
/h)
H / W / D (mm)
kg(lbs)
H / W / D (mm)
kg(lbs)
Indoor Unit Dimensions
Weight
Outdoor Unit Dimensions
Weight
Refrigerant
Connection Method
Specifications and design subject to change without notice
for further improvement. Please check with your dealer.
ARG90E/90T
ARG60A/60R
Cooling/Heating capacities are based on the following conditions.
Cooling
Indoor temperature : 27O
C DB/19O
C WB
Outdoor temperature : 35O
C DB/(24O
C WB)
Heating
Indoor temperature : 20O
C DB
Outdoor temperature : 7O
C DB/6O
C WB
*Air volume of ARG90E/90T models is given, when external static pressure is 20mm Aq (196Pa).
*Air volume of ARG60A/60R/ models is given, when external static pressure is 100Pa.
ARG90E
AOG90E
90,000
415-380/3/50
86,700-86,700
-
25.4-25.4
-
10.5-10.5
-
2.42-2.42
-
17.0-17.0
-
16.0
(7.5)
2537
(4,300)
450x1,550x700
85.0 (187)
1,380x1,300x650
243.0 (535)
R407C
Flare(Small), Flange(Large)
ARG90T
AOG90T
90,000
415-380/3/50
86,700-84,700
100,500-98,500
25.4-24.8
29.5-28.9
12.5-12.2
12.5-12.2
2.03-2.03
2.36-2.37
19.5-19.5
19.5-19.5
16.0
(7.5)
2537
(4,300)
450x1,550x700
85.0 (187)
1,380x1,300x650
245.0 (539)
R407C
Flare(Small), Flange(Large)
ARG60R
AOG60R
60,000
415-380/3/50
58,000-56,000
62,100-61,000
17.0-16.4
18.2-17.8
6.00-5.90
5.25-5.05
2.83-2.78
3.47-3.52
9.8-9.8
8.7-8.7
13.7
(6.5)
2119
(3,600)
400x1,050x500
50.0 (110)
1,355x940x370
129.0 (284)
R22
Flare
ARG60A
AOG60A
60,000
415-380/3/50
58,000-56,000
-
17.0-16.4
-
5.90-5.80
-
2.88-2.83
-
9.8-9.8
-
13.7
(6.5)
2119
(3,600)
400x1,050x500
50.0 (110)
1,355x940x370
121.0 (267)
R22
Flare
DUCT TYPE
25. 25
ARG 90T/ ARG 90E
Dimensions = H400 x W1,050 x D500mm
Wired Type
(With Weekly/Setback Timer)
Realizing light weight corresponding to compact size of
basic chassis and considerable reduction of materials.
Easy installation (Compact size & Light weight)
Weight : 50kg
400mm
500mm1,050mm
Carrying-in example in the ceiling
500mm
400mm
750mm
550mm
Restriction for space when being
carried into the ceiling for replacement
(Ceiling intake grille)
Ultra thin duct air conditioner for very low ceilings
Dimensions = H450 x W1,550 x D700mm
Wired Type
(With Weekly Timer)
High static pressure
duct type for ARG 90E/90T
ARG 90T/90E
Air Flow
4,300(m3/h)
Pa
m
3
h
ARG 90T/90E
200 (MAX.300)
4,300
Example of room temperature sensor selection
Remote Sensor
in the bedroom
(effective at night)
Wired Remote
Controller
Remote Sensor
(Option)
THERMO
SENSOR
Indoor unit
The detection point can be freely changed.
