SlideShare a Scribd company logo
1 of 59
Download to read offline
Development Length
and
Lap Splices
Bond, Development Lengths, and
Splices
1. Bond stress
- A basic assumption made for RC design: there must be
absolutely no slippage of the bars in relation to the
surrounding concrete. That means the steel and the
concrete should stick together or bond so they will act as a
unit. If not, the bars are not anchored at their ends.
Development of Bond Stresses: flexural bond
Flexure bond
1 2 1 2 1 2
; and
T T M M C C
  
But
At any section, dT = dM/jd
Where u is the average bond stress and ΣO is the sum of
perimeters of bars in the tension side.
The rate of change of the moment with respect to x is the shear, or
dM/dx = V
For practical calculations, j = 0.87
0.87
V
u
d O


In the strength design method, the nominal bond strength is
reduced by capacity reduction factor ϕ = 0.85 , thus
 
0.87
u
u
V
U
d O



Tests for bond efficiency
Pull out test
Tests for bond efficiency
Type of bond failures
2. Development length for tension reinforcing
The minimum length of embedment of bars that is necessary
to permit them to be stressed to their yield point plus some
extra distance to ensure member toughness.
2. Development length for tension reinforcing
 
2
For equilibrium condition:
and
For a combination of bars,
The length is the minimum permissible anchorage length
and is called the development length.
4
s y
s y u d d
u
s y
d
u
d
b y
d
u b
A f
A f U Ol l
U O
A f
l
U O
l
d f
l
U d


 

 

4
where = diameter of reinforcing bars
b y
u
b
d f
U
d
► The development length in tension may not be less than the
value computed from Eq. below or 300mm.
Where
• ld = development length, mm.
• db = nominal diameter of bar or wire, mm.
• fy = specified yield strength of nonprestressed bar or wire, MPa
• fc′ = specified compressive strength of concrete, MPa
9
10
y
d t e s
b c b tr
b
f
l
d f c K
d
  


 
 
 
 
• ψt = reinforcement location factor
= 1.3 for horizontal reinforcement placed such that
more than 300mm of fresh concrete is cast below
the development length or splice
= 1.0 for other reinforcement
• ψe = coating factor
= 1.5 for epoxy-coated bars or wires with cover less
than 3db or clear spacing less than 6db
= 1.2 for all other epoxy-coated bars or wires
= 1.0 for uncoated reinforcement
The product of ψt and ψe need not be taken greater than 1.7
• ψs = reinforcement size factor
= 0.8 for DB20mm and smaller bars and deformed wires
= 1.0 for DB22mm and larger bars
• λ = lightweight aggregate concrete factor
= 0.75 when lightweight concrete is used or
= when fct is specified, but not less than 1.0
= 1.0 for normal weight concrete
• cb = spacing or cover dimension, mm.
= the smaller of
(a) distance from center of bar or wire being developed to
the nearest concrete surface,
(b) one-half the center-to-center spacing of bars or
wires being developed
1.8
c ct
f f

Concrete stresses in a circular concrete prism containing a
reinforcing bar that is subjected to bond stresses, shown
in section.
• Ktr = transverse reinforcement index
where
• Atr = total cross-sectional area of all transverse reinforcement
which is within the spacing s and which crosses the
potential plane of splitting through the reinforcement
being developed, mm2
• s = maximum spacing of transverse reinforcement within ld,
center-to-center, mm.
• n = number of bars or wires being developed along the
plane of splitting
10
tr tr
tr
A f
K
sn

• Note that the term not greater than 2.5 (ACI code
section 12.2.3) to safeguard against pullout type failures.
To simplify the calculation the code also permit to use Ktr = 0
b tr
b
c K
d
 

 
 
