SlideShare una empresa de Scribd logo
1 de 129
Descargar para leer sin conexión
Academy
καλωσόρισμα!
Training February 2020
Experience and innovation
We have been working since more than 40 years
in the HVAC and renewable energies field.
We produce integrated and efficient systems
for heating, cooling, domestic hot water, air treatment with
heat recovery
suitable for residential and commercial buildings
(hotels, sport centers, wellness centers, etc)
Integrated systems for energy savings
Heating
Cooling
Dehumidification
Solar
Hot
Water
Ventilation
Swimming
pools
Our watchwords
Comfort according to the needs and expectations of the
end customer, with the best ratio result/investment
Simplicity and speed concerning installation, use and
maintenance; easy and direct is also the relationship we build
with our partners
Energy savings exploiting renewable energies, reducing
wastes, and using smart managing systems
Integrated systems
The advantages of an integrated system
Unique supplier for the complete system
Supply of all needed components
Reduced installation costs
No redundancy of components
The same regulation logic in the whole system
Tested and approved solutions
Customized solutions
Heat pumps
● Heating
● Cooling
● Domestic hot water
● Pools
● Air-water
● DHW
Pompe di calore
aria-acqua
● Riscaldamento
● Raffrescamento
● Acqua sanitaria
● Piscine
Pellet and wood
stoves and boilers
● Heating
● Domestic hot water
● Easy management
● TÜV certified
Pompe di calore
aria-acqua
● Riscaldamento
● Raffrescamento
● Acqua sanitaria
● Piscine
Air treatment
● Air renewal
● Dehumidification
● Heat recovery
● Energy savings
Fan coil units
● Heating
● Cooling
● Low thickness
● Wall / Ceiling
● False ceiling
Radiant systems
● Heating
● Cooling
● Underfloor
● Wall / ceiling
Solar systems
● Domestic hot water
● Heating
● Pools
● Drainback systems
Thermoregulation
● Climatic
● Solar
● Smart control
● Remote control
● Energy savings
Central heating
● Components
● Accessorie
● Smart management
● No wastes
● Better result
IMPIANTI RADIANTI
ROSSATO GROUP
IMPIANTI RADIANTI
ROSSATO GROUP
Sustainability and Comfort
● Growing recognition across domestic consumer
● Growing demand for premium heating
● Stringent energy efficiency standards
● Development of digital home heating technologies
● Introduction of energy efficiency standards
● Increasing standard of living
● Strict government regulations
Global Market Insights, 2019-2025
IMPIANTI RADIANTI
ROSSATO GROUP
IMPIANTI RADIANTI
ROSSATO GROUP
Hotels & Offices
Energy efficiency in hospitality & commercial buildings
Hydronic underfloor heating Market:
+7,5% in 2025
Global Market Insights, 2019-2025
IMPIANTI RADIANTI
ROSSATO GROUP
IMPIANTI RADIANTI
ROSSATO GROUP
Radiant systems: why?
● Very high comfort
● Silent operation
● Design & décor freedom → More space for furniture
● Low power consumption
● Energy efficient operations → heat pumps
IMPIANTI RADIANTI
ROSSATO GROUP
IMPIANTI RADIANTI
ROSSATO GROUP
Limits of radiant systems
Available thickness of the floor: renovations
● Humidity control
● Performance with high outdoor temperature
● Economic investment
● Time to cool the room
● Hotel: sudden load variation (people coming in and out)
Special applications only 3cm
Ecofloor Tech
Cooling
Hotels / summer houses
IMPIANTI RADIANTI
ROSSATO GROUP
IMPIANTI RADIANTI
ROSSATO GROUP
Program
● Special application with underfloor heating: Ecofloor Tech
● Air handling with radiant systems: Dehumidifiers
● Air renewal and heat recovery: Mechanical Ventilation
● Dehumidifier + heat recovery all-in-one: Ecodry CN REC
● Heating/cooling with fan coil units: Iris Pack
● Mechanical ventilation with heating/cooling: VMC Clima
● Smart Control: Caleon / Caleonbox
● Practical demonstration
Low thickness radiant system
ECOFLOOR TECH
Low thickness
ECOFLOOR TECH panels have been designed
to get radiant floors with very low thickness:
● 30 mm with ECOFLOOR TECH 5
● 35 mm with ECOFLOOR TECH 10
● 45 mm with ECOFLOOR TECH 20
* with 10 mm of self-levelling screed on the knob
Applications
Applications:
● New houses
● Renovations
● Existing floors
● Premises with low available thickness
Field of use:
Heating
Cooling
ECOFLOOR TECH
● High density and low conductivity EPS insulation panel
● Footfall resistant HIPS 0,8 mm shell
● Knobs with pipe-holder profile
● Multiple 50 mm pipe spacing
● Male/Female perimeter interlocking system
INSULATION PANEL
Technical features Norm
U.M. ECOFLOOR TECH
5 10 20
Insulation thickness - mm 5 10 20
Knob height - mm 15
Total height - mm 20 25 35
Declared thermal conductivity λD UNI EN 13163:13 W/mK 0,032
Actual thermal resistance Rλ,ins
UNI EN 1264-3 m2
K/W 0,28 0,44 0,75
Compression strength at 10% with
deformation σ10
UNI EN 826:13 Kpa 400 500 500
INSULATION PANEL
Features U.M. Value
Outer diameter mm 14
Thickness mm 2
Water content l/m 0,079