Day Night
in the living room
(effective during the day)
Remote controller
ARG60A
17.0-16.4kW / 58,000-56,000BTU/h
ARG60R
17.0-16.4kW / 58,000-56,000BTU/h
18.2-17.8kW / 62,100-61,000BTU/h
ARG90E
25.4-25.4kW / 86,700-86,700BTU/h
ARG90T
25.4-24.8kW / 86,700-84,700BTU/h
29.5-28.9kW / 100,500-98,500BTU/h
R410A
26. 26
Air intake possible from
two directions
Slim ultra thin indoor unit
Air outflow opening Air intake opening
RearBottom
27cm
Installation example
Duct
Dimensions = H270 x W1,210 x D700mm
For
ARG25A/25R
ARG25R/25A
For
ARG30A(HT)/30R
ARG30R/30A(HT)
For
ARG36A/36R/45A/45R
ARG45R/45A/36R/36A
Wired Type
(With Weekly Timer)
For
ARG25A(HT)
ARG25A(HT)
7.85-7.60kW / 26,800-25,900BTU/h
9.5-9.3kW / 32,400-31,700BTU/h
ARG25R
7.05-6.95kW / 24,100-23,700BTU/h
ARG30R
8.6-8.3kW / 29,400-28,300BTU/h
10.7-10.5kW / 36,500-35,800BTU/h
ARG36R
10.5-10.3kW / 35,800-35,200BTU/h
13.7-13.4kW / 46,800-45,700BTU/h
ARG36A
10.5-10.3kW / 35,800-35,200BTU/h
ARG45A
12.7-12.4kW / 43,300-42,300BTU/h
ARG45R
12.7-12.4kW / 43,300-42,300BTU/h
ARG 25A/25R/30R/36A/36R/45A/45R
ARG25A(HT)
7.10-7.00kW / 24,200-23,900BTU/h
ARG30A(HT)
8.80-8.60kW / 30,000-29,200BTU/h
ARG25A
7.10-7.00kW / 24,200-23,900BTU/h
SPECIFICATIONS
Model No. Indoor Unit
Outdoor Unit
Capacity Class
Input Power
Capacity Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
BTU/h
BTU/h
V/ø/Hz
kW
kW
kW/kW
A
Power Consumption
EER
Running Current
Moisture Removal
Room Air Circulation (High)
Pints/h
Liter/h
C.F.M
(m3
/h)
H / W / D (mm)
kg(lbs)
H / W / D (mm)
kg(lbs)
Indoor Unit Dimensions
Weight
Outdoor Unit Dimensions
Weight
Refrigerant
Connection Method
Cooling/Heating capacities are based on the following conditions.
Cooling
Indoor temperature : 27O
C DB/19O
C WB
Outdoor temperature : 35O
C DB/(24O
C WB)
All air conditioners are single-phase types.
Specifications and design subject to change without notice for further improvement.
Please check with your dealer.
Heating
Indoor temperature : 20O
C DB
Outdoor temperature : 7O
C DB/6O
C WB
ARG14U
AOG14U
14,000
230/1/50
13,700
16,000
4.0
4.7
1.42
1.35
2.82
3.48
6.30
6.00
3.2
(1.5)
377
(640)
217x953x595
25.0 (55)
530x750x250
35.0 (77)
R410A
Flare
ARG12U
AOG12U
12,000
230/1/50
11,900
13,600
3.5
4.0
1.24
1.21
2.82
3.31
5.50
5.40
2.5
(1.2)
294
(500)
217x953x595
25.0 (55)
530x750x250
34.0 (75)
R410A
Flare
ARG18A(HT)
AOGA18A(HT)
18,000
240-220/1/50
18,400-18,100
-
5.40-5.30
-
2.00-1.90
-
2.70-2.79
-
8.9-9.0
-
3.5
(1.6)
565
(960)
217x953x595
25.0 (55)
650x730x320
46.0 (92.0)
R22
Flare
ARG18A
AOG18A
18,000
240-220/1/50
18,400-18,100
-
5.40-5.30
-
2.20-2.10
-
2.45-2.52
-
9.5-9.9
-
3.5
(1.6)
565
(960)
217x953x595
25.0 (55)
643x840x336
66.0 (146)
R22
Flare
ARG14F
AOG14F
14,000
230/1/50
14,300
-
4.2
-
1.39
-
3.02
-
6.30
-
3.2
(1.5)
377
(640)
217x953x595
25.0 (55)
530x750x250
35.0 (77)
R410A
Flare
ARG12F
AOG12F
12,000
230/1/50
11,900
-
3.5
-
1.24
-
2.82
-
5.50
-
2.5
(1.2)
294
(500)
217x953x595
25.0 (55)
530x750x250
34.0 (75)
R410A
Flare
ARG9U
AOG9U
9,000
230/1/50
9,200
10,600
2.7
3.1
0.96
0.96
2.81
3.23
4.40
4.50
2.1
(1.0)
247
(420)
217x663x595
18.0 (40)
530x750x250
30.0 (66)
R410A
Flare
ARG7U
AOG7U
7,000
230/1/50
7,300
8,400
2.2
2.5
0.76
0.76
2.83
3.22
3.60
3.60
1.7
(0.8)
200
(340)
217x663x595
18.0 (40)
530x750x250
28.0 (62)
R410A
Flare
ARG9F
AOG9F
9,000
230/1/50
9,500
-
2.8
-
0.99
-
2.83
-
4.60
-
2.1
(1.0)
247
(420)
217x663x595
18.0 (40)
530x750x250
27.0 (60)
R410A
Flare
ARG7F
AOG7F
7,000
230/1/50
7,300
-
2.2
-
0.76
-
2.83
-
3.70
-
1.7
(0.8)
200
(340)
217x663x595
18.0 (40)
530x750x250
27.0 (60)
R410A
Flare
DUCT TYPE
28. 28
You can select any type of
air conditioners as you like
to suit the atmosphere
of your room.