Definition of Atr
If the flexural reinforcement provided exceeds the amount
required to resist the factored moment, the bar stress that must
be developed is less than fy. In such a case, ACI Code Section
12.2.5 allows to be multiplied by (As required/ As provided).
This multiplier is not applied in the design of members
resisting seismic loads.
The value of can not be greater than 8.3 MPa
c
f 
DB20 mm and
smaller bars and
deformed wires
DB22 mm and
larger bars
(Case 1) Clear spacing of bars
or wires being developed or
spliced not less than db, clear
cover not less than db, and
stirrups or ties throughout ld not
less than the code minimum
or
(Case 2) Clear spacing of bars
or wires being developed or
spliced not less than 2db and
clear cover not less than db
Other cases
2.1
y t e
d
b c
f
l
d f
 


 1.7
y t e
d
b c
f
l
d f
 



1.4
y t e
d
b c
f
l
d f
 


 1.1
y t e
d
b c
f
l
d f
 



2. Compression-Development length
Development length of bars in compression should be greater
than below Eq.
and
and
0.24 y
dc
b c
f
l
d f



0.043
dc
y
b
l
f
d

200
dc
l mm

It can be reduced by factor Rs = As, required/As, provided
3. Development of bundle bars
• Development length of individual bars within a bundle, in
tension or compression, shall be that for the individual bar,
increased 20 percent for three-bar bundle, and 33 percent for
four-bar bundle.
• For determining the appropriate spacing and cover values, and
the ψe factor, a unit of bundled bars shall be treated as a single
bar of a diameter derived from the equivalent total area and
having a centroid that coincides with that of the bundled bars.
Design Aids
ASTM Standard Metric Reinforcing Bars
4. Critical Section In Flexural Members
The critical sections for development of reinforcement in flexural
members are
• At points of maximum stress
• At points where tension bars within the span are terminated or bent
• At the face of the support
• At points of inflection at which moment changes signs
5. Standard Hooks (ACI Code section 12.5 and 7.1)
Development length of hooked bar ldh :
ldh = development length for hooked bar, mm.
Ψe = coating factor
= 1.2 for all other epoxy-coated bars or wires
= 1.0 for uncoated reinforcement
0.24
(Modification Factor)
e y
dh
b c
f
l
d f


 

• (a) For No. 36 bar and smaller hooks with side cover (normal
to plane of hook) not less than 65 mm, and for 90-degree hook
with cover on bar extension beyond hook not less than
50mm....................... 0.7
• (b) For 90-degree hooks of No. 36 and smaller bars that are
either enclosed within ties or stirrups perpendicular to the bar
being developed, spaced not greater than 3db along ldh; or
enclosed within ties or stirrups parallel to the bar being
developed, spaced not greater than 3db along the length of the
tail extension of the hook plus bend .................... 0.8
• (c) For 180-degree hooks of No. 36 and smaller bars that are
enclosed within ties or stirrups perpendicular to the bar being
developed, spaced not greater than 3db along
ldh ...................................................... 0.8
• (d) Where anchorage or development for fy is not specifically
required, reinforcement in excess of that required by
analysis ....... (As required)/(As provided)
Lap Splices in Tension, lst
 Shall be as required for Class A or B splice, but not
less than 300 mm, where:
• Class A splice................................................... 1.0ld
• Class B splice................................................... 1.3ld
where ld is the development length
Lap Splices in Compression, lsc
 Shall not be less than 300 mm
 
For bars with 420 0.071
For bars with 420 0.13 24
For 21 , Required lap is increased by 1/3
y sc y b
y sc y b
c
f MPa l f d
f MPa l f d
f MPa
 
  
 
Moment-Resistance Diagram(Bar Cutoff Points)
 The factored moment capacity of an under-reinforced
concrete beam at any section is:
2
u s y
a
M A f d

 
 
 
 
The factored moment resistance of one bar, is
2
0.85
area of one bar
ub
ub sb y
s y
c
sb
M
a
M A f d
A f
where a
f b
A

 
 
 
 



