Differential / Pressure Transmitter
/
Gauge/Absolute Pressure Transmitter
Differential Pressure Level Transmitter
Remote Seal Differential Pressure Transmitter
Remote Seal Gauge/Absolute Pressure Transmitter
Silicon Sensor Type Transmitter Catalogue
EJC Smart Pressure Transmitter Product Overview
www.bcstgroup.com A1 BCST Group C.,Ltd
Contents
1 Technical Background…………………………………………………………………………A2
2 Principle of Operation…………………………………………………………………………A3
3 Main Specification………………………………………………………………………………A3
4 Product Overview………………………………………………………………………………A4
5 EJCDP-A High Performance Differential Pressure Transmitter ………………………1
6 EJCBP-A High Performance Gauge/Absolute Pressure Transmitter ………………7
7 EJCDP-B/C Differential Pressure Transmitter……………………………………………14
8 EJCBP/A-B/C Gauge/Absolute Pressure Transmitter……………………………………21
9 EJCDM Micro-Differential Pressure Transmitter …………………………………………27
10 EJCLT Differential Pressure Level Transmitter …………………………………………33
11 EJCRHL Remote Seal Differential Pressure Transmitter………………………………39
12 EJCRNS Remote Seal Gauge/Absolute Pressure Transmitter ……………………48
13 EJCBP/A-S Sanitary Gauge/Absolute Pressure Transmitter …………………64
14 EJCBP/A-S Sanitary Gauge/Absolute Pressure Transmitter ……………………73
15 EJCDP-S Sanitary Remote Seal Differential Pressure Transmitter …………………80
16 EJCMT Multi Variable Pressure Transmitter………………………………………………87
EJC Smart Pressure Transmitter Product Overview
www.bcstgroup.com A2 BCST Group C.,Ltd
Technical background
BCST Group Co.,Ltd, with solid and strong technical
background, has close cooperation with several famous
research institutes and groups in Europe (such as EPFL, IMT
of University of Neuchatel, CESM).The research
achievements transfer rate is over 93%. It also retains good
cooperation relationship with several world leading sensor,
instruments & meters, automation equipment,
micro-electronics and micromechanics corporations in Europe.
Jiangsu BCST Group Co.,Ltd is granted by BCST Group
Co.,Ltd the complete authorization for its world leading core
sensing technology and production-manufacturing techniques
of pressure instruments & meters.
BCST supply one step solution for
pressure transmitter
EJC Smart Pressure Transmitter Product Overview
www.bcstgroup.com A3 BCST Group C.,Ltd
Principle of Operation
EJCDP Differential Pressure Transmitter
The differential pressure transmitter includes two
functional units:
—Main unit
—Auxiliary Unit
The main unit includes a sensor and process
connection. The completely welded sensor module is a
twin-chamber system with an integral overload
diaphragm, an absolute pressure sensor, a
temperature sensor and the silicon differential pressure
sensor. The absolute pressure sensor, which is only
exposed to the pressure at the high pressure side, acts
as a reference value to compensate for the static
pressure. The temperature sensor as a temperature
compensated reference value to compensate for the
temperature drift.
RP1002/3 Gauge/Absolute Pressure
Transmitter
The gauge/absolute pressure transmitter includes two
functional units:
—Main unit
—Auxiliary Unit
The main unit includes gauge/absolute/temperature
sensors and process connection. The low pressure
span completely welded sensor module is a
twin-chamber system with an integral overload
diaphragm, and a silicon pressure sensor. The
temperature sensor as a temperature compensated
reference value to compensate for the temperature
drift.
Main Specification
 The differential pressure transmitter utilize the
world's leading high stability silicon sensor, the
highest Reference Accuracy is ±0.05%;
 Micro-differential pressure transmitter utilize the
world's leading dual overload diaphragm patented
technology, the highest Reference Accuracy is
±0.075%;
 The differential pressure transmitter working
pressure are 16 MPa, 25 MPa and 40MPa, the
one-way overload pressure up to 40MPa;
 The absolute pressure sensor packaged in the
differential pressure transmitter, can be used for
static pressure measurement, display , and the
static pressure compensation. The minimum of
the static error is ≤±0.05 %/10MPa;
 High sensitivity temperature sensor packaged in
the sensor. The minimum of the temperature error
is ≤±0.04 %/10K;
 Stainless steel 316L and silicone oil filling welded
seal structure;
 Micro-pressure / absolute pressure transmitter
utilize the no pressure transmission loss overload
diaphragm patented technology , the one-way
overload pressure up to 7MPa;
 Long stability is ≤±0.1%/3years, 10 years of
maintenance-free;
 Extremely wide measuring range 100Pa~60MPa;
 Adjustable up to 100:1 range ability;
 The remote seal transmitter utilize ultra-high
temperature(400℃) patented technology.
EJC Smart Pressure Transmitter Product Overview
www.bcstgroup.com A4 BCST Group C.,Ltd
Product Overview
1 EJCDP-A/B/C/D Differential Pressure
Transmitter
 Measurement medium: gas, steam, liquid
 Range Limits: 0—100Pa~3MPa
 Accuracy:±0.05%、±0.075%、±0.1%、±0.25%
 Isolating Diaphragm:316L / Hastelloy C / Gold
plated on 316L / FEP plated on 316L / Tantalum
2 EJCBP-A/B/C Gauge Pressure
Transmitter
EJCBA-A/B/C Absolute Pressure
Transmitter
 Measurement medium: gas, steam, liquid
 Range Limits: 0—600Pa~40MPa
 Accuracy:±0.05%、±0.075%、±0.1%、±0.25%
 Isolating Diaphragm:316L / Hastelloy C
3 EJCLT Differential Pressure Level
Transmitter
 Suitable for measuring the fluid medium of high
temperature, high viscosity, corrosive, easy to
precipitate
 Range Limits:0—1kPa~3MPa
 Fill fluid: silicone oil, vegetable oil
 Isolating Diaphragm:316L / Hastelloy C / Gold
plated on 316L / FEP or PFA plated on 316L /
Tantalum
4 EJC Differential Pressure Remote
Seal Transmitter
 Suitable for measuring the fluid medium of the
high temperature 400 ℃,high viscosity, corrosive,
easy to precipitation
 Range Limits:0—1kPa~3MPa
 Fill fluid: silicone oil, high temperature silicone oil,
ultra-high-temperature silicone oil, vegetable oil
 Isolating Diaphragm:316L / Hastelloy C / Gold
plated on 316L / FEP or PFA plated on 316L /
Tantalum
EJC Smart Pressure Transmitter Product Overview
www.bcstgroup.com A5 BCST Group C.,Ltd
5 EJCRN Gauge Pressure Remote
Seal Transmitter
EJCRS Absolute Pressure Remote
Seal Transmitter
 Suitable for measuring the fluid medium of the
high temperature 400 ℃,high viscosity, corrosive,
easy to precipitation
 Range Limits: 0—1kPa~40MPa
 Fill fluid: silicone oil, high temperature silicone oil,
ultra-high-temperature silicone oil, vegetable oil
 Isolating Diaphragm:316L / Hastelloy C / Gold
plated on 316L / FEP or PFA plated on 316L /
Tantalum
6 EJCBP-S Sanitary Gauge Pressure
Transmitter
EJCBA-S Sanitary Absolute Pressure
Transmitter
 Measurement medium: gas, steam, liquid
 Range Limits: 0—2kPa~3MPa
 Isolating Diaphragm:316L
 Fill fluid: silicone oil, vegetable oil
7 EJCDP-S Sanitary Differential Pressure
Remote Seal Transmitter
 Measurement medium: gas, steam, liquid
 Range Limits: 0—2kPa~250kPa
 Isolating Diaphragm:316L
 Fill fluid: silicone oil, vegetable oil
8 JCMT- Multi Variable
Pressure Transmitter
 Measurement medium: gas, steam, liquid
 Range Limits: 0—2kPa~2MPA
 Isolating Diaphragm:316L / Hastelloy C / Gold
plated on 316L / FEP or PFA plated on 316L /
Tantalum
 Fill fluid: silicone oil, vegetable oil
EJC serial High Performance Differential Pressure Transmitter General Specifications
www.bcstgroup.com 1 info@bcstgroup.com
EJCDP-A High Performance Differential
Pressure Transmitter
The high performance differential pressure
transmitter EJCDP-A is suitable to measure liquid,
gas, or steam flow as well as liquid level, density and
pressure. EJCDP-A outputs a 4~20 mADC signal
corresponding to the measured differential pressure.
Its highly accurate and stable sensor can also
measure the static pressure which can be shown on
the integral indicator or remotely monitored via
HART communications. Other key features include
quick response, remote set-up using communications,
self-diagnostics and optional status output for
pressure high/low alarm.
STANDARD SPECIFICATIONS
1 PERFORMANCE SPECIFICATIONS
Reference Accuracy of Calibrated Span
(includes terminal-based linearity, hysteresis, and
repeatability)
± 0.05%
If TD>10(TD=URL/SPAN),±(0.005×TD)%
The square root accuracy is 1.5 times of reference
accuracy of calibrated span.
Ambient Temperature Effects
-20℃~65℃:±(0.075×TD+0.025)%×Span
Every 10℃ is ±0.04% ×Span (TD=1)
-40℃~-20℃ & 65℃~85℃:
±(0.1×TD+0.025)%×Span
Static Pressure Effects
±(0.025%URL+0.05%Span)/10MPa
Overpressure Effects: ±0.05%×Span /10MPa
Stability:±0.1%×Span /3 years
Power Supply Effects:
±0.001% /10V (12~42V DC)
2 FUNCTIONAL SPECIFICATIONS
Span and Range Limits
Span/
Range
Limits
kPa inH2O mbar mmH2O
C
Span
0.4~
40
1.6~
160
4~400 40~4000
Range
Limits
-40~
40
-160~
160
-400~
400
-4000~
4000
D
Span
2.5~
250
10~
1000
25~
2500
0.25~
25mH2O
Range
Limits
-250
~250
-1000
~1000
-2500
~2500
-25~
25mH2O
F
Span
30~
3000
120~
12000
0.3~
30 bar
3~
300mH2O
Range
Limits
-500
~
3000
-2000
~
12000
-5~
30bar
-5~
300mH2O
Zero Adjustment Limits
Zero can be fully elevated or suppressed, within the
lower and upper range limits of the capsule.
External Zero Adjustment
External zero is continuously adjustable with 0.01%
incremental resolution of span. Re-range can be done
locally using the range setting switch.
Mounting Position Effects
EJC serial High Performance Differential Pressure Transmitter General Specifications
www.bcstgroup.com 2 info@bcstgroup.com
Rotation in diaphragm plane has no effect. Tilting up to
90° will cause zero shift up to 0.4 kPa (40 mmH2O)
which can be corrected by the zero adjustment.
Output
Two wire 4~20 mADC output with digital
communications, linear or square root programmable.
HART FSK protocol are superimposed on the 4~20
mADC signal. Output range: 3.9 mA to 20.5 mA.
Failure Alarm (the mode can be selected)
Low Mode (min): 3.7 mA
High Mode (max): 21 mA
No Mode (hold): Keep the effective value before the
fault. Note: The standard setting of failure alarm is High
Mode.
Response Time
The amplifier damping constant is 0.1 sec; The sensor
damping constant is 0.1~1.6 sec, it depends on the
range and range compression ratio. Amplifier damping
time constant is adjustable from 0.1 to 60 sec by
software and added to response time.
UpTime < 15s
Ambient Temperature Limits
-40 to 85°C
-20 to 65°C with LCD display or fluorine rubber sealing
Storage and Transportation Temperature Limits
-50 to 85°C
-40 to 85°C with LCD display
Working Pressure Limits (Silicone oil)
Maximum working pressure:16MPa,25MPa,40MPa
Static Pressure Limits
3.5kPa abs. to maximum working pressure.
One-way Overload Pressure Limit
The maximum one-way overload pressure is maximum
working pressure.
Electromagnetic Compatibility (EMC)
Look the EMC Performance Table
Explosion Protected Type
NEPSI / ATXE: Ex dⅡC T6
NEPSI / ATXE: Ex iaⅡC T4
Amb. Temp.: -40℃~65℃
3 INSTALL
Supply & Load Requirements
24VDC supply, R ≤ (Us-12V)/Imax kΩ, Imax=23 mA.
Maximum voltage limited: 42VDC, Minimum voltage
limited: 12VDC, 15VDC(with LCD display)
230Ω to 600Ω for digital communication
Electrical Connection
The electrical connection is made via cable entry
M20x1.5.The screw terminals are suitable for wire
cross-sections up to 2.5mm2
.
Process Connection
Flange with fixing thread 7/16-20 UNF and 1/4-18 NPT
female thread on both sides.
4 PHYSICAL SPECIFICATIONS
Wetted Parts Materials
Sensor Body: 316L stainless steel
Isolating Diaphragm:316L stainless steel / Hastelloy
C/Gold plated on 316L/FEP
plated on 316L/Tantalum
Cover Flange: 316 stainless steel
Nuts and Bolts: 304 stainless steel
Process Connector: 316 stainless steel
Fill fluid: Silicone oil/Fluorinated oil
Process Connector Gasket:Perbunan(NBR)/Viton
(FKM)/Teflon(PTFE)
Amplifier Housing: Aluminum with epoxy resin coat
Housing Gasket: Perbunan(NBR)
Name plate and tag:304 stainless steel
Weight: 3.3kg
Degrees of Protection: IP67
EJC serial High Performance Differential Pressure Transmitter General Specifications
www.bcstgroup.com 3 info@bcstgroup.com
EMC Performance Table
Items Test items Basic standards Test conditions
Performance
Level
1 Radiated interference (Housing) GB/T 9254-2008 30MHz~1000MHz OK
2
Conducted interference(DC
power port)
GB/T 9254-2008 0.15MHz~30MHz OK
3
Electrostatic Discharge (ESD)
Immunity
GB/T 17626.2-2006
4kV(Line)
8kV(Air)
B
4
RF electromagnetic field
immunity
GB/T 17626.3-2006 10V/m (80MHz~1GHz) A
5
Frequency magnetic field
immunity
GB/T 17626.8-2006 30A/m A
6
Electrical Fast Transient Burst
Immunity
GB/T 17626.4-2008 2kV(5/50ns,5kHz) B
7 Surge Immunity GB/T 17626.5-2008
0.5kV(line to line)
1kV(line to ground)
(1.2us/50us)
B
8
Conducted interference
immunity induced by RF field
GB/T 17626.6-2008 3V (150KHz~80MHz) A
Note:(1)Performance level A description: The technical specifications within the limits of normal performance.
(2)Performance level B description: Temporary reduction or loss of functionality or performance, it can restore
itself. The actual operating conditions, storage, and data will not be changed.
DIMENSIONS Unit : mm
Horizontal Impulse Piping Type(side face) Horizontal Impulse Piping Type(front side)
EJC serial High Performance Differential Pressure Transmitter General Specifications
www.bcstgroup.com 4 info@bcstgroup.com
Horizontal Impulse Wall mounting Type Vertical Impulse Piping Type
5 Terminal Configuration 6 Vertical mounting flange (Code V)
Note:Quick interface functionally equivalent to the signal terminal
7 Process connections Description
EJC serial High Performance Differential Pressure Transmitter General Specifications
www.bcstgroup.com 5 info@bcstgroup.com
8 Model and suffix codes
High Performance Differential Pressure Transmitter EJCDP-
10 Accuracy
A Reference Accuracy±0.05%
20 Span
C 0-400Pa~40kPa(0-40~4000 mmH2O)/(0-4~400mbar)
D 0-2.5kPa~250kPa(0-0.25~25 mH2O)/(0-25~2500mbar)
F 0-30kPa~3MPa(0-3~300 mH2O)/(0-0.3~30bar)
30 Static pressure sensor
0 None
1 40MPa
2 10MPa
40 Diaphragm fill fluid
A 316L stainless steel Silicone oil
B 316L stainless steel Fluorinated oil
C Hastelloy C Silicone oil
D Hastelloy C Fluorinated oil
E Gold plated on 316L Silicone oil
F Gold plated on 316L Fluorinated oil
G FEP plated on 316L Silicone oil
T Tantalum Silicone oil
50 Working pressure
1 16MPa
2 25MPa
3 40MPa
60 Process connections
N 7/16-20 UNF and 1/4-18 NPT female thread, No relief valve
B 7/16-20 UNF and 1/4-18 NPT female thread, Relief valves at end of flanges
U
7/16-20 UNF and 1/4-18 NPT female thread, Relief valves at the upper part of
the flange side
D
7/16-20 UNF and 1/4-18 NPT female thread, Relief valve at the lower part of
the flange side
V
Vertical mounting flange, 7/16-20 UNF and 1/4-18 NPT female thread, Relief
valves at the upper part of the flange side
L Level(Low side can select : B/ U/ D)
R Remote Seal
70 Process connector gasket
N Perbunan(NBR)
F Viton (FKM)
P Teflon (PTFE)
80 Special function
N None
F Square root output
O Degrease cleansing treatment(Oxygen measurement must be with
EJC serial High Performance Differential Pressure Transmitter General Specifications
www.bcstgroup.com 6 info@bcstgroup.com
fluorinated oil filled capsule, Viton (FKM) gasket, <6MPa ,<60℃)
P Anti-lightning function
90 Mounting bracket
N None
1 304 stainless steel
2 Carbon steel galvanized
100 Process connector accessory
N None
1
Stainless steel oval-shaped flange with 1/2 NPT
female thread
2
Stainless steel D-shaped connector with M20x1.5 male
thread
110 Integral indicator
N None
1 LCD display
2 Backlit LCD display
120 Explosion protected type
N None
A Intrinsically safe Approval for NEPSI
D Flameproof Approval for NEPSI
B Intrinsically safe Approval for ATEX
E Gas Flameproof Approval for ATEX
G Dust Flameproof Approval for ATEX
H Gas & Dust Flameproof Approval for ATEX
130 Tag name plate
N None
1
Position number marked on the
nameplate
2 Hanging stainless steel plate
140 Housing mateiral
A Aluminium alloy
S 316 SS
Order example:EJCDP-AC2A1BNF111N1C
[A]:Reference Accuracy:±0.05% [1]:With 304 stainless steel mounting bracket
[C]:Span:0-400Pa~40kPa(0-40~4000 mmH2O) [1]:With stainless steel oval-shaped flange
[2]:Static pressure sensor:10MPa with 1/2 NPT female thread
[A]:316L stainless steel diaphragm, Silicone oil fill fluid [1]:With LCD display
[1]:Working pressure:16MPa [N]:None of explosion protected type
[B]:7/16-20 UNF and 1/4-18 NPT female thread, [1]:Position number marked on the nameplate
Relief valves at end of flanges [A]:Aluminium alloy
[N]:Perbunan(NBR)process connector gasket
[F]:Square root output
EJCB- High Performance Pressure Transmitter General Specification
www.bcstgroup.com 7 info@bcstgroup.com
EJCB-P High Performance Gauge
Pressure Transmitter
EJC-A High Performance Absolute
Pressure Transmitter
The high performance pressure transmitter EJCBP is
suitable to measure liquid, gas, or steam flow as well
as liquid level, density and pressure. EJCBP/A
outputs a 4~20mADC signal corresponding to the
measured pressure. The key features include quick
response, remote set-up using communications,
self-diagnostics and optional status output for
pressure high/low alarm.
STANDARD SPECIFICATIONS
1 PERFORMANCE SPECIFICATIONS
Reference Accuracy of Calibrated Span
(includes terminal-based linearity, hysteresis, and
repeatability)
± 0.05%
If TD>10(TD=URL/SPAN),±(0.005×TD)%
Ambient Temperature Effects
-20℃~65℃:±(0.075×TD+0.025)%×Span
Every 10℃ is ±0.04% ×Span (TD=1)
-40℃~-20℃ & 65℃~85℃:
±(0.1×TD+0.025)%×Span
Overpressure Effects: ±0.05%×Span
Stability:±0.1%×Span /3 years
Power Supply Effects:
±0.001% /10V (12~42V DC)
2 FUNCTIONAL SPECIFICATIONS
Zero Adjustment Limits
Zero can be fully elevated or suppressed, within the
lower and upper range limits of the capsule.
Span and Range Limits(RP1002-A)
Span/
Range Limits
kPa psi bar
Kgf/cm
2
C/
S
Span 2~40
0.29~
5.8
0.02
~0.4
0.02
~0.4
Range
Limits
-40~40
-5.8~
5.8
-0.4~
0.4
-0.4~
0.4
D
Span
2.5~
250
0.3625
~36.25
0.025
~2.5
0.025
~2.5
Range
Limits
-100~
250
-14.5~
36.25
-1~
2.5
-1~
2.5
F
Span
30~
3000
4.35~
435
0.3~
30
0.3~
30
Range
Limits
-100~
3000
-14.5~
435
-1~
30
-1~
30
G
Span
0.1~
10MPa
14.5~
1450
1~
100
1~
100
Range
Limits
-0.1~
10MPa
-14.5~
1450
-1~
100
-1~
100
H
Span
0.21~
21 MPa
30.45~
3045
2.1~
210
2.1~
210
Range
Limits
-0.1~21
MPa
-14.5~
8000
-1~
210
-1~
210
I
Span
0.4~40
MPa
58~
5800
4~
400
4~
400
Range
Limits
-0.1~40
MPa
-14.5~
5800
-1~
400
-1~
400
Span and Range(RP1003-A)
Span/
Range Limits
kPa psi bar Kgf/cm2
M
Span
2.5~
250
0.3625
~36.25
0.025
~2.5
0.025
~2.5
Range
Limits
0~
250
0~
36.25
0~2.5 0~2.5
O Span 30~ -4.35~ 0.3~ 0.3~
EJCB- High Performance Pressure Transmitter General Specification
www.bcstgroup.com 8 info@bcstgroup.com
3000 435 30 30
Range
Limits
0~
3000
0~435 0~30 0~30
External Zero Adjustment
External zero is continuously adjustable with 0.01%
incremental resolution of span. Re-range can be done
locally using the range setting switch.
Mounting Position Effects
Rotation in diaphragm plane has no effect. Tilting up to
90° will cause zero shift up to 0.25kPa which can be
corrected by the zero adjustment.
Output
Two wire 4~20mADC output with digital
communications, linear or square root programmable.
HART FSK protocol are superimposed on the 4~20
mADC signal. Output range: 3.9 mA to 20.5 mA
Failure Alarm (the mode can be selected)
Low Mode (min): 3.7 mA, High Mode (max): 21 mA
No Mode (hold): Keep the effective value before fault.
The standard setting of failure alarm is High Mode.
Response Time
The amplifier damping constant is 0.1 sec; The sensor
damping constant is 0.1~1.6 sec, it depends on the
range and range compression ratio. Amplifier damping
time constant is adjustable from 0.1 to 60 sec by
software and added to response time.
UpTime < 15s
Ambient Temperature Limits: -40 to 85°C
-20 to 65°C with LCD display or fluorine rubber sealing
Storage and Transportation Temperature Limits
-50 to 85°C, -40 to 85°C with LCD display
Working Pressure Limits (Silicone oil)
From vacuum to upper range limits
Overload Pressure Limits
Span 40kPa 250kPa 3MPa
(D/M) (F/O)
(C) (S)
OPL 1MPa 7MPa 4MPa 15MPa
Span 10MPa(G) 21MPa(H) 40MPa(I)
OPL 20MPa 50MPa 50MPa
Electromagnetic Compatibility (EMC)
Look the EMC Performance Table
Explosion Protected Type
NEPSI / ATEX: Ex dⅡC T6,
NEPSI / ATEX: Ex iaⅡC T4
Amb. Temp.: -40℃~65℃
3 INSTALL
Supply & Load Requirements
24VDC supply, R≤(Us-12V)/Imax kΩ, Imax=23 mA.
Maximum voltage limited: 42VDC, Minimum voltage
limited: 12VDC, 15VDC(with LCD display)
230Ω to 600Ω for digital communication
Electrical Connection
The electrical connection is made via cable entry
M20x1.5.The screw terminals are suitable for wire
cross-sections up to 2.5mm2
.
Process Connection
Default Process Connection:1/2-NPT female thread, it
can be changed to 1/2-NPT,G1/2,M20x1.5male thread
and KF16 vacuum Connection.
4 PHYSICAL SPECIFICATIONS
Isolating Diaphragm:
316L stainless steel/Hastelloy C
Process Connector: 316 stainless steel
Fill fluid: Silicone oil/Fluorinated oil
Amplifier Housing: Aluminum with epoxy resin coat
Housing Gasket: Perbunan(NBR)
Name plate and tag:304 stainless steel
Weight: 1.6kg
Degrees of Protection: IP67
EJCB- High Performance Pressure Transmitter General Specification
www.bcstgroup.com 9 info@bcstgroup.com
EMC Performance Table
Items Test items Basic standards Test conditions
Performance
Level
1 Radiated interference (Housing) GB/T 9254-2008 30MHz~1000MHz OK
2
Conducted interference(DC
power port)
GB/T 9254-2008 0.15MHz~30MHz OK
3
Electrostatic Discharge (ESD)
Immunity
GB/T 17626.2-2006
4kV(Line)
8kV(Air)
B
4
RF electromagnetic field
immunity
GB/T 17626.3-2006 10V/m (80MHz~1GHz) A
5
Frequency magnetic field
immunity
GB/T 17626.8-2006 30A/m A
6
Electrical Fast Transient Burst
Immunity
GB/T 17626.4-2008 2kV(5/50ns,5kHz) B
7 Surge Immunity GB/T 17626.5-2008
0.5kV(line to line)
1kV(line to ground)
(1.2us/50us)
B
8
Conducted interference
immunity induced by RF field
GB/T 17626.6-2008 3V (150KHz~80MHz) A
Note:(1)Performance level A description: The technical specifications within the limits of normal performance.
(2)Performance level B description: Temporary reduction or loss of functionality or performance, it can restore
itself. The actual operating conditions, storage, and data will not be changed.
DIMENSIONS Unit : mm
Horizontal Impulse Piping Type(side face) Horizontal Impulse Piping Type(front side)
EJCB- High Performance Pressure Transmitter General Specification
www.bcstgroup.com 10 info@bcstgroup.com
Horizontal Impulse Wall mounting Type Vertical Impulse Piping Type
5 Terminal Configuration
Note:Quick interface functionally equivalent to the signal terminal
6 Process connections Description
6.1 Default Process Connection(Code 1)
F/G/H/I/O Span C/S/D/M Span
EJCB- High Performance Pressure Transmitter General Specification
www.bcstgroup.com 11 info@bcstgroup.com
6.2 Other forms of Process connector
1/2-NPT male thread(Code 2) M20x1.5 male thread(Code3)
G 1/2 male thread(Code 4) Vacuum Connection DIN 28403 KF16 / ISO 2861(Code 5)
1/4-NPT male thread(Code 6)
EJCB- High Performance Pressure Transmitter General Specification
www.bcstgroup.com 12 info@bcstgroup.com
7 Model and suffix codes
High performance gauge pressure transmitter RP1002-
High performance absolute pressure transmitter RP1003-
10 Accuracy
A Reference Accuracy±0.05%
20 Span[1]
P Gauge Pressure
C 0-2kPa~40kPa /
(0-200~4000 mmH2O)
/(0-20~400mbar)
D 0-2.5kPa~250kPa /
(0-0.25~25 mH2O)
/(0-25~2500mbar)
F 0-30kPa~3MPa /(0-3~300 mH2O)/(0-0.3~30bar)
G 0-0.1MPa~10MPa /(0-1~100bar)
H 0-0.21MPa~21MPa /(0-2.1~210 bar)
I 0-0.4MPa~40MPa /(0-4~400 bar)
S 0-2kPa~40kPa /(0-200~4000 mmH2O)/(0-20~400mbar) 【Overload protection 7MPa】
A Absolute Pressure
M 0-2.5kPa~250kPa /(0-25~2500mbar)
O 0-30kPa~3MPa /(0-0.3~30bar)
30 Diaphragm fill fluid
A 316L stainless steel Silicone oil
B 316L stainless steel Fluorinated oil
C Hastelloy C Silicone oil
D Hastelloy C Fluorinated oil
40 Process connector accessory
1 1/2-NPT female thread
2 1/2-NPT male thread (Containing 1/4-NPT female thread)
3 M20x1.5 female thread
4 G 1/2 female thread
5 Vacuum Connection DIN 28403 KF16 / ISO 2861[2]
6 1/4-NPT male thread
R Remote Seal
50 Special function
N None
0
Degrease cleansing treatment(Oxygen measurement must be with fluorinated oil
filled capsule, Viton (FKM) gasket, <6MPa ,<60℃)
P Anti-lightning function
60 Mounting bracket
N None
1 304 stainless steel
2 Carbon steel galvanized
70 Integral indicator
N None
1 LCD display
2 Backlit LCD display
80 Explosion protected type
EJCB- High Performance Pressure Transmitter General Specification
www.bcstgroup.com 13 info@bcstgroup.com
N None
A Intrinsically safe Approval for NEPSI
D Flameproof Approval for NEPSI
B Intrinsically safe Approval for ATEX
E Gas Flameproof Approval for ATEX
G Dust Flameproof Approval for ATEX
H Gas & Dust Flameproof Approval for ATEX
90 Tag name plate
N None
1 Position number marked on the nameplate
2 Hanging stainless steel plate
100 Housing material
A Aluminium alloy
S Stainless Steel
110 Additional options(apply only to the range S)[3]
N Perbunan(NBR)
F Viton (FKM)
P Teflon (PTFE)
Note 1:
EJCBP corresponding to select gauge pressure range code, EJCBA corresponding to select absolute pressure
range code;
Note 2:Vacuum Connection DIN 28403 KF16 / ISO 2861, applies only to the range of less than 2,5 bar;
Note 3 :Additional options apply only to the range S, need to choose a suitable O-ring material according to the
measuring medium,the default option is NBR.
Order example:
For example:EJCB1P-ACA1P11N1CN
[EJCB1-]:High performance gauge pressure transmitter,Reference Accuracy:±0.05%
[P]:Gauge Pressure
[C]:Span:0-2kPa~40kPa /(0-200~4000 mmH2O)/(0-20~400mbar)
[A]:316L stainless steel diaphragm, Silicone oil fill fluid
[1]:1/2-NPT female thread process connector
[P]:With anti-lightning function
[1]:With 304 stainless steel mounting bracket
[1]:With LCD display
[N]:None of explosion protected type
[1]:Position number marked on the nameplate
[A]:Aluminium alloy
EJCDP-B/C Differential Pressure Transmitter General Specifications
www.bcstgroup.com 14 info@bcstgroup.com
EJCDP-B Differential Pressure Transmitter
EJCDP-C Differential Pressure Transmitter
The differential pressure transmitter EJCDP-B/C is
suitable to measure liquid, gas, or steam flow as well
as liquid level, density and pressure. EJCDP- B/C
outputs a 4~20mADC signal corresponding to the
measured differential pressure. Its highly accurate
and stable sensor can also measure the static
pressure which can be shown on the integral
indicator or remotely monitored via HART
communications. Other key features include quick
response, remote set-up using communications,
self-diagnostics and optional status output for
pressure high/low alarm.
STANDARD SPECIFICATIONS
1 PERFORMANCE SPECIFICATIONS
Reference Accuracy of Calibrated Span (includes
terminal-based linearity, hysteresis, and repeatability)
EJCDP-B:± 0.075%; EJCDP-C:± 0.1%
If TD>10 (TD=URL/SPAN):
EJCDP-B:±(0.0075×TD)%;EJCDP-C:±(0.01×TD)%
The square root accuracy is 1.5 times of reference
accuracy of calibrated span.
Ambient Temperature Effects
-20℃~65℃:±(0.15×TD+0.05)%×Span
Every 10℃ is ±0.08% ×Span (TD=1)
-40℃~-20℃ & 65℃~85℃:±(0.3×TD+0.1)%×Span
Static Pressure Effects
±(0.05%URL+0.075%Span)/10MPa
Overpressure Effects: ±0.1%×Span /10MPa。
Stability: ±0.1%×Span /3 years
Power Supply Effects
±0.001% /10V (12~42V DC)
2 FUNCTIONAL SPECIFICATIONS
Span and Range Limits
Span/
Range
Limits
kPa inH2O mbar mmH2O
B
Span 0.2~6 0.8~24 2~60 20~600
Range
Limits
-6~6 -24~24
-60~
60
-600~
600
C
Span
0.4~
40
1.6~
160
4~400
40~
4000
Range
Limits
-40~
40
-160~
160
-400~
400
-4000~
4000
D
Span
2.5~
250
10~
1000
25~
2500
0.25~
25mH2O
Range
Limits
-250~
250
-1000~
1000
-2500
~2500
-25~
25mH2O
F
Span
30~
3000
120~
12000
0.3~
30bar
3~
300mH2O
Range
Limits
-500~
3000
-2000~
12000
-5~
30bar
-5~
300mH2O
Zero Adjustment Limits
Zero can be fully elevated or suppressed, within the
lower and upper range limits of the capsule.
External Zero Adjustment
External zero is continuously adjustable with 0.01%
incremental resolution of span. Re-range can be done
locally using the range setting switch.
EJCDP-B/C Differential Pressure Transmitter General Specifications
www.bcstgroup.com 15 info@bcstgroup.com
Mounting Position Effects
Rotation in diaphragm plane has no effect. Tilting up to
90 degree will cause zero shift up to 0.4 kPa which can
be corrected by the zero adjustment.
Output
Two wire 4~20mADC output with digital
communications, linear or square root programmable.
HART FSK protocol are superimposed on the 4~20
mADC signal. Output range: 3.9 mA to 20.5 mA.
Failure Alarm (the mode can be selected)
Low Mode (min): 3.7 mA
High Mode (max): 21 mA
No Mode (hold): Keep the effective value before the
fault. Note: The standard setting of failure alarm is High
Mode.
Response Time
The amplifier damping constant is 0.1 sec; The sensor
damping constant is 0.1~1.6 sec, it depends on the
range and range compression ratio. Amplifier damping
time constant is adjustable from 0.1 to 60 sec by
software and added to response time.
UpTime < 15s
Ambient Temperature Limits
-40 to 85°C
-20 to 65°C with LCD display or fluorine rubber sealing
Storage and Transportation Temperature Limits
-50 to 85°C; -40 to 85°C with LCD display
Working Pressure Limits (Silicone oil)
Maximum working pressure: 16MPa,25MPa,40MPa
Static Pressure Limits
3.5kPa abs. to maximum working pressure.
One-way Overload Pressure Limit
The maximum one-way overload pressure is maximum
working pressure.
Electromagnetic Compatibility (EMC)
Look the EMC Performance Table
Explosion Protected Type
NEPSI / ATEX: Ex dⅡC T6
NEPSI / ATEX: Ex iaⅡC T4
Amb. Temp.: -40℃~65℃
3 INSTALL
Supply & Load Requirements
24VDC supply, R ≤ (Us-12V)/Imax kΩ, Imax=23 mA.
Maximum voltage limited: 42VDC, Minimum voltage
limited: 12VDC, 15VDC(with LCD display)
230Ω to 600Ω for digital communication
Electrical Connection
The electrical connection is made via cable entry
M20x1.5.The screw terminals are suitable for wire
cross-sections up to 2.5mm2
.
Process Connection
Flange with fixing thread 7/16-20 UNF and 1/4-18 NPT
female thread on both sides.
4 PHYSICAL SPECIFICATIONS
Wetted Parts Materials
Sensor Body: 316L stainless steel
Isolating Diaphragm:316L stainless steel / Hastelloy
C/Gold plated on 316L/FEP
plated on 316L/Tantalum
Cover Flange: 316 stainless steel
Nuts and Bolts: 304 stainless steel
Process Connector: 316 stainless steel
Fill fluid: Silicone oil/Fluorinated oil
Process Connector Gasket:Perbunan(NBR)/Viton
(FKM)/Teflon(PTFE)
Amplifier Housing: Aluminum with epoxy resin coat
Housing Gasket: Perbunan(NBR)
Name plate and tag:304 stainless steel
Weight: 3.3kg
Degrees of Protection: IP67
EJCDP-B/C Differential Pressure Transmitter General Specifications
www.bcstgroup.com 16 info@bcstgroup.com
EMC Performance Table
Items Test items Basic standards Test conditions
Performance
Level
1 Radiated interference (Housing) GB/T 9254-2008 30MHz~1000MHz OK
2
Conducted interference(DC
power port)
GB/T 9254-2008 0.15MHz~30MHz OK
3
Electrostatic Discharge (ESD)
Immunity
GB/T 17626.2-2006
4kV(Line)
8kV(Air)
B
4
RF electromagnetic field
immunity
GB/T 17626.3-2006 10V/m (80MHz~1GHz) A
5
Frequency magnetic field
immunity
GB/T 17626.8-2006 30A/m A
6
Electrical Fast Transient Burst
Immunity
GB/T 17626.4-2008 2kV(5/50ns,5kHz) B
7 Surge Immunity GB/T 17626.5-2008
0.5kV(line to line)
1kV(line to ground)
(1.2us/50us)
B
8
Conducted interference
immunity induced by RF field
GB/T 17626.6-2008 3V (150KHz~80MHz) A
Note:(1)Performance level A description: The technical specifications within the limits of normal performance.
(2)Performance level B description: Temporary reduction or loss of functionality or performance, it can restore
itself. The actual operating conditions, storage, and data will not be changed.
DIMENSIONS Unit : mm
Horizontal Impulse Piping Type(side face) Horizontal Impulse Piping Type(front side)
EJCDP-B/C Differential Pressure Transmitter General Specifications
www.bcstgroup.com 17 info@bcstgroup.com
Horizontal Impulse Wall mounting Type Vertical Impulse Piping Type
5 Terminal Configuration 6 Vertical mounting flange (Code V)
