SlideShare una empresa de Scribd logo
1 de 36
Descargar para leer sin conexión
IN THIS ISSUE
»» One of the Best – Steve Tobey Takes Us Back
to School
»» Best Choices for Addressing 2017 OBC
Changes
»» Best Demo Projects of the Past
»» Best Approaches for Designing Mechanicals
»» Best Way to Renovate – Integrating the Past,
Present and Future
BETTER
BuilderMAGAZINE
the builder’s source
Looking Back and Moving Forward
Simply the Best
ISSUE 08 | WINTER 2014
WWW.BETTERBUILDER.CA
A b r e a t h o f f r e s h a i r .
MAX SERVICE
All mechanical and electrical components are
accessible from the front of the unit.
Heating coil and fan/motor slide out for easy
service.
One of the most extensive warranties in the
business:1-year parts & labour,2-years on parts
only,where applicable.
MAX COMFORT
With the increased efficiency of this optional
Electronically Commuted Motor (ECM),
homeowners will be free to cycle air continuously
with a minimal increase in electricity cost.
Continuous fan operation helps improve
filtration,reduce temperature variations,and
helps keep the air clear of dust and allergens –
making your customers’ homes more comfortable.
Mini Ducted Hi-Velocity Air Handling System
Optional Prioritizing of Comfort Levels with Energy Savings
MAX SPACE SAVER
The MAXAIR fan coil is so compact that it fits
anywhere:laundry room,attic,crawl space,you
can even place it in a closet.
It can be installed in new or existing homes.
It takes less than 1/3 of the space of a conventional
heating and air conditioning unit.
MAX ENERGY SAVINGS
Energy savings,temperature control and comfort
levels are achieved in individual levels of the home
by prioritizing the requirements.This is achieved
by installing optional space thermostats. If any
area calls for heating or cooling, the individual
thermostat allows the space it serves to achieve
optimum comfort and still maintain continuous
air circulation throughout the home.
This method of prioritizing is a great energy
savings measure while offering an increased
comfort level to the home owner.
FLEXAIRTM
DISTRIBUTION SYSTEM
MAX FLEXIBILITY
The supply outlets can be placed in the wall,
ceiling or floor.
Each unit has four choices of locations for the
return air connections.
The FLEXAIR™ insulated 2½" supply
duct will fit in a standard 2"x 4" wall cavity.
Can be mounted for vertical or horizontal airflow.
Can be combined with humidifiers,high efficiency
air cleaners or ERVs / HRVs.
Snap-together branch duct and diffuser
connections.
MAX ELECTRICAL SAVINGS
ECMs are ultra-high-efficient programmable
brushless DC motors that are more efficient than
the permanently split capacitor (PSC) motors used
in most residential furnaces.This is especially true
at lower speeds used for continuous circulation in
many new homes.
1-800-453-6669 905-951-0022519-578-5560613-966-5643 416-213-1555 877-254-4729905-264-1414
For distribution of Air Max Technologies products call
www.airmaxtechnologies.com209 Citation Drive, Units 5&6, Concord, ON L4K 2Y8, Canada
FEATURE STORY
16	 Steve Tobey Takes Us Back to School
	 BY TRACY HANES
	