• Note (a): Portion
of total negative
reinforcement (As
-)
must be continuous
(or spliced with a
Class B splice or
a mechanical or
welded splice
satisfying 12.14.3)
along full length of
perimeter beams
(7.13.2.2).
(a) Negative Moment
Reinforcement
• Note (b): Portion of total
positive reinforcement
(As
+) must be continuous
(or spliced with a Class
B splice or
a mechanical or welded
splice satisfying 12.14.3)
along full length of
perimeter beams and of
beams without
closed stirrups (7.13.2.2).
See also 7.13.2.4.
(b) Positive Moment
Reinforcement
6. Development length-update14122012.pdf
6. Development length-update14122012.pdf
6. Development length-update14122012.pdf

More Related Content

Similar to 6. Development length-update14122012.pdf

Connection_Design.ppt
Connection_Design.pptConnection_Design.ppt
Connection_Design.pptkasarla sagar
 
Connection_Design.ppt
Connection_Design.pptConnection_Design.ppt
Connection_Design.pptDrAlfia
 
Connection_Design.ppt
Connection_Design.pptConnection_Design.ppt
Connection_Design.pptssuser474b33
 
Sd i-module2- rajesh sir
Sd i-module2- rajesh sirSd i-module2- rajesh sir
Sd i-module2- rajesh sirSHAMJITH KM
 
Tension members
Tension membersTension members
Tension memberssky hawk
 
Calulation of deflection and crack width according to is 456 2000
Calulation of deflection and crack width according to is 456 2000Calulation of deflection and crack width according to is 456 2000
Calulation of deflection and crack width according to is 456 2000Vikas Mehta
 
Engineering science lesson 6 2
Engineering science lesson 6 2Engineering science lesson 6 2
Engineering science lesson 6 2Shahid Aaqil
 
Connections
ConnectionsConnections
Connectionssky hawk
 
ch-02_cotter-joint-knuckle-joint-design.pdf
ch-02_cotter-joint-knuckle-joint-design.pdfch-02_cotter-joint-knuckle-joint-design.pdf
ch-02_cotter-joint-knuckle-joint-design.pdfPraveen Kumar
 
Design analysis of Cotter joint used in piston rod and crosshead a.pptx
Design analysis of Cotter joint used in piston rod and crosshead a.pptxDesign analysis of Cotter joint used in piston rod and crosshead a.pptx
Design analysis of Cotter joint used in piston rod and crosshead a.pptx138HemangiAhire
 
Lecture Riveted Joints by molvie imran.pptx
Lecture  Riveted Joints by molvie imran.pptxLecture  Riveted Joints by molvie imran.pptx
Lecture Riveted Joints by molvie imran.pptxBDULQAYYUM
 
Bond strength and developement length
Bond strength and developement lengthBond strength and developement length
Bond strength and developement lengthSushilAdhikari25
 
Concrete flexural design
Concrete flexural designConcrete flexural design
Concrete flexural designWaqas Javaid
 
Connection design
Connection designConnection design
Connection designEduardo
 
Design of Structures Chapter2.pdf
Design of Structures Chapter2.pdfDesign of Structures Chapter2.pdf
Design of Structures Chapter2.pdfUmarSaba1
 
Iii design-of-steel-structures-unit-2
Iii design-of-steel-structures-unit-2Iii design-of-steel-structures-unit-2
Iii design-of-steel-structures-unit-2saibabu48
 

Similar to 6. Development length-update14122012.pdf (20)

Connection_Design.ppt
Connection_Design.pptConnection_Design.ppt
Connection_Design.ppt
 
Connection_Design.ppt
Connection_Design.pptConnection_Design.ppt
Connection_Design.ppt
 
Connection_Design.ppt
Connection_Design.pptConnection_Design.ppt
Connection_Design.ppt
 
Sd i-module2- rajesh sir
Sd i-module2- rajesh sirSd i-module2- rajesh sir
Sd i-module2- rajesh sir
 