Weight kg/m 0,075
Rolls m 150-280-500
ECOFLOOR TECH panel is combined with a
PE-RT14x2 pipe. With it it it is possible to realize
longer circuits compared to low thickness radiant
systems using 10 mm tubes reducing the number
of connections to the collector and therefore the
costs of the system.
LONGER CIRCUITS WITH PE-RT PIPE 14x2 mm
Low thickness: Advantages
● Quick heating when starting
(only 1 hr compared to 5 hr in traditional systems)
● Better response to thermoregulation
● High performance due to high conductivity and low thickness
● -3°C supply temperature compared to traditional systems
● Better heat diffusion because the self-levelling screed adheres well
Faster construction sites
● Light and small panels
● Highly footfall resistant shell
● No need of anti-shrinkage nets
● Absence of joints and crack-resistant mesh
● Quick drying and start-up within a few days (4 days or as recommended)
● 40% Cost savings compared with a “dry” radiant system
THICKNESS
1 - Baseboard
2 - Elastic filling
3 - PE edge insulation strip
4 - ECOFLOOR TECH
5 - Self-levelling screed
6 - PE-RT pipe 14x2 mm
ECOFLOOR TECH
Panel Hp (mm) Hm (mm) Ht (mm)
ECOFLOOR TECH 5 20 10 30
ECOFLOOR TECH 10 25 10 35
ECOFLOOR TECH 20 35 10 45
PRE-CONDITIONS
Make sure that the following conditions are met before proceeding:
● Internal plaster is finished
● Structural height has been verified
● Electric and hydraulic sistema are finished
● Niches to place the manifolds have been made
PRE-CONDITIONS
The support surface must be:
● Flat
● Load-bearing
● Stable and compact
● Clean
Measuring distance L (m) Allowed height difference d (mm)
1 3
4 9
10 12
15 15
Possible support / subgrade
● Cement-based screed
The substrate must be dimensionally stable and mechanically resistant according to the
intended use of the floor. The surface must be cleaned of dust, dirt and grease and any
cracks must be compensated to restore integrity and flatness.
● Lightened pre-screed
It must be stable, compact and with good compressive strength.
● Existing ceramic or stone cladding
Check, by tapping, that the covering is well fixed: any detached tiles must be removed
and the flatness of the support must be restored.
● Wooden, PVC, linoleum, rubber or other cladding
These coatings are not suitable to receive the ECOFLOOR TECH radiant system so they
should be removed together with the adhesive residues up to the support layer.
● Acoustic insulation
In this case, contact the technical office of the acoustic insulation manufacturer to know
the characteristics of the insulation or the minimum thickness required for the
self-levelling screed
Insulation panels laying
● Observe all safety instructions
● Make sure that air temperature is between +5 and +30°C
● Shake the canister vigorously in order to completely mix the content
● Use a dispensing gun and screw the adhesive canister onto it
● To optimize the foam, moisten the substrate with water mist.
● Proceed with the application of the adhesive using the dispensing gun
Insulation panels laying
● Apply the adhesive on panel lower surface taking care to make curbs
● Immediately press the panels down firmly
● After hardening, remove any excess foam
Distribution manifold
● Manifold 1” e 1”1/4 for radiant systems (as per UNI EN 1264)
● Optimized module geometry to reduce pressure drops
● Structure in fibreglass-reinforced polyamide anti-condensation
● Modular manifold 2-18 outputs
● Horizontal and vertical installation
Distribution manifold
MATERIALS
Nylon 6,6 glass-fibre reinforced at 30%, hydrolysis resistant
Stainless steel
Peroxide EPDM
TECHNICAL FEATURES
Shipping/storage temperature -10 ÷ 80 °C
Continuous operation temperature at 2 bar 2°C ÷ 100°C
Maximum operation temperature 120°C
Operation pressure at ambient temperature 0 bar ÷ 8 bar
Bursting pressure > 40 bar
Distribution manifold
● Flow meter valve for regulation 0-5 l/min
● Air vent
● Thermometer
● Connection for system load/ unload
Supply module
Distribution manifold
● Shut-off valve with manual knob ready for electro-thermic actuators
● Air vent
● Thermometer
● Connection for system load/ unload
Return module
Distribution manifold
● Remove the plugs from the manifold couplings
● Cut the pipes perpendicular to the axis at a distance of 30-39 mm cm from
the coupling (depending on the pipe)
● Prepare the end of the tube with countersink/calibrator
● Mark the bottom of the stroke (variable according to pipe diameter and type)
Required accessories are:
● cutter
● countersink/calibrator
Sliding quick push-in connectors
Manifold cabinet
DIMENSIONS OF CABINET (mm)
Length (A) 400 600 850 1000 1200
Height (B) 650
Depth (C) 110
DIMENSIONS OF DOOR (mm)
Width (I) 450 650 900 1050 1250
Height (H) 650
PLANNING
Planning: Heating load
Design and construction of a radiant system depends on following data:
● Available surface
● Customer needs