INSIDE THIS ISSUE
02 	 Publisher's Note: Simple is Best
	 BY JOHN GODDEN	
03 	 The Best Way Forward to 2017
	 BY LOU BADA
04	 Straight From the Hart: Best Demonstration
	 Projects of the Past
	 BY LEN HART	
06	 Best Approach for Right Sized
	 Mechanical Systems
	 BY GORD COOKE
08	 The Best Way to Ventilate
	 BY PANASONIC CANADA AND BETTER BUILDER STAFF
10	 The Real-World Science Behind Better-Built,
	 Better-Performing Homes
	 BY DOW BUILDING SOLUTIONS
13	 Net Zero Housing Design Simulated – Case Study
	 BY MICHAEL LIO AND CEARA ALLEN
22	 The Best Way to Renovate – Integrating the Past,
	 Present and Future
	 BY ALEX NEWMAN
26	 The Best Way to Insulate Basement Floors
	 BY HOWARD COHEN AND BETTER BUILDER STAFF
28 	 The Best New Demo Project	
	 BY DOUG TARRY
31 	 The ARGILE Project: Building Science Research at
	 George Brown College 		
	 BY THE ARGILE RESEARCH TEAM
BETTER
BuilderMAGAZINE
the builder’s source
1
16
ISSUE 08 | WINTER 2014
WWW.BETTERBUILDER.CA | ISSUE 08 | WINTER 2014
3
6
22
PUBLISHER
BETTER BUILDER MAGAZINE
12 ROWLEY AVENUE
TORONTO, ON M4P 2S8
416-481-4218 - FAX 416-481-4695
SALES@BETTERBUILDER.CA
BETTER BUILDER MAGAZINE IS A
SPONSOR OF
PUBLISHING EDITOR
JOHN B. GODDEN
JOHNG@BETTERBUILDER.CA
MANAGING EDITOR
WENDY SHAMI
EDITORIAL@BETTERBUILDER.CA
To advertise, contribute a story,
or join our distribution list, please
contact sales@betterbuilder.ca
FEATURE WRITER
TRACY HANES
CREATIVE
ANNA-MARIE MCDONALD
LITTLE GREEN BAG CREATIVE SERVICES
THIS MAGAZINE BRINGS TOGETHER
PREMIUM PRODUCT MANUFACTURERS
AND LEADING BUILDERS TO CREATE
BETTER, DIFFERENTIATED HOMES AND
BUILDINGS THAT USE LESS ENERGY,
SAVE WATER AND REDUCE OUR
IMPACT ON THE ENVIRONMENT.
PUBLICATION NUMBER
42408014
Copyright by Better Builder Magazine.
Contents may not be reprinted or
reproduced without written permission
obtained at info@clearsphere.ca.
The opinions expressed herein are
exclusively those of the authors and
assumed to be original work. Better
Builder Magazine can not be held liable
for any damage as a result of publishing
such works.
UNDELIVERABLE MAIL
BETTER BUILDER MAGAZINE
12 ROWLEY AVENUE
TORONTO, ON M4P 2S8
BETTER BUILDER MAGAZINE IS
PUBLISHED FOUR TIMES A YEAR BY
2
PUBLISHER’S NOTE
Simple is Best
It’s hard to believe that almost two years have passed since the first issue of Better
Builder. Over this period we have endeavoured to bring our readers simply the best
articles and content. Can you hear Tina Turner singing? I can, and with her song
playing in the back of my mind, I am aware of the fact that when it comes to a lot of
things in life, building included, simple is best.
In this issue, Better Builder takes a look back at a number of the innovations,
products and builders that were successful in their respective markets. They
are identified as the very necessary ingredients to be integrated and executed,
for a smooth transition into 2014 all the while keeping in mind the new code to
come in 2017.
In the feature story of our most recent issue of Better Builder we unfortunately
misspelled the name of the president of Garden Homes. Mr. Ignazio Giardina
is not only a craftsman in the time-honoured manner – he came to Canada 45
years ago as a cabinetmaker – but he is meticulous in his approach to every
home he builds. Mr. Giardina researches thoroughly before he builds a home,
looking for the latest and best materials and methods to make sure the end
product is as durable, and as energy efficient as humanly possible. Anything
that Mr. Giardina believes can improve the end result is tested first on his own
home.
Better Builder, likewise, aims to do its best, providing the latest and best information
about sustainable building practices. Sometimes things slip through, but when it’s
brought to our attention, we appreciate feedback so that we can correct it.
Long time R2000 Builder and friend Steve Tobey takes us back to school on a
project that takes old and makes it new. A new build replicates a century-old
schoolhouse and meets Energy Star 12.1 and becomes part of Project FutureProof.
Lou Bada looks back at LEED/TAP and two years later a demonstration house is
occupied and functioning without any glitches. Lenard Hart reviews 4 demonstration
projects of the past and assesses them on their impact. For almost 25 years CSA
F280 has been used as a standard to design residential mechanical systems;
Gord Cooke outlines the changes in the new revised standards that will result
in the best designs for right-sized heating plants and distribution systems. Alex
Newman reports on builder/renovator Amedeo Barbini who is transforming a 1950
bungalow into a luxury two-story home that reflects
the local value of real estate in Don Mills. Thirty
years after the R2000 program has been introduced,
Michael Lio reports on designs for Net Zero Housing.
Dow Building Solutions is monitoring real-world out-
comes behind better built, better performing homes
under the TEETH Project. Doug Tarry Homes has
achieved a true demonstration of new products in his
Optimum Home. Right-sized heating equipment,
a sealed air-distribution system, and a monitored
basement wall highlight the best examples of how
homes can be better built.
We hope you will agree this issue of Better Builder
is simply the best. JOHN GODDEN
BUILDER NEWS
3
The Best Way Forward to 2017
It has been two great years since I began contributing to Better Builder magazine, and as we look back on past topics of
discussion, I feel this is a good opportunity to look forward to emerging issues as well.
Looming in the distance are changes to the Ontario Building Code’s energy efficiency requirements in 2017. I began almost
two years ago by writing about our LEEP/TAP Discovery Home (ERS 83/HERS 44) which, at the time, helped inform us on the
current redundancies of SB-12 in the OBC. The exercise was also intended to give us insight into what would be required to
achieve the projected energy conservation goals of the next Code cycle. At the time, we utilized just about every off the shelf
premium technology at our disposal to meet the expectations of the 2017 code. Technologies such as: upgraded right-sized
mechanicals (combination heating
system, high efficiency HRV and
bathroom fans), renewable systems
such as, Drain Water Heat Recovery,
building envelope details with insulated
sheathing, high density and foam
insulation and Zone C windows,
improved air barrier detailing, electrical
savings with ECM motors and efficient
lighting (LED and CFL), water
conservation with a re-circulating hot
water system and dual flush toilets. It
is of import to note that all systems are
running well in the Discovery homes
we have worked on to date, and our
homeowners have not run into any
problems…as well they shouldn’t, given
that these are all proven technologies.
Looking forward, future proofing, in the form of rough-in grey water recycling and solar ready for PV are certainly on the
table for serious consideration in discussions concerning sustainable building practices. Further, these systems could
have been utilized in the LEEP/TAP home. And, as we’ve seen, accommodations are being made in the OBC in regards
to grey water recycling. However, I believe we are approaching the limit of where off the shelf technologies will give us
a reasonable return. Having said that, some wiggle-room still exists by lowering further still air infiltration and increasing
mechanical efficiencies. Unfortunately, they will only take us so far.
Re-use and renewable technologies will become more relevant, but not until the technologies have completely matured
and are economically viable, especially in cases where freshwater, waste and storm water are concerned. I believe, for the
OBC to move forward, a broader perspective will need to be taken in regards to water and its impact on building efficiency,
energy consumption and infrastructure.
Finally, there must be a value proposition (and perception) for our customers; affordability is always an issue. This will
require people with common sense and goodwill in this industry and in government, working together towards a common
goal. Flexibility and innovative thinking in terms of the societal costs and benefits of building more efficient homes will be
paramount in the coming years, in contrast to the conventional thinking we’ve experienced thus far.
ISSUE 08 | WINTER 2014
LOU BADA
LOU BADA IS THE CONSTRUCTION & CONTRACTS MANAGER FOR STARLANE HOMES
4
Straight from the Hart
BEST DEMONSTRATION PROJECTS OF THE PAST
It has been two years since Better Builder magazine was created, taking the place of its predecessor Sustainable Builder
magazine, and I thought this would be an opportune time to review some of the many projects covered over these last few
years. Personally, I am grateful for the plethora of projects I have been involved with, and take pride in how the industry has
evolved to produce better homes. Unfortunately, many of the challenges we faced still remain unresolved.
For the second issue of Sustainable Builder magazine (summer 2009) we had the three elected heads of the big HBAs
on our cover (BILD, Ontario and Canada). All three were green-builders so we titled the issue, Everybody’s Green. At
the time, we thought that leading positions were being given to green-builders simply because they were green builders.
Now it seems as though green-building is more ubiquitous than ever, no longer a badge of distinction, but rather that
it is something that everyone should be implementing. The changes to the building code have certainly been a factor, as
well as the influence of the market. Back in 2009, the ever insightful Stephen Dupuis talked about the ten green-guys;
the few key movers who were behind all the green-projects in the industry. Today, there are literally hundreds of green-
professionals; builders, engineers, Energy Star compliance officers, etc.
What it means to be green or sustainable is essentially a contested concept. Like democracy or beauty, the definition
is arbitrary and changes as frequently as debates continue as to what should or shouldn’t be included. Lately, it seems
as though too much has been included, thus diminishing the concept’s value. Energy Star has always been a double-
edged sword for me. It was the program that got production builders thinking about building above code, but it was
clearly a lower level achievement compared to R-2000, LEED Platinum, Net Zero, or Passive House. It should come
as no surprise that the Green/Sustainable/Energy Efficient label does not carry the weight it used to. With thousands of
homes being built to the current code, getting the Energy Star label was far too easy, mostly because they were enrolled
under the old standard.
Consumers expect the Energy Star label to have meaning, and under the new standard it will again. However, the
market for more energy efficient homes seems to have hit a plateau despite the fact that climate change and rising
energy costs still persist. Perhaps new homes are too far ahead of existing homes when it comes to energy efficiency.
For example, I used to live in a LEED Platinum home, rated 85 on the EnerGuide scale. Now, I live in a 1920s full-brick
house with some modest insulation upgrades. My utilities bills are triple what they were in the LEED house; from $95 to
$315 per month. Yet I live in Bloor West now instead of New Market, and my commute is ten to twenty minutes. Since
my commute has shortened, I drive much less and my overall carbon footprint is about the same. For me the question
is simple: is it worth the extra monthly utility costs to live where I live? In short, the answer is yes.
Going forward, the challenge seems to be how to get an individual to invest $20,000 or more on a retrofit upgrade
that will save them only $150-$200 per month. Despite how far we have come in terms of new technologies and new
homes, the old payback problem still exists.
Aside from the Energy Star program, I was lucky enough to have some involvement with four significant Green Projects
over the last few years that I would like to reflect upon in retrospect.
Rodeo Fine Homes and the Town of Newmarket – This project arose when the town offered a discount on a large undeveloped
piece of land, on the basis that builders would meet the conditions of Platinum rating. Rodeo Fine Homes won the bid to build
the subdivision and proposed to meet the standard using the LEED for Homes rating system. The result was 34 comfortable,
quiet, highly efficient homes in a quiet part of Newmarket. To get to the LEED Platinum rating there was a large reliance on very
advanced technology, which resulted in plenty of maintenance issues, but also significant challenges in finding knowledgeable
trades to service the homes.
Ultimately, the project was ahead of its time, especially for the area, where code-built monster homes tend to be the main
competition. I bought one, and upon resale, I was unable to recoup any above market pricing for the green upgrades, but still it
was by far the best performing home I have ever lived in. From an industry perspective, I am not sure other builders are looking
to this model, not even Rodeo is building like this anymore.
BUILDER NEWSBUILDER NEWS
LEN HAR T
5
NOW House –This was a “Net Zero-inspired” retrofit to a post-war CMHC bungalow. At the design charette there was extensive
focus on how to produce an affordable high efficiency retrofit, but sponsorships changed the project to be more about what is
possible than what is feasible. A real homeowner got significant benefits that improved his small home’s energy efficiency, but it
was not a good template for others. It was too expensive, and for all that money it did not add any square footage.
The retrofit itself seemed to pale in comparison to the well packaged and well promoted retrofits in the road show that followed.
In the end the retrofit was dominated by the sponsor’s offerings. It was too much money to spend for an energy retrofit. The
promotional road show was successful as a sales tool for some retrofits.
Green Home Makeover – A TRCA neighborhood level initiative, in which a dedicated community resource person promoted
energy and water conservation to a community with a contest to give away a home retrofit to one lucky resident. The
project addressed the issue of getting home owners to retrofit their homes and served as a demonstration project for
the community. However, other than the free makeover winners, nobody else really did any significant retrofit work.
The key partners in this project were local and regional governments, who along with the TRCA were most interested in
watershed issues and managing run off. Ultimately that is a tough sell with very little payback. The energy retrofit was
added to round out the offerings, but it did not result in much uptake.
The Archetype Sustainable House – A TRCA sponsored design contest aimed at showing the future of home building.
Once a design was chosen, the TRCA partnered with BILD to construct the demonstration homes at the Kortright Centre
using donated materials and volunteer labour. Two unique and informative demonstration homes now exist and are regularly
toured. The partnership between TRCA and BILD was a significant achievement and a major part of Stephen Dupuis' lasting
legacy. The home construction process suffered from a lack of resources, despite significant contributions from BILD
members, many compromises had to be made and some decisions were based purely on what was available.
The architects who designed the homes were quite new to the industry, so there were some growing pains that were
compounded by the volunteer build model. This put a lot of pressure on those actually trying to get the homes built,
such as Alex Waters, Larry Brydon, and Fred Serrafero. In the end, the project was a significant achievement that still
has relevance and is still toured today, but did it change anything?
All of these projects aimed high and involved much negotiation and compromise, all had multiple strategic collaborations
and multi-sector partners (including governments, associations, and sponsors), and all tried to effect change in the
way we build and retrofit homes. Each was successful in its own way, but each also gave us a learning opportunity. In
looking forward, I hope we see projects that continue to advance green-building. If pressed, I would say the four areas
where we should see some real advances are: building envelopes, production quality, smart technology, and deep retrofits…
but these are for future issues.
ISSUE 08 | WINTER 2014
BUILDER NEWS
LENARD HART IS THE BUSINESS DEVELOPMENT DIRECTOR AT GREENSAVER A NOT-FOR-PROFIT ENVIRONMENTAL ORGANIZATION FOCUSED ON RESIDENTIAL
ENERGY EFFICIENCY AND CONSERVATION PROGRAMS. HE WAS ONE OF THE DEVELOPERS OF THE ENERGY STAR FOR NEW HOMES PROGRAM IN ONTARIO AND THE
FORMER PUBLISHING EDITOR OF SUSTAINABLE BUILDER MAGAZINE.
Project Pros Cons Learning
Grade
Newmarket LEED
Platinum
Showcased ground breaking technology,
Town was a partner
Too far ahead of the curve, and too much
tech for home buyers
A-
NOW House retrofit Responded to specific homeowner
need, promoted widely
Lost its way when sponsors offered more
than needed
C+
Green Home Makeover Community based, addressed energy,
water draw and run off
Free upgrade lead to little community
uptake, despite all the efforts
C-
Archetype BILD/TRCA partnership, hundreds of
tours, Ryerson monitoring
Redundant showcase systems, unclear
how it changed building
B+
BUILDER NEWS
6
I have been fielding calls recently from manufacturing folks with southern accents asking about changes they have heard
about with respect to the need for smaller furnaces in Canada. They are referring of course to the publishing of the new
CAN/CSA F280 Standard “Determining the Required Capacity of Residential Space Heating and Cooling Appliances” and
the impact it will have on the size of furnaces that will be needed in Canadian homes when the standard is referenced
in building codes and adopted as standard practice in the coming months. The US furnace manufactures I am speaking
to seem surprised by this “sudden” change, but they shouldn’t be. After all the old F280 Standard was written in 1990
and when it was written there were notes in the appendices suggesting the standard needed better ways to handle the
emerging trend at that time for tighter homes with more efficient ventilation systems. HVAC designers will know that in
the current 1990 CSA F280 these two components, air leakage and ventilation, typically account for as much as 40-50%
of the overall design heating load for a home. A short 23 years later, the new standard does indeed address the fact that
all new homes are much tighter than the old standard ever anticipating being possible and heat recovery ventilation is
now a common component in new homes and in 1990 there was no allowance for this type of device. Combine that with
updates to the standard in the way foundation heat loss is modeled and recognition of the new window glazing options
now available to builders that optimize both heating and cooling impacts and it should be no surprise at all that a heating
and cooling system designed under the new CSA F280 should be significantly smaller than systems designed using the
algorithms in the existing standard.
That said, it does take some getting used to when you consider the table below showing the results for a 2 – storey, 2200
square foot home in Newmarket, ON built to current Ontario Building Code requirements, using Package J insulation and
mechanical system requirements under the old and new standard.
It means a home that used to get a 70,000 BTU/Hr furnace now needs only a 40,000 BTU/Hr model. Of course, most
furnace manufactures do have 40,000 – 50,000 BTU/Hr models. The real issue for manufacturers is the recognition that
as many as 50% of homes built in Canada last year were smaller multi-family, attached dwellings that, using the new CSA
F280, have design heat losses well below 30,000 BTUs/Hr. As Doug Tarry of Doug Tarry Homes in St. Thomas, ON
reported in a previous article, this new sizing validates why many builders are having problems meeting the comfort
expectations of their customers. That is, if we were assuming a house needed a 70,000 BTU/Hr furnace on the coldest
day of the year and it really it only needs a 40,000 BTU/Hr furnace you can expect issues. It means that the furnace runs
just half the time on a cold day and rooms that have higher than average rates of cooling, like a room over a garage, that
room is going to be cold. Homeowners think this cold room scenario means the furnace is too small, while the new CSA
F280 sizing would confirm the issue is the furnace is too big and thus doesn’t run long enough to ensure adequate heat
flow to all rooms in the house.
Of course, if homes in Canada need smaller furnaces, you can imagine that homes in milder US climates would also be
affected, so why haven’t US manufactures seen this issue there? There may be two reasons. First, those milder climates
don’t result in the high rates of cool down that we experience in cold weather, so while some rooms in a home might be
cooler than others, the effect isn’t particularly dramatic. Second, zoning of HVAC systems in the US has become much
more common than in Canada, primarily to solve summer cooling comfort expectations, but it will help balance winter
temperatures as well.
Best Approach for Right Sized
Mechanical Systems
GORD COOKE
Total Heat Loss BTUs/hr Air leakage component of
Heat Loss BTUs/hr
Total Heat Gain BTUs/hr
Current CSA
F280
55,425 13,225 31,250
New CSA F280 33,875 4,020 26,150
Of great interest, while the US manufacturers will someday respond to this need for
smaller furnaces, one Canadian manufacturer has already stepped up. Dettson Industries
in Quebec, a long standing excellent boiler manufacturer, has entered the forced air industry
at just the right time with a full series of high efficiency, multi-stage furnaces, but most
importantly one that has a smaller capacity. In fact, as Doug Tarry reported, they have
installed a unit in St. Thomas that has a capacity of just 30,000 BTUs/Hr. It is nice to see
Canadian manufactures supporting the initiatives of Canadian builders.
May I suggest that this winter will be a great time for builders and their HVAC contractors
and designers to recalibrate their thinking of what constitutes a properly sized furnace.
Starting tomorrow, install a thermostat on at least one of your homes that can monitor
run times of furnaces. Many commonly available thermostats can do this, like the web-
based stat EcoBee. Now you check over this winter just how often the furnaces you are
using now are operating during the coldest periods and this will help you accept the
reality that smaller furnaces with smaller duct work can improve comfort, save space and
perhaps be even just slightly less expensive to install – a great win-win from all your hard
work to improve the energy efficiency of your homes.
7
BUILDER NEWS
ISSUE 08 | WINTER 2014
Clears
the room
faster than
Charlie
Sheen.
Vigör is worth a tweet or two.
Our lowest priced HRV/ERV
delivers powerful ventilation for
small spaces. It’s so easy to
install, you’ll wonder why you
ever chose anything else.
Now that’s winning.
Perfection. Cubed.
Visit vanee-ventilation.com
to learn more.
VEN_Ad_MB_Jun2311.indd 1 11-06-24 9:29 A
GORD COOKE IS THE PRESIDENT OF BUILDING KNOWLEDGE CANADA
DETTSON RIGHT SIZED FURNACE INSTALL AT DOUG TARRY HOMES.
ATTENTION:
HOME BUILDERS
Introducing a revolutionary
new product that eliminates dirty,
dusty floor vents during home
construction. Forever.
Our product is made from recycled
materials. Made in Canada.
by preventing dust, dirt, and garbage from
entering the duct -work.
on to detail
= enhanced customer satisfaction.
design.
NEW PRODUCT
www.protecvent.com
905.532.0722
BUILDER NEWS
The Best Way to Ventilate
In the world of bathroom ventilation fans there are a plethora of options available to
builders and consumers, but which one to choose? Aside from expelling moisture and
odour, the criteria for this decision revolves around three main areas; the products
affordability, its energy efficiency and how much noise it produces. Panasonic has striven
to meet these additional criteria with their line of bath fans called Whispergreen DC.
Not only is this line of fans 30% less expensive than most other models, its enclosed
DC motor ensures a longer life-span (rated for 60 000 hours of continual use) and
comes with a six-year warranty.
This line of fans has earned the highest performance rating from the US EPA ENERGY
STAR program, the most efficient label, and two of the variable speed models have the
distinction of having the highest efficacy rating on the entire list, at 23.3 CFM/W. This level
of efficacy far exceeds the ENERGY STAR minimum of 1.4 CFM/W for this CFM flow.
One of the many features that have made these fans the industry performance leaders
for the past six years is the built-in Smart-Flow technology that maintains a constant level
of airflow over a wide range of static pressures. Each fan has a chip that measures
the fan RPM and amperage draw many times per second, and determines if the fan
needs to speed up or slow down to maintain the chosen airflow rate. This means
that if 50 CFM airflow is chosen, the installer or tester will see 50 CFM (+/-5-
10%) over a range of zero static to upwards of 125 Pa. This is not a static setting
or single-time commissioning; this technology controls the airflow even with a
drastic change in static pressure caused by wind or stack effect or by other fans
discharging into the same shaft in a multifamily building. They even maintain that
airflow under negative pressure. The fans are constantly sampling and adjusting the
speed to maintain the set airflow for the life of the fan.
When the fan is turned off- or the optional motion sensor detects no movement – it will
automatically wait a predetermined period of time and then drop back down to the base-
line CFM level. This not only saves on energy consumption, but minimizes the amount of
noise it produces.
Scott Ingram, a Toronto resident, had the Whispergreen DC installed in his three-bed-
room Leaside home just under a year ago and couldn't be more pleased with the result.
“We got it for our en suite bathroom on the third floor of our house,” Ingram said. “The
thing is so quiet the only way to tell that its on is by the green light on the LCD monitor...
Not only does it clear all the moisture and odour from the bathroom within minutes, we
even use it when we cook because it clears those odours too, from three floors away!”
The product was recommended to him by an industry expert and Ingram says that he
would buy it again, and thinks everyone should have one.
Panasonic offers five single speed Whispergreen models, the 50, 80 and 110 CFM
fan-only models and two CFL light versions of the 80 and 110 CFM models. Whether it
is a commercial, multifamily, or single-family project, these single speed DC fans are a
great choice. In one condo project in Hawaii, 950 50 CFM fans were installed in a 37-
storey building. The Smart-flow technology of these fans meant that the HVAC con-
tractor provided 50 CFM of exhaust in every unit, no matter what floor and no matter
how many were discharging into these very tall fire-rated shafts. The Test and Balance
contractor had hardly anything to adjust.
PANASONIC CANADA AND
BETTER BUILDER STAFF
Providing effective