Tension members
Tension membersTension members
Tension members
 
Calulation of deflection and crack width according to is 456 2000
Calulation of deflection and crack width according to is 456 2000Calulation of deflection and crack width according to is 456 2000
Calulation of deflection and crack width according to is 456 2000
 
Engineering science lesson 6 2
Engineering science lesson 6 2Engineering science lesson 6 2
Engineering science lesson 6 2
 
0 ne way slab
0 ne way slab0 ne way slab
0 ne way slab
 
Connections
ConnectionsConnections
Connections
 
ch-02_cotter-joint-knuckle-joint-design.pdf
ch-02_cotter-joint-knuckle-joint-design.pdfch-02_cotter-joint-knuckle-joint-design.pdf
ch-02_cotter-joint-knuckle-joint-design.pdf
 
Design analysis of Cotter joint used in piston rod and crosshead a.pptx
Design analysis of Cotter joint used in piston rod and crosshead a.pptxDesign analysis of Cotter joint used in piston rod and crosshead a.pptx
Design analysis of Cotter joint used in piston rod and crosshead a.pptx
 
Development length
Development length Development length
Development length
 
Lecture Riveted Joints by molvie imran.pptx
Lecture  Riveted Joints by molvie imran.pptxLecture  Riveted Joints by molvie imran.pptx
Lecture Riveted Joints by molvie imran.pptx
 
Bond strength and developement length
Bond strength and developement lengthBond strength and developement length
Bond strength and developement length
 
Concrete flexural design
Concrete flexural designConcrete flexural design
Concrete flexural design
 
Fmd riveted joints
Fmd riveted jointsFmd riveted joints
Fmd riveted joints
 
9793339.ppt
9793339.ppt9793339.ppt
9793339.ppt
 
Connection design
Connection designConnection design
Connection design
 
Design of Structures Chapter2.pdf
Design of Structures Chapter2.pdfDesign of Structures Chapter2.pdf
Design of Structures Chapter2.pdf
 
Iii design-of-steel-structures-unit-2
Iii design-of-steel-structures-unit-2Iii design-of-steel-structures-unit-2
Iii design-of-steel-structures-unit-2
 

More from RiSovannaphumi

1. Properties of reinforced concrete.pdf
1. Properties of reinforced concrete.pdf1. Properties of reinforced concrete.pdf
1. Properties of reinforced concrete.pdfRiSovannaphumi
 
InspectionSamplingProceduresFineCoarseAggregates.pdf
InspectionSamplingProceduresFineCoarseAggregates.pdfInspectionSamplingProceduresFineCoarseAggregates.pdf
InspectionSamplingProceduresFineCoarseAggregates.pdfRiSovannaphumi
 
APHEDA_Not_Here_Not_Anywhere_Campaign_Update_2022_Steve_Mullins.pdf
APHEDA_Not_Here_Not_Anywhere_Campaign_Update_2022_Steve_Mullins.pdfAPHEDA_Not_Here_Not_Anywhere_Campaign_Update_2022_Steve_Mullins.pdf
APHEDA_Not_Here_Not_Anywhere_Campaign_Update_2022_Steve_Mullins.pdfRiSovannaphumi
 
Book of Auto CAD by tin vuthnak A5.pdf
Book of Auto CAD by tin vuthnak A5.pdfBook of Auto CAD by tin vuthnak A5.pdf
Book of Auto CAD by tin vuthnak A5.pdfRiSovannaphumi
 
BS1019 Leaflet 2022-May.pdf
BS1019 Leaflet 2022-May.pdfBS1019 Leaflet 2022-May.pdf
BS1019 Leaflet 2022-May.pdfRiSovannaphumi
 

More from RiSovannaphumi (7)

10. One-way slab.pdf
10. One-way slab.pdf10. One-way slab.pdf
10. One-way slab.pdf
 
1. Properties of reinforced concrete.pdf
1. Properties of reinforced concrete.pdf1. Properties of reinforced concrete.pdf
1. Properties of reinforced concrete.pdf
 