Note:Quick interface functionally equivalent to the signal terminal
7 Process connections Description
EJCDP-B/C Differential Pressure Transmitter General Specifications
www.bcstgroup.com 18 info@bcstgroup.com
8 Model and suffix codes
Differential Pressure Transmitter EJCDP-
10 Accuracy
B Reference Accuracy±0.075%
C Reference Accuracy±0.1%
20 Span
B 0-200Pa~6kPa(0-20~600 mmH2O)/(0-2~60mbar)
C 0-400Pa~40kPa(0-40~4000 mmH2O)/(0-20~400mbar)
D 0-2.5kPa~250kPa(0-0.25~25 mH2O)/(0-25~2500mbar)
F 0-30kPa~3MPa(0-3~300 mH2O)/(0-0.3~30bar)
30 Static pressure sensor
0 None
1 40MPa
2 10MPa
40 Diaphragm fill fluid
A 316L stainless steel Silicone oil
B 316L stainless steel Fluorinated oil
C Hastelloy C Silicone oil
D Hastelloy C Fluorinated oil
E Gold plated on 316L Silicone oil
F Gold plated on 316L Fluorinated oil
G FEP plated on 316L Silicone oil
T Tantalum Silicone oil
50 Working pressure
1 16MPa
2 25MPa
3 40MPa
60 Process connections
N 7/16-20 UNF and 1/4-18 NPT female thread, No relief valve
B 7/16-20 UNF and 1/4-18 NPT female thread, Relief valves at end of flanges
U
7/16-20 UNF and 1/4-18 NPT female thread, Relief valves at the upper part of
the flange side
D
7/16-20 UNF and 1/4-18 NPT female thread, Relief valve at the lower part of
the flange side
V
Vertical mounting flange, 7/16-20 UNF and 1/4-18 NPT female thread, Relief
valves at the upper part of the flange side
L Level(Low side can select : B/ U/ D)
R Remote Seal
70 Process connector gasket
N Perbunan(NBR)
F Viton (FKM)
P Teflon (PTFE)
80 Special function
N None
EJCDP-B/C Differential Pressure Transmitter General Specifications
www.bcstgroup.com 19 info@bcstgroup.com
F Square root output
O
Degrease cleansing treatment(Oxygen measurement must be with
fluorinated oil filled capsule, Viton (FKM) gasket, <6MPa ,<60℃)
P Anti-lightning function
90 Mounting bracket
N None
1 304 stainless steel
2 Carbon steel galvanized
100 Process connector accessory
N None
1
Stainless steel oval-shaped flange with 1/2 NPT
female thread
2
Stainless steel D-shaped connector with M20x1.5 male
thread
110 Integral indicator
N None
1 LCD display
2 Backlit LCD display
120 Explosion protected type
N None
A Intrinsically safe Approval for NEPSI
D Flameproof Approval for NEPSI
B Intrinsically safe Approval for ATEX
E Gas Flameproof Approval for ATEX
G Dust Flameproof Approval for ATEX
H Gas & Dust Flameproof Approval for ATEX
130 Tag name plate
N None
1 Position number on the nameplate
2 Hanging stainless steel plate
140 Manual
C Chinese
E English
Order example:For example:EJCDP-BC2A1BNF111N1C
[B]:Reference Accuracy:±0.075% [1]:With 304 stainless steel mounting bracket
[C]:Span:0-400Pa~40kPa(0-40~4000 mmH2O) [1]:With stainless steel oval-shaped flange
[2]:Static pressure sensor:10MPa with 1/2 NPT female thread
[A]:316L stainless steel diaphragm, Silicone oil fill fluid [1]:With LCD display
[1]:Working pressure:16MPa [N]:None of explosion protected type
[B]:7/16-20 UNF and 1/4-18 NPT female thread, [1]:Position number marked on the nameplate
Relief valves at end of flanges [C]:Chinese manual
[N]:Perbunan(NBR)process connector gasket
[F]:Square root output
EJCBP Pressure Transmitter General Specifications
www.bcstgroup.com 20 BCST Group Co.,Ltd
EJCBP Gauge Pressure Transmitter
EJCBA Absolute Pressure Transmitter
The pressure transmitter EJCBP/BA is suitable to
measure liquid, gas, or steam flow as well as liquid
level, density and pressure. RP1002/3-B/C outputs a
4~20mADC signal corresponding to the measured
pressure. The key features include quick response,
remote set-up using communications,
self-diagnostics and optional status output for
pressure high/low alarm.
STANDARD SPECIFICATIONS
1 PERFORMANCE SPECIFICATIONS
Reference Accuracy of Calibrated Span (includes
terminal-based linearity, hysteresis, and repeatability)
RP1001-B:± 0.075%;
RP1001-C:± 0.1%
If TD>10 (TD=URL/SPAN):
EJCBP:±(0.0075×TD)%;
EJCBA:±(0.01×TD)%
Ambient Temperature Effects
-20℃~65℃:
±(0.15×TD+0.05)%×Span
Every 10℃ is ±0.08% ×Span (TD=1)
-40℃~-20℃ & 65℃~85℃:
±(0.2×TD+0.05)%×Span
Overpressure Effects
±0.05%×Span
Stability
±0.1%×Span /3 years
Power Supply Effects:
±0.001% /10V (12~42V DC)
2 FUNCTIONAL SPECIFICATIONS
Span and Range Limits (RP1002-B/C)
Span/
Range Limits
kPa psi bar Kgf/cm2
B/
R
Span 0.6~6
0.087
~0.87
6~60
mbar
0.006
~0.06
Range
Limits
-6~6
-0.87~
0.87
-60~
60
mbar
-0.06
~0.06
C
/S
Span 2~40
0.29~
5.8
0.02~
0.4
0.02~
0.4
Range
Limits
-40~
40
-5.8~
5.8
-0.4~
0.4
-0.4~
0.4
D
Span
2.5~
250
0.3625
~
36.25
0.025
~2.5
0.025
~2.5
Range
Limits
-100~
250
-14.5~
36.25
-1~
2.5
-1~
2.5
F
Span
30~
3000
4.35~
435
0.3~
30
0.3~
30
Range
Limits
-100~
3000
-14.5~
435
-1~30 -1~30
G
Span
0.1~
10MPa
14.5~
1450
1~
100
1~100
Range
Limits
-0.1~
10MPa
-14.5~
1450
-1~
100
-1~
100
H
Span
0.21~
21
MPa
30.45
~3045
2.1~
210
2.1~
210
Range
Limits
-0.1~
21
MPa
-14.5~
8000
-1~
210
-1~
210
EJCBP Pressure Transmitter General Specifications
www.bcstgroup.com 21 BCST Group Co.,Ltd
I
Span
0.4~
40
MPa
58~
5800
4~
400
4~
400
Range
Limits
-0.1~
40
MPa
-14.5~
5800
-1~
400
-1~
400
Span and Range Limits (RP1003-B/C)
Span/
Range Limits
kPa psi bar Kgf/cm2
L/
T
Span
2~
40
0.29~
5.8
0.02~
0.4
0.02~
0.4
Range
Limits
0~
40
0~5.8 0~0.4 0~0.4
M
Span
2.5~
250
0.3625
~36.25
0.025
~2.5
0.025
~2.5
Range
Limits
0~
250
0~
36.25
0~2.5 0~2.5
O
Span
30~
3000
4.35~
435
0.3~
30
0.3~
30
Range
Limits
0~
3000
0~435 0~30 0~30
External Zero Adjustment
External zero is continuously adjustable with 0.01%
incremental resolution of span. Re-range can be done
locally using the range setting switch.
Mounting Position Effects
Rotation in diaphragm plane has no effect. Tilting up to
90° will cause zero shift up to 0.25kPa which can be
corrected by the zero adjustment.
Output
Two wire 4~20mADC output with digital
communications, linear or square root programmable.
HART FSK protocol are superimposed on the 4~20
mADC signal. Output range: 3.9 mA to 20.5 mA
Failure Alarm (the mode can be selected)
Low Mode (min): 3.7 mA, High Mode (max): 21 mA
No Mode (hold): Keep the effective value before fault.
The standard setting of failure alarm is High Mode.
Response Time
The amplifier damping constant is 0.1 sec; The sensor
damping constant is 0.1~1.6 sec, it depends on the
range and range compression ratio. Amplifier damping
time constant is adjustable from 0.1 to 60 sec by
software and added to response time.
Up Time < 15s
Ambient Temperature Limits: -40 to 85°C
-20 to 65°C with LCD display or fluorine rubber sealing
Storage and Transportation Temperature Limits
-50 to 85°C, -40 to 85°C with LCD display
Working Pressure Limits (Silicone oil)
From vacuum to upper range limits
Overload Pressure Limits
Span
40kPa 250kPa
(D/M)
3MPa
(F/O)
(C) (S)
OPL 1MPa 7MPa 4MPa 15MPa
Span 10MPa(G) 21MPa(H) 40MPa(I)
OPL 20MPa 50MPa 50MPa
Electromagnetic Compatibility (EMC)
Look the EMC Performance Table
Explosion Protected Type
NEPSI / ATEX: Ex dⅡC T6,
NEPSI / ATEX: Ex iaⅡC T4
Amb. Temp.: -40℃~65℃
3 INSTALL
Supply & Load Requirements
24VDC supply, R ≤ (Us-12V)/Imax kΩ, Imax=23 mA.
Maximum voltage limited: 42VDC, Minimum voltage
limited: 12VDC, 15VDC(with LCD display)
230Ω to 600Ω for digital communication
Electrical Connection
The electrical connection is made via cable entry
M20x1.5.The screw terminals are suitable for wire
cross-sections up to 2.5mm2
.
Process Connection
Default Process Connection:1/2-NPT female thread, it
EJCBP Pressure Transmitter General Specifications
www.bcstgroup.com 22 BCST Group Co.,Ltd
can be changed to 1/2-NPT,G1/2,M20x1.5male thread
and KF16 vacuum Connection.
4 PHYSICAL SPECIFICATIONS
Isolating Diaphragm:
316L stainless steel/Hastelloy C
Process Connector: 316 stainless steel
Fill fluid: Silicone oil/Fluorinated oil
Amplifier Housing: Aluminum with epoxy resin coat
Housing Gasket: Perbunan(NBR)
Name plate and tag:304 stainless steel
Weight: 1.6kg
Degrees of Protection: IP67
EMC Performance Table
Items Test items Basic standards Test conditions
Performance
Level
1 Radiated interference (Housing) GB/T 9254-2008 30MHz~1000MHz OK
2
Conducted interference(DC
power port)
GB/T 9254-2008 0.15MHz~30MHz OK
3
Electrostatic Discharge (ESD)
Immunity
GB/T 17626.2-2006
4kV(Line)
8kV(Air)
B
4
RF electromagnetic field
immunity
GB/T 17626.3-2006 10V/m (80MHz~1GHz) A
5
Frequency magnetic field
immunity
GB/T 17626.8-2006 30A/m A
6
Electrical Fast Transient Burst
Immunity
GB/T 17626.4-2008 2kV(5/50ns,5kHz) B
7 Surge Immunity GB/T 17626.5-2008
0.5kV(line to line)
1kV(line to ground)
(1.2us/50us)
B
8
Conducted interference
immunity induced by RF field
GB/T 17626.6-2008 3V (150KHz~80MHz) A
Note:(1)Performance level A description: The technical specifications within the limits of normal performance.
(2)Performance level B description: Temporary reduction or loss of functionality or performance, it can restore
itself. The actual operating conditions, storage, and data will not be changed.
DIMENSIONS Unit : mm
Horizontal Impulse Piping Type(side face) Horizontal Impulse Piping Type(front side)
EJCBP/BA Pressure Transmitter General Specifications
www.bcstgroup.com 23 BCST Group Co.,Ltd
Horizontal Impulse Wall mounting Type Vertical Impulse Piping Type
5 Terminal Configuration
Note:Quick interface functionally equivalent to the signal terminal
6 Process connections Description
6.1 Default Process Connection(Code 1)
F/G/H/I/O Span B/C/R/S/L/T/M/D Span
EJCBP/BA Pressure Transmitter General Specifications
www.bcstgroup.com 24 BCST Group Co.,Ltd
6.2 Other forms of Process connector
1/2-NPT male thread(Code 2) M20x1.5 male thread(Code3)
G 1/2 male thread(Code 4) Vacuum Connection DIN 28403 KF16 / ISO 2861(Code 5)
1/4-NPT male thread(Code 6)
EJCBP/BA Pressure Transmitter General Specifications
www.bcstgroup.com 25 BCST Group Co.,Ltd
7 Model and suffix codes
Gauge Pressure Transmitter EJCBP -
Absolute Pressure Transmitter EJCBA -
10 Accuracy
1 Reference Accuracy±0.075%
2 Reference Accuracy±0.1%
20 Span[1]
P Gauge Pressure
B 0-0.6kPa~6kPa /(0-60~600 mmH2O)/(0-6~60mbar)
C 0-2kPa~40kPa /
(0-200~4000 mmH2O)
/(0-20~400mbar)
D 0-2.5kPa~250kPa /
(0-0.25~25 mH2O)
/(0-25~2500mbar)
F 0-30kPa~3MPa /(0-3~300 mH2O)/(0-0.3~30bar)
G 0-0.1MPa~10MPa /(0-1~100bar)
H 0-0.21MPa~21MPa /(0-2.1~210 bar)
I 0-0.4MPa~40MPa /(0-4~400 bar)
R 0-0.6kPa~6kPa /(0-60~600 mmH2O)/(0-6~60mbar) 【Overload protection 7MPa】
S 0-2kPa~40kPa /(0-200~4000 mmH2O)/(0-20~400mbar) 【Overload protection 7MPa】
A Absolute Pressure
L 0-2kPa~40kPa /(0-200~4000 mmH2O)/(0-20~400mbar)
M 0-2.5kPa~250kPa /(0-25~2500mbar)
O 0-30kPa~3MPa /(0-0.3~30bar)
T 0-2kPa~40kPa /(0-200~4000 mmH2O)/(0-20~400mbar) 【Overload protection 7MPa】
30 Diaphragm fill fluid
A 316L stainless steel Silicone oil
B 316L stainless steel Fluorinated oil
C Hastelloy C Silicone oil
D Hastelloy C Fluorinated oil
40 Process connector accessory
1 1/2-NPT female thread
2 1/2-NPT male thread (Containing 1/4-NPT female thread)
3 M20x1.5 female thread
4 G 1/2 female thread
5 Vacuum Connection DIN 28403 KF16 / ISO 2861[2]
6 1/4-NPT male thread
R Remote Seal
50 Special function
N None
0
Degrease cleansing treatment(Oxygen measurement must be with fluorinated oil
filled capsule, Viton (FKM) gasket, <6MPa ,<60℃)
P Anti-lightning function
60 Mounting bracket
N None
1 304 stainless steel
2 Carbon steel galvanized
EJCBP/BA Pressure Transmitter General Specifications
www.bcstgroup.com 26 BCST Group Co.,Ltd
70 Integral indicator
N None
1 LCD display
2 Backlit LCD display
80 Explosion protected type
N None
A Intrinsically safe Approval for NEPIS
D Flameproof Approval for NEPSI
B Intrinsically safe Approval for ATEX
E Gas Flameproof Approval for ATEX
G Dust Flameproof Approval for ATEX
H Gas & Dust Flameproof Approval for ATEX
90 Tag name plate
N None
1 Position number marked on the nameplate
2 Hanging stainless steel plate
100 Housing material
A Aluminium alloy
S 316SS
110 Additional options(apply only to the range R/S/T)[3]
N Perbunan(NBR)
F Viton (FKM)
P Teflon (PTFE)
Note 1 : EJCBP corresponding to select gauge pressure range code, RP1003 corresponding to select absolute
pressure range code;
Note 2:Vacuum Connection DIN 28403 KF16 / ISO 2861, applies only to the range of less than 2,5 bar;
Note 3:Additional options apply only to the range R/S/T, need to choose a suitable O-ring material according to the
measuring medium,the default option is NBR.
Order example:
For example:EJCBP -BCA1P11N1CN
[RP1002-]:Gauge pressure transmitter
[B]:Reference Accuracy:±0.075%
[C]:Span:0-2kPa~40kPa /(0-200~4000 mmH2O)/(0-20~400mbar)
[A]:316L stainless steel diaphragm, Silicone oil fill fluid
[1]:1/2-NPT female thread process connector
[P]:With anti-lightning function
[1]:With 304 stainless steel mounting bracket
[1]:With LCD display
[N]:None of explosion protected type
[1]:Position number marked on the nameplate
[A]:Aluminium alloy
EJC Micro-differential pressure transmitter General Specifications
www.bcstgroup.com 27 BCST Group Co.,Ltd
EJCDM
Micro-differential Pressure Transmitter
The micro-differential pressure transmitter EJCDM is
suitable to measure liquid, gas, or steam flow as well
as liquid level, density and pressure. EJCDM -
outputs a 4~20mADC signal corresponding to the
measured differential pressure. Its highly accurate
and stable sensor can also measure the static
pressure which can be shown on the integral
indicator or remotely monitored via HART
communications. Other key features include quick
response, remote set-up using communications,
self-diagnostics and optional status output for
pressure high/low alarm.
STANDARD SPECIFICATIONS
1 PERFORMANCE SPECIFICATIONS
Reference Accuracy of Calibrated Span (includes
terminal-based linearity, hysteresis, and repeatability)
EJCDM-B:± 0.075%; EJCDM-C:± 0.1%
EJCDM-D:± 0.25%
If TD>2.5 (TD= URL/SPAN),
EJCDM-B:
±(0.03×TD)%; EJCDM-C:
±(0.04×TD)%
EJCDM-D:±(0.1×TD)%
The square root accuracy is 1.5 times of reference
accuracy of calibrated span.
Ambient Temperature Effects
EJCDM-B/C:
-20℃~65℃ ±(0.25×TD+0.15)%×Span
Every 10℃ is ±0.08% ×Span (TD=1)
-40℃~-20℃ & 65℃~85℃:
±(0.25×TD+0.15)%×Span
EJCDM-D:
-20℃~65℃:±(0.35×TD+0.15)%×Span
Every 10℃ is ±0.16% ×Span (TD=1)
-40℃~-20℃ & 65℃~85℃:
±(0.35×TD+0.15)%×Span
Overpressure Effects: ±0.1%×Span
Static Pressure Effects
EJCDM-B/C:
±(0.05%URL+0.075%Span)/Working Pressure
EJCDM-D:
±(0.1%URL+0.15%Span)/Working Pressure
Stability:Reference Accuracy ×Span /3 years
Power Supply Effects:
±0.001% /10V (12~42V DC)
2 FUNCTIONAL SPECIFICATIONS
Span and Range Limits
Span/
Range Limits
kPa inH2O mbar
mmH2
O
A0/
A7
Span
0.1
~1
0.4~4 1~10
10~
100
Range
Limits
-1~
1
-4~4
-10~
10
-100~
100
Zero Adjustment Limits
Zero can be fully elevated or suppressed, within the
lower and upper range limits of the capsule.
External Zero Adjustment
External zero is continuously adjustable with 0.01%
incremental resolution of span. Re-range can be done
locally using the range setting switch.
Mounting Position Effects
EJC Micro-differential pressure transmitter General Specifications
www.bcstgroup.com 28 BCST Group Co.,Ltd
Rotation in diaphragm plane has no effect. Tilting up to
90 degree will cause zero shift up to 0.4 kPa which can
be corrected by the zero adjustment.
Output
Two wire 4~20mADC output with digital
communications, linear or square root programmable.
HART FSK protocol are superimposed on the 4~20
mADC signal. Output range: 3.9 mA to 20.5 mA.
Failure Alarm (the mode can be selected)
Low Mode (min): 3.7 mA
High Mode (max): 21 mA
No Mode (hold): Keep the effective value before the
fault. Note: The standard setting of failure alarm is High
Mode.
Response Time
The amplifier damping constant is 0.1 sec; The sensor
damping constant is 0.1~1.6 sec, it depends on the
range and range compression ratio. Amplifier damping
time constant is adjustable from 0.1 to 60 sec by
software and added to response time.
UpTime < 15s
Ambient Temperature Limits
-40 to 85°C
-20 to 65°C with LCD display or fluorine rubber sealing
Storage and Transportation Temperature Limits
-50 to 85°C
-40 to 85°C with LCD display
Working Pressure Limits (Silicone oil)
Maximum working pressure:0.2MPa,7MPa
Static Pressure Limits
3.5kPa abs. to maximum working pressure.
One-way Overload Pressure Limit
The maximum one-way overload pressure is maximum
working pressure.
Electromagnetic Compatibility (EMC)
Look the EMC Performance Table
Explosion Protected Type
NEPSI / ATEX: Ex dⅡC T6
NEPSI / ATEX: Ex iaⅡC T4
Amb. Temp.: -40℃~65℃
3 INSTALL
Supply & Load Requirements
24VDC supply, R ≤ (Us-12V)/Imax kΩ, Imax=23 mA.
Maximum voltage limited: 42VDC, Minimum voltage
limited: 12VDC, 15VDC(with LCD display)
230Ω to 600Ω for digital communication
Electrical Connection
The electrical connection is made via cable entry
M20x1.5.The screw terminals are suitable for wire
cross-sections up to 2.5mm2
.
Process Connection
Flange with fixing thread 7/16-20 UNF and 1/4-18 NPT
female thread on both sides.
4 PHYSICAL SPECIFICATIONS
Wetted Parts Materials
Sensor Body: 316L stainless steel
Isolating Diaphragm:316L stainless steel / Hastelloy
C/Gold plated on 316L
Cover Flange: 316 stainless steel
Nuts and Bolts: 304 stainless steel
Process Connector: 316 stainless steel
Fill fluid: Silicone oil/Fluorinated oil
Process Connector Gasket:Perbunan(NBR)/Viton
(FKM)/Teflon(PTFE)
Amplifier Housing: Aluminum with epoxy resin coat
Housing Gasket: Perbunan(NBR)
Name plate and tag:304 stainless steel
Weight: 3.3kg
Degrees of Protection: IP67
EJC Micro-differential pressure transmitter General Specifications
www.bcstgroup.com 29 BCST Group Co.,Ltd
EMC Performance Table
Items Test items Basic standards Test conditions
Performance
Level
1 Radiated interference (Housing) GB/T 9254-2008 30MHz~1000MHz OK
2
Conducted interference(DC
power port)
GB/T 9254-2008 0.15MHz~30MHz OK
3
Electrostatic Discharge (ESD)
Immunity
GB/T 17626.2-2006
4kV(Line)
8kV(Air)
B
4
RF electromagnetic field
immunity
GB/T 17626.3-2006 10V/m (80MHz~1GHz) A
5
Frequency magnetic field
immunity
GB/T 17626.8-2006 30A/m A
6
Electrical Fast Transient Burst
Immunity
GB/T 17626.4-2008 2kV(5/50ns,5kHz) B
7 Surge Immunity GB/T 17626.5-2008
0.5kV(line to line)
1kV(line to ground)
(1.2us/50us)
B
8
Conducted interference
immunity induced by RF field
GB/T 17626.6-2008 3V (150KHz~80MHz) A
Note:(1)Performance level A description: The technical specifications within the limits of normal performance.
(2)Performance level B description: Temporary reduction or loss of functionality or performance, it can restore
itself. The actual operating conditions, storage, and data will not be changed.
DIMENSIONS Unit : mm
Horizontal Impulse Piping Type(side face) Horizontal Impulse Piping Type(front side)
EJC Micro-differential pressure transmitter General Specifications
www.bcstgroup.com 30 BCST Group Co.,Ltd
Horizontal Impulse Wall mounting Type Vertical Impulse Piping Type
5 Terminal Configuration
Note:Quick interface functionally equivalent to the signal terminal
6 Process connections Description
EJC Micro-differential pressure transmitter General Specifications
www.bcstgroup.com 31 BCST Group Co.,Ltd
7 Model and suffix codes
Micro-differential Pressure Transmitter EJCDM-
10 Accuracy
B Reference Accuracy±0.075%
C Reference Accuracy±0.1%
D Reference Accuracy±0.25%
20 Span
A0 0-100Pa~1kPa(0-10~100 mmH2O)working pressure 0.2MPa
A7 0-100Pa~1kPa(0-10~100 mmH2O)working pressure 7MPa
30 Static pressure sensor
0 None
1 250kPa(apply only to 0.2MPa working pressure)
2 10MPa (apply only to 7MPa working pressure)
40 Diaphragm fill fluid
A 316L stainless steel Silicone oil
B 316L stainless steel Fluorinated oil
C Hastelloy C Silicone oil
D Hastelloy C Fluorinated oil
E Gold plated on 316L Silicone oil
F Gold plated on 316L Fluorinated oil
50 Process connections
N 7/16-20 UNF and 1/4-18 NPT female thread, No relief valve
B 7/16-20 UNF and 1/4-18 NPT female thread, Relief valves at end of flanges
U
7/16-20 UNF and 1/4-18 NPT female thread, Relief valves at the upper part of
the flange side
D
7/16-20 UNF and 1/4-18 NPT female thread, Relief valve at the lower part of
the flange side
60 Process connector gasket
N Perbunan(NBR)
F Viton (FKM)
P Teflon (PTFE)
70 Special function
N None
F Square root output
O
Degrease cleansing treatment(Oxygen measurement must be with
fluorinated oil filled capsule, Viton (FKM) gasket, <6MPa ,<60℃)
P Anti-lightning function
80 Mounting bracket
N None
1 304 stainless steel
2 Carbon steel galvanized
90 Process connector accessory
N None
1 Stainless steel oval-shaped flange with 1/2 NPT female
EJC Micro-differential pressure transmitter General Specifications
www.bcstgroup.com 32 BCST Group Co.,Ltd
thread
2
Stainless steel D-shaped connector with M20x1.5 male
thread
100 Integral indicator
N None
1 LCD display
2 Backlit LCD display
110 Explosion protected type
N None
A Intrinsically safe standard ,Ex iaⅡC T4
D Explosion-proof ,Ex dⅡC T6,
120 Tag name plate
N None
1
Position number marked on the
nameplate
2 Hanging stainless steel plate
130 Housing material
A Aluminium alloy
S 316SS
Order example:
For example:EJCDM-BA02ABNF111N1C
[B]:Reference Accuracy:±0.075%
[A0]:0-100Pa~1kPa(0-10~100 mmH2O)working pressure 0.2MPa
[2]:Static pressure sensor:10MPa
[A]:316L stainless steel diaphragm, Silicone oil fill fluid
[B]:7/16-20 UNF and 1/4-18 NPT female thread, Relief valves at end of flanges
[N]:Perbunan(NBR)process connector gasket
[F]:Square root output
[1]:With 304 stainless steel mounting bracket
[1]:With stainless steel oval-shaped flange with 1/2 NPT female thread
[1]:With LCD display
[N]:None of explosion protected type
[1]:Position number marked on the nameplate
[A]:Aluminium alloy
EJC Differential Pressure Level Transmitter General Specifications
www.bcstgroup.com 33 BCST Group Co.,Ltd
EJCLT Differential Pressure Level
Transmitter
1 Application
The differential pressure level transmitter EJCLT is
suitable to measure liquid, gas, or steam flow as well
as liquid level, density and pressure. EJCLT outputs
a 4~20mADC signal corresponding to the measured
differential pressure. Its highly accurate and stable
sensor can also measure the static pressure which
can be shown on the integral indicator or remotely
monitored via HART communications. Other key
features include quick response, remote set-up using
communications, self-diagnostics and optional status
output for pressure high/low alarm. The range Limits
is 0—1kPa ~ 2MPa, The flange’s working pressure
are 1.6/4MPa,6.4MPa,10MPa,150psi,300psi or
600psi.
2 Operation Theory and Structure
EJCLT differential pressure level transmitter is
composed of EJCLT series differential pressure
transmitter and the welding installation level flange.
The operation theory is the same as EJCLT series
differential pressure transmitter (consult EJCLT
series differential pressure transmitter general
specifications), Only the high pressure side of
pressure transmission path is different. The pressure
Loaded in the high side, pass from the isolation
diaphragm and silicone oil in the flange to the sensor.
3 Input
Measured value: Differential pressure, Level
Measuring range
Lower range value: -100% to +100% of the
URL(continuously adjustable)
Upper range value: Up to 100% of the
URL(continuously adjustable)
Spans
Table 1:Span code, measuring range and SWP
Span
code
Measuring range
SWP(Max)
Min Max
B 1kPa 6kPa
The flange’s
working pressure
C 4kPa 40kPa
D 25kPa 250kPa
F 200kPa 3MPa
Table 2: Flange and minimum measuring range
The minimum measuring range of the differential
pressure Level transmitter should be the larger value of
the minimum range of table 1 and table 2.The adjusted
span must not be lower than the minimum range.
4 Output
Output signal
Two wire 4~20mADC output with digital
communications, linear or square root programmable.
HART FSK protocol are superimposed on the 4~20
mADC signal. Output range: 3.9 mA to 20.5 mA.
Failure Alarm (the mode can be selected)
Low Mode (min): 3.7 mA, High Mode (max): 21 mA
Flange Nominal
diameter
The minimum
measuring range
Bulge sealing
DN 50/2” 10kPa
DN 80/3” 2kPa
DN 4” 2kPa
Flat sealing
DN 50/2” 16kPa
DN 80/3” 2kPa
DN 4” 2kPa
EJC Differential Pressure Level Transmitter General Specifications
www.bcstgroup.com 34 BCST Group Co.,Ltd
No Mode (hold): Keep the effective value before the
fault. Note: The standard setting of failure alarm is High
Mode.
5 Response Time
The amplifier damping constant is 0.1 sec; The sensor
and flange’s damping constant is 0.2~3 sec, it depends
on the range and range compression ratio. Amplifier
damping time constant is adjustable from 0.1 to 60 sec
by software and added to response time.
6 General conditions
6.1 Installation conditions
The transmitter can be directly flanged in any position.
Preferably in such a position that the process flange
axes are vertical. Deviations from this can cause a shift
in the zero, which can be corrected. The electronic
housing can be rotated through 360°and can be fixed
in any position. A stop prevents the housing being
turned too far.
6.2 Ambient conditions
Ambient temperature
Min:depends on the fill fluid
Max:85℃
-20~65℃,with LCD-indicator
Storage temperature/transport temperature
Min:depends on the fill fluid
Max:85℃
Humidity:0~100%
Shock resistant: Acceleration:50g,Duration:11ms
Vibration resistance: 500Hz on 2g
Electromagnetic Compatibility (EMC)
Look the EMC Performance Table 3
6.3 Process conditions
Temperature limits:-30~180℃
Pressure limits: From 3.5kPa abs. to working
pressure. Proof pressure up to 1.5-times the nominal
pressure simultaneously on both sides of the
transmitter admissible.
Flange working pressure
ANSI:150psi~600psi
DIN: PN 1.6MPa~PN 10MPa
One-sided overload: One-sided overload up to the
rated pressure. Possibly occurring zero offsets can be
corrected.
Weight:DN 50/2”about 7~10kg;DN 80/3” about 8~
11kg;DN 4” about 9~12kg
Explosion Protected Type
NEPSI / ATEX: Ex dⅡC T6
NEPSI / ATEX: Ex iaⅡC T4
Amb. Temp.: -40℃~65℃
6.4 Supply & Load Requirements
24VDC supply, R≤(Us-12V)/Imax kΩ, Imax=23 mA.
Maximum voltage limited: 42VDC, Minimum voltage
limited: 12VDC, 15VDC(with LCD display)
230Ω to 600Ω for digital communication
Wetted Parts Materials
Flange: 316 stainless steel
Isolating Diaphragm:316L stainless steel / Hastelloy
C/FEP or PFA plated on
316L/Tantalum
Nuts and Bolts: 304 stainless steel
Process Connector: 316 stainless steel
Fill fluid: Silicone oil/ Vegetable oil
Process Connector Gasket:Perbunan(NBR)/Viton
(FKM)/Teflon(PTFE)
Amplifier Housing: Aluminum with epoxy resin coat
Housing Gasket: Perbunan(NBR)
Name plate and tag:304 stainless steel
Degrees of Protection: IP67
Electrical Connection
The electrical connection is made via cable entry
M20x1.5.The screw terminals are suitable for wire
cross-sections up to 2.5mm2
.
Process Connection
Flange with fixing thread 7/16-20 UNF and 1/4-18 NPT
female thread on both sides. The level flange comply
with the ANSI standard or DIN standards.
EJC Differential Pressure Level Transmitter General Specifications
www.bcstgroup.com 35 BCST Group Co.,Ltd
Table 3 : EMC Performance Table
Items Test items Basic standards Test conditions
Performance
Level
1 Radiated interference (Housing) GB/T 9254-2008 30MHz~1000MHz OK
2
Conducted interference(DC
power port)
GB/T 9254-2008 0.15MHz~30MHz OK
3
Electrostatic Discharge (ESD)
Immunity
GB/T 17626.2-2006
4kV(Line)
8kV(Air)
B
4
RF electromagnetic field
immunity
GB/T 17626.3-2006 10V/m (80MHz~1GHz) A
5
Frequency magnetic field
immunity
GB/T 17626.8-2006 30A/m A
6
Electrical Fast Transient Burst
Immunity
GB/T 17626.4-2008 2kV(5/50ns,5kHz) B
7 Surge Immunity GB/T 17626.5-2008
0.5kV(line to line)
1kV(line to ground)
(1.2us/50us)
B
8
Conducted interference
immunity induced by RF field
GB/T 17626.6-2008 3V (150KHz~80MHz) A
Note:(1)Performance level A description: The technical specifications within the limits of normal performance.
(2)Performance level B description: Temporary reduction or loss of functionality or performance, it can restore
itself. The actual operating conditions, storage, and data will not be changed.
DIMENSIONS Unit : mm
EJC Differential Pressure Level Transmitter General Specifications
www.bcstgroup.com 36 BCST Group Co.,Ltd
Table 4: Level flange dimensions
Nominal diameter
Working
pressure
ΦD ΦK
Φd1 Φd2
Φd3 t b Bolt
Bulge
seal
Flat
seal
DN 50 PN1.6/4MPa 165 125 48.3 57 102 3+0.5
20 4 M16
(Sealing DIN 2526E) PN 6.4MPa 18 135 48.3 57 102 3+0.5
26 4 M20
(Flange DIN 2501) PN 10MPa 195 145 48.3 57 102 3+0.5
28 4 M20
DN 80 PN1.6/4MPa 200 160 76 75 138 3+0.5
24 8 M16
(Sealing DIN 2526E) PN 6.4MPa 215 170 76 75 138 3+0.5
28 8 M20
(Flange DIN 2501) PN 10MPa 230 180 76 75 138 3+0.5
32 8 M24
DN 2"
(ANSI B 16.5 RF)
150psi 152.4 120.6 48.3 57 92.1 3+0.5
17.4 4 M18
300psi 165.1 127.0 48.3 57 92.1 3+0.5
20.6 8 M18
600psi 165.1 127.0 48.3 57 92.1 6.35 31.75 8 M18
DN 3"
(ANSI B 16.5 RF)
150psi 190.5 152.4 76 75 127 3+0.5
22.2 4 M16
300psi 209.5 168.3 76 75 127 3+0.5
27.0 8 M20
600psi 209.5 168.3 76 75 127 6.35 38.05 8 M20
DN 4“ 150psi 229 191 89 89 157 3+0.5
30 8 M18
(ANSI B 16.5 RF) 300psi 255 200 89 89 157 3+0.5
32 8 M18
7 Terminal Configuration
Note:Quick interface functionally equivalent to the signal terminal
8 Process Connections Description
EJC Differential Pressure Level Transmitter General Specifications
www.bcstgroup.com 37 BCST Group Co.,Ltd
9 Model and suffix codes [1]
Level flange sealing device selection of the differential pressure Level transmitter EJCLT
10 Flange sealing device
LT- Level flange sealing, no capillary ,⊕ Side
20 Process connection, Flange and diaphragm material
A DN50 DIN 2501 E DN2526 316L stainless steel
B DN50 DIN 2501 E DN2526 Hastelloy C
C DN50 DIN 2501 E DN2526 Tantalum
H DN80 DIN 2501 E DN2526 316L stainless steel
I DN80 DIN 2501 E DN2526 Hastelloy C
G DN80 DIN 2501 E DN2526 Tantalum
D DN2″ANSI B 16.5 RF ANSI B 16.5 316L stainless steel
E DN2″ANSI B 16.5 RF ANSI B 16.5 Hastelloy C
F DN2″ANSI B 16.5 RF ANSI B 16.5 Tantalum
K DN3″ANSI B 16.5 RF ANSI B 16.5 316L stainless steel
L DN3″ANSI B 16.5 RF ANSI B 16.5 Hastelloy C
M DN3″ANSI B 16.5 RF ANSI B 16.5 Tantalum
N DN4″ANSI B 16.5 RF ANSI B 16.5 316L stainless steel
O DN4″ANSI B 16.5 RF ANSI B 16.5 Hastelloy C
P DN4″ANSI B 16.5 RF ANSI B 16.5 Tantalum
30 Working pressure
1 PN 1MPa/4MPa DIN 2501
2 PN 6.4MPa DIN 2501
3 PN 10MPa DIN 2501
6 150# ANSI B 16.5
7 300# ANSI B 16.5
8 600# ANSI B 16.5(not including DN4″ANSI B 16.5)
40 Flange sealing type
F Flat sealing
H Bulge sealing,316L stainless steel,extended diaphragm seal 50mm
I Bulge sealing,316L stainless steel,extended diaphragm seal 100mm
G Bulge sealing,316L stainless steel,extended diaphragm seal 150mm
L Bulge sealing,Hastelloy C, extended diaphragm seal 50mm
M Bulge sealing,Hastelloy C, extended diaphragm seal 100mm
N Bulge sealing,Hastelloy C, extended diaphragm seal 150mm
50 Fill fluid
S Silicone oil -40~200℃
V Vegetable oil 0~250℃
60 Diaphragm Protection
N None
1 FEP plated on 316L, ≤180℃
2 PFA plated on 316L, ≤260℃
3 PTFE coated on 316L[2]
, ≤200℃
Note 1:Before level flange sealing device selection, the selection of the EJCLT differential pressure transmitter should
EJC Differential Pressure Level Transmitter General Specifications
www.bcstgroup.com 38 BCST Group Co.,Ltd
be completed, and selected L option in line 60 of the in EJCLT options table;
Note 2:The PTFE membrane(F4 membrane) posted on the diaphragm, it could be applied to the measurement of
negative pressure, but it applies only to the flat level flange.
Order example:
For example:EJCLT-AC2A1LNN111N1C
[3]
, LT-H1FSN
[A]:Reference Accuracy:±0.05%
[C]:Span:0-400Pa~40kPa(0-40~4000 mmH2O)
[2]:Static pressure sensor:10MPa
[A]:316L stainless steel diaphragm, Silicone oil fill fluid
[1]:Working pressure:16MPa
[L]:Level
[N]:Perbunan(NBR)process connector gasket
[N]:None
[1]:With 304 stainless steel mounting bracket
[1]:With stainless steel oval-shaped flange with 1/2 NPT female thread
[1]:With LCD display
[N]:None of explosion protected type
[1]:Position number marked on the nameplate
[C]:Chinese manual
[LT-]: Level flange sealing, no capillary ,⊕ Side
[H]:DN80 DIN 2501,E DN2526, 316L stainless steel
[1]:Working pressure PN 1MPa/4MPa DIN 2501