ventilation solutions
for today’s high
performance housing.
Do you really want to install the same old fans in your next project?
You can differentiate yourself as a sustainable builder by choosing Energy Star qualified Panasonic WhisperGreen™ ventilation fans.
WhisperGreen™ fans are designed to provide both continuous whole house and spot ventilation for improved indoor air quality.
The automatic variable speed control allows the fan to run continuously at a pre-set lower level for whole house ventilation. Turning
on the switch or activating the motion sensor elevates the fan to a maximum level of operation for effective spot ventilation.
Quiet, powerful and energy efficient, Panasonic ventilation fans are also Energy Star, LEED, and ASHRAE 62.2 compliant making
them a wise choice in sustainable building.
Learn more by visiting panasonic.ca or email VentilationFans@ca.panasonic.com, or call 1-800-669-5165.
*Comparison with ENERGY STAR requirement of minimum efficacy level of 1.4 CFM per watt for 10-80 CFM fans and 2.8 CFM per watt for 90-130 CFM fans.
BUILDER NEWS
10
BUILDER NEWS
DOW BUILDING
SOLUTIONS
The Real-World Science Behind
Better-Built, Better-Performing
Homes
When it comes to residential home construction, Dow knows that homebuilders and remodelers want to be 100 percent
sure that the products and solutions you’re using are increasing the comfort, durability, quality and value of the homes
you build. Part of our job at Dow Building Solutions is to ensure that we understand the science behind the building and
use that knowledge to help YOU create homes that meet or even outperform Ontario’s building codes. By helping you
outperform codes, we can help you create homes that provide long-term comfort, lower utility bills and durability for your
home buyers, an enhanced reputation for you and growing bottom line for your business. Backed by The Dow Chemical
Company’s 100+ years of experience, we believe in the importance of testing our insulation and air sealing solutions and
understand that our testing must extend beyond the lab into where it matters most – the real world.
TWELVE ENERGY EFFICIENT TEST HOMES (TEETH) PROJECT
There is a real-world case study
taking place right now in Midland,
Michigan. Spearheaded by Dow
Building Solutions and Cobblestone
Homes of Saginaw, Michigan, the
Twelve Energy Efficiency Test
Homes (TEETH) Project was several
years in the making. The goal of
this project is to create the first-
ever forum for real-world, real-
time measurements that track and
capture data of high-performance
homes. The project consists of 12
homes, built in Midland, MI, U.S.
Climate Zone 5/6 (equivalent to
Ontario’s <5,000HDD Climate Zone),
that are not just test facilities, but
homes in which real families live.
The TEETH neighborhood is made up of four different energy performance insulation and air sealing packages and three
different floor plans. Each of the four energy performance packages features a different combination of insulation and air
sealing improvements, including continuous insulation, closed-cell spray foam insulation and insulating foam sealants*.
Home construction was completed in 2011 and the full study launched in fall of 2012 after the last home was occupied.
ENERGY PERFORMANCE DESIGN PLAN BUILDING CODE MET
Baseline Performance Minimum Cost HERS 82 Meet 2006 IECC at lowest possible price point
2012 Energy Performance Minimum Cost HERS 57 Meet 2012 IECC at lowest possible price point
2012 Outperformance Home HERS 57 Meet 2012 IECC building science best practices
Beyond Code: Renewable Ready HERS – mid 40s Exceed 2012 IECC Renewable ready
BUILDER NEWS
ENSURING VALIDITY
To ensure the validity of the study, each home was uniformly built to
exacting standards designed to mitigate variances, including orientation
to the sun and grade. The 12 test homes are comparable in size, floor
plan and all other key features with the exception of the insulating and
air sealing systems. It is important to note that the families living in the
TEETH homes are not aware of which energy performance model home
they are living in. This allows for residents to conduct their normal
energy consumption habits without awareness of the energy
performance of their dwelling, which helps to ensure the data
collected is unbiased. With the data collected, we are able to
accurately test how building products and systems behave together.
GATHERING DATA
The TEETH Project represents the country’s first active subdivision
dedicated to the purpose of collecting and analyzing building
performance data. Each home has a Data Acquisition Box in its
basement to collect information relating to energy consumption,
humidity, moisture levels, heat flow, and temperature – all key
contributors towards a homes energyefficiency.
YEAR-ONE DATA ANNOUNCED IN FEBRUARY
AT 2014 INTERNATIONAL BUILDER’S SHOW IN
LAS VEGAS, NV
While the homes were built in 2011, they all weren’t fully occupied
until the summer of 2012, so our research didn’t begin until the winter
season of 2012-2013. Now that we are one year into the project we
have the first year’s data realized. Dow is currently analyzing this data
and is scheduled to present our findings in a presentation at the 2014
International Builder’s Show, February 4-6 in Las Vegas, NV.
The TEETH Project is just one example of Dow’s ongoing commitment
to gathering realworld data that allows homebuilders and homeowners
to see how building a better performing home benefits both builders
and homeowners. Building Outperforming Homes helps you, the
builder, differentiate yourself from your competition and grow your
business and reputation by offering homeowners long-term comfort,
efficiency, savings, and overall home durability. For more information
on Dow’s TEETH Project and more of our building science real world
proof, please visit our website or contact Dave Kelly, (416)460-9876,
Senior Building Envelope Specialist for Ontario.
*Although built using US building codes as a reference point, these
homes will provide data points showing the value of insulation & air
sealing upgrades throughout the United States and Canada
®TM
Trademark of The Dow Chemical Company (“Dow”) or an affiliated
company of Dow
11ISSUE 08 | WINTER 2014
The Power-Pipe®
uses outgoing warm
drain water to pre-heat
incoming cold freshwater
in Residential, Commercial
and Industrial, thereby
reducing energy costs.
TURN THAT WASTED ENERGY
INTO $AVING$ WITH THE
www.power-pipe.com
Saving Energy Intelligently
E N E R G Y I N C .
Developed and Manufactured by:
LOWER ENERGY BILLS.
GREAT RETURNS.
Drain Water Heat RecoverySystems
H O W I T W O R K S
®
GreenBuild 8x10 Pstr3_Print.pdf 5/7/12 10:34:54 PM
www.inlinefiberglass.com 1.866.566.5656
INLINE FIBERGLASS LTD.can help your clients meet their energy and thermal
performance targets in most cases without the use of special designs or expensive
glass options. Call us to discuss your next project and find out why our windows are
chosen often for LEED designs, Passive Homes, Healthy Homes, Health Centers, Hospitals,
Schools, Fire Stations, Hydro Offices, Retirement Homes, Nursing Homes . . .
MEMBER/MEMBRE
Unison Community Health Centre / Architect: Hilditch Architect / Constructor: Buttcon Limited
INLINE FIBERGLASS LTD.
Covering all your angles, SB10, SB12, Energy Star, NFRC,
High Performance Window Products
13
Many across North America hope to see homes built to Net
Zero standards by 2030. The idea of a Net Zero Energy (NZE)
home is that it employs enhanced energy efficiency design
strategies to cost effectively reduce energy needs, while
meeting those needs with renewable energy technologies.The
result is a building that consumes equal to or less energy than
it produces on an annual basis.
The federal government, through the ecoENERGY Innovation
Initiative (ecoEII), is funding a cross-Canada demonstration
project of Net Zero homes in the context of housing
production. The project focuses on affordability and market
acceptability of Net Zero homes. The project proponent,
Owens Corning Canada, is working with five builders in four
provinces to build at least 25 Net Zero homes.
To build a Net Zero home, the first efforts focus on
conservation by maximizing the envelope and air tightness
levels, and by including high performance mechanical
systems. Reduction in energy consumption means that
lower energy generation technologies are required. Energy
efficient technologies are generally much less costly than
those that generate energy. It makes little sense to install
hundreds of photovoltaic (PV) panels on a leaky and poorly
insulated house to achieve a Net Zero balance.
To understand the impacts of energy conservation measures,
such as upgrading the envelope or reducing air leakage, the
buildABILITY team modelled various scenarios in HOT2000
using the Ontario Archetype house. The goal of the exercise
was to see how much the calculated annual energy
consumption of the Archetype House could be reduced
before renewable technologies were considered. Various
levels of insulation were examined for the ceiling, walls,
basement walls, and underneath the slab. Several U-values
and solar heat gain coefficients (SHGC) were investigated
for windows. A number of high performance mechanicals
were considered and modelled. The systems that were finally
selected are shown in Table 1.
The modelling exercise was intended to see how much the
annual energy consumption could possibly be reduced; the
simulations did not consider costs.
The NZE homes that will be built for the ecoEII project use the
new EnerGuide Rating System for New Homes to measure
energy use, and in many cases use the new R-2000
requirements as the jumping off point to achieve Net Zero.
The new R-2000 program includes reduced base loads,
electrical base loads are 16 kWh/day, domestic hot water
loads are 143 L/day, and the occupant numbers are reduced
to two adults and one child. These were incorporated into
the buildABILITY modelled scenarios before the upgrades
packages were investigated.
The first upgrade to be modelled was for the ceiling. The
ceiling insulation was upgraded to two layers of R-40 batt
for a total effective R-Value of R68.
The walls were modelled as double stud construction, each
with R22 batt, and with exterior insulating sheathing for an
effective R-Value of R40. Double wall construction is not
popular in tract housing, however it was modelled because
of the high R-Values that can be achieved; other alternatives
exist to achieve high R-Values.
The basement walls were modelled using a combination of
insulating sheathing (2” extruded polystyrene) and R22 batt
for an effective R-Value of R27. Extruded polystyrene at 2.5”
thickness (R12) was provided under the entire basement
slab.
The windows were upgraded to triple glazing with two low
ecoatings (e= 0.1), filled with krypton, and modelled with an
insulated spacer. This window type represents a U-Value of
0.16 and a SHGC of 0.41.
The air changes per hour (ACH)were reduced to 0.75. This
level of air tightness has been demonstrated and achieved
using the Owens Corning’s CodeBord Air Barrier System.
All five tract builders participating in this ecoEII project will
be using the CodeBord Air Barrier System as a standard in
their net zero housing designs.
The upgrades to the envelope accounted for an estimated
30% reduction in annual energy consumption.
For the mechanicals, an 88% efficient HRV, a 96% AFUE
furnace and a tankless water heater were modelled. A drain
water heat recovery unit was modelled using the custom
spreadsheet provided to the ecoEII project by Natural
Resources Canada. The 120” unit has a 72% efficiency rating.
The upgrades to the mechanical systems accounted for an
estimated 20% reduction in annual energy consumption.
In total, both envelope and mechanical system upgrades
MICHAEL LIO AND
CEARA ALLEN
INDUSTRY NEWS
Net Zero Housing Design Simulated
– Case Study
ISSUE 08 | WINTER 2014
INDUSTRY NEWS
1414
resulted in an estimated 50% total reduction in annual energy
consumption. The final scenario would require approximately
42,000 MJ of energy annually – a reduction of over 88,000
MJ from the Archetype House.
Of the ten upgrades added to the model, the three upgrades
that produced the greatest reductions were the R40 walls
(8%), the triple glazed windows (8%), and the improved air
tightness to 0.75 ACH (9%). While these are only scenarios,
which do not provide information on the cost of these
upgrades, and do not represent the final designs from the
ecoEII builders, it does provide insights as builders consider
the road to Net Zero.
The five builders participating in the ecoEII Net Zero project -
Construction Voyer (Laval, Quebec), Mattamy Homes Limited
(Calgary, Alberta), Minto Communities (Ottawa, Ontario),
Provident Development Inc. (Halifax, Nova Scotia), and
Reid’s Heritage Homes (Guelph, Ontario) - have been under-
taking similar exercises for each of their home designs over
the last few months, using their HOT2000 outputs to modify
and improve their Net Zero designs. The ecoEII builders each
have very different housing forms. Each builder is designing
a customized Net Zero package that is tailored to not only
the housing forms, but also to the capacity of local trades,
the local cost of labour and materials, and the local climate,
among many other factors.
Recently, the builders, consultants, and Owens Corning
Canada, participated in the Net Zero North American
Leadership Summit in Irvine, California. The regional
teams presented their implementation plans including their
designs,conservation measures, and energy generation
strategies. They also presented the current challenges they
are dealing with on their road to Net Zero. The presentations
were well received by the summit participants, and generated
a lively discussion.
Construction of the Net Zero homes is expected to begin in
the Spring of 2014, and will be completed by 2016.
Funding for the project is being provided by the federal
government’s ecoENERGY Innovation Initiative (ecoEII)
program, Owens Corning, and in-kind contributions from the
building industry. More information about can be found on
the project website: http://www.zeroenergy.ca
For more information on the project, please email Candice
Luck, candice@buildABILITY.ca.
TYPE UPGRADE ESTIMATED
ANNUAL ENERGY
CONSUMPTION
(MJ)*
% REDUCTION*
Benchmark Ontario Archetype House 130,000
Base Loads Base Loads: reduced to new R-2000 levels 107,000 20%
Envelope •	 Ceiling: R40 batt x 2, gypsum ceiling (=R68)
•	 Walls: brick, air space, CodeBord, double stud with R22 batt x2, gypsum
(=R40)
•	 Basement Walls: concrete, CodeBord, R22 batt, gypsum + slab CodeBord
(=R27 + R12)	
•	 Windows: U0.16 + SHGC 0.41 (triple glazed, 2 low e.1 coatings, 9mm
krypton, insulating spacer, picture window, fibreglass frame)	
•	 Air Tightness ACH 0.75
66,000 30%
Mechanical •	 DHW: tankless water heater EF.94
•	 DWHR from Spreadsheet
•	 HRV @ 88%	
•	 Furnace AFUE @ 96%	
42,000 20%
*Numbers are approximations of simulated values
It should be noted that that this is a case study done by buildABILITY; costs were not considered and this modelling is not
representative of the final designs of the builders. The ecoEII builders each have different housing forms and customized
net zero packages are being designed.
MICHAEL LIO IS PRESIDENT OF BUILDABILITY CORPORATION, MICHAEL@BUILDABILITY.CA
CEARA ALLEN IS MANAGER, TECHNICAL SERVICES, BUILDABILITY CORPORATION
17ISSUE 07 | FALL 2013
Features
rHVCA
ResidentialHeatingVentilation
ContractorsAssociation
rhvca.com | info@rhvca.com | 905-264-9967
heart
The
of your
home
Don’t leave the health of your home’s
most valuable asset to chance. Trust only
a RHVCA member to design, install and
service your heating, cooling and ventilation
system. Our members represent the
highest standards of training, certification,
and expertise in the HVAC industry.
16
One of
the BestSteve Tobey Takes Us Back to School
BY TRACY HANES
17
When the house at 296 Goodfellow Rd. in Codrington was
destroyed by fire in January 2013, a couple not only lost
their home. The local community lost a piece of its history.
The century-old building in the Brighton area had originally
been the one-room Mount Olivet Public School SS 25 that
many local residents had attended as children. It was used as
a school until 1967 when local centennial schools were built.
The current owners, one a retired school teacher, bought
the schoolhouse in 1985 and it became their personal home
until the fire. A porch and addition were added to the original
schoolhouse. While the fire left the exterior walls standing, it
destroyed the inside of the house and its contents.
“When the house burned, an icon of the community was
gone,” says Stephen Tobey, Gordon Tobey Developments of
Brighton, an award-winning builder. When his company was
called on to design and build a replacement home for the
site, the challenge was to honour the past while providing the
homeowners with a modern new abode.
18
The house, called the Painted Maple, is 2,450 square feet, just slightly larger than the home it replaced. The design
accommodates one-floor living for the retiree owners with master bedroom and ensuite on the main floor, with additional
two bedrooms and bathroom in the loft above to accommodate their daughter-in-law and grandchild who come for
extended stays. The kitchen, dining area and great room combine to form an airy, spacious single open living space. The
great room and front entry hall have high ceilings open to the loft cat walk above. The main floor also includes a
den/office and a large mud room that is close to the detached garage.
The front of the home features symmetrical proportions, a large covered porch, a steep gable over the front door, ginger-
bread trim and black shutters. The red brick has Flemish bond detail reminiscent of the red brick from the schoolhouse.
The original bell from the school was salvaged and mounted on a structure on a corner at the front of the lot.
The last teacher to teach at the school lives in a farm across the road and remembers ringing the bell at lunchtime for the
children, that also served as a signal to local farmers in their fields that it was time to stop work and break for food.
“The property had mature trees, a driveway and pool and we put the new house where the old schoolhouse had been,”
says Tobey. “But the old schoolhouse didn’t have views where views should have been.”
Now, low-E argon windows that minimize heat loss in winter and heat gain in summer allow for generous natural light and
provide views of the surrounding fields and the pool. The windows are single and double-hung styles chosen for their
traditional appearance.
The homeowners had lived with a leaky building envelope and had only a crawlspace with dirt floor under their school-
house home. Their energy bills had been steep, so a priority was comfort and energy efficiency for the replacement home.
As an R2000 builder, Tobey knew his company could deliver the quality, design and superior energy efficiency the home-
owners required. The new home was built to Energy Star standard and well above Code.
Because his company provides a comprehensive energy package to its clients, Tobey says that freed the homeowners
from having to make even more choices. “They had to make so many decisions and it can be overwhelming. By using us
“We wanted the new
house to pay homage
to the style of the old
schoolhouse and fit into
the local agricultural
community,” says
Tobey. “We decided on
a home similar in style
to a traditional Ontario
farmhouse style. But
inside, the homeowners
wanted a modern,
open-concept layout.”
Discover the Difference—experience
our customer focused building process that
fosters confidence and peace of mind.
www.tobeydevelopments.com
613 475 0618
Brighton.On
LIVE YOUR DREAM
20
as designers and builders, we can give them the energy
package and say ‘this is what you’re getting,' which is a
bonus for them.”
The Painted Maple was not built to R2000 specifications
although Tobey Developments has built many homes
to those criteria. In January 2014, R2000 buildings will
be required to be 50 percent more energy efficient than
Code-built ones, with a building envelope 25 percent
tighter. The best-in-class standards will address air
conditioning, micro-power generation, solar thermal,
etc. which will add significant cost for the home buyer.
Tobey is not certain his company will pursue the new
R2000 for its homes, though the company will continue
to provide the same high level of energy efficiency and
quality construction methods as it has been. Tobey’s
building his own house to the new R2000 criteria “to
see what we think of the whole thing” and to determine
whether it will justify the added expense to achieve
the stringent new benchmark – and if it’s something
customers are willing to pay for.
The Goodfellow Rd. home’s HVAC system includes a
high efficiency propane furnace and Energy Recovery
Ventilator with DC motors, and a 15 SEER air conditioner
to reduce consumption of electricity. All lighting uses
Energy Star certified bulbs. The tightly sealed building
envelope boasts superior tightness and insulation,
windows are low E argon and the basement has
under-slab foam insulation. In third party tests, the home
achieved a HERS score of 41 and an EnerGuide score of 84.
FEATURE STORY
21ISSUE 08 | WINTER 2014
TRACY HANES IS A FREELANCE FEATURE WRITER
FOR THE LARGEST DAILY NEWSPAPER IN CANADA
AND SEVERAL MAGAZINES. WWW.TRACYHANES.
This house is rated using the Home Energy Rating System (HERS), property of RESNET of Oceanside, CA.
* Cost of Natural Gas for Space and Hot Water
IECC OBC-12
110 100 90 80 70 60 50 40 30 20 10 0
John Godden October 22, 2013
Built by: Gordon Tobey Developments Ltd.
Address: 296 Goodfellow Rd., Brighton, ON
Rated by: Clearsphere Consulting
Rating Conducted: Oct. 22nd, 2013
41
THIS HOME EXCEEDS THE ONTARIO BUILDING CODE 2012 BY 34%
Hardwood flooring used in the home is FSC
certified. The homeowners like the look of natural
wood and their furniture is a mix of Mission-style
pieces and antique replicas. Materials chosen for
the home, in keeping with the charm of the old
schoolhouse, include stained wood cabinets, oak
flooring, stairs and railings, whitewashed pine
kitchen and dining room ceilings, and a propane
stove designed to look like a traditional wood-
stove. The master ensuite, with all the comforts of a
modern bathroom, has a claw-foot tub reminiscent
of a traditional cast iron tub.
The large kitchen boasts ceiling-height cabinets to
provide plenty of storage and is equipped with a
built-in recycling centre.
Though the fire was an unexpected and unwelcome
event that meant the loss of a beloved heritage
building and their possessions, the homeowners
can now look to their future. Their new house was
completed in October and they are enjoying a space
that was specifically designed to accommodate their
love for entertaining and the day-to-day living needs
of their multi-generational family in warm, comfortable
surroundings - without the costly energy bills.
FEATURE STORY
BUILDER STEVE TOBEY AND PROUD HOMEOWNERS DOUG GOWER AND ALICE ABBOTT
“How much more energy efficient should we build homes?” As a builder one of the most satisfy-
ing feelings is to close a new energy certified home with a buyer who feels that they have received
real value. Value both in terms of their initial investment and their future energy savings. Be-
ing the builder, I specify the extent of energy features installed in the home. Spending Ten to
Twenty Thousand Dollars to save a couple Hundred bucks per year will simply leave your buyer/
potential buyer feeling cold. Achieving long term value in your home is what we do best. Cur-
rently building my own home I want a label that reflects all the energy features that are built in.
My projected as-built HERS score is 37 which is 40% better than code.
Stephen Tobey – Builder
BUILDER NEWS
22
Seeing as custom homebuilder Amedeo Barbini used to play trumpet professionally, it’s tempting to draw on musical
metaphors to describe his approach to house construction. But by orchestrating every aspect from the green core to the
aesthetically pleasing envelope, he is able to create something lasting and beautiful that also appears effortless, like say
something you’d experience at Roy Thompson Hall -- or the Rex Hotel if you’re a jazz enthusiast.
But enough of the musical metaphors. Now into his fourth decade of custom-home building, Barbini begins each home with
intensive research, carefully investigating the mechanics that will produce energy efficiency, excellent interior air quality, and
consistent heat and cooling throughout the entire space. He then designs spaces with views to the exterior in mind, and
pursues the finishes and materials that will result in a distinct aesthetic.
The home he is just completing was purchased at the end of 2012, a sturdy 1950s brick ranch typical of the homes built in
Don Mills, a progressive subdivision development for its day. The neighbourhood’s larger than average lots have made it a
target for more recent renovators and new home builders looking to build larger than average homes. In this case, the 9200
sq. ft. lot allowed for a 5000 sq. ft. home.
Given city bylaw restrictions though, Barbini had to retain 50% of the existing walls, prompting construction of the new
house around the old. This inadvertently served a green purpose – the remaining brick walls provided an additional eight
inches of insulation. Where there isn’t any masonry, walls consist of 2x6 studs with an R value of 22, covered by half-inch
plywood and then two inches of Styrofoam before applying the exterior stucco.
Fortunately, the original footprint was also conducive to the contemporary style Barbini envisioned for the home, by adding
four small “wings” that kept them well within the allowable gross floor area, and adding a second storey that is stepped back
so as not to overpower the lot.
The handsome façade in charcoal grey Belgian brick – chosen for its precision lines and consistent thickness – and clear 1x6
tongue-in-groove Western Cedar slats, has equally attractive guts that have built-in future proofing qualities. The new HVAC
system has been designed to reduce energy use and be a hedge against steadily rising energy costs, but also to create a
consistent and comfortable interior air quality.
The original basement was left untouched structurally – no need for digging down since the ceilings were sufficiently high at
7.5 feet – and all Barbini did was tuck the high velocity ductwork inside the ceiling (that’s the only way you can do it) to make
a clean space without bulkheads. (Note: High velocity ducts are the only ones capable of being tucked inside the ceiling
joists.)
The original basement, which doesn’t extend under the entire new structure, has a built-in energy reducer in the crawlspace
that extends over 1500 sq. ft. At a depth of 30 inches, this crawl space conditions the living space above. If you think about
how cold the floor of a room gets above a garage, no matter how much or what kind of insulation is used, you’ll get the idea.
The crawl space was created with six inches of gravel poured at ground level, then overlaid with an R10 Insultarp insulation
blanket followed by two inches of Roxul and topped in plywood to create a floor should anyone need to get into the crawl
space.
Stepping back the second storey had another design benefit of allowing for some unique light transfer within the home. All