InspectionSamplingProceduresFineCoarseAggregates.pdf
InspectionSamplingProceduresFineCoarseAggregates.pdfInspectionSamplingProceduresFineCoarseAggregates.pdf
InspectionSamplingProceduresFineCoarseAggregates.pdf
 
APHEDA_Not_Here_Not_Anywhere_Campaign_Update_2022_Steve_Mullins.pdf
APHEDA_Not_Here_Not_Anywhere_Campaign_Update_2022_Steve_Mullins.pdfAPHEDA_Not_Here_Not_Anywhere_Campaign_Update_2022_Steve_Mullins.pdf
APHEDA_Not_Here_Not_Anywhere_Campaign_Update_2022_Steve_Mullins.pdf
 
Book of Auto CAD by tin vuthnak A5.pdf
Book of Auto CAD by tin vuthnak A5.pdfBook of Auto CAD by tin vuthnak A5.pdf
Book of Auto CAD by tin vuthnak A5.pdf
 
BS1019 Leaflet 2022-May.pdf
BS1019 Leaflet 2022-May.pdfBS1019 Leaflet 2022-May.pdf
BS1019 Leaflet 2022-May.pdf
 
AQR831084.pdf
AQR831084.pdfAQR831084.pdf
AQR831084.pdf
 

Recently uploaded

(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
Introduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxIntroduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxupamatechverse
 
result management system report for college project
result management system report for college projectresult management system report for college project
result management system report for college projectTonystark477637
 
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Call Girls in Nagpur High Profile
 
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLSMANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLSSIVASHANKAR N
 
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
UNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its PerformanceUNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its Performancesivaprakash250
 
Extrusion Processes and Their Limitations
Extrusion Processes and Their LimitationsExtrusion Processes and Their Limitations
Extrusion Processes and Their Limitations120cr0395
 
Introduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxIntroduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxupamatechverse
 
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCollege Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCall Girls in Nagpur High Profile
 
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete RecordCCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete RecordAsst.prof M.Gokilavani
 
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Dr.Costas Sachpazis
 
UNIT-III FMM. DIMENSIONAL ANALYSIS
UNIT-III FMM.        DIMENSIONAL ANALYSISUNIT-III FMM.        DIMENSIONAL ANALYSIS
UNIT-III FMM. DIMENSIONAL ANALYSISrknatarajan
 
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Bookingdharasingh5698
 
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxAsutosh Ranjan
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Dr.Costas Sachpazis
 
KubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghlyKubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghlysanyuktamishra911
 

Recently uploaded (20)

(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
Introduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxIntroduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptx
 
result management system report for college project
result management system report for college projectresult management system report for college project
result management system report for college project
 
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
 
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLSMANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
 
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
 
UNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its PerformanceUNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its Performance
 
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
 
Extrusion Processes and Their Limitations
Extrusion Processes and Their LimitationsExtrusion Processes and Their Limitations
Extrusion Processes and Their Limitations
 
Introduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxIntroduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptx
 
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
 
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCollege Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
 
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete RecordCCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
 
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
 
UNIT-III FMM. DIMENSIONAL ANALYSIS
UNIT-III FMM.        DIMENSIONAL ANALYSISUNIT-III FMM.        DIMENSIONAL ANALYSIS
UNIT-III FMM. DIMENSIONAL ANALYSIS
 
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
 
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptx
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
 
KubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghlyKubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghly
 

