SlideShare a Scribd company logo
1 of 46
Download to read offline
USER’S GUIDE
ADAPTEC EMBEDDED SERIAL ATA RAID
ii
Copyright
© 2004 Adaptec, Inc. All rights reserved. No part of this publication may be
reproduced, stored in a retrieval system, or transmitted in any form or by any
means, electronic, mechanical, photocopying, recording or otherwise, without the
prior written consent of Adaptec, Inc., 691 South Milpitas Blvd., Milpitas, CA 95035.
Trademarks
Adaptec, the Adaptec logo, Adaptec Storage Manager, and HostRAID are
trademarks of Adaptec, Inc., which may be registered in some jurisdictions.
Windows 2000, Windows Server 2003, and Windows XP are trademarks of
Microsoft Corporation in the US and other countries, used under license.
All other trademarks are the property of their respective owners.
Changes
The material in this document is for information only and is subject to change
without notice. While reasonable efforts have been made in the preparation of this
document to assure its accuracy, Adaptec, Inc. assumes no liability resulting from
errors or omissions in this document, or from the use of the information contained
herein.
Adaptec reserves the right to make changes in the product design without
reservation and without notification to its users.
Disclaimer
IF THIS PRODUCT DIRECTS YOU TO COPY MATERIALS, YOU MUST HAVE
PERMISSION FROM THE COPYRIGHT OWNER OF THE MATERIALS TO AVOID
VIOLATING THE LAW WHICH COULD RESULT IN DAMAGES OR OTHER
REMEDIES.
iii
Contents
1 Introduction
Overview 1-1
What is HostRAID? 1-1
Operating System Compatibility 1-2
Storage Requirements 1-2
Features 1-2
Storage Management Software Overview 1-3
2 Installing the Driver
Installing the Driver in a New Windows System 2-2
Installing the Driver in an Existing Windows System 2-3
Installing Red Hat or SuSE Linux 2-3
Installing the Red Hat Driver in a New Linux System 2-3
Installing the SuSE Driver in a New Linux System 2-4
Installing or Updating the Driver in an Existing Red Hat
or SuSE Linux System 2-5
Installing the Netware Driver in a New NetWare System 2-6
Installing or updating device drivers after installing
NetWare 2-7
Updating the Device Drivers 2-7
Installing the Device Drivers 2-7
3 Installing and Starting Adaptec Storage Manager
Installing Storage Manager on Windows 3-2
Installing Storage Manager on Linux 3-3
Installing Storage Manager on NetWare 3-4
Starting Storage Manager 3-5
Logging into Remote Systems 3-5
iv
Contents
4 Understanding Adaptec Storage Manager
Introduction 4-1
Features 4-1
Overview 4-2
Physical Devices View 4-3
Logical Devices View 4-3
Changing How Drives are Displayed 4-4
Collapsed and Expanded Views 4-4
Component Views 4-5
5 Adaptec RAID Configuration Utility
Using the Array Configuration Utility 5-2
Managing Arrays 5-2
Creating Arrays 5-3
Add/Delete Hotspares 5-6
Initializing Disk Drives 5-6
Rebuilding Arrays 5-7
Verifying Drives 5-8
Using the Disk Utilities 5-8
Glossary
Index
1-1
1
Introduction
In this Chapter...
Overview
Adaptec Embedded Serial ATA RAID with HostRAID®
adds RAID
functionality to the Serial ATA I/O controller by supporting RAID
levels 0, 1, and 10.
What is HostRAID?
HostRAID adds entry level RAID support to the Serial ATA I/O
controller. With HostRAID, you can add reliable performance and
full data protection.
Overview 1-1
Operating System Compatibility 1-2
Storage Requirements 1-2
Features 1-2
Storage Management Software Overview 1-3
1-2
Introduction
Operating System Compatibility
Note: The HostRAID embedded software product supports
the following operating systems. However, depending on the
vendor and specific configuration of your system, it is
possible that only some of these operating systems are
supported. Consult your hardware vendor to clarify
operating system support.
s Microsoft®
Windows®
2000, Windows Server®
2003,
Windows XP, and IA-32
s Linux
s Red Hat Advanced Server 2.1 and 3.0
s SuSE SLES 8.0 and 8.2
s SuSE 9.0
s United Linux 1.0
s Miracle Linux 2.1
s Novell NetWare 6.5
Storage Requirements
Device drivers and storage management software require
approximately 20 MB of disk space.
Features
Adaptec Embedded Serial ATA RAID supports:
s RAID levels 0, 1, and 10 using Adaptec’s HostRAID technology.
s Operating system independent configuration and RAID
creation using Adaptec RAID Configuration (ARC).
s Easy array configuration and status using Adaptec Storage
Manager.
Install Adaptec Storage Manager as described in Chapter 3,
Installing and Starting Adaptec Storage Manager.
1-3
Introduction
s Hot swap rebuild of fault tolerant arrays through the operating
system.
s Event logging and broadcasting, including messaging for
alphanumeric pagers.
Storage Management Software Overview
Adaptec Embedded Serial ATA RAID includes the following
software tools to manage your storage subsystem:
s Adaptec Storage Manager—A storage management application
that provides you with an easy-to-use graphical interface to
manage your storage subsystem. For details, see Chapters 3
and 4.
s Adaptec RAID Configuration (ARC) Utility—Part of the
controller’s built-in BIOS code. You start ARC by pressing
Ctrl+A during BIOS startup. For details, see Chapter 5, Adaptec
RAID Configuration Utility.
s Array Configuration Utility (ACU)—A DOS/BIOS application
used to create, configure, and manage arrays. For details, see
Chapter 5, Adaptec RAID Configuration Utility.
Note: You must have the most recent versions of Adaptec
Storage Manager and ARC utility installed to run the Adaptec
Embedded SATA RAID drivers.
2-1
2
Installing the Driver
In this Chapter...
This chapter describes installing the driver and setting up the new
array for the drives attached to your controller. Before you get
started, you need to select from the following scenarios for
installing the controller driver on Windows, Linux, or NetWare
systems:
s Installing the Driver in a New Windows System on page 2-2
s Installing the Driver in an Existing Windows System on page 2-3
s Installing Red Hat or SuSE Linux on page 2-3
s Installing the Netware Driver in a New NetWare System on
page 2-6
s Installing or updating device drivers after installing NetWare on
page 2-7
Note: You must have the most recent versions of Adaptec
Storage Manager and ARC utility installed to run the Adaptec
Embedded SATA RAID drivers.
Installing the Driver in a New Windows System 2-2
Installing the Driver in an Existing Windows System 2-3
Installing Red Hat or SuSE Linux 2-3
Installing the Netware Driver in a New NetWare System 2-6
Installing or updating device drivers after installing NetWare 2-7
2-2
Installing the Driver
Installing the Driver in a New Windows System
In this scenario, you are installing the driver in a new system that
has no operating system. To install the driver:
1 Create a driver disk by following the instructions from the Web
site or the product CD.
2 Restart the computer.
3 If creating an array, press Ctrl+A when prompted to enter the
ARC utility. For instructions on creating an array from the BIOS,
see Chapter 5, Adaptec RAID Configuration Utility.
4 When the array is finished building, insert the Windows setup
CD and restart the system.
5 Press F6 when prompted to install a third-party driver.
Note: When F6 is active, a prompt appears at the bottom of
the screen. Press F6 immediately—you only have
5 seconds. If you miss your chance, restart this Windows
installation to complete it correctly. Otherwise, Windows
will not recognize your controller.
6 Insert the driver disk you created in Step 1 and wait until
prompted to install a driver.
7 Press S to specify that the driver is on the floppy disk, then
press Enter.
Windows searches the disk for a suitable driver.
8 When the Adaptec Embedded Serial ATA HostRAID driver is
found, press Enter. Follow the remaining on-screen instructions
to complete your installation.
2-3
Installing the Driver
Installing the Driver in an Existing Windows
System
In this scenario, you are installing a driver in a system that already
has a Windows operating system. To install the driver:
1 Create a driver disk by following the instructions from the Web
site or the product CD.
2 Start Windows. Windows launches the Found New Hardware
Wizard, which searches for the controller driver.
3 Insert the driver disk you created in Step 1, select the floppy
disk drive as the source then click Next.
4 If necessary, select the appropriate driver for your operating
system.
5 Click Next as needed to complete the controller installation.
6 Remove the driver disk.
7 If prompted, restart the computer.
8 Your installation is complete. If you want to create an array
from the BIOS, see Chapter 5, Adaptec RAID Configuration
Utility. If you want to create an array from the operating
system, see Chapter 4, Understanding Adaptec Storage Manager.
Installing Red Hat or SuSE Linux
Installing the Red Hat Driver in a New Linux System
In this scenario, you are installing the driver in a new Red Hat
Linux system. To install the driver:
1 Create a driver disk by following the instructions from the Web
site or the product CD.
2 Restart the computer.
3 If creating an array, press Ctrl+A when prompted to enter the
ARC utility. For instructions on creating an array from the BIOS,
see Chapter 5, Adaptec RAID Configuration Utility.
4 When the array is finished building, insert the Red Hat CD
Disk 1 in the CD-ROM drive then restart the system.
2-4
Installing the Driver
5 When the Red Hat Welcome screen appears, type expert or
linux dd at the boot prompt.
6 When prompted, insert the driver disk (see Step 1) then select
OK.
7 Follow the prompts to set up your preferred environment.
8 If you intend to install other third-party devices, proceed with
the installation of those devices. Otherwise, select Done.
9 Continue with the Linux installation according to the Red Hat
documentation.
Installing the SuSE Driver in a New Linux System
In this scenario, you are installing the driver in a new SuSE Linux
system. To install the driver:
1 Create a driver disk by following the instructions from the Web
site or the product CD.
2 Restart the computer.
3 If creating an array, press Ctrl+A when prompted to enter the
ARC utility. For instructions on creating an array from the BIOS,
see Chapter 5, Adaptec RAID Configuration Utility.
4 When the array is finished building, insert the SuSE CD Disk 1
in the CD-ROM drive then restart the system.
5 When the SuSE Installation menu appears, press the F3 key,
then select installation option from the Menu then press Enter.
6 When prompted, insert the driver disk you created (see Step 1)
then press any key to continue.
7 Follow the prompts to set up your preferred environment.
8 Continue with the Linux installation according to the SuSE
documentation.
2-5
Installing the Driver
Installing or Updating the Driver in an Existing Red Hat or SuSE
Linux System
To install the driver in an existing Red Hat or SuSE Linux system:
If Driver Files Are On A Web Site
1 Create an rpm diskette for your Linux distribution and version.
2 Insert the rpm diskette into the floppy diskette drive then open
up a command shell. From the shell type:
mount /dev/fd0 /mnt/floppy
cd /mnt/floppy
rpm -ivh <rpmfile> (for a new install, or)
rpm -Uvh --force <rpmfile> (for an updated install)
3 Reboot the system to enable the new/updated driver.
If Driver Files Are On The Product CD
1 Insert the driver CD into the CD device and wait for the system
to automount the cd, or manually mount it from a shell by
typing:
mount /dev/cdrom /mnt/cdrom
2 Then type:
cd /<directory of rpm files>
3 Type:
rpm -ivh <rpmfile> (for a new install, or)
rpm -Uvh --force <rpmfile> (for an updated install)
cd
umount /mnt/cdrom
or
eject (to eject disc)
4 Reboot the system to enable the new/updated driver.
2-6
Installing the Driver
Installing the Netware Driver in a New NetWare
System
Note: For information about installing drivers if you use the
NetWare CD to install your operating system, see your
Novell documentation.
Use these steps to install the driver in a new Novell NetWare 6.5
system. To install the driver:
1 Use the instructions provided in the NetWare manual to begin
the installation.
2 When the Choose the Server Drivers - Disk Driver prompt appears
during the installation process, select Storage adapters; then,
press Enter.
3 If the list contains the HostRAID SATA driver (AARICH.HAM) or
(AAR81XX.HAM), select the driver then press the Delete key to
delete it.
4 Press the Insert key twice to Add an unlisted driver.
5 Insert the support diskette for Novell NetWare.
6 Press F3 to specify a path then type a: (where a is the diskette
drive letter) then press Enter.
Note: The driver and support files will be copied to the
system volume: either AARICH.HAM or AAR81XX.HAM.
7 Verify that the driver name displays in the list of device drivers
that appears in the window (for example, AARICH.HAM) then
select Return to Driver Summary then press Enter.
8 Select Continue then press Enter.
9 Follow the instructions in the NetWare manual to complete the
installation.
2-7
Installing the Driver
Installing or updating device drivers after
installing NetWare
To update the driver in an existing NetWare 6.5 system see
Updating the Device Drivers. To install the driver in an existing
NetWare system, see Installing the Device Drivers.
Updating the Device Drivers
1 From the system console, type the following and press Enter
then:
Unload driver_name
where
driver_name is AARICH or AAR81XX
For example:
Unload AARICH
2 Do not restart the system; continue with the instructions for
Installing the Device Drivers.
Installing the Device Drivers
1 Start the NetWare hdetect utility program. From the system
console, type the following then press Enter:
load hdetect
2 Insert the HostRAID support diskette for Novell NetWare into
the floppy diskette drive.
3 When you see the prompt Sys volume not mounted. Load driver
anyway?, select Yes then press Enter to continue.
4 The device driver window opens, showing a list of storage
adapters. Select Modify.
5 Press Enter to continue then select Modify.
6 Select the driver then press the Delete key to delete it.
7 When the next window opens, press the Insert key twice to add
a driver.
2-8
Installing the Driver
8 When the next window opens, press F3 to specify a different
path.
9 In the Specify a directory path field, type a: (where a is the
diskette drive letter) then press Enter.
10 After the installation program copies all the files, press Esc to
exit the hdetect utility.
Note: If you want NetWare to load the HostRAID device
driver automatically during startup, you must add the
appropriate LOAD command to the NetWare startup
command file (usually C:NWSERVERSTARTUP.NCF). The
command has the form:
load [pathname]driverslot=number [options]
For example:
load c:nwservera320raid.ham slot=1
3-1
3
Installing and Starting
Adaptec Storage Manager
In this Chapter...
After you have installed your Adaptec RAID controller and driver,
you are ready to install and use Adaptec Storage Manager—a
user-friendly graphical user interface (GUI) that makes it easy for
you to create and manage arrays without having to restart the
