SlideShare una empresa de Scribd logo
1 de 7
Descargar para leer sin conexión
Shigeru Aoki, Katsumi Kurita / International Journal of Engineering Research and
Applications (IJERA) ISSN: 2248-9622 www.ijera.com
Vol. 3, Issue 4, Jul-Aug 2013, pp.2182-2188
2182 | P a g e
Effect Of Magnet And Oil Damper On Reduction Of Seismic
Response Of Houses
Shigeru Aoki*, Katsumi Kurita*
*Department of Mechanical Engineering, Tokyo Metropolitan College of Industrial Technology, Japan
ABSTRACT
It is important to reduce the seismic
response of houses in order to prevent from
collapse of houses. Some control methods for
seismic response of houses are developed. The oil
dampers using the flow resistance of the silicon oil
have been developed. In this paper, a Magnet Oil
Damper (MOD) in which permanent magnets are
added to the oil damper is proposed in order to
improve the performance of the oil damper. MOD
is installed in two-story house. The effect of MOD
is examined experimentally. The peaks of
resonance curves are reduced when MOD is used.
The effectiveness of MOD is examined by
numerical simulation using the analytical model.
The response of the house subjected to actual
earthquake excitation decreases when MOD is
used.
Keywords - Damper, Earthquake resistant, Forced
vibration, Frequency response function, Seismic
motion
I. INTRODUCTION
In recent years, destructive earthquake
disasters have happened in the world. A lot of houses
are collapsed under large earthquakes. It is important
to reduce the seismic response of houses in order to
prevent from collapse of houses. Some reduction
methods for seismic response of houses are
developed, for example, laminated rubber bearings
are used[1]-[3]. Other types of passive dampers are
proposed[4]. Design methods for dynamic vibration
absorbers[5]-[8] and tuned mass dampers[9][10] are
proposed. Some devices utilize nonlinear
characteristics, impact[11], friction[12] and plastic
deformation[13].
For residence, two-story houses are general
in Japan. It is required that construction and
maintenance of the dampers are easy, especially for
the dampers for low rise houses.
The authors have proposed the oil dampers
using the flow resistance of the silicon oil. The oil
dampers are fixed on the foundation and connected to
ceiling of first floor with connecting rod. The oil
dampers are easily installed in the houses even if the
houses have been built up. The effect of the oil
damper on reduction of seismic response is presented
in the previous the papers[14][15].
In this paper, a Magnet Oil Damper (MOD)
in which permanent magnets are added to the oil
damper is proposed in order to improve the
performance of the oil damper. The neodymium
magnets are used inside of the oil damper. The effect
of MOD is examined experimentally. A model of
two-story house is made and MOD is fixed on the
foundation. The model is excited horizontally and the
resonance curves including the first and second
vibration modes are measured. For comparison, a
model without damper, with magnet damper (without
oil), oil damper (without magnet) and MOD are used.
The peaks of the resonance curves are reduced when
the dampers are used. When MOD is used, reduction
rate is largest. The damping ratio is also obtained.
The damping ratio is largest when MOD is used.
Next, the effectiveness of MOD is examined
by numerical simulation. Two-story house with
damper is modeled as a two-degree-of-freedom
system. Seismic responses of the two story house are
obtained using actual earthquake excitations as input.
It is demonstrated that seismic responses are reduced
when MOD is used.
II. EXPERIMENTAL SETUP
Two story houses are focused on and a new
type of damper, MOD, using silicon oil and
permanent magnets is proposed. The effectiveness of
MOD is examined experimentally. An experimental
model of two-story house is made and some types of
dampers are fixed on the foundation and connected to
the model of the ceiling of the first floor with
connecting rod. These types of the dampers are easily
installed in the houses even if the houses have been
built up.
2.1 Design and structure of MOD
A new damper that uses permanent magnets
and the silicon oil is designed. Damper is designed to
move only in one direction so that movement of the
damper is steady.
Figure 1 shows shape and the size of MOD.
Figure 2 shows names of parts in the main portion of
MOD. Figure 3 shows a photograph of parts of
MOD. For a viscous material of the damper, the
silicon oil of kinematic viscosity 30000cst is used.
Two neodymium magnets are installed in the damper
and the inner wall of the pool, respectively, as shown
Fig.2.
Shigeru Aoki, Katsumi Kurita / International Journal of Engineering Research and
Applications (IJERA) ISSN: 2248-9622 www.ijera.com
Vol. 3, Issue 4, Jul-Aug 2013, pp.2182-2188
2183 | P a g e
2.2 Principle of MOD
MOD is fixed on the foundation of the
experimental model of two-story house. As shown in
Fig.1, a connecting rod is installed in the rectangular
solid at one end and connected to the model of the
ceiling of the first floor at the other end. The
connecting point is rolling joint. The self-aligning
ball bearing is used. A fit between the bearing and the
connecting rod is loose fit considering vertical
motion[16]. The connecting rod is shaken around the
bearing as fulcrum as shown in Fig.4. As a result, the
damping force is caused by resistance on the surface
of the rectangular solid and the flow resistance of the
silicon oil in the damper according to the movement
of the rectangular solid. In addition, the magnets are
installed in the rectangular solid and the inner wall
Fig.1 Size and shape of Magnet Oil Damper (mm)
Fig.3 Parts of MOD
Rectangular solid
Main parts
Connecting rod
Connecting point to the
ceiling of the first floor
Shigeru Aoki, Katsumi Kurita / International Journal of Engineering Research and
Applications (IJERA) ISSN: 2248-9622 www.ijera.com
Vol. 3, Issue 4, Jul-Aug 2013, pp.2182-2188
2184 | P a g e
of the pool with same polar and repulse mutually.
These resistances and the repulsion force cause the
damping force which reduces the vibration.
2.3 Structural model of house
Figure 5 shows shape and the size of the
experimental model of two-story house. The size of
foundation is 250×250×25mm. The size of the first
floor part and the second floor part is
250×250×10mm. The size of the pillars is
250×25×3mm. The size of the model is determined
considering the fundamental natural frequency of
ordinary Japanese houses.
2.4 Experimental method
The model of two-story house is set on the
shaking table as shown in Fig.6. MOD is fixed on the
foundation and connected to the model of the ceiling
of the first floor with connecting rod. The model is
shaken in horizontal direction. The acceleration
pickups are fixed by bolt on side of the foundation,
the first floor and the second floor of the model. The
excitation frequency is changed from 1 to 25 Hz, and
the acceleration response amplitude is measured. The
graphs of the acceleration response amplitude ratio of
the first floor, and the second floor to the foundation
are drawn from the outcome of the experiment.
Responses of four conditions (case without damper,
case with magnet damper, case with oil damper and
case with MOD) are measured respectively. The
result of a measurement in each condition is
compared. The excitation amplitude is 1mm at 1Hz.
Fig.7 Amplitude ratio of first floor
2.5 Results of experiment
A comparative example of the acceleration
response amplitude ratio of the first floor (frequency
response function) is shown in Fig.7. Solid line
shows results for the case with MOD and broken line
shows for the case without damper. The peaks of the
first vibration mode and the second vibration mode
decrease when MOD is used.
Table 1 shows peaks of the acceleration
response amplitude ratios and the damping ratios of
the first vibration mode and the second vibration
mode. The damping ratio is obtained by the half
power method. Comparing four conditions, the
acceleration amplitude ratios at the peaks of the first
vibration mode and the second vibration mode are
reduced when the dampers are used. MOD is the
most effective on reduction of the peaks of the first
vibration mode and the second vibration mode.
Shigeru Aoki, Katsumi Kurita / International Journal of Engineering Research and
Applications (IJERA) ISSN: 2248-9622 www.ijera.com
Vol. 3, Issue 4, Jul-Aug 2013, pp.2182-2188
2185 | P a g e
Damping ratio of the system with MOD is about
twice that without damper. Reduction effect of MOD
on the second floor is comparable to the first floor.
Table.1 Amplitude ratio and damping ratio
III. NUMERICAL SIMULATION
The effectiveness of the dampers is
examined by numerical simulation using an
analytical model.
3.1 Analytical model
Two-story house with the damper is
assumed to be modeled as a linear two-degree-of-
freedom system shown in Fig.8. Equations of motion
are given as:
       
