ARCHITECTURAL DESIGN
AMIR AZHAR ANSARI
B. ARCH SEM- IV
Dr. Bhim Rao Ambedkar Auditorium
Case Study- I
INTRODUCTION
ARCHITECTURAL DESIGN Dr. B.R.A AUDITORIUM
• DR. Bhim Rao Ambedkar auditorium is a
grand structure built in th...
ARCHITECTURAL DESIGN Dr. B.R.A. AUDITORIUM
Audi
2650
Audi
350
Food
cot
Buffer
zone
Foyer
entry
Parking
Stairs
Toilets
Stai...
ARCHITECTURAL DESIGN Dr. B.R.A AUDITORIUM
plan
Stage
10.5 r
Proscenium 3m W
Aisle 1.1m W
Back stage
Gangways 2m w
ARCHITECTURAL DESIGN Dr. B.R.A AUDITORIUM
section
ARCHITECTURAL DETAILS
ARCHITECTURAL DESIGN Dr. B.R.A AUDITORIUM
Auditorium of Cap. 2650
Auditorium of Cap. 350
• There are...
ARCHITECTURAL DESIGN Dr. B.R.A AUDITORIUM
AUDITORIUM
(CAPACITY :- 2650)
 STAGE
• Stage is in the shape of a semicircular ...
ARCHITECTURAL DESIGN Dr. B.R.A AUDITORIUM
AUDITORIUM
(CAPACITY :- 2650)
BACK STAGE
 BACK STAGE
• The back stage is built ...
ARCHITECTURAL DESIGN Dr. B.R.A AUDITORIUM
• The house of the auditorium is planned in
circular shape.
• It is of THRUST TY...
ARCHITECTURAL DESIGN Dr. B.R.A AUDITORIUM
Wall
Flooring
• Flooring is done with soft carpet for
acoustical as well as aest...
ARCHITECTURAL DESIGN Dr. B.R.A AUDITORIUM
AUDITORIUM
(CAPACITY :- 2650)
BALCONY
• Total number of ENTRY/EXIT- 4
• No. of ...
ARCHITECTURAL DESIGN Dr. B.R.A AUDITORIUM
Acoustics
Sound reinforcement system above the stage
Speakers mounted on the wal...
ARCHITECTURAL DESIGN
Focus lights
Dr. B.R.A AUDITORIUM
ARCHITECTURAL DESIGN Dr. B.R.A AUDITORIUM
Demerits
• Water Sprinklers are not provided for fire safety
system . only fire ...
ARCHITECTURAL DESIGN Dr. B.R.A AUDITORIUM
Standards
• Water sprinklers are the fastest and the
most effective preventive m...
ARCHITECTURAL DESIGN Dr. B.R.A AUDITORIUM
Dr. B.R. AMBEDKAR SABHAGHAR
• There were two foyers for the main auditorium
and ...
KGMU SCIENTIFIC CONVENTION CENTRE
CASE STUDY- II
Group Members:-
1. Harshit Srivastava
2. Mohd. Abdullah khan
3. Ibrahim A...
Panoramic view of House
Panoramic View of Stage
ARCHITECTURAL DESIGN SCIENTIFIC CONVENTION CENTRE
INTRODUCTION
• KGMU Scientific Convention centre is a grand
structure built on the Sardar Patel Hostel
grounds at Shahmina...
ARCHITECTURAL FEATURES
• The Convention Centre has a floor area of 200,000
sq feet.
• The dome measures 52.5 metre in diam...
• A foyer area below the dome and
connecting corridors.
• 8 lifts, including a capsule lift from which
historical building...
AUDITORIUM
(CAPACITY :- 1050)
STAGE
• Stage was in the shape of a sector of a
circle with the arch length of 26 m. and
Ch...
STAGE
BACKSTAGE FLOORINGSTAGE FLOORINGWINGS
BACKSTAGE COLUMN
ARCHITECTURAL DESIGN SCIENTIFIC CONVENTION CENTRE
PLAN OF STAGE AND SIDE STAGE
ARCHITECTURAL DESIGN SCIENTIFIC CONVENTION CENTRE
HOUSE
• Capacity- 1050 seats.
• Door (2200*2200)mm.
• Total number of Entry/Exit are 8.
• Entry/Exit No.1 & No.8 are for p...
OPEN
CHAIR
CLOSED
CHAIR
ARCHITECTURAL DESIGN SCIENTIFIC CONVENTION CENTRE
• Total number of gangways are 5.
• Central Gangway is 1500 millimeter
wide.
• Intermediate Gangways are 1350
millimeter w...
ACOUSTICS
• Audio-Visual control
panel to control audio,
Video.
• Acoustical tiles used in
the ceiling to avoid
acoustical...
Focus light in front of stage Curtain lifting machine
Diffused light above stage Back stage
ARCHITECTURAL DESIGN SCIENTIFI...
Banquet hall
 Capacity (400 pax)
• The plan of banquet hall was in circular
shape.
• The diameter of hall was 20 m.
• The...
v.i.p. parking
• The V.I.P. parking was constructed just
below the dome.
• The parking was built on trabeated
structure.
•...
THANK YOU
ARCHITECTURAL DESIGN SCIENTIFIC CONVENTION CENTRE
Próxima SlideShare
Cargando en…5
×