[F]:Flange sealing type is flat sealing
[S]:Fill fluid is silicone oil
[N]:Wetted flange diaphragm surface without special treatment
Note3:Differential pressure transmitter options see the EJCLT Series transmitter General Specifications;
Note4:The minimum measuring range of the differential pressure Level transmitter should be the larger value of the
minimum range of table 1 and table 2. The adjusted span must not be lower than the minimum range.
Note5:
When measuring pressure or static pressure <50kPa (absolute pressure), it requires special handling during the
manufacturing process to ensure that performance.
EJCRH/RL Remote seal differential pressure transmitter General Specifications
www.bcstgroup.com 39 BCST Group Co.,Ltd
EJCRH/RL Remote Seal Differential
Pressure Transmitter
1 Application
The remote seal differential pressure transmitter
EJCDP is suitable to measure liquid, gas, or steam
flow as well as liquid level, density and pressure.
EJCDP outputs a 4~20mADC signal corresponding to
the measured differential pressure. Its highly
accurate and stable sensor can also measure the
static pressure which can be shown on the integral
indicator or remotely monitored via HART
communications. Other key features include quick
response, remote set-up using communications,
self-diagnostics and optional status output for
pressure high/low alarm. The range Limits is
0—1kPa~2MPa, The flange’s working pressure are
1.6/4MPa,6.4MPa,10MPa,150psi,300psi or 600psi.
2 Operation Theory and Structure
EJCDP remote seal differential pressure transmitter
is composed of EJCDP series differential pressure
transmitter and the welding installation remote seal
flange. The operation theory is the same as EJCDP
series differential pressure transmitter (see EJCDP
series differential pressure transmitter general
specifications), Only the pressure transmission path
is different. The pressure loaded in the high or low
side, pass from the isolation diaphragm and silicone
oil in the flange to the sensor.
3 Input
Measured value: Differential pressure, Level
Measuring range
Lower range value: -100% to +100% of the
URL(continuously adjustable)
Upper range value: Up to 100% of the
URL(continuously adjustable)
Spans
Table1: Span code, measuring range and SWP
Span
code
Measuring range
SWP(Max)
Min Max
B 1kPa 6kPa
The flange’s working
pressure
C 4kPa 40kPa
D 25kPa 250kPa
F 200kPa 3MPa
Table 2: Flange and minimum measuring range
The minimum measuring range of the remote seal
differential pressure transmitter should be the larger
value of the minimum range of table 1 and table 2.The
adjusted span must not be lower than the minimum
range.
4 Output
Output signal
Two wire 4~20mADC output with digital
communications, linear or square root programmable.
Flange
Nominal
diameter
The minimum measuring
range
one flange two flange
Flat
sealing
DN 50/2” 10kPa 10kPa
DN 80/3” 6kPa 2kPa
DN 4” 6kPa 2kPa
Bulge
sealing
DN 50/2” 16kPa 16kPa
DN 80/3” 6kPa 2kPa
DN 4” 6kPa 2kPa
EJCRH/RL Remote seal differential pressure transmitter General Specifications
www.bcstgroup.com 40 BCST Group Co.,Ltd
HART FSK protocol are superimposed on the 4~20
mADC signal. Output range: 3.9 mA to 20.5 mA.
Failure Alarm (the mode can be selected)
Low Mode (min): 3.7 mA, High Mode (max): 21 mA
No Mode (hold): Keep the effective value before the
fault. Note: The standard setting of failure alarm is High
Mode.
5 Response Time
The amplifier damping constant is 0.1 sec; The sensor
and flange’s damping constant is 0.2~3 sec, it depends
on the range and range compression ratio. Amplifier
damping time constant is adjustable from 0.1 to 60 sec
by software and added to response time.
6 General conditions
6.1 Installation conditions
The transmitter can be directly flanged in any position.
Preferably in such a position that the process flange
axes are vertical. Deviations from this can cause a shift
in the zero, which can be corrected. The electronic
housing can be rotated through 360°and can be fixed
in any position. A stop prevents the housing being
turned too far. The minimum bend radius of the
capillary of 75mm, is strictly prohibited winding!
6.2 Ambient conditions
Ambient temperature
Min:depends on the fill fluid
Max:85℃
-20~65℃,with LCD-indicator
Storage temperature/transport temperature
Min:depends on the fill fluid
Max:85℃
Humidity:0~100%
Shock resistant: Acceleration:50g,Duration:11ms
Vibration resistance: 500Hz on 2g
Electromagnetic Compatibility (EMC)
See the EMC Performance Table 4
6.3 Process conditions
Temperature limits:-30~400℃
Table 3: Fill fluid, temperature limits and the
working pressure range
Note : Beyond the above working temperature and
working pressure range should be pointed out, a
specially designed can be met the requirements.
Pressure limits: From 3.5kPa abs. to working
pressure. Proof pressure up to 1.5-times the nominal
pressure simultaneously on both sides of the
transmitter admissible.
Flange working pressure
ANSI:150psi~600psi
DIN: PN 1.6MPa~PN 10MPa
One-sided overload: One-sided overload up to the
rated pressure. Possibly occurring zero offsets can be
corrected.
Weight
One flange remote seal: DN 50/2”about 7~10kg;DN
80/3” about 8~11kg;DN 4” about 9~12kg;
Two flange remote seal: DN 50/2”about 10~16.5kg;
Fill fluid
Silicone
oil (S)
High temp.
silicone oil
(H)
Super high
temp.
silicone oil
(U)
Vegetable
oil (V)
Density
25℃
960
kg/m3
980
kg/m3
1020
kg/m3
937
kg/m3
Temp.
limits
-40~
200℃
-10~
350℃
-10~
400℃
0~
250℃
Temp. Working pressure range (kPa abs.)
20℃ >10 >10 >10 >25
100℃ >25 >25 >25 >50
150℃ >50 >50 >50 >75
200℃ >75 >75 >75 >100
250℃ >100 >100 >100
350℃ >100 >100
400℃ >100
EJCRH/RL Remote seal differential pressure transmitter General Specifications
www.bcstgroup.com 41 BCST Group Co.,Ltd
DN 80/3” about 12~18kg;DN 4” about 14~21kg.
Explosion Protected Type
NEPSI / ATEX: Ex dⅡC T6
NEPSI / ATEX: Ex iaⅡC T4
Amb. Temp.: -40℃~65℃
6.4 Supply & Load Requirements
24VDC supply, R≤(Us-12V)/Imax kΩ,
Imax=23 mA.
Maximum voltage limited: 42VDC,
Minimum voltage limited: 12VDC,
15VDC(with LCD display)
230Ω to 600Ω for digital communication
Wetted Parts Materials
Flange: 316 stainless steel
Isolating Diaphragm:316L stainless steel / Hastelloy
C/FEP or PFA plated on
316L/Tantalum
Nuts and Bolts: 304 stainless steel
Process Connector: 316 stainless steel
Fill fluid: Silicone oil/ Vegetable oil
Process Connector Gasket:Perbunan(NBR)/Viton
(FKM)/Teflon(PTFE)
Amplifier Housing: Aluminum with epoxy resin coat
Housing Gasket: Perbunan(NBR)
Name plate and tag:304 stainless steel
Degrees of Protection: IP67
Electrical Connection
The electrical connection is made via cable entry
M20x1.5.The screw terminals are suitable for wire
cross-sections up to 2.5mm2
.
Process Connection
Flange with fixing thread 7/16-20 UNF .The flange
comply with the ANSI standard or DIN standards.
————————————————————————————————————————————
Table 4 : EMC Performance Table
Items Test items Basic standards Test conditions
Performance
Level
1 Radiated interference (Housing) GB/T 9254-2008 30MHz~1000MHz OK
2
Conducted interference(DC
power port)
GB/T 9254-2008 0.15MHz~30MHz OK
3
Electrostatic Discharge (ESD)
Immunity
GB/T 17626.2-2006
4kV(Line)
8kV(Air)
B
4
RF electromagnetic field
immunity
GB/T 17626.3-2006 10V/m (80MHz~1GHz) A
5
Frequency magnetic field
immunity
GB/T 17626.8-2006 30A/m A
6
Electrical Fast Transient Burst
Immunity
GB/T 17626.4-2008 2kV(5/50ns,5kHz) B
7 Surge Immunity GB/T 17626.5-2008
0.5kV(line to line)
1kV(line to ground)
(1.2us/50us)
B
8
Conducted interference
immunity induced by RF field
GB/T 17626.6-2008 3V (150KHz~80MHz) A
Note:(1)Performance level A description: The technical specifications within the limits of normal performance.
EJCRH/RL Remote seal differential pressure transmitter General Specifications
www.bcstgroup.com 42 BCST Group Co.,Ltd
(2)Performance level B description: Temporary reduction or loss of functionality or performance, it can restore
itself. The actual operating conditions, storage, and data will not be changed.
EJCRH/RL Remote seal differential pressure transmitter General Specifications
www.bcstgroup.com 43 BCST Group Co.,Ltd
7 DIMENSIONS Unit : mm
Figure 1 Two side flange remote seal device
Figure 2 One side flange remote seal device
Note:(1)The one side flange can be installed in the high or low pressure side of the transmitter ;
(2)The one or two side flange remote seal transmitter’s installation is the same way as the EJCDPseries
differential pressure transmitter
EJCRH/RL Remote seal differential pressure transmitter General Specifications
www.bcstgroup.com 44 BCST Group Co.,Ltd
Table 5: Remote seal flange dimensions
Nominal diameter
Working
pressure
ΦD ΦK
Φd1 Φd2
Φd3 t b Bolt
Bulge
seal
Flat
seal
DN 50 PN1.6/4MPa 165 125 48.3 57 102 3+0.5
20 4 M16
(Sealing DIN 2526E) PN 6.4MPa 18 135 48.3 57 102 3+0.5
26 4 M20
(Flange DIN 2501) PN 10MPa 195 145 48.3 57 102 3+0.5
28 4 M20
DN 80 PN1.6/4MPa 200 160 76 75 138 3+0.5
24 8 M16
(Sealing DIN 2526E) PN 6.4MPa 215 170 76 75 138 3+0.5
28 8 M20
(Flange DIN 2501) PN 10MPa 230 180 76 75 138 3+0.5
32 8 M24
DN 2"
(ANSI B 16.5 RF)
150psi 152.4 120.6 48.3 57 92.1 3+0.5
17.4 4 M18
300psi 165.1 127.0 48.3 57 92.1 3+0.5
20.6 8 M18
600psi 165.1 127.0 48.3 57 92.1 6.35 31.75 8 M18
DN 3"
(ANSI B 16.5 RF)
150psi 190.5 152.4 76 75 127 3+0.5
22.2 4 M16
300psi 209.5 168.3 76 75 127 3+0.5
27.0 8 M20
600psi 209.5 168.3 76 75 127 6.35 38.05 8 M20
DN 4“ 150psi 229 191 89 89 157 3+0.5
30 8 M18
(ANSI B 16.5 RF) 300psi 255 200 89 89 157 3+0.5
32 8 M18
Figure 3 Two side flange remote seal of threaded mount device
EJCRH/RL Remote seal differential pressure transmitter General Specifications
www.bcstgroup.com 45 BCST Group Co.,Ltd
Figure 4 One side flange remote seal of threaded mount device
Note:(1)The one side flange can be installed in the high or low pressure side of the transmitter ;
(2)The one or two side flange remote seal transmitter’s installation is the same way as the EJCDPseries
differential pressure transmitter.
8 Terminal Configuration
Note:Quick interface functionally equivalent to the signal terminal
9 Process Connections Description of the no flange side
EJCRH/RL Remote seal differential pressure transmitter General Specifications
www.bcstgroup.com 46 BCST Group Co.,Ltd
10 Model and suffix codes[1]
1 Flange sealing device selection of the remote seal differential pressure transmitter RP1001
10 Flange sealing device
RH- With capillary ⊕side
RL- With capillary Θside
20 Process connection, Flange and diaphragm material
A DN50 DIN 2501 E DN2526 316L stainless steel
B DN50 DIN 2501 E DN2526 Hastelloy C
C DN50 DIN 2501 E DN2526 Tantalum
H DN80 DIN 2501 E DN2526 316L stainless steel
I DN80 DIN 2501 E DN2526 Hastelloy C
G DN80 DIN 2501 E DN2526 Tantalum
D DN2″ANSI B 16.5 RF ANSI B 16.5 316L stainless steel
E DN2″ANSI B 16.5 RF ANSI B 16.5 Hastelloy C
F DN2″ANSI B 16.5 RF ANSI B 16.5 Tantalum
K DN3″ANSI B 16.5 RF ANSI B 16.5 316L stainless steel
L DN3″ANSI B 16.5 RF ANSI B 16.5 Hastelloy C
M DN3″ANSI B 16.5 RF ANSI B 16.5 Tantalum
N DN4″ANSI B 16.5 RF ANSI B 16.5 316L stainless steel
O DN4″ANSI B 16.5 RF ANSI B 16.5 Hastelloy C
P DN4″ANSI B 16.5 RF ANSI B 16.5 Tantalum
30 Working pressure
1 PN 1MPa/4MPa DIN 2501
2 PN 6.4MPa DIN 2501
3 PN 10MPa DIN 2501
6 150psi ANSI B 16.5
7 300psi ANSI B 16.5
8 600psi ANSI B 16.5(not including DN4″ANSI B 16.5)
40 Process connections
F Flat sealing
H Bulge sealing,316L stainless steel,extended diaphragm seal 50mm
I Bulge sealing,316L stainless steel,extended diaphragm seal 100mm
G Bulge sealing,316L stainless steel,extended diaphragm seal 150mm
L Bulge sealing,Hastelloy C, extended diaphragm seal 50mm
M Bulge sealing,Hastelloy C, extended diaphragm seal 100mm
N Bulge sealing,Hastelloy C, extended diaphragm seal 150mm
50 Fill fluid
S Silicone oil -40~200℃
H High temp. silicone oil -10~350℃
U Super high temp. silicone oil -10~400℃
V Vegetable oil 0~250℃
60 Capillary Length
1 1m
2 2m
EJCRH/RL Remote seal differential pressure transmitter General Specifications
www.bcstgroup.com 47 BCST Group Co.,Ltd
3 3m
4 4m
5 5m
6 6m
8 8m
A 10m
S Special length
70 Capillary component characteristics
N
P
None
With PVC protective coating capillary
80 Diaphragm Protection
N None
1 FEP plated on 316L, ≤180℃
2 PFA plated on 316L, ≤260℃
3 PTFE coated on 316L[2]
, ≤200℃
Note 1: Before flange sealing device selection, the selection of the EJCDPdifferential pressure transmitter should be
completed, and selected R option in line 60 of the in EJCDPoptions table;
Note 2: The PTFE membrane(F4 membrane) posted on the diaphragm, it could be applied to the measurement of
negative pressure >50kPa, but it applies only to the flat level flange.
————————————————————————————————————————————————————
Order example:
For example: EJCDP-AC2A1LNN111N1C[3]
,
RH-H1FS4PN,
RL-H1FS4PN.
[A]:Reference Accuracy:±0.05%
[C]:Span:0-400Pa~40kPa(0-40~4000 mmH2O)
[2]:Static pressure sensor:10MPa
[A]:316L stainless steel diaphragm, Silicone oil fill fluid
[1]:Working pressure:16MPa
[L]:Level
[N]:Perbunan(NBR)process connector gasket
[N]:None
[1]:With 304 stainless steel mounting bracket
[1]:With stainless steel oval-shaped flange with 1/2 NPT
female thread
[1]:With LCD display
[N]:None of explosion protected type
[1]:Position number marked on the nameplate
[C]:Chinese manual
[RH-]:Flange sealing device of high side
[H]: DN80(DIN 2501),E DN2526, 316L stainless steel
diaphragm
[1]: Working pressure PN 1MPa/4MPa(DIN 2501)
[F]: Flange sealing type is flat sealing
[S]:[S]: Fill fluid is silicone oil
[4]: Capillary’s length is 4m
[P]: With PVC protective coating capillary
[N]: Diaphragm surface without special treatment
[RL-]:Flange sealing device of low side
[H]: DN80
(DIN 2501)
,E DN2526, 316L stainless steel
diaphragm
[1]: Working pressure PN 1MPa/4MPa(DIN 2501)
[F]: Flange sealing type is flat sealing
[S]:Fill fluid is silicone oil
[4]: Capillary’s length is 4m
[P]: With PVC protective coating capillary
[N]:Diaphragm surface without special treatment
Note 3:Differential pressure transmitter options see
the EJCDP Series transmitter general specifications;
Note 4:The minimum measuring range of the remote
seal differential pressure transmitter should be the
larger value of the minimum range of table 1 and table
2. The adjusted span must not be lower than the
minimum range.
Note 5:When measuring pressure or static pressure
<50kPa (absolute pressure), it requires special
handling during the manufacturing process to ensure
that performance.
EJCRH/RL Remote seal differential pressure transmitter General Specifications
www.bcstgroup.com 48 BCST Group Co.,Ltd
2 Threaded mount device remote seal of differential pressure transmitter EJCDP[6]
10 Flange sealing device
TH- With capillary ⊕side
TL- With capillary Θside
20 Diaphragm material
U 316L stainless steel
V Hastelloy C
W Tantalum
30 Flushing spare hole
1 None
0 Yes
40 Fill fluid
S Silicone oil -40~200℃
H High temp. silicone oil -10~350℃
U Super high temp. silicone oil -10~400℃
V Vegetable oil 0~250℃
50 Capillary Length
1 1m
2 2m
3 3m
4 4m
5 5m
6 6m
8 8m
S Special length
60 Capillary component characteristics
N None
P With PVC protective coating capillary
Note 6: Before flange sealing device selection, the selection of the EJCDPdifferential pressure transmitter should be
completed, and selected S option in line 60 of the in EJCDPoptions table;
————————————————————————————————————————————————————
For example: EJCDP-AC2A1LNN111N1C[7]
,
TH-U1S3N
[A]:Reference Accuracy:±0.05%
[C]:Span:0-400Pa~40kPa(0-40~4000 mmH2O)
[2]:Static pressure sensor:10MPa
[A]:316L stainless steel diaphragm, Silicone oil fill fluid
[1]:Working pressure:16MPa
[L]:Level
[N]:Perbunan(NBR)process connector gasket
[N]:None
[1]:With 304 stainless steel mounting bracket
[1]:With stainless steel oval-shaped flange with 1/2 NPT
female thread
[1]:With LCD display
[N]:None of explosion protected type
[1]:Position number marked on the nameplate
[C]:Chinese manual
[TH-] High side is threaded mount device remote seal
[U]:316L stainless steel diaphragm
[1]:No relief valves
[S]:Silicone oil fill fluid
[3]:Capillary’s length is 3m
[P]:With PVC protective coating capillary
Note 7: Content with note 3
Note 8: Content with note 4
Note 9: Content with note 5
EJCRN/S Remote Seal Gauge/Absolute Pressure Transmitter General Specifications
www.bcstgroup.com 48 BCST Group Co.,Ltd
EJCRN Remote Seal Gauge Pressure
Transmitter
EJCRS Remote Seal Absolute Pressure
Transmitter
1 Application
The remote seal gauge/absolute pressure transmitter
EJCRN/S is suitable to measure liquid, gas, or steam
flow as well as liquid level, density and pressure.
RP1001 outputs a 4~20mADC signal corresponding
to the measured gauge/absolute pressure. Other key
features include quick response, remote set-up using
communications, self-diagnostics and optional status
output for pressure high/low alarm. The range Limits
is 0—6kPa~25MPa, The flange’s working pressure
are 1.6/4MPa,6.4MPa,10MPa,150psi,300psi or
600psi.
2 Operation Theory and Structure
EJCRN/S remote seal gauge/absolute pressure
transmitter is composed of EJCRN/S series
gauge/absolute pressure transmitter and the welding
installation remote seal flange. The operation theory
is the same as EJCRN/S series gauge/absolute
pressure transmitter (see EJCRN/S series
gauge/absolute pressure transmitter general
specifications), Only the pressure transmission path
is different. The pressure loaded in the high or low
side, pass from the isolation diaphragm and silicone
oil in the flange to the sensor.
3 Input
Measured value: Gauge/absolute pressure, Level
Measuring range
Gauge pressure:
-100%URL to +100%URL
(continuously adjustable)
Absolute pressure:
0 to +100%URL(continuously adjustable)
Spans
Tanble1Span code, measuring range and SWP
Span
code
Measuring range
SWP(Max)
Min
C 6kPa 40kPa
The flange’s
working
pressure
D 25kPa 250kPa
F 30kPa 3MPa
G 1MPa 10MPa
H 2.1MPa 21MPa
I 4MPa 40MPa
L 6kPa abs. 40kPa abs.
M 25kPa abs. 250kPa abs.
O 30kPa abs. 3MPa abs.
Table 2: Flange and minimum measuring range
The minimum measuring range of the remote seal
Flange
Nominal
diameter
The min/max
measuring
range
The max
length of
capillary
Flat
sealing
DN 25/1” 10kPa/25MPa 10m
DN 50/2” 10kPa/10MPa 12m
DN 80/3” 6kPa/10MPa 16m
DN 4” 6kPa/3MPa 16m
Bulge
sealing
DN 50/2” 16kPa/10MPa 10m
DN 80/3” 6kPa/10MPa 16m
DN 4” 6kPa/3MPa 16m
threaded
mount
sealing
¢109mm 16kPa/25MPa 10m
EJCRN/S Remote Seal Gauge/Absolute Pressure Transmitter General Specifications
www.bcstgroup.com 49 BCST Group Co.,Ltd
gauge/absolute pressure transmitter should be the
larger value of the minimum range of table 1 and table
2.The adjusted span must not be lower than the
minimum range.
4 Output
Output signal
Two wire 4~20mADC output with digital
communications, linear or square root programmable.
HART FSK protocol are superimposed on the 4~20
mADC signal. Output range: 3.9 mA to 20.5 mA.
Failure Alarm (the mode can be selected)
Low Mode (min): 3.7 mA, High Mode (max): 21 mA
No Mode (hold): Keep the effective value before the
fault. Note: The standard setting of failure alarm is High
Mode.
5 Response Time
The amplifier damping constant is 0.1 sec; The sensor
and flange’s damping constant is 0.2~3 sec, it depends
on the range and range compression ratio. Amplifier
damping time constant is adjustable from 0.1 to 60 sec
by software and added to response time.
6 General conditions
6.1 Installation conditions
The transmitter can be directly flanged in any position.
Preferably in such a position that the process flange
axes are vertical. Deviations from this can cause a shift
in the zero, which can be corrected. The electronic
housing can be rotated through 360°and can be fixed
in any position. A stop prevents the housing being
turned too far. The minimum bend radius of the
capillary of 75mm, is strictly prohibited winding!
6.2 Ambient conditions
Ambient temperature
Min:depends on the fill fluid
Max:85℃
-20~65℃,with LCD-indicator
Storage temperature/transport temperature
Min:depends on the fill fluid
Max:85℃
Humidity:0~100%
Shock resistant: Acceleration:50g,Duration:11ms
Vibration resistance: 500Hz on 2g
Electromagnetic Compatibility (EMC)
See the EMC Performance Table 4
6.3 Process conditions
Temperature limits:-30~400℃
Table 3: Fill fluid, temperature limits and the
working pressure range
Note : Beyond the above working temperature and
working pressure range should be pointed out, a
specially designed can be met the requirements.
Pressure limits: From vacuum to working pressure.
Flange working pressure
ANSI:150psi~600psi
DIN: PN 1.6MPa~PN 10MPa
Weight
Fill fluid
Silicone
oil (S)
High
temp.
silicone oil
(H)
Super
high
temp.
silicone
oil (U)
Vegetable
oil (V)
Density
25℃
960
kg/m3
980
kg/m3
1020
kg/m3
937
kg/m3
Temp.
limits
-40~
200℃
-10~
350℃
-10~
400℃
0~
250℃
Temp. Working pressure range (kPa abs.)
20℃ >10 >10 >10 >25
100℃ >25 >25 >25 >50
150℃ >50 >50 >50 >75
200℃ >75 >75 >75 >100
250℃ >100 >100 >100
350℃ >100 >100
400℃ >100
EJCRN/S Remote Seal Gauge/Absolute Pressure Transmitter General Specifications
www.bcstgroup.com 50 BCST Group Co.,Ltd
DN 50/2”about 7~10kg;DN 80/3” about 8~11kg;DN
4” about 9~12kg;
Explosion Protected Type
NEPSI / ATEX: Ex dⅡC T6
NEPSI / ATEX: Ex iaⅡC T4
Amb. Temp.: -40℃~65℃
6.4 Supply & Load Requirements
24VDC supply, R≤(Us-12V)/Imax kΩ,
Imax=23 mA.
Maximum voltage limited: 42VDC,
Minimum voltage limited: 12VDC,
15VDC(with LCD display)
230Ω to 600Ω for digital communication
Wetted Parts Materials
Flange: 316 stainless steel
Isolating Diaphragm:316L stainless steel / Hastelloy
C/FEP or PFA plated on
316L/Tantalum
Nuts and Bolts: 304 stainless steel
Process Connector: 316 stainless steel
Fill fluid: Silicone oil/ Vegetable oil
Process Connector Gasket:Perbunan(NBR)/Viton
(FKM)/Teflon(PTFE)
Amplifier Housing: Aluminum with epoxy resin coat
Housing Gasket: Perbunan(NBR)
Name plate and tag:304 stainless steel
Degrees of Protection: IP67
Electrical Connection
The electrical connection is made via cable entry
M20x1.5.The screw terminals are suitable for wire
cross-sections up to 2.5mm2
.
Process Connection
The flange comply with the ANSI standard or DIN
standards.
————————————————————————————————————————————
Table 4 : EMC Performance Table
Items Test items Basic standards Test conditions
Performance
Level
1 Radiated interference (Housing) GB/T 9254-2008 30MHz~1000MHz OK
2
Conducted interference(DC
power port)
GB/T 9254-2008 0.15MHz~30MHz OK
3
Electrostatic Discharge (ESD)
Immunity
GB/T 17626.2-2006
4kV(Line)
8kV(Air)
B
4
RF electromagnetic field
immunity
GB/T 17626.3-2006 10V/m (80MHz~1GHz) A
5
Frequency magnetic field
immunity
GB/T 17626.8-2006 30A/m A
6
Electrical Fast Transient Burst
Immunity
GB/T 17626.4-2008 2kV(5/50ns,5kHz) B
7 Surge Immunity GB/T 17626.5-2008
0.5kV(line to line)
1kV(line to ground)
(1.2us/50us)
B
8
Conducted interference
immunity induced by RF field
GB/T 17626.6-2008 3V (150KHz~80MHz) A
Note:(1)Performance level A description: The technical specifications within the limits of normal performance.
(2)Performance level B description: Temporary reduction or loss of functionality or performance, it can restore
itself. The actual operating conditions, storage, and data will not be changed.
EJCRN/S Remote Seal Gauge/Absolute Pressure Transmitter General Specifications
www.bcstgroup.com 51 BCST Group Co.,Ltd
7 DIMENSIONS Unit : mm
Figure 1 Gauge/Absolute remote seal device (RS Type)
Figure 2 Gauge/Absolute remote seal device without capillary (RN Type)
EJCRN/S Remote Seal Gauge/Absolute Pressure Transmitter General Specifications
www.bcstgroup.com 52 BCST Group Co.,Ltd
Table 5: Remote seal flange dimensions
Nominal diameter
Working
pressure
ΦD ΦK
Φd1 Φd2
Φd3 t b Bolt
Bulge
seal
Flat
seal
DN 50 PN1.6/4MPa 165 125 48.3 57 102 3+0.5
20 4 M16
(Sealing DIN 2526E) PN 6.4MPa 18 135 48.3 57 102 3+0.5
26 4 M20
(Flange DIN 2501) PN 10MPa 195 145 48.3 57 102 3+0.5
28 4 M20
DN 80 PN1.6/4MPa 200 160 76 75 138 3+0.5
24 8 M16
(Sealing DIN 2526E) PN 6.4MPa 215 170 76 75 138 3+0.5
28 8 M20
(Flange DIN 2501) PN 10MPa 230 180 76 75 138 3+0.5
32 8 M24
DN 2"
(ANSI B 16.5 RF)
150psi 152.4 120.6 48.3 57 92.1 3+0.5
17.4 4 M18
300psi 165.1 127.0 48.3 57 92.1 3+0.5
20.6 8 M18
600psi 165.1 127.0 48.3 57 92.1 6.35 31.75 8 M18
DN 3"
(ANSI B 16.5 RF)
150psi 190.5 152.4 76 75 127 3+0.5
22.2 4 M16
300psi 209.5 168.3 76 75 127 3+0.5
27.0 8 M20
600psi 209.5 168.3 76 75 127 6.35 38.05 8 M20
DN 4“ 150psi 229 191 89 89 157 3+0.5
30 8 M18
(ANSI B 16.5 RF) 300psi 255 200 89 89 157 3+0.5
32 8 M18
Figure 3 Internal diaphragm remote seal (US Type)
EJCRN/S Remote Seal Gauge/Absolute Pressure Transmitter General Specifications
www.bcstgroup.com 53 BCST Group Co.,Ltd
Figure 4 Internal diaphragm remote seal without capillary (UN Type)
Table 6 Internal diaphragm remote seal flange dimensions (DIN 2501)
DN PN
Dimensions, mm Weight
kg
D K d4 b f H d2 G2
25 1MPa/4MPa 115 85 68 22 2 - 14 - 1.5
25
6.3MPa/10MPa 140 100 68 24 2 52 - 4×M16 3.2
16MPa 140 100 68 24 2 52 - 4×M16 3.6
25MPa 150 105 68 28 2 96 - 4×M20 4
Table 7 Internal diaphragm remote seal flange dimensions (ANSI B 16.5)
DN psi
Dimensions, mm Weight
kg
D K d2 d4 b f H G2UNC
1"
150 110 79.5 16 51 22 2 - - 1.4
300 125 89 20 51 22 2 - - 1.7
1"
600 125 89 - 51 25 7 53 4×5/8” 3.6
1500 150 101.5 - 51 36 7 64 4×7/8” 4.0
EJCRN/S Remote Seal Gauge/Absolute Pressure Transmitter General Specifications
www.bcstgroup.com 54 BCST Group Co.,Ltd
Figure 5 Remote seal of threaded mount device (TS Type)
8 Terminal Configuration
Figure 6 Electrical connection diagram
Note:Quick interface functionally equivalent to the signal terminal
EJCRN/S Remote Seal Gauge/Absolute Pressure Transmitter General Specifications
www.bcstgroup.com 55 BCST Group Co.,Ltd
9 Model and suffix codes[1]
1 Flange sealing device selection of the remote seal gauge/absolute pressure transmitter EJCRN/S
10 Flange sealing device
RN- Without capillary
RS- With capillary
20 Process connection, Flange and diaphragm material
A DN50 DIN 2501 E DN2526 316L stainless steel
B DN50 DIN 2501 E DN2526 Hastelloy C
C DN50 DIN 2501 E DN2526 Tantalum
H DN80 DIN 2501 E DN2526 316L stainless steel
I DN80 DIN 2501 E DN2526 Hastelloy C
G DN80 DIN 2501 E DN2526 Tantalum
D DN2″ANSI B 16.5 RF ANSI B 16.5 316L stainless steel
E DN2″ANSI B 16.5 RF ANSI B 16.5 Hastelloy C
F DN2″ANSI B 16.5 RF ANSI B 16.5 Tantalum
K DN3″ANSI B 16.5 RF ANSI B 16.5 316L stainless steel
L DN3″ANSI B 16.5 RF ANSI B 16.5 Hastelloy C
M DN3″ANSI B 16.5 RF ANSI B 16.5 Tantalum
N DN4″ANSI B 16.5 RF ANSI B 16.5 316L stainless steel
O DN4″ANSI B 16.5 RF ANSI B 16.5 Hastelloy C
P DN4″ANSI B 16.5 RF ANSI B 16.5 Tantalum
30 Working pressure
1 PN 1MPa/4MPa DIN 2501
2 PN 6.4MPa DIN 2501
3 PN 10MPa DIN 2501
6 150psi ANSI B 16.5
7 300psi ANSI B 16.5
8 600psi ANSI B 16.5(not including DN4″ANSI B 16.5)
40 连接形式
F Flat sealing
H Bulge sealing,316L stainless steel,extended diaphragm seal 50mm
I Bulge sealing,316L stainless steel,extended diaphragm seal 100mm
G Bulge sealing,316L stainless steel,extended diaphragm seal 150mm
L Bulge sealing,Hastelloy C, extended diaphragm seal 50mm
M Bulge sealing,Hastelloy C, extended diaphragm seal 100mm
N Bulge sealing,Hastelloy C, extended diaphragm seal 150mm
50 Fill fluid
S Silicone oil -40~200℃
H High temp. silicone oil -10~350℃
U Super high temp. silicone oil -10~400℃
V Vegetable oil 0~250℃
60 Capillary Length
1 1m
2 2m
EJCRN/S Remote Seal Gauge/Absolute Pressure Transmitter General Specifications
www.bcstgroup.com 56 BCST Group Co.,Ltd
3 3m
4 4m
5 5m
6 6m
8 8m
A 10m
S Special length
70 Capillary component characteristics
N
P
None
With PVC protective coating capillary
80 Diaphragm Protection
N None
1 FEP plated on 316L, ≤180℃
2 PFA plated on 316L, ≤260℃
3 PTFE coated on 316L[2]
, ≤200℃
Note 1: Before flange sealing device selection, the selection of the EJCRN/S gauge/absolute pressure transmitter
should be completed, and selected R option in line 40 of the in EJCRN/S options table;
Note 2: The PTFE membrane(F4 membrane) posted on the diaphragm, it could be applied to the measurement of
negative pressure >50kPa, but it applies only to the flat level flange.
————————————————————————————————————————————————————
Order example:
For example: EJCBP-ACARNN1N1C[3],
RN-H1FS0PN。
[A]:Reference Accuracy:±0.05%
[C]:Span:0-400Pa~40kPa(0-40~4000 mmH2O)
[A]:316L stainless steel diaphragm, Silicone oil fill fluid
[R]:Remote seak
[N]:None
[N]:None
[1]:With LCD display
[N]:None of explosion protected type
[1]:Position number marked on the nameplate
[C]:Chinese manual
[RN-]:Flange sealing device without capillary
[H]:DN80(DIN 2501),E DN2526, 316L stainless steel
diaphragm
[1]: Working pressure PN 1MPa/4MPa(DIN 2501)
[F]: Flange sealing type is flat sealing
[S]: Fill fluid is silicone oil
[4]: Capillary’s length is 4m
[P]: With PVC protective coating capillary
[N]: Diaphragm surface without special treatment
Note 3:Gauge/absolute pressure transmitter options
see the EJCRN/S Series transmitter general
Specifications;
Note 4:The minimum measuring range of the remote
seal gauge/absolute pressure transmitter should be
the larger value of the minimum range of table 1 and
table 2. The adjusted span must not be lower than the
minimum range.
Note 5:When measuring pressure <50kPa (absolute
pressure), it requires special handling during the
manufacturing process to ensure that performance.
EJCRN/S Remote Seal Gauge/Absolute Pressure Transmitter General Specifications
www.bcstgroup.com 57 BCST Group Co.,Ltd
2 Selection of the Internal diaphragm remote seal gauge/absolute pressure transmitter EJCRN/S [6]
10 Flange sealing device
UN- Without capillary
US- With capillary
20 Process connection, Flange and diaphragm material
A DN25 DIN 2501 D DN2526 PN 1MPa/4MPa
B DN25 DIN 2501 D DN2526 PN 6.3MPa/10MPa
C DN25 DIN 2501 D DN2526 PN 16MPa
D DN25 DIN 2501 D DN2526 PN 25MPa
E DN1″ANSI B 16.5 RF ANSI B 16.5 150psi
F DN1″ANSI B 16.5 RF ANSI B 16.5 300psi
G DN1″ANSI B 16.5 RF ANSI B 16.5 600psi
H DN1″ANSI B 16.5 RF ANSI B 16.5 1500psi
30 Fill fluid
S Silicone oil -40~200℃
H High temp. silicone oil -10~350℃
V Vegetable oil 0~250℃
40 Capillary Length
1 1m
2 2m
3 3m
4 4m
5 5m
6 6m
S Special length
50 Capillary component characteristics
N
P
None
With PVC protective coating capillary
Note 6: Before flange sealing device selection, the selection of the EJCRN/S gauge/absolute pressure transmitter
should be completed, and selected R option in line 40 of the in EJCRN/S options table.
————————————————————————————————————————————————————
Order example:
For example: EJCBP-ACARNN1N1C[3]
,
UN-AS
[A]:Reference Accuracy:±0.05%
[C]:Span:0-400Pa~40kPa(0-40~4000 mmH2O)
[A]:316L stainless steel diaphragm, Silicone oil fill fluid
[R]:Remote seak
[N]:None
[N]:None
[1]:With LCD display
[N]:None of explosion protected type
[1]:Position number marked on the nameplate
[C]:Chinese manual
[UN-]: Internal diaphragm remote seal,
without capillary
[A]:DN25(DIN 2501)
,D DN2526,
Working pressure PN 1MPa/4MPa
[S]:Fill fluid is silicone oil
Note 7:Content with note 3
Note 8:Content with note 4
Note 9:Content with note 5
High accuracy ejc hart pressure transmitter bcst
High accuracy ejc hart pressure transmitter bcst
High accuracy ejc hart pressure transmitter bcst
High accuracy ejc hart pressure transmitter bcst
High accuracy ejc hart pressure transmitter bcst
High accuracy ejc hart pressure transmitter bcst
High accuracy ejc hart pressure transmitter bcst
High accuracy ejc hart pressure transmitter bcst
High accuracy ejc hart pressure transmitter bcst
High accuracy ejc hart pressure transmitter bcst
High accuracy ejc hart pressure transmitter bcst
High accuracy ejc hart pressure transmitter bcst
High accuracy ejc hart pressure transmitter bcst
High accuracy ejc hart pressure transmitter bcst
High accuracy ejc hart pressure transmitter bcst
High accuracy ejc hart pressure transmitter bcst
High accuracy ejc hart pressure transmitter bcst
High accuracy ejc hart pressure transmitter bcst
High accuracy ejc hart pressure transmitter bcst
High accuracy ejc hart pressure transmitter bcst
High accuracy ejc hart pressure transmitter bcst