WALL MOUNTED TYPE (Small Size)
ASGG18/24LF
FLOOR TYPE
AGGG09/12/14LV
COMPACT CASSETTE TYPESLIM DUCT TYPE
FLOOR/CEILING UNIVERSAL TYPE
AUGG07/09/12/14/18LVARGG07/09/12/14/18LL
ABGG14/18/24LV
WALL MOUNTED TYPE
ASGG07/09/12LJ
Space-saving installation
Multiple indoor units can be connected to high performance compact
outdoor unit with DC compressor mounted. Installation area is
reduced drastically compared with single type.
6 types, 20 models are lined up in the capacity range from 2kW to 7kW.
The wide-ranging needs can be met from the private room of
residence or hotel to large shop.
AOGG18LAC2
AOGG18/24LAT3/AOGG30LAT4
AOGG18LAC2 /18LAT3
/24LAT3/30LAT4
Flexible Installation
Maximum Piping Length (Each Unit)
20m (AOGG18LAC2)
25m (AOGG18/24LAT3/AOGG30LAT4)
15m (AOGG18LAC2 /18LAT3 /
24LAT3/30LAT4)
Maximum Height
Up to max. piping length 70m (AOYG30LAT4), max.
height difference 15m can be supported. This multi
type can be installed at large-size residence or
multiple floors.
30m (AOGG18LAC2),
50m (AOGG18/24LAT3),
70m (AOGG30LAT4)
AOGG18LAC2
AOGG18/24LAT3
AOGG30LAT4
Total Piping Length:
Wide range of indoor units
with various models
9.6kW/32,800BTU/h
AOGG30LAT4
8.0kW/27,300BTU/h
5.6kW/19,100BTU/h
AOGG18LAC2
5.0kW/17,100BTU/h
6.8kW/23,200BTU/h
AOGG18LAT3
5.4kW/18,400BTU/h
8.0kW/27,300BTU/h
AOGG24LAT3
6.8kW/23,200BTU/h
MULTI-TYPE SYSTEM
INVERTER
R410A
ASGG18/24LF
ASGG07/09/12LJ
kW Indoor Unit
WALL MOUNTED TYPE
AGGG09/12/14LV FLOOR TYPE
ABGG14/18/24LV
FLOOR/CEILING UNIVERSAL TYPE
ARGG07/09/12/14/18LL
AUGG07/09/12/14/18LV CASSETTE (COMPACT) TYPE
2 Rooms (18 type) 1 O.U. to 2 I.U.
3 Rooms (18 type) 1 O.U. to 2-3 I.U.
3 Rooms (24 type) 1 O.U. to 2-3 I.U.
4 Rooms (30 type) 1 O.U. to 3-4 I.U.
AOGG18LAC2
AOGG18LAT3
AOGG24LAT3
AOGG30LAT4
Total capacity of indoor units 4.0-7.0kW can be connected
Total capacity of indoor units 4.0-8.8kW can be connected
Total capacity of indoor units 4.0-10.6kW can be connected
Total capacity of indoor units 7.9-14.4kW can be connected
AOGG18LAC2
AOGG18LAT3
AOGG24LAT3
AOGG30LAT4
AOGG18LAC2 AOGG18LAT3 AOGG24LAT3 AOGG30LAT4
2.0
2.5
3.5
5.0
7.0
2.5
3.5
4.0
2.0
2.5
3.5
4.0
5.0
4.0
5.0
2.0
2.5
3.5
4.0
5.0
SLIM DUCT TYPE
29. 29
AOH24U/24F/19U/19F
For
AOH19F/19U/24F/24U
Outdoor Unit Indoor Units
COMP.