computer and use the BIOS utility.
Note: You need administrator or root privileges to install
Storage Manager. For details on verifying privileges, refer to
your operating system documentation.
Installing Storage Manager on Windows 3-2
Installing Storage Manager on Linux 3-3
Installing Storage Manager on NetWare 3-4
Starting Storage Manager 3-5
Logging into Remote Systems 3-5
3-2
Installing and Starting Adaptec Storage Manager
Installing Storage Manager on Windows
This section provides instructions for installing Storage Manager.
Note: On Windows, Storage Manager supports up to 16
Adaptec RAID controllers.
To install Storage Manager:
1 Insert the product installation CD and wait for the Autorun
executable to start the installation. If this does not occur, browse
the CD and click Autorun.
2 When the installation wizard starts, follow the instructions on
the screen to complete the installation.
Note: When prompted to install SNMP (Simple Network
Management Protocol), accept the default (do not install)
unless you have a specific requirement for Storage Manager
to work with SNMP gets and traps.
3-3
Installing and Starting Adaptec Storage Manager
Installing Storage Manager on Linux
Notes:
s With Linux, Storage Manager supports up to 12 Adaptec
RAID controllers.
s Storage Manager includes the Java Runtime Environment
(JRE).
s If a previous version of Storage Manager is already
installed and you are upgrading, you must first remove
that version. Any customization files you may have
created when you used the previous version are saved and
used in the upgrade. To remove Storage Manager, type the
rpm --erase StorMan command.
s For the latest on Adaptec’s support of Linux, visit
www.adaptec.com.
To install Storage Manager:
1 Insert the product installation CD.
2 Mount the product installation CD:
3 Change to the cdrom directory:
4 Extract the RPM package and install it:
rpm --install ./StorMan*.rpm
5 Unmount the product installation CD:
for Red Hat mount /dev/cdrom /mnt/cdrom
for SuSE mount /dev/cdrom /media/cdrom
for Red Hat cd /mnt/cdrom/linux/manager
for SuSE cd /media/cdrom/linux/manager
for Red Hat umount /mnt/cdrom
for SuSE umount /media/cdrom
3-4
Installing and Starting Adaptec Storage Manager
Installing Storage Manager on NetWare
Notes:
s With NetWare, Storage Manager supports up to 16
Adaptec RAID controllers.
s You need the latest Support Pack for your operating system
so you can run the supported Java Virtual Machine (JVM).
s You need JVM version 1.3 or later. To check your JVM
version, load JVM, type JAVA -VERSION.
s For the latest updates from Novell, visit www.novell.com.
To install Storage Manager:
1 Insert the product installation CD.
2 From the command prompt, type load cdrom then press Enter.
3 From the command prompt, type:
RaidMan:netwaremanagerinstall
The installation program starts.
4 Follow the instructions on the screen to complete the
installation.
3-5
Installing and Starting Adaptec Storage Manager
Starting Storage Manager
Note: You need root privileges to run Storage Manager.
To start Storage Manager, use the procedure outlined in the table
below for your operating system.
Logging into Remote Systems
To log into a remote system:
1 Click Remote > Add Remote System.
Storage Manager displays the login screen, as shown below.
Ifyouroperating
system is... Start Storage Manager as follows...
Windows To run Storage Manager as a standalone application,
click Start > Programs > Adaptec Storage Manager,
then select the appropriate icon.
Linux Change to the directory where you installed Storage
Manager by typing cd /usr/RaidMan then use the
sh RaidMan.sh shell command.
NetWare Type the LOAD RAIDMAN command.
3-6
Installing and Starting Adaptec Storage Manager
2 Type the IP address.
The default System startup port number, 34571, is supplied for
you.
3 For Username, type admin
4 For Password, type adaptec
Note: The username and password are case sensitive.
Once you are logged in for the first time, you can add new accounts
and change account passwords. For details, refer to the online
Help.
4-1
4
Understanding Adaptec
Storage Manager
In this Chapter...
Introduction
This chapter provides an overview of Adaptec Storage Manager,
the user-friendly GUI that you use to easily create and manage
arrays. For more details on using Adaptec Storage Manager to set
up and manage arrays, refer to the online Help.
Features
You can use Adaptec Storage Manager to:
s Create and delete arrays
s Verify arrays
s Migrate arrays
s Add and remove hotspares
s Change RAID level
Introduction 4-1
Overview 4-2
Changing How Drives are Displayed 4-4
Collapsed and Expanded Views 4-4
Component Views 4-5
4-2
Understanding Adaptec Storage Manager
s View the RAID configuration
s View information about managed systems and subsystems
such as arrays, logical drives, hot-spare drives, physical drives
s Notify systems of all events occurring on the local system
s Increase logical device size
s Manage scheduled tasks such as Verify or Migrate
s Add or remove a remote system
s Configure, administer, and monitor controllers that are
installed locally or remotely in your servers or external storage
s Fine tune controller settings for optimal performance
Note: Some of these features may not be available on your
system. Check with your vendor, product documentation, or
online Help for supported features.
Overview
Adaptec Storage Manager provides an expandable tree view of the
systems and controllers you are managing. You can perform most
configuration and management tasks by selecting a controller from
the tree and working with related objects. The figure below shows
how Adaptec Storage Manager displays information about Physical
and Logical devices.
4-3
Understanding Adaptec Storage Manager
Using the buttons in the Physical devices and Logical devices
views, you can:
s Change how drives are displayed.
s Collapse and expand a view.
s Identify components of a logical device.
s Create and delete hotspares.
Physical Devices View
This view displays information about the drives, enclosures, and
other physical devices attached to the controller. The devices are
organized numerically. The display for each channel or port
includes information on maximum speed, the number of the
channels on the controller, and the number of devices attached to
the controller.
Indicators, next to the controller name, report status of the fan and
temperature modules on SAF-TE (enclosure management) devices and
other devices that monitor these conditions. The indicator colors are:
s Blue—Normal
s Yellow—Warning
s Red—Error
s Gray—Not applicable to the devices.
For example, the fan indicator changes to yellow when one fan
fails; it changes to red when a second fan fails and cooling is no
longer adequate.
Logical Devices View
This view displays information about the logical devices created
using the physical devices, including the number of logical devices,
the RAID level of each device, and whether a logical device is
protected by a hotspare.
You can create and delete logical devices in the Logical devices
view by selecting the Create option and using the Create wizard.
4-4
Understanding Adaptec Storage Manager
Changing How Drives are Displayed
You can choose how information is displayed in the Physical
devices view by clicking one of the following buttons in the Logical
devices view.
Collapsed and Expanded Views
You can display a collapsed or expanded view of the system
configuration. Initially, Storage Manager displays a collapsed
textual view of the configuration information in both the Logical
devices and Physical devices views.
Displays physical device information in text format. This is the
default view.
Displays physical device information in full size capacity format.
A full-length bar is displayed for each drive, regardless of
capacity. A small segment on each drive is reserved for the RAID
signature; this area is indicated by a gray cap at the end of each bar.
Note: A drive shaded in light blue is not part of any disk group.
Displays physical device information in relative size capacity
format. A full-length bar is displayed for the largest drive;
proportionally shorter bars are displayed for other drives.
In the Logical devices view...
Click to expand and collapse information about disk groups and
logical devices. The expanded display shows the following
information about each logical device:
s Disk group name and capacity (if available)
s Logical device size
s Logical device state
s Build progress
In the Physical devices view...
Click to expand and collapse information about physical drives.
The expanded display shows the following information about
each drive:
s Capacity of the drive
s Drive ID
s Drive state
4-5
Understanding Adaptec Storage Manager
Component Views
When you click a physical or logical device in the device views, the
related components are highlighted in the other view.
s When you click a logical device in the Logical devices view, the
physical drives that make up the logical device are highlighted
in the Physical devices view, and vice-versa.
s When you click a hotspare, the logical devices protected by that
spare are highlighted.
s In the graphical views, if the logical device uses only part of the
available storage, only those segments are highlighted (in dark
blue).
5-1
5
Adaptec RAID
Configuration Utility
In this Chapter...
The Adaptec RAID Configuration (ARC) utility is an embedded
BIOS utility that includes:
s Array Configuration Utility (ACU)—Used to create, configure,
and manage arrays.
s Disk Utilities—Used to format or verify disks.
To run ARC, press Ctrl+A when prompted by the following
message during the system startup:
Press <Ctrl><A> for Adaptec RAID Configuration Utility
The ARC menu appears, presenting these options:
s Array Configuration Utility (ACU)
s Disk utilities
To select an option from this menu, or from any of the menus
within ARC, browse with the arrow keys, then press Enter. In some
cases, selecting an options displays another menu. To return to the
previous menu at any time, press Esc.
Using the Array Configuration Utility 5-2
Using the Disk Utilities 5-8
5-2
Adaptec RAID Configuration Utility
Using the Array Configuration Utility
The Array Configuration Utility (ACU) enables you to create,
manage, and delete arrays from the controller’s BIOS, add and
delete spare drives, and initialize drives.
Managing Arrays
Select the Manage Arrays option to view array properties and
members, and delete arrays. The following sections describe these
operations in greater detail.
Viewing Array Properties
To view the properties of an existing array:
1 At the BIOS prompt, press Ctrl+A.
2 From the ARC menu, select Array Configuration Utility
(ACU).
3 From the ACU menu, select Manage Arrays.
4 From the List of Arrays dialog box, select the array you want to
view then press Enter.
The Array Properties dialog box appears, showing detailed
information on the array. The physical disks associated with the
array are displayed here.
5 Press Esc to return to the previous menu.
Deleting Arrays
Caution: Back up the data on an array before you delete it.
Otherwise, all data on the array is lost. Deleted arrays cannot
be restored.
To delete an existing array:
1 Turn on your computer and press Ctrl+A when prompted to
access the ARC utility.
2 From the ARC menu, select Array Configuration Utility
(ACU).
3 From the ACU menu, select Manage Arrays.
!
5-3
Adaptec RAID Configuration Utility
4 Select the array you wish to delete then press Delete.
5 In the Array Properties dialog box, select Delete then press
Enter. The following prompt is displayed:
Warning!! Deleting the array will render array unusable. Do you want to
delete the array?(Yes/No):
6 If you press Yes, select the member when the following prompt
is displayed:
To delete the partition table, choose which member:
member #0, member #1, both, none
7 Press Esc to return to the previous menu.
Creating Arrays
Before creating arrays, make sure the disks for the array are
connected and installed in your system. Note that disks with no
usable space are shown in gray and cannot be used. See Initializing
Disk Drives on page 5-6.
To create an array:
1 Turn on your computer and press Ctrl+A when prompted to
access the ARC utility.
2 From the ARC menu, select Array Configuration Utility
(ACU).
3 From the ACU menu, select Create Array.
4 Select the disks for the new array then press Insert. To deselect
any disk, highlight the disk then press Delete.
5 Press Enter when both disks for the new array are selected. The
Array Properties menu displays.
Assigning Array Properties
Note: Once the array is created and its properties are assigned,
you cannot change the array properties using the ACU.
Instead, use Adaptec Storage Manager (See Chapter 4 for
details.)
5-4
Adaptec RAID Configuration Utility
To assign properties to the new array:
1 In the Array Properties menu, select an array type then press
Enter. Note that only the available array types, RAID 0, RAID 1
and RAID 10 are displayed. RAID 0 and RAID 1 requires two
drives. RAID 10 requires four drives.
2 Type in an optional label of no more than 15 characters for the
array, then press Enter.
3 For RAID 0, select the desired stripe size. Available stripe sizes
are 16, 32, and 64 KB (default).
Note: Adaptec recommends that you do not change the
default.
4 The options under Create Using allows you to select between
the different creation methods for RAID 0, RAID 1, and RAID
10. The following table gives examples of when each is
appropriate.
RAID
Level
Create
Using When Appropriate
RAID 0 No Init Creating a RAID 0 on new drives.
RAID 0 Migrate1
1
If you select Migrate for RAID 0 or Build for RAID 1 or RAID 10, you will be asked to
select the source drive. The contents of the source drive will be preserved. However,
the data on the new drive will be lost.
Creating a RAID 0 from one new drive and
one drive with data you wish to preserve.
RAID 1 Build1 Any time you wish to create a RAID 1, but
especially if you have data on one drive that
you wish to preserve.
RAID 1
RAID 10
Clear Creating a RAID 1 or RAID 10 on new
drives, or when you want to ensure that the
array contains no data after creation.
RAID 1
RAID 10
Quick
Init
Fastest way to create a RAID 1or RAID 10.
Appropriate when using new drives.
5-5
Adaptec RAID Configuration Utility
Notes:
s Before adding a new drive to an array, back up any data
contained on the new drive. Otherwise, all data will be lost.
s If you stop the Build or Clear process on a RAID 1 or RAID
10 from ACU, you can restart it by pressing Ctrl+R.
s A RAID 1 created using the Quick Init option may return
some data miscompares if you later run a consistency check.
This is normal and is not a cause for concern.
s The ACU allows you to use drives of different sizes in a
RAID 1 or RAID 10. However, during a build operation ,
only the smaller drive can be selected as the source or first
drive.
s When migrating from single volume to RAID 0, migrating
from a larger drive to a smaller drive is allowed. However,
the destination drive must be at least half the capacity of the
source drive.