More Related Content

What's hot

Ria46 endress+hauser datasheet-field meter
Ria46 endress+hauser datasheet-field meterRia46 endress+hauser datasheet-field meter
Ria46 endress+hauser datasheet-field meterENVIMART
 
Testo 521 datasheet 2012
Testo 521 datasheet 2012Testo 521 datasheet 2012
Testo 521 datasheet 2012Testo Limited
 
Omnigrad m tr10 endress+hauser datasheet-modular rtd assembly temperature
Omnigrad m tr10 endress+hauser datasheet-modular rtd assembly temperatureOmnigrad m tr10 endress+hauser datasheet-modular rtd assembly temperature
Omnigrad m tr10 endress+hauser datasheet-modular rtd assembly temperatureENVIMART
 
Vapour pressure-model-1354 atac
Vapour pressure-model-1354 atacVapour pressure-model-1354 atac
Vapour pressure-model-1354 atacEuropean Tech Serv
 
WirelessHART Gas Detector for Toxic and Combustible Gas
WirelessHART Gas Detector for Toxic and Combustible GasWirelessHART Gas Detector for Toxic and Combustible Gas
WirelessHART Gas Detector for Toxic and Combustible GasMiller Energy, Inc.
 
Magnetrol TA2 Thermal Mass Flow Meter for Flare Gas Applications
Magnetrol TA2 Thermal Mass Flow Meter for Flare Gas ApplicationsMagnetrol TA2 Thermal Mass Flow Meter for Flare Gas Applications
Magnetrol TA2 Thermal Mass Flow Meter for Flare Gas ApplicationsMiller Energy, Inc.
 
Rbef e mini inductive magnetic flow meter-2017-catalog
Rbef e mini  inductive magnetic flow meter-2017-catalogRbef e mini  inductive magnetic flow meter-2017-catalog
Rbef e mini inductive magnetic flow meter-2017-catalogjessy Lee RB Flowmeter
 
Omnigrad s taf11, taf12x, taf16 endress+hauser datasheet-high temperature ass...
Omnigrad s taf11, taf12x, taf16 endress+hauser datasheet-high temperature ass...Omnigrad s taf11, taf12x, taf16 endress+hauser datasheet-high temperature ass...
Omnigrad s taf11, taf12x, taf16 endress+hauser datasheet-high temperature ass...ENVIMART
 
Omnigrad m tr44 45 endress+hauser datasheet-hygienic, modular rtd assembly-te...
Omnigrad m tr44 45 endress+hauser datasheet-hygienic, modular rtd assembly-te...Omnigrad m tr44 45 endress+hauser datasheet-hygienic, modular rtd assembly-te...
Omnigrad m tr44 45 endress+hauser datasheet-hygienic, modular rtd assembly-te...ENVIMART
 
Thermal analysis
Thermal analysisThermal analysis
Thermal analysislabmen1998
 
RBEF-E Mini Inductive Magnetic Flow Meter-2017-catalog
RBEF-E Mini  Inductive Magnetic Flow Meter-2017-catalogRBEF-E Mini  Inductive Magnetic Flow Meter-2017-catalog
RBEF-E Mini Inductive Magnetic Flow Meter-2017-catalogjessy Lee RB Flowmeter
 
Current To Pneumatic Converter for Process Control
Current To Pneumatic Converter for Process ControlCurrent To Pneumatic Converter for Process Control
Current To Pneumatic Converter for Process ControlClassic Controls, Inc.
 
Ultrasonic flow meter catalog
Ultrasonic flow meter catalogUltrasonic flow meter catalog
Ultrasonic flow meter catalogKevin Yang
 
ABB MagMaster - Flow Meter & End to End Testing Procedure
ABB MagMaster - Flow Meter & End to End Testing ProcedureABB MagMaster - Flow Meter & End to End Testing Procedure
ABB MagMaster - Flow Meter & End to End Testing ProcedureDavid List
 
Yokogawa Differential Pressure Transmitter
Yokogawa Differential Pressure TransmitterYokogawa Differential Pressure Transmitter
Yokogawa Differential Pressure TransmitterMiller Energy, Inc.
 

What's hot (20)

Ria46 endress+hauser datasheet-field meter
Ria46 endress+hauser datasheet-field meterRia46 endress+hauser datasheet-field meter
Ria46 endress+hauser datasheet-field meter
 
Testo 521 datasheet 2012
Testo 521 datasheet 2012Testo 521 datasheet 2012
Testo 521 datasheet 2012
 
Omnigrad m tr10 endress+hauser datasheet-modular rtd assembly temperature
Omnigrad m tr10 endress+hauser datasheet-modular rtd assembly temperatureOmnigrad m tr10 endress+hauser datasheet-modular rtd assembly temperature
Omnigrad m tr10 endress+hauser datasheet-modular rtd assembly temperature
 
Vapour pressure-model-1354 atac
Vapour pressure-model-1354 atacVapour pressure-model-1354 atac
Vapour pressure-model-1354 atac
 
WirelessHART Gas Detector for Toxic and Combustible Gas
WirelessHART Gas Detector for Toxic and Combustible GasWirelessHART Gas Detector for Toxic and Combustible Gas
WirelessHART Gas Detector for Toxic and Combustible Gas
 
Magnetrol TA2 Thermal Mass Flow Meter for Flare Gas Applications
Magnetrol TA2 Thermal Mass Flow Meter for Flare Gas ApplicationsMagnetrol TA2 Thermal Mass Flow Meter for Flare Gas Applications
Magnetrol TA2 Thermal Mass Flow Meter for Flare Gas Applications
 
Rbef e mini inductive magnetic flow meter-2017-catalog
Rbef e mini  inductive magnetic flow meter-2017-catalogRbef e mini  inductive magnetic flow meter-2017-catalog
Rbef e mini inductive magnetic flow meter-2017-catalog
 
Ultrasonic doppler flowmeter user manual
Ultrasonic doppler flowmeter user manualUltrasonic doppler flowmeter user manual
Ultrasonic doppler flowmeter user manual
 
Omnigrad s taf11, taf12x, taf16 endress+hauser datasheet-high temperature ass...
Omnigrad s taf11, taf12x, taf16 endress+hauser datasheet-high temperature ass...Omnigrad s taf11, taf12x, taf16 endress+hauser datasheet-high temperature ass...
Omnigrad s taf11, taf12x, taf16 endress+hauser datasheet-high temperature ass...
 
Omnigrad m tr44 45 endress+hauser datasheet-hygienic, modular rtd assembly-te...
Omnigrad m tr44 45 endress+hauser datasheet-hygienic, modular rtd assembly-te...Omnigrad m tr44 45 endress+hauser datasheet-hygienic, modular rtd assembly-te...
Omnigrad m tr44 45 endress+hauser datasheet-hygienic, modular rtd assembly-te...
 
Thermal analysis
Thermal analysisThermal analysis
Thermal analysis
 
RBEF-E Mini Inductive Magnetic Flow Meter-2017-catalog
RBEF-E Mini  Inductive Magnetic Flow Meter-2017-catalogRBEF-E Mini  Inductive Magnetic Flow Meter-2017-catalog
RBEF-E Mini Inductive Magnetic Flow Meter-2017-catalog
 
Current To Pneumatic Converter for Process Control
Current To Pneumatic Converter for Process ControlCurrent To Pneumatic Converter for Process Control
Current To Pneumatic Converter for Process Control
 
Ultrasonic flow meter catalog
Ultrasonic flow meter catalogUltrasonic flow meter catalog
Ultrasonic flow meter catalog
 
LS20B Portable Current Meter User Manual
LS20B Portable Current Meter  User ManualLS20B Portable Current Meter  User Manual
LS20B Portable Current Meter User Manual
 
ABB MagMaster - Flow Meter & End to End Testing Procedure
ABB MagMaster - Flow Meter & End to End Testing ProcedureABB MagMaster - Flow Meter & End to End Testing Procedure
ABB MagMaster - Flow Meter & End to End Testing Procedure
 
Titrators
TitratorsTitrators
Titrators
 
Yokogawa Differential Pressure Transmitter
Yokogawa Differential Pressure TransmitterYokogawa Differential Pressure Transmitter
Yokogawa Differential Pressure Transmitter
 
Target flowmeter catalog Z100TF
Target flowmeter catalog Z100TFTarget flowmeter catalog Z100TF
Target flowmeter catalog Z100TF
 
Azbil AX Series Vortex Flow Meters
Azbil AX Series Vortex Flow MetersAzbil AX Series Vortex Flow Meters
Azbil AX Series Vortex Flow Meters
 

Similar to High accuracy ejc hart pressure transmitter bcst

2000 Nissan Sentra Service Repair Manual.pdf
2000 Nissan Sentra Service Repair Manual.pdf2000 Nissan Sentra Service Repair Manual.pdf
2000 Nissan Sentra Service Repair Manual.pdf8ufksjdkdmd
 
2000 Nissan Sentra Service Repair Manual.pdf
2000 Nissan Sentra Service Repair Manual.pdf2000 Nissan Sentra Service Repair Manual.pdf
2000 Nissan Sentra Service Repair Manual.pdff8usejdkdmdm
 
2000 Nissan Sentra Service Repair Manual.pdf
2000 Nissan Sentra Service Repair Manual.pdf2000 Nissan Sentra Service Repair Manual.pdf
2000 Nissan Sentra Service Repair Manual.pdff7isejkddmmd3e
 
2000 Nissan Sentra Service Repair Manual.pdf
2000 Nissan Sentra Service Repair Manual.pdf2000 Nissan Sentra Service Repair Manual.pdf
2000 Nissan Sentra Service Repair Manual.pdffujskekdjdmkm3e
 
2000 nissan sentra service repair manual
2000 nissan sentra service repair manual2000 nissan sentra service repair manual
2000 nissan sentra service repair manualdfjjsjekfkskemme
 
2001 Nissan Pathfinder Service Repair Manual
2001 Nissan Pathfinder Service Repair Manual2001 Nissan Pathfinder Service Repair Manual
2001 Nissan Pathfinder Service Repair Manualfujjfjksekmdm
 
2001 NISSAN SENTRA Service Repair Manual.pdf
2001 NISSAN SENTRA Service Repair Manual.pdf2001 NISSAN SENTRA Service Repair Manual.pdf
2001 NISSAN SENTRA Service Repair Manual.pdfxwm10319888
 
2001 nissan sentra service repair manual
2001 nissan sentra service repair manual2001 nissan sentra service repair manual
2001 nissan sentra service repair manualfjkskekxsdcmdmme
 
Yokogawa EJX110A Differential Pressure Tranismitter
Yokogawa EJX110A Differential Pressure TranismitterYokogawa EJX110A Differential Pressure Tranismitter
Yokogawa EJX110A Differential Pressure TranismitterPower Specialties, Inc.
 