● Building and architectural requirements
● Building’s heating / cooling load
Without heating / cooling load information, the systems are sized with a
fixed heating load of 70 W/m2
.
Planning: Manifold position
● Manifold position
● Number of manifolds (also depending on
control system)
LR =AF/ T
AF =100 m2
T= 0,1 m
Lr=100/0,1=1000 m
Medium circuits length LC
=75 m
N° circuits 1000/75= 13
N° outlets = 13 + term. + dehum.
Prefer a barycentric position
Planning: Manifold position
The manifold position depends on the cabinet size, too
Air handling
Air handling
In accordance with EN 1264 the cooling flow temperature must not be more than 1 K
lower than the dew temperature calculated for the ambient conditions. (Example room
temperature of 26°C, relative humidity 50%: dew temperature is 14.8°C and flow
temperature cannot be lower than 13.8°C).
Supply temperature according to R.H.
Room temperature (°
C)
Relative humidity
%
Dew temperature Supply temperature
26 °C 55% 16,3 °C 15,3 °C
26 °C 60% 17,6 °C 16,6 °C
27 °C 55% 17,2 °C 16,2 °C
27 °C 60% 18,6 °C 17,6 °C
Low R.H. values allow to obtain higher performances from the radiant system
but require more energy
Air handling
The surface temperature must always be higher than the dew temperature.
medium air temperature
difference ∆ΘH
nominal temperature
difference
Air handling
● Set the flow temperature to have a surface temperature 2°C higher than
the corresponding dew temperature
● Size the dehumidifier for a dehumidification capacity equal to the latent
design load
● Use a control system that starts the dehumidifier when the design R.H.
threshold value is exceeded
● Use a control system that raises the supply temperature to the radiant
system when the design R.H. threshold value is exceeded.
Take these precautions to prevent surface condensation
Dehumidifiers
● Direct expansion systems with hydronic integration
● Air handling with sole circulation
● Neutral or cooled air supply
● Ductable or built-in version
● Management through system climate control
Dehumidifiers
Ecodry CN
Ecodry IN
Ducted system for several rooms Built-in unit for one single room
Model
Dehumidification l/g
T 26°C R.H. 65%
Water 15°C
Absorbed
power
W
Air flow
m3
/h
Operation
range
°C
Cooling power
W
CN+ 300 20,8 320 250 10÷30 -
CN+ 300 DC 20,8 320 250 10÷30 1.240
CN+ 600 48,2 750 600 10÷30 -
CN+ 600 DC 48,2 750 600 10÷30 3.230
Dehumidifiers
Ecodry CN Ecodry IN
Dehumidifiers
Model
Wall Wall Ceiling Ceiling Ceiling Ceiling
IN+300 IN+300 DC CN+300 CN+300 DC CN+600 CN+600 DC
Dehumidification capacity l/day 20,8 48
Cooling capacity W - 1240 - 1240 - 3230
Absorbed power W 320 700
Absorbed current A 2,15 5
Electrical supply V/ph/Hz 230/1+N/50
Tolerance of electrical supply % +/- 10
Air flow m3
/h 250 600
Useful static head Pa
Nominal water flow l/h 150 500
Water pressure drop kPa 15 30 29
Limit storage temperature °C -10/ +43
Limit storage humidity % 90
Sound pressure level db (A) 38 43
Weight kg 34 36 35 37 52 55
Dehumidifiers
HYDRAULIC AERAULIC
direct supply with dedicated pump
distribution with ventilation system
Mechanical ventilation
Training
Altair units: overview
Which unit?
Altair CP 100/200
Altair HR 301/501
Altair VR 301/601
Altair HRM
8-15-18-26-40
Main features
High energy class (A or B)
Low consumption fans (according to ErP 2015-2018)
High efficient heat recovery (up to 90%)
Filtering (class F7 filters for supply air and G4 for extraction air)
By pass (automatic bypass for free-cooling and free-heating)
Altair VR 401-601
UNIT CONTROL ENERGY CLASS
ALTAIR VR 401
CTR
B
ALTAIR VR 601 B
ALTAIR VRX 401
CTRX
B
ALTAIR VRX 601 A
● Vertical unit
● Size 400 - 600 m3
/h
● Static propylene heat exchanger in counterflow
● Total by-pass 100%
● Fans with electronic speed control
● Self-supporting structure in 25 mm thick sandwich panels
● Opening doors on the front for easy maintenance
A drain pipe with a syphon and a minimum slope of 3% must always be provided in order to prevent the condensation
water from becoming stationary.
Altair VR 401-601
Fresh air
Extraction
Inlet
Outlet Outlet
Outlet
Fresh air
Fresh air Outlet
Inlet Fresh air
Outlet
Inlet
Fresh air
Outlet
Fresh air
Fresh air
Outlet
Outlet
Inlet Inlet
Extraction
Extraction
Extraction
Outlet Fresh air
Altair HR 310-501
UNIT CONTROL ENERGY CLASS
ALTAIR HR 301
CTR
B
ALTAIR HR 501 B
ALTAIR HRX 301
CTRX
A
ALTAIR HRX 501 B
● Horizontal unit
● Size 330 - 460 m3
/h
● Static aluminium heat exchanger in counterflow
● Total by-pass 100%
● Fans with electronic speed control
● Double brushed sandwich aluzink structure with 25 mm insulation
● Opening doors on the side for easy maintenance
A drain pipe with a syphon and a minimum slope of 3% must always be provided in order to prevent the condensation
water from becoming stationary.
Altair CP 100 - 200
UNIT CONTROL ENERGY CLASS
ALTAIR CP 100
CTR
A
ALTAIR CP 200 A+