s Adaptec does not recommend that you migrate or build an
array on Windows dynamic disks (volumes), as it will result
in data loss.
Caution: Do not interrupt the creation of a RAID 0 using the
Migrate option. If you do, there is no way to restart, and
no way to recover the data that was on the source drive.
5 When you are finished, press Done.
Adding/Removing a Bootable Array
To make an array bootable:
1 From the Main menu, select Manage Arrays.
2 From the List of Arrays, select the array you want to make
bootable, then press Ctrl+B. An asterisk will appear next to the
bootable array.
3 To make the array nonbootable, select it then press Ctrl+B. The
asterisk will disappear next to the array indicating that it is
nonbootable.
!
5-6
Adaptec RAID Configuration Utility
Add/Delete Hotspares
Select the Add/Delete Hotspares option to add, delete, or view hot
spares.
1 Turn on your computer and press Ctrl+A when prompted to
access the ARC utility.
2 From the ARC menu, select Array Configuration Utility
(ACU).
3 From the ACU menu, select Add/Delete Hotspares.
4 Use the up and down arrow keys to highlight the disk you want
to designate as a Hotspare, then press Insert>Enter.
5 Press Yes when the following prompt is displayed:
Do you want to create spare? (Yes/No)
The Spare you have selected will appear in the Selected Drive
menu.
Initializing Disk Drives
Caution: If the drive is used in an array, you may not be able to
use the array again. Do not initialize a disk that is part of a
boot array. To determine which disks are associated with a
particular array, see Viewing Array Properties on page 5-2.
To initialize drives:
1 Turn on your computer and press Ctrl+A when prompted to
access the ARC utility.
2 From the ARC menu, select Array Configuration Utility
(ACU).
3 Select Initialize Drives.
4 Use the up and down arrow keys to highlight the disk you wish
to initialize then press Insert.
5 Repeat Step 4 if you want to add another drive to be initialized.
6 Press Enter.
!
5-7
Adaptec RAID Configuration Utility
7 Read the warning message and ensure that you have selected
the correct disk drives to initialize. Type Y to continue.
Rebuilding Arrays
Note: Rebuilding applies to Fault Tolerant arrays (RAID 1 and
RAID 10) only.
By replacing a failed disk of a RAID 1 or RAID 10 array with a new
disk, you can Rebuild to get the array to Optimal status and
assume fault tolerance. You can perform a Rebuild in the following
ways:
Note: If no spare exists and a hard disk drive fails, you need to
create a spare before you can rebuild an array. See Add/Delete
Hotspares on page 5-6 before continuing your Rebuild.
System Shutdown Rebuild
You can shutdown the system and replace the failed disk with a
new one (of equal or greater capacity). Once the system is booted, a
new drive can be assigned as the spare drive, and this will start the
Rebuild task. All the data from the good disk is copied to the new
one, and the original RAID 1 or RAID 10 array is recreated.
Manual Rebuild
1 From the Main Menu, select Manage Arrays. From the List of
Arrays, select the array you want to Rebuild.
2 Press Ctrl+R to Rebuild.
5-8
Adaptec RAID Configuration Utility
Verifying Drives
If you are notified of a mismatch of data during a build of RAID 1
or RAID 10, you have an option of verifying your drives. To Verify
the drives:
Note: You will only have the Verify option available if the
array is Optimal. If the array has failed, you will need to
rebuild the array.
1 Select the drives you need to verify.
2 Press Ctrl+S.
3 When the Verify is complete, you will be notified with any
errors found during the Verify operation.
Using the Disk Utilities
The Disk Utilities enable you to format or verify the media of your
Serial ATA hard disks.
To access the disk utilities:
1 Turn on your computer and press Ctrl+A when prompted to
access the ARC utility.
2 From the ARC menu, select Disk Utilities.
3 Select the desired disk then press Enter.
You are offered the following options:
s Format Disk—Simulates a low-level format of the hard
drive by writing zeros to the entire disk. Serial ATA drives
are low-level formatted at the factory and do not need to be
low-level formatted again.
Caution: Formatting destroys all data on the drive. Be
sure to back up your data before performing this
operation.
s Verify Disk Media—Scans the media of a disk drive for
defects.
!
Glossary-1
Glossary
A
activity
See task.
ACU
Array Configuration Utility. An application used to create,
configure, and manage arrays from the controller’s BIOS or
MS-DOS.
array
A logical disk created from available space and made up of one or
more segments on one or more physical disks. Arrays are typically
used to provide data redundancy or enhanced I/O performance.
See also volume, spanned volume, RAID 0, RAID 1. Also known as a
container.
array initialization
See initialize.
ATA
AT Bus Attachment. Standard parallel interface to IDE hard disks
typically used in desktop computers and some entry-level servers.
Serial ATA (SATA), is a successor to parallel ATA, which is
sometimes referred to as PATA.
available space/segment
Unused space on an initialized disk from which logical devices
(arrays) are created. When an array is deleted, the space that it used
is returned to the available space pool.
Glossary-2
Glossary
B
background consistency check
Option that forces the controller to constantly check all portions of
disks used by all arrays to see if the disks can return data from the
blocks. See also consistency check command.
bad segment
Segment that is in an unknown state.
bootable array
Array configured as the boot device.
build
Background initialization of a redundant array. The array is
accessible throughout. RAID 1 copies the contents of the primary
drive to a secondary drive. See also clear.
bus
See channel.
C
cache
Fast-access memory on the controller that serves as intermediate
storage for data that is read from, or written to, drives.
capacity
Total usable space available in megabytes or gigabytes.
channel
Any path, or bus, used for the transfer of data and the control of
information between storage devices and a RAID controller. For
SATA channels, each channel has a single drive capacity.
Glossary-3
Glossary
check point
A feature that enables you to exit the ACU when an operation is in
progress and be able to continue without interruption. The driver
then resumes the operation from where the BIOS left off and the
BIOS resumes the operation where the driver left off.
chunk
See stripe.
clear
Foreground initialization of a fault-tolerant array. A clear operation
zeros all blocks of the array. The array is not accessible until the
clear task is complete.
concatenation
Joining of physical or logical drives in sequential order.
consistency check command
Command that reads all the blocks of a RAID 1 to determine if the
blocks are consistent. Any inconsistent blocks are fixed.
D
dead partition
See failed.
degraded
A redundant (for example, a RAID 1) array in which one or more
members have failed. The data is intact but redundancy has been
compromised. Any further failure would cause the array to fail and
result in data loss.
disk
Physical disk drive. Randomly accessible, rewritable data storage
device. Also called hard disk.
disk ID
Unique disk identifier that consists of the channel number, SATA
ID. For example, (channel:ID:LUN) 1:04:0. See also channel.
Glossary-4
Glossary
drive LED
Disk indicator LED that illuminates during read or write
operations.
E
event
Notification or alert from the system, indicating that a change has
occurred.
event log
File used to maintain information about prior controller activities
or errors.
event notification
Process for transmitting events.
F
failed
State of a nonredundant array that has suffered a single drive
failure, or a redundant array that has suffered multiple drive
failures. A failed array is inaccessible and data is lost.
fault-tolerant array
Refers to an array that can continue to function after a disk drive
failure without loss of data. Fault tolerant, or redundant arrays,
include RAID 1 arrays. See also Redundant.
foreign disk
Disk that has previously been initialized on another Adaptec RAID
controller. The RAID signature on the disk allows the RAID
controller to identify whether or not the disk was initialized on the
controller it is currently connected to.
Glossary-5
Glossary
H
hard disk drive
Basic unit of nonvolatile, nonremovable, magnetic storage media.
See also disk.
hot swap
To remove a component from a system, and install a new
component while the power is on and the system is running.
hotspare
A spare hard disk that automatically replaces a failed hard disk on
any array associated with any HBA.
I
impacted
An impacted array is one which has been created but for some
reason the initial build operation did not complete. All member
drives are present and operational, and all data written to the array
is protected. To optimize the array, run a Verify with Fix Task.
initialize
Process of preparing a disk for use by the controller. When a disk is
initialized, the controller records the RAID signature on the disk.
initialized array
An array that is ready for data reads and writes. Arrays can be
initialized by build or clear.
L
legacy disk
Disk that contained a valid partition table when connected to the
controller. The controller manages the disk as a legacy disk array
where there is a one-to-one logical-to-physical mapping of array to
disk.
Glossary-6
Glossary
logical device
Volume comprised of space from one or more physical drives and
presented to the operating system as if it were a single storage unit.
low-level format
Process performed by the drive firmware that completely cleans
any data off the hard disk.
M
mirrored array/mirroring
See RAID 1.
monitoring
Process of receiving, displaying, and logging system events.
O
offline array
Array that can no longer be accessed.
optimal
The state of an array when it is fully operational. For redundant
arrays, the entire array is protected.
P
partition
A section of a disk storage device created by the operating system
disk management program, in which data and/or software
programs are stored. Computers have a primary operating system
partition that contains the special files needed to boot the
computer. Each operating system partition is assigned a unique
drive letter, such as C or D. A single disk device can have multiple
partitions.
phantom object
Object that represents a component that cannot be configured by
the controller management software; for example, a missing drive.
Glossary-7
Glossary
Q
quick init
An array initialized using the Quick Init option is available
immediately, with no on-going background controller activity. All
data written to an array that has been quick initialized is protected.
R
RAID
Redundant Array of Independent Disks (alternative definition
Redundant Array of Inexpensive Disks).
RAID 0
A single-level array consisting of two or more equal-sized segments
residing on different disks. RAID 0 distributes data evenly across
its respective drives in equal-sized sections called stripes. RAID 0
arrays are not redundant.
RAID 1
Single-level array consisting of two equal segments residing on
two different drives. Provides redundancy by storing identical
copies on two drives.
See also mirrored array/mirroring.
RAID signature
The area on each disk reserved for use by the RAID controller.
RAID volume
Concatenates two or more arrays of the same type.
rebuild
Background regeneration of redundant data on a RAID 1.
redundant
The ability of an array to maintain operability when one or more
hardware failures occur. RAID 1 is redundant. In the event of a
drive failure, redundant arrays can be restored to normal operation
by replacing the failed drive and rebuilding the array.
Glossary-8
Glossary
rescan
Process of updating the current screen to show all currently
available resources.
S
Serial ATA (SATA)
A successor to ATA that uses a serial, instead of parallel, interface.
simple volume
A volume made up of disk space from a single disk. It can consist
of a single region on a disk, or concatenated multiple regions of the
same disk.
single-level array
Array created from one or more segments. See also volume, spanned
volume, RAID 0, RAID 1.
snapshot
Instantaneous read-only copy of an array at a precise point in time.
spanned volume
A simple volume that spans two or more drives.
stripe
Contiguous set of data distributed across all the disks in an array. A
striped array distributes data evenly across all members in equal-
sized sections called stripes.
stripe size
The amount of data in each section of a striped array.
striped array
See RAID 0.
Glossary-9
Glossary
T
task
An operation that occurs only on the RAID controller,
asynchronous to all other operations; for example, initializing a
disk or verifying an array. Some tasks can take an extended period
of time, particularly if the RAID controller is also performing
intensive data I/O while the task is running.
V
verify
Low-level check that a drive, logical device, or hot spare is good. In
a RAID 1, verify is a low-level check that contents of both
members’ segments are consistent and, optionally, corrects errors
while assuming that the master drive is correct. In a simple
volume, verify performs a low-level check that the whole drive can
be read.
volume
See simple volume, spanned volume.
Index-1
Index
A
ACU
overview 1-3
using to manage arrays 5-2
Adaptec RAID Configuration
utility
overview 1-3
Adaptec Storage componet views
4-5
Adaptec Storage Manager
features 4-1
logical devices view 4-3
overview 1-3, 4-2
physical devices view 4-3
Array Configuration Utility.
See ACU
Array Properties dialog box
deleting arrays 5-3
Arrays
creating bootable arrays 5-2
arrays
stripe size 5-4
B
Bootable arrays
creating 5-2
C
Caching
read 5-4
Containers
creating with CCU 5-3
deleting 5-2
managing with CCU 5-2
D
device drivers
installing
NetWare 2-7
updating
NetWare 2-7
Disk Size Advisory 5-2
Disks
initializing 5-6
size advisory 5-2
driver installation
installing in existing Linux
system 2-5
installing in existing NetWare
system 2-7
installing in existing Windows
system 2-3
installing in new Linux system
2-3
installing in new NetWare
system 2-6
installing in new Windows
system 2-2
F
features 1-2
Format disk 5-8
H
HostRAID
overview 1-1
I
Initializing Disks 5-6
initializing drives 5-6
installing NetWare driver 2-6
Index-2
Index
L
Linux driver installation
in existing system 2-5
in new system 2-3
M
Manage Arrays option 5-2
N
NetWare
device drivers 2-7
NetWare driver installation 2-6
O
operating system compatibility
1-2
R
Read caching 5-4
Rebuilding arrays 5-7
S
SCSI Disk Utilities 5-8
storage management
software overview 1-3
storage requirements 1-2
stripe size 5-4
V
Verify disk media 5-8
verifying drives 5-8
W
Windows driver installation
in existing system 2-3
in new system 2-2
R
Adaptec, Inc.
691 South Milpitas Boulevard
Milpitas, CA 95035 USA
©2004 Adaptec, Inc.
All rights reserved. Adaptec and the Adaptec logo
are trademarks of Adaptec, Inc. which may be
registered in some jurisdictions.
Part Number: 513944-06, Ver. AA JG 07/04