the Glazing area has been placed at the rear of the house to capture the magnificent treed view – with the massive pivoting
glass doors off the main floor living room it feels like being in the Muskoka woods. At the front of the house, Barbini has
placed the bedrooms – a master suite on the main floor and other bedrooms and baths on the second floor. Each bedroom
has wide, short windows positioned close to the ceiling line – these allow plenty of daylight to flood the spaces without
compromising privacy. An overhang at the roof line over each of the smaller windows further filters light, cutting back on
glare and heat and thus going easier on the HVAC – and thermostats. Large windows tend to register higher or lower
temperatures adjacent to the glass, thereby triggering the on and off of air conditioning or heat, leaving the space further
The Best Way to Renovate
INTEGRATING THE PAST, PRESENT AND FUTURE
ALEX NEWMAN
Air.Vapour.Water. Ice
Nothing gets past Henry.
®
Air and Vapour Barrier
Waterproofing Roofing
Protecting properties –
and reputations –
for decades
Henry’s Building Envelope Systems®
provide industry-leading protection
from uncontrolled air, vapour and
moisture, from foundation to roof.
Proven effective in the challenging
winters of Canada, our air and
vapour barriers, waterproofing and
roofing products protect properties
from the elements to save energy,
prevent damage, extend building life,
and create more comfortable and
healthy indoor environments.
BlueskinVP
®
This fully adhered membrane functions not
only as a water-resistant barrier and rain
barrier, but stops uncontrolled air leakage.
performance
longevity
Blueskin
®
WB
Seal out air and moisture, and seal in
energy and comfort with this self-
adhered window and door flashing.
infiltration and water damage
Blueskin
®
WP200
The first choice in sheet applied
waterproofing, this self-adhered
waterproofing membrane is designed
for prepared concrete or masonry
substrates, providing a waterproofing
barrier for below grade use.
lateral water movement
increased protection at overlaps
www.henrycom
Blueskin
®
ROOF
RF200/RF200LT
A self-adhered ice and water
barrier,speciallydesignedfor
slopedroofsurfacestoprovidea
secondaryseal under shingles
or tiles.
temperature underlayment
polyethylene film
fasteners
Eaveguard Self-Adhered
Shingle Underlayment
helps prevent leaks from wind-driven
rain and ice damming.
asphalt and glass fiber mat
slip-resistant working surface
for ease of application
BUILDER NEWS
24
inside the home at the mercy of the fluctuating
temperature levels.
All the windows are manufactured by Inline Fiberglass
Ltd. They are thin-walled fibreglass windows inserted
directly into the walls without exterior moldings or trim,
which makes for a cleaner profile and once caulked a
tighter seal. The fibreglass guarantees maximum heat
retention, losing nothing from the glass to the outdoor
air. Barbini also opted for increased volume with 11-
foot ceilings on the main floor, except for the ten-feet in
the main floor master wing, and nine feet on the second
floor. This increases air- flow and visually expands the
space.
When it came to running the home’s heating and
cooling, Barbini opted for a two zone system – with
two high velocity Airmax air handlers (because of the
home’s large volume and footprint) and a condensing boiler, two copper drain water heat recovery (DWHR) pipes and the
Flowmax indirect hot water tank which acts like a “battery” for the radiant floor system. Domestic hot water comes from
the Flowmax tank, but also stores heat for the radiant floors so that the condensing boiler doesn’t have to cycle on and
off, which is not a good thing. There’s also an energy recovery ventilator for fresh air circulation. This is such serious HVAC
equipment that it’s been divided between two furnace “rooms” -- two air handlers, DWHR pipes, and the Flowmax water
heater in one, and the gas-powered boiler, and orange flex pipes filled with water for the radiant floor heat in the other.
With first and second floors in different zones, in terms of HVAC, Barbini was able to direct more air conditioning to the
second floor.
“Here’s a renovator who believes in the idea of building the value of future proofing into his home, so that on the back end
he can differentiate himself,” says John Godden, with whom Barbini consulted several times about the HVAC system. “It’s
a difficult market, because this is not a
brand new house, so he’s doing all the
things he needs to that makes it better
than the new build. With the extent
he’s gone to he will have a HERS score
below 50. This score is as good as
you can get on new housing without
renewables.”
The system isn’t as complicated as it
sounds, but it does require mechanical
expertise to install. In one of the many
consults Barbini had with Godden
and the Clearsphere team, the one
mechanical contractor whose name
came up repeatedly was Branko
Mijatovic (Alpha Comfort and Control
http://www.alphacomfortcontrol.com/).
“You really need a skilled HVAC
contractor who really understands
this kind of system,” says Godden.
“Especially in a project like this, when
you have different interior ceiling
heights, and you’re aiming to create two
This house is rated using the Home Energy Rating System (HERS), property of RESNET of Oceanside, CA.
* Cost of Natural Gas for Space and Hot Water
IECC OBC-12
110 100 90 80 70 60 50 40 30 20 10 0
John Godden November 27, 2013
Built by: Amedeo Barbini
Address: 61 Talwood DR, Toronto, ON
Rated by: Clearsphere Consulting
Rating Conducted: Nov. 27th , 2013
49
THIS HOME EXCEEDS THE ONTARIO BUILDING CODE 2012 BY 26%
WINDOW DESIGN MAXIMIZES NATURAL LIGHT AND PRIVACY
ISSUE 07 | FALL 2013
different zones in order to future proof against rising
energy costs. It’s important to have a very good mechanical
contractor, who can match equipment to the needs of each
individual home.”
Also located in the second furnace area are the sump pump
and the sewage pump. Because North York is lower than the
city’s drains by a foot, every house in the area has a sump
pump and a sewage pump for better drainage. The sewage
pump takes the drain water from the laundry room and base-
ment bathroom, while water from the rest of the house is car-
ried away by the stack.
Honeywell contributed state of the art controllable thermostats
to the house. This central control manages, heating, cooling
as well as humidification
and central ventilation through a energy recovery ERV. The
ERV manages both, humidity in summer and winter, but these
are not your usual control panels. Wi-Fi compatible, the controls
can be carried remotely into any room in the house so that
temperatures can be controlled from anywhere. If the bedroom
is too cool, and you only want to raise the temperature there,
you can take the remote and increase the heat in that room
only, Barbini explains. “This isn’t only about being able to
control the environment for comfort,” he says, “but also about
economics. No sense wasting heat in areas you are not using.”
The new home, which Barbini expects to market in the
spring, is a good example of an integrated design process.
That is, in simplest terms,
integrating the design of a beautiful home with the
design of its beautiful mechanics, which results in space that
is aesthetically pleasing, and comfortable. These future proofing
efforts will pay off for the new owners of his home in much
lower gas and electricity bills.
Barbini goes to such lengths with materials,
finishes and systems because he wants his houses to last, to
be gentle on the environment, and to garner lower heating and
cooling bills. Most builders will only go to such lengths when
already working for a client with imagination and deep pockets,
but Barbini is prepared to gamble that the end user – in this
case the buyer of this modern Don Mills home – will recognize
its hidden, as well as overt qualities.
BUILDER NEWS
ALEX NEWMAN IS A WRITER, EDITOR AND RESEARCHER AT
WWW.INTEGRITYCOMMUNICATIONS.CA
ISSUE 08 | WINTER 2014 25
ALSOAVAILABLE
INR9&R11
Introducing Amdry, the only insulated
channels.
C
onnecter System
BUILDER NEWS
The Best Way to
Insulate Basement
Floors
When it comes to reducing energy consumption within the
home there are many factors to consider; the most critical
of which is insulation. Creating a tight and efficient envelope
begins with the systems and products builders use, and given
the recent changes to the Ontario Building code, insulation and
its importance to the homeowner has never been as significant
a topic.
Amvic Building system, a Canadian based insulation manufacturer,
has once again raised the bar with its two most recent products;
the Silverboard SB35-UC board and PEX Radiant Heat Insulating
Panels. Updates to the SB12 building code now mandate that
all concrete slabs containing radiant heat piping must have a
minimum R10 insulation under the slab; the SB35-UC not only
meets this requirement, but also provides vapour, radiant and
radon barriers. Silverboard SB35-UC was specifically designed
for on or below grade insulation applications. It also offers a
flexibility (84 Psi) and load compression toughness (35 Psi) not
found in traditional flat-sheet EPS or fibreglass boards, which
not only increases job-site efficiency by enabling workers to
walk and drive over it, but also minimizes waste.
Peter Voong, of Castle Form Homes, says the Silverboard SB35-
UC is an unparalleled product, “When it comes to insulating
radiant floor heating - the most efficient method for heating your
house - this product is the superior choice for insulation.” In his
most recent LEED build Voong used the SB35-UC under the
basement slab and walkout, “It was really easy to install...simple
and light-weight, a very cost-effective and versatile product.”
The reflective laminated surfaces not only reflect radiant energy
(keeping heat outdoors during the summer and containing it
inside during the winter), it also provides a continual barrier
that protects the core from air and moisture for longer life.
Silverboard SB35-UC is available in 4’x8’ sections and can be
found at a variety of hardware and home building stores.
The Insulated Radiant PEX panel is another Amvic product
that strives to improve upon installation and performance
characteristics for Hydronic radiant floor heating systems.
While Silverboard is attached to a mesh screen that sits on the
piping, PEX panels were designed to create non-contact voids.
The combination of expanded polystyrene (EPS) insulation, one
of the highest performing, energy efficient insulation materials
available today, vacuum moulded to a high impact reinforcing
HOWARD COHEN AND
BETTER BUILDER STAFF
26
BUILDER NEWS
27
and VB polystyrene film makes for a strong resilient interlocking PEX panel. The reverse tapered, raised nubs form a
“mushroom” shape to lock the PEX piping firmly in place once installed - also allowing the panel to accept 3/8” to 1” pipe
diameters (more than any other panel on the market). The PEX piping is easily inserted into the panel simply by walking on
the tube. Once inserted the pipe will be properly positioned and seated on the panel. The innovative patented design ensures
that the tube will be completely surrounded by concrete and not resting on the bottom face of the panel as some competitive
products do. This allows for the proper heat distribution of the radiant tubing and more efficient energy transfer.
ISSUE 08 | WINTER 2014
HOWARD COHEN, DIVERSIFIED INSULATION PRODUCTS MANAGER, AMVIC
HOWARD COHEN, DIVERSIFIED INSULATION PRODUCTS MANAGER, AMVIC
2 INCH SILVERBOARD R10 INSULATION PLUS A RADIANT BARRIER - THE BEST WAY TO INSULATE
BUILDER NEWS
28
Doug Tarry Homes recently opened our latest model home,
the Edenbrook, during the first week of October. Today, as
an industry, builders open new model home centres all the
time, and while we are always proud to show off our newest
creations, there are the rare exceptions when something
truly revolutionary is presented to the marketplace.
Such is the case with this Discovery Home built as part of
our commitment to the Union Gas Optimum Home Program.
Through the Optimum Home Program, we have been able to
work closely with a number of building science experts and
consultants to help us address some critical next steps in the
construction of high-performance homes. In this particular
home we are demonstrating two new technological features
that will have a significant impact on the building code and
how homes are built in the future.
The first is the pilot project we are conducting with Dettson
Industries on right sized furnaces. The F280 guidelines,
that mechanical designers use to size their equipment,
do not properly account for the tighter homes that the
current Ontario Building Code and energy programs such
as Energy Star are requiring of builders. This, combined
with furnace manufacturers not recognizing the need for
smaller HVAC equipment, is leading to performance issues
in our homes. Issues such as temperature differences and
comfort complaints.
An updated F280 will be an alternative option under the
new 2012 OBC, starting in January. Using the new F280
will see furnace size requirements drop significantly. Doug
Tarry Homes has been working on this sizing issue for
several years. What we have found is that under the old
F280 a furnace might be sized at 45,000 or even 60,000
BTU's of heat output, but might only need to be 28-30,000
BTU's on the coldest day of the year. The challenge with the
new sizing requirements that we should be using is that
there are no furnaces available that perform between
12-30,000 BTU's, which is what we need. Regrettably
manufacturers seem to be fairly ambivalent to our needs.
This is where Dettson Industries comes into the picture.
This Canadian owned furnace manufacturer, based in
Quebec, has recognized that there is a need for right
sized furnaces. I was put in touch with Marc Chenier from
Dettson through our involvement in the Union Gas
Optimum Home Program. Back in March I had the
opportunity to visit the test lab near Montreal and check
out the product they were planning to manufacture.
What I was most impressed about was not only the
willingness of the Dettson engineers to listen to our
performance concerns but that they understood the need
for smaller, right sized, high performance furnaces. After
some very positive conversations we agreed to provide
Dettson industries with two homes to test their right sized
furnaces in.
On October 3rd we had the privilege of unveiling the new
Dettson Chinook prototype furnace. The Chinook is fully
modulating with an ECM motor and has a BTU output
range between 12,000 to 30,000 BTU's, which matches
our homes needs. It is currently available for viewing in
our Discovery Home in St. Thomas, where we are testing
the prototype over the next twelve months. Dettson
is projecting that the BTU Chinook will be available in the
market by February. Builders who are constructing MURBS
will be interested to know that Dettson is also working on
a 15,000 BTU furnace they hope to bring to market in the
spring.
Of course none of the right sizing of furnaces project
would have been possible without the understanding and
support of our former Chief Building Official, Leon Bach,
who understands the performance issues and permitted
us to design the system to the new F280 Standard as
an alternative compliance solution even though the new
Standard does not become an option until January 2014.
We are very appreciative of Leon’s support and the other
building officials involved with our Discovery Home that
helped to make this project a reality.
The other pilot project featured in our Discovery Home is
a new basement wall system that we call the Optimum
Basement Wall. I've previously written about our journey to
a better basement wall and our work with ROXUL. My next
article will focus on the Optimum Basement Wall.
DOUG TARRY
DOUG TARRY JR., IS THE DIRECTOR OF MARKETING AT
DOUG TARRY HOMES IN ST. THOMAS , ONTARIO.
The Best New Demo Project
THE OPTIMUM HOME WITH THE OPTIMIZED HVAC SYSTEM
BUILDER NEWS
ELECTRICAL DATA
WEIGHT 75K 105K 120K
lb / kg 114 / 51,7 138 / 62,6 146 / 66,2
Supply 115 Volts - 60 Hertz - 1 Phase
Maximum consumption From 10,53 to 16,19 Amps
40 VA
www.dettson.ca
WARM AIR GAS FURNACE DESIGNED,
ENGINEERED, AND MANUFACTURED IN
CANADA FOR HEATING AND
COOLING CANADIAN RESIDENCES
Benefits and differentiators
Product line features
- Single stage
Product release schedule
Phase I -
Phase II -
Phase III -
15 K 34,29 31,75 31,75 33,02 x 60,96
30 K 34,29 31,75 31,75 33,02 x 60,96
45 K 34,29 31,75 31,75 33,02 x 60,96
60 K 40 37,46 36,83 38,1 x 60,96
75 K 40 37,46 36,83 38,1 x 60,96
105 K 53,34 50,80 41,91 43,18 x 60,96
120 K 53,34 50,80 41,91 43,18 x 60,96
15 k 13 1/2 12 1/2 12 1/2 13 x 24
30 k 13 1/2 12 1/2 12 1/2 13 x 24
45 k 13 1/2 12 1/2 12 1/2 13 x 24
60 k 15 3/4 14 3/4 14 1/2 15 x 24
75 k 15 3/4 14 3/4 14 1/2 15 x 24
105 k 21 20 16 1/2 17 x 24
120 k 21 20 16 1/2 17 x 24
DIMENSIONS (inches)
DIMENSIONS ( )
Furnace
size
Filter Size
A
Cabinet
width
B
Supply
duct width
C
Return
duct width
Furnace
size
Filter Size
A
Cabinet
width
B
Supply
duct width
C
Return
duct width
19.08 8.54
0
2.50
5.03
B
Supply duct
width
A
15.71
33.57
6.76
29,02
24,00
1.09
1.03
6.05
2.66
2.26
0
0.88
2.00
C
Returnductheight
Return duct width
BUILDER NEWS
BP Excel breaks new ground
in structural insulation
thanks to a membrane that
combines air barrier protec-
tion, moisture-evacuating
breathability, and strength
like no other product.
And it’s green — made from
98% recycled materials, free
of VOCs and ozone-depleting
CFCs or HCFCs, and glued
together with wheat starch.
For homebuilders looking
for innovation and value
on an exponential scale:
Excel is innovative green
design, exceptional thermal
insulation and structural
strength all in one breathable
sheathing that delivers
outstanding performance
with unparalleled strength.
www.bpcan.com
WELCOME TO STRUCTURAL INSULATION
REINVENTED FOR TODAY’S WORLD —
AND A SUSTAINABLE TOMORROW.
MADE HERE PREFERRED EVERYWHERE
NEW!
31
BUILDER NEWS
Reliable,
customized,
maRtinoHeating • air conditioning • indoor air Quality • HVac design
1-800-465-5700
™
www.martinohvac.com
The ARGILE Project:
BUILDING SCIENCE RESEARCH AT GEORGE BROWN COLLEGE
ARGILE'S vision is to research and develop optimal systems of materials and methods for the retrofitting of existing
vintage solid masonry buildings, with the objectives of improving their energy efficiency, durability and occupant health.
The International Energy Agency emphasizes the need for better building practices by stating "... existing buildings are
responsible for over 40% of the world's total primary energy consumption" (IEA, 2008). It has thus become clear to our
research team that increasing the energy efficiency of buildings is a vital step we must take to ensure energy security and
environmental damage is minimized for our future generations. Although the aim to investigate the cost/benefit of retrofitting
vintage buildings and to establish a link between vintage building retrofits and "sustainability" represents the main
focus of ARGILE, there is a need for advanced contractors to push the envelope, set new standards, and surpass the
THE ARGILE RESEARCH TEAM
ISSUE 08 | WINTER 2014
BUILDER NEWS
32
requirements of the Ontario Building Code
for new construction in homes.
The "Optimum Basement Wall" designed by
Doug Tarry Custom Homes Ltd. functions
to mitigate condensation build up within the
basement wall assembly. According to Doug
Tarry Jr.: "Consumers today expect their
basements to be as usable as their above
grade floor space, but the conditions are
completely different. We realized that the
current building code is leading to far too
many basements with mould and moisture
issues. The problem is the vapour diffusion in the wall. Clients don't understand that this vapour flow is a natural occurrence
and that most basements will have issues with vapour flow that will frequently lead to mould."
The ARGILE research team has partnered with industry leader, ROXUL® and progressive contractor, Doug Tarry Custom
Homes Ltd. to study their show home in St. Thomas, ON. Our research aims to verify the field performance of their
basement insulation system by utilizing innovative technology to remotely collect data for evaluation. The wall system
features the use of CertainTeed's "MemBrain", which replaces the top third of the polyethelyene sheeting used in the
assembly. This polyamide-based material has the ability to adapt it's permeability with changing climatic conditions.
As relative humidity increases, it's water vapor
permeability increases, and during low humidity
conditions, it's permeability will decrease to
resist water vapor permeability. This provides
the potential to dry out condensation that would
normally collect behind the polyethylene and
lead to mould growth. The use of the ROXUL®
Comfortboard IS layer is also critical. Since stone
wool is water repellent, it will allow any liquid
water that may enter into the assembly to drain
down its surface to the footing instead of being
wicked into the insulation.
ARGILE Research's in-house team has
developed temperature, moisture content, and
relative humidity sensors which have been
installed at critical points within the wall assembly,
as well as in the below grade soil. The data
logging systems have been programmed to
translate data remotely for analysis. The
information captured by the system will be
analyzed for a full heating and cooling cycle to
assess the durability and performance of the
“Optimum Basement Wall”.
THE ARGILE RESEARCH TEAM: P. CHRISTOPHER TIMUSK (PRINCIPAL INVESTIGATOR) | STEFFANIE ADAMS (CO-INVESTIGATOR) | ANDREW FRASER (CO-INVESTIGATOR)
ALEXIS RODZIEWICZ (PROJECT MANAGER) | ARIZONA DIXON (STUDENT RESEARCHER)
OPTIMUM BASEMENT WALL - MONITORING ROXUL PERFORMANCE
MARC BUCKLEY - RESEARCH WITH GEORGE BROWN
ISSUE 07 | FALL 2013
BUILDER NEWS
33
]
Solar Ready
It’s fitting that this edition is dedicated to future proofing. This is a concept that
I have been discussing and designing into my homes for many years. Why? Be-
cause I believe that rising energy costs over the next generation will continue
to make energy efficiency a greater priority for our consumers. As an industry,
we continue to build ever more energy efficient homes. However, there is one
major challenge that we face: our customers!
Don’t get me wrong, I am grateful for all of my customers and I hope to build
for many more. It’s just that today’s consumer is much more demanding than
even a few years ago. They want longer showers with multiple showerheads
just like they see on the TV shows; they want their home to be uniformly cool
all summer, even with that big bank of windows facing the sun. The expecta-
tion of performance is that their utility bill will go down, or at least not change,
even though they continue to use their personal car wash (that’s what I call the
full body wash shower) and run that AC right through the day.
At some point in our customers’ future their thoughts will change from conserva-
tion to generation. That’s where future proofing comes in. So I thought I’d share
my insights on Solar Ready, the ultimate future proofing for the homes we build.
In 2007, Doug Tarry Homes was contracted by Natural Resources Canada to conduct the Solar Ready pilot project.
This included writing the first Solar Ready technical specifications. Since 2007, we have
continued to build all of our homes with Solar Ready design as a standard feature. In that time we have also installed
several solar thermal water heating systems. In October 2012, NRCan published the revised Solar Ready Specifica-
tions.
So here’s the good news. Solar Ready is fairly easy and inexpensive to include in a home provided you put some
thought into it during the design process. OK, so two storey homes can be a bit harder because of the popularity of
open concept main floors even on two storey homes. It has been our experience that it costs an additional $350-$450
per home for the Solar Ready rough in.
SO WHAT IS A SOLAR READY HOME?
There are two key components. First, space on the roof at a viable solar angle, and second, a conduit from mechanical
room to accessible attic space. Roof orientation for solar installations is considered viable from Southeast around to
West for solar thermal systems. South is most efficient for Photo Voltaic systems. Here are some important points to
remember:
•	The solar conduit needs to run from the mechanical room to the attic. I prefer to install two – 2” conduits, rather than one 4”.
If you ever have to bend the conduit slightly, there is no give in the 4”. Also the 4” requires a 2x6 wall which may not be
otherwise necessary for the home.
•	It is important to avoid plumbing or mechanical runs in the dedicated location of the conduit, or it may be almost impos-
sible to find later on. Whatever conduit type you choose, it is important that they be capped at both the top and bot-
tom, otherwise you can have a condensation loop into your attic as well as a fire chase. I don’t trust tape as the glue
will diminish over time.
•	Location of the future solar hot water tank should be shown on the basement plan so that the appropriate amount of space
is available. It is also good practice to show the roof elevation that the panels are intended to be installed on, so that there
•	It is not a requirement, but it is a
recommended best practice that the
trusses intended to carry the solar
panels be designed and built with an
additional 5 lb. dead load to account
for the additional weight.
•	Installation of panels should not be
directly into the top chord of the truss.
Rather it is better practice to attach
scab lumber to the side of the top
chord and attach into the scab.
•	The existing Domestic Hot Water
Heater needs to have plumbing valves
and “T”s installed and an electrical
outlet needs to be located beside the
unit. This is to permit quick connection
at the time of installation.
Fire
Resistant
Water
Repellent
Sound
Absorbent
Saves
Energy
Made
from Stone
Recycled
Content
TM
HIGH
R
ECYCLED CO
N
TENT
*Contact us for details.
HIGH
R
ECYCLED CO
N
TENT
R
E
C Y C L A B L
E*
Achieving an R-20 Basement Wall “IS” Easy
with Roxul ComfortBoard™
IS.
■ Prevent Thermal Bridging: Installing ComfortBoard™
IS against the foundation wall
before you frame the studs provides for a continual layer of thermal protection.
■ Non Combustible: Provides for combined thermal and fire-resistant properties.
■ High Recycled Content: Made from natural stone and up to 93% recycled material.
INTERIOR BASEMENT WALL APPLICATION BY ROXUL®
www.roxul.com
ComfortBoard™ IS is a trademark of Roxul Inc.
GREENGUARD®
is a registered trademark of Greenguard Environmental Institute.
ROX-2410_0712
BUILDER NEWS
34
PAGE TITLE
Features
To learn more, visit
www.savingsbydesign.ca
TM
Helping builders design and build
more energy efficient homes.
New building codes require new approaches to housing
design and energy performance. Enbridge’s Savings
by Design program is here to help. The program offers
free access to design and technical experts, as well
as valuable incentives to help design and build more
energy efficient homes.
Using our unique and collaborative Integrated Design
Process (IDP), we will work with you to identify optimal
solutions for improving energy efficiency 25% beyond
Ontario Building Code 2012.