A
COMP.
B B
A
(ASH9FMBD x2)
AOH19F
(ASH9UMBD x2)
AOH19U
2.85kW / 9,700BTU/h
2.80kW / 9,600BTU/h
3.25kW / 11,100BTU/h
(ASH12FMBD x2)
AOH24F
(ASH12UMBD x2)
AOH24U
3.50kW / 11,900BTU/h
3.50kW / 11,900BTU/h
4.10kW / 14,000BTU/h
Cooling/Heating capacities are based on the following conditions.
Cooling
Indoor temperature : 27O
C DB/19O
C WB
Outdoor temperature : 35O
C DB/(24O
C WB)
All air conditioners are single-phase types.
Specifications and design subject to change without notice for further improvement.
Please check with your dealer.
Heating
Indoor temperature : 20O
C DB
Outdoor temperature : 7O
C DB/6O
C WB
Power Consumption
Model No.
Capacity Class
Input Power V/ø/Hz
Heating
Cooling
Cooling
Heating
Cooling
Heating
Capacity
Moisture Removal
Pints/h
(liter/h)
kW
A
Room Air Circulation(High)
C.F.M
(m3
/h)
kW
BTU/h
BTU/h
Indoor Unit
Outdoor Unit
EER
Running Current
kW/kW
Heating
Cooling
Cooling
Heating
Wall Mounted, Floor/Ceiling Universal, Cassette, Duct
AOGG18LAC2
18,000
230/1/50
17,100
19,100
5.00
5.60
1.56
1.41
3.21
3.97
8.70
9.20
-
-
540x790x290
38.0 (84)
R410A
Flare
AOGG18L2
18,000
230/1/50
18,400
23,200
5.40
6.80
1.35
1.62
4.00
4.20
5.90
7.10
-
-
AOGG18LAT3
R410A
Flare
700x900x330
55.0 (121)
AOGG18L3
AOGG24LAT3
24,000
230/1/50
23,200
27,300
6.80
8.00
1.94
2.00
3.50
4.00
8.50
8.80
-
-
R410A
Flare
700x900x330
55.0 (121)
AOGG24L3
30,000
230/1/50
27,300
32,800
8.00
9.60
2.22
2.40
3.60
4.00
9.70
10.50
-
-
AOGG30LAT4
R410A
Flare
830x900x330
68.0 (150)
AOGG30L4
9,700
-
2.85
-
1.02
-
2.79
-
4.60
-
2.1
(1.0)
19,400
-
5.70
-
1.89
-
3.02
-
8.60
-
4.3
(2.0)
9,600
11,100
2.80
3.25
0.99
1.03
2.83
3.16
4.60
4.60
2.1
(1.0)
19,100
22,200
5.60
6.50
1.86
1.90
3.01
3.42
8.60
8.60
4.3
(2.0)
ASH9FMBDx2ASH9FMBD
AOH19F AOH19U AOH24F AOH24U
AOH19FSCV2
19,000
230/1/50 230/1/50 230/1/50 230/1/50
AOH19USCV2
19,000
AOH24FSBV2
24,000
AOH24USBV2
24,000
ASH9UMBDx2ASH9UMBD
11,900
-
3.50
-
1.32
-
2.65
-
5.90
-
2.8
(1.3)
23,900
-
7.00
-
2.49
-
2.81
-
11.20
-
5.5
(2.6)
ASH12FMBD ASH12FMBDx2 ASH12UMBDx2
11,900
14,000
3.50
4.10
1.30
1.38
2.69
2.97
5.80
6.10
2.8
(1.3)
23,900
28,000
7.00
8.20
2.55
2.55
2.75
3.22
11.20
11.40
5.5
(2.6)
257x808x187
8.0 (18)
257x808x187
8.0 (18)
257x808x187
8.0 (18)
257x808x187
8.0 (18)
700x900x330
61.0 (134)
R410A
Flare Flare Flare Flare Flare Flare Flare Flare
R410A
700x900x330
63.0 (139)
R410A
700x900x330
68.0 (150)
R410A
700x900x330
70.0 (154)
ASH12UMBD
H / W / D (mm)
kg(lbs)
H / W / D (mm)