    




0
0
12212222
212112121111
xxkxxcxm
xxkyxkxxcyxcxm


(1)
where subscript 1 is for the first floor and 2 is for the
second floor and m is mass, c is the damping
coefficient, k is the spring constant and x is the
absolute displacement of the floor, y is the absolute
displacement of the ground. Frequency transfer
functions are obtained as Eq.(2).











CB
D
sY
sX
CB
A
sY
sX
)(
)(
)(
)(
2
1
(2)
where
Fig.8 Analytical model
)2)(2(
2
222
22
111 ωωζωωζ  sssA
})1{(2
}))({(
2
1
2
22
22
2
2
2
22
1
2
ωγωζ
γωωω


ss
sssB
)2(2
2
222
2
11 ωωζωζ  sssC
)2)(2(
2
222
2
111 ωωζωωζ  ssD
where mkc 2/ is the damping ratio and
mk / is the natural circular frequency.  is
the mass ratio of the second floor to the first floor
m2/m1.
3.2 Estimation of parameters
Acceleration amplitude ratios of the first
floor and the second floor are obtained using the
frequency transfer functions. Parameters of the
analytical model are estimated using the frequency
response function obtained experimentally.
Parameters are estimated by fitting the peaks of the
frequency response function obtained from
experiment and that using Eq.(2). The peak of the
first vibration mode is focused on to estimate
parameters.
It is necessary for each parameter 1 and
2 , )/2( 11 f and )/2( 22 f to fit the peaks of
the frequency response function obtained from the
experiment and using Eq.(2). The mass ratio  is
fixed as 0.288 which is the mass ratio of an actual
experimental device.
Parameters are obtained using the frequency
response function of each floor and determined as the
average of these values. The results for each
condition are shown in Table 2. Figure.9 shows an
example of the frequency response functions of the
first floor, with MOD. Solid line shows the frequency
response function using Eq.(2) and broken line shows
that obtained from experiment. The frequency
response function obtained using Eq.(2) agrees well
with that from experiment.
Table.2 Parameters estimated form the frequency
response
3.3 Numerical results
The response of the first floor and that of the
second floor are obtained using El Centro EW (1940)
shown in Fig.10. Figure.11 and Fig.12 show absolute
acceleration responses of the first floor without
damper and with MOD, respectively. The response is
reduced when MOD is used.
Experimental
condition
Amplitude ratio
(dB)
Damping ratio
First floor
Vibration
mode
First
mode
Second
mode
First
mode
Second
mode
Without 26.6 20.0 0.0345 0.0097
Magnet 24.6 18.1 0.0614 0.0116
Oil 20.8 16.3 0.0790 0.0087
MOD 19.7 13.5 0.0862 0.0174
Second floor
Vibration
mode
First
mode
Second
mode
First
mode
Second
mode
Without 26.6 20.6 0.0345 0.0116
Magnet 23.9 19.6 0.0614 0.0116
Oil 20.0 17.8 0.0790 0.0116
MOD 19.7 14.8 0.0776 0.0203
Damping ratio Natural frequency
(Hz)
1 2 f1 f2
Without 0.0270 0.00001 6.60 14.88
Magnet 0.0352 0.00001 6.60 14.88
Oil 0.0554 0.00001 6.62 14.88
MOD 0.0559 0.00001 6.73 14.88
Shigeru Aoki, Katsumi Kurita / International Journal of Engineering Research and
Applications (IJERA) ISSN: 2248-9622 www.ijera.com
Vol. 3, Issue 4, Jul-Aug 2013, pp.2182-2188
2186 | P a g e
Table 3 shows the maximum acceleration
responses of the first floor and the second floor for all
experimental conditions. For all dampers, the
maximum responses are reduced when dampers are
used. Reduction rate of the response of the system
with MOD is largest. Reduction effect of the dampers
on the second floor is comparable to the first floor.
Table.3 Maximum acceleration response
IV. CONCLUSIONS
As new device for reduction of vibration of
the two story houses, the Magnet Oil Damper (MOD)
is proposed in which permanent magnets are added to
the oil damper in order to improve the performance
of the oil damper. The validity of MOD is examined
by experiment and numerical simulation. For
comparison, the magnet damper and oil damper are
used.
From experiment, the responses of house are
reduced when dampers are used. Reduction rate of
the response of the system with MOD is largest.
Reduction effect of MOD on the second floor is
comparable to the first floor.
In numerical simulation, parameters of an
analytical model are determined by fitting the peaks
of the frequency response function obtained from the
experiment and using Eq.(2). The validity of MOD is
examined using the actual seismic wave as the input.
In all results, the responses are reduced when
dampers are used. Reduction rate of the response of
the system with MOD is largest. Reduction effect of
the dampers on the second floor is comparable to the
first floor.
ACKNOWLEDGEMENT
The authors wish to thank Mr. Ken’ichi
Shimizu, a former student in Advanced Program of
Tokyo Metropolitan College of Industrial
Technology, for his contribution to the research of
this paper.
REFERENCES
[1] Othman,A.B., Property Profile of a
Laminated Rubber Bearing, Polymer Testing,
20(2), 2001, 159-166.
[2] Iizuka,M., A Macroscopic Model for
Predicting Large-deformation Behaviors
of Laminated Rubber Bearings,
Engineering Structures, 22(4), 2000,
323-334.
[3] Chang,C-H., Modeling of Laminated
Rubber Bearings Using an Analytical
Stiffness Matrix, International Journal of
Solids and Structures, 39(24), 2002.
[4] Soong,T.T. and Dargush,G.F., Passive
Energy Dissipation Systems in Structural
Fig.9 Frequency response function (with MOD, first floor)
Experimental
condition
Maximum acceleration
response (m/s2
)
First floor Second floor
Without 3.18 4.70
Magnet 2.63 3.93
Oil 2.59 4.05
MOD 2.50 3.87
Shigeru Aoki, Katsumi Kurita / International Journal of Engineering Research and
Applications (IJERA) ISSN: 2248-9622 www.ijera.com
Vol. 3, Issue 4, Jul-Aug 2013, pp.2182-2188
2187 | P a g e
Engineering, (Chichester: John Wiley &
Sons, 1997).
[5] Kawazoe,K., Kono,I., Aida,T., Aso,T. and
Ebisuda,K., Beam-type Dynamic Vibration
Absorber Composed of Free-free Beam,
Journal of Engineering Mechanics, ASCE,
124(4), 1998, pp.476-479.
[6] Wong,W.O. and Cheung,Y.L., Optimal
Design of a Damped Dynamic Vibration
Absorber for Vibration Control of
Structure Excited by Ground Motion,
Engineering Structures, 30(1), 2008,
282-286.
[7] Liu,K. and Liu,J., The Damped Dynamic
Vibration Absorbers: Revisited and New
Result, Journal of Sound and Vibration,
284(3-5), 2005, 1181-1189.
[8] Korenv,B.G. and Reznikov,L.M., Dynamic
Vibration Absorbers, (Chichester: John
Wiley & Sons, 1993).
[9] Reed,D., Yu,J., Yeh,H. and Gardarsson,S.,
Investigation of Tuned Liquid Dampers
under Large Amplitude Excitation, Journal
of Engineering Mechanics, ASCE, .124(4),
1998, 405-413.
[10] Li,C. and Liu,Y., Ground Motion Dominant
Frequency Effect on the Design of Multiple
Tuned Mass Dampers, Journal of
Earthquake Engineering, 8(1), 2004, 89-105.
[11] Masri,S.F., Theory of the Dynamic
Vibration Neutralizer with Motion Limiting
Stops, Transactions of ASME, Journal of
Applied Mechanics, 39, 1972, .563-568.
[12] Calvi,G.M., Ceresa,P., Casarotti,C.,
Bolognini,D. and Auricchio,F., Effects of
Axial Force Variation in the Seismic
Response of Bridges Isolated with Friction
Pendulum Systems, Journal of Earthquake
Engineering, 8(Special Issue 1), 2004, 187-
224.
[13] Wong,K.K.F., Seismic Energy Dissipation
of Inelastic Structures with Tuned Mass
Dampers, Journal of Engineering
Mechanics, ASCE, 134(2), 2008, 163-172.
[14] Aoki,S., Iwanami,K. and Sakakibara,K.,
Passive Control for Seismic Response of
House with Oil Damper, Proceedings of
International Conference on
Instrumentation, Control and Information
Technology (SICE Annual Conference 2008),
Tokyo, 2008, pp.11733-1736.
[15] Aoki,S., Kurita,K. and Yokoyama,Y.,
Reduction of Vibration of Structure using
Oil Damper (Examination from Simulation
Method), Proceedings of the 10th
International Conference on Motion and
Vibration Control, Tokyo, 2010, CD-ROM
1A13.
[16] Iwanami,K., Development of Swing Type
Damper with Attenuation Characteristic for
Multi-dimension, Reports of Tokyo
Metropolitan College of Technology, 41,
2005, pp.55-61.
Shigeru Aoki, Katsumi Kurita / International Journal of Engineering Research and
Applications (IJERA) ISSN: 2248-9622 www.ijera.com
Vol. 3, Issue 4, Jul-Aug 2013, pp.2182-2188
2188 | P a g e