2600T Series Pressure Transmitter Model 261GS Gauge Model 261AS Absolute stan...
2600T Series Pressure Transmitter Model 261GS Gauge Model 261AS Absolute stan...2600T Series Pressure Transmitter Model 261GS Gauge Model 261AS Absolute stan...
2600T Series Pressure Transmitter Model 261GS Gauge Model 261AS Absolute stan...Michael Sun
 
2600T Series Pressure Transmitter Model 261GS Gauge Model 261AS Absolute stan...
2600T Series Pressure Transmitter Model 261GS Gauge Model 261AS Absolute stan...2600T Series Pressure Transmitter Model 261GS Gauge Model 261AS Absolute stan...
2600T Series Pressure Transmitter Model 261GS Gauge Model 261AS Absolute stan...Michael Sun
 
2001 Nissan Maxima Service Repair Manual.pdf
2001 Nissan Maxima Service Repair Manual.pdf2001 Nissan Maxima Service Repair Manual.pdf
2001 Nissan Maxima Service Repair Manual.pdfxwm10319888
 
2001 Nissan Maxima Service Repair Manual.pdf
2001 Nissan Maxima Service Repair Manual.pdf2001 Nissan Maxima Service Repair Manual.pdf
2001 Nissan Maxima Service Repair Manual.pdffujsekddmdmmd
 
2001 Nissan Maxima Service Repair Manual.pdf
2001 Nissan Maxima Service Repair Manual.pdf2001 Nissan Maxima Service Repair Manual.pdf
2001 Nissan Maxima Service Repair Manual.pdffuhsekikdokd
 

Similar to High accuracy ejc hart pressure transmitter bcst (20)

PG Pressure Sensor Brochure
PG Pressure Sensor BrochurePG Pressure Sensor Brochure
PG Pressure Sensor Brochure
 
Thermal mass flow meter Operational Manual.pdf
Thermal mass flow meter Operational Manual.pdfThermal mass flow meter Operational Manual.pdf
Thermal mass flow meter Operational Manual.pdf
 
instruction
instruction instruction
instruction
 
Brooks Ar-Mite Low Flow Armored Flowmeter
Brooks Ar-Mite Low Flow Armored FlowmeterBrooks Ar-Mite Low Flow Armored Flowmeter
Brooks Ar-Mite Low Flow Armored Flowmeter
 
2000 Nissan Sentra Service Repair Manual.pdf
2000 Nissan Sentra Service Repair Manual.pdf2000 Nissan Sentra Service Repair Manual.pdf
2000 Nissan Sentra Service Repair Manual.pdf
 
2000 Nissan Sentra Service Repair Manual.pdf
2000 Nissan Sentra Service Repair Manual.pdf2000 Nissan Sentra Service Repair Manual.pdf
2000 Nissan Sentra Service Repair Manual.pdf
 
2000 Nissan Sentra Service Repair Manual.pdf
2000 Nissan Sentra Service Repair Manual.pdf2000 Nissan Sentra Service Repair Manual.pdf
2000 Nissan Sentra Service Repair Manual.pdf
 
2000 Nissan Sentra Service Repair Manual.pdf
2000 Nissan Sentra Service Repair Manual.pdf2000 Nissan Sentra Service Repair Manual.pdf
2000 Nissan Sentra Service Repair Manual.pdf
 
2000 nissan sentra service repair manual
2000 nissan sentra service repair manual2000 nissan sentra service repair manual
2000 nissan sentra service repair manual
 
Target flowmeter catalog.zero100tf
Target flowmeter catalog.zero100tfTarget flowmeter catalog.zero100tf
Target flowmeter catalog.zero100tf
 
2001 Nissan Pathfinder Service Repair Manual
2001 Nissan Pathfinder Service Repair Manual2001 Nissan Pathfinder Service Repair Manual
2001 Nissan Pathfinder Service Repair Manual
 
2001 NISSAN SENTRA Service Repair Manual.pdf
2001 NISSAN SENTRA Service Repair Manual.pdf2001 NISSAN SENTRA Service Repair Manual.pdf
2001 NISSAN SENTRA Service Repair Manual.pdf
 
2001 nissan sentra service repair manual
2001 nissan sentra service repair manual2001 nissan sentra service repair manual
2001 nissan sentra service repair manual
 
Yokogawa EJX110A Differential Pressure Tranismitter
Yokogawa EJX110A Differential Pressure TranismitterYokogawa EJX110A Differential Pressure Tranismitter
Yokogawa EJX110A Differential Pressure Tranismitter
 
2600T Series Pressure Transmitter Model 261GS Gauge Model 261AS Absolute stan...
2600T Series Pressure Transmitter Model 261GS Gauge Model 261AS Absolute stan...2600T Series Pressure Transmitter Model 261GS Gauge Model 261AS Absolute stan...
2600T Series Pressure Transmitter Model 261GS Gauge Model 261AS Absolute stan...
 
2600T Series Pressure Transmitter Model 261GS Gauge Model 261AS Absolute stan...
2600T Series Pressure Transmitter Model 261GS Gauge Model 261AS Absolute stan...2600T Series Pressure Transmitter Model 261GS Gauge Model 261AS Absolute stan...
2600T Series Pressure Transmitter Model 261GS Gauge Model 261AS Absolute stan...
 
Submersible Hydrostatic Level Indicators
Submersible Hydrostatic Level IndicatorsSubmersible Hydrostatic Level Indicators
Submersible Hydrostatic Level Indicators
 
2001 Nissan Maxima Service Repair Manual.pdf
2001 Nissan Maxima Service Repair Manual.pdf2001 Nissan Maxima Service Repair Manual.pdf
2001 Nissan Maxima Service Repair Manual.pdf
 
2001 Nissan Maxima Service Repair Manual.pdf
2001 Nissan Maxima Service Repair Manual.pdf2001 Nissan Maxima Service Repair Manual.pdf
2001 Nissan Maxima Service Repair Manual.pdf
 
2001 Nissan Maxima Service Repair Manual.pdf
2001 Nissan Maxima Service Repair Manual.pdf2001 Nissan Maxima Service Repair Manual.pdf
2001 Nissan Maxima Service Repair Manual.pdf
 

More from Emily Xu

Globe control valve catalog
Globe control valve catalogGlobe control valve catalog
Globe control valve catalogEmily Xu
 
Pneumatic on off valve
Pneumatic on off valvePneumatic on off valve
Pneumatic on off valveEmily Xu
 
Control valve by BCST
Control valve by BCSTControl valve by BCST
Control valve by BCSTEmily Xu
 
Jc080 smart vortex flowmeter-bcst
Jc080 smart vortex flowmeter-bcstJc080 smart vortex flowmeter-bcst
Jc080 smart vortex flowmeter-bcstEmily Xu
 
Electromagnetic flow meter bcst
Electromagnetic flow meter bcstElectromagnetic flow meter bcst
Electromagnetic flow meter bcstEmily Xu
 
Bcst flow measurement solution(complete)
Bcst flow measurement solution(complete)Bcst flow measurement solution(complete)
Bcst flow measurement solution(complete)Emily Xu
 
Flow measurement solution general catalog
Flow measurement solution general catalogFlow measurement solution general catalog
Flow measurement solution general catalogEmily Xu
 
Bcst flow measurement solution(complete)
Bcst flow measurement solution(complete)Bcst flow measurement solution(complete)
Bcst flow measurement solution(complete)Emily Xu
 
Magnetic float level guage by BCST
 Magnetic float level guage by BCST  Magnetic float level guage by BCST
Magnetic float level guage by BCST Emily Xu
 
Flow measurement solution by BCST
Flow measurement solution by BCST Flow measurement solution by BCST
Flow measurement solution by BCST Emily Xu
 
Newest catalog for Jiangsu Jiechuang Science And Technology Co.,Ltd
Newest catalog for Jiangsu Jiechuang Science And Technology Co.,Ltd Newest catalog for Jiangsu Jiechuang Science And Technology Co.,Ltd
Newest catalog for Jiangsu Jiechuang Science And Technology Co.,Ltd Emily Xu
 
BCST Group Catalog
BCST Group Catalog BCST Group Catalog
BCST Group Catalog Emily Xu
 

More from Emily Xu (12)

Globe control valve catalog
Globe control valve catalogGlobe control valve catalog
Globe control valve catalog
 
Pneumatic on off valve
Pneumatic on off valvePneumatic on off valve
Pneumatic on off valve
 
Control valve by BCST
Control valve by BCSTControl valve by BCST
Control valve by BCST
 
Jc080 smart vortex flowmeter-bcst
Jc080 smart vortex flowmeter-bcstJc080 smart vortex flowmeter-bcst
Jc080 smart vortex flowmeter-bcst
 
Electromagnetic flow meter bcst
Electromagnetic flow meter bcstElectromagnetic flow meter bcst
Electromagnetic flow meter bcst
 
Bcst flow measurement solution(complete)
Bcst flow measurement solution(complete)Bcst flow measurement solution(complete)
Bcst flow measurement solution(complete)
 
Flow measurement solution general catalog
Flow measurement solution general catalogFlow measurement solution general catalog
Flow measurement solution general catalog
 
Bcst flow measurement solution(complete)
Bcst flow measurement solution(complete)Bcst flow measurement solution(complete)
Bcst flow measurement solution(complete)
 
Magnetic float level guage by BCST
 Magnetic float level guage by BCST  Magnetic float level guage by BCST
Magnetic float level guage by BCST
 
Flow measurement solution by BCST
Flow measurement solution by BCST Flow measurement solution by BCST
Flow measurement solution by BCST
 
Newest catalog for Jiangsu Jiechuang Science And Technology Co.,Ltd
Newest catalog for Jiangsu Jiechuang Science And Technology Co.,Ltd Newest catalog for Jiangsu Jiechuang Science And Technology Co.,Ltd
Newest catalog for Jiangsu Jiechuang Science And Technology Co.,Ltd
 
BCST Group Catalog
BCST Group Catalog BCST Group Catalog
BCST Group Catalog
 

Recently uploaded

Double rodded leveling 1 pdf activity 01
Double rodded leveling 1 pdf activity 01Double rodded leveling 1 pdf activity 01
Double rodded leveling 1 pdf activity 01KreezheaRecto
 
result management system report for college project
result management system report for college projectresult management system report for college project
result management system report for college projectTonystark477637
 
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Dr.Costas Sachpazis
 
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...ranjana rawat
 
University management System project report..pdf
University management System project report..pdfUniversity management System project report..pdf
University management System project report..pdfKamal Acharya
 
PVC VS. FIBERGLASS (FRP) GRAVITY SEWER - UNI BELL
PVC VS. FIBERGLASS (FRP) GRAVITY SEWER - UNI BELLPVC VS. FIBERGLASS (FRP) GRAVITY SEWER - UNI BELL
PVC VS. FIBERGLASS (FRP) GRAVITY SEWER - UNI BELLManishPatel169454
 
Thermal Engineering Unit - I & II . ppt
Thermal Engineering  Unit - I & II . pptThermal Engineering  Unit - I & II . ppt
Thermal Engineering Unit - I & II . pptDineshKumar4165
 
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Bookingroncy bisnoi
 
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...Call Girls in Nagpur High Profile
 
Intze Overhead Water Tank Design by Working Stress - IS Method.pdf
Intze Overhead Water Tank  Design by Working Stress - IS Method.pdfIntze Overhead Water Tank  Design by Working Stress - IS Method.pdf
Intze Overhead Water Tank Design by Working Stress - IS Method.pdfSuman Jyoti
 
chapter 5.pptx: drainage and irrigation engineering
chapter 5.pptx: drainage and irrigation engineeringchapter 5.pptx: drainage and irrigation engineering
chapter 5.pptx: drainage and irrigation engineeringmulugeta48
 
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...roncy bisnoi
 
Thermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VThermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VDineshKumar4165
 
Call for Papers - International Journal of Intelligent Systems and Applicatio...
Call for Papers - International Journal of Intelligent Systems and Applicatio...Call for Papers - International Journal of Intelligent Systems and Applicatio...
Call for Papers - International Journal of Intelligent Systems and Applicatio...Christo Ananth
 
UNIT-IFLUID PROPERTIES & FLOW CHARACTERISTICS
UNIT-IFLUID PROPERTIES & FLOW CHARACTERISTICSUNIT-IFLUID PROPERTIES & FLOW CHARACTERISTICS
UNIT-IFLUID PROPERTIES & FLOW CHARACTERISTICSrknatarajan
 
UNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular ConduitsUNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular Conduitsrknatarajan
 

Recently uploaded (20)

Double rodded leveling 1 pdf activity 01
Double rodded leveling 1 pdf activity 01Double rodded leveling 1 pdf activity 01
Double rodded leveling 1 pdf activity 01
 
(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7
(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7
(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7
 
result management system report for college project
result management system report for college projectresult management system report for college project
result management system report for college project
 
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
 
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
 
University management System project report..pdf
University management System project report..pdfUniversity management System project report..pdf
University management System project report..pdf
 
PVC VS. FIBERGLASS (FRP) GRAVITY SEWER - UNI BELL
PVC VS. FIBERGLASS (FRP) GRAVITY SEWER - UNI BELLPVC VS. FIBERGLASS (FRP) GRAVITY SEWER - UNI BELL
PVC VS. FIBERGLASS (FRP) GRAVITY SEWER - UNI BELL
 
Thermal Engineering Unit - I & II . ppt
Thermal Engineering  Unit - I & II . pptThermal Engineering  Unit - I & II . ppt
Thermal Engineering Unit - I & II . ppt
 
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
 
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
 
Intze Overhead Water Tank Design by Working Stress - IS Method.pdf
Intze Overhead Water Tank  Design by Working Stress - IS Method.pdfIntze Overhead Water Tank  Design by Working Stress - IS Method.pdf
Intze Overhead Water Tank Design by Working Stress - IS Method.pdf
 
NFPA 5000 2024 standard .
NFPA 5000 2024 standard                                  .NFPA 5000 2024 standard                                  .
NFPA 5000 2024 standard .
 
chapter 5.pptx: drainage and irrigation engineering
chapter 5.pptx: drainage and irrigation engineeringchapter 5.pptx: drainage and irrigation engineering
chapter 5.pptx: drainage and irrigation engineering
 
Call Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
Call Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort ServiceCall Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
Call Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
 
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
 
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
 
Thermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VThermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - V
 
Call for Papers - International Journal of Intelligent Systems and Applicatio...
Call for Papers - International Journal of Intelligent Systems and Applicatio...Call for Papers - International Journal of Intelligent Systems and Applicatio...
Call for Papers - International Journal of Intelligent Systems and Applicatio...
 
UNIT-IFLUID PROPERTIES & FLOW CHARACTERISTICS
UNIT-IFLUID PROPERTIES & FLOW CHARACTERISTICSUNIT-IFLUID PROPERTIES & FLOW CHARACTERISTICS
UNIT-IFLUID PROPERTIES & FLOW CHARACTERISTICS
 
UNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular ConduitsUNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular Conduits
 