kg(lbs)
Indoor Unit Dimensions
Weight
Outdoor Unit Dimensions
Weight
Refrigerant
Connection Method
(ASGG07/09/12LJ) 560/600/660
(ASGG18/24LF) 900/1,100
(AGGG09/12/14/18/24LV) 530/600/650/640/780
(AUGG07/09/12/14/18LV) 540/540/610/680/750
(ARGG07/09/12/14/18LL) 550/600/650/800/940
(ASGG07/09/12LJ) 280X790X203, (ASGG18/24LF) 320X998X228,
(AGGG09/12/14LV) 600x740x200, (ABGG14/18LV) 199x990x655,
(AUGG07/09/12/14/18LV) 245x570x570,
(ARGG07/09/12/14LL) 198X700X620, (ARGG18LL) 198X900X620
(ASGG07/09/12LJ) 8(17.6), (ASGG18LF) 14(30.8), (ASGG24LF) 16(35.2)
(AGGG09/12/14LV) 14(30.7), (ABGG14/18LV) 27(60),
(AUGG07/09/12/14/18LV) 15(33.1)
(ARGG07/09/12/14LL) 19(41.8), (ARGG18LL) 23(50.6)
306
(520)
306x2
(520)x2
277
(470)
277x2
(470x2)
306
(520)
306x2
(520x2)
325
(550)
325x2
(550x2)
MULTI-TYPE SYSTEM
R410A R410A
R410A R410A
30. 30
Model No.Item
W
mm
mm
kW
Pints/h
(liter/h)
C.F.M
(m3/h)
V
o| /Hz
BTU/h
Cooling
Heating
Cooling
Heating
Capacity
Moisture Removal
High
Med
Low
Room Air
Circulation
Fan Motor Output
Phase-Frequency
Power Supply
Height
Width
Depth
Dimensions
kg(lbs)Net Weight
Connection Method
Connection Pipe Size(Small o| /Large o| )
Cooling/Heating capacities are based on the following conditions.
Cooling
Indoor temperature : 27O
C DB/19O
C WB
Outdoor temperature : 35O
C DB/(24O
C WB)
Heating
Indoor temperature : 20O
C DB
Outdoor temperature : 7O
C DB/6O
C WB
SPECIFICATIONS
8.60-8.80
8.80-9.10
29,400-30,000
30,000-31,000
6.3
(3.0)
970
(1,650)
910
(1,550)
790
(1,350)
220-240
1/50
275
270
1,210
700
43(95)
9.53/15.88
Flare
ARXA30TATA
6.95-7.05
7.60-7.85
23,700-24,100
25,900-26,800
5.3
(2.5)
940
(1,600)
850
(1,450)
750
(1,280)
220-240
1/50
70
270
1,210
700
43(95)
9.53/15.88
Flare
ARXA25TATA
12.40-12.70
13.40-13.70
42,500-43,500
46,000-47,000
11.6
(5.5)
1,090
(1,850)
980
(1,660)
840
(1,430)
220-240
1/50
160
240
1,660
700
48(106)
9.53/19.05
Flare
ABGA45TATA
10.30-10.50
10.50-10.70
35,200-36,000
36,000-36,500
8.5
(4.0)
980
(1,660)
880
(1,500)
750
(1,270)
220-240
1/50
160
240
1,660
700
48(106)
9.53/19.05
Flare
ABGA36TATA
8.60-8.80
8.80-9.10
29,400-30,000
30,000-31,000
8.5
(4.0)
750
(1,270)
660
(1,120)
510
(860)
220-240
1/50
160
240
1,660
700
48(106)
9.53/15.88
Flare
ABGA30TATA
6.50-6.60
7.60-7.70
22,200-22,500
25,900-26,300
7.2
(3.4)
530
(900)
460
(780)
390
(660)
220-240
1/50
40
199
990
655
30(66)
9.53/15.88
Flare
ABGA24TATA
5.20-5.30
5.50-5.60
17,800-18,100
18,800-19,100
4.6
(2.2)
470
(800)
400
(680)
330