ALTAIR CPX 100
CTRX
A
ALTAIR CPX 200 A+
● Horizontal unit
● Size 120 - 460 m3
/h
● Static PP heat exchanger in counterflow
● Partial by-pass 80%
● Fans with electronic speed control
A drain pipe with a syphon and a minimum slope of 3% must always be provided in order to prevent the condensation
water from becoming stationary.
How to choose
0 m3
/h 90 m3
/h 200 m3
/h 300 m3
/h
70 m2
150 m2 220 m2
CP100/200 CP200/ HR301/ VR401 HR501/ VR601
DATA REFERRED TO MEDIUM SPEED OPERATION
Control
Training
Standard control CTR
ALARMS
SPEED
BY PASS STATUS
Frost protection
the heat exchanger is automatically protected from frost by temporary
unbalancing of the flow rates reducing/stopping the outdoor flow rate going
inside: with outlet air temperature below 3°C.
Standard control CTR
ALARMS Fans stop
Dirty filters
(signalled by
pressure switch or
hour counter)
ALARMS
Standard control CTR
SPEED
Speed control
LED ON: Speed 1-2-3
LED OFF: Unit off
Standard control CTR
BY PASS STATUS
● Fixed Led = Summer
→ by-pass off with outdoor T > inlet T + 2°C
● Led off = Winter
→ by-pass off with inlet T > outdoor T + 2°C
● Blinking Led
→ automatic (free-cooling/heating)
Tmin-Tmax 15°C - 22°C
Advanced control CTRX
ICON FOR
WINDOW CHANGE /
SCROLLING /
OK
After 1 minute of inactivity the screen switches to stand-by mode and flashes in
case of alarm!
Advanced control CTRX
Programming from 1 min to 4 h with Vmax and priority over the program.
● off: device shutdown
● xxx%: Continuously adjustable
speed between a minimum and a
maximum with 5% steps
● Auto: speed management based on
the control of a sensor (CO2
,
CO2
-VOC, relative humidity RH)
● Clock: speed management
according to the weekly
chronoprogram
Booster
Advanced control CTRX
● Daily setting (Mon-Fri Sat-Sun)
● Speed setting to 8 time slots with a
minimum resolution of 30 minutes
● Setting on three speed levels
● The Timetable offers an overview of
the week days over 24 hours
WEEK CHRONOPROGRAM
Advanced control CTRX
● Summer → by-pass off with outdoor T > inlet T + 2°C
● Winter → by-pass off with inlet T > outdoor T + 2°C
● Mid-seasons / automatic → automatic by-pass (free-cooling/heating)
BY-PASS
Advanced control CTRX
● CO2
sensor: auto min - auto max 0-1980 ppm
● VOC/CO2
sensor: auto min - auto max 20-2000 ppm
● Humidity sensor: auto min - auto max%
Room sensors
Advanced control CTRX
● with modulating PWM signal
● switching on with outlet air below 3°C
● 100% switching on with outlet air at 1°C (values can be changed on request)
Pre-heating on Pre-heating off
Air distribution
Training
Air distribution system
● Insulated distribution plenum for inlet/outlet
● Flow rates from 250 m3
/h to 480 m3
/h
● Pipe connection already installed in the plenum
Adjusting rings
Pre-cut calibration rings to remove by pressure
Air distribution system
● Double-walled food-grade polyethylene pipe, corrugated outside and
smooth inside
○ outer layer → resistant to chemical aggression of concrete and flame
resistant
○ inner layer → smooth antistatic and antibacterial HDPE film
● Diameter 75/63 mm max 35 m3
/h
● Diameter 90/76 mm max 60 m3
/h
● Radius of curvature 7 x DN
● Crushing resistance 450 N (with 5% outside diameter deformation)
● Pre-insulated version with 3 mm layer of grey colour for heating/cooling
Silent operation
The "single duct for single room" system
prevents the cross-talking effect and
guarantees silence and privacy.
Additional precautions
● Silencers in the duct
● Low air speed in the ducts (max 3,5 m/s)
● Vibration dampers
● Acoustic insulation of the technical room
Air diffusion indoor
PVC grids with slits or
swivelling flaps
Ventilation valves
Linear air vents
Galvanized sheet metal
adapters with 2/3
reversible connections
on rear side face
Adapter for DN125 valve
with 2 caps
Air diffusion indoor
Ventilation principle Temperature difference between inlet air and air
in the breathing zone ∆t=tA
-tim
(°C)
Ventilation efficiency
Mixing ventilation Heating
∆t < -5
-2 < ∆t < -5
-2 < ∆t < 0
Cooling
0.4÷0.7
0.8
0.9
Cooling
0.9÷1.0
Mixing ventilation Heating
∆t < 0
Cooling
0 < ∆t < 5
∆t > 5
1.0
Cooling
0.9÷1.0
0.9
Displacement ventilation Heating
∆t < -2
-2 < ∆t < 0
Cooling
0 < ∆t
0.2÷0.7
0.7÷0.9
Cooling
1.2÷1.4
Outdoor terminal units
Wall grid for air outlet/ inlet D125 - D160/180 - D200 complete
with internal insect screen
Flush wall terminal unit for air outlet/ inlet in white painted
galvanized steel D125 - D160/180 - D200
frame
coarse insect filter
customizable screen*
flat screen
*The screen can be customized with the same material of the wall finishing
Outdoor terminal units: where?
● Far from pollutant source
● Shielded from prevailing winds
● Minimum 3 m higher than the street level (UNI 10339)
● Not in basement hopper nor aerated wasps to avoid radon contaminations
● 2 m far from air expulsion to avoid a short circuit (UNI 10339)