Más contenido relacionado

La actualidad más candente

Better Builder Magazine
Better Builder MagazineBetter Builder Magazine
Better Builder MagazineBetter Builder
 
LmP House Final
LmP House FinalLmP House Final
LmP House FinalLaura Dawe
 
Better Builder, Issue 16, Winter-2015
Better Builder, Issue 16, Winter-2015Better Builder, Issue 16, Winter-2015
Better Builder, Issue 16, Winter-2015Better Builder
 
Better Builder, Issue 14, Summer 2015
Better Builder, Issue 14, Summer 2015Better Builder, Issue 14, Summer 2015
Better Builder, Issue 14, Summer 2015Better Builder
 
Better Builder, Issue 13, Spring 2015
Better Builder, Issue 13, Spring 2015Better Builder, Issue 13, Spring 2015
Better Builder, Issue 13, Spring 2015Better Builder
 
housing nigeria1
housing nigeria1housing nigeria1
housing nigeria1yann lucas
 
Code Compliance for Advanced Homes – Meeting Code with Fewer Gizmos
Code Compliance for Advanced Homes – Meeting Code with Fewer GizmosCode Compliance for Advanced Homes – Meeting Code with Fewer Gizmos
Code Compliance for Advanced Homes – Meeting Code with Fewer GizmosToronto 2030 District
 
GBF2007 - NowHouse - Lorraine Gaultier
GBF2007 - NowHouse - Lorraine GaultierGBF2007 - NowHouse - Lorraine Gaultier
GBF2007 - NowHouse - Lorraine GaultierToronto 2030 District
 
Greening the Energy Retrofit
Greening the Energy RetrofitGreening the Energy Retrofit
Greening the Energy RetrofitERH West
 
High Performance Design in Oregon, Two Regional Case Studies
High Performance Design in Oregon, Two Regional Case StudiesHigh Performance Design in Oregon, Two Regional Case Studies
High Performance Design in Oregon, Two Regional Case Studiesenergytrustor
 
Minneapolis Passive House and Zero Energy Ready Home Report Presentation
Minneapolis Passive House and Zero Energy Ready Home Report PresentationMinneapolis Passive House and Zero Energy Ready Home Report Presentation
Minneapolis Passive House and Zero Energy Ready Home Report PresentationTE Studio
 
Better Builder Magazine, Fall 2013
Better Builder Magazine, Fall 2013Better Builder Magazine, Fall 2013
Better Builder Magazine, Fall 2013Better Builder
 
Better Builder, Issue 15, Fall-2015
Better Builder, Issue 15, Fall-2015Better Builder, Issue 15, Fall-2015
Better Builder, Issue 15, Fall-2015Better Builder
 
High performance green building marketing brochure 3 20-08
High performance green building marketing brochure 3 20-08High performance green building marketing brochure 3 20-08
High performance green building marketing brochure 3 20-08crossbridgeinc
 
My EE Home - Ravi Teja Pabbisetty (NDTV)
My EE Home - Ravi Teja Pabbisetty (NDTV) My EE Home - Ravi Teja Pabbisetty (NDTV)
My EE Home - Ravi Teja Pabbisetty (NDTV) Ravi Teja Pabbisetty
 
Leed rating system with case study
Leed rating system with case studyLeed rating system with case study
Leed rating system with case studyInu shakya
 
R&M Developments & Property Group Ltd - offsite history elements 2018 full co...
R&M Developments & Property Group Ltd - offsite history elements 2018 full co...R&M Developments & Property Group Ltd - offsite history elements 2018 full co...
R&M Developments & Property Group Ltd - offsite history elements 2018 full co...Thomas McKenna
 

La actualidad más candente (20)

Better Builder Magazine
Better Builder MagazineBetter Builder Magazine
Better Builder Magazine
 
LmP House Final
LmP House FinalLmP House Final
LmP House Final
 
Better Builder, Issue 16, Winter-2015
Better Builder, Issue 16, Winter-2015Better Builder, Issue 16, Winter-2015
Better Builder, Issue 16, Winter-2015
 
Better Builder, Issue 14, Summer 2015
Better Builder, Issue 14, Summer 2015Better Builder, Issue 14, Summer 2015
Better Builder, Issue 14, Summer 2015
 
Better Builder, Issue 13, Spring 2015
Better Builder, Issue 13, Spring 2015Better Builder, Issue 13, Spring 2015
Better Builder, Issue 13, Spring 2015
 
housing nigeria1
housing nigeria1housing nigeria1
housing nigeria1
 
Code Compliance for Advanced Homes – Meeting Code with Fewer Gizmos
Code Compliance for Advanced Homes – Meeting Code with Fewer GizmosCode Compliance for Advanced Homes – Meeting Code with Fewer Gizmos
Code Compliance for Advanced Homes – Meeting Code with Fewer Gizmos
 
GBF2007 - NowHouse - Lorraine Gaultier
GBF2007 - NowHouse - Lorraine GaultierGBF2007 - NowHouse - Lorraine Gaultier
GBF2007 - NowHouse - Lorraine Gaultier
 
Greening the Energy Retrofit
Greening the Energy RetrofitGreening the Energy Retrofit
Greening the Energy Retrofit
 
High Performance Design in Oregon, Two Regional Case Studies
High Performance Design in Oregon, Two Regional Case StudiesHigh Performance Design in Oregon, Two Regional Case Studies
High Performance Design in Oregon, Two Regional Case Studies
 
Minneapolis Passive House and Zero Energy Ready Home Report Presentation
Minneapolis Passive House and Zero Energy Ready Home Report PresentationMinneapolis Passive House and Zero Energy Ready Home Report Presentation
Minneapolis Passive House and Zero Energy Ready Home Report Presentation
 
Better Builder Magazine, Fall 2013
Better Builder Magazine, Fall 2013Better Builder Magazine, Fall 2013
Better Builder Magazine, Fall 2013
 
Better Builder, Issue 15, Fall-2015
Better Builder, Issue 15, Fall-2015Better Builder, Issue 15, Fall-2015
Better Builder, Issue 15, Fall-2015
 
High performance green building marketing brochure 3 20-08
High performance green building marketing brochure 3 20-08High performance green building marketing brochure 3 20-08
High performance green building marketing brochure 3 20-08
 
My EE Home - Ravi Teja Pabbisetty (NDTV)
My EE Home - Ravi Teja Pabbisetty (NDTV) My EE Home - Ravi Teja Pabbisetty (NDTV)
My EE Home - Ravi Teja Pabbisetty (NDTV)
 
Leed rating system with case study
Leed rating system with case studyLeed rating system with case study
Leed rating system with case study
 
R&M Developments & Property Group Ltd - offsite history elements 2018 full co...
R&M Developments & Property Group Ltd - offsite history elements 2018 full co...R&M Developments & Property Group Ltd - offsite history elements 2018 full co...
R&M Developments & Property Group Ltd - offsite history elements 2018 full co...
 
Leed
Leed Leed
Leed
 
Gtower report
Gtower reportGtower report
Gtower report
 
Better Builder Issue 7
Better Builder Issue 7Better Builder Issue 7
Better Builder Issue 7
 

Similar a Better Builder Issue 8

Better Builder Magazine, Issue 06 / Summer 2013
Better Builder Magazine, Issue 06 / Summer 2013Better Builder Magazine, Issue 06 / Summer 2013
Better Builder Magazine, Issue 06 / Summer 2013Better Builder Magazine
 
Better Builder Magazine, Issue 16 / Winter 2015
Better Builder Magazine, Issue 16 / Winter 2015Better Builder Magazine, Issue 16 / Winter 2015
Better Builder Magazine, Issue 16 / Winter 2015Better Builder Magazine
 
Better Builder Magazine, Issue 11 / Fall 2014
Better Builder Magazine, Issue 11 / Fall 2014Better Builder Magazine, Issue 11 / Fall 2014
Better Builder Magazine, Issue 11 / Fall 2014Better Builder Magazine
 
Better Builder Magazine, Issue 18 / Summer 2016
Better Builder Magazine, Issue 18 / Summer 2016Better Builder Magazine, Issue 18 / Summer 2016
Better Builder Magazine, Issue 18 / Summer 2016Better Builder Magazine
 
Better Builder Magazine, Issue 07 / Fall 2013
Better Builder Magazine, Issue 07 / Fall 2013Better Builder Magazine, Issue 07 / Fall 2013
Better Builder Magazine, Issue 07 / Fall 2013Better Builder Magazine
 
Better Builder Magazine, Issue 19 / Fall 2016
Better Builder Magazine, Issue 19 / Fall 2016Better Builder Magazine, Issue 19 / Fall 2016
Better Builder Magazine, Issue 19 / Fall 2016Better Builder Magazine
 
Better Builder Magazine, Spring Issue, 2014
Better Builder Magazine, Spring Issue, 2014Better Builder Magazine, Spring Issue, 2014
Better Builder Magazine, Spring Issue, 2014Better Builder
 
Better Builder Magazine, Issue 09 / Spring 2014
Better Builder Magazine, Issue 09 / Spring 2014Better Builder Magazine, Issue 09 / Spring 2014
Better Builder Magazine, Issue 09 / Spring 2014Better Builder Magazine
 
Better Builder Magazine, Issue 13 / Spring 2015
Better Builder Magazine, Issue 13 / Spring 2015Better Builder Magazine, Issue 13 / Spring 2015
Better Builder Magazine, Issue 13 / Spring 2015Better Builder Magazine
 
Better Builder Magazine, Issue 20 / Winter 2016
Better Builder Magazine, Issue 20 / Winter 2016Better Builder Magazine, Issue 20 / Winter 2016
Better Builder Magazine, Issue 20 / Winter 2016Better Builder Magazine
 
Better Builder Magazine Issue 20 Winter 2016
Better Builder Magazine Issue 20 Winter 2016Better Builder Magazine Issue 20 Winter 2016
Better Builder Magazine Issue 20 Winter 2016Better Builder
 
Better Builder Magazine, Issue 43 / Autumn 2022
Better Builder Magazine, Issue 43 / Autumn 2022Better Builder Magazine, Issue 43 / Autumn 2022
Better Builder Magazine, Issue 43 / Autumn 2022Better Builder Magazine
 
Better Builder Magazine, Issue 22 / Summer 2017
Better Builder Magazine, Issue 22 / Summer 2017Better Builder Magazine, Issue 22 / Summer 2017
Better Builder Magazine, Issue 22 / Summer 2017Better Builder Magazine
 
Better Builder Magazine, Issue 39 / Autumn 2021
Better Builder Magazine, Issue 39 / Autumn 2021Better Builder Magazine, Issue 39 / Autumn 2021
Better Builder Magazine, Issue 39 / Autumn 2021Better Builder Magazine
 
Better Builder Magazine, Issue 44 / Winter 2022
Better Builder Magazine, Issue 44 / Winter 2022Better Builder Magazine, Issue 44 / Winter 2022
Better Builder Magazine, Issue 44 / Winter 2022Better Builder Magazine
 
Better Builder Magazine, Issue 35 / Autumn 2020
Better Builder Magazine, Issue 35 / Autumn 2020Better Builder Magazine, Issue 35 / Autumn 2020
Better Builder Magazine, Issue 35 / Autumn 2020Better Builder Magazine
 
Better Builder Magazine, Issue 27 / Fall 2018
Better Builder Magazine, Issue 27 / Fall 2018Better Builder Magazine, Issue 27 / Fall 2018
Better Builder Magazine, Issue 27 / Fall 2018Better Builder Magazine
 
Better Builder Magazine, Issue 01 / Spring 2012
Better Builder Magazine, Issue 01 / Spring 2012Better Builder Magazine, Issue 01 / Spring 2012
Better Builder Magazine, Issue 01 / Spring 2012Better Builder Magazine
 

Similar a Better Builder Issue 8 (20)

Better Builder Magazine, Issue 06 / Summer 2013
Better Builder Magazine, Issue 06 / Summer 2013Better Builder Magazine, Issue 06 / Summer 2013
Better Builder Magazine, Issue 06 / Summer 2013
 
Better Builder Magazine, Issue 16 / Winter 2015
Better Builder Magazine, Issue 16 / Winter 2015Better Builder Magazine, Issue 16 / Winter 2015
Better Builder Magazine, Issue 16 / Winter 2015
 
Better Builder Magazine, Issue 11 / Fall 2014
Better Builder Magazine, Issue 11 / Fall 2014Better Builder Magazine, Issue 11 / Fall 2014
Better Builder Magazine, Issue 11 / Fall 2014
 
Better Builder Magazine, Issue 18 / Summer 2016
Better Builder Magazine, Issue 18 / Summer 2016Better Builder Magazine, Issue 18 / Summer 2016
Better Builder Magazine, Issue 18 / Summer 2016
 
Better Builder Magazine, Issue 07 / Fall 2013
Better Builder Magazine, Issue 07 / Fall 2013Better Builder Magazine, Issue 07 / Fall 2013
Better Builder Magazine, Issue 07 / Fall 2013
 