Más contenido relacionado

Destacado

Destacado (20)

Fz3111631166
Fz3111631166Fz3111631166
Fz3111631166
 
Fw3111471149
Fw3111471149Fw3111471149
Fw3111471149
 
Gd3111841188
Gd3111841188Gd3111841188
Gd3111841188
 
Gb3111731177
Gb3111731177Gb3111731177
Gb3111731177
 
Gq3112761281
Gq3112761281Gq3112761281
Gq3112761281
 
Gi3112131218
Gi3112131218Gi3112131218
Gi3112131218
 
Gj3112191223
Gj3112191223Gj3112191223
Gj3112191223
 
Expo maq-3
Expo maq-3Expo maq-3
Expo maq-3
 
Curso de caligrafia
Curso de caligrafiaCurso de caligrafia
Curso de caligrafia
 
212 Dental Care - 212DentalCare.net - Website Prevew
212 Dental Care - 212DentalCare.net - Website Prevew212 Dental Care - 212DentalCare.net - Website Prevew
212 Dental Care - 212DentalCare.net - Website Prevew
 
Unid 3 ativ_2_luciana
Unid 3 ativ_2_lucianaUnid 3 ativ_2_luciana
Unid 3 ativ_2_luciana
 
Transmilenio ¿la nueva alternativa y solución alla movilidad de Bogotá?
Transmilenio ¿la nueva alternativa y solución alla movilidad de Bogotá?Transmilenio ¿la nueva alternativa y solución alla movilidad de Bogotá?
Transmilenio ¿la nueva alternativa y solución alla movilidad de Bogotá?
 
Guia tranversal de español
Guia tranversal de españolGuia tranversal de español
Guia tranversal de español
 
GUERNICA
GUERNICAGUERNICA
GUERNICA
 
Generacion de poder
Generacion de poderGeneracion de poder
Generacion de poder
 
Niles West Honors Convocation 1985
Niles West Honors Convocation 1985Niles West Honors Convocation 1985
Niles West Honors Convocation 1985
 
Seo & Content Marketing Opleiding
Seo & Content Marketing OpleidingSeo & Content Marketing Opleiding
Seo & Content Marketing Opleiding
 
Apresentação 'BT in SME'
Apresentação 'BT in SME'Apresentação 'BT in SME'
Apresentação 'BT in SME'
 
cumpleaños
cumpleañoscumpleaños
cumpleaños
 
MAABE
MAABEMAABE
MAABE
 

Similar a Me3421822188

IRJET- Replacement of Course and Fine Aggregates in Concrete by using Mangalo...
IRJET- Replacement of Course and Fine Aggregates in Concrete by using Mangalo...IRJET- Replacement of Course and Fine Aggregates in Concrete by using Mangalo...
IRJET- Replacement of Course and Fine Aggregates in Concrete by using Mangalo...IRJET Journal
 
IRJET - Comparison of Seismic Behavior of Multi-Storey Structure with Com...
IRJET -  	  Comparison of Seismic Behavior of Multi-Storey Structure with Com...IRJET -  	  Comparison of Seismic Behavior of Multi-Storey Structure with Com...
IRJET - Comparison of Seismic Behavior of Multi-Storey Structure with Com...IRJET Journal
 
IRJET - Seismic Analysis of Different Shape of RC Building by using the Visco...
IRJET - Seismic Analysis of Different Shape of RC Building by using the Visco...IRJET - Seismic Analysis of Different Shape of RC Building by using the Visco...
IRJET - Seismic Analysis of Different Shape of RC Building by using the Visco...IRJET Journal
 
IRJET- Behaviour of Self Cleaning Concrete by using Various Photocatalysts
IRJET-  	  Behaviour of Self Cleaning Concrete by using Various PhotocatalystsIRJET-  	  Behaviour of Self Cleaning Concrete by using Various Photocatalysts
IRJET- Behaviour of Self Cleaning Concrete by using Various PhotocatalystsIRJET Journal
 