More Related Content

What's hot

Checklist report vcs_6.0_solaris_11_x86-64
Checklist report vcs_6.0_solaris_11_x86-64Checklist report vcs_6.0_solaris_11_x86-64
Checklist report vcs_6.0_solaris_11_x86-64
mthukupally
 
Aix5[1].3+hacmp+oracle9 i+weblogic8.1安装实施报告
Aix5[1].3+hacmp+oracle9 i+weblogic8.1安装实施报告Aix5[1].3+hacmp+oracle9 i+weblogic8.1安装实施报告
Aix5[1].3+hacmp+oracle9 i+weblogic8.1安装实施报告
fm2008
 
Vsp 40 esxi_i_vc_setup_guide
Vsp 40 esxi_i_vc_setup_guideVsp 40 esxi_i_vc_setup_guide
Vsp 40 esxi_i_vc_setup_guide
bisratster
 
Akfiler12 upgrade advisor
Akfiler12 upgrade advisorAkfiler12 upgrade advisor
Akfiler12 upgrade advisor
Accenture
 
Configure raid on an hp server
Configure raid on an hp serverConfigure raid on an hp server
Configure raid on an hp server
Kamlesh Mishra
 

What's hot (19)

Checklist report vcs_6.0_solaris_11_x86-64
Checklist report vcs_6.0_solaris_11_x86-64Checklist report vcs_6.0_solaris_11_x86-64
Checklist report vcs_6.0_solaris_11_x86-64
 
Elastix installation
Elastix installationElastix installation
Elastix installation
 
Aix5[1].3+hacmp+oracle9 i+weblogic8.1安装实施报告
Aix5[1].3+hacmp+oracle9 i+weblogic8.1安装实施报告Aix5[1].3+hacmp+oracle9 i+weblogic8.1安装实施报告
Aix5[1].3+hacmp+oracle9 i+weblogic8.1安装实施报告
 
Esm rel notes_6.0cp1
Esm rel notes_6.0cp1Esm rel notes_6.0cp1
Esm rel notes_6.0cp1
 
Vsp 40 esxi_i_vc_setup_guide
Vsp 40 esxi_i_vc_setup_guideVsp 40 esxi_i_vc_setup_guide
Vsp 40 esxi_i_vc_setup_guide
 
Installation
InstallationInstallation
Installation
 
Fcm rapid-install-11122-1634210
Fcm rapid-install-11122-1634210Fcm rapid-install-11122-1634210
Fcm rapid-install-11122-1634210
 
Oracle ebs-r12-1-3installationlinux64bit
Oracle ebs-r12-1-3installationlinux64bitOracle ebs-r12-1-3installationlinux64bit
Oracle ebs-r12-1-3installationlinux64bit
 
Read me
Read meRead me
Read me
 
cynapspro endpoint data protection - installation guide
cynapspro endpoint data protection - installation guidecynapspro endpoint data protection - installation guide
cynapspro endpoint data protection - installation guide
 
Scientific Linux
Scientific LinuxScientific Linux
Scientific Linux
 
PCM600
PCM600PCM600
PCM600
 
Akfiler12 upgrade advisor
Akfiler12 upgrade advisorAkfiler12 upgrade advisor
Akfiler12 upgrade advisor
 
Configure HP Proliant DL360p - DL 380p Gen8 RAID
Configure HP Proliant DL360p - DL 380p Gen8 RAIDConfigure HP Proliant DL360p - DL 380p Gen8 RAID
Configure HP Proliant DL360p - DL 380p Gen8 RAID
 
Configure raid on an hp server
Configure raid on an hp serverConfigure raid on an hp server
Configure raid on an hp server
 
Oracle R12.1 Full & Tips Installation on Windows Server 2008 64/32 bit
Oracle R12.1 Full & Tips Installation on Windows Server 2008 64/32 bitOracle R12.1 Full & Tips Installation on Windows Server 2008 64/32 bit
Oracle R12.1 Full & Tips Installation on Windows Server 2008 64/32 bit
 
Vso nas
Vso nasVso nas
Vso nas
 
Silk Test Install Guide
Silk Test Install GuideSilk Test Install Guide
Silk Test Install Guide
 
Readme
ReadmeReadme
Readme
 

Viewers also liked

Mainul_Lindau Nobel Laureate Meeting
Mainul_Lindau Nobel Laureate MeetingMainul_Lindau Nobel Laureate Meeting
Mainul_Lindau Nobel Laureate Meeting
Mainul Hossain, Ph.D.
 
Towards reflective teaching
Towards reflective teachingTowards reflective teaching
Towards reflective teaching
Laura Palacio
 
2016-11-24-FCD Group Company profile
2016-11-24-FCD Group Company profile2016-11-24-FCD Group Company profile
2016-11-24-FCD Group Company profile
Binoy Kumar Das
 

Viewers also liked (17)

Mainul_Lindau Nobel Laureate Meeting
Mainul_Lindau Nobel Laureate MeetingMainul_Lindau Nobel Laureate Meeting
Mainul_Lindau Nobel Laureate Meeting
 
Towards reflective teaching
Towards reflective teachingTowards reflective teaching
Towards reflective teaching
 
Prevalencia de hipotiroidismo subclínico y su asociación con dislipidemia en ...
Prevalencia de hipotiroidismo subclínico y su asociación con dislipidemia en ...Prevalencia de hipotiroidismo subclínico y su asociación con dislipidemia en ...
Prevalencia de hipotiroidismo subclínico y su asociación con dislipidemia en ...
 
Search engine optimization and marketing
Search engine optimization and marketingSearch engine optimization and marketing
Search engine optimization and marketing
 
английский соNditional
английский соNditionalанглийский соNditional
английский соNditional
 
Moscas
MoscasMoscas
Moscas
 
Routine
RoutineRoutine
Routine
 
Prevalencia de síndrome metabólico (SM) en operadores de autobuses foráneos ...
Prevalencia de síndrome metabólico (SM) en operadores de autobuses foráneos  ...Prevalencia de síndrome metabólico (SM) en operadores de autobuses foráneos  ...
Prevalencia de síndrome metabólico (SM) en operadores de autobuses foráneos ...
 
Factores determinantes y cambios en las prevalencias de síndrome metabólico e...
Factores determinantes y cambios en las prevalencias de síndrome metabólico e...Factores determinantes y cambios en las prevalencias de síndrome metabólico e...
Factores determinantes y cambios en las prevalencias de síndrome metabólico e...
 
LinkedPro (US)
LinkedPro (US)LinkedPro (US)
LinkedPro (US)
 
2016-11-24-FCD Group Company profile
2016-11-24-FCD Group Company profile2016-11-24-FCD Group Company profile
2016-11-24-FCD Group Company profile
 
Variables sociodemográficas en pacientes con DM2 adscritos al módulo MIDE de ...
Variables sociodemográficas en pacientes con DM2 adscritos al módulo MIDE de ...Variables sociodemográficas en pacientes con DM2 adscritos al módulo MIDE de ...
Variables sociodemográficas en pacientes con DM2 adscritos al módulo MIDE de ...
 