Better Builder Magazine, Issue 19 / Fall 2016
Better Builder Magazine, Issue 19 / Fall 2016Better Builder Magazine, Issue 19 / Fall 2016
Better Builder Magazine, Issue 19 / Fall 2016
 
Better Builder Issue 9
Better Builder Issue 9Better Builder Issue 9
Better Builder Issue 9
 
Better Builder Magazine, Spring Issue, 2014
Better Builder Magazine, Spring Issue, 2014Better Builder Magazine, Spring Issue, 2014
Better Builder Magazine, Spring Issue, 2014
 
Better Builder Magazine, Issue 09 / Spring 2014
Better Builder Magazine, Issue 09 / Spring 2014Better Builder Magazine, Issue 09 / Spring 2014
Better Builder Magazine, Issue 09 / Spring 2014
 
Better Builder Magazine, Issue 13 / Spring 2015
Better Builder Magazine, Issue 13 / Spring 2015Better Builder Magazine, Issue 13 / Spring 2015
Better Builder Magazine, Issue 13 / Spring 2015
 
Better Builder Magazine, Issue 20 / Winter 2016
Better Builder Magazine, Issue 20 / Winter 2016Better Builder Magazine, Issue 20 / Winter 2016
Better Builder Magazine, Issue 20 / Winter 2016
 
Better Builder Magazine Issue 20 Winter 2016
Better Builder Magazine Issue 20 Winter 2016Better Builder Magazine Issue 20 Winter 2016
Better Builder Magazine Issue 20 Winter 2016
 
Better Builder Magazine, Issue 43 / Autumn 2022
Better Builder Magazine, Issue 43 / Autumn 2022Better Builder Magazine, Issue 43 / Autumn 2022
Better Builder Magazine, Issue 43 / Autumn 2022
 
Better Builder Magazine, Issue 22 / Summer 2017
Better Builder Magazine, Issue 22 / Summer 2017Better Builder Magazine, Issue 22 / Summer 2017
Better Builder Magazine, Issue 22 / Summer 2017
 
Better Builder Magazine, Issue 39 / Autumn 2021
Better Builder Magazine, Issue 39 / Autumn 2021Better Builder Magazine, Issue 39 / Autumn 2021
Better Builder Magazine, Issue 39 / Autumn 2021
 
Better Builder Magazine, Issue 44 / Winter 2022
Better Builder Magazine, Issue 44 / Winter 2022Better Builder Magazine, Issue 44 / Winter 2022
Better Builder Magazine, Issue 44 / Winter 2022
 
Better Builder Magazine, Issue 35 / Autumn 2020
Better Builder Magazine, Issue 35 / Autumn 2020Better Builder Magazine, Issue 35 / Autumn 2020
Better Builder Magazine, Issue 35 / Autumn 2020
 
Better Builder Magazine, Issue 27 / Fall 2018
Better Builder Magazine, Issue 27 / Fall 2018Better Builder Magazine, Issue 27 / Fall 2018
Better Builder Magazine, Issue 27 / Fall 2018
 
Better Builder Magazine, Issue 01 / Spring 2012
Better Builder Magazine, Issue 01 / Spring 2012Better Builder Magazine, Issue 01 / Spring 2012
Better Builder Magazine, Issue 01 / Spring 2012
 
Better Builder Issue One
Better Builder Issue OneBetter Builder Issue One
Better Builder Issue One
 

Más de Anna-Marie McDonald

What's On at the Pickering Public Library June - August 2014
What's On at the Pickering Public Library June - August 2014What's On at the Pickering Public Library June - August 2014
What's On at the Pickering Public Library June - August 2014Anna-Marie McDonald
 
What's On at the Pickering Public Library in July & August 2013? Tonnes!
What's On at the Pickering Public Library in July & August 2013? Tonnes!What's On at the Pickering Public Library in July & August 2013? Tonnes!
What's On at the Pickering Public Library in July & August 2013? Tonnes!Anna-Marie McDonald
 
Whats On at the Pickering Public Library for Sept - Dec 2012
Whats On at the Pickering Public Library for Sept - Dec 2012Whats On at the Pickering Public Library for Sept - Dec 2012
Whats On at the Pickering Public Library for Sept - Dec 2012Anna-Marie McDonald
 
Pickering Public Library - What's On for Summer 2012
Pickering Public Library - What's On for Summer 2012Pickering Public Library - What's On for Summer 2012
Pickering Public Library - What's On for Summer 2012Anna-Marie McDonald
 
What's ON @ your library Jan - April 2012
What's ON @ your library Jan - April 2012What's ON @ your library Jan - April 2012
What's ON @ your library Jan - April 2012Anna-Marie McDonald
 
Pickering Public Library - Living Library Event
Pickering Public Library - Living Library EventPickering Public Library - Living Library Event
Pickering Public Library - Living Library EventAnna-Marie McDonald
 

Más de Anna-Marie McDonald (12)

Better Builder Issue 3
Better Builder Issue 3Better Builder Issue 3
Better Builder Issue 3
 
Better Builder Issue 2
Better Builder Issue 2Better Builder Issue 2
Better Builder Issue 2
 
What's On at the Pickering Public Library June - August 2014
What's On at the Pickering Public Library June - August 2014What's On at the Pickering Public Library June - August 2014
What's On at the Pickering Public Library June - August 2014
 
What's On at the Pickering Public Library in July & August 2013? Tonnes!
What's On at the Pickering Public Library in July & August 2013? Tonnes!What's On at the Pickering Public Library in July & August 2013? Tonnes!
What's On at the Pickering Public Library in July & August 2013? Tonnes!
 
Whats On May-June 2013
Whats On May-June 2013Whats On May-June 2013
Whats On May-June 2013
 
What's On Jan to April 2013
What's On Jan to April 2013What's On Jan to April 2013
What's On Jan to April 2013
 
Whats On at the Pickering Public Library for Sept - Dec 2012
Whats On at the Pickering Public Library for Sept - Dec 2012Whats On at the Pickering Public Library for Sept - Dec 2012
Whats On at the Pickering Public Library for Sept - Dec 2012
 
Pickering Public Library - What's On for Summer 2012
Pickering Public Library - What's On for Summer 2012Pickering Public Library - What's On for Summer 2012
Pickering Public Library - What's On for Summer 2012
 
What's On for May 2012
What's On for May 2012What's On for May 2012
What's On for May 2012
 
What's ON @ your library Jan - April 2012
What's ON @ your library Jan - April 2012What's ON @ your library Jan - April 2012
What's ON @ your library Jan - April 2012
 
Pickering Public Library - Living Library Event
Pickering Public Library - Living Library EventPickering Public Library - Living Library Event
Pickering Public Library - Living Library Event
 
Fall whats on_2011_vonline
Fall whats on_2011_vonlineFall whats on_2011_vonline
Fall whats on_2011_vonline
 

Último

4th Earthquake Drill Narraative Report.docx
4th Earthquake Drill Narraative Report.docx4th Earthquake Drill Narraative Report.docx
4th Earthquake Drill Narraative Report.docxJeneroseBaldoza
 
PPT TLE 7 and 8 Q3 AGRI CROP QUIZ 2.pptx
PPT TLE 7 and 8  Q3 AGRI CROP QUIZ 2.pptxPPT TLE 7 and 8  Q3 AGRI CROP QUIZ 2.pptx
PPT TLE 7 and 8 Q3 AGRI CROP QUIZ 2.pptxCrislynBaados
 
Monitoring songbirds' online market
Monitoring songbirds' online market Monitoring songbirds' online market
Monitoring songbirds' online market CIFOR-ICRAF
 
How do TOPCon Solar Cells/Solar Panel Work?
How do TOPCon Solar Cells/Solar Panel Work?How do TOPCon Solar Cells/Solar Panel Work?
How do TOPCon Solar Cells/Solar Panel Work?Bluebird Solar Pvt. Ltd.
 
Green Horizons: Ecotourism Conference 2024 in Amsterdam
Green Horizons: Ecotourism Conference 2024 in AmsterdamGreen Horizons: Ecotourism Conference 2024 in Amsterdam
Green Horizons: Ecotourism Conference 2024 in AmsterdamDIGITALCONFEX
 
Narrative Report on 3rd NNational Simultaneous Earthquake Drill2023.docx
Narrative Report on 3rd NNational Simultaneous Earthquake Drill2023.docxNarrative Report on 3rd NNational Simultaneous Earthquake Drill2023.docx
Narrative Report on 3rd NNational Simultaneous Earthquake Drill2023.docxJeneroseBaldoza
 
Item 6. Revision and consolidation of energy-related legal instruments
Item 6. Revision and consolidation of energy-related legal instrumentsItem 6. Revision and consolidation of energy-related legal instruments
Item 6. Revision and consolidation of energy-related legal instrumentsOECD Environment
 
Capacity Building in oil palm trade and sustainability
Capacity Building in oil palm trade and sustainabilityCapacity Building in oil palm trade and sustainability
Capacity Building in oil palm trade and sustainabilityCIFOR-ICRAF
 
Best-NO1 Best Black Magic Specialist Near Me Spiritual Healer Powerful Love S...
Best-NO1 Best Black Magic Specialist Near Me Spiritual Healer Powerful Love S...Best-NO1 Best Black Magic Specialist Near Me Spiritual Healer Powerful Love S...
Best-NO1 Best Black Magic Specialist Near Me Spiritual Healer Powerful Love S...Amil baba
 
How Long Does It Take Jackfruit To Bear Fruit?
How Long Does It Take Jackfruit To Bear Fruit?How Long Does It Take Jackfruit To Bear Fruit?
How Long Does It Take Jackfruit To Bear Fruit?EvergladesFarm
 
Item 2. a Update from the Secretariat
Item 2. a Update from the SecretariatItem 2. a Update from the Secretariat
Item 2. a Update from the SecretariatOECD Environment
 
The Dark Cloud of Global Air Pollution - Epcon
The Dark Cloud of Global Air Pollution - EpconThe Dark Cloud of Global Air Pollution - Epcon
The Dark Cloud of Global Air Pollution - EpconEpconLP
 
PBL Endangered and Vulnerable Species- Presentation.pptx
PBL Endangered and Vulnerable Species- Presentation.pptxPBL Endangered and Vulnerable Species- Presentation.pptx
PBL Endangered and Vulnerable Species- Presentation.pptxjabernethy
 
Incentive Scheme for Smallholders
Incentive Scheme for Smallholders Incentive Scheme for Smallholders
Incentive Scheme for Smallholders CIFOR-ICRAF
 
Supporting Farmer Transition to Produce Deforestation-Free Coffee
Supporting Farmer Transition to Produce Deforestation-Free CoffeeSupporting Farmer Transition to Produce Deforestation-Free Coffee
Supporting Farmer Transition to Produce Deforestation-Free CoffeeCIFOR-ICRAF
 
Purva Tranquillity best living place in East Bangalore
Purva Tranquillity best living place in East BangalorePurva Tranquillity best living place in East Bangalore
Purva Tranquillity best living place in East BangaloreNikki Harris
 
Third OECD-DOE Workshop Photo slide show.pdf
Third OECD-DOE Workshop Photo slide show.pdfThird OECD-DOE Workshop Photo slide show.pdf
Third OECD-DOE Workshop Photo slide show.pdfOECD Environment
 
Green Giraffe Advisory: Offshore wind market today.pdf
Green Giraffe Advisory: Offshore wind market today.pdfGreen Giraffe Advisory: Offshore wind market today.pdf
Green Giraffe Advisory: Offshore wind market today.pdfOECD Environment
 
Exploring the snake evolution (wild's gravity).pdf
Exploring the snake evolution (wild's gravity).pdfExploring the snake evolution (wild's gravity).pdf
Exploring the snake evolution (wild's gravity).pdfdrsk203
 

Último (20)

4th Earthquake Drill Narraative Report.docx
4th Earthquake Drill Narraative Report.docx4th Earthquake Drill Narraative Report.docx
4th Earthquake Drill Narraative Report.docx
 
International Day of Forests 2024
International Day of Forests 2024International Day of Forests 2024
International Day of Forests 2024
 
PPT TLE 7 and 8 Q3 AGRI CROP QUIZ 2.pptx
PPT TLE 7 and 8  Q3 AGRI CROP QUIZ 2.pptxPPT TLE 7 and 8  Q3 AGRI CROP QUIZ 2.pptx
PPT TLE 7 and 8 Q3 AGRI CROP QUIZ 2.pptx
 
Monitoring songbirds' online market
Monitoring songbirds' online market Monitoring songbirds' online market
Monitoring songbirds' online market
 
How do TOPCon Solar Cells/Solar Panel Work?
How do TOPCon Solar Cells/Solar Panel Work?How do TOPCon Solar Cells/Solar Panel Work?
How do TOPCon Solar Cells/Solar Panel Work?
 
Green Horizons: Ecotourism Conference 2024 in Amsterdam
Green Horizons: Ecotourism Conference 2024 in AmsterdamGreen Horizons: Ecotourism Conference 2024 in Amsterdam
Green Horizons: Ecotourism Conference 2024 in Amsterdam
 
Narrative Report on 3rd NNational Simultaneous Earthquake Drill2023.docx
Narrative Report on 3rd NNational Simultaneous Earthquake Drill2023.docxNarrative Report on 3rd NNational Simultaneous Earthquake Drill2023.docx
Narrative Report on 3rd NNational Simultaneous Earthquake Drill2023.docx
 
Item 6. Revision and consolidation of energy-related legal instruments
Item 6. Revision and consolidation of energy-related legal instrumentsItem 6. Revision and consolidation of energy-related legal instruments
Item 6. Revision and consolidation of energy-related legal instruments
 
Capacity Building in oil palm trade and sustainability
Capacity Building in oil palm trade and sustainabilityCapacity Building in oil palm trade and sustainability
Capacity Building in oil palm trade and sustainability
 
Best-NO1 Best Black Magic Specialist Near Me Spiritual Healer Powerful Love S...
Best-NO1 Best Black Magic Specialist Near Me Spiritual Healer Powerful Love S...Best-NO1 Best Black Magic Specialist Near Me Spiritual Healer Powerful Love S...
Best-NO1 Best Black Magic Specialist Near Me Spiritual Healer Powerful Love S...
 
How Long Does It Take Jackfruit To Bear Fruit?
How Long Does It Take Jackfruit To Bear Fruit?How Long Does It Take Jackfruit To Bear Fruit?
How Long Does It Take Jackfruit To Bear Fruit?
 
Item 2. a Update from the Secretariat
Item 2. a Update from the SecretariatItem 2. a Update from the Secretariat
Item 2. a Update from the Secretariat
 
The Dark Cloud of Global Air Pollution - Epcon
The Dark Cloud of Global Air Pollution - EpconThe Dark Cloud of Global Air Pollution - Epcon
The Dark Cloud of Global Air Pollution - Epcon
 
PBL Endangered and Vulnerable Species- Presentation.pptx
PBL Endangered and Vulnerable Species- Presentation.pptxPBL Endangered and Vulnerable Species- Presentation.pptx
PBL Endangered and Vulnerable Species- Presentation.pptx
 
Incentive Scheme for Smallholders
Incentive Scheme for Smallholders Incentive Scheme for Smallholders
Incentive Scheme for Smallholders
 
Supporting Farmer Transition to Produce Deforestation-Free Coffee
Supporting Farmer Transition to Produce Deforestation-Free CoffeeSupporting Farmer Transition to Produce Deforestation-Free Coffee
Supporting Farmer Transition to Produce Deforestation-Free Coffee
 
Purva Tranquillity best living place in East Bangalore
Purva Tranquillity best living place in East BangalorePurva Tranquillity best living place in East Bangalore
Purva Tranquillity best living place in East Bangalore
 
Third OECD-DOE Workshop Photo slide show.pdf
Third OECD-DOE Workshop Photo slide show.pdfThird OECD-DOE Workshop Photo slide show.pdf
Third OECD-DOE Workshop Photo slide show.pdf
 
Green Giraffe Advisory: Offshore wind market today.pdf
Green Giraffe Advisory: Offshore wind market today.pdfGreen Giraffe Advisory: Offshore wind market today.pdf
Green Giraffe Advisory: Offshore wind market today.pdf
 
Exploring the snake evolution (wild's gravity).pdf
Exploring the snake evolution (wild's gravity).pdfExploring the snake evolution (wild's gravity).pdf
Exploring the snake evolution (wild's gravity).pdf
 