● Not too close to other buildings to avoid noise
Ventilation system: Steps
The customer needs
What does the customer need?
● Only mechanical ventilation
● Mechanical ventilation and dehumidifying
● Post-heating / cooling
● Ventilation and heating/cooling
Choose the type of system
The building site needs
What, Where and How can be made?
● Horizontal or Vertical unit
● The technical room where the unit will be installed
● Space for ventilation ducts
● Position of the plenum
● Position and kind of ventilation terminal units
● Position of outdoor terminal units
Collect the info and send them to our technical dpt
Position of the ventilation unit
PAY ATTENTION TO THE RESPECT SPACES AND THE
POSITION OF THE INSPECTION PANEL!!!
ALTAIR VR:
FRONT
ALTAIR HR:
SIDE
ALTAIR CP:
BOTTOM
Space for ventilation ducts
Underfloor
False ceiling
Wall
Position of the plenum
Technical room Technical room
False ceiling
Position of grids and valves
Wall
Ceiling / false ceiling
Project
Rossato draws the system layout
● The air exchange flows are defined
● The ventilation unit is sized
● The air system is sized
● The system layout is drawn
● The material are listed
● The system calibration settings are defined
Project
Installation
● Check that the project corresponds to the building site
● Install all components following the project
● Calibrate air flow through regulation rings on the collector
● Check air flows with measurement tools
● Start the system up
Example
Energy upgrading of a residential dwelling
● Thermal insulation
● Solar thermal + condensing boiler
● Photovoltaic
● New windows
● Mechanical ventilation
Example
75 m2
- 200 m3
ca
minimum exchange rate 100 m3
/h
4 people
140 m3
/h → 35 m3
/h for each person
Example
Example
The unit is installed under the roof
If the unit is placed in a not-heated room, we recommend to insulate the
distribution ducts to prevent energy loss from and towards the exchanger
Maintenance
Yearly ordinary maintenance
● Clean the filter with running water (2000 h)
● Clean the condensate tray
● Clean the exchanger
Extra ordinary maintenance
● Clean the air ducts with brushes, air brushes or vacuum cleaners
● Use sanitizing products
Dehumidifier + air renewal
Ecodry CN REC
Ecodry CN REC
Isothermal and DC version: supply 15°C
Direct expansion circuit
Pre/ post-treatment batteries
Air or water condensation for DC
version
Ecodry CN REC
IDRO version: supply 10°C
ECODRY CNREC IDRO units have
no refrigeration circuit and must
be supplied with cooled or heated
water: battery + 3 ways valve.
Air renewal + circulation
Air renewal + dehumidifier / cooling / heating as set
exhaust air expulsion
outdoor
(max 130 m3
/h)
outdoor fresh air
inlet (max 130 m3
/h)
exhaust air extraction
(max 130 m3
/h)
air supply indoor
(260 m3
/h)
indoor air suction
(max 260 m3
/h)
Air circulation
indoor air suction
supply air indoor
Circulation + dehumidification / cooling / heating as set
260m3
/h
260m3
/h
Air renewal
0 - MIN - MED - MAX
Winter - mid seasons
0 - MIN - MED - MAX
0 - MIN - MED - MAX
0 - MIN - MED - MAX
Ecodry CN REC: functioning
1
2
3
4
5
Renewal
Outlet
Inlet
Circulation
Extraction
Ecodry CN REC: example
heating/ cooling with fan coil units
Training
Iris Pack
Iris Pack: components
Iris CN 600-800 Plenum + air ducts + valves
Ducted fan coil unit + air distribution system
→ ducts with the same diameter
Applications
Applications:
● Heating with boilers and heat pumps
● Cooling with heat pumps and chillers
● Residential and commercial dwellings
● Integration for heating/cooling systems in
existing systems
Field of use:
Heating
Cooling
Main features
● Easy integration in the architecture
● No visible components
● Low air speed
● Silent operation
● Complete system with all accessories
● Easy air flow balancing
● Easy and quick installation
● Uniform air diffusion
Comfort and aesthetic
Complete and ready system
IRIS CN 800
● Reduced energy consumption
● Brushless fans with variable speed control
● Silent operation
● Small dimensions (only 275 mm thickness)
● Invisible installation in false ceiling
Ducted fan coil unit
Components
● Inlet plenum designed to ensure balanced
air distribution at low speed.
● 9 pre-cut connections: 7 on front and 2 on
side
● All connections have the same diameter Ø
125 mm.
The number of ducts must vary according to the air flow rate in order
to maintain the speed below 4 m/s.
Inlet plenum
Components
● Designed to to adapt to different
architectural requirements
● pre-cut connections on the bottom and on
the side
● Telescopic extension to adapt the plenum
to different false ceiling heights
Outlet plenum
The grid can be placed:
● directly on the unit’s plenum
● on the unit’s plenum through the
telescopic extension
● on a second plenum a bit far
from the unit through flexible
ducts ø200mm
Components
● Half-hard duct in expanded cross-linked PE