Ondas eletromagneticas
Ondas eletromagneticasOndas eletromagneticas
Ondas eletromagneticas
 
Resume_PratikMotwani
Resume_PratikMotwaniResume_PratikMotwani
Resume_PratikMotwani
 
Active learning
Active learningActive learning
Active learning
 
Insighty z Google a strategia marki...
Insighty z Google a strategia marki...Insighty z Google a strategia marki...
Insighty z Google a strategia marki...
 
Solar Performance Monitoring
Solar Performance MonitoringSolar Performance Monitoring
Solar Performance Monitoring
 

Similar to M sata raid_adaptec

Safe peak installation guide version 2.1
Safe peak installation guide version 2.1Safe peak installation guide version 2.1
Safe peak installation guide version 2.1
Vladi Vexler
 
Sap ep 7.0 install
Sap ep 7.0 installSap ep 7.0 install
Sap ep 7.0 install
dkeerthan
 
SOP - 2013 Server Build
SOP - 2013 Server BuildSOP - 2013 Server Build
SOP - 2013 Server Build
Robert Jones
 
Netxms install guide
Netxms install guideNetxms install guide
Netxms install guide
Naga Raju N
 

Similar to M sata raid_adaptec (20)

Os installation in a raid or non raid system Supper micro
Os installation in a raid or non raid system Supper microOs installation in a raid or non raid system Supper micro
Os installation in a raid or non raid system Supper micro
 
Quick-Start Guide: Deploying Your Cloudian HyperStore Hybrid Storage Service
Quick-Start Guide: Deploying Your Cloudian HyperStore Hybrid Storage ServiceQuick-Start Guide: Deploying Your Cloudian HyperStore Hybrid Storage Service
Quick-Start Guide: Deploying Your Cloudian HyperStore Hybrid Storage Service
 
Guia instalacion SQL Server Denali
Guia instalacion SQL Server DenaliGuia instalacion SQL Server Denali
Guia instalacion SQL Server Denali
 
Safe peak installation guide version 2.1
Safe peak installation guide version 2.1Safe peak installation guide version 2.1
Safe peak installation guide version 2.1
 
Sap ep 7.0 install
Sap ep 7.0 installSap ep 7.0 install
Sap ep 7.0 install
 
Installing rhel 5
Installing rhel 5Installing rhel 5
Installing rhel 5
 
Dru lavigne servers-tutorial
Dru lavigne servers-tutorialDru lavigne servers-tutorial
Dru lavigne servers-tutorial
 
E56576 01
E56576 01E56576 01
E56576 01
 
Toad for my sql 6.3 installation guide
Toad for my sql 6.3 installation guideToad for my sql 6.3 installation guide
Toad for my sql 6.3 installation guide
 
Virtual box installation
Virtual box installationVirtual box installation
Virtual box installation
 
SOP - 2013 Server Build
SOP - 2013 Server BuildSOP - 2013 Server Build
SOP - 2013 Server Build
 
Netxms install guide
Netxms install guideNetxms install guide
Netxms install guide
 
All database solution-Installing Micosoft SQL Server 2016
All database solution-Installing Micosoft SQL Server 2016All database solution-Installing Micosoft SQL Server 2016
All database solution-Installing Micosoft SQL Server 2016
 
Hp storage
Hp storage Hp storage
Hp storage
 
The Unofficial VCAP / VCP VMware Study Guide
The Unofficial VCAP / VCP VMware Study GuideThe Unofficial VCAP / VCP VMware Study Guide
The Unofficial VCAP / VCP VMware Study Guide
 
Oracle database 12c client quick installation guide 5
Oracle database 12c client quick installation guide 5Oracle database 12c client quick installation guide 5
Oracle database 12c client quick installation guide 5
 
SAP BI 4.2_SP02_Server_on_SUSE_Linux
SAP BI 4.2_SP02_Server_on_SUSE_LinuxSAP BI 4.2_SP02_Server_on_SUSE_Linux
SAP BI 4.2_SP02_Server_on_SUSE_Linux
 
Gluster Storage Platform Installation Guide
Gluster Storage Platform Installation GuideGluster Storage Platform Installation Guide
Gluster Storage Platform Installation Guide
 
Fault tolerance ease of setup comparison: NEC hardware-based FT vs. software-...
Fault tolerance ease of setup comparison: NEC hardware-based FT vs. software-...Fault tolerance ease of setup comparison: NEC hardware-based FT vs. software-...
Fault tolerance ease of setup comparison: NEC hardware-based FT vs. software-...
 
Weblogic12 c installation guide
Weblogic12 c installation guideWeblogic12 c installation guide
Weblogic12 c installation guide
 

More from laonap166

More from laonap166 (20)

Huong dan xu ly cac loi khi su dung phan mem reset may in
Huong dan xu ly cac loi khi su dung phan mem reset may inHuong dan xu ly cac loi khi su dung phan mem reset may in
Huong dan xu ly cac loi khi su dung phan mem reset may in
 
Huong dan reset muc l200 epson
Huong dan reset muc l200 epsonHuong dan reset muc l200 epson
Huong dan reset muc l200 epson
 
NEC Server Documents
NEC Server DocumentsNEC Server Documents
NEC Server Documents
 
Mtcv giám đốc tt cntt
Mtcv giám đốc tt cnttMtcv giám đốc tt cntt
Mtcv giám đốc tt cntt
 
Nếu bạn làm it bạn cần biết
Nếu bạn làm it  bạn cần biếtNếu bạn làm it  bạn cần biết
Nếu bạn làm it bạn cần biết
 
Nhạp mon lap trinh khong code
Nhạp mon lap trinh khong code Nhạp mon lap trinh khong code
Nhạp mon lap trinh khong code
 
Ha active active bang gfs2
Ha active  active bang gfs2Ha active  active bang gfs2
Ha active active bang gfs2
 
Hướng dẫn cài đặt phần mềm turnoffmonitor
Hướng dẫn cài đặt phần mềm turnoffmonitorHướng dẫn cài đặt phần mềm turnoffmonitor
Hướng dẫn cài đặt phần mềm turnoffmonitor
 
Bao cao web cake php
Bao cao web cake phpBao cao web cake php
Bao cao web cake php
 
He 74 a-thltht-lãxuântâm-11tlt
He 74 a-thltht-lãxuântâm-11tltHe 74 a-thltht-lãxuântâm-11tlt
He 74 a-thltht-lãxuântâm-11tlt
 
Quản lý cua hang giai khat lxt
Quản lý cua hang giai khat lxtQuản lý cua hang giai khat lxt
Quản lý cua hang giai khat lxt
 
Ve ngoi nha lap trinh do hoa bang c
Ve ngoi nha lap trinh do hoa bang cVe ngoi nha lap trinh do hoa bang c
Ve ngoi nha lap trinh do hoa bang c
 
Don xin thanh lap doanh nghiep lien doanh
Don xin thanh lap doanh nghiep lien doanhDon xin thanh lap doanh nghiep lien doanh
Don xin thanh lap doanh nghiep lien doanh
 
Thu cam on khach hang
Thu cam on khach hangThu cam on khach hang
Thu cam on khach hang
 
Cai dat su_dung_acronis_snapdeployforpc_debungfilebackuphangloat
Cai dat su_dung_acronis_snapdeployforpc_debungfilebackuphangloatCai dat su_dung_acronis_snapdeployforpc_debungfilebackuphangloat
Cai dat su_dung_acronis_snapdeployforpc_debungfilebackuphangloat
 
Xd email server zimbra
Xd email server zimbraXd email server zimbra
Xd email server zimbra
 
Tom tat ly thuyet thi bằng lái xe b2
Tom tat ly thuyet thi bằng lái xe b2Tom tat ly thuyet thi bằng lái xe b2
Tom tat ly thuyet thi bằng lái xe b2
 
Policy Based Assignment DHCP – Windows Server 2012
Policy Based Assignment DHCP – Windows Server 2012Policy Based Assignment DHCP – Windows Server 2012
Policy Based Assignment DHCP – Windows Server 2012
 
How to backup active directory domain services database in windows server 201...
How to backup active directory domain services database in windows server 201...How to backup active directory domain services database in windows server 201...
How to backup active directory domain services database in windows server 201...
 
Dns backup and recovery in windows server 2012 r2
Dns backup and recovery in windows server 2012 r2Dns backup and recovery in windows server 2012 r2
Dns backup and recovery in windows server 2012 r2
 