Better Builder Issue 8

  • 1. IN THIS ISSUE »» One of the Best – Steve Tobey Takes Us Back to School »» Best Choices for Addressing 2017 OBC Changes »» Best Demo Projects of the Past »» Best Approaches for Designing Mechanicals »» Best Way to Renovate – Integrating the Past, Present and Future BETTER BuilderMAGAZINE the builder’s source Looking Back and Moving Forward Simply the Best ISSUE 08 | WINTER 2014 WWW.BETTERBUILDER.CA
  • 2. A b r e a t h o f f r e s h a i r . MAX SERVICE All mechanical and electrical components are accessible from the front of the unit. Heating coil and fan/motor slide out for easy service. One of the most extensive warranties in the business:1-year parts & labour,2-years on parts only,where applicable. MAX COMFORT With the increased efficiency of this optional Electronically Commuted Motor (ECM), homeowners will be free to cycle air continuously with a minimal increase in electricity cost. Continuous fan operation helps improve filtration,reduce temperature variations,and helps keep the air clear of dust and allergens – making your customers’ homes more comfortable. Mini Ducted Hi-Velocity Air Handling System Optional Prioritizing of Comfort Levels with Energy Savings MAX SPACE SAVER The MAXAIR fan coil is so compact that it fits anywhere:laundry room,attic,crawl space,you can even place it in a closet. It can be installed in new or existing homes. It takes less than 1/3 of the space of a conventional heating and air conditioning unit. MAX ENERGY SAVINGS Energy savings,temperature control and comfort levels are achieved in individual levels of the home by prioritizing the requirements.This is achieved by installing optional space thermostats. If any area calls for heating or cooling, the individual thermostat allows the space it serves to achieve optimum comfort and still maintain continuous air circulation throughout the home. This method of prioritizing is a great energy savings measure while offering an increased comfort level to the home owner. FLEXAIRTM DISTRIBUTION SYSTEM MAX FLEXIBILITY The supply outlets can be placed in the wall, ceiling or floor. Each unit has four choices of locations for the return air connections. The FLEXAIR™ insulated 2½" supply duct will fit in a standard 2"x 4" wall cavity. Can be mounted for vertical or horizontal airflow. Can be combined with humidifiers,high efficiency air cleaners or ERVs / HRVs. Snap-together branch duct and diffuser connections. MAX ELECTRICAL SAVINGS ECMs are ultra-high-efficient programmable brushless DC motors that are more efficient than the permanently split capacitor (PSC) motors used in most residential furnaces.This is especially true at lower speeds used for continuous circulation in many new homes. 1-800-453-6669 905-951-0022519-578-5560613-966-5643 416-213-1555 877-254-4729905-264-1414 For distribution of Air Max Technologies products call www.airmaxtechnologies.com209 Citation Drive, Units 5&6, Concord, ON L4K 2Y8, Canada
  • 3. FEATURE STORY 16 Steve Tobey Takes Us Back to School BY TRACY HANES INSIDE THIS ISSUE 02 Publisher's Note: Simple is Best BY JOHN GODDEN 03 The Best Way Forward to 2017 BY LOU BADA 04 Straight From the Hart: Best Demonstration Projects of the Past BY LEN HART 06 Best Approach for Right Sized Mechanical Systems BY GORD COOKE 08 The Best Way to Ventilate BY PANASONIC CANADA AND BETTER BUILDER STAFF 10 The Real-World Science Behind Better-Built, Better-Performing Homes BY DOW BUILDING SOLUTIONS 13 Net Zero Housing Design Simulated – Case Study BY MICHAEL LIO AND CEARA ALLEN 22 The Best Way to Renovate – Integrating the Past, Present and Future BY ALEX NEWMAN 26 The Best Way to Insulate Basement Floors BY HOWARD COHEN AND BETTER BUILDER STAFF 28 The Best New Demo Project BY DOUG TARRY 31 The ARGILE Project: Building Science Research at George Brown College BY THE ARGILE RESEARCH TEAM BETTER BuilderMAGAZINE the builder’s source 1 16 ISSUE 08 | WINTER 2014 WWW.BETTERBUILDER.CA | ISSUE 08 | WINTER 2014 3 6 22
  • 4. PUBLISHER BETTER BUILDER MAGAZINE 12 ROWLEY AVENUE TORONTO, ON M4P 2S8 416-481-4218 - FAX 416-481-4695 SALES@BETTERBUILDER.CA BETTER BUILDER MAGAZINE IS A SPONSOR OF PUBLISHING EDITOR JOHN B. GODDEN JOHNG@BETTERBUILDER.CA MANAGING EDITOR WENDY SHAMI EDITORIAL@BETTERBUILDER.CA To advertise, contribute a story, or join our distribution list, please contact sales@betterbuilder.ca FEATURE WRITER TRACY HANES CREATIVE ANNA-MARIE MCDONALD LITTLE GREEN BAG CREATIVE SERVICES THIS MAGAZINE BRINGS TOGETHER PREMIUM PRODUCT MANUFACTURERS AND LEADING BUILDERS TO CREATE BETTER, DIFFERENTIATED HOMES AND BUILDINGS THAT USE LESS ENERGY, SAVE WATER AND REDUCE OUR IMPACT ON THE ENVIRONMENT. PUBLICATION NUMBER 42408014 Copyright by Better Builder Magazine. Contents may not be reprinted or reproduced without written permission obtained at info@clearsphere.ca. The opinions expressed herein are exclusively those of the authors and assumed to be original work. Better Builder Magazine can not be held liable for any damage as a result of publishing such works. UNDELIVERABLE MAIL BETTER BUILDER MAGAZINE 12 ROWLEY AVENUE TORONTO, ON M4P 2S8 BETTER BUILDER MAGAZINE IS PUBLISHED FOUR TIMES A YEAR BY 2 PUBLISHER’S NOTE Simple is Best It’s hard to believe that almost two years have passed since the first issue of Better Builder. Over this period we have endeavoured to bring our readers simply the best articles and content. Can you hear Tina Turner singing? I can, and with her song playing in the back of my mind, I am aware of the fact that when it comes to a lot of things in life, building included, simple is best. In this issue, Better Builder takes a look back at a number of the innovations, products and builders that were successful in their respective markets. They are identified as the very necessary ingredients to be integrated and executed, for a smooth transition into 2014 all the while keeping in mind the new code to come in 2017. In the feature story of our most recent issue of Better Builder we unfortunately misspelled the name of the president of Garden Homes. Mr. Ignazio Giardina is not only a craftsman in the time-honoured manner – he came to Canada 45 years ago as a cabinetmaker – but he is meticulous in his approach to every home he builds. Mr. Giardina researches thoroughly before he builds a home, looking for the latest and best materials and methods to make sure the end product is as durable, and as energy efficient as humanly possible. Anything that Mr. Giardina believes can improve the end result is tested first on his own home. Better Builder, likewise, aims to do its best, providing the latest and best information about sustainable building practices. Sometimes things slip through, but when it’s brought to our attention, we appreciate feedback so that we can correct it. Long time R2000 Builder and friend Steve Tobey takes us back to school on a project that takes old and makes it new. A new build replicates a century-old schoolhouse and meets Energy Star 12.1 and becomes part of Project FutureProof. Lou Bada looks back at LEED/TAP and two years later a demonstration house is occupied and functioning without any glitches. Lenard Hart reviews 4 demonstration projects of the past and assesses them on their impact. For almost 25 years CSA F280 has been used as a standard to design residential mechanical systems; Gord Cooke outlines the changes in the new revised standards that will result in the best designs for right-sized heating plants and distribution systems. Alex Newman reports on builder/renovator Amedeo Barbini who is transforming a 1950 bungalow into a luxury two-story home that reflects the local value of real estate in Don Mills. Thirty years after the R2000 program has been introduced, Michael Lio reports on designs for Net Zero Housing. Dow Building Solutions is monitoring real-world out- comes behind better built, better performing homes under the TEETH Project. Doug Tarry Homes has achieved a true demonstration of new products in his Optimum Home. Right-sized heating equipment, a sealed air-distribution system, and a monitored basement wall highlight the best examples of how homes can be better built. We hope you will agree this issue of Better Builder is simply the best. JOHN GODDEN
  • 5. BUILDER NEWS 3 The Best Way Forward to 2017 It has been two great years since I began contributing to Better Builder magazine, and as we look back on past topics of discussion, I feel this is a good opportunity to look forward to emerging issues as well. Looming in the distance are changes to the Ontario Building Code’s energy efficiency requirements in 2017. I began almost two years ago by writing about our LEEP/TAP Discovery Home (ERS 83/HERS 44) which, at the time, helped inform us on the current redundancies of SB-12 in the OBC. The exercise was also intended to give us insight into what would be required to achieve the projected energy conservation goals of the next Code cycle. At the time, we utilized just about every off the shelf premium technology at our disposal to meet the expectations of the 2017 code. Technologies such as: upgraded right-sized mechanicals (combination heating system, high efficiency HRV and bathroom fans), renewable systems such as, Drain Water Heat Recovery, building envelope details with insulated sheathing, high density and foam insulation and Zone C windows, improved air barrier detailing, electrical savings with ECM motors and efficient lighting (LED and CFL), water conservation with a re-circulating hot water system and dual flush toilets. It is of import to note that all systems are running well in the Discovery homes we have worked on to date, and our homeowners have not run into any problems…as well they shouldn’t, given that these are all proven technologies. Looking forward, future proofing, in the form of rough-in grey water recycling and solar ready for PV are certainly on the table for serious consideration in discussions concerning sustainable building practices. Further, these systems could have been utilized in the LEEP/TAP home. And, as we’ve seen, accommodations are being made in the OBC in regards to grey water recycling. However, I believe we are approaching the limit of where off the shelf technologies will give us a reasonable return. Having said that, some wiggle-room still exists by lowering further still air infiltration and increasing mechanical efficiencies. Unfortunately, they will only take us so far. Re-use and renewable technologies will become more relevant, but not until the technologies have completely matured and are economically viable, especially in cases where freshwater, waste and storm water are concerned. I believe, for the OBC to move forward, a broader perspective will need to be taken in regards to water and its impact on building efficiency, energy consumption and infrastructure. Finally, there must be a value proposition (and perception) for our customers; affordability is always an issue. This will require people with common sense and goodwill in this industry and in government, working together towards a common goal. Flexibility and innovative thinking in terms of the societal costs and benefits of building more efficient homes will be paramount in the coming years, in contrast to the conventional thinking we’ve experienced thus far. ISSUE 08 | WINTER 2014 LOU BADA LOU BADA IS THE CONSTRUCTION & CONTRACTS MANAGER FOR STARLANE HOMES
  • 6. 4 Straight from the Hart BEST DEMONSTRATION PROJECTS OF THE PAST It has been two years since Better Builder magazine was created, taking the place of its predecessor Sustainable Builder magazine, and I thought this would be an opportune time to review some of the many projects covered over these last few years. Personally, I am grateful for the plethora of projects I have been involved with, and take pride in how the industry has evolved to produce better homes. Unfortunately, many of the challenges we faced still remain unresolved. For the second issue of Sustainable Builder magazine (summer 2009) we had the three elected heads of the big HBAs on our cover (BILD, Ontario and Canada). All three were green-builders so we titled the issue, Everybody’s Green. At the time, we thought that leading positions were being given to green-builders simply because they were green builders. Now it seems as though green-building is more ubiquitous than ever, no longer a badge of distinction, but rather that it is something that everyone should be implementing. The changes to the building code have certainly been a factor, as well as the influence of the market. Back in 2009, the ever insightful Stephen Dupuis talked about the ten green-guys; the few key movers who were behind all the green-projects in the industry. Today, there are literally hundreds of green- professionals; builders, engineers, Energy Star compliance officers, etc. What it means to be green or sustainable is essentially a contested concept. Like democracy or beauty, the definition is arbitrary and changes as frequently as debates continue as to what should or shouldn’t be included. Lately, it seems as though too much has been included, thus diminishing the concept’s value. Energy Star has always been a double- edged sword for me. It was the program that got production builders thinking about building above code, but it was clearly a lower level achievement compared to R-2000, LEED Platinum, Net Zero, or Passive House. It should come as no surprise that the Green/Sustainable/Energy Efficient label does not carry the weight it used to. With thousands of homes being built to the current code, getting the Energy Star label was far too easy, mostly because they were enrolled under the old standard. Consumers expect the Energy Star label to have meaning, and under the new standard it will again. However, the market for more energy efficient homes seems to have hit a plateau despite the fact that climate change and rising energy costs still persist. Perhaps new homes are too far ahead of existing homes when it comes to energy efficiency. For example, I used to live in a LEED Platinum home, rated 85 on the EnerGuide scale. Now, I live in a 1920s full-brick house with some modest insulation upgrades. My utilities bills are triple what they were in the LEED house; from $95 to $315 per month. Yet I live in Bloor West now instead of New Market, and my commute is ten to twenty minutes. Since my commute has shortened, I drive much less and my overall carbon footprint is about the same. For me the question is simple: is it worth the extra monthly utility costs to live where I live? In short, the answer is yes. Going forward, the challenge seems to be how to get an individual to invest $20,000 or more on a retrofit upgrade that will save them only $150-$200 per month. Despite how far we have come in terms of new technologies and new homes, the old payback problem still exists. Aside from the Energy Star program, I was lucky enough to have some involvement with four significant Green Projects over the last few years that I would like to reflect upon in retrospect. Rodeo Fine Homes and the Town of Newmarket – This project arose when the town offered a discount on a large undeveloped piece of land, on the basis that builders would meet the conditions of Platinum rating. Rodeo Fine Homes won the bid to build the subdivision and proposed to meet the standard using the LEED for Homes rating system. The result was 34 comfortable, quiet, highly efficient homes in a quiet part of Newmarket. To get to the LEED Platinum rating there was a large reliance on very advanced technology, which resulted in plenty of maintenance issues, but also significant challenges in finding knowledgeable trades to service the homes. Ultimately, the project was ahead of its time, especially for the area, where code-built monster homes tend to be the main competition. I bought one, and upon resale, I was unable to recoup any above market pricing for the green upgrades, but still it was by far the best performing home I have ever lived in. From an industry perspective, I am not sure other builders are looking to this model, not even Rodeo is building like this anymore. BUILDER NEWSBUILDER NEWS LEN HAR T
  • 7. 5 NOW House –This was a “Net Zero-inspired” retrofit to a post-war CMHC bungalow. At the design charette there was extensive focus on how to produce an affordable high efficiency retrofit, but sponsorships changed the project to be more about what is possible than what is feasible. A real homeowner got significant benefits that improved his small home’s energy efficiency, but it was not a good template for others. It was too expensive, and for all that money it did not add any square footage. The retrofit itself seemed to pale in comparison to the well packaged and well promoted retrofits in the road show that followed. In the end the retrofit was dominated by the sponsor’s offerings. It was too much money to spend for an energy retrofit. The promotional road show was successful as a sales tool for some retrofits. Green Home Makeover – A TRCA neighborhood level initiative, in which a dedicated community resource person promoted energy and water conservation to a community with a contest to give away a home retrofit to one lucky resident. The project addressed the issue of getting home owners to retrofit their homes and served as a demonstration project for the community. However, other than the free makeover winners, nobody else really did any significant retrofit work. The key partners in this project were local and regional governments, who along with the TRCA were most interested in watershed issues and managing run off. Ultimately that is a tough sell with very little payback. The energy retrofit was added to round out the offerings, but it did not result in much uptake. The Archetype Sustainable House – A TRCA sponsored design contest aimed at showing the future of home building. Once a design was chosen, the TRCA partnered with BILD to construct the demonstration homes at the Kortright Centre using donated materials and volunteer labour. Two unique and informative demonstration homes now exist and are regularly toured. The partnership between TRCA and BILD was a significant achievement and a major part of Stephen Dupuis' lasting legacy. The home construction process suffered from a lack of resources, despite significant contributions from BILD members, many compromises had to be made and some decisions were based purely on what was available. The architects who designed the homes were quite new to the industry, so there were some growing pains that were compounded by the volunteer build model. This put a lot of pressure on those actually trying to get the homes built, such as Alex Waters, Larry Brydon, and Fred Serrafero. In the end, the project was a significant achievement that still has relevance and is still toured today, but did it change anything? All of these projects aimed high and involved much negotiation and compromise, all had multiple strategic collaborations and multi-sector partners (including governments, associations, and sponsors), and all tried to effect change in the way we build and retrofit homes. Each was successful in its own way, but each also gave us a learning opportunity. In looking forward, I hope we see projects that continue to advance green-building. If pressed, I would say the four areas where we should see some real advances are: building envelopes, production quality, smart technology, and deep retrofits… but these are for future issues. ISSUE 08 | WINTER 2014 BUILDER NEWS LENARD HART IS THE BUSINESS DEVELOPMENT DIRECTOR AT GREENSAVER A NOT-FOR-PROFIT ENVIRONMENTAL ORGANIZATION FOCUSED ON RESIDENTIAL ENERGY EFFICIENCY AND CONSERVATION PROGRAMS. HE WAS ONE OF THE DEVELOPERS OF THE ENERGY STAR FOR NEW HOMES PROGRAM IN ONTARIO AND THE FORMER PUBLISHING EDITOR OF SUSTAINABLE BUILDER MAGAZINE. Project Pros Cons Learning Grade Newmarket LEED Platinum Showcased ground breaking technology, Town was a partner Too far ahead of the curve, and too much tech for home buyers A- NOW House retrofit Responded to specific homeowner need, promoted widely Lost its way when sponsors offered more than needed C+ Green Home Makeover Community based, addressed energy, water draw and run off Free upgrade lead to little community uptake, despite all the efforts C- Archetype BILD/TRCA partnership, hundreds of tours, Ryerson monitoring Redundant showcase systems, unclear how it changed building B+
  • 8. BUILDER NEWS 6 I have been fielding calls recently from manufacturing folks with southern accents asking about changes they have heard about with respect to the need for smaller furnaces in Canada. They are referring of course to the publishing of the new CAN/CSA F280 Standard “Determining the Required Capacity of Residential Space Heating and Cooling Appliances” and the impact it will have on the size of furnaces that will be needed in Canadian homes when the standard is referenced in building codes and adopted as standard practice in the coming months. The US furnace manufactures I am speaking to seem surprised by this “sudden” change, but they shouldn’t be. After all the old F280 Standard was written in 1990 and when it was written there were notes in the appendices suggesting the standard needed better ways to handle the emerging trend at that time for tighter homes with more efficient ventilation systems. HVAC designers will know that in the current 1990 CSA F280 these two components, air leakage and ventilation, typically account for as much as 40-50% of the overall design heating load for a home. A short 23 years later, the new standard does indeed address the fact that all new homes are much tighter than the old standard ever anticipating being possible and heat recovery ventilation is now a common component in new homes and in 1990 there was no allowance for this type of device. Combine that with updates to the standard in the way foundation heat loss is modeled and recognition of the new window glazing options now available to builders that optimize both heating and cooling impacts and it should be no surprise at all that a heating and cooling system designed under the new CSA F280 should be significantly smaller than systems designed using the algorithms in the existing standard. That said, it does take some getting used to when you consider the table below showing the results for a 2 – storey, 2200 square foot home in Newmarket, ON built to current Ontario Building Code requirements, using Package J insulation and mechanical system requirements under the old and new standard. It means a home that used to get a 70,000 BTU/Hr furnace now needs only a 40,000 BTU/Hr model. Of course, most furnace manufactures do have 40,000 – 50,000 BTU/Hr models. The real issue for manufacturers is the recognition that as many as 50% of homes built in Canada last year were smaller multi-family, attached dwellings that, using the new CSA F280, have design heat losses well below 30,000 BTUs/Hr. As Doug Tarry of Doug Tarry Homes in St. Thomas, ON reported in a previous article, this new sizing validates why many builders are having problems meeting the comfort expectations of their customers. That is, if we were assuming a house needed a 70,000 BTU/Hr furnace on the coldest day of the year and it really it only needs a 40,000 BTU/Hr furnace you can expect issues. It means that the furnace runs just half the time on a cold day and rooms that have higher than average rates of cooling, like a room over a garage, that room is going to be cold. Homeowners think this cold room scenario means the furnace is too small, while the new CSA F280 sizing would confirm the issue is the furnace is too big and thus doesn’t run long enough to ensure adequate heat flow to all rooms in the house. Of course, if homes in Canada need smaller furnaces, you can imagine that homes in milder US climates would also be affected, so why haven’t US manufactures seen this issue there? There may be two reasons. First, those milder climates don’t result in the high rates of cool down that we experience in cold weather, so while some rooms in a home might be cooler than others, the effect isn’t particularly dramatic. Second, zoning of HVAC systems in the US has become much more common than in Canada, primarily to solve summer cooling comfort expectations, but it will help balance winter temperatures as well. Best Approach for Right Sized Mechanical Systems GORD COOKE Total Heat Loss BTUs/hr Air leakage component of Heat Loss BTUs/hr Total Heat Gain BTUs/hr Current CSA F280 55,425 13,225 31,250 New CSA F280 33,875 4,020 26,150
  • 9. Of great interest, while the US manufacturers will someday respond to this need for smaller furnaces, one Canadian manufacturer has already stepped up. Dettson Industries in Quebec, a long standing excellent boiler manufacturer, has entered the forced air industry at just the right time with a full series of high efficiency, multi-stage furnaces, but most importantly one that has a smaller capacity. In fact, as Doug Tarry reported, they have installed a unit in St. Thomas that has a capacity of just 30,000 BTUs/Hr. It is nice to see Canadian manufactures supporting the initiatives of Canadian builders. May I suggest that this winter will be a great time for builders and their HVAC contractors and designers to recalibrate their thinking of what constitutes a properly sized furnace. Starting tomorrow, install a thermostat on at least one of your homes that can monitor run times of furnaces. Many commonly available thermostats can do this, like the web- based stat EcoBee. Now you check over this winter just how often the furnaces you are using now are operating during the coldest periods and this will help you accept the reality that smaller furnaces with smaller duct work can improve comfort, save space and perhaps be even just slightly less expensive to install – a great win-win from all your hard work to improve the energy efficiency of your homes. 7 BUILDER NEWS ISSUE 08 | WINTER 2014 Clears the room faster than Charlie Sheen. Vigör is worth a tweet or two. Our lowest priced HRV/ERV delivers powerful ventilation for small spaces. It’s so easy to install, you’ll wonder why you ever chose anything else. Now that’s winning. Perfection. Cubed. Visit vanee-ventilation.com to learn more. VEN_Ad_MB_Jun2311.indd 1 11-06-24 9:29 A GORD COOKE IS THE PRESIDENT OF BUILDING KNOWLEDGE CANADA DETTSON RIGHT SIZED FURNACE INSTALL AT DOUG TARRY HOMES.
  • 10. ATTENTION: HOME BUILDERS Introducing a revolutionary new product that eliminates dirty, dusty floor vents during home construction. Forever. Our product is made from recycled materials. Made in Canada. by preventing dust, dirt, and garbage from entering the duct -work. on to detail = enhanced customer satisfaction. design. NEW PRODUCT www.protecvent.com 905.532.0722 BUILDER NEWS The Best Way to Ventilate In the world of bathroom ventilation fans there are a plethora of options available to builders and consumers, but which one to choose? Aside from expelling moisture and odour, the criteria for this decision revolves around three main areas; the products affordability, its energy efficiency and how much noise it produces. Panasonic has striven to meet these additional criteria with their line of bath fans called Whispergreen DC. Not only is this line of fans 30% less expensive than most other models, its enclosed DC motor ensures a longer life-span (rated for 60 000 hours of continual use) and comes with a six-year warranty. This line of fans has earned the highest performance rating from the US EPA ENERGY STAR program, the most efficient label, and two of the variable speed models have the distinction of having the highest efficacy rating on the entire list, at 23.3 CFM/W. This level of efficacy far exceeds the ENERGY STAR minimum of 1.4 CFM/W for this CFM flow. One of the many features that have made these fans the industry performance leaders for the past six years is the built-in Smart-Flow technology that maintains a constant level of airflow over a wide range of static pressures. Each fan has a chip that measures the fan RPM and amperage draw many times per second, and determines if the fan needs to speed up or slow down to maintain the chosen airflow rate. This means that if 50 CFM airflow is chosen, the installer or tester will see 50 CFM (+/-5- 10%) over a range of zero static to upwards of 125 Pa. This is not a static setting or single-time commissioning; this technology controls the airflow even with a drastic change in static pressure caused by wind or stack effect or by other fans discharging into the same shaft in a multifamily building. They even maintain that airflow under negative pressure. The fans are constantly sampling and adjusting the speed to maintain the set airflow for the life of the fan. When the fan is turned off- or the optional motion sensor detects no movement – it will automatically wait a predetermined period of time and then drop back down to the base- line CFM level. This not only saves on energy consumption, but minimizes the amount of noise it produces. Scott Ingram, a Toronto resident, had the Whispergreen DC installed in his three-bed- room Leaside home just under a year ago and couldn't be more pleased with the result. “We got it for our en suite bathroom on the third floor of our house,” Ingram said. “The thing is so quiet the only way to tell that its on is by the green light on the LCD monitor... Not only does it clear all the moisture and odour from the bathroom within minutes, we even use it when we cook because it clears those odours too, from three floors away!” The product was recommended to him by an industry expert and Ingram says that he would buy it again, and thinks everyone should have one. Panasonic offers five single speed Whispergreen models, the 50, 80 and 110 CFM fan-only models and two CFL light versions of the 80 and 110 CFM models. Whether it is a commercial, multifamily, or single-family project, these single speed DC fans are a great choice. In one condo project in Hawaii, 950 50 CFM fans were installed in a 37- storey building. The Smart-flow technology of these fans meant that the HVAC con- tractor provided 50 CFM of exhaust in every unit, no matter what floor and no matter how many were discharging into these very tall fire-rated shafts. The Test and Balance contractor had hardly anything to adjust. PANASONIC CANADA AND BETTER BUILDER STAFF
  • 11. Providing effective ventilation solutions for today’s high performance housing. Do you really want to install the same old fans in your next project? You can differentiate yourself as a sustainable builder by choosing Energy Star qualified Panasonic WhisperGreen™ ventilation fans. WhisperGreen™ fans are designed to provide both continuous whole house and spot ventilation for improved indoor air quality. The automatic variable speed control allows the fan to run continuously at a pre-set lower level for whole house ventilation. Turning on the switch or activating the motion sensor elevates the fan to a maximum level of operation for effective spot ventilation. Quiet, powerful and energy efficient, Panasonic ventilation fans are also Energy Star, LEED, and ASHRAE 62.2 compliant making them a wise choice in sustainable building. Learn more by visiting panasonic.ca or email VentilationFans@ca.panasonic.com, or call 1-800-669-5165. *Comparison with ENERGY STAR requirement of minimum efficacy level of 1.4 CFM per watt for 10-80 CFM fans and 2.8 CFM per watt for 90-130 CFM fans.
  • 12. BUILDER NEWS 10 BUILDER NEWS DOW BUILDING SOLUTIONS The Real-World Science Behind Better-Built, Better-Performing Homes When it comes to residential home construction, Dow knows that homebuilders and remodelers want to be 100 percent sure that the products and solutions you’re using are increasing the comfort, durability, quality and value of the homes you build. Part of our job at Dow Building Solutions is to ensure that we understand the science behind the building and use that knowledge to help YOU create homes that meet or even outperform Ontario’s building codes. By helping you outperform codes, we can help you create homes that provide long-term comfort, lower utility bills and durability for your home buyers, an enhanced reputation for you and growing bottom line for your business. Backed by The Dow Chemical Company’s 100+ years of experience, we believe in the importance of testing our insulation and air sealing solutions and understand that our testing must extend beyond the lab into where it matters most – the real world. TWELVE ENERGY EFFICIENT TEST HOMES (TEETH) PROJECT There is a real-world case study taking place right now in Midland, Michigan. Spearheaded by Dow Building Solutions and Cobblestone Homes of Saginaw, Michigan, the Twelve Energy Efficiency Test Homes (TEETH) Project was several years in the making. The goal of this project is to create the first- ever forum for real-world, real- time measurements that track and capture data of high-performance homes. The project consists of 12 homes, built in Midland, MI, U.S. Climate Zone 5/6 (equivalent to Ontario’s <5,000HDD Climate Zone), that are not just test facilities, but homes in which real families live. The TEETH neighborhood is made up of four different energy performance insulation and air sealing packages and three different floor plans. Each of the four energy performance packages features a different combination of insulation and air sealing improvements, including continuous insulation, closed-cell spray foam insulation and insulating foam sealants*. Home construction was completed in 2011 and the full study launched in fall of 2012 after the last home was occupied. ENERGY PERFORMANCE DESIGN PLAN BUILDING CODE MET Baseline Performance Minimum Cost HERS 82 Meet 2006 IECC at lowest possible price point 2012 Energy Performance Minimum Cost HERS 57 Meet 2012 IECC at lowest possible price point 2012 Outperformance Home HERS 57 Meet 2012 IECC building science best practices Beyond Code: Renewable Ready HERS – mid 40s Exceed 2012 IECC Renewable ready
  • 13. BUILDER NEWS ENSURING VALIDITY To ensure the validity of the study, each home was uniformly built to exacting standards designed to mitigate variances, including orientation to the sun and grade. The 12 test homes are comparable in size, floor plan and all other key features with the exception of the insulating and air sealing systems. It is important to note that the families living in the TEETH homes are not aware of which energy performance model home they are living in. This allows for residents to conduct their normal energy consumption habits without awareness of the energy performance of their dwelling, which helps to ensure the data collected is unbiased. With the data collected, we are able to accurately test how building products and systems behave together. GATHERING DATA The TEETH Project represents the country’s first active subdivision dedicated to the purpose of collecting and analyzing building performance data. Each home has a Data Acquisition Box in its basement to collect information relating to energy consumption, humidity, moisture levels, heat flow, and temperature – all key contributors towards a homes energyefficiency. YEAR-ONE DATA ANNOUNCED IN FEBRUARY AT 2014 INTERNATIONAL BUILDER’S SHOW IN LAS VEGAS, NV While the homes were built in 2011, they all weren’t fully occupied until the summer of 2012, so our research didn’t begin until the winter season of 2012-2013. Now that we are one year into the project we have the first year’s data realized. Dow is currently analyzing this data and is scheduled to present our findings in a presentation at the 2014 International Builder’s Show, February 4-6 in Las Vegas, NV. The TEETH Project is just one example of Dow’s ongoing commitment to gathering realworld data that allows homebuilders and homeowners to see how building a better performing home benefits both builders and homeowners. Building Outperforming Homes helps you, the builder, differentiate yourself from your competition and grow your business and reputation by offering homeowners long-term comfort, efficiency, savings, and overall home durability. For more information on Dow’s TEETH Project and more of our building science real world proof, please visit our website or contact Dave Kelly, (416)460-9876, Senior Building Envelope Specialist for Ontario. *Although built using US building codes as a reference point, these homes will provide data points showing the value of insulation & air sealing upgrades throughout the United States and Canada ®TM Trademark of The Dow Chemical Company (“Dow”) or an affiliated company of Dow 11ISSUE 08 | WINTER 2014 The Power-Pipe® uses outgoing warm drain water to pre-heat incoming cold freshwater in Residential, Commercial and Industrial, thereby reducing energy costs. TURN THAT WASTED ENERGY INTO $AVING$ WITH THE www.power-pipe.com Saving Energy Intelligently E N E R G Y I N C . Developed and Manufactured by: LOWER ENERGY BILLS. GREAT RETURNS. Drain Water Heat RecoverySystems H O W I T W O R K S ® GreenBuild 8x10 Pstr3_Print.pdf 5/7/12 10:34:54 PM
  • 14. www.inlinefiberglass.com 1.866.566.5656 INLINE FIBERGLASS LTD.can help your clients meet their energy and thermal performance targets in most cases without the use of special designs or expensive glass options. Call us to discuss your next project and find out why our windows are chosen often for LEED designs, Passive Homes, Healthy Homes, Health Centers, Hospitals, Schools, Fire Stations, Hydro Offices, Retirement Homes, Nursing Homes . . . MEMBER/MEMBRE Unison Community Health Centre / Architect: Hilditch Architect / Constructor: Buttcon Limited INLINE FIBERGLASS LTD. Covering all your angles, SB10, SB12, Energy Star, NFRC, High Performance Window Products
  • 15. 13 Many across North America hope to see homes built to Net Zero standards by 2030. The idea of a Net Zero Energy (NZE) home is that it employs enhanced energy efficiency design strategies to cost effectively reduce energy needs, while meeting those needs with renewable energy technologies.The result is a building that consumes equal to or less energy than it produces on an annual basis. The federal government, through the ecoENERGY Innovation Initiative (ecoEII), is funding a cross-Canada demonstration project of Net Zero homes in the context of housing production. The project focuses on affordability and market acceptability of Net Zero homes. The project proponent, Owens Corning Canada, is working with five builders in four provinces to build at least 25 Net Zero homes. To build a Net Zero home, the first efforts focus on conservation by maximizing the envelope and air tightness levels, and by including high performance mechanical systems. Reduction in energy consumption means that lower energy generation technologies are required. Energy efficient technologies are generally much less costly than those that generate energy. It makes little sense to install hundreds of photovoltaic (PV) panels on a leaky and poorly insulated house to achieve a Net Zero balance. To understand the impacts of energy conservation measures, such as upgrading the envelope or reducing air leakage, the buildABILITY team modelled various scenarios in HOT2000 using the Ontario Archetype house. The goal of the exercise was to see how much the calculated annual energy consumption of the Archetype House could be reduced before renewable technologies were considered. Various levels of insulation were examined for the ceiling, walls, basement walls, and underneath the slab. Several U-values and solar heat gain coefficients (SHGC) were investigated for windows. A number of high performance mechanicals were considered and modelled. The systems that were finally selected are shown in Table 1. The modelling exercise was intended to see how much the annual energy consumption could possibly be reduced; the simulations did not consider costs. The NZE homes that will be built for the ecoEII project use the new EnerGuide Rating System for New Homes to measure energy use, and in many cases use the new R-2000 requirements as the jumping off point to achieve Net Zero. The new R-2000 program includes reduced base loads, electrical base loads are 16 kWh/day, domestic hot water loads are 143 L/day, and the occupant numbers are reduced to two adults and one child. These were incorporated into the buildABILITY modelled scenarios before the upgrades packages were investigated. The first upgrade to be modelled was for the ceiling. The ceiling insulation was upgraded to two layers of R-40 batt for a total effective R-Value of R68. The walls were modelled as double stud construction, each with R22 batt, and with exterior insulating sheathing for an effective R-Value of R40. Double wall construction is not popular in tract housing, however it was modelled because of the high R-Values that can be achieved; other alternatives exist to achieve high R-Values. The basement walls were modelled using a combination of insulating sheathing (2” extruded polystyrene) and R22 batt for an effective R-Value of R27. Extruded polystyrene at 2.5” thickness (R12) was provided under the entire basement slab. The windows were upgraded to triple glazing with two low ecoatings (e= 0.1), filled with krypton, and modelled with an insulated spacer. This window type represents a U-Value of 0.16 and a SHGC of 0.41. The air changes per hour (ACH)were reduced to 0.75. This level of air tightness has been demonstrated and achieved using the Owens Corning’s CodeBord Air Barrier System. All five tract builders participating in this ecoEII project will be using the CodeBord Air Barrier System as a standard in their net zero housing designs. The upgrades to the envelope accounted for an estimated 30% reduction in annual energy consumption. For the mechanicals, an 88% efficient HRV, a 96% AFUE furnace and a tankless water heater were modelled. A drain water heat recovery unit was modelled using the custom spreadsheet provided to the ecoEII project by Natural Resources Canada. The 120” unit has a 72% efficiency rating. The upgrades to the mechanical systems accounted for an estimated 20% reduction in annual energy consumption. In total, both envelope and mechanical system upgrades MICHAEL LIO AND CEARA ALLEN INDUSTRY NEWS Net Zero Housing Design Simulated – Case Study ISSUE 08 | WINTER 2014