● Antibacterial and anti-mould treatment
● Resistant and insulated
● Less pressure drops
Outlet air flow grid Inlet air flow grid Linear air vent Accessories
Components
Features Rotation speed M.U. IRIS CN 600 IRIS CN 800
Air flow (open-mouth unit)
H m3
/h 1.350 1.450
M m3
/h 1.080 1.175
L m3
/h 783 870
Total cooling power
(Inlet air 26°C d.b. R.H.55% - water 7-12°C)
H W 6.973 10.345
M W 6.251 9.332
L W 5.313 8.017
Sensible cooling power
(Inlet air 26°C d.b. R.H.55% - water 7-12°C)
H W 4.910 6.844
M W 4.259 5.986
L W 3.460 4.929
Water flow in cooling mode M l/h 1.075 1.605
Pressure drop in cooling M KPa 30,1 32,9
Heat output
H W 8.971 11.967
M W 7.867 10.558
L W 6.490 8.804
Water flow in heating mode
(Inlet air 20 °C d.b. - water 50-45°C)
M l/h 1.121 1.674
Pressure drop in heating
(Inlet air 20 °C d.b. - water 50-45°C)
M KPa 27,8 30,3
Components
Electrical data Rotation speed M.U. IRIS CN 600 IRIS CN 800
Power Supply V/PH/Hz 230/1/50
Current consumption W 290 290
Absorbed current A 1,3
Sound levels
H dB(A) 49 50
M dB(A) 43 44
L dB(A) 34 35
Example
● Apartment 75 m2
● Installation in false ceiling
● Outlet in the ceiling under the unit
● Heat demand: 5.900W (ca.80 W/m2
)
IRIS CN 600 at medium speed with
supply temperature 45°C
7 outlets from the front plenum
Room
Demand
W
Ducts
nr
Air flow
m3
/h
Grids
LR 2670 3 420 1 with 2 ducts + 1 with 1 duct
L 1780 2 280 1 with 2 ducts
K 890 1 140 1 with 1 duct
WC 890 1 140 1 with 1 duct
Example
LIST OF MATERIALS IRIS PACK WITH IRIS CN 600
Code Description M.U. Quantity
01VC02001 IRIS CN 600 pc 1
05DM91001 Inlet plenum pc 1
05DM60M12 Flanged sleeve ∅ 125 mm pc 7
05DM60000 Steel hose clamp ∅ 125 mm pc 20
05DM60L12 Half-hard duct ∅ 127 mm m 30
05DM60L12 Linear sleeve ∅ 125 mm pc 3
05DM13203 Inlet grid 200x150 pc 3
05DM12202 Plenum with 1 connection ∅ 125 mm pc 3
05DM12202 Calibration free rolling shutter pc 3
05DM13204 Inlet grid 300x150 pc 2
05DM12312 Plenum with 2 connections ∅ 125 mm pc 2
05DM10300 Calibration free rolling shutter pc 2
OUTLET
05DM91002 Telescopic outlet plenum pc 1
05DM28001 Outlet grid 800x200 mm pc 1
Mechanical ventilation + heating/cooling
VMC Clima
Air systems + ventilation
● Heating & cooling with ducted fan coil units
● Mechanical ventilation with an independent ventilation unit
● Autonomous air distribution ducts with independent regulation
IRIS CN
Altair
Advantages
● Fan-coil unit size selected according to heat demand
● Ventilation unit selected according to air exchange need
● Independent calibration
● 2 separate units work and are controlled independently
● Aesthetic: There is only one inlet air terminal in the room
Is that possible?
Mixed inlet air terminal Ventilation + Heating/ cooling
HEATING/COOLING inlets Ø 125 mm
with regulation rings
VENTILATION inlets Ø 75 mm
with calibration diaphgram
Mixed inlet air terminals
● Plenum in insulated PVC
● Pre-assembled connecting collars
● Wall mounted linear diffusers
● Ceiling mounted linear diffusers
● Double row swivel fins vents
Example
IRIS CN 600/800
ALTAIR CP 100
Example: 70m2
flat heating/cooling
Heating/ Cooling UFH ECOfloor G20 pipe spacing 10 ———> 3.600 €
System with Ecodry CNREC DC ———> 10.700 €
TOTAL* ——> 14.300 €
Heating/ Cooling UFH ECOfloor G20 pipe spacing 10 ———> 3.600 €
System Ventilation + battery ———> 8.174 €
TOTAL* ——> 11.774 €
Heating UFH ECOfloor G20 pipe spacing 15 ———> 3.100 €
System VMC Clima ———> 6.900 €
TOTAL* ——> 10.000 €
*without regulation
Altair SR 50
● One size with adjustment on 2-3 speed levels
● Ceramic regenerative exchanger with 77% efficiency
● Removable filter G3 (EN 779)
● Brushless axial fan Erp 2015
● Cycle air renewal flow rate 38 m3
/h - suitable for single dwellings up to 30 m2
Unit Energy class
Analog A
Electronic A
Altair SR 50: analog version
● 1 master with max. 3 slaves
● Manual mode: only extraction or only inlet
● Automatic mode: alternating extraction and inlet
SPEED
IN-OUT-AUTO
Altair SR 50: electronic version
● Two units: Opposite-directed operation
● Four units: 2 like-directed and 2 opposite-directed
IN-OUT-AUTO
Setting the cycle period according
to the outdoor/ indoor ∆t
Altair SR 50: electronic version
● The Master unit can be connected to up to 15 slave ones
● During sync, the slave units are set as opposite- or like-directed to the master
● Master and slave units are just electrically powered
● Master unit has a temperature probe for air passing through it
● Master unit is controlled remotely and the slave units follow it
Remote control
Altair SR 50: electronic version
● Setting of speed limit
● Operation mode: IN-OUT-AUTO
● Cycle control according to T measured by the probe
● Speed level: MIN-MED-MAX
● Night mode at extra low speed
● Control according to brightness and humidity both
for master and slave units
Tel. 0773 844051
Tel. 0773 848778
info@rossatogroup.com
www.rossatogroup.com
Follow us
ευχαριστω
!