M sata raid_adaptec

  • 2. ii Copyright © 2004 Adaptec, Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written consent of Adaptec, Inc., 691 South Milpitas Blvd., Milpitas, CA 95035. Trademarks Adaptec, the Adaptec logo, Adaptec Storage Manager, and HostRAID are trademarks of Adaptec, Inc., which may be registered in some jurisdictions. Windows 2000, Windows Server 2003, and Windows XP are trademarks of Microsoft Corporation in the US and other countries, used under license. All other trademarks are the property of their respective owners. Changes The material in this document is for information only and is subject to change without notice. While reasonable efforts have been made in the preparation of this document to assure its accuracy, Adaptec, Inc. assumes no liability resulting from errors or omissions in this document, or from the use of the information contained herein. Adaptec reserves the right to make changes in the product design without reservation and without notification to its users. Disclaimer IF THIS PRODUCT DIRECTS YOU TO COPY MATERIALS, YOU MUST HAVE PERMISSION FROM THE COPYRIGHT OWNER OF THE MATERIALS TO AVOID VIOLATING THE LAW WHICH COULD RESULT IN DAMAGES OR OTHER REMEDIES.
  • 3. iii Contents 1 Introduction Overview 1-1 What is HostRAID? 1-1 Operating System Compatibility 1-2 Storage Requirements 1-2 Features 1-2 Storage Management Software Overview 1-3 2 Installing the Driver Installing the Driver in a New Windows System 2-2 Installing the Driver in an Existing Windows System 2-3 Installing Red Hat or SuSE Linux 2-3 Installing the Red Hat Driver in a New Linux System 2-3 Installing the SuSE Driver in a New Linux System 2-4 Installing or Updating the Driver in an Existing Red Hat or SuSE Linux System 2-5 Installing the Netware Driver in a New NetWare System 2-6 Installing or updating device drivers after installing NetWare 2-7 Updating the Device Drivers 2-7 Installing the Device Drivers 2-7 3 Installing and Starting Adaptec Storage Manager Installing Storage Manager on Windows 3-2 Installing Storage Manager on Linux 3-3 Installing Storage Manager on NetWare 3-4 Starting Storage Manager 3-5 Logging into Remote Systems 3-5
  • 4. iv Contents 4 Understanding Adaptec Storage Manager Introduction 4-1 Features 4-1 Overview 4-2 Physical Devices View 4-3 Logical Devices View 4-3 Changing How Drives are Displayed 4-4 Collapsed and Expanded Views 4-4 Component Views 4-5 5 Adaptec RAID Configuration Utility Using the Array Configuration Utility 5-2 Managing Arrays 5-2 Creating Arrays 5-3 Add/Delete Hotspares 5-6 Initializing Disk Drives 5-6 Rebuilding Arrays 5-7 Verifying Drives 5-8 Using the Disk Utilities 5-8 Glossary Index
  • 5. 1-1 1 Introduction In this Chapter... Overview Adaptec Embedded Serial ATA RAID with HostRAID® adds RAID functionality to the Serial ATA I/O controller by supporting RAID levels 0, 1, and 10. What is HostRAID? HostRAID adds entry level RAID support to the Serial ATA I/O controller. With HostRAID, you can add reliable performance and full data protection. Overview 1-1 Operating System Compatibility 1-2 Storage Requirements 1-2 Features 1-2 Storage Management Software Overview 1-3
  • 6. 1-2 Introduction Operating System Compatibility Note: The HostRAID embedded software product supports the following operating systems. However, depending on the vendor and specific configuration of your system, it is possible that only some of these operating systems are supported. Consult your hardware vendor to clarify operating system support. s Microsoft® Windows® 2000, Windows Server® 2003, Windows XP, and IA-32 s Linux s Red Hat Advanced Server 2.1 and 3.0 s SuSE SLES 8.0 and 8.2 s SuSE 9.0 s United Linux 1.0 s Miracle Linux 2.1 s Novell NetWare 6.5 Storage Requirements Device drivers and storage management software require approximately 20 MB of disk space. Features Adaptec Embedded Serial ATA RAID supports: s RAID levels 0, 1, and 10 using Adaptec’s HostRAID technology. s Operating system independent configuration and RAID creation using Adaptec RAID Configuration (ARC). s Easy array configuration and status using Adaptec Storage Manager. Install Adaptec Storage Manager as described in Chapter 3, Installing and Starting Adaptec Storage Manager.
  • 7. 1-3 Introduction s Hot swap rebuild of fault tolerant arrays through the operating system. s Event logging and broadcasting, including messaging for alphanumeric pagers. Storage Management Software Overview Adaptec Embedded Serial ATA RAID includes the following software tools to manage your storage subsystem: s Adaptec Storage Manager—A storage management application that provides you with an easy-to-use graphical interface to manage your storage subsystem. For details, see Chapters 3 and 4. s Adaptec RAID Configuration (ARC) Utility—Part of the controller’s built-in BIOS code. You start ARC by pressing Ctrl+A during BIOS startup. For details, see Chapter 5, Adaptec RAID Configuration Utility. s Array Configuration Utility (ACU)—A DOS/BIOS application used to create, configure, and manage arrays. For details, see Chapter 5, Adaptec RAID Configuration Utility. Note: You must have the most recent versions of Adaptec Storage Manager and ARC utility installed to run the Adaptec Embedded SATA RAID drivers.
  • 8. 2-1 2 Installing the Driver In this Chapter... This chapter describes installing the driver and setting up the new array for the drives attached to your controller. Before you get started, you need to select from the following scenarios for installing the controller driver on Windows, Linux, or NetWare systems: s Installing the Driver in a New Windows System on page 2-2 s Installing the Driver in an Existing Windows System on page 2-3 s Installing Red Hat or SuSE Linux on page 2-3 s Installing the Netware Driver in a New NetWare System on page 2-6 s Installing or updating device drivers after installing NetWare on page 2-7 Note: You must have the most recent versions of Adaptec Storage Manager and ARC utility installed to run the Adaptec Embedded SATA RAID drivers. Installing the Driver in a New Windows System 2-2 Installing the Driver in an Existing Windows System 2-3 Installing Red Hat or SuSE Linux 2-3 Installing the Netware Driver in a New NetWare System 2-6 Installing or updating device drivers after installing NetWare 2-7
  • 9. 2-2 Installing the Driver Installing the Driver in a New Windows System In this scenario, you are installing the driver in a new system that has no operating system. To install the driver: 1 Create a driver disk by following the instructions from the Web site or the product CD. 2 Restart the computer. 3 If creating an array, press Ctrl+A when prompted to enter the ARC utility. For instructions on creating an array from the BIOS, see Chapter 5, Adaptec RAID Configuration Utility. 4 When the array is finished building, insert the Windows setup CD and restart the system. 5 Press F6 when prompted to install a third-party driver. Note: When F6 is active, a prompt appears at the bottom of the screen. Press F6 immediately—you only have 5 seconds. If you miss your chance, restart this Windows installation to complete it correctly. Otherwise, Windows will not recognize your controller. 6 Insert the driver disk you created in Step 1 and wait until prompted to install a driver. 7 Press S to specify that the driver is on the floppy disk, then press Enter. Windows searches the disk for a suitable driver. 8 When the Adaptec Embedded Serial ATA HostRAID driver is found, press Enter. Follow the remaining on-screen instructions to complete your installation.
  • 10. 2-3 Installing the Driver Installing the Driver in an Existing Windows System In this scenario, you are installing a driver in a system that already has a Windows operating system. To install the driver: 1 Create a driver disk by following the instructions from the Web site or the product CD. 2 Start Windows. Windows launches the Found New Hardware Wizard, which searches for the controller driver. 3 Insert the driver disk you created in Step 1, select the floppy disk drive as the source then click Next. 4 If necessary, select the appropriate driver for your operating system. 5 Click Next as needed to complete the controller installation. 6 Remove the driver disk. 7 If prompted, restart the computer. 8 Your installation is complete. If you want to create an array from the BIOS, see Chapter 5, Adaptec RAID Configuration Utility. If you want to create an array from the operating system, see Chapter 4, Understanding Adaptec Storage Manager. Installing Red Hat or SuSE Linux Installing the Red Hat Driver in a New Linux System In this scenario, you are installing the driver in a new Red Hat Linux system. To install the driver: 1 Create a driver disk by following the instructions from the Web site or the product CD. 2 Restart the computer. 3 If creating an array, press Ctrl+A when prompted to enter the ARC utility. For instructions on creating an array from the BIOS, see Chapter 5, Adaptec RAID Configuration Utility. 4 When the array is finished building, insert the Red Hat CD Disk 1 in the CD-ROM drive then restart the system.
  • 11. 2-4 Installing the Driver 5 When the Red Hat Welcome screen appears, type expert or linux dd at the boot prompt. 6 When prompted, insert the driver disk (see Step 1) then select OK. 7 Follow the prompts to set up your preferred environment. 8 If you intend to install other third-party devices, proceed with the installation of those devices. Otherwise, select Done. 9 Continue with the Linux installation according to the Red Hat documentation. Installing the SuSE Driver in a New Linux System In this scenario, you are installing the driver in a new SuSE Linux system. To install the driver: 1 Create a driver disk by following the instructions from the Web site or the product CD. 2 Restart the computer. 3 If creating an array, press Ctrl+A when prompted to enter the ARC utility. For instructions on creating an array from the BIOS, see Chapter 5, Adaptec RAID Configuration Utility. 4 When the array is finished building, insert the SuSE CD Disk 1 in the CD-ROM drive then restart the system. 5 When the SuSE Installation menu appears, press the F3 key, then select installation option from the Menu then press Enter. 6 When prompted, insert the driver disk you created (see Step 1) then press any key to continue. 7 Follow the prompts to set up your preferred environment. 8 Continue with the Linux installation according to the SuSE documentation.
  • 12. 2-5 Installing the Driver Installing or Updating the Driver in an Existing Red Hat or SuSE Linux System To install the driver in an existing Red Hat or SuSE Linux system: If Driver Files Are On A Web Site 1 Create an rpm diskette for your Linux distribution and version. 2 Insert the rpm diskette into the floppy diskette drive then open up a command shell. From the shell type: mount /dev/fd0 /mnt/floppy cd /mnt/floppy rpm -ivh <rpmfile> (for a new install, or) rpm -Uvh --force <rpmfile> (for an updated install) 3 Reboot the system to enable the new/updated driver. If Driver Files Are On The Product CD 1 Insert the driver CD into the CD device and wait for the system to automount the cd, or manually mount it from a shell by typing: mount /dev/cdrom /mnt/cdrom 2 Then type: cd /<directory of rpm files> 3 Type: rpm -ivh <rpmfile> (for a new install, or) rpm -Uvh --force <rpmfile> (for an updated install) cd umount /mnt/cdrom or eject (to eject disc) 4 Reboot the system to enable the new/updated driver.
  • 13. 2-6 Installing the Driver Installing the Netware Driver in a New NetWare System Note: For information about installing drivers if you use the NetWare CD to install your operating system, see your Novell documentation. Use these steps to install the driver in a new Novell NetWare 6.5 system. To install the driver: 1 Use the instructions provided in the NetWare manual to begin the installation. 2 When the Choose the Server Drivers - Disk Driver prompt appears during the installation process, select Storage adapters; then, press Enter. 3 If the list contains the HostRAID SATA driver (AARICH.HAM) or (AAR81XX.HAM), select the driver then press the Delete key to delete it. 4 Press the Insert key twice to Add an unlisted driver. 5 Insert the support diskette for Novell NetWare. 6 Press F3 to specify a path then type a: (where a is the diskette drive letter) then press Enter. Note: The driver and support files will be copied to the system volume: either AARICH.HAM or AAR81XX.HAM. 7 Verify that the driver name displays in the list of device drivers that appears in the window (for example, AARICH.HAM) then select Return to Driver Summary then press Enter. 8 Select Continue then press Enter. 9 Follow the instructions in the NetWare manual to complete the installation.
  • 14. 2-7 Installing the Driver Installing or updating device drivers after installing NetWare To update the driver in an existing NetWare 6.5 system see Updating the Device Drivers. To install the driver in an existing NetWare system, see Installing the Device Drivers. Updating the Device Drivers 1 From the system console, type the following and press Enter then: Unload driver_name where driver_name is AARICH or AAR81XX For example: Unload AARICH 2 Do not restart the system; continue with the instructions for Installing the Device Drivers. Installing the Device Drivers 1 Start the NetWare hdetect utility program. From the system console, type the following then press Enter: load hdetect 2 Insert the HostRAID support diskette for Novell NetWare into the floppy diskette drive. 3 When you see the prompt Sys volume not mounted. Load driver anyway?, select Yes then press Enter to continue. 4 The device driver window opens, showing a list of storage adapters. Select Modify. 5 Press Enter to continue then select Modify. 6 Select the driver then press the Delete key to delete it. 7 When the next window opens, press the Insert key twice to add a driver.
  • 15. 2-8 Installing the Driver 8 When the next window opens, press F3 to specify a different path. 9 In the Specify a directory path field, type a: (where a is the diskette drive letter) then press Enter. 10 After the installation program copies all the files, press Esc to exit the hdetect utility. Note: If you want NetWare to load the HostRAID device driver automatically during startup, you must add the appropriate LOAD command to the NetWare startup command file (usually C:NWSERVERSTARTUP.NCF). The command has the form: load [pathname]driverslot=number [options] For example: load c:nwservera320raid.ham slot=1
  • 16. 3-1 3 Installing and Starting Adaptec Storage Manager In this Chapter... After you have installed your Adaptec RAID controller and driver, you are ready to install and use Adaptec Storage Manager—a user-friendly graphical user interface (GUI) that makes it easy for you to create and manage arrays without having to restart the computer and use the BIOS utility. Note: You need administrator or root privileges to install Storage Manager. For details on verifying privileges, refer to your operating system documentation. Installing Storage Manager on Windows 3-2 Installing Storage Manager on Linux 3-3 Installing Storage Manager on NetWare 3-4 Starting Storage Manager 3-5 Logging into Remote Systems 3-5