  • 16. INDUSTRY NEWS 1414 resulted in an estimated 50% total reduction in annual energy consumption. The final scenario would require approximately 42,000 MJ of energy annually – a reduction of over 88,000 MJ from the Archetype House. Of the ten upgrades added to the model, the three upgrades that produced the greatest reductions were the R40 walls (8%), the triple glazed windows (8%), and the improved air tightness to 0.75 ACH (9%). While these are only scenarios, which do not provide information on the cost of these upgrades, and do not represent the final designs from the ecoEII builders, it does provide insights as builders consider the road to Net Zero. The five builders participating in the ecoEII Net Zero project - Construction Voyer (Laval, Quebec), Mattamy Homes Limited (Calgary, Alberta), Minto Communities (Ottawa, Ontario), Provident Development Inc. (Halifax, Nova Scotia), and Reid’s Heritage Homes (Guelph, Ontario) - have been under- taking similar exercises for each of their home designs over the last few months, using their HOT2000 outputs to modify and improve their Net Zero designs. The ecoEII builders each have very different housing forms. Each builder is designing a customized Net Zero package that is tailored to not only the housing forms, but also to the capacity of local trades, the local cost of labour and materials, and the local climate, among many other factors. Recently, the builders, consultants, and Owens Corning Canada, participated in the Net Zero North American Leadership Summit in Irvine, California. The regional teams presented their implementation plans including their designs,conservation measures, and energy generation strategies. They also presented the current challenges they are dealing with on their road to Net Zero. The presentations were well received by the summit participants, and generated a lively discussion. Construction of the Net Zero homes is expected to begin in the Spring of 2014, and will be completed by 2016. Funding for the project is being provided by the federal government’s ecoENERGY Innovation Initiative (ecoEII) program, Owens Corning, and in-kind contributions from the building industry. More information about can be found on the project website: http://www.zeroenergy.ca For more information on the project, please email Candice Luck, candice@buildABILITY.ca. TYPE UPGRADE ESTIMATED ANNUAL ENERGY CONSUMPTION (MJ)* % REDUCTION* Benchmark Ontario Archetype House 130,000 Base Loads Base Loads: reduced to new R-2000 levels 107,000 20% Envelope • Ceiling: R40 batt x 2, gypsum ceiling (=R68) • Walls: brick, air space, CodeBord, double stud with R22 batt x2, gypsum (=R40) • Basement Walls: concrete, CodeBord, R22 batt, gypsum + slab CodeBord (=R27 + R12) • Windows: U0.16 + SHGC 0.41 (triple glazed, 2 low e.1 coatings, 9mm krypton, insulating spacer, picture window, fibreglass frame) • Air Tightness ACH 0.75 66,000 30% Mechanical • DHW: tankless water heater EF.94 • DWHR from Spreadsheet • HRV @ 88% • Furnace AFUE @ 96% 42,000 20% *Numbers are approximations of simulated values It should be noted that that this is a case study done by buildABILITY; costs were not considered and this modelling is not representative of the final designs of the builders. The ecoEII builders each have different housing forms and customized net zero packages are being designed. MICHAEL LIO IS PRESIDENT OF BUILDABILITY CORPORATION, MICHAEL@BUILDABILITY.CA CEARA ALLEN IS MANAGER, TECHNICAL SERVICES, BUILDABILITY CORPORATION
  • 17. 17ISSUE 07 | FALL 2013 Features rHVCA ResidentialHeatingVentilation ContractorsAssociation rhvca.com | info@rhvca.com | 905-264-9967 heart The of your home Don’t leave the health of your home’s most valuable asset to chance. Trust only a RHVCA member to design, install and service your heating, cooling and ventilation system. Our members represent the highest standards of training, certification, and expertise in the HVAC industry.
  • 18. 16 One of the BestSteve Tobey Takes Us Back to School BY TRACY HANES
  • 19. 17 When the house at 296 Goodfellow Rd. in Codrington was destroyed by fire in January 2013, a couple not only lost their home. The local community lost a piece of its history. The century-old building in the Brighton area had originally been the one-room Mount Olivet Public School SS 25 that many local residents had attended as children. It was used as a school until 1967 when local centennial schools were built. The current owners, one a retired school teacher, bought the schoolhouse in 1985 and it became their personal home until the fire. A porch and addition were added to the original schoolhouse. While the fire left the exterior walls standing, it destroyed the inside of the house and its contents. “When the house burned, an icon of the community was gone,” says Stephen Tobey, Gordon Tobey Developments of Brighton, an award-winning builder. When his company was called on to design and build a replacement home for the site, the challenge was to honour the past while providing the homeowners with a modern new abode.
  • 20. 18 The house, called the Painted Maple, is 2,450 square feet, just slightly larger than the home it replaced. The design accommodates one-floor living for the retiree owners with master bedroom and ensuite on the main floor, with additional two bedrooms and bathroom in the loft above to accommodate their daughter-in-law and grandchild who come for extended stays. The kitchen, dining area and great room combine to form an airy, spacious single open living space. The great room and front entry hall have high ceilings open to the loft cat walk above. The main floor also includes a den/office and a large mud room that is close to the detached garage. The front of the home features symmetrical proportions, a large covered porch, a steep gable over the front door, ginger- bread trim and black shutters. The red brick has Flemish bond detail reminiscent of the red brick from the schoolhouse. The original bell from the school was salvaged and mounted on a structure on a corner at the front of the lot. The last teacher to teach at the school lives in a farm across the road and remembers ringing the bell at lunchtime for the children, that also served as a signal to local farmers in their fields that it was time to stop work and break for food. “The property had mature trees, a driveway and pool and we put the new house where the old schoolhouse had been,” says Tobey. “But the old schoolhouse didn’t have views where views should have been.” Now, low-E argon windows that minimize heat loss in winter and heat gain in summer allow for generous natural light and provide views of the surrounding fields and the pool. The windows are single and double-hung styles chosen for their traditional appearance. The homeowners had lived with a leaky building envelope and had only a crawlspace with dirt floor under their school- house home. Their energy bills had been steep, so a priority was comfort and energy efficiency for the replacement home. As an R2000 builder, Tobey knew his company could deliver the quality, design and superior energy efficiency the home- owners required. The new home was built to Energy Star standard and well above Code. Because his company provides a comprehensive energy package to its clients, Tobey says that freed the homeowners from having to make even more choices. “They had to make so many decisions and it can be overwhelming. By using us “We wanted the new house to pay homage to the style of the old schoolhouse and fit into the local agricultural community,” says Tobey. “We decided on a home similar in style to a traditional Ontario farmhouse style. But inside, the homeowners wanted a modern, open-concept layout.”
  • 21. Discover the Difference—experience our customer focused building process that fosters confidence and peace of mind. www.tobeydevelopments.com 613 475 0618 Brighton.On LIVE YOUR DREAM
  • 22. 20 as designers and builders, we can give them the energy package and say ‘this is what you’re getting,' which is a bonus for them.” The Painted Maple was not built to R2000 specifications although Tobey Developments has built many homes to those criteria. In January 2014, R2000 buildings will be required to be 50 percent more energy efficient than Code-built ones, with a building envelope 25 percent tighter. The best-in-class standards will address air conditioning, micro-power generation, solar thermal, etc. which will add significant cost for the home buyer. Tobey is not certain his company will pursue the new R2000 for its homes, though the company will continue to provide the same high level of energy efficiency and quality construction methods as it has been. Tobey’s building his own house to the new R2000 criteria “to see what we think of the whole thing” and to determine whether it will justify the added expense to achieve the stringent new benchmark – and if it’s something customers are willing to pay for. The Goodfellow Rd. home’s HVAC system includes a high efficiency propane furnace and Energy Recovery Ventilator with DC motors, and a 15 SEER air conditioner to reduce consumption of electricity. All lighting uses Energy Star certified bulbs. The tightly sealed building envelope boasts superior tightness and insulation, windows are low E argon and the basement has under-slab foam insulation. In third party tests, the home achieved a HERS score of 41 and an EnerGuide score of 84. FEATURE STORY
  • 23. 21ISSUE 08 | WINTER 2014 TRACY HANES IS A FREELANCE FEATURE WRITER FOR THE LARGEST DAILY NEWSPAPER IN CANADA AND SEVERAL MAGAZINES. WWW.TRACYHANES. This house is rated using the Home Energy Rating System (HERS), property of RESNET of Oceanside, CA. * Cost of Natural Gas for Space and Hot Water IECC OBC-12 110 100 90 80 70 60 50 40 30 20 10 0 John Godden October 22, 2013 Built by: Gordon Tobey Developments Ltd. Address: 296 Goodfellow Rd., Brighton, ON Rated by: Clearsphere Consulting Rating Conducted: Oct. 22nd, 2013 41 THIS HOME EXCEEDS THE ONTARIO BUILDING CODE 2012 BY 34% Hardwood flooring used in the home is FSC certified. The homeowners like the look of natural wood and their furniture is a mix of Mission-style pieces and antique replicas. Materials chosen for the home, in keeping with the charm of the old schoolhouse, include stained wood cabinets, oak flooring, stairs and railings, whitewashed pine kitchen and dining room ceilings, and a propane stove designed to look like a traditional wood- stove. The master ensuite, with all the comforts of a modern bathroom, has a claw-foot tub reminiscent of a traditional cast iron tub. The large kitchen boasts ceiling-height cabinets to provide plenty of storage and is equipped with a built-in recycling centre. Though the fire was an unexpected and unwelcome event that meant the loss of a beloved heritage building and their possessions, the homeowners can now look to their future. Their new house was completed in October and they are enjoying a space that was specifically designed to accommodate their love for entertaining and the day-to-day living needs of their multi-generational family in warm, comfortable surroundings - without the costly energy bills. FEATURE STORY BUILDER STEVE TOBEY AND PROUD HOMEOWNERS DOUG GOWER AND ALICE ABBOTT “How much more energy efficient should we build homes?” As a builder one of the most satisfy- ing feelings is to close a new energy certified home with a buyer who feels that they have received real value. Value both in terms of their initial investment and their future energy savings. Be- ing the builder, I specify the extent of energy features installed in the home. Spending Ten to Twenty Thousand Dollars to save a couple Hundred bucks per year will simply leave your buyer/ potential buyer feeling cold. Achieving long term value in your home is what we do best. Cur- rently building my own home I want a label that reflects all the energy features that are built in. My projected as-built HERS score is 37 which is 40% better than code. Stephen Tobey – Builder
  • 24. BUILDER NEWS 22 Seeing as custom homebuilder Amedeo Barbini used to play trumpet professionally, it’s tempting to draw on musical metaphors to describe his approach to house construction. But by orchestrating every aspect from the green core to the aesthetically pleasing envelope, he is able to create something lasting and beautiful that also appears effortless, like say something you’d experience at Roy Thompson Hall -- or the Rex Hotel if you’re a jazz enthusiast. But enough of the musical metaphors. Now into his fourth decade of custom-home building, Barbini begins each home with intensive research, carefully investigating the mechanics that will produce energy efficiency, excellent interior air quality, and consistent heat and cooling throughout the entire space. He then designs spaces with views to the exterior in mind, and pursues the finishes and materials that will result in a distinct aesthetic. The home he is just completing was purchased at the end of 2012, a sturdy 1950s brick ranch typical of the homes built in Don Mills, a progressive subdivision development for its day. The neighbourhood’s larger than average lots have made it a target for more recent renovators and new home builders looking to build larger than average homes. In this case, the 9200 sq. ft. lot allowed for a 5000 sq. ft. home. Given city bylaw restrictions though, Barbini had to retain 50% of the existing walls, prompting construction of the new house around the old. This inadvertently served a green purpose – the remaining brick walls provided an additional eight inches of insulation. Where there isn’t any masonry, walls consist of 2x6 studs with an R value of 22, covered by half-inch plywood and then two inches of Styrofoam before applying the exterior stucco. Fortunately, the original footprint was also conducive to the contemporary style Barbini envisioned for the home, by adding four small “wings” that kept them well within the allowable gross floor area, and adding a second storey that is stepped back so as not to overpower the lot. The handsome façade in charcoal grey Belgian brick – chosen for its precision lines and consistent thickness – and clear 1x6 tongue-in-groove Western Cedar slats, has equally attractive guts that have built-in future proofing qualities. The new HVAC system has been designed to reduce energy use and be a hedge against steadily rising energy costs, but also to create a consistent and comfortable interior air quality. The original basement was left untouched structurally – no need for digging down since the ceilings were sufficiently high at 7.5 feet – and all Barbini did was tuck the high velocity ductwork inside the ceiling (that’s the only way you can do it) to make a clean space without bulkheads. (Note: High velocity ducts are the only ones capable of being tucked inside the ceiling joists.) The original basement, which doesn’t extend under the entire new structure, has a built-in energy reducer in the crawlspace that extends over 1500 sq. ft. At a depth of 30 inches, this crawl space conditions the living space above. If you think about how cold the floor of a room gets above a garage, no matter how much or what kind of insulation is used, you’ll get the idea. The crawl space was created with six inches of gravel poured at ground level, then overlaid with an R10 Insultarp insulation blanket followed by two inches of Roxul and topped in plywood to create a floor should anyone need to get into the crawl space. Stepping back the second storey had another design benefit of allowing for some unique light transfer within the home. All the Glazing area has been placed at the rear of the house to capture the magnificent treed view – with the massive pivoting glass doors off the main floor living room it feels like being in the Muskoka woods. At the front of the house, Barbini has placed the bedrooms – a master suite on the main floor and other bedrooms and baths on the second floor. Each bedroom has wide, short windows positioned close to the ceiling line – these allow plenty of daylight to flood the spaces without compromising privacy. An overhang at the roof line over each of the smaller windows further filters light, cutting back on glare and heat and thus going easier on the HVAC – and thermostats. Large windows tend to register higher or lower temperatures adjacent to the glass, thereby triggering the on and off of air conditioning or heat, leaving the space further The Best Way to Renovate INTEGRATING THE PAST, PRESENT AND FUTURE ALEX NEWMAN
  • 25. Air.Vapour.Water. Ice Nothing gets past Henry. ® Air and Vapour Barrier Waterproofing Roofing Protecting properties – and reputations – for decades Henry’s Building Envelope Systems® provide industry-leading protection from uncontrolled air, vapour and moisture, from foundation to roof. Proven effective in the challenging winters of Canada, our air and vapour barriers, waterproofing and roofing products protect properties from the elements to save energy, prevent damage, extend building life, and create more comfortable and healthy indoor environments. BlueskinVP ® This fully adhered membrane functions not only as a water-resistant barrier and rain barrier, but stops uncontrolled air leakage. performance longevity Blueskin ® WB Seal out air and moisture, and seal in energy and comfort with this self- adhered window and door flashing. infiltration and water damage Blueskin ® WP200 The first choice in sheet applied waterproofing, this self-adhered waterproofing membrane is designed for prepared concrete or masonry substrates, providing a waterproofing barrier for below grade use. lateral water movement increased protection at overlaps www.henrycom Blueskin ® ROOF RF200/RF200LT A self-adhered ice and water barrier,speciallydesignedfor slopedroofsurfacestoprovidea secondaryseal under shingles or tiles. temperature underlayment polyethylene film fasteners Eaveguard Self-Adhered Shingle Underlayment helps prevent leaks from wind-driven rain and ice damming. asphalt and glass fiber mat slip-resistant working surface for ease of application
  • 26. BUILDER NEWS 24 inside the home at the mercy of the fluctuating temperature levels. All the windows are manufactured by Inline Fiberglass Ltd. They are thin-walled fibreglass windows inserted directly into the walls without exterior moldings or trim, which makes for a cleaner profile and once caulked a tighter seal. The fibreglass guarantees maximum heat retention, losing nothing from the glass to the outdoor air. Barbini also opted for increased volume with 11- foot ceilings on the main floor, except for the ten-feet in the main floor master wing, and nine feet on the second floor. This increases air- flow and visually expands the space. When it came to running the home’s heating and cooling, Barbini opted for a two zone system – with two high velocity Airmax air handlers (because of the home’s large volume and footprint) and a condensing boiler, two copper drain water heat recovery (DWHR) pipes and the Flowmax indirect hot water tank which acts like a “battery” for the radiant floor system. Domestic hot water comes from the Flowmax tank, but also stores heat for the radiant floors so that the condensing boiler doesn’t have to cycle on and off, which is not a good thing. There’s also an energy recovery ventilator for fresh air circulation. This is such serious HVAC equipment that it’s been divided between two furnace “rooms” -- two air handlers, DWHR pipes, and the Flowmax water heater in one, and the gas-powered boiler, and orange flex pipes filled with water for the radiant floor heat in the other. With first and second floors in different zones, in terms of HVAC, Barbini was able to direct more air conditioning to the second floor. “Here’s a renovator who believes in the idea of building the value of future proofing into his home, so that on the back end he can differentiate himself,” says John Godden, with whom Barbini consulted several times about the HVAC system. “It’s a difficult market, because this is not a brand new house, so he’s doing all the things he needs to that makes it better than the new build. With the extent he’s gone to he will have a HERS score below 50. This score is as good as you can get on new housing without renewables.” The system isn’t as complicated as it sounds, but it does require mechanical expertise to install. In one of the many consults Barbini had with Godden and the Clearsphere team, the one mechanical contractor whose name came up repeatedly was Branko Mijatovic (Alpha Comfort and Control http://www.alphacomfortcontrol.com/). “You really need a skilled HVAC contractor who really understands this kind of system,” says Godden. “Especially in a project like this, when you have different interior ceiling heights, and you’re aiming to create two This house is rated using the Home Energy Rating System (HERS), property of RESNET of Oceanside, CA. * Cost of Natural Gas for Space and Hot Water IECC OBC-12 110 100 90 80 70 60 50 40 30 20 10 0 John Godden November 27, 2013 Built by: Amedeo Barbini Address: 61 Talwood DR, Toronto, ON Rated by: Clearsphere Consulting Rating Conducted: Nov. 27th , 2013 49 THIS HOME EXCEEDS THE ONTARIO BUILDING CODE 2012 BY 26% WINDOW DESIGN MAXIMIZES NATURAL LIGHT AND PRIVACY
  • 27. ISSUE 07 | FALL 2013 different zones in order to future proof against rising energy costs. It’s important to have a very good mechanical contractor, who can match equipment to the needs of each individual home.” Also located in the second furnace area are the sump pump and the sewage pump. Because North York is lower than the city’s drains by a foot, every house in the area has a sump pump and a sewage pump for better drainage. The sewage pump takes the drain water from the laundry room and base- ment bathroom, while water from the rest of the house is car- ried away by the stack. Honeywell contributed state of the art controllable thermostats to the house. This central control manages, heating, cooling as well as humidification and central ventilation through a energy recovery ERV. The ERV manages both, humidity in summer and winter, but these are not your usual control panels. Wi-Fi compatible, the controls can be carried remotely into any room in the house so that temperatures can be controlled from anywhere. If the bedroom is too cool, and you only want to raise the temperature there, you can take the remote and increase the heat in that room only, Barbini explains. “This isn’t only about being able to control the environment for comfort,” he says, “but also about economics. No sense wasting heat in areas you are not using.” The new home, which Barbini expects to market in the spring, is a good example of an integrated design process. That is, in simplest terms, integrating the design of a beautiful home with the design of its beautiful mechanics, which results in space that is aesthetically pleasing, and comfortable. These future proofing efforts will pay off for the new owners of his home in much lower gas and electricity bills. Barbini goes to such lengths with materials, finishes and systems because he wants his houses to last, to be gentle on the environment, and to garner lower heating and cooling bills. Most builders will only go to such lengths when already working for a client with imagination and deep pockets, but Barbini is prepared to gamble that the end user – in this case the buyer of this modern Don Mills home – will recognize its hidden, as well as overt qualities. BUILDER NEWS ALEX NEWMAN IS A WRITER, EDITOR AND RESEARCHER AT WWW.INTEGRITYCOMMUNICATIONS.CA ISSUE 08 | WINTER 2014 25 ALSOAVAILABLE INR9&R11 Introducing Amdry, the only insulated channels. C onnecter System
  • 28. BUILDER NEWS The Best Way to Insulate Basement Floors When it comes to reducing energy consumption within the home there are many factors to consider; the most critical of which is insulation. Creating a tight and efficient envelope begins with the systems and products builders use, and given the recent changes to the Ontario Building code, insulation and its importance to the homeowner has never been as significant a topic. Amvic Building system, a Canadian based insulation manufacturer, has once again raised the bar with its two most recent products; the Silverboard SB35-UC board and PEX Radiant Heat Insulating Panels. Updates to the SB12 building code now mandate that all concrete slabs containing radiant heat piping must have a minimum R10 insulation under the slab; the SB35-UC not only meets this requirement, but also provides vapour, radiant and radon barriers. Silverboard SB35-UC was specifically designed for on or below grade insulation applications. It also offers a flexibility (84 Psi) and load compression toughness (35 Psi) not found in traditional flat-sheet EPS or fibreglass boards, which not only increases job-site efficiency by enabling workers to walk and drive over it, but also minimizes waste. Peter Voong, of Castle Form Homes, says the Silverboard SB35- UC is an unparalleled product, “When it comes to insulating radiant floor heating - the most efficient method for heating your house - this product is the superior choice for insulation.” In his most recent LEED build Voong used the SB35-UC under the basement slab and walkout, “It was really easy to install...simple and light-weight, a very cost-effective and versatile product.” The reflective laminated surfaces not only reflect radiant energy (keeping heat outdoors during the summer and containing it inside during the winter), it also provides a continual barrier that protects the core from air and moisture for longer life. Silverboard SB35-UC is available in 4’x8’ sections and can be found at a variety of hardware and home building stores. The Insulated Radiant PEX panel is another Amvic product that strives to improve upon installation and performance characteristics for Hydronic radiant floor heating systems. While Silverboard is attached to a mesh screen that sits on the piping, PEX panels were designed to create non-contact voids. The combination of expanded polystyrene (EPS) insulation, one of the highest performing, energy efficient insulation materials available today, vacuum moulded to a high impact reinforcing HOWARD COHEN AND BETTER BUILDER STAFF 26
  • 29. BUILDER NEWS 27 and VB polystyrene film makes for a strong resilient interlocking PEX panel. The reverse tapered, raised nubs form a “mushroom” shape to lock the PEX piping firmly in place once installed - also allowing the panel to accept 3/8” to 1” pipe diameters (more than any other panel on the market). The PEX piping is easily inserted into the panel simply by walking on the tube. Once inserted the pipe will be properly positioned and seated on the panel. The innovative patented design ensures that the tube will be completely surrounded by concrete and not resting on the bottom face of the panel as some competitive products do. This allows for the proper heat distribution of the radiant tubing and more efficient energy transfer. ISSUE 08 | WINTER 2014 HOWARD COHEN, DIVERSIFIED INSULATION PRODUCTS MANAGER, AMVIC HOWARD COHEN, DIVERSIFIED INSULATION PRODUCTS MANAGER, AMVIC 2 INCH SILVERBOARD R10 INSULATION PLUS A RADIANT BARRIER - THE BEST WAY TO INSULATE
  • 30. BUILDER NEWS 28 Doug Tarry Homes recently opened our latest model home, the Edenbrook, during the first week of October. Today, as an industry, builders open new model home centres all the time, and while we are always proud to show off our newest creations, there are the rare exceptions when something truly revolutionary is presented to the marketplace. Such is the case with this Discovery Home built as part of our commitment to the Union Gas Optimum Home Program. Through the Optimum Home Program, we have been able to work closely with a number of building science experts and consultants to help us address some critical next steps in the construction of high-performance homes. In this particular home we are demonstrating two new technological features that will have a significant impact on the building code and how homes are built in the future. The first is the pilot project we are conducting with Dettson Industries on right sized furnaces. The F280 guidelines, that mechanical designers use to size their equipment, do not properly account for the tighter homes that the current Ontario Building Code and energy programs such as Energy Star are requiring of builders. This, combined with furnace manufacturers not recognizing the need for smaller HVAC equipment, is leading to performance issues in our homes. Issues such as temperature differences and comfort complaints. An updated F280 will be an alternative option under the new 2012 OBC, starting in January. Using the new F280 will see furnace size requirements drop significantly. Doug Tarry Homes has been working on this sizing issue for several years. What we have found is that under the old F280 a furnace might be sized at 45,000 or even 60,000 BTU's of heat output, but might only need to be 28-30,000 BTU's on the coldest day of the year. The challenge with the new sizing requirements that we should be using is that there are no furnaces available that perform between 12-30,000 BTU's, which is what we need. Regrettably manufacturers seem to be fairly ambivalent to our needs. This is where Dettson Industries comes into the picture. This Canadian owned furnace manufacturer, based in Quebec, has recognized that there is a need for right sized furnaces. I was put in touch with Marc Chenier from Dettson through our involvement in the Union Gas Optimum Home Program. Back in March I had the opportunity to visit the test lab near Montreal and check out the product they were planning to manufacture. What I was most impressed about was not only the willingness of the Dettson engineers to listen to our performance concerns but that they understood the need for smaller, right sized, high performance furnaces. After some very positive conversations we agreed to provide Dettson industries with two homes to test their right sized furnaces in. On October 3rd we had the privilege of unveiling the new Dettson Chinook prototype furnace. The Chinook is fully modulating with an ECM motor and has a BTU output range between 12,000 to 30,000 BTU's, which matches our homes needs. It is currently available for viewing in our Discovery Home in St. Thomas, where we are testing the prototype over the next twelve months. Dettson is projecting that the BTU Chinook will be available in the market by February. Builders who are constructing MURBS will be interested to know that Dettson is also working on a 15,000 BTU furnace they hope to bring to market in the spring. Of course none of the right sizing of furnaces project would have been possible without the understanding and support of our former Chief Building Official, Leon Bach, who understands the performance issues and permitted us to design the system to the new F280 Standard as an alternative compliance solution even though the new Standard does not become an option until January 2014. We are very appreciative of Leon’s support and the other building officials involved with our Discovery Home that helped to make this project a reality. The other pilot project featured in our Discovery Home is a new basement wall system that we call the Optimum Basement Wall. I've previously written about our journey to a better basement wall and our work with ROXUL. My next article will focus on the Optimum Basement Wall. DOUG TARRY DOUG TARRY JR., IS THE DIRECTOR OF MARKETING AT DOUG TARRY HOMES IN ST. THOMAS , ONTARIO. The Best New Demo Project THE OPTIMUM HOME WITH THE OPTIMIZED HVAC SYSTEM
  • 31. BUILDER NEWS ELECTRICAL DATA WEIGHT 75K 105K 120K lb / kg 114 / 51,7 138 / 62,6 146 / 66,2 Supply 115 Volts - 60 Hertz - 1 Phase Maximum consumption From 10,53 to 16,19 Amps 40 VA www.dettson.ca WARM AIR GAS FURNACE DESIGNED, ENGINEERED, AND MANUFACTURED IN CANADA FOR HEATING AND COOLING CANADIAN RESIDENCES Benefits and differentiators Product line features - Single stage Product release schedule Phase I - Phase II - Phase III - 15 K 34,29 31,75 31,75 33,02 x 60,96 30 K 34,29 31,75 31,75 33,02 x 60,96 45 K 34,29 31,75 31,75 33,02 x 60,96 60 K 40 37,46 36,83 38,1 x 60,96 75 K 40 37,46 36,83 38,1 x 60,96 105 K 53,34 50,80 41,91 43,18 x 60,96 120 K 53,34 50,80 41,91 43,18 x 60,96 15 k 13 1/2 12 1/2 12 1/2 13 x 24 30 k 13 1/2 12 1/2 12 1/2 13 x 24 45 k 13 1/2 12 1/2 12 1/2 13 x 24 60 k 15 3/4 14 3/4 14 1/2 15 x 24 75 k 15 3/4 14 3/4 14 1/2 15 x 24 105 k 21 20 16 1/2 17 x 24 120 k 21 20 16 1/2 17 x 24 DIMENSIONS (inches) DIMENSIONS ( ) Furnace size Filter Size A Cabinet width B Supply duct width C Return duct width Furnace size Filter Size A Cabinet width B Supply duct width C Return duct width 19.08 8.54 0 2.50 5.03 B Supply duct width A 15.71 33.57 6.76 29,02 24,00 1.09 1.03 6.05 2.66 2.26 0 0.88 2.00 C Returnductheight Return duct width
  • 32. BUILDER NEWS BP Excel breaks new ground in structural insulation thanks to a membrane that combines air barrier protec- tion, moisture-evacuating breathability, and strength like no other product. And it’s green — made from 98% recycled materials, free of VOCs and ozone-depleting CFCs or HCFCs, and glued together with wheat starch. For homebuilders looking for innovation and value on an exponential scale: Excel is innovative green design, exceptional thermal insulation and structural strength all in one breathable sheathing that delivers outstanding performance with unparalleled strength. www.bpcan.com WELCOME TO STRUCTURAL INSULATION REINVENTED FOR TODAY’S WORLD — AND A SUSTAINABLE TOMORROW. MADE HERE PREFERRED EVERYWHERE NEW!
  • 33. 31 BUILDER NEWS Reliable, customized, maRtinoHeating • air conditioning • indoor air Quality • HVac design 1-800-465-5700 ™ www.martinohvac.com The ARGILE Project: BUILDING SCIENCE RESEARCH AT GEORGE BROWN COLLEGE ARGILE'S vision is to research and develop optimal systems of materials and methods for the retrofitting of existing vintage solid masonry buildings, with the objectives of improving their energy efficiency, durability and occupant health. The International Energy Agency emphasizes the need for better building practices by stating "... existing buildings are responsible for over 40% of the world's total primary energy consumption" (IEA, 2008). It has thus become clear to our research team that increasing the energy efficiency of buildings is a vital step we must take to ensure energy security and environmental damage is minimized for our future generations. Although the aim to investigate the cost/benefit of retrofitting vintage buildings and to establish a link between vintage building retrofits and "sustainability" represents the main focus of ARGILE, there is a need for advanced contractors to push the envelope, set new standards, and surpass the THE ARGILE RESEARCH TEAM ISSUE 08 | WINTER 2014
  • 34. BUILDER NEWS 32 requirements of the Ontario Building Code for new construction in homes. The "Optimum Basement Wall" designed by Doug Tarry Custom Homes Ltd. functions to mitigate condensation build up within the basement wall assembly. According to Doug Tarry Jr.: "Consumers today expect their basements to be as usable as their above grade floor space, but the conditions are completely different. We realized that the current building code is leading to far too many basements with mould and moisture issues. The problem is the vapour diffusion in the wall. Clients don't understand that this vapour flow is a natural occurrence and that most basements will have issues with vapour flow that will frequently lead to mould." The ARGILE research team has partnered with industry leader, ROXUL® and progressive contractor, Doug Tarry Custom Homes Ltd. to study their show home in St. Thomas, ON. Our research aims to verify the field performance of their basement insulation system by utilizing innovative technology to remotely collect data for evaluation. The wall system features the use of CertainTeed's "MemBrain", which replaces the top third of the polyethelyene sheeting used in the assembly. This polyamide-based material has the ability to adapt it's permeability with changing climatic conditions. As relative humidity increases, it's water vapor permeability increases, and during low humidity conditions, it's permeability will decrease to resist water vapor permeability. This provides the potential to dry out condensation that would normally collect behind the polyethylene and lead to mould growth. The use of the ROXUL® Comfortboard IS layer is also critical. Since stone wool is water repellent, it will allow any liquid water that may enter into the assembly to drain down its surface to the footing instead of being wicked into the insulation. ARGILE Research's in-house team has developed temperature, moisture content, and relative humidity sensors which have been installed at critical points within the wall assembly, as well as in the below grade soil. The data logging systems have been programmed to translate data remotely for analysis. The information captured by the system will be analyzed for a full heating and cooling cycle to assess the durability and performance of the “Optimum Basement Wall”. THE ARGILE RESEARCH TEAM: P. CHRISTOPHER TIMUSK (PRINCIPAL INVESTIGATOR) | STEFFANIE ADAMS (CO-INVESTIGATOR) | ANDREW FRASER (CO-INVESTIGATOR) ALEXIS RODZIEWICZ (PROJECT MANAGER) | ARIZONA DIXON (STUDENT RESEARCHER) OPTIMUM BASEMENT WALL - MONITORING ROXUL PERFORMANCE MARC BUCKLEY - RESEARCH WITH GEORGE BROWN
  • 35. ISSUE 07 | FALL 2013 BUILDER NEWS 33 ] Solar Ready It’s fitting that this edition is dedicated to future proofing. This is a concept that I have been discussing and designing into my homes for many years. Why? Be- cause I believe that rising energy costs over the next generation will continue to make energy efficiency a greater priority for our consumers. As an industry, we continue to build ever more energy efficient homes. However, there is one major challenge that we face: our customers! Don’t get me wrong, I am grateful for all of my customers and I hope to build for many more. It’s just that today’s consumer is much more demanding than even a few years ago. They want longer showers with multiple showerheads just like they see on the TV shows; they want their home to be uniformly cool all summer, even with that big bank of windows facing the sun. The expecta- tion of performance is that their utility bill will go down, or at least not change, even though they continue to use their personal car wash (that’s what I call the full body wash shower) and run that AC right through the day. At some point in our customers’ future their thoughts will change from conserva- tion to generation. That’s where future proofing comes in. So I thought I’d share my insights on Solar Ready, the ultimate future proofing for the homes we build. In 2007, Doug Tarry Homes was contracted by Natural Resources Canada to conduct the Solar Ready pilot project. This included writing the first Solar Ready technical specifications. Since 2007, we have continued to build all of our homes with Solar Ready design as a standard feature. In that time we have also installed several solar thermal water heating systems. In October 2012, NRCan published the revised Solar Ready Specifica- tions. So here’s the good news. Solar Ready is fairly easy and inexpensive to include in a home provided you put some thought into it during the design process. OK, so two storey homes can be a bit harder because of the popularity of open concept main floors even on two storey homes. It has been our experience that it costs an additional $350-$450 per home for the Solar Ready rough in. SO WHAT IS A SOLAR READY HOME? There are two key components. First, space on the roof at a viable solar angle, and second, a conduit from mechanical room to accessible attic space. Roof orientation for solar installations is considered viable from Southeast around to West for solar thermal systems. South is most efficient for Photo Voltaic systems. Here are some important points to remember: • The solar conduit needs to run from the mechanical room to the attic. I prefer to install two – 2” conduits, rather than one 4”. If you ever have to bend the conduit slightly, there is no give in the 4”. Also the 4” requires a 2x6 wall which may not be otherwise necessary for the home. • It is important to avoid plumbing or mechanical runs in the dedicated location of the conduit, or it may be almost impos- sible to find later on. Whatever conduit type you choose, it is important that they be capped at both the top and bot- tom, otherwise you can have a condensation loop into your attic as well as a fire chase. I don’t trust tape as the glue will diminish over time. • Location of the future solar hot water tank should be shown on the basement plan so that the appropriate amount of space is available. It is also good practice to show the roof elevation that the panels are intended to be installed on, so that there • It is not a requirement, but it is a recommended best practice that the trusses intended to carry the solar panels be designed and built with an additional 5 lb. dead load to account for the additional weight. • Installation of panels should not be directly into the top chord of the truss. Rather it is better practice to attach scab lumber to the side of the top chord and attach into the scab. • The existing Domestic Hot Water Heater needs to have plumbing valves and “T”s installed and an electrical outlet needs to be located beside the unit. This is to permit quick connection at the time of installation. Fire Resistant Water Repellent Sound Absorbent Saves Energy Made from Stone Recycled Content TM HIGH R ECYCLED CO N TENT *Contact us for details. HIGH R ECYCLED CO N TENT R E C Y C L A B L E* Achieving an R-20 Basement Wall “IS” Easy with Roxul ComfortBoard™ IS. ■ Prevent Thermal Bridging: Installing ComfortBoard™ IS against the foundation wall before you frame the studs provides for a continual layer of thermal protection. ■ Non Combustible: Provides for combined thermal and fire-resistant properties. ■ High Recycled Content: Made from natural stone and up to 93% recycled material. INTERIOR BASEMENT WALL APPLICATION BY ROXUL® www.roxul.com ComfortBoard™ IS is a trademark of Roxul Inc. GREENGUARD® is a registered trademark of Greenguard Environmental Institute. ROX-2410_0712
  • 36. BUILDER NEWS 34 PAGE TITLE Features To learn more, visit www.savingsbydesign.ca TM Helping builders design and build more energy efficient homes. New building codes require new approaches to housing design and energy performance. Enbridge’s Savings by Design program is here to help. The program offers free access to design and technical experts, as well as valuable incentives to help design and build more energy efficient homes. Using our unique and collaborative Integrated Design Process (IDP), we will work with you to identify optimal solutions for improving energy efficiency 25% beyond Ontario Building Code 2012.