IRJET- Seismic Performance of Building using Accordion Metallic Damper
IRJET-  	  Seismic Performance of Building using Accordion Metallic DamperIRJET-  	  Seismic Performance of Building using Accordion Metallic Damper
IRJET- Seismic Performance of Building using Accordion Metallic DamperIRJET Journal
 
IRJET- Seismic Performance of Building using Accordion Metallic Damper
IRJET-  	  Seismic Performance of Building using Accordion Metallic DamperIRJET-  	  Seismic Performance of Building using Accordion Metallic Damper
IRJET- Seismic Performance of Building using Accordion Metallic DamperIRJET Journal
 
Study on Concentric Steel Bracing at Soft Storey During Earthquake
Study on Concentric Steel Bracing at Soft Storey During EarthquakeStudy on Concentric Steel Bracing at Soft Storey During Earthquake
Study on Concentric Steel Bracing at Soft Storey During EarthquakeIRJET Journal
 
IRJET- Static and Dynamic Analysis of Wind Energy Building under the Action o...
IRJET- Static and Dynamic Analysis of Wind Energy Building under the Action o...IRJET- Static and Dynamic Analysis of Wind Energy Building under the Action o...
IRJET- Static and Dynamic Analysis of Wind Energy Building under the Action o...IRJET Journal
 
Seismic Performance Study on RC Chimney
Seismic Performance Study on RC ChimneySeismic Performance Study on RC Chimney
Seismic Performance Study on RC ChimneyIRJET Journal
 
Modeling and finite element analysis for a casting defect in thin wall struct...
Modeling and finite element analysis for a casting defect in thin wall struct...Modeling and finite element analysis for a casting defect in thin wall struct...
Modeling and finite element analysis for a casting defect in thin wall struct...Dr.Vikas Deulgaonkar
 
ANALYSIS OF THERMAL PERFORMANCE OF SOLAR COLLECTOR WITH LONGITUDINAL FINS
ANALYSIS OF THERMAL PERFORMANCE OF SOLAR COLLECTOR WITH LONGITUDINAL FINSANALYSIS OF THERMAL PERFORMANCE OF SOLAR COLLECTOR WITH LONGITUDINAL FINS
ANALYSIS OF THERMAL PERFORMANCE OF SOLAR COLLECTOR WITH LONGITUDINAL FINSIRJET Journal
 
Behaviour of M30 Grade concrete with confinement under axial compression
Behaviour of M30 Grade concrete with confinement under axial compressionBehaviour of M30 Grade concrete with confinement under axial compression
Behaviour of M30 Grade concrete with confinement under axial compressionIJERA Editor
 
Experimental Inspection by using the Effect of Magnetic Field on the Performa...
Experimental Inspection by using the Effect of Magnetic Field on the Performa...Experimental Inspection by using the Effect of Magnetic Field on the Performa...
Experimental Inspection by using the Effect of Magnetic Field on the Performa...IRJET Journal
 
Dx3212201228
Dx3212201228Dx3212201228
Dx3212201228IJMER
 
Utilization of Industrial By-Products as Sand Replacement on Properties of co...
Utilization of Industrial By-Products as Sand Replacement on Properties of co...Utilization of Industrial By-Products as Sand Replacement on Properties of co...
Utilization of Industrial By-Products as Sand Replacement on Properties of co...IRJET Journal
 
Utilization of Industrial By-Products as Sand Replacement on Properties of co...
Utilization of Industrial By-Products as Sand Replacement on Properties of co...Utilization of Industrial By-Products as Sand Replacement on Properties of co...
Utilization of Industrial By-Products as Sand Replacement on Properties of co...IRJET Journal
 
IRJET- Experimental Investigation on the Usage of Vermiculite Waste in Co...
IRJET-  	  Experimental Investigation on the Usage of Vermiculite Waste in Co...IRJET-  	  Experimental Investigation on the Usage of Vermiculite Waste in Co...
IRJET- Experimental Investigation on the Usage of Vermiculite Waste in Co...IRJET Journal
 
IRJET- Effective Control of Response of a Building Under Wind Vibration using...
IRJET- Effective Control of Response of a Building Under Wind Vibration using...IRJET- Effective Control of Response of a Building Under Wind Vibration using...
IRJET- Effective Control of Response of a Building Under Wind Vibration using...IRJET Journal
 
Optimization of Seismic Response by Steel Framed Structures on Sloping Ground
Optimization of Seismic Response by Steel Framed Structures on Sloping GroundOptimization of Seismic Response by Steel Framed Structures on Sloping Ground
Optimization of Seismic Response by Steel Framed Structures on Sloping GroundIRJET Journal
 

Similar a Me3421822188 (20)

IRJET- Replacement of Course and Fine Aggregates in Concrete by using Mangalo...
IRJET- Replacement of Course and Fine Aggregates in Concrete by using Mangalo...IRJET- Replacement of Course and Fine Aggregates in Concrete by using Mangalo...
IRJET- Replacement of Course and Fine Aggregates in Concrete by using Mangalo...
 
IRJET - Comparison of Seismic Behavior of Multi-Storey Structure with Com...
IRJET -  	  Comparison of Seismic Behavior of Multi-Storey Structure with Com...IRJET -  	  Comparison of Seismic Behavior of Multi-Storey Structure with Com...
IRJET - Comparison of Seismic Behavior of Multi-Storey Structure with Com...
 
IRJET - Seismic Analysis of Different Shape of RC Building by using the Visco...
IRJET - Seismic Analysis of Different Shape of RC Building by using the Visco...IRJET - Seismic Analysis of Different Shape of RC Building by using the Visco...
IRJET - Seismic Analysis of Different Shape of RC Building by using the Visco...
 
IRJET- Behaviour of Self Cleaning Concrete by using Various Photocatalysts
IRJET-  	  Behaviour of Self Cleaning Concrete by using Various PhotocatalystsIRJET-  	  Behaviour of Self Cleaning Concrete by using Various Photocatalysts
IRJET- Behaviour of Self Cleaning Concrete by using Various Photocatalysts
 
Bk24399408
Bk24399408Bk24399408
Bk24399408
 
IRJET- Seismic Performance of Building using Accordion Metallic Damper
IRJET-  	  Seismic Performance of Building using Accordion Metallic DamperIRJET-  	  Seismic Performance of Building using Accordion Metallic Damper
IRJET- Seismic Performance of Building using Accordion Metallic Damper
 
IRJET- Seismic Performance of Building using Accordion Metallic Damper
IRJET-  	  Seismic Performance of Building using Accordion Metallic DamperIRJET-  	  Seismic Performance of Building using Accordion Metallic Damper
IRJET- Seismic Performance of Building using Accordion Metallic Damper
 
Study on Concentric Steel Bracing at Soft Storey During Earthquake
Study on Concentric Steel Bracing at Soft Storey During EarthquakeStudy on Concentric Steel Bracing at Soft Storey During Earthquake
Study on Concentric Steel Bracing at Soft Storey During Earthquake
 
IRJET- Static and Dynamic Analysis of Wind Energy Building under the Action o...
IRJET- Static and Dynamic Analysis of Wind Energy Building under the Action o...IRJET- Static and Dynamic Analysis of Wind Energy Building under the Action o...
IRJET- Static and Dynamic Analysis of Wind Energy Building under the Action o...
 