High accuracy ejc hart pressure transmitter bcst

  • 1. Jiangsu BCST GROUP CO.,Ltd JIANGSU BCST GROUP CO.,LTD Add:288#,Tongtai road,Jinhu Industrial Park ,Huai'an Jiangsu,China, 211600 Tel:0086-517-86989565 Fax:0086-517-86980638 Email:info@bcstgroup.com Web: www.bcstgroup.net Differential / Pressure Transmitter / Gauge/Absolute Pressure Transmitter Differential Pressure Level Transmitter Remote Seal Differential Pressure Transmitter Remote Seal Gauge/Absolute Pressure Transmitter Silicon Sensor Type Transmitter Catalogue
  • 2. EJC Smart Pressure Transmitter Product Overview www.bcstgroup.com A1 BCST Group C.,Ltd Contents 1 Technical Background…………………………………………………………………………A2 2 Principle of Operation…………………………………………………………………………A3 3 Main Specification………………………………………………………………………………A3 4 Product Overview………………………………………………………………………………A4 5 EJCDP-A High Performance Differential Pressure Transmitter ………………………1 6 EJCBP-A High Performance Gauge/Absolute Pressure Transmitter ………………7 7 EJCDP-B/C Differential Pressure Transmitter……………………………………………14 8 EJCBP/A-B/C Gauge/Absolute Pressure Transmitter……………………………………21 9 EJCDM Micro-Differential Pressure Transmitter …………………………………………27 10 EJCLT Differential Pressure Level Transmitter …………………………………………33 11 EJCRHL Remote Seal Differential Pressure Transmitter………………………………39 12 EJCRNS Remote Seal Gauge/Absolute Pressure Transmitter ……………………48 13 EJCBP/A-S Sanitary Gauge/Absolute Pressure Transmitter …………………64 14 EJCBP/A-S Sanitary Gauge/Absolute Pressure Transmitter ……………………73 15 EJCDP-S Sanitary Remote Seal Differential Pressure Transmitter …………………80 16 EJCMT Multi Variable Pressure Transmitter………………………………………………87
  • 3. EJC Smart Pressure Transmitter Product Overview www.bcstgroup.com A2 BCST Group C.,Ltd Technical background BCST Group Co.,Ltd, with solid and strong technical background, has close cooperation with several famous research institutes and groups in Europe (such as EPFL, IMT of University of Neuchatel, CESM).The research achievements transfer rate is over 93%. It also retains good cooperation relationship with several world leading sensor, instruments & meters, automation equipment, micro-electronics and micromechanics corporations in Europe. Jiangsu BCST Group Co.,Ltd is granted by BCST Group Co.,Ltd the complete authorization for its world leading core sensing technology and production-manufacturing techniques of pressure instruments & meters. BCST supply one step solution for pressure transmitter
  • 4. EJC Smart Pressure Transmitter Product Overview www.bcstgroup.com A3 BCST Group C.,Ltd Principle of Operation EJCDP Differential Pressure Transmitter The differential pressure transmitter includes two functional units: —Main unit —Auxiliary Unit The main unit includes a sensor and process connection. The completely welded sensor module is a twin-chamber system with an integral overload diaphragm, an absolute pressure sensor, a temperature sensor and the silicon differential pressure sensor. The absolute pressure sensor, which is only exposed to the pressure at the high pressure side, acts as a reference value to compensate for the static pressure. The temperature sensor as a temperature compensated reference value to compensate for the temperature drift. RP1002/3 Gauge/Absolute Pressure Transmitter The gauge/absolute pressure transmitter includes two functional units: —Main unit —Auxiliary Unit The main unit includes gauge/absolute/temperature sensors and process connection. The low pressure span completely welded sensor module is a twin-chamber system with an integral overload diaphragm, and a silicon pressure sensor. The temperature sensor as a temperature compensated reference value to compensate for the temperature drift. Main Specification  The differential pressure transmitter utilize the world's leading high stability silicon sensor, the highest Reference Accuracy is ±0.05%;  Micro-differential pressure transmitter utilize the world's leading dual overload diaphragm patented technology, the highest Reference Accuracy is ±0.075%;  The differential pressure transmitter working pressure are 16 MPa, 25 MPa and 40MPa, the one-way overload pressure up to 40MPa;  The absolute pressure sensor packaged in the differential pressure transmitter, can be used for static pressure measurement, display , and the static pressure compensation. The minimum of the static error is ≤±0.05 %/10MPa;  High sensitivity temperature sensor packaged in the sensor. The minimum of the temperature error is ≤±0.04 %/10K;  Stainless steel 316L and silicone oil filling welded seal structure;  Micro-pressure / absolute pressure transmitter utilize the no pressure transmission loss overload diaphragm patented technology , the one-way overload pressure up to 7MPa;  Long stability is ≤±0.1%/3years, 10 years of maintenance-free;  Extremely wide measuring range 100Pa~60MPa;  Adjustable up to 100:1 range ability;  The remote seal transmitter utilize ultra-high temperature(400℃) patented technology.
  • 5. EJC Smart Pressure Transmitter Product Overview www.bcstgroup.com A4 BCST Group C.,Ltd Product Overview 1 EJCDP-A/B/C/D Differential Pressure Transmitter  Measurement medium: gas, steam, liquid  Range Limits: 0—100Pa~3MPa  Accuracy:±0.05%、±0.075%、±0.1%、±0.25%  Isolating Diaphragm:316L / Hastelloy C / Gold plated on 316L / FEP plated on 316L / Tantalum 2 EJCBP-A/B/C Gauge Pressure Transmitter EJCBA-A/B/C Absolute Pressure Transmitter  Measurement medium: gas, steam, liquid  Range Limits: 0—600Pa~40MPa  Accuracy:±0.05%、±0.075%、±0.1%、±0.25%  Isolating Diaphragm:316L / Hastelloy C 3 EJCLT Differential Pressure Level Transmitter  Suitable for measuring the fluid medium of high temperature, high viscosity, corrosive, easy to precipitate  Range Limits:0—1kPa~3MPa  Fill fluid: silicone oil, vegetable oil  Isolating Diaphragm:316L / Hastelloy C / Gold plated on 316L / FEP or PFA plated on 316L / Tantalum 4 EJC Differential Pressure Remote Seal Transmitter  Suitable for measuring the fluid medium of the high temperature 400 ℃,high viscosity, corrosive, easy to precipitation  Range Limits:0—1kPa~3MPa  Fill fluid: silicone oil, high temperature silicone oil, ultra-high-temperature silicone oil, vegetable oil  Isolating Diaphragm:316L / Hastelloy C / Gold plated on 316L / FEP or PFA plated on 316L / Tantalum
  • 6. EJC Smart Pressure Transmitter Product Overview www.bcstgroup.com A5 BCST Group C.,Ltd 5 EJCRN Gauge Pressure Remote Seal Transmitter EJCRS Absolute Pressure Remote Seal Transmitter  Suitable for measuring the fluid medium of the high temperature 400 ℃,high viscosity, corrosive, easy to precipitation  Range Limits: 0—1kPa~40MPa  Fill fluid: silicone oil, high temperature silicone oil, ultra-high-temperature silicone oil, vegetable oil  Isolating Diaphragm:316L / Hastelloy C / Gold plated on 316L / FEP or PFA plated on 316L / Tantalum 6 EJCBP-S Sanitary Gauge Pressure Transmitter EJCBA-S Sanitary Absolute Pressure Transmitter  Measurement medium: gas, steam, liquid  Range Limits: 0—2kPa~3MPa  Isolating Diaphragm:316L  Fill fluid: silicone oil, vegetable oil 7 EJCDP-S Sanitary Differential Pressure Remote Seal Transmitter  Measurement medium: gas, steam, liquid  Range Limits: 0—2kPa~250kPa  Isolating Diaphragm:316L  Fill fluid: silicone oil, vegetable oil 8 JCMT- Multi Variable Pressure Transmitter  Measurement medium: gas, steam, liquid  Range Limits: 0—2kPa~2MPA  Isolating Diaphragm:316L / Hastelloy C / Gold plated on 316L / FEP or PFA plated on 316L / Tantalum  Fill fluid: silicone oil, vegetable oil
  • 7. EJC serial High Performance Differential Pressure Transmitter General Specifications www.bcstgroup.com 1 info@bcstgroup.com EJCDP-A High Performance Differential Pressure Transmitter The high performance differential pressure transmitter EJCDP-A is suitable to measure liquid, gas, or steam flow as well as liquid level, density and pressure. EJCDP-A outputs a 4~20 mADC signal corresponding to the measured differential pressure. Its highly accurate and stable sensor can also measure the static pressure which can be shown on the integral indicator or remotely monitored via HART communications. Other key features include quick response, remote set-up using communications, self-diagnostics and optional status output for pressure high/low alarm. STANDARD SPECIFICATIONS 1 PERFORMANCE SPECIFICATIONS Reference Accuracy of Calibrated Span (includes terminal-based linearity, hysteresis, and repeatability) ± 0.05% If TD>10(TD=URL/SPAN),±(0.005×TD)% The square root accuracy is 1.5 times of reference accuracy of calibrated span. Ambient Temperature Effects -20℃~65℃:±(0.075×TD+0.025)%×Span Every 10℃ is ±0.04% ×Span (TD=1) -40℃~-20℃ & 65℃~85℃: ±(0.1×TD+0.025)%×Span Static Pressure Effects ±(0.025%URL+0.05%Span)/10MPa Overpressure Effects: ±0.05%×Span /10MPa Stability:±0.1%×Span /3 years Power Supply Effects: ±0.001% /10V (12~42V DC) 2 FUNCTIONAL SPECIFICATIONS Span and Range Limits Span/ Range Limits kPa inH2O mbar mmH2O C Span 0.4~ 40 1.6~ 160 4~400 40~4000 Range Limits -40~ 40 -160~ 160 -400~ 400 -4000~ 4000 D Span 2.5~ 250 10~ 1000 25~ 2500 0.25~ 25mH2O Range Limits -250 ~250 -1000 ~1000 -2500 ~2500 -25~ 25mH2O F Span 30~ 3000 120~ 12000 0.3~ 30 bar 3~ 300mH2O Range Limits -500 ~ 3000 -2000 ~ 12000 -5~ 30bar -5~ 300mH2O Zero Adjustment Limits Zero can be fully elevated or suppressed, within the lower and upper range limits of the capsule. External Zero Adjustment External zero is continuously adjustable with 0.01% incremental resolution of span. Re-range can be done locally using the range setting switch. Mounting Position Effects
  • 8. EJC serial High Performance Differential Pressure Transmitter General Specifications www.bcstgroup.com 2 info@bcstgroup.com Rotation in diaphragm plane has no effect. Tilting up to 90° will cause zero shift up to 0.4 kPa (40 mmH2O) which can be corrected by the zero adjustment. Output Two wire 4~20 mADC output with digital communications, linear or square root programmable. HART FSK protocol are superimposed on the 4~20 mADC signal. Output range: 3.9 mA to 20.5 mA. Failure Alarm (the mode can be selected) Low Mode (min): 3.7 mA High Mode (max): 21 mA No Mode (hold): Keep the effective value before the fault. Note: The standard setting of failure alarm is High Mode. Response Time The amplifier damping constant is 0.1 sec; The sensor damping constant is 0.1~1.6 sec, it depends on the range and range compression ratio. Amplifier damping time constant is adjustable from 0.1 to 60 sec by software and added to response time. UpTime < 15s Ambient Temperature Limits -40 to 85°C -20 to 65°C with LCD display or fluorine rubber sealing Storage and Transportation Temperature Limits -50 to 85°C -40 to 85°C with LCD display Working Pressure Limits (Silicone oil) Maximum working pressure:16MPa,25MPa,40MPa Static Pressure Limits 3.5kPa abs. to maximum working pressure. One-way Overload Pressure Limit The maximum one-way overload pressure is maximum working pressure. Electromagnetic Compatibility (EMC) Look the EMC Performance Table Explosion Protected Type NEPSI / ATXE: Ex dⅡC T6 NEPSI / ATXE: Ex iaⅡC T4 Amb. Temp.: -40℃~65℃ 3 INSTALL Supply & Load Requirements 24VDC supply, R ≤ (Us-12V)/Imax kΩ, Imax=23 mA. Maximum voltage limited: 42VDC, Minimum voltage limited: 12VDC, 15VDC(with LCD display) 230Ω to 600Ω for digital communication Electrical Connection The electrical connection is made via cable entry M20x1.5.The screw terminals are suitable for wire cross-sections up to 2.5mm2 . Process Connection Flange with fixing thread 7/16-20 UNF and 1/4-18 NPT female thread on both sides. 4 PHYSICAL SPECIFICATIONS Wetted Parts Materials Sensor Body: 316L stainless steel Isolating Diaphragm:316L stainless steel / Hastelloy C/Gold plated on 316L/FEP plated on 316L/Tantalum Cover Flange: 316 stainless steel Nuts and Bolts: 304 stainless steel Process Connector: 316 stainless steel Fill fluid: Silicone oil/Fluorinated oil Process Connector Gasket:Perbunan(NBR)/Viton (FKM)/Teflon(PTFE) Amplifier Housing: Aluminum with epoxy resin coat Housing Gasket: Perbunan(NBR) Name plate and tag:304 stainless steel Weight: 3.3kg Degrees of Protection: IP67
  • 9. EJC serial High Performance Differential Pressure Transmitter General Specifications www.bcstgroup.com 3 info@bcstgroup.com EMC Performance Table Items Test items Basic standards Test conditions Performance Level 1 Radiated interference (Housing) GB/T 9254-2008 30MHz~1000MHz OK 2 Conducted interference(DC power port) GB/T 9254-2008 0.15MHz~30MHz OK 3 Electrostatic Discharge (ESD) Immunity GB/T 17626.2-2006 4kV(Line) 8kV(Air) B 4 RF electromagnetic field immunity GB/T 17626.3-2006 10V/m (80MHz~1GHz) A 5 Frequency magnetic field immunity GB/T 17626.8-2006 30A/m A 6 Electrical Fast Transient Burst Immunity GB/T 17626.4-2008 2kV(5/50ns,5kHz) B 7 Surge Immunity GB/T 17626.5-2008 0.5kV(line to line) 1kV(line to ground) (1.2us/50us) B 8 Conducted interference immunity induced by RF field GB/T 17626.6-2008 3V (150KHz~80MHz) A Note:(1)Performance level A description: The technical specifications within the limits of normal performance. (2)Performance level B description: Temporary reduction or loss of functionality or performance, it can restore itself. The actual operating conditions, storage, and data will not be changed. DIMENSIONS Unit : mm Horizontal Impulse Piping Type(side face) Horizontal Impulse Piping Type(front side)
  • 10. EJC serial High Performance Differential Pressure Transmitter General Specifications www.bcstgroup.com 4 info@bcstgroup.com Horizontal Impulse Wall mounting Type Vertical Impulse Piping Type 5 Terminal Configuration 6 Vertical mounting flange (Code V) Note:Quick interface functionally equivalent to the signal terminal 7 Process connections Description
  • 11. EJC serial High Performance Differential Pressure Transmitter General Specifications www.bcstgroup.com 5 info@bcstgroup.com 8 Model and suffix codes High Performance Differential Pressure Transmitter EJCDP- 10 Accuracy A Reference Accuracy±0.05% 20 Span C 0-400Pa~40kPa(0-40~4000 mmH2O)/(0-4~400mbar) D 0-2.5kPa~250kPa(0-0.25~25 mH2O)/(0-25~2500mbar) F 0-30kPa~3MPa(0-3~300 mH2O)/(0-0.3~30bar) 30 Static pressure sensor 0 None 1 40MPa 2 10MPa 40 Diaphragm fill fluid A 316L stainless steel Silicone oil B 316L stainless steel Fluorinated oil C Hastelloy C Silicone oil D Hastelloy C Fluorinated oil E Gold plated on 316L Silicone oil F Gold plated on 316L Fluorinated oil G FEP plated on 316L Silicone oil T Tantalum Silicone oil 50 Working pressure 1 16MPa 2 25MPa 3 40MPa 60 Process connections N 7/16-20 UNF and 1/4-18 NPT female thread, No relief valve B 7/16-20 UNF and 1/4-18 NPT female thread, Relief valves at end of flanges U 7/16-20 UNF and 1/4-18 NPT female thread, Relief valves at the upper part of the flange side D 7/16-20 UNF and 1/4-18 NPT female thread, Relief valve at the lower part of the flange side V Vertical mounting flange, 7/16-20 UNF and 1/4-18 NPT female thread, Relief valves at the upper part of the flange side L Level(Low side can select : B/ U/ D) R Remote Seal 70 Process connector gasket N Perbunan(NBR) F Viton (FKM) P Teflon (PTFE) 80 Special function N None F Square root output O Degrease cleansing treatment(Oxygen measurement must be with
  • 12. EJC serial High Performance Differential Pressure Transmitter General Specifications www.bcstgroup.com 6 info@bcstgroup.com fluorinated oil filled capsule, Viton (FKM) gasket, <6MPa ,<60℃) P Anti-lightning function 90 Mounting bracket N None 1 304 stainless steel 2 Carbon steel galvanized 100 Process connector accessory N None 1 Stainless steel oval-shaped flange with 1/2 NPT female thread 2 Stainless steel D-shaped connector with M20x1.5 male thread 110 Integral indicator N None 1 LCD display 2 Backlit LCD display 120 Explosion protected type N None A Intrinsically safe Approval for NEPSI D Flameproof Approval for NEPSI B Intrinsically safe Approval for ATEX E Gas Flameproof Approval for ATEX G Dust Flameproof Approval for ATEX H Gas & Dust Flameproof Approval for ATEX 130 Tag name plate N None 1 Position number marked on the nameplate 2 Hanging stainless steel plate 140 Housing mateiral A Aluminium alloy S 316 SS Order example:EJCDP-AC2A1BNF111N1C [A]:Reference Accuracy:±0.05% [1]:With 304 stainless steel mounting bracket [C]:Span:0-400Pa~40kPa(0-40~4000 mmH2O) [1]:With stainless steel oval-shaped flange [2]:Static pressure sensor:10MPa with 1/2 NPT female thread [A]:316L stainless steel diaphragm, Silicone oil fill fluid [1]:With LCD display [1]:Working pressure:16MPa [N]:None of explosion protected type [B]:7/16-20 UNF and 1/4-18 NPT female thread, [1]:Position number marked on the nameplate Relief valves at end of flanges [A]:Aluminium alloy [N]:Perbunan(NBR)process connector gasket [F]:Square root output
  • 13. EJCB- High Performance Pressure Transmitter General Specification www.bcstgroup.com 7 info@bcstgroup.com EJCB-P High Performance Gauge Pressure Transmitter EJC-A High Performance Absolute Pressure Transmitter The high performance pressure transmitter EJCBP is suitable to measure liquid, gas, or steam flow as well as liquid level, density and pressure. EJCBP/A outputs a 4~20mADC signal corresponding to the measured pressure. The key features include quick response, remote set-up using communications, self-diagnostics and optional status output for pressure high/low alarm. STANDARD SPECIFICATIONS 1 PERFORMANCE SPECIFICATIONS Reference Accuracy of Calibrated Span (includes terminal-based linearity, hysteresis, and repeatability) ± 0.05% If TD>10(TD=URL/SPAN),±(0.005×TD)% Ambient Temperature Effects -20℃~65℃:±(0.075×TD+0.025)%×Span Every 10℃ is ±0.04% ×Span (TD=1) -40℃~-20℃ & 65℃~85℃: ±(0.1×TD+0.025)%×Span Overpressure Effects: ±0.05%×Span Stability:±0.1%×Span /3 years Power Supply Effects: ±0.001% /10V (12~42V DC) 2 FUNCTIONAL SPECIFICATIONS Zero Adjustment Limits Zero can be fully elevated or suppressed, within the lower and upper range limits of the capsule. Span and Range Limits(RP1002-A) Span/ Range Limits kPa psi bar Kgf/cm 2 C/ S Span 2~40 0.29~ 5.8 0.02 ~0.4 0.02 ~0.4 Range Limits -40~40 -5.8~ 5.8 -0.4~ 0.4 -0.4~ 0.4 D Span 2.5~ 250 0.3625 ~36.25 0.025 ~2.5 0.025 ~2.5 Range Limits -100~ 250 -14.5~ 36.25 -1~ 2.5 -1~ 2.5 F Span 30~ 3000 4.35~ 435 0.3~ 30 0.3~ 30 Range Limits -100~ 3000 -14.5~ 435 -1~ 30 -1~ 30 G Span 0.1~ 10MPa 14.5~ 1450 1~ 100 1~ 100 Range Limits -0.1~ 10MPa -14.5~ 1450 -1~ 100 -1~ 100 H Span 0.21~ 21 MPa 30.45~ 3045 2.1~ 210 2.1~ 210 Range Limits -0.1~21 MPa -14.5~ 8000 -1~ 210 -1~ 210 I Span 0.4~40 MPa 58~ 5800 4~ 400 4~ 400 Range Limits -0.1~40 MPa -14.5~ 5800 -1~ 400 -1~ 400 Span and Range(RP1003-A) Span/ Range Limits kPa psi bar Kgf/cm2 M Span 2.5~ 250 0.3625 ~36.25 0.025 ~2.5 0.025 ~2.5 Range Limits 0~ 250 0~ 36.25 0~2.5 0~2.5 O Span 30~ -4.35~ 0.3~ 0.3~
  • 14. EJCB- High Performance Pressure Transmitter General Specification www.bcstgroup.com 8 info@bcstgroup.com 3000 435 30 30 Range Limits 0~ 3000 0~435 0~30 0~30 External Zero Adjustment External zero is continuously adjustable with 0.01% incremental resolution of span. Re-range can be done locally using the range setting switch. Mounting Position Effects Rotation in diaphragm plane has no effect. Tilting up to 90° will cause zero shift up to 0.25kPa which can be corrected by the zero adjustment. Output Two wire 4~20mADC output with digital communications, linear or square root programmable. HART FSK protocol are superimposed on the 4~20 mADC signal. Output range: 3.9 mA to 20.5 mA Failure Alarm (the mode can be selected) Low Mode (min): 3.7 mA, High Mode (max): 21 mA No Mode (hold): Keep the effective value before fault. The standard setting of failure alarm is High Mode. Response Time The amplifier damping constant is 0.1 sec; The sensor damping constant is 0.1~1.6 sec, it depends on the range and range compression ratio. Amplifier damping time constant is adjustable from 0.1 to 60 sec by software and added to response time. UpTime < 15s Ambient Temperature Limits: -40 to 85°C -20 to 65°C with LCD display or fluorine rubber sealing Storage and Transportation Temperature Limits -50 to 85°C, -40 to 85°C with LCD display Working Pressure Limits (Silicone oil) From vacuum to upper range limits Overload Pressure Limits Span 40kPa 250kPa 3MPa (D/M) (F/O) (C) (S) OPL 1MPa 7MPa 4MPa 15MPa Span 10MPa(G) 21MPa(H) 40MPa(I) OPL 20MPa 50MPa 50MPa Electromagnetic Compatibility (EMC) Look the EMC Performance Table Explosion Protected Type NEPSI / ATEX: Ex dⅡC T6, NEPSI / ATEX: Ex iaⅡC T4 Amb. Temp.: -40℃~65℃ 3 INSTALL Supply & Load Requirements 24VDC supply, R≤(Us-12V)/Imax kΩ, Imax=23 mA. Maximum voltage limited: 42VDC, Minimum voltage limited: 12VDC, 15VDC(with LCD display) 230Ω to 600Ω for digital communication Electrical Connection The electrical connection is made via cable entry M20x1.5.The screw terminals are suitable for wire cross-sections up to 2.5mm2 . Process Connection Default Process Connection:1/2-NPT female thread, it can be changed to 1/2-NPT,G1/2,M20x1.5male thread and KF16 vacuum Connection. 4 PHYSICAL SPECIFICATIONS Isolating Diaphragm: 316L stainless steel/Hastelloy C Process Connector: 316 stainless steel Fill fluid: Silicone oil/Fluorinated oil Amplifier Housing: Aluminum with epoxy resin coat Housing Gasket: Perbunan(NBR) Name plate and tag:304 stainless steel Weight: 1.6kg Degrees of Protection: IP67
  • 15. EJCB- High Performance Pressure Transmitter General Specification www.bcstgroup.com 9 info@bcstgroup.com EMC Performance Table Items Test items Basic standards Test conditions Performance Level 1 Radiated interference (Housing) GB/T 9254-2008 30MHz~1000MHz OK 2 Conducted interference(DC power port) GB/T 9254-2008 0.15MHz~30MHz OK 3 Electrostatic Discharge (ESD) Immunity GB/T 17626.2-2006 4kV(Line) 8kV(Air) B 4 RF electromagnetic field immunity GB/T 17626.3-2006 10V/m (80MHz~1GHz) A 5 Frequency magnetic field immunity GB/T 17626.8-2006 30A/m A 6 Electrical Fast Transient Burst Immunity GB/T 17626.4-2008 2kV(5/50ns,5kHz) B 7 Surge Immunity GB/T 17626.5-2008 0.5kV(line to line) 1kV(line to ground) (1.2us/50us) B 8 Conducted interference immunity induced by RF field GB/T 17626.6-2008 3V (150KHz~80MHz) A Note:(1)Performance level A description: The technical specifications within the limits of normal performance. (2)Performance level B description: Temporary reduction or loss of functionality or performance, it can restore itself. The actual operating conditions, storage, and data will not be changed. DIMENSIONS Unit : mm Horizontal Impulse Piping Type(side face) Horizontal Impulse Piping Type(front side)
  • 16. EJCB- High Performance Pressure Transmitter General Specification www.bcstgroup.com 10 info@bcstgroup.com Horizontal Impulse Wall mounting Type Vertical Impulse Piping Type 5 Terminal Configuration Note:Quick interface functionally equivalent to the signal terminal 6 Process connections Description 6.1 Default Process Connection(Code 1) F/G/H/I/O Span C/S/D/M Span
  • 17. EJCB- High Performance Pressure Transmitter General Specification www.bcstgroup.com 11 info@bcstgroup.com 6.2 Other forms of Process connector 1/2-NPT male thread(Code 2) M20x1.5 male thread(Code3) G 1/2 male thread(Code 4) Vacuum Connection DIN 28403 KF16 / ISO 2861(Code 5) 1/4-NPT male thread(Code 6)
  • 18. EJCB- High Performance Pressure Transmitter General Specification www.bcstgroup.com 12 info@bcstgroup.com 7 Model and suffix codes High performance gauge pressure transmitter RP1002- High performance absolute pressure transmitter RP1003- 10 Accuracy A Reference Accuracy±0.05% 20 Span[1] P Gauge Pressure C 0-2kPa~40kPa / (0-200~4000 mmH2O) /(0-20~400mbar) D 0-2.5kPa~250kPa / (0-0.25~25 mH2O) /(0-25~2500mbar) F 0-30kPa~3MPa /(0-3~300 mH2O)/(0-0.3~30bar) G 0-0.1MPa~10MPa /(0-1~100bar) H 0-0.21MPa~21MPa /(0-2.1~210 bar) I 0-0.4MPa~40MPa /(0-4~400 bar) S 0-2kPa~40kPa /(0-200~4000 mmH2O)/(0-20~400mbar) 【Overload protection 7MPa】 A Absolute Pressure M 0-2.5kPa~250kPa /(0-25~2500mbar) O 0-30kPa~3MPa /(0-0.3~30bar) 30 Diaphragm fill fluid A 316L stainless steel Silicone oil B 316L stainless steel Fluorinated oil C Hastelloy C Silicone oil D Hastelloy C Fluorinated oil 40 Process connector accessory 1 1/2-NPT female thread 2 1/2-NPT male thread (Containing 1/4-NPT female thread) 3 M20x1.5 female thread 4 G 1/2 female thread 5 Vacuum Connection DIN 28403 KF16 / ISO 2861[2] 6 1/4-NPT male thread R Remote Seal 50 Special function N None 0 Degrease cleansing treatment(Oxygen measurement must be with fluorinated oil filled capsule, Viton (FKM) gasket, <6MPa ,<60℃) P Anti-lightning function 60 Mounting bracket N None 1 304 stainless steel 2 Carbon steel galvanized 70 Integral indicator N None 1 LCD display 2 Backlit LCD display 80 Explosion protected type
  • 19. EJCB- High Performance Pressure Transmitter General Specification www.bcstgroup.com 13 info@bcstgroup.com N None A Intrinsically safe Approval for NEPSI D Flameproof Approval for NEPSI B Intrinsically safe Approval for ATEX E Gas Flameproof Approval for ATEX G Dust Flameproof Approval for ATEX H Gas & Dust Flameproof Approval for ATEX 90 Tag name plate N None 1 Position number marked on the nameplate 2 Hanging stainless steel plate 100 Housing material A Aluminium alloy S Stainless Steel 110 Additional options(apply only to the range S)[3] N Perbunan(NBR) F Viton (FKM) P Teflon (PTFE) Note 1: EJCBP corresponding to select gauge pressure range code, EJCBA corresponding to select absolute pressure range code; Note 2:Vacuum Connection DIN 28403 KF16 / ISO 2861, applies only to the range of less than 2,5 bar; Note 3 :Additional options apply only to the range S, need to choose a suitable O-ring material according to the measuring medium,the default option is NBR. Order example: For example:EJCB1P-ACA1P11N1CN [EJCB1-]:High performance gauge pressure transmitter,Reference Accuracy:±0.05% [P]:Gauge Pressure [C]:Span:0-2kPa~40kPa /(0-200~4000 mmH2O)/(0-20~400mbar) [A]:316L stainless steel diaphragm, Silicone oil fill fluid [1]:1/2-NPT female thread process connector [P]:With anti-lightning function [1]:With 304 stainless steel mounting bracket [1]:With LCD display [N]:None of explosion protected type [1]:Position number marked on the nameplate [A]:Aluminium alloy
  • 20. EJCDP-B/C Differential Pressure Transmitter General Specifications www.bcstgroup.com 14 info@bcstgroup.com EJCDP-B Differential Pressure Transmitter EJCDP-C Differential Pressure Transmitter The differential pressure transmitter EJCDP-B/C is suitable to measure liquid, gas, or steam flow as well as liquid level, density and pressure. EJCDP- B/C outputs a 4~20mADC signal corresponding to the measured differential pressure. Its highly accurate and stable sensor can also measure the static pressure which can be shown on the integral indicator or remotely monitored via HART communications. Other key features include quick response, remote set-up using communications, self-diagnostics and optional status output for pressure high/low alarm. STANDARD SPECIFICATIONS 1 PERFORMANCE SPECIFICATIONS Reference Accuracy of Calibrated Span (includes terminal-based linearity, hysteresis, and repeatability) EJCDP-B:± 0.075%; EJCDP-C:± 0.1% If TD>10 (TD=URL/SPAN): EJCDP-B:±(0.0075×TD)%;EJCDP-C:±(0.01×TD)% The square root accuracy is 1.5 times of reference accuracy of calibrated span. Ambient Temperature Effects -20℃~65℃:±(0.15×TD+0.05)%×Span Every 10℃ is ±0.08% ×Span (TD=1) -40℃~-20℃ & 65℃~85℃:±(0.3×TD+0.1)%×Span Static Pressure Effects ±(0.05%URL+0.075%Span)/10MPa Overpressure Effects: ±0.1%×Span /10MPa。 Stability: ±0.1%×Span /3 years Power Supply Effects ±0.001% /10V (12~42V DC) 2 FUNCTIONAL SPECIFICATIONS Span and Range Limits Span/ Range Limits kPa inH2O mbar mmH2O B Span 0.2~6 0.8~24 2~60 20~600 Range Limits -6~6 -24~24 -60~ 60 -600~ 600 C Span 0.4~ 40 1.6~ 160 4~400 40~ 4000 Range Limits -40~ 40 -160~ 160 -400~ 400 -4000~ 4000 D Span 2.5~ 250 10~ 1000 25~ 2500 0.25~ 25mH2O Range Limits -250~ 250 -1000~ 1000 -2500 ~2500 -25~ 25mH2O F Span 30~ 3000 120~ 12000 0.3~ 30bar 3~ 300mH2O Range Limits -500~ 3000 -2000~ 12000 -5~ 30bar -5~ 300mH2O Zero Adjustment Limits Zero can be fully elevated or suppressed, within the lower and upper range limits of the capsule. External Zero Adjustment External zero is continuously adjustable with 0.01% incremental resolution of span. Re-range can be done locally using the range setting switch.
  • 21. EJCDP-B/C Differential Pressure Transmitter General Specifications www.bcstgroup.com 15 info@bcstgroup.com Mounting Position Effects Rotation in diaphragm plane has no effect. Tilting up to 90 degree will cause zero shift up to 0.4 kPa which can be corrected by the zero adjustment. Output Two wire 4~20mADC output with digital communications, linear or square root programmable. HART FSK protocol are superimposed on the 4~20 mADC signal. Output range: 3.9 mA to 20.5 mA. Failure Alarm (the mode can be selected) Low Mode (min): 3.7 mA High Mode (max): 21 mA No Mode (hold): Keep the effective value before the fault. Note: The standard setting of failure alarm is High Mode. Response Time The amplifier damping constant is 0.1 sec; The sensor damping constant is 0.1~1.6 sec, it depends on the range and range compression ratio. Amplifier damping time constant is adjustable from 0.1 to 60 sec by software and added to response time. UpTime < 15s Ambient Temperature Limits -40 to 85°C -20 to 65°C with LCD display or fluorine rubber sealing Storage and Transportation Temperature Limits -50 to 85°C; -40 to 85°C with LCD display Working Pressure Limits (Silicone oil) Maximum working pressure: 16MPa,25MPa,40MPa Static Pressure Limits 3.5kPa abs. to maximum working pressure. One-way Overload Pressure Limit The maximum one-way overload pressure is maximum working pressure. Electromagnetic Compatibility (EMC) Look the EMC Performance Table Explosion Protected Type NEPSI / ATEX: Ex dⅡC T6 NEPSI / ATEX: Ex iaⅡC T4 Amb. Temp.: -40℃~65℃ 3 INSTALL Supply & Load Requirements 24VDC supply, R ≤ (Us-12V)/Imax kΩ, Imax=23 mA. Maximum voltage limited: 42VDC, Minimum voltage limited: 12VDC, 15VDC(with LCD display) 230Ω to 600Ω for digital communication Electrical Connection The electrical connection is made via cable entry M20x1.5.The screw terminals are suitable for wire cross-sections up to 2.5mm2 . Process Connection Flange with fixing thread 7/16-20 UNF and 1/4-18 NPT female thread on both sides. 4 PHYSICAL SPECIFICATIONS Wetted Parts Materials Sensor Body: 316L stainless steel Isolating Diaphragm:316L stainless steel / Hastelloy C/Gold plated on 316L/FEP plated on 316L/Tantalum Cover Flange: 316 stainless steel Nuts and Bolts: 304 stainless steel Process Connector: 316 stainless steel Fill fluid: Silicone oil/Fluorinated oil Process Connector Gasket:Perbunan(NBR)/Viton (FKM)/Teflon(PTFE) Amplifier Housing: Aluminum with epoxy resin coat Housing Gasket: Perbunan(NBR) Name plate and tag:304 stainless steel Weight: 3.3kg Degrees of Protection: IP67
  • 22. EJCDP-B/C Differential Pressure Transmitter General Specifications www.bcstgroup.com 16 info@bcstgroup.com EMC Performance Table Items Test items Basic standards Test conditions Performance Level 1 Radiated interference (Housing) GB/T 9254-2008 30MHz~1000MHz OK 2 Conducted interference(DC power port) GB/T 9254-2008 0.15MHz~30MHz OK 3 Electrostatic Discharge (ESD) Immunity GB/T 17626.2-2006 4kV(Line) 8kV(Air) B 4 RF electromagnetic field immunity GB/T 17626.3-2006 10V/m (80MHz~1GHz) A 5 Frequency magnetic field immunity GB/T 17626.8-2006 30A/m A 6 Electrical Fast Transient Burst Immunity GB/T 17626.4-2008 2kV(5/50ns,5kHz) B 7 Surge Immunity GB/T 17626.5-2008 0.5kV(line to line) 1kV(line to ground) (1.2us/50us) B 8 Conducted interference immunity induced by RF field GB/T 17626.6-2008 3V (150KHz~80MHz) A Note:(1)Performance level A description: The technical specifications within the limits of normal performance. (2)Performance level B description: Temporary reduction or loss of functionality or performance, it can restore itself. The actual operating conditions, storage, and data will not be changed. DIMENSIONS Unit : mm Horizontal Impulse Piping Type(side face) Horizontal Impulse Piping Type(front side)
