2. The Foxboro EvoTM
Process Automation System
Addressing the needs across your operation today and tomorrow.
Confidential Property of Schneider Electric 2
3. What are some of your top priorities?
I need to reduce
workload & risk
I need to reduce cost
I need to effectively manage
constant change
Confidential Property of Schneider Electric 3
4. How can we help address these issues?
Tools to improve
engineer workflow &
reduce effort
Products designed to
lower cost and footprint
Future-proof technology you
can take advantage while
preserving your existing
investment
Confidential Property of Schneider Electric 4
5. 5
Let’s talk about how…
What’s new in Foxboro Evo
6. Foxboro Evo Control Editors
Improve engineering workflow
> Dynamic Appearance Objects based on SAMA
- 1st self documenting SAMA based Analog & Embedded Boolean DAOs
- Multiple logic blocks on single canvas
- High fidelity representation of P&ID blocks & data flow
- Preserve engineering effort through reuse & standardization
- Automatic self-updates to objects as changes are made
- Supports user customization
Confidential Property of Schneider Electric 6
7. Foxboro Evo Control Editors
Troubleshoot faster
- Troubleshoot at Loop Level
- Troubleshoot with Analog & Logic Blocks in same view
- Supporting Features
- Find parameter, spare I/O points
- Multiple Logic Blocks Coloring
- Logic Block Memory Polling
- Logic Block Name & Step Numbers, annotation & comments
- Execution Order, Block Status
- Live Data & Live Data Preview
- Supports History & Integration
Confidential Property of Schneider Electric 7
8. Foxboro Evo Control Editors
Easy Upgrades
1. Create Saveall
2. Bulk Data Import
> Import entire CP, compound(s) or simply a single block
3. Generate IDE Database
> Set Preferences – Colors, Line Styles, Live Data …
> Choose Appearance Object – Default, Custom, Dynamic
> Customized Blocks
> Use Built-in Historian Configuration
4. Generate Strategies using Auto layout
> Review log,
> Review Strategies/Layouts,
> Adjust as needed, repeat
Confidential Property of Schneider Electric 8
9. Foxboro Evo Control Editors
Saves hours with bulk reporting & updates
> The Grid Editor allows querying, viewing,
modification & reporting of control block
parameters from within Microsoft Excel.
> Building query
- Sequel dialog builds the query for parameters & specifies
parameters to be returned.
> Formatting a query results
- Simple dialog to add or remove parameters for the grid editor
output report
> Updating database values
- Modified parameter in the cell is highlighted in yellow to
indicate that the value will be written to the Galaxy
- Selected saved modified values pushes the modifications to
Confidential Property of Schneider Electric 9
the Galaxy
Kick the tires! See Live Demo in Trailer
10. Compact 200 Series FBMs
Reduce system cost & footprint
> Increased I/O density per cabinet
- Repackaged 200 Series FBMs in a compact form factor
- Reduced physical I/O volume by 50%
- Increased density of I/O in cabinet by 100%
- Decrease total cost per I/O point by at least 10%
- Marine certified
Confidential Property of Schneider Electric 10
11. Compact 200 Series Family
Reduce system cost & footprint
> New enclosures available:
- G11 termination enclosure
- G13 system enclosure
- 1500 Analog & 3000 Discrete, or any combination I/O
- G14 system & termination enclosure
- 6 FBM types in Phase 1 (released)
- 10 additional types of FBMS in Phase 2 – November 2014
Confidential Property of Schneider Electric 11
12. Field Control Processor (FCP) 280
Increased capacity and performance at lower cost options
- Flexible control system design / implementation
- Fault-tolerant, field-mounted for process control
and alarming functions
- LCD Display and real-time roles and statuses
- Letterbug configurations done directly on module
- Supports multiple I/O types
- Lower cost options with copper wire
Confidential Property of Schneider Electric 12
13. Field Control Processor (FCP) 280
Increased capacity and performance at lower cost options
Control Processor FCP280 FCP270 CP60 CP40
Year Introduced 2014 2004 1999 1995
Main Processor ARM SOC @500Mhz Elan AMD 520 @100Mhz AMD DX5 @133Mhz Intel 486DX4 @100Mhz
Embedded OS 32 bit ARM Cortex 32 bit Nucleus Plus 16 bit VRTX ---
# of FBMs supported 128 128 64 64
Processor Memory 128MB SDRAM 16MB SDRAM 8MB RAM 4 MB
100%
capacity
increase!
Non-Volatile Memory 128 MB Flash RAM 32MB Flash RAM 128KB RAM 64K EPROM
# of Blocks 8000 4000 4000 2000
Block Execution /Second 16000 10000 3400 3200
60%
performance
increase!
Network Connection 100Mbps MESH Fiber or Cupper 100Mbps MESH Fiber Only 10Mbps Nodebus Copper 10Mbps Nodebus Copper
I/O Connection Four ports 2Mbps HDLC Single Port 2Mbps HDLC 10Mbps Ethernet via FCM10Et 268.75 Kbps EIA RS-485
Maximum IPC 231 131 51 (@ >0.5 BPC) 51 (@ >0.5 BPC)
Heat Dissipation 8.5 Watt 8.3 Watt 15 Watt 15 Watt
Cost
savings!
Confidential Property of Schneider Electric 13
14. Flexible I/O expansions & upgrades
Implement today, design when you need
> Intelligent Marshaling (FBM247)
- 100% software configurable I/O
- Designed for ‘uncertainty’
- Faster implementation & start-up
- Reduced equipment costs and footprint
- Reduced spares and inventory
- Reduced engineering and documentation
- 60 sites have implemented worldwide
Before After
Confidential Property of Schneider Electric 14
15. 100 Series Upgrade Program
Simple approach that preserves your existing investment
- Minimum Downtime − hrs vs. weeks
- 40% Cost Savings − No rewiring necessary
- Minimal Configuration Efforts − retain 99% control blocks,
100% process graphics
- Foxboro Expertise − in-house know-how of service,
delivery & engineering teams
Confidential Property of Schneider Electric 15
16. Why upgrade?
Take advantage of the 200 Series product line
- Better environmental specifications: G3, 70 C
- Cyber secure enhanced system
- More choices for I/O signal types
- Longest Lifecycle I/O sub-system
- Improved asset management with Fieldbuses
- HART –Direct Migration without re-wiring!, Foundation Fieldbus, Profibus, Field Device
System Integrators (FDSI), FDT/FDM
Confidential Property of Schneider Electric 16
17. Integrated Control & Safety
Offers CHOICE – levels of integration to lower total cost of ownership
& promote a safer operation with safety system integrity
Kick the tires! See Live Demo in Trailer
- Integrated engineering workflow with TriStation &
Control editors
- Integrated SOE & safety data to be viewed &
historized within Control HMI
- Integrated System Management to view systems
health from one view point
- Unified Communication module offers direct
integration & data exchange between Tricon &
Foxboro Evo controllers across the Control Network
Confidential Property of Schneider Electric 17
18. Integrated Control & Safety
Unified experience with no common mode of failure
- Reduce engineering effort & risk of manual error
- Respond faster with quicker access to system alarm data
- Unified experience with no common mode of failure
- Maintain separate design integrity
- Reduce physical cost and footprint
- Improved visibility and response rate across systems
Kick the tires! See Live Demo in Trailer
Operate Maintain Engineer
Proprietary
Protocols
Integrated
with design
integrity
Confidential Property of Schneider Electric 18
Dedicated Safety Peer to Peer