Seismic Performance Study on RC Chimney
Seismic Performance Study on RC ChimneySeismic Performance Study on RC Chimney
Seismic Performance Study on RC Chimney
 
Modeling and finite element analysis for a casting defect in thin wall struct...
Modeling and finite element analysis for a casting defect in thin wall struct...Modeling and finite element analysis for a casting defect in thin wall struct...
Modeling and finite element analysis for a casting defect in thin wall struct...
 
ANALYSIS OF THERMAL PERFORMANCE OF SOLAR COLLECTOR WITH LONGITUDINAL FINS
ANALYSIS OF THERMAL PERFORMANCE OF SOLAR COLLECTOR WITH LONGITUDINAL FINSANALYSIS OF THERMAL PERFORMANCE OF SOLAR COLLECTOR WITH LONGITUDINAL FINS
ANALYSIS OF THERMAL PERFORMANCE OF SOLAR COLLECTOR WITH LONGITUDINAL FINS
 
Behaviour of M30 Grade concrete with confinement under axial compression
Behaviour of M30 Grade concrete with confinement under axial compressionBehaviour of M30 Grade concrete with confinement under axial compression
Behaviour of M30 Grade concrete with confinement under axial compression
 
Experimental Inspection by using the Effect of Magnetic Field on the Performa...
Experimental Inspection by using the Effect of Magnetic Field on the Performa...Experimental Inspection by using the Effect of Magnetic Field on the Performa...
Experimental Inspection by using the Effect of Magnetic Field on the Performa...
 
Dx3212201228
Dx3212201228Dx3212201228
Dx3212201228
 
Utilization of Industrial By-Products as Sand Replacement on Properties of co...
Utilization of Industrial By-Products as Sand Replacement on Properties of co...Utilization of Industrial By-Products as Sand Replacement on Properties of co...
Utilization of Industrial By-Products as Sand Replacement on Properties of co...
 
Utilization of Industrial By-Products as Sand Replacement on Properties of co...
Utilization of Industrial By-Products as Sand Replacement on Properties of co...Utilization of Industrial By-Products as Sand Replacement on Properties of co...
Utilization of Industrial By-Products as Sand Replacement on Properties of co...
 
IRJET- Experimental Investigation on the Usage of Vermiculite Waste in Co...
IRJET-  	  Experimental Investigation on the Usage of Vermiculite Waste in Co...IRJET-  	  Experimental Investigation on the Usage of Vermiculite Waste in Co...
IRJET- Experimental Investigation on the Usage of Vermiculite Waste in Co...
 
IRJET- Effective Control of Response of a Building Under Wind Vibration using...
IRJET- Effective Control of Response of a Building Under Wind Vibration using...IRJET- Effective Control of Response of a Building Under Wind Vibration using...
IRJET- Effective Control of Response of a Building Under Wind Vibration using...
 
Optimization of Seismic Response by Steel Framed Structures on Sloping Ground
Optimization of Seismic Response by Steel Framed Structures on Sloping GroundOptimization of Seismic Response by Steel Framed Structures on Sloping Ground
Optimization of Seismic Response by Steel Framed Structures on Sloping Ground
 

Último

From Family Reminiscence to Scholarly Archive .
From Family Reminiscence to Scholarly Archive .From Family Reminiscence to Scholarly Archive .
From Family Reminiscence to Scholarly Archive .Alan Dix
 
The State of Passkeys with FIDO Alliance.pptx
The State of Passkeys with FIDO Alliance.pptxThe State of Passkeys with FIDO Alliance.pptx
The State of Passkeys with FIDO Alliance.pptxLoriGlavin3
 
Scanning the Internet for External Cloud Exposures via SSL Certs
Scanning the Internet for External Cloud Exposures via SSL CertsScanning the Internet for External Cloud Exposures via SSL Certs
Scanning the Internet for External Cloud Exposures via SSL CertsRizwan Syed
 
Merck Moving Beyond Passwords: FIDO Paris Seminar.pptx
Merck Moving Beyond Passwords: FIDO Paris Seminar.pptxMerck Moving Beyond Passwords: FIDO Paris Seminar.pptx
Merck Moving Beyond Passwords: FIDO Paris Seminar.pptxLoriGlavin3
 
Unraveling Multimodality with Large Language Models.pdf
Unraveling Multimodality with Large Language Models.pdfUnraveling Multimodality with Large Language Models.pdf
Unraveling Multimodality with Large Language Models.pdfAlex Barbosa Coqueiro
 
DSPy a system for AI to Write Prompts and Do Fine Tuning
DSPy a system for AI to Write Prompts and Do Fine TuningDSPy a system for AI to Write Prompts and Do Fine Tuning
DSPy a system for AI to Write Prompts and Do Fine TuningLars Bell
 
Moving Beyond Passwords: FIDO Paris Seminar.pdf
Moving Beyond Passwords: FIDO Paris Seminar.pdfMoving Beyond Passwords: FIDO Paris Seminar.pdf
Moving Beyond Passwords: FIDO Paris Seminar.pdfLoriGlavin3
 
Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024BookNet Canada
 
Advanced Computer Architecture – An Introduction
Advanced Computer Architecture – An IntroductionAdvanced Computer Architecture – An Introduction
Advanced Computer Architecture – An IntroductionDilum Bandara
 
The Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptx
The Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptxThe Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptx
The Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptxLoriGlavin3
 
Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?Mattias Andersson
 
Generative AI for Technical Writer or Information Developers
Generative AI for Technical Writer or Information DevelopersGenerative AI for Technical Writer or Information Developers
Generative AI for Technical Writer or Information DevelopersRaghuram Pandurangan
 
DevoxxFR 2024 Reproducible Builds with Apache Maven
DevoxxFR 2024 Reproducible Builds with Apache MavenDevoxxFR 2024 Reproducible Builds with Apache Maven
DevoxxFR 2024 Reproducible Builds with Apache MavenHervé Boutemy
 
TeamStation AI System Report LATAM IT Salaries 2024
TeamStation AI System Report LATAM IT Salaries 2024TeamStation AI System Report LATAM IT Salaries 2024
TeamStation AI System Report LATAM IT Salaries 2024Lonnie McRorey
 
"Debugging python applications inside k8s environment", Andrii Soldatenko
"Debugging python applications inside k8s environment", Andrii Soldatenko"Debugging python applications inside k8s environment", Andrii Soldatenko
"Debugging python applications inside k8s environment", Andrii SoldatenkoFwdays
 
New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024
New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024
New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024BookNet Canada
 
Unleash Your Potential - Namagunga Girls Coding Club
Unleash Your Potential - Namagunga Girls Coding ClubUnleash Your Potential - Namagunga Girls Coding Club
Unleash Your Potential - Namagunga Girls Coding ClubKalema Edgar
 
How AI, OpenAI, and ChatGPT impact business and software.
How AI, OpenAI, and ChatGPT impact business and software.How AI, OpenAI, and ChatGPT impact business and software.
How AI, OpenAI, and ChatGPT impact business and software.Curtis Poe
 
SALESFORCE EDUCATION CLOUD | FEXLE SERVICES
SALESFORCE EDUCATION CLOUD | FEXLE SERVICESSALESFORCE EDUCATION CLOUD | FEXLE SERVICES
SALESFORCE EDUCATION CLOUD | FEXLE SERVICESmohitsingh558521
 
"Subclassing and Composition – A Pythonic Tour of Trade-Offs", Hynek Schlawack
"Subclassing and Composition – A Pythonic Tour of Trade-Offs", Hynek Schlawack"Subclassing and Composition – A Pythonic Tour of Trade-Offs", Hynek Schlawack
"Subclassing and Composition – A Pythonic Tour of Trade-Offs", Hynek SchlawackFwdays
 

Último (20)

From Family Reminiscence to Scholarly Archive .
From Family Reminiscence to Scholarly Archive .From Family Reminiscence to Scholarly Archive .
From Family Reminiscence to Scholarly Archive .
 