Dr. Bhim Rao Ambedkar Auditorium

10.126 visualizaciones

Publicado el

a presentation on dr. bhim rao ambedkar auditorium and sceintific convention center in the campus of king george medical college located in the Lucknow, U.P.
INDIA

Publicado en: Diseño
  • Inicia sesión para ver los comentarios

Dr. Bhim Rao Ambedkar Auditorium

  1. 1. ARCHITECTURAL DESIGN AMIR AZHAR ANSARI B. ARCH SEM- IV Dr. Bhim Rao Ambedkar Auditorium Case Study- I
  2. 2. INTRODUCTION ARCHITECTURAL DESIGN Dr. B.R.A AUDITORIUM • DR. Bhim Rao Ambedkar auditorium is a grand structure built in the campus of the Ram Manohar Lohiya Law university. • It is one of the India’s largest auditorium located near LDA’s Kanpur road, Lucknow. • It’s constructed was completed in 2011.
  3. 3. ARCHITECTURAL DESIGN Dr. B.R.A. AUDITORIUM Audi 2650 Audi 350 Food cot Buffer zone Foyer entry Parking Stairs Toilets Stairs Toilets V.I.P. rooms Bubble diagram
  4. 4. ARCHITECTURAL DESIGN Dr. B.R.A AUDITORIUM plan Stage 10.5 r Proscenium 3m W Aisle 1.1m W Back stage Gangways 2m w
  5. 5. ARCHITECTURAL DESIGN Dr. B.R.A AUDITORIUM section
  6. 6. ARCHITECTURAL DETAILS ARCHITECTURAL DESIGN Dr. B.R.A AUDITORIUM Auditorium of Cap. 2650 Auditorium of Cap. 350 • There are 2 Auditorium -Capacity 2650 -Capacity 350 • Separate entries for V.I.P. • 2 V.I.P. rooms. • A semi circular food cot • 2 Rehearsal rooms. • A foyer area before the entry in the auditorium and connecting corridors. • Audio visual cabin.
  7. 7. ARCHITECTURAL DESIGN Dr. B.R.A AUDITORIUM AUDITORIUM (CAPACITY :- 2650)  STAGE • Stage is in the shape of a semicircular with the radius of 10.5 m. • The level of elevation of stage is +900 mm. • The floor of the stage is finished with natural wooden battens. • The main purpose of wooden flooring is acoustical insulation as well as to make a smooth surface. • There is a projection screen at the back end of the stage measuring 12mx18m. • At both the ends of stage, the suspended screen are provided for the side rows audience. STAGE
  8. 8. ARCHITECTURAL DESIGN Dr. B.R.A AUDITORIUM AUDITORIUM (CAPACITY :- 2650) BACK STAGE  BACK STAGE • The back stage is built on the trabeated structure. • V.I.P. entries through the backstage. • It is also in the shape of semi circular of radius 27 m. • 2 entry/exit given along connected with the food cot and cyclorama. • A staircase is provided in the back stage which connect to the green room and rehearsal rooms. • It haa a cabin for Audio visual control system.
  9. 9. ARCHITECTURAL DESIGN Dr. B.R.A AUDITORIUM • The house of the auditorium is planned in circular shape. • It is of THRUST TYPE auditorium. • Total number of ENTRY/EXIT- 6 • The height of the ceiling from the last row is 3000mm. • Central Gangway is 2000 millimeter wide. • Intermediate Gangways are 1350 millimeter wide. • Total number of gangways are 7 in which 3 are intermediate gangways. • The proscenium width is 3000mm. AUDITORIUM (CAPACITY :- 2650)  LOWER HOUSE
  10. 10. ARCHITECTURAL DESIGN Dr. B.R.A AUDITORIUM Wall Flooring • Flooring is done with soft carpet for acoustical as well as aesthetic purpose. • Structural walls of the house are covered with veneered and soft carpet for decorative as well as acoustical purpose. • The dimension of door is 2000x2000mm. • Total no. of rows-16
  11. 11. ARCHITECTURAL DESIGN Dr. B.R.A AUDITORIUM AUDITORIUM (CAPACITY :- 2650) BALCONY • Total number of ENTRY/EXIT- 4 • No. of gangways -12. • The dimension of door is 2000x2000mm. • The level difference from the first to the last row is 9600mm. • The height of the riser is 600mm and total no. of steps is 48 of riser 200 mm each. • The railing is provided in the front of the first row of height 500mm. • Total number of rows are 18.
  12. 12. ARCHITECTURAL DESIGN Dr. B.R.A AUDITORIUM Acoustics Sound reinforcement system above the stage Speakers mounted on the walls Sound bars installed at the back of the last row Bass box
  13. 13. ARCHITECTURAL DESIGN Focus lights Dr. B.R.A AUDITORIUM