(560)
220-240
1/50
30
199
990
655
28(62)
9.53/15.88
Flare
ABGA18TATA
12.40-12.70
13.40-13.70
42,300-43,400
45,800-46,800
12.7
(6.0)
970
(1,650)
850
(1,450)
710
(1,200)
220-240
1/50
90
296
830
830
40(88)
9.53/19.05
Flare
AUGA45TATA
10.30-10.50
10.50-10.70
35,200-36,000
35,800-36,500
10.6
(5.0)
880
(1,500)
770
(1,300)
650
(1,100)
220-240
1/50
90
296
830
830
40(88)
9.53/19.05
Flare
AUGA36TATA
8.60-8.80
8.80-9.10
29,400-30,000
30,000-31,100
6.3
(3.0)
750
(1,270)
630
(1,070)
520
(880)
220-240
1/50
90
296
830
830
38(84)
9.53/15.88
Flare
AUGA30TATA
6.95-7.05
7.60-7.85
23,700-24,100
25,900-26,000
5.3
(2.5)
690
(1,170)
570
(970)
450
(770)
220-240
1/50
90
296
830
830
38(84)
9.53/15.88
Flare
AUGA25TATA
4.85-5.00
-5.30-5.45
19,000-19,900
21,000-21,600
4.4
(2.1)
380
(650)
320
(550)
290
(490)
220-240
1/50
14
235
580
580+70
18(40)
9.53/15.88
Flare
AUG18TATA
BIG MULTI TYPE SYSTEMS
Simultaneous Operation
Features of System Operations
Simultaneous Operating System suitable for large spaces such as
offices, lobbies and waiting rooms of high-rise buildings.
One controller can simultaneously control
cooling or heating by 2~4 indoor units.
45,000
36,000
30,000
(25,000)
24,000
18,000
Long piping for high-rise buildings
Various combinations of indoor
unit types and capacities
Centralized control by wired remote
controller with weekly timer
Cooling & heating at low
outdoor temperatures
Space saving
Easy installation
Indoor Unit Lineup
CASSETTECASSETTE
(COMPACT) CAPACITY
(BTU)
DUCT
FLOOR/CEILING
UNIVERSAL CEILING(LARGE)
Outdoor units can be grouped together in a row.
Chargeless 30m
Heightdifference:30mmax.
Actual pipe length : 50m max.
Indoor unit Indoor unit Indoor unit Indoor unit
Outdoor unit
Refrigerant System
Wired remote
controller
UTB-YUB (option)
UTB-YUB
Gas pipe
Liquid pipe
Separation tube
Outdoor unit Indoor unit
R407C
Indoor Unit Combinations
3 INDOOR UNITS
Outdoor Unit
Indoor UnitsIndoor Units
24,000+24,000+45,000(BTU/h)
30,000+30,000+30,000(BTU/h)
18,000+30,000+45,000(BTU/h)
18,000+36,000+36,000(BTU/h)
24,000+30,000+36,000(BTU/h)
Indoor Units
4INDOOR UNITS
24,000+24,000+24,000+24,000(BTU/h)
18,000+18,000+18,000+36,000(BTU/h)
18,000+24,000+18,000+30,000(BTU/h)
2 INDOOR UNITS
Outdoor Unit
45,000+45,000(BTU/h)
Indoor Units Indoor Units
Outdoor Unit
Indoor Units Indoor UnitsIndoor Units Indoor Units
Specifications and design subject to change without notice for further improvement.
Please check with your dealer.