The State of Passkeys with FIDO Alliance.pptx
The State of Passkeys with FIDO Alliance.pptxThe State of Passkeys with FIDO Alliance.pptx
The State of Passkeys with FIDO Alliance.pptx
 
Scanning the Internet for External Cloud Exposures via SSL Certs
Scanning the Internet for External Cloud Exposures via SSL CertsScanning the Internet for External Cloud Exposures via SSL Certs
Scanning the Internet for External Cloud Exposures via SSL Certs
 
Merck Moving Beyond Passwords: FIDO Paris Seminar.pptx
Merck Moving Beyond Passwords: FIDO Paris Seminar.pptxMerck Moving Beyond Passwords: FIDO Paris Seminar.pptx
Merck Moving Beyond Passwords: FIDO Paris Seminar.pptx
 
Unraveling Multimodality with Large Language Models.pdf
Unraveling Multimodality with Large Language Models.pdfUnraveling Multimodality with Large Language Models.pdf
Unraveling Multimodality with Large Language Models.pdf
 
DSPy a system for AI to Write Prompts and Do Fine Tuning
DSPy a system for AI to Write Prompts and Do Fine TuningDSPy a system for AI to Write Prompts and Do Fine Tuning
DSPy a system for AI to Write Prompts and Do Fine Tuning
 
Moving Beyond Passwords: FIDO Paris Seminar.pdf
Moving Beyond Passwords: FIDO Paris Seminar.pdfMoving Beyond Passwords: FIDO Paris Seminar.pdf
Moving Beyond Passwords: FIDO Paris Seminar.pdf
 
Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
 
Advanced Computer Architecture – An Introduction
Advanced Computer Architecture – An IntroductionAdvanced Computer Architecture – An Introduction
Advanced Computer Architecture – An Introduction
 
The Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptx
The Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptxThe Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptx
The Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptx
 
Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?
 
Generative AI for Technical Writer or Information Developers
Generative AI for Technical Writer or Information DevelopersGenerative AI for Technical Writer or Information Developers
Generative AI for Technical Writer or Information Developers
 
DevoxxFR 2024 Reproducible Builds with Apache Maven
DevoxxFR 2024 Reproducible Builds with Apache MavenDevoxxFR 2024 Reproducible Builds with Apache Maven
DevoxxFR 2024 Reproducible Builds with Apache Maven
 
TeamStation AI System Report LATAM IT Salaries 2024
TeamStation AI System Report LATAM IT Salaries 2024TeamStation AI System Report LATAM IT Salaries 2024
TeamStation AI System Report LATAM IT Salaries 2024
 
"Debugging python applications inside k8s environment", Andrii Soldatenko
"Debugging python applications inside k8s environment", Andrii Soldatenko"Debugging python applications inside k8s environment", Andrii Soldatenko
"Debugging python applications inside k8s environment", Andrii Soldatenko
 
New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024
New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024
New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024
 
Unleash Your Potential - Namagunga Girls Coding Club
Unleash Your Potential - Namagunga Girls Coding ClubUnleash Your Potential - Namagunga Girls Coding Club
Unleash Your Potential - Namagunga Girls Coding Club
 
How AI, OpenAI, and ChatGPT impact business and software.
How AI, OpenAI, and ChatGPT impact business and software.How AI, OpenAI, and ChatGPT impact business and software.
How AI, OpenAI, and ChatGPT impact business and software.
 
SALESFORCE EDUCATION CLOUD | FEXLE SERVICES
SALESFORCE EDUCATION CLOUD | FEXLE SERVICESSALESFORCE EDUCATION CLOUD | FEXLE SERVICES
SALESFORCE EDUCATION CLOUD | FEXLE SERVICES
 
"Subclassing and Composition – A Pythonic Tour of Trade-Offs", Hynek Schlawack
"Subclassing and Composition – A Pythonic Tour of Trade-Offs", Hynek Schlawack"Subclassing and Composition – A Pythonic Tour of Trade-Offs", Hynek Schlawack
"Subclassing and Composition – A Pythonic Tour of Trade-Offs", Hynek Schlawack
 