  14. 14. ARCHITECTURAL DESIGN Dr. B.R.A AUDITORIUM Demerits • Water Sprinklers are not provided for fire safety system . only fire alarm, smoke detector and fire extinguishers are provided. • Risers of the upper tier of the house were quite high and thus, are very uncomfortable. • The stage was not visible properly from the corner seats of the house. even the screens which were provided for the audience sitting on the corner seats were not properly visible due to the curvature of the stage.
  15. 15. ARCHITECTURAL DESIGN Dr. B.R.A AUDITORIUM Standards • Water sprinklers are the fastest and the most effective preventive method in case of indoor fire. Hence a public building like this must be provided with water sprinklers. • In no case, the riser height shall exceed 175mm. here, risers measured about 200mm in the last row of the upper tier. • The house shall be designed in such a way that the stage is visible from each and every seat with ease.
  16. 16. ARCHITECTURAL DESIGN Dr. B.R.A AUDITORIUM Dr. B.R. AMBEDKAR SABHAGHAR • There were two foyers for the main auditorium and a separate foyer for mini auditorium. • Lifts were not provided. • There was a buffer space at the entrance of the auditorium. • Seats measured 500*500mm. • Ramps were given in the intermediate Gangways • Stage measured 21.5m across its width and 10.5m along its depth. • A good quality of projection facility was provided along with 3 projectors and 3 screens. • Auditorium was equiped with high performance sound reinforcement system. • V.I.P. suites were not there . • There was a general parking only with capacity of 35 E.C.S. Kgmu convention centre • There was a common foyer for all the three auditoriums and amphitheatre . • Lifts were provided to reach different levels of the building. • No buffer space was provided at the entrance of the auditorium. • Seats of the house measured 400 by400mm, which were smaller then generally required. • Ramps were not provided in the gangways. • The proscenium width was 4000mm. • The stage measured 26m across its width and 12.5m along its depth. • There was no projection facility available, although projection screen was provided at the back of the stage. • General P.A. speakers were used for audio delivery. • V.I.P. suites were there for special guests. comparison
  17. 17. KGMU SCIENTIFIC CONVENTION CENTRE CASE STUDY- II Group Members:- 1. Harshit Srivastava 2. Mohd. Abdullah khan 3. Ibrahim Ahmad 4. Amir Azhar Ansari 5. Imran Khan 6. Ankit Dwivedi 7. Masir Ahmad Khan ARCHITECTURAL DESIGN SCIENTIFIC CONVENTION CENTRE
  18. 18. Panoramic view of House Panoramic View of Stage ARCHITECTURAL DESIGN SCIENTIFIC CONVENTION CENTRE
  19. 19. INTRODUCTION • KGMU Scientific Convention centre is a grand structure built on the Sardar Patel Hostel grounds at Shahmina Road, Lucknow. • It was built with MPs’ funds. The center was a project of Ex Prime Minister and Member of Parliament from Lucknow, Shri Atal Behari Vajpayee. • Its Construction started in 2001 and was completed in 2004. • It is used for national and international level scientific and cultural functions of the university. ARCHITECTURAL DESIGN SCIENTIFIC CONVENTION CENTRE
  20. 20. ARCHITECTURAL FEATURES • The Convention Centre has a floor area of 200,000 sq feet. • The dome measures 52.5 metre in diameter. • 3 Auditorium -Capacity 200 -Capacity 400 -Capacity 1050 • 2 banquet halls • 2 exhibition galleries • An open air theatre • A general library • Audiovisual library • Rehearsal rooms Auditorium of Cap. 400 Auditorium of Cap. 1050 ARCHITECTURAL DESIGN SCIENTIFIC CONVENTION CENTRE
  21. 21. • A foyer area below the dome and connecting corridors. • 8 lifts, including a capsule lift from which historical buildings of Lucknow can be seen. • 8 VIP suites with complete lodging facilities. • A complete kitchen and pantry & food hubs. ARCHITECTURAL DESIGN SCIENTIFIC CONVENTION CENTRE