31. 31
Model No.
kW
Total
Capacity
Power Supply
Cooling
Heating
A
A
Total
Ampacity
Starting Current
Cooling
Heating
Cooling
Heating
Cooling
Heating
BTU/h
Cooling
Heating
V
o| /Hz
kW
Total
Input Watts
ºC
Operation
(Outdoor)
Cooling
Heating
m
Pipe
Liquid/GasSize
mmDimensions
Height
Width
Depth
Net
kg(lbs)Weights
db(A)Noise Level(Sound Pressure)
Net
kW/kWEER
r.p.m
Fan
Speed
High
Low
High C.F.M(m3/h)Air Circulation
WFan Motor Output
kg
mm
Refrigerant
Type
Charge
Phase-Frequency
Max Chargeless Length
Max Length
Max Height
AJGA90EATA
25.40
-
86,600
-
380-415
3/50
16.20
-
63.00
9.40
-
2.70
-
730
360
5,770(9,800)
150x2
1,380
1,300
650
243(536)
57
R407C
3.1x2
9.53/19.05
50
30
30
0~52
-10~21
AJGA90TATA
25.40
28.60
86,600
97,500
380-415
3/50
16.20
17.00
63.00
9.40
10.00
2.70
2.86
730
360
5,770(9,800)
150x2
1,380
1,300
650
245(540)
57
R407C
3.1x2
9.53/19.05
50
30
30
0~52
-10~21
AJGA90EATB
25.40
-
86,600
-
380-415
3/50
16.20
-
63.00
9.40
-
2.70
-
730
360
5,770(9,800)
150x2
1,380
1,300
650
243(536)
57
R407C
6.00
12.70/28.58
50
30
30
0~52
-10~21
AJGA90TATB
25.40
28.60
86,600
97,500
380-415
3/50
16.20
17.00
63.00
9.40
10.00
2.70
2.86
730
360
5,770(9,800)
150x2
1,380
1,300
650
245(540)
57
R407C
6.00
12.70/28.58
50
30
30
0~52
-10~21
Individual OperationSimultaneous Operation
12.40-12.70
13.40-13.70
42,500-43,500
46,000-47,000
11.6
(5.5)
1,290
(2,200)
1,180
(2,000)
1,060
(1,800)
220-240
1/50
245
270
1,210
700
45(95)
9.53/19.05
Flare
ARXA45TATA
10.30-10.50
10.50-10.70
35,200-36,000
36,000-36,500
8.5
(4.0)
1,180
(2,000)
1,060
(1,800)
940
(1,600)
220-240
1/50
275
270
1,210
700
45(95)
9.53/19.05
Flare
ARXA36TATA
Individual Operation
Two refrigeration cycles
Various combinations of
indoor unit types and capacities
Centralized control by wired
remote controller with weekly timer
Cooling & heating at low
outdoor temperatures
Space saving
Easy installation
Features of System Operations
Individual Operating System is suitable for large spaces
such as hotels, commercial spaces, offices and
restaurants.
The system can cool and heat individually, because it
has two refrigeration cycles.
Indoor Unit Combinations
45,000+45,000(BTU/h)
1INDOOR UNIT1INDOOR UNIT
Outdoor Unit
Indoor Units Indoor Units
45,000+24,000/24,000(BTU/h)
2INDOOR UNITS1 INDOOR UNIT
Outdoor Unit
Indoor UnitsIndoor Units Indoor Units
24,000/24,000+24,000/24,000(BTU/h)
2INDOOR UNITS2 INDOOR UNITS
Outdoor Unit
Indoor Units Indoor UnitsIndoor Units Indoor Units
Outdoor units can be grouped together in a row.
Chargeless 30m
Heightdifference:30mmax.
Actual pipe length : 50m max.
Indoor Unit Lineup
CASSETTECASSETTE
(COMPACT) CAPACITY
(BTU)
45,000
30,000
(25,000)
24,000
18,000
DUCT
FLOOR/CEILING
UNIVERSAL CEILING(LARGE)
Indoor unit Indoor unit
Indoor unit Indoor unit
Outdoor unit
Wired remote
controller
UTB-YUB (option)
Refrigerant System
UTB-YUB
Wired remote
controller
UTB-YUB (option)
UTB-YUB
Gas pipe
Liquid pipe
Separation tube
Indoor unit
Outdoor unit
R407C