2. Ethane
usually recovered from natural gas fields mainly USA
Propane/butane
recovered from gas fields middle east, Texas etc. Kuwait has a
large butane recovery system. Also can come from LNG plants
Refinery naphtha / condensate
C5 to C7 paraffin based low octane naphtha from refineries also
from natural gas / oil well head production
Light and heavy gas oils
refinery based (200 to 350°C) AGO and (350 to 550 °C) VGO
The more paraffinic the feedstock the higher the ethylene yields
and the greater the value of the co-products
3. Sulfur
+ Cracks in furnaces to give H2S and COS. Mercaptans in C3/C4 cuts,
RSH and thiophenes in gasoline, benzothiophenes in fuel oil
Arsenic
+ Organic or arsine
+ Makes arsine in the furnaces and some remains as organic
Mercury
+ Metallic / organic
+ Decomposes to metallic some remains as organic
Ballast water
+ Sea water from shipping feed stock
Metals
+ Nickel, sodium, vanadium, iron from heavy feedstocks
FCCU off gas (gas compressor suction, developing trend)
+ NOx, H2S, amines, SbH3, As , COS, O2, CO2 plus others
4. Feedstock West
Europe
USA Japan World
Ethane 8 57.5 30.5
LPG 11 19 7.5 11
Naphtha 69 9.5 92.5 49
Gas Oil 12 14 8.5
Others 1*
Figures as wt%
* Ethanol Brazil and India and Coal based gases Poland
6. Paraffin C7H16
Primary Cracking
C3H8 + 1-C4H8
Dehydrogenation
C7H14
Cracked
Products
Butadiene
C4H6
Secondary
Cracking
Propylene
C3H6
Propyne
C3H4
CH4+ C2H4 2C2H4
Acetylene
C2H2
Cyclo additions and
Dehydrogenation
give aromatics pyrolysis
tar and coke
Selectively Hydrogenated Free radical chain reaction
initiated in furnace tubes
7. Halliburton Kellogg Brown &
Root (milli second)
Lummus
Stone & Webster
CF Braun
Linde
BASF
ExxonMobil
KTI
Technip
Each furnace designer has
their own characteristics
Temperature ranges 700°C
to 900 °C
Residence times 0.2 ( new
units) to 15 secs (older
design)
Steam injection into the
furnaces minimise coke
gives CO formation (C +
H2O=CO+ H2) 0.2 to 0.5 wt%
feed
Tube outlet pressure 0.5 to
2 bar
9. FRONT END DE_ETHANISER
C2H2
Reactors
Driers
T
1
0
2
Cold
Box
C3’s, C4’s and pygas
C2H4/C2H6
CH4, CO H2
Demethaniser
De-ethaniser
FRONT END DE_DEPROPANISER
Driers
T
1
0
2
C4’s and pygas
Depropaniser
C2H2
Reactors
Cold
Box
C2H4/C2H6
CH4, CO H2
De-ethaniser
Demethaniser C3H6/C3H8
Gas Compression
System
Gas Compression
System
11. Front end acetylene -( Pd on alumina)
De-ethanizer overhead
Depropanizer overhead
Wet gas
Tail end acetylene -(Pd on alumina)
MAPD and butadiene -(Pd on alumina)
Methanation catalysts ( Ni on alumina)
High activity hydrogenation for C4 or C5 recycle (Pd or HTC)
Pyrolysis gasoline -( Ni or Pd on alumina)
Ethylene / propylene purification systems
Purification
Hg from feed or upstream of Pd catalysts
Arsenic from feed or C3 cut or from py gas feed
COS hydrolysis in the wet gas system
H2S ZnO
absorption
12. SG15/4 or 15/15 equivalent to kg/m3
T in SOR inlet temperature start of run
T in EOR inlet temperature end of run
Partial pressure NOT same as reactor
pressure
Hydrogen terminology
◦ Chemical usage nm3/m3 feed
◦ Solution loss nm3/m3
◦ MUG-make up gas nm3/hr
◦ Purge gas excess hydrogen to remove
inert gases
◦ Recycle gas rate
LHSV volumes feed/volume catalyst
Reactor fill cost gives actual cost for
comparisons ( Catalyst SG)
Life Hours m3 feed/kg catalyst preferred
or feed component converted
GHSV care is it actual or normal basis?