Me3421822188

  • 1. Shigeru Aoki, Katsumi Kurita / International Journal of Engineering Research and Applications (IJERA) ISSN: 2248-9622 www.ijera.com Vol. 3, Issue 4, Jul-Aug 2013, pp.2182-2188 2182 | P a g e Effect Of Magnet And Oil Damper On Reduction Of Seismic Response Of Houses Shigeru Aoki*, Katsumi Kurita* *Department of Mechanical Engineering, Tokyo Metropolitan College of Industrial Technology, Japan ABSTRACT It is important to reduce the seismic response of houses in order to prevent from collapse of houses. Some control methods for seismic response of houses are developed. The oil dampers using the flow resistance of the silicon oil have been developed. In this paper, a Magnet Oil Damper (MOD) in which permanent magnets are added to the oil damper is proposed in order to improve the performance of the oil damper. MOD is installed in two-story house. The effect of MOD is examined experimentally. The peaks of resonance curves are reduced when MOD is used. The effectiveness of MOD is examined by numerical simulation using the analytical model. The response of the house subjected to actual earthquake excitation decreases when MOD is used. Keywords - Damper, Earthquake resistant, Forced vibration, Frequency response function, Seismic motion I. INTRODUCTION In recent years, destructive earthquake disasters have happened in the world. A lot of houses are collapsed under large earthquakes. It is important to reduce the seismic response of houses in order to prevent from collapse of houses. Some reduction methods for seismic response of houses are developed, for example, laminated rubber bearings are used[1]-[3]. Other types of passive dampers are proposed[4]. Design methods for dynamic vibration absorbers[5]-[8] and tuned mass dampers[9][10] are proposed. Some devices utilize nonlinear characteristics, impact[11], friction[12] and plastic deformation[13]. For residence, two-story houses are general in Japan. It is required that construction and maintenance of the dampers are easy, especially for the dampers for low rise houses. The authors have proposed the oil dampers using the flow resistance of the silicon oil. The oil dampers are fixed on the foundation and connected to ceiling of first floor with connecting rod. The oil dampers are easily installed in the houses even if the houses have been built up. The effect of the oil damper on reduction of seismic response is presented in the previous the papers[14][15]. In this paper, a Magnet Oil Damper (MOD) in which permanent magnets are added to the oil damper is proposed in order to improve the performance of the oil damper. The neodymium magnets are used inside of the oil damper. The effect of MOD is examined experimentally. A model of two-story house is made and MOD is fixed on the foundation. The model is excited horizontally and the resonance curves including the first and second vibration modes are measured. For comparison, a model without damper, with magnet damper (without oil), oil damper (without magnet) and MOD are used. The peaks of the resonance curves are reduced when the dampers are used. When MOD is used, reduction rate is largest. The damping ratio is also obtained. The damping ratio is largest when MOD is used. Next, the effectiveness of MOD is examined by numerical simulation. Two-story house with damper is modeled as a two-degree-of-freedom system. Seismic responses of the two story house are obtained using actual earthquake excitations as input. It is demonstrated that seismic responses are reduced when MOD is used. II. EXPERIMENTAL SETUP Two story houses are focused on and a new type of damper, MOD, using silicon oil and permanent magnets is proposed. The effectiveness of MOD is examined experimentally. An experimental model of two-story house is made and some types of dampers are fixed on the foundation and connected to the model of the ceiling of the first floor with connecting rod. These types of the dampers are easily installed in the houses even if the houses have been built up. 2.1 Design and structure of MOD A new damper that uses permanent magnets and the silicon oil is designed. Damper is designed to move only in one direction so that movement of the damper is steady. Figure 1 shows shape and the size of MOD. Figure 2 shows names of parts in the main portion of MOD. Figure 3 shows a photograph of parts of MOD. For a viscous material of the damper, the silicon oil of kinematic viscosity 30000cst is used. Two neodymium magnets are installed in the damper and the inner wall of the pool, respectively, as shown Fig.2.
  • 2. Shigeru Aoki, Katsumi Kurita / International Journal of Engineering Research and Applications (IJERA) ISSN: 2248-9622 www.ijera.com Vol. 3, Issue 4, Jul-Aug 2013, pp.2182-2188 2183 | P a g e 2.2 Principle of MOD MOD is fixed on the foundation of the experimental model of two-story house. As shown in Fig.1, a connecting rod is installed in the rectangular solid at one end and connected to the model of the ceiling of the first floor at the other end. The connecting point is rolling joint. The self-aligning ball bearing is used. A fit between the bearing and the connecting rod is loose fit considering vertical motion[16]. The connecting rod is shaken around the bearing as fulcrum as shown in Fig.4. As a result, the damping force is caused by resistance on the surface of the rectangular solid and the flow resistance of the silicon oil in the damper according to the movement of the rectangular solid. In addition, the magnets are installed in the rectangular solid and the inner wall Fig.1 Size and shape of Magnet Oil Damper (mm) Fig.3 Parts of MOD Rectangular solid Main parts Connecting rod Connecting point to the ceiling of the first floor
  • 3. Shigeru Aoki, Katsumi Kurita / International Journal of Engineering Research and Applications (IJERA) ISSN: 2248-9622 www.ijera.com Vol. 3, Issue 4, Jul-Aug 2013, pp.2182-2188 2184 | P a g e of the pool with same polar and repulse mutually. These resistances and the repulsion force cause the damping force which reduces the vibration. 2.3 Structural model of house Figure 5 shows shape and the size of the experimental model of two-story house. The size of foundation is 250×250×25mm. The size of the first floor part and the second floor part is 250×250×10mm. The size of the pillars is 250×25×3mm. The size of the model is determined considering the fundamental natural frequency of ordinary Japanese houses. 2.4 Experimental method The model of two-story house is set on the shaking table as shown in Fig.6. MOD is fixed on the foundation and connected to the model of the ceiling of the first floor with connecting rod. The model is shaken in horizontal direction. The acceleration pickups are fixed by bolt on side of the foundation, the first floor and the second floor of the model. The excitation frequency is changed from 1 to 25 Hz, and the acceleration response amplitude is measured. The graphs of the acceleration response amplitude ratio of the first floor, and the second floor to the foundation are drawn from the outcome of the experiment. Responses of four conditions (case without damper, case with magnet damper, case with oil damper and case with MOD) are measured respectively. The result of a measurement in each condition is compared. The excitation amplitude is 1mm at 1Hz. Fig.7 Amplitude ratio of first floor 2.5 Results of experiment A comparative example of the acceleration response amplitude ratio of the first floor (frequency response function) is shown in Fig.7. Solid line shows results for the case with MOD and broken line shows for the case without damper. The peaks of the first vibration mode and the second vibration mode decrease when MOD is used. Table 1 shows peaks of the acceleration response amplitude ratios and the damping ratios of the first vibration mode and the second vibration mode. The damping ratio is obtained by the half power method. Comparing four conditions, the acceleration amplitude ratios at the peaks of the first vibration mode and the second vibration mode are reduced when the dampers are used. MOD is the most effective on reduction of the peaks of the first vibration mode and the second vibration mode.