  • 17. 3-2 Installing and Starting Adaptec Storage Manager Installing Storage Manager on Windows This section provides instructions for installing Storage Manager. Note: On Windows, Storage Manager supports up to 16 Adaptec RAID controllers. To install Storage Manager: 1 Insert the product installation CD and wait for the Autorun executable to start the installation. If this does not occur, browse the CD and click Autorun. 2 When the installation wizard starts, follow the instructions on the screen to complete the installation. Note: When prompted to install SNMP (Simple Network Management Protocol), accept the default (do not install) unless you have a specific requirement for Storage Manager to work with SNMP gets and traps.
  • 18. 3-3 Installing and Starting Adaptec Storage Manager Installing Storage Manager on Linux Notes: s With Linux, Storage Manager supports up to 12 Adaptec RAID controllers. s Storage Manager includes the Java Runtime Environment (JRE). s If a previous version of Storage Manager is already installed and you are upgrading, you must first remove that version. Any customization files you may have created when you used the previous version are saved and used in the upgrade. To remove Storage Manager, type the rpm --erase StorMan command. s For the latest on Adaptec’s support of Linux, visit www.adaptec.com. To install Storage Manager: 1 Insert the product installation CD. 2 Mount the product installation CD: 3 Change to the cdrom directory: 4 Extract the RPM package and install it: rpm --install ./StorMan*.rpm 5 Unmount the product installation CD: for Red Hat mount /dev/cdrom /mnt/cdrom for SuSE mount /dev/cdrom /media/cdrom for Red Hat cd /mnt/cdrom/linux/manager for SuSE cd /media/cdrom/linux/manager for Red Hat umount /mnt/cdrom for SuSE umount /media/cdrom
  • 19. 3-4 Installing and Starting Adaptec Storage Manager Installing Storage Manager on NetWare Notes: s With NetWare, Storage Manager supports up to 16 Adaptec RAID controllers. s You need the latest Support Pack for your operating system so you can run the supported Java Virtual Machine (JVM). s You need JVM version 1.3 or later. To check your JVM version, load JVM, type JAVA -VERSION. s For the latest updates from Novell, visit www.novell.com. To install Storage Manager: 1 Insert the product installation CD. 2 From the command prompt, type load cdrom then press Enter. 3 From the command prompt, type: RaidMan:netwaremanagerinstall The installation program starts. 4 Follow the instructions on the screen to complete the installation.
  • 20. 3-5 Installing and Starting Adaptec Storage Manager Starting Storage Manager Note: You need root privileges to run Storage Manager. To start Storage Manager, use the procedure outlined in the table below for your operating system. Logging into Remote Systems To log into a remote system: 1 Click Remote > Add Remote System. Storage Manager displays the login screen, as shown below. Ifyouroperating system is... Start Storage Manager as follows... Windows To run Storage Manager as a standalone application, click Start > Programs > Adaptec Storage Manager, then select the appropriate icon. Linux Change to the directory where you installed Storage Manager by typing cd /usr/RaidMan then use the sh RaidMan.sh shell command. NetWare Type the LOAD RAIDMAN command.
  • 21. 3-6 Installing and Starting Adaptec Storage Manager 2 Type the IP address. The default System startup port number, 34571, is supplied for you. 3 For Username, type admin 4 For Password, type adaptec Note: The username and password are case sensitive. Once you are logged in for the first time, you can add new accounts and change account passwords. For details, refer to the online Help.
  • 22. 4-1 4 Understanding Adaptec Storage Manager In this Chapter... Introduction This chapter provides an overview of Adaptec Storage Manager, the user-friendly GUI that you use to easily create and manage arrays. For more details on using Adaptec Storage Manager to set up and manage arrays, refer to the online Help. Features You can use Adaptec Storage Manager to: s Create and delete arrays s Verify arrays s Migrate arrays s Add and remove hotspares s Change RAID level Introduction 4-1 Overview 4-2 Changing How Drives are Displayed 4-4 Collapsed and Expanded Views 4-4 Component Views 4-5
  • 23. 4-2 Understanding Adaptec Storage Manager s View the RAID configuration s View information about managed systems and subsystems such as arrays, logical drives, hot-spare drives, physical drives s Notify systems of all events occurring on the local system s Increase logical device size s Manage scheduled tasks such as Verify or Migrate s Add or remove a remote system s Configure, administer, and monitor controllers that are installed locally or remotely in your servers or external storage s Fine tune controller settings for optimal performance Note: Some of these features may not be available on your system. Check with your vendor, product documentation, or online Help for supported features. Overview Adaptec Storage Manager provides an expandable tree view of the systems and controllers you are managing. You can perform most configuration and management tasks by selecting a controller from the tree and working with related objects. The figure below shows how Adaptec Storage Manager displays information about Physical and Logical devices.
  • 24. 4-3 Understanding Adaptec Storage Manager Using the buttons in the Physical devices and Logical devices views, you can: s Change how drives are displayed. s Collapse and expand a view. s Identify components of a logical device. s Create and delete hotspares. Physical Devices View This view displays information about the drives, enclosures, and other physical devices attached to the controller. The devices are organized numerically. The display for each channel or port includes information on maximum speed, the number of the channels on the controller, and the number of devices attached to the controller. Indicators, next to the controller name, report status of the fan and temperature modules on SAF-TE (enclosure management) devices and other devices that monitor these conditions. The indicator colors are: s Blue—Normal s Yellow—Warning s Red—Error s Gray—Not applicable to the devices. For example, the fan indicator changes to yellow when one fan fails; it changes to red when a second fan fails and cooling is no longer adequate. Logical Devices View This view displays information about the logical devices created using the physical devices, including the number of logical devices, the RAID level of each device, and whether a logical device is protected by a hotspare. You can create and delete logical devices in the Logical devices view by selecting the Create option and using the Create wizard.
  • 25. 4-4 Understanding Adaptec Storage Manager Changing How Drives are Displayed You can choose how information is displayed in the Physical devices view by clicking one of the following buttons in the Logical devices view. Collapsed and Expanded Views You can display a collapsed or expanded view of the system configuration. Initially, Storage Manager displays a collapsed textual view of the configuration information in both the Logical devices and Physical devices views. Displays physical device information in text format. This is the default view. Displays physical device information in full size capacity format. A full-length bar is displayed for each drive, regardless of capacity. A small segment on each drive is reserved for the RAID signature; this area is indicated by a gray cap at the end of each bar. Note: A drive shaded in light blue is not part of any disk group. Displays physical device information in relative size capacity format. A full-length bar is displayed for the largest drive; proportionally shorter bars are displayed for other drives. In the Logical devices view... Click to expand and collapse information about disk groups and logical devices. The expanded display shows the following information about each logical device: s Disk group name and capacity (if available) s Logical device size s Logical device state s Build progress In the Physical devices view... Click to expand and collapse information about physical drives. The expanded display shows the following information about each drive: s Capacity of the drive s Drive ID s Drive state
  • 26. 4-5 Understanding Adaptec Storage Manager Component Views When you click a physical or logical device in the device views, the related components are highlighted in the other view. s When you click a logical device in the Logical devices view, the physical drives that make up the logical device are highlighted in the Physical devices view, and vice-versa. s When you click a hotspare, the logical devices protected by that spare are highlighted. s In the graphical views, if the logical device uses only part of the available storage, only those segments are highlighted (in dark blue).
  • 27. 5-1 5 Adaptec RAID Configuration Utility In this Chapter... The Adaptec RAID Configuration (ARC) utility is an embedded BIOS utility that includes: s Array Configuration Utility (ACU)—Used to create, configure, and manage arrays. s Disk Utilities—Used to format or verify disks. To run ARC, press Ctrl+A when prompted by the following message during the system startup: Press <Ctrl><A> for Adaptec RAID Configuration Utility The ARC menu appears, presenting these options: s Array Configuration Utility (ACU) s Disk utilities To select an option from this menu, or from any of the menus within ARC, browse with the arrow keys, then press Enter. In some cases, selecting an options displays another menu. To return to the previous menu at any time, press Esc. Using the Array Configuration Utility 5-2 Using the Disk Utilities 5-8
  • 28. 5-2 Adaptec RAID Configuration Utility Using the Array Configuration Utility The Array Configuration Utility (ACU) enables you to create, manage, and delete arrays from the controller’s BIOS, add and delete spare drives, and initialize drives. Managing Arrays Select the Manage Arrays option to view array properties and members, and delete arrays. The following sections describe these operations in greater detail. Viewing Array Properties To view the properties of an existing array: 1 At the BIOS prompt, press Ctrl+A. 2 From the ARC menu, select Array Configuration Utility (ACU). 3 From the ACU menu, select Manage Arrays. 4 From the List of Arrays dialog box, select the array you want to view then press Enter. The Array Properties dialog box appears, showing detailed information on the array. The physical disks associated with the array are displayed here. 5 Press Esc to return to the previous menu. Deleting Arrays Caution: Back up the data on an array before you delete it. Otherwise, all data on the array is lost. Deleted arrays cannot be restored. To delete an existing array: 1 Turn on your computer and press Ctrl+A when prompted to access the ARC utility. 2 From the ARC menu, select Array Configuration Utility (ACU). 3 From the ACU menu, select Manage Arrays. !
  • 29. 5-3 Adaptec RAID Configuration Utility 4 Select the array you wish to delete then press Delete. 5 In the Array Properties dialog box, select Delete then press Enter. The following prompt is displayed: Warning!! Deleting the array will render array unusable. Do you want to delete the array?(Yes/No): 6 If you press Yes, select the member when the following prompt is displayed: To delete the partition table, choose which member: member #0, member #1, both, none 7 Press Esc to return to the previous menu. Creating Arrays Before creating arrays, make sure the disks for the array are connected and installed in your system. Note that disks with no usable space are shown in gray and cannot be used. See Initializing Disk Drives on page 5-6. To create an array: 1 Turn on your computer and press Ctrl+A when prompted to access the ARC utility. 2 From the ARC menu, select Array Configuration Utility (ACU). 3 From the ACU menu, select Create Array. 4 Select the disks for the new array then press Insert. To deselect any disk, highlight the disk then press Delete. 5 Press Enter when both disks for the new array are selected. The Array Properties menu displays. Assigning Array Properties Note: Once the array is created and its properties are assigned, you cannot change the array properties using the ACU. Instead, use Adaptec Storage Manager (See Chapter 4 for details.)
  • 30. 5-4 Adaptec RAID Configuration Utility To assign properties to the new array: 1 In the Array Properties menu, select an array type then press Enter. Note that only the available array types, RAID 0, RAID 1 and RAID 10 are displayed. RAID 0 and RAID 1 requires two drives. RAID 10 requires four drives. 2 Type in an optional label of no more than 15 characters for the array, then press Enter. 3 For RAID 0, select the desired stripe size. Available stripe sizes are 16, 32, and 64 KB (default). Note: Adaptec recommends that you do not change the default. 4 The options under Create Using allows you to select between the different creation methods for RAID 0, RAID 1, and RAID 10. The following table gives examples of when each is appropriate. RAID Level Create Using When Appropriate RAID 0 No Init Creating a RAID 0 on new drives. RAID 0 Migrate1 1 If you select Migrate for RAID 0 or Build for RAID 1 or RAID 10, you will be asked to select the source drive. The contents of the source drive will be preserved. However, the data on the new drive will be lost. Creating a RAID 0 from one new drive and one drive with data you wish to preserve. RAID 1 Build1 Any time you wish to create a RAID 1, but especially if you have data on one drive that you wish to preserve. RAID 1 RAID 10 Clear Creating a RAID 1 or RAID 10 on new drives, or when you want to ensure that the array contains no data after creation. RAID 1 RAID 10 Quick Init Fastest way to create a RAID 1or RAID 10. Appropriate when using new drives.
  • 31. 5-5 Adaptec RAID Configuration Utility Notes: s Before adding a new drive to an array, back up any data contained on the new drive. Otherwise, all data will be lost. s If you stop the Build or Clear process on a RAID 1 or RAID 10 from ACU, you can restart it by pressing Ctrl+R. s A RAID 1 created using the Quick Init option may return some data miscompares if you later run a consistency check. This is normal and is not a cause for concern. s The ACU allows you to use drives of different sizes in a RAID 1 or RAID 10. However, during a build operation , only the smaller drive can be selected as the source or first drive. s When migrating from single volume to RAID 0, migrating from a larger drive to a smaller drive is allowed. However, the destination drive must be at least half the capacity of the source drive. s Adaptec does not recommend that you migrate or build an array on Windows dynamic disks (volumes), as it will result in data loss. Caution: Do not interrupt the creation of a RAID 0 using the Migrate option. If you do, there is no way to restart, and no way to recover the data that was on the source drive. 5 When you are finished, press Done. Adding/Removing a Bootable Array To make an array bootable: 1 From the Main menu, select Manage Arrays. 2 From the List of Arrays, select the array you want to make bootable, then press Ctrl+B. An asterisk will appear next to the bootable array. 3 To make the array nonbootable, select it then press Ctrl+B. The asterisk will disappear next to the array indicating that it is nonbootable. !