  • 23. EJCDP-B/C Differential Pressure Transmitter General Specifications www.bcstgroup.com 17 info@bcstgroup.com Horizontal Impulse Wall mounting Type Vertical Impulse Piping Type 5 Terminal Configuration 6 Vertical mounting flange (Code V) Note:Quick interface functionally equivalent to the signal terminal 7 Process connections Description
  • 24. EJCDP-B/C Differential Pressure Transmitter General Specifications www.bcstgroup.com 18 info@bcstgroup.com 8 Model and suffix codes Differential Pressure Transmitter EJCDP- 10 Accuracy B Reference Accuracy±0.075% C Reference Accuracy±0.1% 20 Span B 0-200Pa~6kPa(0-20~600 mmH2O)/(0-2~60mbar) C 0-400Pa~40kPa(0-40~4000 mmH2O)/(0-20~400mbar) D 0-2.5kPa~250kPa(0-0.25~25 mH2O)/(0-25~2500mbar) F 0-30kPa~3MPa(0-3~300 mH2O)/(0-0.3~30bar) 30 Static pressure sensor 0 None 1 40MPa 2 10MPa 40 Diaphragm fill fluid A 316L stainless steel Silicone oil B 316L stainless steel Fluorinated oil C Hastelloy C Silicone oil D Hastelloy C Fluorinated oil E Gold plated on 316L Silicone oil F Gold plated on 316L Fluorinated oil G FEP plated on 316L Silicone oil T Tantalum Silicone oil 50 Working pressure 1 16MPa 2 25MPa 3 40MPa 60 Process connections N 7/16-20 UNF and 1/4-18 NPT female thread, No relief valve B 7/16-20 UNF and 1/4-18 NPT female thread, Relief valves at end of flanges U 7/16-20 UNF and 1/4-18 NPT female thread, Relief valves at the upper part of the flange side D 7/16-20 UNF and 1/4-18 NPT female thread, Relief valve at the lower part of the flange side V Vertical mounting flange, 7/16-20 UNF and 1/4-18 NPT female thread, Relief valves at the upper part of the flange side L Level(Low side can select : B/ U/ D) R Remote Seal 70 Process connector gasket N Perbunan(NBR) F Viton (FKM) P Teflon (PTFE) 80 Special function N None
  • 25. EJCDP-B/C Differential Pressure Transmitter General Specifications www.bcstgroup.com 19 info@bcstgroup.com F Square root output O Degrease cleansing treatment(Oxygen measurement must be with fluorinated oil filled capsule, Viton (FKM) gasket, <6MPa ,<60℃) P Anti-lightning function 90 Mounting bracket N None 1 304 stainless steel 2 Carbon steel galvanized 100 Process connector accessory N None 1 Stainless steel oval-shaped flange with 1/2 NPT female thread 2 Stainless steel D-shaped connector with M20x1.5 male thread 110 Integral indicator N None 1 LCD display 2 Backlit LCD display 120 Explosion protected type N None A Intrinsically safe Approval for NEPSI D Flameproof Approval for NEPSI B Intrinsically safe Approval for ATEX E Gas Flameproof Approval for ATEX G Dust Flameproof Approval for ATEX H Gas & Dust Flameproof Approval for ATEX 130 Tag name plate N None 1 Position number on the nameplate 2 Hanging stainless steel plate 140 Manual C Chinese E English Order example:For example:EJCDP-BC2A1BNF111N1C [B]:Reference Accuracy:±0.075% [1]:With 304 stainless steel mounting bracket [C]:Span:0-400Pa~40kPa(0-40~4000 mmH2O) [1]:With stainless steel oval-shaped flange [2]:Static pressure sensor:10MPa with 1/2 NPT female thread [A]:316L stainless steel diaphragm, Silicone oil fill fluid [1]:With LCD display [1]:Working pressure:16MPa [N]:None of explosion protected type [B]:7/16-20 UNF and 1/4-18 NPT female thread, [1]:Position number marked on the nameplate Relief valves at end of flanges [C]:Chinese manual [N]:Perbunan(NBR)process connector gasket [F]:Square root output
  • 26. EJCBP Pressure Transmitter General Specifications www.bcstgroup.com 20 BCST Group Co.,Ltd EJCBP Gauge Pressure Transmitter EJCBA Absolute Pressure Transmitter The pressure transmitter EJCBP/BA is suitable to measure liquid, gas, or steam flow as well as liquid level, density and pressure. RP1002/3-B/C outputs a 4~20mADC signal corresponding to the measured pressure. The key features include quick response, remote set-up using communications, self-diagnostics and optional status output for pressure high/low alarm. STANDARD SPECIFICATIONS 1 PERFORMANCE SPECIFICATIONS Reference Accuracy of Calibrated Span (includes terminal-based linearity, hysteresis, and repeatability) RP1001-B:± 0.075%; RP1001-C:± 0.1% If TD>10 (TD=URL/SPAN): EJCBP:±(0.0075×TD)%; EJCBA:±(0.01×TD)% Ambient Temperature Effects -20℃~65℃: ±(0.15×TD+0.05)%×Span Every 10℃ is ±0.08% ×Span (TD=1) -40℃~-20℃ & 65℃~85℃: ±(0.2×TD+0.05)%×Span Overpressure Effects ±0.05%×Span Stability ±0.1%×Span /3 years Power Supply Effects: ±0.001% /10V (12~42V DC) 2 FUNCTIONAL SPECIFICATIONS Span and Range Limits (RP1002-B/C) Span/ Range Limits kPa psi bar Kgf/cm2 B/ R Span 0.6~6 0.087 ~0.87 6~60 mbar 0.006 ~0.06 Range Limits -6~6 -0.87~ 0.87 -60~ 60 mbar -0.06 ~0.06 C /S Span 2~40 0.29~ 5.8 0.02~ 0.4 0.02~ 0.4 Range Limits -40~ 40 -5.8~ 5.8 -0.4~ 0.4 -0.4~ 0.4 D Span 2.5~ 250 0.3625 ~ 36.25 0.025 ~2.5 0.025 ~2.5 Range Limits -100~ 250 -14.5~ 36.25 -1~ 2.5 -1~ 2.5 F Span 30~ 3000 4.35~ 435 0.3~ 30 0.3~ 30 Range Limits -100~ 3000 -14.5~ 435 -1~30 -1~30 G Span 0.1~ 10MPa 14.5~ 1450 1~ 100 1~100 Range Limits -0.1~ 10MPa -14.5~ 1450 -1~ 100 -1~ 100 H Span 0.21~ 21 MPa 30.45 ~3045 2.1~ 210 2.1~ 210 Range Limits -0.1~ 21 MPa -14.5~ 8000 -1~ 210 -1~ 210
  • 27. EJCBP Pressure Transmitter General Specifications www.bcstgroup.com 21 BCST Group Co.,Ltd I Span 0.4~ 40 MPa 58~ 5800 4~ 400 4~ 400 Range Limits -0.1~ 40 MPa -14.5~ 5800 -1~ 400 -1~ 400 Span and Range Limits (RP1003-B/C) Span/ Range Limits kPa psi bar Kgf/cm2 L/ T Span 2~ 40 0.29~ 5.8 0.02~ 0.4 0.02~ 0.4 Range Limits 0~ 40 0~5.8 0~0.4 0~0.4 M Span 2.5~ 250 0.3625 ~36.25 0.025 ~2.5 0.025 ~2.5 Range Limits 0~ 250 0~ 36.25 0~2.5 0~2.5 O Span 30~ 3000 4.35~ 435 0.3~ 30 0.3~ 30 Range Limits 0~ 3000 0~435 0~30 0~30 External Zero Adjustment External zero is continuously adjustable with 0.01% incremental resolution of span. Re-range can be done locally using the range setting switch. Mounting Position Effects Rotation in diaphragm plane has no effect. Tilting up to 90° will cause zero shift up to 0.25kPa which can be corrected by the zero adjustment. Output Two wire 4~20mADC output with digital communications, linear or square root programmable. HART FSK protocol are superimposed on the 4~20 mADC signal. Output range: 3.9 mA to 20.5 mA Failure Alarm (the mode can be selected) Low Mode (min): 3.7 mA, High Mode (max): 21 mA No Mode (hold): Keep the effective value before fault. The standard setting of failure alarm is High Mode. Response Time The amplifier damping constant is 0.1 sec; The sensor damping constant is 0.1~1.6 sec, it depends on the range and range compression ratio. Amplifier damping time constant is adjustable from 0.1 to 60 sec by software and added to response time. Up Time < 15s Ambient Temperature Limits: -40 to 85°C -20 to 65°C with LCD display or fluorine rubber sealing Storage and Transportation Temperature Limits -50 to 85°C, -40 to 85°C with LCD display Working Pressure Limits (Silicone oil) From vacuum to upper range limits Overload Pressure Limits Span 40kPa 250kPa (D/M) 3MPa (F/O) (C) (S) OPL 1MPa 7MPa 4MPa 15MPa Span 10MPa(G) 21MPa(H) 40MPa(I) OPL 20MPa 50MPa 50MPa Electromagnetic Compatibility (EMC) Look the EMC Performance Table Explosion Protected Type NEPSI / ATEX: Ex dⅡC T6, NEPSI / ATEX: Ex iaⅡC T4 Amb. Temp.: -40℃~65℃ 3 INSTALL Supply & Load Requirements 24VDC supply, R ≤ (Us-12V)/Imax kΩ, Imax=23 mA. Maximum voltage limited: 42VDC, Minimum voltage limited: 12VDC, 15VDC(with LCD display) 230Ω to 600Ω for digital communication Electrical Connection The electrical connection is made via cable entry M20x1.5.The screw terminals are suitable for wire cross-sections up to 2.5mm2 . Process Connection Default Process Connection:1/2-NPT female thread, it
  • 28. EJCBP Pressure Transmitter General Specifications www.bcstgroup.com 22 BCST Group Co.,Ltd can be changed to 1/2-NPT,G1/2,M20x1.5male thread and KF16 vacuum Connection. 4 PHYSICAL SPECIFICATIONS Isolating Diaphragm: 316L stainless steel/Hastelloy C Process Connector: 316 stainless steel Fill fluid: Silicone oil/Fluorinated oil Amplifier Housing: Aluminum with epoxy resin coat Housing Gasket: Perbunan(NBR) Name plate and tag:304 stainless steel Weight: 1.6kg Degrees of Protection: IP67 EMC Performance Table Items Test items Basic standards Test conditions Performance Level 1 Radiated interference (Housing) GB/T 9254-2008 30MHz~1000MHz OK 2 Conducted interference(DC power port) GB/T 9254-2008 0.15MHz~30MHz OK 3 Electrostatic Discharge (ESD) Immunity GB/T 17626.2-2006 4kV(Line) 8kV(Air) B 4 RF electromagnetic field immunity GB/T 17626.3-2006 10V/m (80MHz~1GHz) A 5 Frequency magnetic field immunity GB/T 17626.8-2006 30A/m A 6 Electrical Fast Transient Burst Immunity GB/T 17626.4-2008 2kV(5/50ns,5kHz) B 7 Surge Immunity GB/T 17626.5-2008 0.5kV(line to line) 1kV(line to ground) (1.2us/50us) B 8 Conducted interference immunity induced by RF field GB/T 17626.6-2008 3V (150KHz~80MHz) A Note:(1)Performance level A description: The technical specifications within the limits of normal performance. (2)Performance level B description: Temporary reduction or loss of functionality or performance, it can restore itself. The actual operating conditions, storage, and data will not be changed. DIMENSIONS Unit : mm Horizontal Impulse Piping Type(side face) Horizontal Impulse Piping Type(front side)
  • 29. EJCBP/BA Pressure Transmitter General Specifications www.bcstgroup.com 23 BCST Group Co.,Ltd Horizontal Impulse Wall mounting Type Vertical Impulse Piping Type 5 Terminal Configuration Note:Quick interface functionally equivalent to the signal terminal 6 Process connections Description 6.1 Default Process Connection(Code 1) F/G/H/I/O Span B/C/R/S/L/T/M/D Span
  • 30. EJCBP/BA Pressure Transmitter General Specifications www.bcstgroup.com 24 BCST Group Co.,Ltd 6.2 Other forms of Process connector 1/2-NPT male thread(Code 2) M20x1.5 male thread(Code3) G 1/2 male thread(Code 4) Vacuum Connection DIN 28403 KF16 / ISO 2861(Code 5) 1/4-NPT male thread(Code 6)
  • 31. EJCBP/BA Pressure Transmitter General Specifications www.bcstgroup.com 25 BCST Group Co.,Ltd 7 Model and suffix codes Gauge Pressure Transmitter EJCBP - Absolute Pressure Transmitter EJCBA - 10 Accuracy 1 Reference Accuracy±0.075% 2 Reference Accuracy±0.1% 20 Span[1] P Gauge Pressure B 0-0.6kPa~6kPa /(0-60~600 mmH2O)/(0-6~60mbar) C 0-2kPa~40kPa / (0-200~4000 mmH2O) /(0-20~400mbar) D 0-2.5kPa~250kPa / (0-0.25~25 mH2O) /(0-25~2500mbar) F 0-30kPa~3MPa /(0-3~300 mH2O)/(0-0.3~30bar) G 0-0.1MPa~10MPa /(0-1~100bar) H 0-0.21MPa~21MPa /(0-2.1~210 bar) I 0-0.4MPa~40MPa /(0-4~400 bar) R 0-0.6kPa~6kPa /(0-60~600 mmH2O)/(0-6~60mbar) 【Overload protection 7MPa】 S 0-2kPa~40kPa /(0-200~4000 mmH2O)/(0-20~400mbar) 【Overload protection 7MPa】 A Absolute Pressure L 0-2kPa~40kPa /(0-200~4000 mmH2O)/(0-20~400mbar) M 0-2.5kPa~250kPa /(0-25~2500mbar) O 0-30kPa~3MPa /(0-0.3~30bar) T 0-2kPa~40kPa /(0-200~4000 mmH2O)/(0-20~400mbar) 【Overload protection 7MPa】 30 Diaphragm fill fluid A 316L stainless steel Silicone oil B 316L stainless steel Fluorinated oil C Hastelloy C Silicone oil D Hastelloy C Fluorinated oil 40 Process connector accessory 1 1/2-NPT female thread 2 1/2-NPT male thread (Containing 1/4-NPT female thread) 3 M20x1.5 female thread 4 G 1/2 female thread 5 Vacuum Connection DIN 28403 KF16 / ISO 2861[2] 6 1/4-NPT male thread R Remote Seal 50 Special function N None 0 Degrease cleansing treatment(Oxygen measurement must be with fluorinated oil filled capsule, Viton (FKM) gasket, <6MPa ,<60℃) P Anti-lightning function 60 Mounting bracket N None 1 304 stainless steel 2 Carbon steel galvanized
  • 32. EJCBP/BA Pressure Transmitter General Specifications www.bcstgroup.com 26 BCST Group Co.,Ltd 70 Integral indicator N None 1 LCD display 2 Backlit LCD display 80 Explosion protected type N None A Intrinsically safe Approval for NEPIS D Flameproof Approval for NEPSI B Intrinsically safe Approval for ATEX E Gas Flameproof Approval for ATEX G Dust Flameproof Approval for ATEX H Gas & Dust Flameproof Approval for ATEX 90 Tag name plate N None 1 Position number marked on the nameplate 2 Hanging stainless steel plate 100 Housing material A Aluminium alloy S 316SS 110 Additional options(apply only to the range R/S/T)[3] N Perbunan(NBR) F Viton (FKM) P Teflon (PTFE) Note 1 : EJCBP corresponding to select gauge pressure range code, RP1003 corresponding to select absolute pressure range code; Note 2:Vacuum Connection DIN 28403 KF16 / ISO 2861, applies only to the range of less than 2,5 bar; Note 3:Additional options apply only to the range R/S/T, need to choose a suitable O-ring material according to the measuring medium,the default option is NBR. Order example: For example:EJCBP -BCA1P11N1CN [RP1002-]:Gauge pressure transmitter [B]:Reference Accuracy:±0.075% [C]:Span:0-2kPa~40kPa /(0-200~4000 mmH2O)/(0-20~400mbar) [A]:316L stainless steel diaphragm, Silicone oil fill fluid [1]:1/2-NPT female thread process connector [P]:With anti-lightning function [1]:With 304 stainless steel mounting bracket [1]:With LCD display [N]:None of explosion protected type [1]:Position number marked on the nameplate [A]:Aluminium alloy
  • 33. EJC Micro-differential pressure transmitter General Specifications www.bcstgroup.com 27 BCST Group Co.,Ltd EJCDM Micro-differential Pressure Transmitter The micro-differential pressure transmitter EJCDM is suitable to measure liquid, gas, or steam flow as well as liquid level, density and pressure. EJCDM - outputs a 4~20mADC signal corresponding to the measured differential pressure. Its highly accurate and stable sensor can also measure the static pressure which can be shown on the integral indicator or remotely monitored via HART communications. Other key features include quick response, remote set-up using communications, self-diagnostics and optional status output for pressure high/low alarm. STANDARD SPECIFICATIONS 1 PERFORMANCE SPECIFICATIONS Reference Accuracy of Calibrated Span (includes terminal-based linearity, hysteresis, and repeatability) EJCDM-B:± 0.075%; EJCDM-C:± 0.1% EJCDM-D:± 0.25% If TD>2.5 (TD= URL/SPAN), EJCDM-B: ±(0.03×TD)%; EJCDM-C: ±(0.04×TD)% EJCDM-D:±(0.1×TD)% The square root accuracy is 1.5 times of reference accuracy of calibrated span. Ambient Temperature Effects EJCDM-B/C: -20℃~65℃ ±(0.25×TD+0.15)%×Span Every 10℃ is ±0.08% ×Span (TD=1) -40℃~-20℃ & 65℃~85℃: ±(0.25×TD+0.15)%×Span EJCDM-D: -20℃~65℃:±(0.35×TD+0.15)%×Span Every 10℃ is ±0.16% ×Span (TD=1) -40℃~-20℃ & 65℃~85℃: ±(0.35×TD+0.15)%×Span Overpressure Effects: ±0.1%×Span Static Pressure Effects EJCDM-B/C: ±(0.05%URL+0.075%Span)/Working Pressure EJCDM-D: ±(0.1%URL+0.15%Span)/Working Pressure Stability:Reference Accuracy ×Span /3 years Power Supply Effects: ±0.001% /10V (12~42V DC) 2 FUNCTIONAL SPECIFICATIONS Span and Range Limits Span/ Range Limits kPa inH2O mbar mmH2 O A0/ A7 Span 0.1 ~1 0.4~4 1~10 10~ 100 Range Limits -1~ 1 -4~4 -10~ 10 -100~ 100 Zero Adjustment Limits Zero can be fully elevated or suppressed, within the lower and upper range limits of the capsule. External Zero Adjustment External zero is continuously adjustable with 0.01% incremental resolution of span. Re-range can be done locally using the range setting switch. Mounting Position Effects
  • 34. EJC Micro-differential pressure transmitter General Specifications www.bcstgroup.com 28 BCST Group Co.,Ltd Rotation in diaphragm plane has no effect. Tilting up to 90 degree will cause zero shift up to 0.4 kPa which can be corrected by the zero adjustment. Output Two wire 4~20mADC output with digital communications, linear or square root programmable. HART FSK protocol are superimposed on the 4~20 mADC signal. Output range: 3.9 mA to 20.5 mA. Failure Alarm (the mode can be selected) Low Mode (min): 3.7 mA High Mode (max): 21 mA No Mode (hold): Keep the effective value before the fault. Note: The standard setting of failure alarm is High Mode. Response Time The amplifier damping constant is 0.1 sec; The sensor damping constant is 0.1~1.6 sec, it depends on the range and range compression ratio. Amplifier damping time constant is adjustable from 0.1 to 60 sec by software and added to response time. UpTime < 15s Ambient Temperature Limits -40 to 85°C -20 to 65°C with LCD display or fluorine rubber sealing Storage and Transportation Temperature Limits -50 to 85°C -40 to 85°C with LCD display Working Pressure Limits (Silicone oil) Maximum working pressure:0.2MPa,7MPa Static Pressure Limits 3.5kPa abs. to maximum working pressure. One-way Overload Pressure Limit The maximum one-way overload pressure is maximum working pressure. Electromagnetic Compatibility (EMC) Look the EMC Performance Table Explosion Protected Type NEPSI / ATEX: Ex dⅡC T6 NEPSI / ATEX: Ex iaⅡC T4 Amb. Temp.: -40℃~65℃ 3 INSTALL Supply & Load Requirements 24VDC supply, R ≤ (Us-12V)/Imax kΩ, Imax=23 mA. Maximum voltage limited: 42VDC, Minimum voltage limited: 12VDC, 15VDC(with LCD display) 230Ω to 600Ω for digital communication Electrical Connection The electrical connection is made via cable entry M20x1.5.The screw terminals are suitable for wire cross-sections up to 2.5mm2 . Process Connection Flange with fixing thread 7/16-20 UNF and 1/4-18 NPT female thread on both sides. 4 PHYSICAL SPECIFICATIONS Wetted Parts Materials Sensor Body: 316L stainless steel Isolating Diaphragm:316L stainless steel / Hastelloy C/Gold plated on 316L Cover Flange: 316 stainless steel Nuts and Bolts: 304 stainless steel Process Connector: 316 stainless steel Fill fluid: Silicone oil/Fluorinated oil Process Connector Gasket:Perbunan(NBR)/Viton (FKM)/Teflon(PTFE) Amplifier Housing: Aluminum with epoxy resin coat Housing Gasket: Perbunan(NBR) Name plate and tag:304 stainless steel Weight: 3.3kg Degrees of Protection: IP67
  • 35. EJC Micro-differential pressure transmitter General Specifications www.bcstgroup.com 29 BCST Group Co.,Ltd EMC Performance Table Items Test items Basic standards Test conditions Performance Level 1 Radiated interference (Housing) GB/T 9254-2008 30MHz~1000MHz OK 2 Conducted interference(DC power port) GB/T 9254-2008 0.15MHz~30MHz OK 3 Electrostatic Discharge (ESD) Immunity GB/T 17626.2-2006 4kV(Line) 8kV(Air) B 4 RF electromagnetic field immunity GB/T 17626.3-2006 10V/m (80MHz~1GHz) A 5 Frequency magnetic field immunity GB/T 17626.8-2006 30A/m A 6 Electrical Fast Transient Burst Immunity GB/T 17626.4-2008 2kV(5/50ns,5kHz) B 7 Surge Immunity GB/T 17626.5-2008 0.5kV(line to line) 1kV(line to ground) (1.2us/50us) B 8 Conducted interference immunity induced by RF field GB/T 17626.6-2008 3V (150KHz~80MHz) A Note:(1)Performance level A description: The technical specifications within the limits of normal performance. (2)Performance level B description: Temporary reduction or loss of functionality or performance, it can restore itself. The actual operating conditions, storage, and data will not be changed. DIMENSIONS Unit : mm Horizontal Impulse Piping Type(side face) Horizontal Impulse Piping Type(front side)
  • 36. EJC Micro-differential pressure transmitter General Specifications www.bcstgroup.com 30 BCST Group Co.,Ltd Horizontal Impulse Wall mounting Type Vertical Impulse Piping Type 5 Terminal Configuration Note:Quick interface functionally equivalent to the signal terminal 6 Process connections Description
  • 37. EJC Micro-differential pressure transmitter General Specifications www.bcstgroup.com 31 BCST Group Co.,Ltd 7 Model and suffix codes Micro-differential Pressure Transmitter EJCDM- 10 Accuracy B Reference Accuracy±0.075% C Reference Accuracy±0.1% D Reference Accuracy±0.25% 20 Span A0 0-100Pa~1kPa(0-10~100 mmH2O)working pressure 0.2MPa A7 0-100Pa~1kPa(0-10~100 mmH2O)working pressure 7MPa 30 Static pressure sensor 0 None 1 250kPa(apply only to 0.2MPa working pressure) 2 10MPa (apply only to 7MPa working pressure) 40 Diaphragm fill fluid A 316L stainless steel Silicone oil B 316L stainless steel Fluorinated oil C Hastelloy C Silicone oil D Hastelloy C Fluorinated oil E Gold plated on 316L Silicone oil F Gold plated on 316L Fluorinated oil 50 Process connections N 7/16-20 UNF and 1/4-18 NPT female thread, No relief valve B 7/16-20 UNF and 1/4-18 NPT female thread, Relief valves at end of flanges U 7/16-20 UNF and 1/4-18 NPT female thread, Relief valves at the upper part of the flange side D 7/16-20 UNF and 1/4-18 NPT female thread, Relief valve at the lower part of the flange side 60 Process connector gasket N Perbunan(NBR) F Viton (FKM) P Teflon (PTFE) 70 Special function N None F Square root output O Degrease cleansing treatment(Oxygen measurement must be with fluorinated oil filled capsule, Viton (FKM) gasket, <6MPa ,<60℃) P Anti-lightning function 80 Mounting bracket N None 1 304 stainless steel 2 Carbon steel galvanized 90 Process connector accessory N None 1 Stainless steel oval-shaped flange with 1/2 NPT female
  • 38. EJC Micro-differential pressure transmitter General Specifications www.bcstgroup.com 32 BCST Group Co.,Ltd thread 2 Stainless steel D-shaped connector with M20x1.5 male thread 100 Integral indicator N None 1 LCD display 2 Backlit LCD display 110 Explosion protected type N None A Intrinsically safe standard ,Ex iaⅡC T4 D Explosion-proof ,Ex dⅡC T6, 120 Tag name plate N None 1 Position number marked on the nameplate 2 Hanging stainless steel plate 130 Housing material A Aluminium alloy S 316SS Order example: For example:EJCDM-BA02ABNF111N1C [B]:Reference Accuracy:±0.075% [A0]:0-100Pa~1kPa(0-10~100 mmH2O)working pressure 0.2MPa [2]:Static pressure sensor:10MPa [A]:316L stainless steel diaphragm, Silicone oil fill fluid [B]:7/16-20 UNF and 1/4-18 NPT female thread, Relief valves at end of flanges [N]:Perbunan(NBR)process connector gasket [F]:Square root output [1]:With 304 stainless steel mounting bracket [1]:With stainless steel oval-shaped flange with 1/2 NPT female thread [1]:With LCD display [N]:None of explosion protected type [1]:Position number marked on the nameplate [A]:Aluminium alloy
  • 39. EJC Differential Pressure Level Transmitter General Specifications www.bcstgroup.com 33 BCST Group Co.,Ltd EJCLT Differential Pressure Level Transmitter 1 Application The differential pressure level transmitter EJCLT is suitable to measure liquid, gas, or steam flow as well as liquid level, density and pressure. EJCLT outputs a 4~20mADC signal corresponding to the measured differential pressure. Its highly accurate and stable sensor can also measure the static pressure which can be shown on the integral indicator or remotely monitored via HART communications. Other key features include quick response, remote set-up using communications, self-diagnostics and optional status output for pressure high/low alarm. The range Limits is 0—1kPa ~ 2MPa, The flange’s working pressure are 1.6/4MPa,6.4MPa,10MPa,150psi,300psi or 600psi. 2 Operation Theory and Structure EJCLT differential pressure level transmitter is composed of EJCLT series differential pressure transmitter and the welding installation level flange. The operation theory is the same as EJCLT series differential pressure transmitter (consult EJCLT series differential pressure transmitter general specifications), Only the high pressure side of pressure transmission path is different. The pressure Loaded in the high side, pass from the isolation diaphragm and silicone oil in the flange to the sensor. 3 Input Measured value: Differential pressure, Level Measuring range Lower range value: -100% to +100% of the URL(continuously adjustable) Upper range value: Up to 100% of the URL(continuously adjustable) Spans Table 1:Span code, measuring range and SWP Span code Measuring range SWP(Max) Min Max B 1kPa 6kPa The flange’s working pressure C 4kPa 40kPa D 25kPa 250kPa F 200kPa 3MPa Table 2: Flange and minimum measuring range The minimum measuring range of the differential pressure Level transmitter should be the larger value of the minimum range of table 1 and table 2.The adjusted span must not be lower than the minimum range. 4 Output Output signal Two wire 4~20mADC output with digital communications, linear or square root programmable. HART FSK protocol are superimposed on the 4~20 mADC signal. Output range: 3.9 mA to 20.5 mA. Failure Alarm (the mode can be selected) Low Mode (min): 3.7 mA, High Mode (max): 21 mA Flange Nominal diameter The minimum measuring range Bulge sealing DN 50/2” 10kPa DN 80/3” 2kPa DN 4” 2kPa Flat sealing DN 50/2” 16kPa DN 80/3” 2kPa DN 4” 2kPa
  • 40. EJC Differential Pressure Level Transmitter General Specifications www.bcstgroup.com 34 BCST Group Co.,Ltd No Mode (hold): Keep the effective value before the fault. Note: The standard setting of failure alarm is High Mode. 5 Response Time The amplifier damping constant is 0.1 sec; The sensor and flange’s damping constant is 0.2~3 sec, it depends on the range and range compression ratio. Amplifier damping time constant is adjustable from 0.1 to 60 sec by software and added to response time. 6 General conditions 6.1 Installation conditions The transmitter can be directly flanged in any position. Preferably in such a position that the process flange axes are vertical. Deviations from this can cause a shift in the zero, which can be corrected. The electronic housing can be rotated through 360°and can be fixed in any position. A stop prevents the housing being turned too far. 6.2 Ambient conditions Ambient temperature Min:depends on the fill fluid Max:85℃ -20~65℃,with LCD-indicator Storage temperature/transport temperature Min:depends on the fill fluid Max:85℃ Humidity:0~100% Shock resistant: Acceleration:50g,Duration:11ms Vibration resistance: 500Hz on 2g Electromagnetic Compatibility (EMC) Look the EMC Performance Table 3 6.3 Process conditions Temperature limits:-30~180℃ Pressure limits: From 3.5kPa abs. to working pressure. Proof pressure up to 1.5-times the nominal pressure simultaneously on both sides of the transmitter admissible. Flange working pressure ANSI:150psi~600psi DIN: PN 1.6MPa~PN 10MPa One-sided overload: One-sided overload up to the rated pressure. Possibly occurring zero offsets can be corrected. Weight:DN 50/2”about 7~10kg;DN 80/3” about 8~ 11kg;DN 4” about 9~12kg Explosion Protected Type NEPSI / ATEX: Ex dⅡC T6 NEPSI / ATEX: Ex iaⅡC T4 Amb. Temp.: -40℃~65℃ 6.4 Supply & Load Requirements 24VDC supply, R≤(Us-12V)/Imax kΩ, Imax=23 mA. Maximum voltage limited: 42VDC, Minimum voltage limited: 12VDC, 15VDC(with LCD display) 230Ω to 600Ω for digital communication Wetted Parts Materials Flange: 316 stainless steel Isolating Diaphragm:316L stainless steel / Hastelloy C/FEP or PFA plated on 316L/Tantalum Nuts and Bolts: 304 stainless steel Process Connector: 316 stainless steel Fill fluid: Silicone oil/ Vegetable oil Process Connector Gasket:Perbunan(NBR)/Viton (FKM)/Teflon(PTFE) Amplifier Housing: Aluminum with epoxy resin coat Housing Gasket: Perbunan(NBR) Name plate and tag:304 stainless steel Degrees of Protection: IP67 Electrical Connection The electrical connection is made via cable entry M20x1.5.The screw terminals are suitable for wire cross-sections up to 2.5mm2 . Process Connection Flange with fixing thread 7/16-20 UNF and 1/4-18 NPT female thread on both sides. The level flange comply with the ANSI standard or DIN standards.
  • 41. EJC Differential Pressure Level Transmitter General Specifications www.bcstgroup.com 35 BCST Group Co.,Ltd Table 3 : EMC Performance Table Items Test items Basic standards Test conditions Performance Level 1 Radiated interference (Housing) GB/T 9254-2008 30MHz~1000MHz OK 2 Conducted interference(DC power port) GB/T 9254-2008 0.15MHz~30MHz OK 3 Electrostatic Discharge (ESD) Immunity GB/T 17626.2-2006 4kV(Line) 8kV(Air) B 4 RF electromagnetic field immunity GB/T 17626.3-2006 10V/m (80MHz~1GHz) A 5 Frequency magnetic field immunity GB/T 17626.8-2006 30A/m A 6 Electrical Fast Transient Burst Immunity GB/T 17626.4-2008 2kV(5/50ns,5kHz) B 7 Surge Immunity GB/T 17626.5-2008 0.5kV(line to line) 1kV(line to ground) (1.2us/50us) B 8 Conducted interference immunity induced by RF field GB/T 17626.6-2008 3V (150KHz~80MHz) A Note:(1)Performance level A description: The technical specifications within the limits of normal performance. (2)Performance level B description: Temporary reduction or loss of functionality or performance, it can restore itself. The actual operating conditions, storage, and data will not be changed. DIMENSIONS Unit : mm
  • 42. EJC Differential Pressure Level Transmitter General Specifications www.bcstgroup.com 36 BCST Group Co.,Ltd Table 4: Level flange dimensions Nominal diameter Working pressure ΦD ΦK Φd1 Φd2 Φd3 t b Bolt Bulge seal Flat seal DN 50 PN1.6/4MPa 165 125 48.3 57 102 3+0.5 20 4 M16 (Sealing DIN 2526E) PN 6.4MPa 18 135 48.3 57 102 3+0.5 26 4 M20 (Flange DIN 2501) PN 10MPa 195 145 48.3 57 102 3+0.5 28 4 M20 DN 80 PN1.6/4MPa 200 160 76 75 138 3+0.5 24 8 M16 (Sealing DIN 2526E) PN 6.4MPa 215 170 76 75 138 3+0.5 28 8 M20 (Flange DIN 2501) PN 10MPa 230 180 76 75 138 3+0.5 32 8 M24 DN 2" (ANSI B 16.5 RF) 150psi 152.4 120.6 48.3 57 92.1 3+0.5 17.4 4 M18 300psi 165.1 127.0 48.3 57 92.1 3+0.5 20.6 8 M18 600psi 165.1 127.0 48.3 57 92.1 6.35 31.75 8 M18 DN 3" (ANSI B 16.5 RF) 150psi 190.5 152.4 76 75 127 3+0.5 22.2 4 M16 300psi 209.5 168.3 76 75 127 3+0.5 27.0 8 M20 600psi 209.5 168.3 76 75 127 6.35 38.05 8 M20 DN 4“ 150psi 229 191 89 89 157 3+0.5 30 8 M18 (ANSI B 16.5 RF) 300psi 255 200 89 89 157 3+0.5 32 8 M18 7 Terminal Configuration Note:Quick interface functionally equivalent to the signal terminal 8 Process Connections Description
  • 43. EJC Differential Pressure Level Transmitter General Specifications www.bcstgroup.com 37 BCST Group Co.,Ltd 9 Model and suffix codes [1] Level flange sealing device selection of the differential pressure Level transmitter EJCLT 10 Flange sealing device LT- Level flange sealing, no capillary ,⊕ Side 20 Process connection, Flange and diaphragm material A DN50 DIN 2501 E DN2526 316L stainless steel B DN50 DIN 2501 E DN2526 Hastelloy C C DN50 DIN 2501 E DN2526 Tantalum H DN80 DIN 2501 E DN2526 316L stainless steel I DN80 DIN 2501 E DN2526 Hastelloy C G DN80 DIN 2501 E DN2526 Tantalum D DN2″ANSI B 16.5 RF ANSI B 16.5 316L stainless steel E DN2″ANSI B 16.5 RF ANSI B 16.5 Hastelloy C F DN2″ANSI B 16.5 RF ANSI B 16.5 Tantalum K DN3″ANSI B 16.5 RF ANSI B 16.5 316L stainless steel L DN3″ANSI B 16.5 RF ANSI B 16.5 Hastelloy C M DN3″ANSI B 16.5 RF ANSI B 16.5 Tantalum N DN4″ANSI B 16.5 RF ANSI B 16.5 316L stainless steel O DN4″ANSI B 16.5 RF ANSI B 16.5 Hastelloy C P DN4″ANSI B 16.5 RF ANSI B 16.5 Tantalum 30 Working pressure 1 PN 1MPa/4MPa DIN 2501 2 PN 6.4MPa DIN 2501 3 PN 10MPa DIN 2501 6 150# ANSI B 16.5 7 300# ANSI B 16.5 8 600# ANSI B 16.5(not including DN4″ANSI B 16.5) 40 Flange sealing type F Flat sealing H Bulge sealing,316L stainless steel,extended diaphragm seal 50mm I Bulge sealing,316L stainless steel,extended diaphragm seal 100mm G Bulge sealing,316L stainless steel,extended diaphragm seal 150mm L Bulge sealing,Hastelloy C, extended diaphragm seal 50mm M Bulge sealing,Hastelloy C, extended diaphragm seal 100mm N Bulge sealing,Hastelloy C, extended diaphragm seal 150mm 50 Fill fluid S Silicone oil -40~200℃ V Vegetable oil 0~250℃ 60 Diaphragm Protection N None 1 FEP plated on 316L, ≤180℃ 2 PFA plated on 316L, ≤260℃ 3 PTFE coated on 316L[2] , ≤200℃ Note 1:Before level flange sealing device selection, the selection of the EJCLT differential pressure transmitter should