Más contenido relacionado

La actualidad más candente

Heatwork catalogue english
Heatwork catalogue englishHeatwork catalogue english
Heatwork catalogue englishHeatwork
 
2015 x472 class 06- special building types
2015 x472 class 06- special building types2015 x472 class 06- special building types
2015 x472 class 06- special building typesmichaeljmack
 
2015 x472 class 04 - central and specialty
2015 x472 class 04 - central and specialty2015 x472 class 04 - central and specialty
2015 x472 class 04 - central and specialtymichaeljmack
 
Energy Efficiency Based on Sectors
Energy Efficiency Based on SectorsEnergy Efficiency Based on Sectors
Energy Efficiency Based on SectorsLeonardo ENERGY
 
Cool Roof Heat Resistant Tiles Ceramic Tiles from Thermatek India
Cool Roof Heat Resistant Tiles Ceramic Tiles from Thermatek IndiaCool Roof Heat Resistant Tiles Ceramic Tiles from Thermatek India
Cool Roof Heat Resistant Tiles Ceramic Tiles from Thermatek IndiaPranav Dixit
 
2015 x472 class 07 - system selection ii - pre-class
2015 x472 class 07 - system selection ii - pre-class2015 x472 class 07 - system selection ii - pre-class
2015 x472 class 07 - system selection ii - pre-classmichaeljmack
 
“STUDY AND FABRICATION OF OUTDOOR MIST/FOG COOLING SYSTEM THROUGH HIGH PRESSU...
“STUDY AND FABRICATION OF OUTDOOR MIST/FOG COOLING SYSTEM THROUGH HIGH PRESSU...“STUDY AND FABRICATION OF OUTDOOR MIST/FOG COOLING SYSTEM THROUGH HIGH PRESSU...
“STUDY AND FABRICATION OF OUTDOOR MIST/FOG COOLING SYSTEM THROUGH HIGH PRESSU...SHAILESH SHUKLA
 
2015 x472 class 03 - distribution systems
2015 x472 class 03 - distribution systems2015 x472 class 03 - distribution systems
2015 x472 class 03 - distribution systemsmichaeljmack
 
Walk in cooler & freezer cold room plant & refrigerated cold storage warehous...
Walk in cooler & freezer cold room plant & refrigerated cold storage warehous...Walk in cooler & freezer cold room plant & refrigerated cold storage warehous...
Walk in cooler & freezer cold room plant & refrigerated cold storage warehous...svfd1721
 
Presentation energy and comfort
Presentation  energy and comfort Presentation  energy and comfort
Presentation energy and comfort Ahmad Alshaghel
 
H2i Residential Cooling and Heating System Carried By Unique Indoor Comfort L...
H2i Residential Cooling and Heating System Carried By Unique Indoor Comfort L...H2i Residential Cooling and Heating System Carried By Unique Indoor Comfort L...
H2i Residential Cooling and Heating System Carried By Unique Indoor Comfort L...UniqueIndoorComfortLibertyville
 
Net Zero Building Enclosure Retrofits for Houses
Net Zero Building Enclosure Retrofits for HousesNet Zero Building Enclosure Retrofits for Houses
Net Zero Building Enclosure Retrofits for HousesRDH Building Science
 

La actualidad más candente (17)

TT_BlueBook
TT_BlueBookTT_BlueBook
TT_BlueBook
 
Heatwork catalogue english
Heatwork catalogue englishHeatwork catalogue english
Heatwork catalogue english
 
Free cooling guide 02 2013_46512
Free cooling guide 02 2013_46512Free cooling guide 02 2013_46512
Free cooling guide 02 2013_46512
 
2015 x472 class 06- special building types
2015 x472 class 06- special building types2015 x472 class 06- special building types
2015 x472 class 06- special building types
 
AMFA Company profile . !BS shw
AMFA Company profile . !BS shwAMFA Company profile . !BS shw
AMFA Company profile . !BS shw
 
2015 x472 class 04 - central and specialty
2015 x472 class 04 - central and specialty2015 x472 class 04 - central and specialty
2015 x472 class 04 - central and specialty
 
Energy Efficiency Based on Sectors
Energy Efficiency Based on SectorsEnergy Efficiency Based on Sectors
Energy Efficiency Based on Sectors
 
Energy%20Saving%20Equipment%20List
Energy%20Saving%20Equipment%20ListEnergy%20Saving%20Equipment%20List
Energy%20Saving%20Equipment%20List
 
Cool Roof Heat Resistant Tiles Ceramic Tiles from Thermatek India
Cool Roof Heat Resistant Tiles Ceramic Tiles from Thermatek IndiaCool Roof Heat Resistant Tiles Ceramic Tiles from Thermatek India
Cool Roof Heat Resistant Tiles Ceramic Tiles from Thermatek India
 
2015 x472 class 07 - system selection ii - pre-class
2015 x472 class 07 - system selection ii - pre-class2015 x472 class 07 - system selection ii - pre-class
2015 x472 class 07 - system selection ii - pre-class
 
Agnee e catalouge oven.
Agnee e catalouge oven.Agnee e catalouge oven.
Agnee e catalouge oven.
 
“STUDY AND FABRICATION OF OUTDOOR MIST/FOG COOLING SYSTEM THROUGH HIGH PRESSU...
“STUDY AND FABRICATION OF OUTDOOR MIST/FOG COOLING SYSTEM THROUGH HIGH PRESSU...“STUDY AND FABRICATION OF OUTDOOR MIST/FOG COOLING SYSTEM THROUGH HIGH PRESSU...
“STUDY AND FABRICATION OF OUTDOOR MIST/FOG COOLING SYSTEM THROUGH HIGH PRESSU...
 
2015 x472 class 03 - distribution systems
2015 x472 class 03 - distribution systems2015 x472 class 03 - distribution systems
2015 x472 class 03 - distribution systems
 
Walk in cooler & freezer cold room plant & refrigerated cold storage warehous...
Walk in cooler & freezer cold room plant & refrigerated cold storage warehous...Walk in cooler & freezer cold room plant & refrigerated cold storage warehous...
Walk in cooler & freezer cold room plant & refrigerated cold storage warehous...
 