  • 32. 5-6 Adaptec RAID Configuration Utility Add/Delete Hotspares Select the Add/Delete Hotspares option to add, delete, or view hot spares. 1 Turn on your computer and press Ctrl+A when prompted to access the ARC utility. 2 From the ARC menu, select Array Configuration Utility (ACU). 3 From the ACU menu, select Add/Delete Hotspares. 4 Use the up and down arrow keys to highlight the disk you want to designate as a Hotspare, then press Insert>Enter. 5 Press Yes when the following prompt is displayed: Do you want to create spare? (Yes/No) The Spare you have selected will appear in the Selected Drive menu. Initializing Disk Drives Caution: If the drive is used in an array, you may not be able to use the array again. Do not initialize a disk that is part of a boot array. To determine which disks are associated with a particular array, see Viewing Array Properties on page 5-2. To initialize drives: 1 Turn on your computer and press Ctrl+A when prompted to access the ARC utility. 2 From the ARC menu, select Array Configuration Utility (ACU). 3 Select Initialize Drives. 4 Use the up and down arrow keys to highlight the disk you wish to initialize then press Insert. 5 Repeat Step 4 if you want to add another drive to be initialized. 6 Press Enter. !
  • 33. 5-7 Adaptec RAID Configuration Utility 7 Read the warning message and ensure that you have selected the correct disk drives to initialize. Type Y to continue. Rebuilding Arrays Note: Rebuilding applies to Fault Tolerant arrays (RAID 1 and RAID 10) only. By replacing a failed disk of a RAID 1 or RAID 10 array with a new disk, you can Rebuild to get the array to Optimal status and assume fault tolerance. You can perform a Rebuild in the following ways: Note: If no spare exists and a hard disk drive fails, you need to create a spare before you can rebuild an array. See Add/Delete Hotspares on page 5-6 before continuing your Rebuild. System Shutdown Rebuild You can shutdown the system and replace the failed disk with a new one (of equal or greater capacity). Once the system is booted, a new drive can be assigned as the spare drive, and this will start the Rebuild task. All the data from the good disk is copied to the new one, and the original RAID 1 or RAID 10 array is recreated. Manual Rebuild 1 From the Main Menu, select Manage Arrays. From the List of Arrays, select the array you want to Rebuild. 2 Press Ctrl+R to Rebuild.
  • 34. 5-8 Adaptec RAID Configuration Utility Verifying Drives If you are notified of a mismatch of data during a build of RAID 1 or RAID 10, you have an option of verifying your drives. To Verify the drives: Note: You will only have the Verify option available if the array is Optimal. If the array has failed, you will need to rebuild the array. 1 Select the drives you need to verify. 2 Press Ctrl+S. 3 When the Verify is complete, you will be notified with any errors found during the Verify operation. Using the Disk Utilities The Disk Utilities enable you to format or verify the media of your Serial ATA hard disks. To access the disk utilities: 1 Turn on your computer and press Ctrl+A when prompted to access the ARC utility. 2 From the ARC menu, select Disk Utilities. 3 Select the desired disk then press Enter. You are offered the following options: s Format Disk—Simulates a low-level format of the hard drive by writing zeros to the entire disk. Serial ATA drives are low-level formatted at the factory and do not need to be low-level formatted again. Caution: Formatting destroys all data on the drive. Be sure to back up your data before performing this operation. s Verify Disk Media—Scans the media of a disk drive for defects. !
  • 35. Glossary-1 Glossary A activity See task. ACU Array Configuration Utility. An application used to create, configure, and manage arrays from the controller’s BIOS or MS-DOS. array A logical disk created from available space and made up of one or more segments on one or more physical disks. Arrays are typically used to provide data redundancy or enhanced I/O performance. See also volume, spanned volume, RAID 0, RAID 1. Also known as a container. array initialization See initialize. ATA AT Bus Attachment. Standard parallel interface to IDE hard disks typically used in desktop computers and some entry-level servers. Serial ATA (SATA), is a successor to parallel ATA, which is sometimes referred to as PATA. available space/segment Unused space on an initialized disk from which logical devices (arrays) are created. When an array is deleted, the space that it used is returned to the available space pool.
  • 36. Glossary-2 Glossary B background consistency check Option that forces the controller to constantly check all portions of disks used by all arrays to see if the disks can return data from the blocks. See also consistency check command. bad segment Segment that is in an unknown state. bootable array Array configured as the boot device. build Background initialization of a redundant array. The array is accessible throughout. RAID 1 copies the contents of the primary drive to a secondary drive. See also clear. bus See channel. C cache Fast-access memory on the controller that serves as intermediate storage for data that is read from, or written to, drives. capacity Total usable space available in megabytes or gigabytes. channel Any path, or bus, used for the transfer of data and the control of information between storage devices and a RAID controller. For SATA channels, each channel has a single drive capacity.
  • 37. Glossary-3 Glossary check point A feature that enables you to exit the ACU when an operation is in progress and be able to continue without interruption. The driver then resumes the operation from where the BIOS left off and the BIOS resumes the operation where the driver left off. chunk See stripe. clear Foreground initialization of a fault-tolerant array. A clear operation zeros all blocks of the array. The array is not accessible until the clear task is complete. concatenation Joining of physical or logical drives in sequential order. consistency check command Command that reads all the blocks of a RAID 1 to determine if the blocks are consistent. Any inconsistent blocks are fixed. D dead partition See failed. degraded A redundant (for example, a RAID 1) array in which one or more members have failed. The data is intact but redundancy has been compromised. Any further failure would cause the array to fail and result in data loss. disk Physical disk drive. Randomly accessible, rewritable data storage device. Also called hard disk. disk ID Unique disk identifier that consists of the channel number, SATA ID. For example, (channel:ID:LUN) 1:04:0. See also channel.
  • 38. Glossary-4 Glossary drive LED Disk indicator LED that illuminates during read or write operations. E event Notification or alert from the system, indicating that a change has occurred. event log File used to maintain information about prior controller activities or errors. event notification Process for transmitting events. F failed State of a nonredundant array that has suffered a single drive failure, or a redundant array that has suffered multiple drive failures. A failed array is inaccessible and data is lost. fault-tolerant array Refers to an array that can continue to function after a disk drive failure without loss of data. Fault tolerant, or redundant arrays, include RAID 1 arrays. See also Redundant. foreign disk Disk that has previously been initialized on another Adaptec RAID controller. The RAID signature on the disk allows the RAID controller to identify whether or not the disk was initialized on the controller it is currently connected to.
  • 39. Glossary-5 Glossary H hard disk drive Basic unit of nonvolatile, nonremovable, magnetic storage media. See also disk. hot swap To remove a component from a system, and install a new component while the power is on and the system is running. hotspare A spare hard disk that automatically replaces a failed hard disk on any array associated with any HBA. I impacted An impacted array is one which has been created but for some reason the initial build operation did not complete. All member drives are present and operational, and all data written to the array is protected. To optimize the array, run a Verify with Fix Task. initialize Process of preparing a disk for use by the controller. When a disk is initialized, the controller records the RAID signature on the disk. initialized array An array that is ready for data reads and writes. Arrays can be initialized by build or clear. L legacy disk Disk that contained a valid partition table when connected to the controller. The controller manages the disk as a legacy disk array where there is a one-to-one logical-to-physical mapping of array to disk.
  • 40. Glossary-6 Glossary logical device Volume comprised of space from one or more physical drives and presented to the operating system as if it were a single storage unit. low-level format Process performed by the drive firmware that completely cleans any data off the hard disk. M mirrored array/mirroring See RAID 1. monitoring Process of receiving, displaying, and logging system events. O offline array Array that can no longer be accessed. optimal The state of an array when it is fully operational. For redundant arrays, the entire array is protected. P partition A section of a disk storage device created by the operating system disk management program, in which data and/or software programs are stored. Computers have a primary operating system partition that contains the special files needed to boot the computer. Each operating system partition is assigned a unique drive letter, such as C or D. A single disk device can have multiple partitions. phantom object Object that represents a component that cannot be configured by the controller management software; for example, a missing drive.
  • 41. Glossary-7 Glossary Q quick init An array initialized using the Quick Init option is available immediately, with no on-going background controller activity. All data written to an array that has been quick initialized is protected. R RAID Redundant Array of Independent Disks (alternative definition Redundant Array of Inexpensive Disks). RAID 0 A single-level array consisting of two or more equal-sized segments residing on different disks. RAID 0 distributes data evenly across its respective drives in equal-sized sections called stripes. RAID 0 arrays are not redundant. RAID 1 Single-level array consisting of two equal segments residing on two different drives. Provides redundancy by storing identical copies on two drives. See also mirrored array/mirroring. RAID signature The area on each disk reserved for use by the RAID controller. RAID volume Concatenates two or more arrays of the same type. rebuild Background regeneration of redundant data on a RAID 1. redundant The ability of an array to maintain operability when one or more hardware failures occur. RAID 1 is redundant. In the event of a drive failure, redundant arrays can be restored to normal operation by replacing the failed drive and rebuilding the array.
  • 42. Glossary-8 Glossary rescan Process of updating the current screen to show all currently available resources. S Serial ATA (SATA) A successor to ATA that uses a serial, instead of parallel, interface. simple volume A volume made up of disk space from a single disk. It can consist of a single region on a disk, or concatenated multiple regions of the same disk. single-level array Array created from one or more segments. See also volume, spanned volume, RAID 0, RAID 1. snapshot Instantaneous read-only copy of an array at a precise point in time. spanned volume A simple volume that spans two or more drives. stripe Contiguous set of data distributed across all the disks in an array. A striped array distributes data evenly across all members in equal- sized sections called stripes. stripe size The amount of data in each section of a striped array. striped array See RAID 0.
  • 43. Glossary-9 Glossary T task An operation that occurs only on the RAID controller, asynchronous to all other operations; for example, initializing a disk or verifying an array. Some tasks can take an extended period of time, particularly if the RAID controller is also performing intensive data I/O while the task is running. V verify Low-level check that a drive, logical device, or hot spare is good. In a RAID 1, verify is a low-level check that contents of both members’ segments are consistent and, optionally, corrects errors while assuming that the master drive is correct. In a simple volume, verify performs a low-level check that the whole drive can be read. volume See simple volume, spanned volume.
  • 44. Index-1 Index A ACU overview 1-3 using to manage arrays 5-2 Adaptec RAID Configuration utility overview 1-3 Adaptec Storage componet views 4-5 Adaptec Storage Manager features 4-1 logical devices view 4-3 overview 1-3, 4-2 physical devices view 4-3 Array Configuration Utility. See ACU Array Properties dialog box deleting arrays 5-3 Arrays creating bootable arrays 5-2 arrays stripe size 5-4 B Bootable arrays creating 5-2 C Caching read 5-4 Containers creating with CCU 5-3 deleting 5-2 managing with CCU 5-2 D device drivers installing NetWare 2-7 updating NetWare 2-7 Disk Size Advisory 5-2 Disks initializing 5-6 size advisory 5-2 driver installation installing in existing Linux system 2-5 installing in existing NetWare system 2-7 installing in existing Windows system 2-3 installing in new Linux system 2-3 installing in new NetWare system 2-6 installing in new Windows system 2-2 F features 1-2 Format disk 5-8 H HostRAID overview 1-1 I Initializing Disks 5-6 initializing drives 5-6 installing NetWare driver 2-6
  • 45. Index-2 Index L Linux driver installation in existing system 2-5 in new system 2-3 M Manage Arrays option 5-2 N NetWare device drivers 2-7 NetWare driver installation 2-6 O operating system compatibility 1-2 R Read caching 5-4 Rebuilding arrays 5-7 S SCSI Disk Utilities 5-8 storage management software overview 1-3 storage requirements 1-2 stripe size 5-4 V Verify disk media 5-8 verifying drives 5-8 W Windows driver installation in existing system 2-3 in new system 2-2
  • 46. R Adaptec, Inc. 691 South Milpitas Boulevard Milpitas, CA 95035 USA ©2004 Adaptec, Inc. All rights reserved. Adaptec and the Adaptec logo are trademarks of Adaptec, Inc. which may be registered in some jurisdictions. Part Number: 513944-06, Ver. AA JG 07/04