  • 4. Shigeru Aoki, Katsumi Kurita / International Journal of Engineering Research and Applications (IJERA) ISSN: 2248-9622 www.ijera.com Vol. 3, Issue 4, Jul-Aug 2013, pp.2182-2188 2185 | P a g e Damping ratio of the system with MOD is about twice that without damper. Reduction effect of MOD on the second floor is comparable to the first floor. Table.1 Amplitude ratio and damping ratio III. NUMERICAL SIMULATION The effectiveness of the dampers is examined by numerical simulation using an analytical model. 3.1 Analytical model Two-story house with the damper is assumed to be modeled as a linear two-degree-of- freedom system shown in Fig.8. Equations of motion are given as:                  0 0 12212222 212112121111 xxkxxcxm xxkyxkxxcyxcxm   (1) where subscript 1 is for the first floor and 2 is for the second floor and m is mass, c is the damping coefficient, k is the spring constant and x is the absolute displacement of the floor, y is the absolute displacement of the ground. Frequency transfer functions are obtained as Eq.(2).            CB D sY sX CB A sY sX )( )( )( )( 2 1 (2) where Fig.8 Analytical model )2)(2( 2 222 22 111 ωωζωωζ  sssA })1{(2 }))({( 2 1 2 22 22 2 2 2 22 1 2 ωγωζ γωωω   ss sssB )2(2 2 222 2 11 ωωζωζ  sssC )2)(2( 2 222 2 111 ωωζωωζ  ssD where mkc 2/ is the damping ratio and mk / is the natural circular frequency.  is the mass ratio of the second floor to the first floor m2/m1. 3.2 Estimation of parameters Acceleration amplitude ratios of the first floor and the second floor are obtained using the frequency transfer functions. Parameters of the analytical model are estimated using the frequency response function obtained experimentally. Parameters are estimated by fitting the peaks of the frequency response function obtained from experiment and that using Eq.(2). The peak of the first vibration mode is focused on to estimate parameters. It is necessary for each parameter 1 and 2 , )/2( 11 f and )/2( 22 f to fit the peaks of the frequency response function obtained from the experiment and using Eq.(2). The mass ratio  is fixed as 0.288 which is the mass ratio of an actual experimental device. Parameters are obtained using the frequency response function of each floor and determined as the average of these values. The results for each condition are shown in Table 2. Figure.9 shows an example of the frequency response functions of the first floor, with MOD. Solid line shows the frequency response function using Eq.(2) and broken line shows that obtained from experiment. The frequency response function obtained using Eq.(2) agrees well with that from experiment. Table.2 Parameters estimated form the frequency response 3.3 Numerical results The response of the first floor and that of the second floor are obtained using El Centro EW (1940) shown in Fig.10. Figure.11 and Fig.12 show absolute acceleration responses of the first floor without damper and with MOD, respectively. The response is reduced when MOD is used. Experimental condition Amplitude ratio (dB) Damping ratio First floor Vibration mode First mode Second mode First mode Second mode Without 26.6 20.0 0.0345 0.0097 Magnet 24.6 18.1 0.0614 0.0116 Oil 20.8 16.3 0.0790 0.0087 MOD 19.7 13.5 0.0862 0.0174 Second floor Vibration mode First mode Second mode First mode Second mode Without 26.6 20.6 0.0345 0.0116 Magnet 23.9 19.6 0.0614 0.0116 Oil 20.0 17.8 0.0790 0.0116 MOD 19.7 14.8 0.0776 0.0203 Damping ratio Natural frequency (Hz) 1 2 f1 f2 Without 0.0270 0.00001 6.60 14.88 Magnet 0.0352 0.00001 6.60 14.88 Oil 0.0554 0.00001 6.62 14.88 MOD 0.0559 0.00001 6.73 14.88
  • 5. Shigeru Aoki, Katsumi Kurita / International Journal of Engineering Research and Applications (IJERA) ISSN: 2248-9622 www.ijera.com Vol. 3, Issue 4, Jul-Aug 2013, pp.2182-2188 2186 | P a g e Table 3 shows the maximum acceleration responses of the first floor and the second floor for all experimental conditions. For all dampers, the maximum responses are reduced when dampers are used. Reduction rate of the response of the system with MOD is largest. Reduction effect of the dampers on the second floor is comparable to the first floor. Table.3 Maximum acceleration response IV. CONCLUSIONS As new device for reduction of vibration of the two story houses, the Magnet Oil Damper (MOD) is proposed in which permanent magnets are added to the oil damper in order to improve the performance of the oil damper. The validity of MOD is examined by experiment and numerical simulation. For comparison, the magnet damper and oil damper are used. From experiment, the responses of house are reduced when dampers are used. Reduction rate of the response of the system with MOD is largest. Reduction effect of MOD on the second floor is comparable to the first floor. In numerical simulation, parameters of an analytical model are determined by fitting the peaks of the frequency response function obtained from the experiment and using Eq.(2). The validity of MOD is examined using the actual seismic wave as the input. In all results, the responses are reduced when dampers are used. Reduction rate of the response of the system with MOD is largest. Reduction effect of the dampers on the second floor is comparable to the first floor. ACKNOWLEDGEMENT The authors wish to thank Mr. Ken’ichi Shimizu, a former student in Advanced Program of Tokyo Metropolitan College of Industrial Technology, for his contribution to the research of this paper. REFERENCES [1] Othman,A.B., Property Profile of a Laminated Rubber Bearing, Polymer Testing, 20(2), 2001, 159-166. [2] Iizuka,M., A Macroscopic Model for Predicting Large-deformation Behaviors of Laminated Rubber Bearings, Engineering Structures, 22(4), 2000, 323-334. [3] Chang,C-H., Modeling of Laminated Rubber Bearings Using an Analytical Stiffness Matrix, International Journal of Solids and Structures, 39(24), 2002. [4] Soong,T.T. and Dargush,G.F., Passive Energy Dissipation Systems in Structural Fig.9 Frequency response function (with MOD, first floor) Experimental condition Maximum acceleration response (m/s2 ) First floor Second floor Without 3.18 4.70 Magnet 2.63 3.93 Oil 2.59 4.05 MOD 2.50 3.87
  • 6. Shigeru Aoki, Katsumi Kurita / International Journal of Engineering Research and Applications (IJERA) ISSN: 2248-9622 www.ijera.com Vol. 3, Issue 4, Jul-Aug 2013, pp.2182-2188 2187 | P a g e Engineering, (Chichester: John Wiley & Sons, 1997). [5] Kawazoe,K., Kono,I., Aida,T., Aso,T. and Ebisuda,K., Beam-type Dynamic Vibration Absorber Composed of Free-free Beam, Journal of Engineering Mechanics, ASCE, 124(4), 1998, pp.476-479. [6] Wong,W.O. and Cheung,Y.L., Optimal Design of a Damped Dynamic Vibration Absorber for Vibration Control of Structure Excited by Ground Motion, Engineering Structures, 30(1), 2008, 282-286. [7] Liu,K. and Liu,J., The Damped Dynamic Vibration Absorbers: Revisited and New Result, Journal of Sound and Vibration, 284(3-5), 2005, 1181-1189. [8] Korenv,B.G. and Reznikov,L.M., Dynamic Vibration Absorbers, (Chichester: John Wiley & Sons, 1993). [9] Reed,D., Yu,J., Yeh,H. and Gardarsson,S., Investigation of Tuned Liquid Dampers under Large Amplitude Excitation, Journal of Engineering Mechanics, ASCE, .124(4), 1998, 405-413. [10] Li,C. and Liu,Y., Ground Motion Dominant Frequency Effect on the Design of Multiple Tuned Mass Dampers, Journal of Earthquake Engineering, 8(1), 2004, 89-105. [11] Masri,S.F., Theory of the Dynamic Vibration Neutralizer with Motion Limiting Stops, Transactions of ASME, Journal of Applied Mechanics, 39, 1972, .563-568. [12] Calvi,G.M., Ceresa,P., Casarotti,C., Bolognini,D. and Auricchio,F., Effects of Axial Force Variation in the Seismic Response of Bridges Isolated with Friction Pendulum Systems, Journal of Earthquake Engineering, 8(Special Issue 1), 2004, 187- 224. [13] Wong,K.K.F., Seismic Energy Dissipation of Inelastic Structures with Tuned Mass Dampers, Journal of Engineering Mechanics, ASCE, 134(2), 2008, 163-172. [14] Aoki,S., Iwanami,K. and Sakakibara,K., Passive Control for Seismic Response of House with Oil Damper, Proceedings of International Conference on Instrumentation, Control and Information Technology (SICE Annual Conference 2008), Tokyo, 2008, pp.11733-1736. [15] Aoki,S., Kurita,K. and Yokoyama,Y., Reduction of Vibration of Structure using Oil Damper (Examination from Simulation Method), Proceedings of the 10th International Conference on Motion and Vibration Control, Tokyo, 2010, CD-ROM 1A13. [16] Iwanami,K., Development of Swing Type Damper with Attenuation Characteristic for Multi-dimension, Reports of Tokyo Metropolitan College of Technology, 41, 2005, pp.55-61.
  • 7. Shigeru Aoki, Katsumi Kurita / International Journal of Engineering Research and Applications (IJERA) ISSN: 2248-9622 www.ijera.com Vol. 3, Issue 4, Jul-Aug 2013, pp.2182-2188 2188 | P a g e