6. Development length-update14122012.pdf

  • 2. Bond, Development Lengths, and Splices 1. Bond stress - A basic assumption made for RC design: there must be absolutely no slippage of the bars in relation to the surrounding concrete. That means the steel and the concrete should stick together or bond so they will act as a unit. If not, the bars are not anchored at their ends.
  • 3. Development of Bond Stresses: flexural bond Flexure bond 1 2 1 2 1 2 ; and T T M M C C   
  • 4. But At any section, dT = dM/jd Where u is the average bond stress and ΣO is the sum of perimeters of bars in the tension side. The rate of change of the moment with respect to x is the shear, or dM/dx = V
  • 5. For practical calculations, j = 0.87 0.87 V u d O   In the strength design method, the nominal bond strength is reduced by capacity reduction factor ϕ = 0.85 , thus   0.87 u u V U d O   
  • 6. Tests for bond efficiency Pull out test
  • 7. Tests for bond efficiency
  • 8.
  • 9.
  • 10. Type of bond failures
  • 11. 2. Development length for tension reinforcing The minimum length of embedment of bars that is necessary to permit them to be stressed to their yield point plus some extra distance to ensure member toughness.
  • 12. 2. Development length for tension reinforcing   2 For equilibrium condition: and For a combination of bars, The length is the minimum permissible anchorage length and is called the development length. 4 s y s y u d d u s y d u d b y d u b A f A f U Ol l U O A f l U O l d f l U d         4 where = diameter of reinforcing bars b y u b d f U d
  • 13. ► The development length in tension may not be less than the value computed from Eq. below or 300mm. Where • ld = development length, mm. • db = nominal diameter of bar or wire, mm. • fy = specified yield strength of nonprestressed bar or wire, MPa • fc′ = specified compressive strength of concrete, MPa 9 10 y d t e s b c b tr b f l d f c K d             
  • 14. • ψt = reinforcement location factor = 1.3 for horizontal reinforcement placed such that more than 300mm of fresh concrete is cast below the development length or splice = 1.0 for other reinforcement • ψe = coating factor = 1.5 for epoxy-coated bars or wires with cover less than 3db or clear spacing less than 6db = 1.2 for all other epoxy-coated bars or wires = 1.0 for uncoated reinforcement The product of ψt and ψe need not be taken greater than 1.7
  • 15. • ψs = reinforcement size factor = 0.8 for DB20mm and smaller bars and deformed wires = 1.0 for DB22mm and larger bars • λ = lightweight aggregate concrete factor = 0.75 when lightweight concrete is used or = when fct is specified, but not less than 1.0 = 1.0 for normal weight concrete • cb = spacing or cover dimension, mm. = the smaller of (a) distance from center of bar or wire being developed to the nearest concrete surface, (b) one-half the center-to-center spacing of bars or wires being developed 1.8 c ct f f 
  • 16. Concrete stresses in a circular concrete prism containing a reinforcing bar that is subjected to bond stresses, shown in section.
  • 17. • Ktr = transverse reinforcement index where • Atr = total cross-sectional area of all transverse reinforcement which is within the spacing s and which crosses the potential plane of splitting through the reinforcement being developed, mm2 • s = maximum spacing of transverse reinforcement within ld, center-to-center, mm. • n = number of bars or wires being developed along the plane of splitting 10 tr tr tr A f K sn 
  • 18. • Note that the term not greater than 2.5 (ACI code section 12.2.3) to safeguard against pullout type failures. To simplify the calculation the code also permit to use Ktr = 0 b tr b c K d        Definition of Atr
  • 19. If the flexural reinforcement provided exceeds the amount required to resist the factored moment, the bar stress that must be developed is less than fy. In such a case, ACI Code Section 12.2.5 allows to be multiplied by (As required/ As provided). This multiplier is not applied in the design of members resisting seismic loads. The value of can not be greater than 8.3 MPa c f 