EIT equivalent isothermal temperature
(WABT)
Feed distillations (Check out what they
are)
◦ ASTM
◦ TBP
◦ Sim Dist GLC
◦ Boiling range
Average boiling point
Others (Check out what they mean)
◦ MAV
◦ UV ( not only at one wavelength)
◦ Iodine number
◦ Bromine number
14. Ethylene Selectivity :
% SC2H4 = 100 - % SC2H6 - % SC4+ - % SC6+
% SC2H6 is the ethane selectivity :
% SC2H6 = {[(C2H6)out –(C2H6)in]/[(C2H2)in-(C2H2)out ]}x 100
% SC4+ is the total C4 selectivity formed (i.e. Cis- and
trans-but-2-enes, but-1-ene and buta-1,3-diene), :
% SC4+ = {[2x(C4'sformed)]/[(C2H2)in-(C2H2)out]} x 100
(2 moles C2H2 1 mole C4’s)
% SC6+ is the total C6 selectivity formed,:
% SC6+ = {[3x(C6'sformed)]/ [(C2H2)in-(C2H2)out]} x 100
(3 moles C2H2 1 mole C6’s)
Important to ask customer his definition, many variations
15. Catalysts are sock loaded
Can be regenerated some in situ
steam/air some offsite
No activation step used
No of reactors and configuration
depends on plant
New units, 25°C −T each reactor
Front end units always work in
high CO and excess hydrogen
Tail end 2 to 5% excess hydrogen
5 ppm added CO. Susceptible to
green oil formation.
Usually one spare in either front
or tail end systems. Will vary
Acetylene spec is >10ppm in
C2H4. This is <1ppm front end
design
Cooling
Medium
C4
Methanol
Cracked Gas Cracked Gas
FRONT END
Isothermal Adiabatic
TAIL END
16. Components Average High
C3’s 0.3 0.3
N-butane 5.2 2.8
Iso-butane 1.3 0.6
1-butene 16 13.7
Cis 2-butene 5.3 4.8
Trans 2 –butene 6.6 5.8
Iso butene 27.4 22.2
Butadiene 37 47.5
Acetylenics 0.4 1.8
C5’s 0.5 0.5
The LPG stream often further processed. Butadiene can be
extracted, selective hydrogenation of raffinates, mono olefins
into co polymers, solvents etc, MTBE . Full hydrogenation of
C4’s for LPG transportation fuel or recycle to the furnaces.
19. Crude
Gasoline
Hydrogenated Hydro-treated
IP (ASTM) °C 40 43 43
50% °C 98 100 100
EP °C 195 200 200
SG 0.83 .832 .835
Diene I2gms/100gms 27 1 >0.1
Bromine No 75 60 >0.5
Total Sulphur ppm 400 400 >1
Styrene wt% 5.0 0.1 >0.001
RONC 97 97
MONC 86 86
Catalyst HTC /Pd NiMo/ CoMo
Temperature In/Out °C 70/120 250/320
Pressure Bar 27-50 27-50
LHSV 1 to 3 1 to 3
20. Some Definitions -2
Purge gasInlet
Temperature
Partial Pressure
Hydrogen
consumption
Make up gas
Recycle gas
Solution loss
in product
Outlet
Temperature
EIT =Tin+ (Tout-
Tin) x (2/3)
Fresh Feed
21. Distillation curves
0
50
100
150
200
250
0 20 40 60 80 100
Volume % distilled
TemperatureDegC
TBP/Sim Dist
ASTM D86
Important to define ASTM { D86
(<350°C EP) or D1160 (> 350°C IP)},
Sim Distillation (HPLC/GLC)
Distillation Data and SG is
minimum required to calculate
other properties
◦ Average boiling points (TABP,
MeABP, VABP)
◦ K for flash data
◦ MW or hydrogen consumptions
◦ Critical properties (Tc Pc) and heats
of reaction
◦ n-d-m data for aromatic contents
Gives properties of the feeds and
products for calculations.
22. Pilot plant isothermal
Plant adiabatic
Use Tin conversion too
low
Use T out conversion too
high
EIT = Tin +(Tout-Tin) x Ι
Choose some point to try
to match conversion
◦ will depend on reaction
◦ slow Ι = 0.4
◦ fast Ι = 0.75
◦ average Ι = 0.66
Look out for equilibrium
operations
Flow FL
Flow RL
Flow RG
Flow MG
Conversion Data
45
55
65
75
85
95
75 125 175
Temperature Deg C
Conversionwt%