  22. 22. AUDITORIUM (CAPACITY :- 1050) STAGE • Stage was in the shape of a sector of a circle with the arch length of 26 m. and Chord length of 23.6 m. and depth of stage is 12 m. upto the screen. • The level of elevation of stage is +900 mm. • The floor of the stage is finished with natural wooden battens, joined together with DOVE TAIL joints. • The main purpose of wooden flooring is acoustical insulation as well as to make a smooth surface. • There is a projection screen at the back end of the stage measuring 9 m. by 7 m.  BACK STAGE/SIDE STAGE • There are two side stages, one on each side of the stage. • Side stage and stage were bifurcated by Fins/Wings which are free to rotate on its axis. • Floor of side stage was covered with soft carpet ensuring comfort as well as acoustical insulation. • Side stage had a cabin for audio-visual control system. • The Column supporting the roof of stage was also covered with Acoustical carpet for acoustical insulation. ARCHITECTURAL DESIGN SCIENTIFIC CONVENTION CENTRE
  23. 23. STAGE BACKSTAGE FLOORINGSTAGE FLOORINGWINGS BACKSTAGE COLUMN ARCHITECTURAL DESIGN SCIENTIFIC CONVENTION CENTRE
  24. 24. PLAN OF STAGE AND SIDE STAGE ARCHITECTURAL DESIGN SCIENTIFIC CONVENTION CENTRE
  25. 25. HOUSE • Capacity- 1050 seats. • Door (2200*2200)mm. • Total number of Entry/Exit are 8. • Entry/Exit No.1 & No.8 are for physically disabled citizens. • Height of the ceiling is around 10 meter to 12 meter. • Minimum ceiling height is 5.6 meter (at the backside). • Aisle is 1100 millimeter wide. • Aisle is after 8 rows from the last row. • Level difference between first row and last row 6300 millimeter. • Distance between stage and first row of seating (Proscenium) is 4000 millimeter. • Chair dimension - Empty Chair = (400*600)mm - Occupied Chair = (400*700)mm ARCHITECTURAL DESIGN SCIENTIFIC CONVENTION CENTRE
  26. 26. OPEN CHAIR CLOSED CHAIR ARCHITECTURAL DESIGN SCIENTIFIC CONVENTION CENTRE
  27. 27. • Total number of gangways are 5. • Central Gangway is 1500 millimeter wide. • Intermediate Gangways are 1350 millimeter wide. • Outer Gangways are 1650 millimeter wide. • Flooring is done with soft carpet for acoustical as well as aesthetic purpose. • Structural walls of the house are covered with particle boards lined with decorative laminates for decorative as well as acoustical purpose. • The house of the auditorium is planned in oval shape. WALL CLADDING ARCHITECTURAL DESIGN SCIENTIFIC CONVENTION CENTRE
  28. 28. ACOUSTICS • Audio-Visual control panel to control audio, Video. • Acoustical tiles used in the ceiling to avoid acoustical defects. • Tiles were made of perforated MDF of size 600*600mm. • Ceiling is kept high so that sound may travel easily throughout the house. ARCHITECTURAL DESIGN SCIENTIFIC CONVENTION CENTRE
  29. 29. Focus light in front of stage Curtain lifting machine Diffused light above stage Back stage ARCHITECTURAL DESIGN SCIENTIFIC CONVENTION CENTRE
  30. 30. Banquet hall  Capacity (400 pax) • The plan of banquet hall was in circular shape. • The diameter of hall was 20 m. • The roof of the hall was SLANT due to auditorium present above the hall on the first floor. • The floor of the hall is finished with the vitrified tiles of dimension 600x600 mm. • Total no. of entry/exit 4. • The false ceiling was provided.  Capacity (200 pax) • The plan of banquet hall was in circular shape. • The diameter of hall was 16m. • The roof of the hall was plain. • The floor of the hall is finished with the vitrified tiles of dimension 600x600 mm. • Total no. of entry/exit 3. • The false ceiling was provided. • There was no intermediate columns. ARCHITECTURAL DESIGN SCIENTIFIC CONVENTION CENTRE
  31. 31. v.i.p. parking • The V.I.P. parking was constructed just below the dome. • The parking was built on trabeated structure. • The entry/exit into the parking is through a gallery . • The dimension of gallery is 5.5x71 m. • Total no. of columns :19 • The size the columns are 500x500mm and 650x650mm. • The O.T.S. was provided on both corner of the parking. • . ARCHITECTURAL DESIGN SCIENTIFIC CONVENTION CENTRE
  32. 32. THANK YOU ARCHITECTURAL DESIGN SCIENTIFIC CONVENTION CENTRE

×