  • 20. DB20 mm and smaller bars and deformed wires DB22 mm and larger bars (Case 1) Clear spacing of bars or wires being developed or spliced not less than db, clear cover not less than db, and stirrups or ties throughout ld not less than the code minimum or (Case 2) Clear spacing of bars or wires being developed or spliced not less than 2db and clear cover not less than db Other cases 2.1 y t e d b c f l d f      1.7 y t e d b c f l d f      1.4 y t e d b c f l d f      1.1 y t e d b c f l d f     
  • 21.
  • 22.
  • 23. 2. Compression-Development length Development length of bars in compression should be greater than below Eq. and and 0.24 y dc b c f l d f    0.043 dc y b l f d  200 dc l mm  It can be reduced by factor Rs = As, required/As, provided
  • 24. 3. Development of bundle bars • Development length of individual bars within a bundle, in tension or compression, shall be that for the individual bar, increased 20 percent for three-bar bundle, and 33 percent for four-bar bundle. • For determining the appropriate spacing and cover values, and the ψe factor, a unit of bundled bars shall be treated as a single bar of a diameter derived from the equivalent total area and having a centroid that coincides with that of the bundled bars.
  • 26. ASTM Standard Metric Reinforcing Bars
  • 27. 4. Critical Section In Flexural Members The critical sections for development of reinforcement in flexural members are • At points of maximum stress • At points where tension bars within the span are terminated or bent • At the face of the support • At points of inflection at which moment changes signs
  • 28.
  • 29.
  • 30.
  • 31.
  • 32.
  • 33. 5. Standard Hooks (ACI Code section 12.5 and 7.1)
  • 34.
  • 35.
  • 36. Development length of hooked bar ldh : ldh = development length for hooked bar, mm. Ψe = coating factor = 1.2 for all other epoxy-coated bars or wires = 1.0 for uncoated reinforcement 0.24 (Modification Factor) e y dh b c f l d f     
  • 37. • (a) For No. 36 bar and smaller hooks with side cover (normal to plane of hook) not less than 65 mm, and for 90-degree hook with cover on bar extension beyond hook not less than 50mm....................... 0.7
  • 38. • (b) For 90-degree hooks of No. 36 and smaller bars that are either enclosed within ties or stirrups perpendicular to the bar being developed, spaced not greater than 3db along ldh; or enclosed within ties or stirrups parallel to the bar being developed, spaced not greater than 3db along the length of the tail extension of the hook plus bend .................... 0.8
  • 39. • (c) For 180-degree hooks of No. 36 and smaller bars that are enclosed within ties or stirrups perpendicular to the bar being developed, spaced not greater than 3db along ldh ...................................................... 0.8 • (d) Where anchorage or development for fy is not specifically required, reinforcement in excess of that required by analysis ....... (As required)/(As provided)
  • 40.
  • 41.
  • 42.
  • 43.
  • 44.
  • 45. Lap Splices in Tension, lst  Shall be as required for Class A or B splice, but not less than 300 mm, where: • Class A splice................................................... 1.0ld • Class B splice................................................... 1.3ld where ld is the development length
  • 46. Lap Splices in Compression, lsc  Shall not be less than 300 mm   For bars with 420 0.071 For bars with 420 0.13 24 For 21 , Required lap is increased by 1/3 y sc y b y sc y b c f MPa l f d f MPa l f d f MPa       
  • 47.
  • 48.
  • 49.
  • 50.
  • 51. Moment-Resistance Diagram(Bar Cutoff Points)  The factored moment capacity of an under-reinforced concrete beam at any section is: 2 u s y a M A f d          The factored moment resistance of one bar, is 2 0.85 area of one bar ub ub sb y s y c sb M a M A f d A f where a f b A            
  • 52.
  • 53.
  • 54.
  • 55. • Note (a): Portion of total negative reinforcement (As -) must be continuous (or spliced with a Class B splice or a mechanical or welded splice satisfying 12.14.3) along full length of perimeter beams (7.13.2.2). (a) Negative Moment Reinforcement
  • 56. • Note (b): Portion of total positive reinforcement (As +) must be continuous (or spliced with a Class B splice or a mechanical or welded splice satisfying 12.14.3) along full length of perimeter beams and of beams without closed stirrups (7.13.2.2). See also 7.13.2.4. (b) Positive Moment Reinforcement