  • 44. EJC Differential Pressure Level Transmitter General Specifications www.bcstgroup.com 38 BCST Group Co.,Ltd be completed, and selected L option in line 60 of the in EJCLT options table; Note 2:The PTFE membrane(F4 membrane) posted on the diaphragm, it could be applied to the measurement of negative pressure, but it applies only to the flat level flange. Order example: For example:EJCLT-AC2A1LNN111N1C [3] , LT-H1FSN [A]:Reference Accuracy:±0.05% [C]:Span:0-400Pa~40kPa(0-40~4000 mmH2O) [2]:Static pressure sensor:10MPa [A]:316L stainless steel diaphragm, Silicone oil fill fluid [1]:Working pressure:16MPa [L]:Level [N]:Perbunan(NBR)process connector gasket [N]:None [1]:With 304 stainless steel mounting bracket [1]:With stainless steel oval-shaped flange with 1/2 NPT female thread [1]:With LCD display [N]:None of explosion protected type [1]:Position number marked on the nameplate [C]:Chinese manual [LT-]: Level flange sealing, no capillary ,⊕ Side [H]:DN80 DIN 2501,E DN2526, 316L stainless steel [1]:Working pressure PN 1MPa/4MPa DIN 2501 [F]:Flange sealing type is flat sealing [S]:Fill fluid is silicone oil [N]:Wetted flange diaphragm surface without special treatment Note3:Differential pressure transmitter options see the EJCLT Series transmitter General Specifications; Note4:The minimum measuring range of the differential pressure Level transmitter should be the larger value of the minimum range of table 1 and table 2. The adjusted span must not be lower than the minimum range. Note5: When measuring pressure or static pressure <50kPa (absolute pressure), it requires special handling during the manufacturing process to ensure that performance.
  • 45. EJCRH/RL Remote seal differential pressure transmitter General Specifications www.bcstgroup.com 39 BCST Group Co.,Ltd EJCRH/RL Remote Seal Differential Pressure Transmitter 1 Application The remote seal differential pressure transmitter EJCDP is suitable to measure liquid, gas, or steam flow as well as liquid level, density and pressure. EJCDP outputs a 4~20mADC signal corresponding to the measured differential pressure. Its highly accurate and stable sensor can also measure the static pressure which can be shown on the integral indicator or remotely monitored via HART communications. Other key features include quick response, remote set-up using communications, self-diagnostics and optional status output for pressure high/low alarm. The range Limits is 0—1kPa~2MPa, The flange’s working pressure are 1.6/4MPa,6.4MPa,10MPa,150psi,300psi or 600psi. 2 Operation Theory and Structure EJCDP remote seal differential pressure transmitter is composed of EJCDP series differential pressure transmitter and the welding installation remote seal flange. The operation theory is the same as EJCDP series differential pressure transmitter (see EJCDP series differential pressure transmitter general specifications), Only the pressure transmission path is different. The pressure loaded in the high or low side, pass from the isolation diaphragm and silicone oil in the flange to the sensor. 3 Input Measured value: Differential pressure, Level Measuring range Lower range value: -100% to +100% of the URL(continuously adjustable) Upper range value: Up to 100% of the URL(continuously adjustable) Spans Table1: Span code, measuring range and SWP Span code Measuring range SWP(Max) Min Max B 1kPa 6kPa The flange’s working pressure C 4kPa 40kPa D 25kPa 250kPa F 200kPa 3MPa Table 2: Flange and minimum measuring range The minimum measuring range of the remote seal differential pressure transmitter should be the larger value of the minimum range of table 1 and table 2.The adjusted span must not be lower than the minimum range. 4 Output Output signal Two wire 4~20mADC output with digital communications, linear or square root programmable. Flange Nominal diameter The minimum measuring range one flange two flange Flat sealing DN 50/2” 10kPa 10kPa DN 80/3” 6kPa 2kPa DN 4” 6kPa 2kPa Bulge sealing DN 50/2” 16kPa 16kPa DN 80/3” 6kPa 2kPa DN 4” 6kPa 2kPa
  • 46. EJCRH/RL Remote seal differential pressure transmitter General Specifications www.bcstgroup.com 40 BCST Group Co.,Ltd HART FSK protocol are superimposed on the 4~20 mADC signal. Output range: 3.9 mA to 20.5 mA. Failure Alarm (the mode can be selected) Low Mode (min): 3.7 mA, High Mode (max): 21 mA No Mode (hold): Keep the effective value before the fault. Note: The standard setting of failure alarm is High Mode. 5 Response Time The amplifier damping constant is 0.1 sec; The sensor and flange’s damping constant is 0.2~3 sec, it depends on the range and range compression ratio. Amplifier damping time constant is adjustable from 0.1 to 60 sec by software and added to response time. 6 General conditions 6.1 Installation conditions The transmitter can be directly flanged in any position. Preferably in such a position that the process flange axes are vertical. Deviations from this can cause a shift in the zero, which can be corrected. The electronic housing can be rotated through 360°and can be fixed in any position. A stop prevents the housing being turned too far. The minimum bend radius of the capillary of 75mm, is strictly prohibited winding! 6.2 Ambient conditions Ambient temperature Min:depends on the fill fluid Max:85℃ -20~65℃,with LCD-indicator Storage temperature/transport temperature Min:depends on the fill fluid Max:85℃ Humidity:0~100% Shock resistant: Acceleration:50g,Duration:11ms Vibration resistance: 500Hz on 2g Electromagnetic Compatibility (EMC) See the EMC Performance Table 4 6.3 Process conditions Temperature limits:-30~400℃ Table 3: Fill fluid, temperature limits and the working pressure range Note : Beyond the above working temperature and working pressure range should be pointed out, a specially designed can be met the requirements. Pressure limits: From 3.5kPa abs. to working pressure. Proof pressure up to 1.5-times the nominal pressure simultaneously on both sides of the transmitter admissible. Flange working pressure ANSI:150psi~600psi DIN: PN 1.6MPa~PN 10MPa One-sided overload: One-sided overload up to the rated pressure. Possibly occurring zero offsets can be corrected. Weight One flange remote seal: DN 50/2”about 7~10kg;DN 80/3” about 8~11kg;DN 4” about 9~12kg; Two flange remote seal: DN 50/2”about 10~16.5kg; Fill fluid Silicone oil (S) High temp. silicone oil (H) Super high temp. silicone oil (U) Vegetable oil (V) Density 25℃ 960 kg/m3 980 kg/m3 1020 kg/m3 937 kg/m3 Temp. limits -40~ 200℃ -10~ 350℃ -10~ 400℃ 0~ 250℃ Temp. Working pressure range (kPa abs.) 20℃ >10 >10 >10 >25 100℃ >25 >25 >25 >50 150℃ >50 >50 >50 >75 200℃ >75 >75 >75 >100 250℃ >100 >100 >100 350℃ >100 >100 400℃ >100
  • 47. EJCRH/RL Remote seal differential pressure transmitter General Specifications www.bcstgroup.com 41 BCST Group Co.,Ltd DN 80/3” about 12~18kg;DN 4” about 14~21kg. Explosion Protected Type NEPSI / ATEX: Ex dⅡC T6 NEPSI / ATEX: Ex iaⅡC T4 Amb. Temp.: -40℃~65℃ 6.4 Supply & Load Requirements 24VDC supply, R≤(Us-12V)/Imax kΩ, Imax=23 mA. Maximum voltage limited: 42VDC, Minimum voltage limited: 12VDC, 15VDC(with LCD display) 230Ω to 600Ω for digital communication Wetted Parts Materials Flange: 316 stainless steel Isolating Diaphragm:316L stainless steel / Hastelloy C/FEP or PFA plated on 316L/Tantalum Nuts and Bolts: 304 stainless steel Process Connector: 316 stainless steel Fill fluid: Silicone oil/ Vegetable oil Process Connector Gasket:Perbunan(NBR)/Viton (FKM)/Teflon(PTFE) Amplifier Housing: Aluminum with epoxy resin coat Housing Gasket: Perbunan(NBR) Name plate and tag:304 stainless steel Degrees of Protection: IP67 Electrical Connection The electrical connection is made via cable entry M20x1.5.The screw terminals are suitable for wire cross-sections up to 2.5mm2 . Process Connection Flange with fixing thread 7/16-20 UNF .The flange comply with the ANSI standard or DIN standards. ———————————————————————————————————————————— Table 4 : EMC Performance Table Items Test items Basic standards Test conditions Performance Level 1 Radiated interference (Housing) GB/T 9254-2008 30MHz~1000MHz OK 2 Conducted interference(DC power port) GB/T 9254-2008 0.15MHz~30MHz OK 3 Electrostatic Discharge (ESD) Immunity GB/T 17626.2-2006 4kV(Line) 8kV(Air) B 4 RF electromagnetic field immunity GB/T 17626.3-2006 10V/m (80MHz~1GHz) A 5 Frequency magnetic field immunity GB/T 17626.8-2006 30A/m A 6 Electrical Fast Transient Burst Immunity GB/T 17626.4-2008 2kV(5/50ns,5kHz) B 7 Surge Immunity GB/T 17626.5-2008 0.5kV(line to line) 1kV(line to ground) (1.2us/50us) B 8 Conducted interference immunity induced by RF field GB/T 17626.6-2008 3V (150KHz~80MHz) A Note:(1)Performance level A description: The technical specifications within the limits of normal performance.
  • 48. EJCRH/RL Remote seal differential pressure transmitter General Specifications www.bcstgroup.com 42 BCST Group Co.,Ltd (2)Performance level B description: Temporary reduction or loss of functionality or performance, it can restore itself. The actual operating conditions, storage, and data will not be changed.
  • 49. EJCRH/RL Remote seal differential pressure transmitter General Specifications www.bcstgroup.com 43 BCST Group Co.,Ltd 7 DIMENSIONS Unit : mm Figure 1 Two side flange remote seal device Figure 2 One side flange remote seal device Note:(1)The one side flange can be installed in the high or low pressure side of the transmitter ; (2)The one or two side flange remote seal transmitter’s installation is the same way as the EJCDPseries differential pressure transmitter
  • 50. EJCRH/RL Remote seal differential pressure transmitter General Specifications www.bcstgroup.com 44 BCST Group Co.,Ltd Table 5: Remote seal flange dimensions Nominal diameter Working pressure ΦD ΦK Φd1 Φd2 Φd3 t b Bolt Bulge seal Flat seal DN 50 PN1.6/4MPa 165 125 48.3 57 102 3+0.5 20 4 M16 (Sealing DIN 2526E) PN 6.4MPa 18 135 48.3 57 102 3+0.5 26 4 M20 (Flange DIN 2501) PN 10MPa 195 145 48.3 57 102 3+0.5 28 4 M20 DN 80 PN1.6/4MPa 200 160 76 75 138 3+0.5 24 8 M16 (Sealing DIN 2526E) PN 6.4MPa 215 170 76 75 138 3+0.5 28 8 M20 (Flange DIN 2501) PN 10MPa 230 180 76 75 138 3+0.5 32 8 M24 DN 2" (ANSI B 16.5 RF) 150psi 152.4 120.6 48.3 57 92.1 3+0.5 17.4 4 M18 300psi 165.1 127.0 48.3 57 92.1 3+0.5 20.6 8 M18 600psi 165.1 127.0 48.3 57 92.1 6.35 31.75 8 M18 DN 3" (ANSI B 16.5 RF) 150psi 190.5 152.4 76 75 127 3+0.5 22.2 4 M16 300psi 209.5 168.3 76 75 127 3+0.5 27.0 8 M20 600psi 209.5 168.3 76 75 127 6.35 38.05 8 M20 DN 4“ 150psi 229 191 89 89 157 3+0.5 30 8 M18 (ANSI B 16.5 RF) 300psi 255 200 89 89 157 3+0.5 32 8 M18 Figure 3 Two side flange remote seal of threaded mount device
  • 51. EJCRH/RL Remote seal differential pressure transmitter General Specifications www.bcstgroup.com 45 BCST Group Co.,Ltd Figure 4 One side flange remote seal of threaded mount device Note:(1)The one side flange can be installed in the high or low pressure side of the transmitter ; (2)The one or two side flange remote seal transmitter’s installation is the same way as the EJCDPseries differential pressure transmitter. 8 Terminal Configuration Note:Quick interface functionally equivalent to the signal terminal 9 Process Connections Description of the no flange side
  • 52. EJCRH/RL Remote seal differential pressure transmitter General Specifications www.bcstgroup.com 46 BCST Group Co.,Ltd 10 Model and suffix codes[1] 1 Flange sealing device selection of the remote seal differential pressure transmitter RP1001 10 Flange sealing device RH- With capillary ⊕side RL- With capillary Θside 20 Process connection, Flange and diaphragm material A DN50 DIN 2501 E DN2526 316L stainless steel B DN50 DIN 2501 E DN2526 Hastelloy C C DN50 DIN 2501 E DN2526 Tantalum H DN80 DIN 2501 E DN2526 316L stainless steel I DN80 DIN 2501 E DN2526 Hastelloy C G DN80 DIN 2501 E DN2526 Tantalum D DN2″ANSI B 16.5 RF ANSI B 16.5 316L stainless steel E DN2″ANSI B 16.5 RF ANSI B 16.5 Hastelloy C F DN2″ANSI B 16.5 RF ANSI B 16.5 Tantalum K DN3″ANSI B 16.5 RF ANSI B 16.5 316L stainless steel L DN3″ANSI B 16.5 RF ANSI B 16.5 Hastelloy C M DN3″ANSI B 16.5 RF ANSI B 16.5 Tantalum N DN4″ANSI B 16.5 RF ANSI B 16.5 316L stainless steel O DN4″ANSI B 16.5 RF ANSI B 16.5 Hastelloy C P DN4″ANSI B 16.5 RF ANSI B 16.5 Tantalum 30 Working pressure 1 PN 1MPa/4MPa DIN 2501 2 PN 6.4MPa DIN 2501 3 PN 10MPa DIN 2501 6 150psi ANSI B 16.5 7 300psi ANSI B 16.5 8 600psi ANSI B 16.5(not including DN4″ANSI B 16.5) 40 Process connections F Flat sealing H Bulge sealing,316L stainless steel,extended diaphragm seal 50mm I Bulge sealing,316L stainless steel,extended diaphragm seal 100mm G Bulge sealing,316L stainless steel,extended diaphragm seal 150mm L Bulge sealing,Hastelloy C, extended diaphragm seal 50mm M Bulge sealing,Hastelloy C, extended diaphragm seal 100mm N Bulge sealing,Hastelloy C, extended diaphragm seal 150mm 50 Fill fluid S Silicone oil -40~200℃ H High temp. silicone oil -10~350℃ U Super high temp. silicone oil -10~400℃ V Vegetable oil 0~250℃ 60 Capillary Length 1 1m 2 2m
  • 53. EJCRH/RL Remote seal differential pressure transmitter General Specifications www.bcstgroup.com 47 BCST Group Co.,Ltd 3 3m 4 4m 5 5m 6 6m 8 8m A 10m S Special length 70 Capillary component characteristics N P None With PVC protective coating capillary 80 Diaphragm Protection N None 1 FEP plated on 316L, ≤180℃ 2 PFA plated on 316L, ≤260℃ 3 PTFE coated on 316L[2] , ≤200℃ Note 1: Before flange sealing device selection, the selection of the EJCDPdifferential pressure transmitter should be completed, and selected R option in line 60 of the in EJCDPoptions table; Note 2: The PTFE membrane(F4 membrane) posted on the diaphragm, it could be applied to the measurement of negative pressure >50kPa, but it applies only to the flat level flange. ———————————————————————————————————————————————————— Order example: For example: EJCDP-AC2A1LNN111N1C[3] , RH-H1FS4PN, RL-H1FS4PN. [A]:Reference Accuracy:±0.05% [C]:Span:0-400Pa~40kPa(0-40~4000 mmH2O) [2]:Static pressure sensor:10MPa [A]:316L stainless steel diaphragm, Silicone oil fill fluid [1]:Working pressure:16MPa [L]:Level [N]:Perbunan(NBR)process connector gasket [N]:None [1]:With 304 stainless steel mounting bracket [1]:With stainless steel oval-shaped flange with 1/2 NPT female thread [1]:With LCD display [N]:None of explosion protected type [1]:Position number marked on the nameplate [C]:Chinese manual [RH-]:Flange sealing device of high side [H]: DN80(DIN 2501),E DN2526, 316L stainless steel diaphragm [1]: Working pressure PN 1MPa/4MPa(DIN 2501) [F]: Flange sealing type is flat sealing [S]:[S]: Fill fluid is silicone oil [4]: Capillary’s length is 4m [P]: With PVC protective coating capillary [N]: Diaphragm surface without special treatment [RL-]:Flange sealing device of low side [H]: DN80 (DIN 2501) ,E DN2526, 316L stainless steel diaphragm [1]: Working pressure PN 1MPa/4MPa(DIN 2501) [F]: Flange sealing type is flat sealing [S]:Fill fluid is silicone oil [4]: Capillary’s length is 4m [P]: With PVC protective coating capillary [N]:Diaphragm surface without special treatment Note 3:Differential pressure transmitter options see the EJCDP Series transmitter general specifications; Note 4:The minimum measuring range of the remote seal differential pressure transmitter should be the larger value of the minimum range of table 1 and table 2. The adjusted span must not be lower than the minimum range. Note 5:When measuring pressure or static pressure <50kPa (absolute pressure), it requires special handling during the manufacturing process to ensure that performance.
  • 54. EJCRH/RL Remote seal differential pressure transmitter General Specifications www.bcstgroup.com 48 BCST Group Co.,Ltd 2 Threaded mount device remote seal of differential pressure transmitter EJCDP[6] 10 Flange sealing device TH- With capillary ⊕side TL- With capillary Θside 20 Diaphragm material U 316L stainless steel V Hastelloy C W Tantalum 30 Flushing spare hole 1 None 0 Yes 40 Fill fluid S Silicone oil -40~200℃ H High temp. silicone oil -10~350℃ U Super high temp. silicone oil -10~400℃ V Vegetable oil 0~250℃ 50 Capillary Length 1 1m 2 2m 3 3m 4 4m 5 5m 6 6m 8 8m S Special length 60 Capillary component characteristics N None P With PVC protective coating capillary Note 6: Before flange sealing device selection, the selection of the EJCDPdifferential pressure transmitter should be completed, and selected S option in line 60 of the in EJCDPoptions table; ———————————————————————————————————————————————————— For example: EJCDP-AC2A1LNN111N1C[7] , TH-U1S3N [A]:Reference Accuracy:±0.05% [C]:Span:0-400Pa~40kPa(0-40~4000 mmH2O) [2]:Static pressure sensor:10MPa [A]:316L stainless steel diaphragm, Silicone oil fill fluid [1]:Working pressure:16MPa [L]:Level [N]:Perbunan(NBR)process connector gasket [N]:None [1]:With 304 stainless steel mounting bracket [1]:With stainless steel oval-shaped flange with 1/2 NPT female thread [1]:With LCD display [N]:None of explosion protected type [1]:Position number marked on the nameplate [C]:Chinese manual [TH-] High side is threaded mount device remote seal [U]:316L stainless steel diaphragm [1]:No relief valves [S]:Silicone oil fill fluid [3]:Capillary’s length is 3m [P]:With PVC protective coating capillary Note 7: Content with note 3 Note 8: Content with note 4 Note 9: Content with note 5
  • 55. EJCRN/S Remote Seal Gauge/Absolute Pressure Transmitter General Specifications www.bcstgroup.com 48 BCST Group Co.,Ltd EJCRN Remote Seal Gauge Pressure Transmitter EJCRS Remote Seal Absolute Pressure Transmitter 1 Application The remote seal gauge/absolute pressure transmitter EJCRN/S is suitable to measure liquid, gas, or steam flow as well as liquid level, density and pressure. RP1001 outputs a 4~20mADC signal corresponding to the measured gauge/absolute pressure. Other key features include quick response, remote set-up using communications, self-diagnostics and optional status output for pressure high/low alarm. The range Limits is 0—6kPa~25MPa, The flange’s working pressure are 1.6/4MPa,6.4MPa,10MPa,150psi,300psi or 600psi. 2 Operation Theory and Structure EJCRN/S remote seal gauge/absolute pressure transmitter is composed of EJCRN/S series gauge/absolute pressure transmitter and the welding installation remote seal flange. The operation theory is the same as EJCRN/S series gauge/absolute pressure transmitter (see EJCRN/S series gauge/absolute pressure transmitter general specifications), Only the pressure transmission path is different. The pressure loaded in the high or low side, pass from the isolation diaphragm and silicone oil in the flange to the sensor. 3 Input Measured value: Gauge/absolute pressure, Level Measuring range Gauge pressure: -100%URL to +100%URL (continuously adjustable) Absolute pressure: 0 to +100%URL(continuously adjustable) Spans Tanble1Span code, measuring range and SWP Span code Measuring range SWP(Max) Min C 6kPa 40kPa The flange’s working pressure D 25kPa 250kPa F 30kPa 3MPa G 1MPa 10MPa H 2.1MPa 21MPa I 4MPa 40MPa L 6kPa abs. 40kPa abs. M 25kPa abs. 250kPa abs. O 30kPa abs. 3MPa abs. Table 2: Flange and minimum measuring range The minimum measuring range of the remote seal Flange Nominal diameter The min/max measuring range The max length of capillary Flat sealing DN 25/1” 10kPa/25MPa 10m DN 50/2” 10kPa/10MPa 12m DN 80/3” 6kPa/10MPa 16m DN 4” 6kPa/3MPa 16m Bulge sealing DN 50/2” 16kPa/10MPa 10m DN 80/3” 6kPa/10MPa 16m DN 4” 6kPa/3MPa 16m threaded mount sealing ¢109mm 16kPa/25MPa 10m
  • 56. EJCRN/S Remote Seal Gauge/Absolute Pressure Transmitter General Specifications www.bcstgroup.com 49 BCST Group Co.,Ltd gauge/absolute pressure transmitter should be the larger value of the minimum range of table 1 and table 2.The adjusted span must not be lower than the minimum range. 4 Output Output signal Two wire 4~20mADC output with digital communications, linear or square root programmable. HART FSK protocol are superimposed on the 4~20 mADC signal. Output range: 3.9 mA to 20.5 mA. Failure Alarm (the mode can be selected) Low Mode (min): 3.7 mA, High Mode (max): 21 mA No Mode (hold): Keep the effective value before the fault. Note: The standard setting of failure alarm is High Mode. 5 Response Time The amplifier damping constant is 0.1 sec; The sensor and flange’s damping constant is 0.2~3 sec, it depends on the range and range compression ratio. Amplifier damping time constant is adjustable from 0.1 to 60 sec by software and added to response time. 6 General conditions 6.1 Installation conditions The transmitter can be directly flanged in any position. Preferably in such a position that the process flange axes are vertical. Deviations from this can cause a shift in the zero, which can be corrected. The electronic housing can be rotated through 360°and can be fixed in any position. A stop prevents the housing being turned too far. The minimum bend radius of the capillary of 75mm, is strictly prohibited winding! 6.2 Ambient conditions Ambient temperature Min:depends on the fill fluid Max:85℃ -20~65℃,with LCD-indicator Storage temperature/transport temperature Min:depends on the fill fluid Max:85℃ Humidity:0~100% Shock resistant: Acceleration:50g,Duration:11ms Vibration resistance: 500Hz on 2g Electromagnetic Compatibility (EMC) See the EMC Performance Table 4 6.3 Process conditions Temperature limits:-30~400℃ Table 3: Fill fluid, temperature limits and the working pressure range Note : Beyond the above working temperature and working pressure range should be pointed out, a specially designed can be met the requirements. Pressure limits: From vacuum to working pressure. Flange working pressure ANSI:150psi~600psi DIN: PN 1.6MPa~PN 10MPa Weight Fill fluid Silicone oil (S) High temp. silicone oil (H) Super high temp. silicone oil (U) Vegetable oil (V) Density 25℃ 960 kg/m3 980 kg/m3 1020 kg/m3 937 kg/m3 Temp. limits -40~ 200℃ -10~ 350℃ -10~ 400℃ 0~ 250℃ Temp. Working pressure range (kPa abs.) 20℃ >10 >10 >10 >25 100℃ >25 >25 >25 >50 150℃ >50 >50 >50 >75 200℃ >75 >75 >75 >100 250℃ >100 >100 >100 350℃ >100 >100 400℃ >100
  • 57. EJCRN/S Remote Seal Gauge/Absolute Pressure Transmitter General Specifications www.bcstgroup.com 50 BCST Group Co.,Ltd DN 50/2”about 7~10kg;DN 80/3” about 8~11kg;DN 4” about 9~12kg; Explosion Protected Type NEPSI / ATEX: Ex dⅡC T6 NEPSI / ATEX: Ex iaⅡC T4 Amb. Temp.: -40℃~65℃ 6.4 Supply & Load Requirements 24VDC supply, R≤(Us-12V)/Imax kΩ, Imax=23 mA. Maximum voltage limited: 42VDC, Minimum voltage limited: 12VDC, 15VDC(with LCD display) 230Ω to 600Ω for digital communication Wetted Parts Materials Flange: 316 stainless steel Isolating Diaphragm:316L stainless steel / Hastelloy C/FEP or PFA plated on 316L/Tantalum Nuts and Bolts: 304 stainless steel Process Connector: 316 stainless steel Fill fluid: Silicone oil/ Vegetable oil Process Connector Gasket:Perbunan(NBR)/Viton (FKM)/Teflon(PTFE) Amplifier Housing: Aluminum with epoxy resin coat Housing Gasket: Perbunan(NBR) Name plate and tag:304 stainless steel Degrees of Protection: IP67 Electrical Connection The electrical connection is made via cable entry M20x1.5.The screw terminals are suitable for wire cross-sections up to 2.5mm2 . Process Connection The flange comply with the ANSI standard or DIN standards. ———————————————————————————————————————————— Table 4 : EMC Performance Table Items Test items Basic standards Test conditions Performance Level 1 Radiated interference (Housing) GB/T 9254-2008 30MHz~1000MHz OK 2 Conducted interference(DC power port) GB/T 9254-2008 0.15MHz~30MHz OK 3 Electrostatic Discharge (ESD) Immunity GB/T 17626.2-2006 4kV(Line) 8kV(Air) B 4 RF electromagnetic field immunity GB/T 17626.3-2006 10V/m (80MHz~1GHz) A 5 Frequency magnetic field immunity GB/T 17626.8-2006 30A/m A 6 Electrical Fast Transient Burst Immunity GB/T 17626.4-2008 2kV(5/50ns,5kHz) B 7 Surge Immunity GB/T 17626.5-2008 0.5kV(line to line) 1kV(line to ground) (1.2us/50us) B 8 Conducted interference immunity induced by RF field GB/T 17626.6-2008 3V (150KHz~80MHz) A Note:(1)Performance level A description: The technical specifications within the limits of normal performance. (2)Performance level B description: Temporary reduction or loss of functionality or performance, it can restore itself. The actual operating conditions, storage, and data will not be changed.
  • 58. EJCRN/S Remote Seal Gauge/Absolute Pressure Transmitter General Specifications www.bcstgroup.com 51 BCST Group Co.,Ltd 7 DIMENSIONS Unit : mm Figure 1 Gauge/Absolute remote seal device (RS Type) Figure 2 Gauge/Absolute remote seal device without capillary (RN Type)
  • 59. EJCRN/S Remote Seal Gauge/Absolute Pressure Transmitter General Specifications www.bcstgroup.com 52 BCST Group Co.,Ltd Table 5: Remote seal flange dimensions Nominal diameter Working pressure ΦD ΦK Φd1 Φd2 Φd3 t b Bolt Bulge seal Flat seal DN 50 PN1.6/4MPa 165 125 48.3 57 102 3+0.5 20 4 M16 (Sealing DIN 2526E) PN 6.4MPa 18 135 48.3 57 102 3+0.5 26 4 M20 (Flange DIN 2501) PN 10MPa 195 145 48.3 57 102 3+0.5 28 4 M20 DN 80 PN1.6/4MPa 200 160 76 75 138 3+0.5 24 8 M16 (Sealing DIN 2526E) PN 6.4MPa 215 170 76 75 138 3+0.5 28 8 M20 (Flange DIN 2501) PN 10MPa 230 180 76 75 138 3+0.5 32 8 M24 DN 2" (ANSI B 16.5 RF) 150psi 152.4 120.6 48.3 57 92.1 3+0.5 17.4 4 M18 300psi 165.1 127.0 48.3 57 92.1 3+0.5 20.6 8 M18 600psi 165.1 127.0 48.3 57 92.1 6.35 31.75 8 M18 DN 3" (ANSI B 16.5 RF) 150psi 190.5 152.4 76 75 127 3+0.5 22.2 4 M16 300psi 209.5 168.3 76 75 127 3+0.5 27.0 8 M20 600psi 209.5 168.3 76 75 127 6.35 38.05 8 M20 DN 4“ 150psi 229 191 89 89 157 3+0.5 30 8 M18 (ANSI B 16.5 RF) 300psi 255 200 89 89 157 3+0.5 32 8 M18 Figure 3 Internal diaphragm remote seal (US Type)
  • 60. EJCRN/S Remote Seal Gauge/Absolute Pressure Transmitter General Specifications www.bcstgroup.com 53 BCST Group Co.,Ltd Figure 4 Internal diaphragm remote seal without capillary (UN Type) Table 6 Internal diaphragm remote seal flange dimensions (DIN 2501) DN PN Dimensions, mm Weight kg D K d4 b f H d2 G2 25 1MPa/4MPa 115 85 68 22 2 - 14 - 1.5 25 6.3MPa/10MPa 140 100 68 24 2 52 - 4×M16 3.2 16MPa 140 100 68 24 2 52 - 4×M16 3.6 25MPa 150 105 68 28 2 96 - 4×M20 4 Table 7 Internal diaphragm remote seal flange dimensions (ANSI B 16.5) DN psi Dimensions, mm Weight kg D K d2 d4 b f H G2UNC 1" 150 110 79.5 16 51 22 2 - - 1.4 300 125 89 20 51 22 2 - - 1.7 1" 600 125 89 - 51 25 7 53 4×5/8” 3.6 1500 150 101.5 - 51 36 7 64 4×7/8” 4.0
  • 61. EJCRN/S Remote Seal Gauge/Absolute Pressure Transmitter General Specifications www.bcstgroup.com 54 BCST Group Co.,Ltd Figure 5 Remote seal of threaded mount device (TS Type) 8 Terminal Configuration Figure 6 Electrical connection diagram Note:Quick interface functionally equivalent to the signal terminal
  • 62. EJCRN/S Remote Seal Gauge/Absolute Pressure Transmitter General Specifications www.bcstgroup.com 55 BCST Group Co.,Ltd 9 Model and suffix codes[1] 1 Flange sealing device selection of the remote seal gauge/absolute pressure transmitter EJCRN/S 10 Flange sealing device RN- Without capillary RS- With capillary 20 Process connection, Flange and diaphragm material A DN50 DIN 2501 E DN2526 316L stainless steel B DN50 DIN 2501 E DN2526 Hastelloy C C DN50 DIN 2501 E DN2526 Tantalum H DN80 DIN 2501 E DN2526 316L stainless steel I DN80 DIN 2501 E DN2526 Hastelloy C G DN80 DIN 2501 E DN2526 Tantalum D DN2″ANSI B 16.5 RF ANSI B 16.5 316L stainless steel E DN2″ANSI B 16.5 RF ANSI B 16.5 Hastelloy C F DN2″ANSI B 16.5 RF ANSI B 16.5 Tantalum K DN3″ANSI B 16.5 RF ANSI B 16.5 316L stainless steel L DN3″ANSI B 16.5 RF ANSI B 16.5 Hastelloy C M DN3″ANSI B 16.5 RF ANSI B 16.5 Tantalum N DN4″ANSI B 16.5 RF ANSI B 16.5 316L stainless steel O DN4″ANSI B 16.5 RF ANSI B 16.5 Hastelloy C P DN4″ANSI B 16.5 RF ANSI B 16.5 Tantalum 30 Working pressure 1 PN 1MPa/4MPa DIN 2501 2 PN 6.4MPa DIN 2501 3 PN 10MPa DIN 2501 6 150psi ANSI B 16.5 7 300psi ANSI B 16.5 8 600psi ANSI B 16.5(not including DN4″ANSI B 16.5) 40 连接形式 F Flat sealing H Bulge sealing,316L stainless steel,extended diaphragm seal 50mm I Bulge sealing,316L stainless steel,extended diaphragm seal 100mm G Bulge sealing,316L stainless steel,extended diaphragm seal 150mm L Bulge sealing,Hastelloy C, extended diaphragm seal 50mm M Bulge sealing,Hastelloy C, extended diaphragm seal 100mm N Bulge sealing,Hastelloy C, extended diaphragm seal 150mm 50 Fill fluid S Silicone oil -40~200℃ H High temp. silicone oil -10~350℃ U Super high temp. silicone oil -10~400℃ V Vegetable oil 0~250℃ 60 Capillary Length 1 1m 2 2m
  • 63. EJCRN/S Remote Seal Gauge/Absolute Pressure Transmitter General Specifications www.bcstgroup.com 56 BCST Group Co.,Ltd 3 3m 4 4m 5 5m 6 6m 8 8m A 10m S Special length 70 Capillary component characteristics N P None With PVC protective coating capillary 80 Diaphragm Protection N None 1 FEP plated on 316L, ≤180℃ 2 PFA plated on 316L, ≤260℃ 3 PTFE coated on 316L[2] , ≤200℃ Note 1: Before flange sealing device selection, the selection of the EJCRN/S gauge/absolute pressure transmitter should be completed, and selected R option in line 40 of the in EJCRN/S options table; Note 2: The PTFE membrane(F4 membrane) posted on the diaphragm, it could be applied to the measurement of negative pressure >50kPa, but it applies only to the flat level flange. ———————————————————————————————————————————————————— Order example: For example: EJCBP-ACARNN1N1C[3], RN-H1FS0PN。 [A]:Reference Accuracy:±0.05% [C]:Span:0-400Pa~40kPa(0-40~4000 mmH2O) [A]:316L stainless steel diaphragm, Silicone oil fill fluid [R]:Remote seak [N]:None [N]:None [1]:With LCD display [N]:None of explosion protected type [1]:Position number marked on the nameplate [C]:Chinese manual [RN-]:Flange sealing device without capillary [H]:DN80(DIN 2501),E DN2526, 316L stainless steel diaphragm [1]: Working pressure PN 1MPa/4MPa(DIN 2501) [F]: Flange sealing type is flat sealing [S]: Fill fluid is silicone oil [4]: Capillary’s length is 4m [P]: With PVC protective coating capillary [N]: Diaphragm surface without special treatment Note 3:Gauge/absolute pressure transmitter options see the EJCRN/S Series transmitter general Specifications; Note 4:The minimum measuring range of the remote seal gauge/absolute pressure transmitter should be the larger value of the minimum range of table 1 and table 2. The adjusted span must not be lower than the minimum range. Note 5:When measuring pressure <50kPa (absolute pressure), it requires special handling during the manufacturing process to ensure that performance.
  • 64. EJCRN/S Remote Seal Gauge/Absolute Pressure Transmitter General Specifications www.bcstgroup.com 57 BCST Group Co.,Ltd 2 Selection of the Internal diaphragm remote seal gauge/absolute pressure transmitter EJCRN/S [6] 10 Flange sealing device UN- Without capillary US- With capillary 20 Process connection, Flange and diaphragm material A DN25 DIN 2501 D DN2526 PN 1MPa/4MPa B DN25 DIN 2501 D DN2526 PN 6.3MPa/10MPa C DN25 DIN 2501 D DN2526 PN 16MPa D DN25 DIN 2501 D DN2526 PN 25MPa E DN1″ANSI B 16.5 RF ANSI B 16.5 150psi F DN1″ANSI B 16.5 RF ANSI B 16.5 300psi G DN1″ANSI B 16.5 RF ANSI B 16.5 600psi H DN1″ANSI B 16.5 RF ANSI B 16.5 1500psi 30 Fill fluid S Silicone oil -40~200℃ H High temp. silicone oil -10~350℃ V Vegetable oil 0~250℃ 40 Capillary Length 1 1m 2 2m 3 3m 4 4m 5 5m 6 6m S Special length 50 Capillary component characteristics N P None With PVC protective coating capillary Note 6: Before flange sealing device selection, the selection of the EJCRN/S gauge/absolute pressure transmitter should be completed, and selected R option in line 40 of the in EJCRN/S options table. ———————————————————————————————————————————————————— Order example: For example: EJCBP-ACARNN1N1C[3] , UN-AS [A]:Reference Accuracy:±0.05% [C]:Span:0-400Pa~40kPa(0-40~4000 mmH2O) [A]:316L stainless steel diaphragm, Silicone oil fill fluid [R]:Remote seak [N]:None [N]:None [1]:With LCD display [N]:None of explosion protected type [1]:Position number marked on the nameplate [C]:Chinese manual [UN-]: Internal diaphragm remote seal, without capillary [A]:DN25(DIN 2501) ,D DN2526, Working pressure PN 1MPa/4MPa [S]:Fill fluid is silicone oil Note 7:Content with note 3 Note 8:Content with note 4 Note 9:Content with note 5