Presentation energy and comfort
Presentation  energy and comfort Presentation  energy and comfort
Presentation energy and comfort
 
H2i Residential Cooling and Heating System Carried By Unique Indoor Comfort L...
H2i Residential Cooling and Heating System Carried By Unique Indoor Comfort L...H2i Residential Cooling and Heating System Carried By Unique Indoor Comfort L...
H2i Residential Cooling and Heating System Carried By Unique Indoor Comfort L...
 
Net Zero Building Enclosure Retrofits for Houses
Net Zero Building Enclosure Retrofits for HousesNet Zero Building Enclosure Retrofits for Houses
Net Zero Building Enclosure Retrofits for Houses
 

Similar a SEMINAR for Ventilation with heat recovery 2020

Empur preisliste 2014_2015
Empur preisliste 2014_2015Empur preisliste 2014_2015
Empur preisliste 2014_2015Dynamic444
 
Energy Efficiency Based on Sectors
Energy Efficiency Based on SectorsEnergy Efficiency Based on Sectors
Energy Efficiency Based on SectorsLeonardo ENERGY
 
Eta draco series reflow oven
Eta draco series reflow ovenEta draco series reflow oven
Eta draco series reflow ovenMark Tung
 
Eta draco series reflow oven
Eta draco series reflow ovenEta draco series reflow oven
Eta draco series reflow ovenLucy Xiao
 
Eta draco series reflow oven
Eta draco series reflow ovenEta draco series reflow oven
Eta draco series reflow ovenCarrie Zhang
 
Super inverter epcen08 114-catalogues_english (2)
Super inverter epcen08 114-catalogues_english (2)Super inverter epcen08 114-catalogues_english (2)
Super inverter epcen08 114-catalogues_english (2)Henry Hollands
 
Congres F-gassen 2015. Workshop 6: Praktijkcase: Koelen zonder koudemiddel
Congres F-gassen 2015. Workshop 6: Praktijkcase: Koelen zonder koudemiddelCongres F-gassen 2015. Workshop 6: Praktijkcase: Koelen zonder koudemiddel
Congres F-gassen 2015. Workshop 6: Praktijkcase: Koelen zonder koudemiddelRCCKL
 
Energy Conservation Building Code ECBC
Energy Conservation Building Code ECBCEnergy Conservation Building Code ECBC
Energy Conservation Building Code ECBCAmar Relan
 
Technical details of Energy Efficient HVAC System
Technical details of  Energy Efficient HVAC SystemTechnical details of  Energy Efficient HVAC System
Technical details of Energy Efficient HVAC Systemjayeshmahajan24
 
Sb compact dx_ver.1.0_en
Sb compact dx_ver.1.0_enSb compact dx_ver.1.0_en
Sb compact dx_ver.1.0_enYury Naumov
 
3 Tiger - INTRODUCTION
3 Tiger - INTRODUCTION3 Tiger - INTRODUCTION
3 Tiger - INTRODUCTIONTaha Iqbal
 
Uscatoare cu ciclu frigorifer CECCATO
Uscatoare cu ciclu frigorifer CECCATOUscatoare cu ciclu frigorifer CECCATO
Uscatoare cu ciclu frigorifer CECCATOColinGroup Craiova
 
Pimtas HDPE Fittings Supplier Sharjah.pptx
Pimtas HDPE Fittings Supplier Sharjah.pptxPimtas HDPE Fittings Supplier Sharjah.pptx
Pimtas HDPE Fittings Supplier Sharjah.pptxJinoVarghese14
 

Similar a SEMINAR for Ventilation with heat recovery 2020 (20)

Empur preisliste 2014_2015
Empur preisliste 2014_2015Empur preisliste 2014_2015
Empur preisliste 2014_2015
 
Thermovit
ThermovitThermovit
Thermovit
 
Energy Efficiency Based on Sectors
Energy Efficiency Based on SectorsEnergy Efficiency Based on Sectors
Energy Efficiency Based on Sectors
 
Eta draco series reflow oven
Eta draco series reflow ovenEta draco series reflow oven
Eta draco series reflow oven
 
Eta draco series reflow oven
Eta draco series reflow ovenEta draco series reflow oven
Eta draco series reflow oven
 
Eta draco series reflow oven
Eta draco series reflow ovenEta draco series reflow oven
Eta draco series reflow oven
 
Cooling_present(EN) - .pdf
Cooling_present(EN) - .pdfCooling_present(EN) - .pdf
Cooling_present(EN) - .pdf
 
Super inverter epcen08 114-catalogues_english (2)
Super inverter epcen08 114-catalogues_english (2)Super inverter epcen08 114-catalogues_english (2)
Super inverter epcen08 114-catalogues_english (2)
 
Cpg 2010
Cpg 2010Cpg 2010
Cpg 2010
 
Cool Roof Paint
Cool Roof PaintCool Roof Paint
Cool Roof Paint
 
Congres F-gassen 2015. Workshop 6: Praktijkcase: Koelen zonder koudemiddel
Congres F-gassen 2015. Workshop 6: Praktijkcase: Koelen zonder koudemiddelCongres F-gassen 2015. Workshop 6: Praktijkcase: Koelen zonder koudemiddel
Congres F-gassen 2015. Workshop 6: Praktijkcase: Koelen zonder koudemiddel
 
Energy Conservation Building Code ECBC
Energy Conservation Building Code ECBCEnergy Conservation Building Code ECBC
Energy Conservation Building Code ECBC
 
Technical details of Energy Efficient HVAC System
Technical details of  Energy Efficient HVAC SystemTechnical details of  Energy Efficient HVAC System
Technical details of Energy Efficient HVAC System
 
Sb compact dx_ver.1.0_en
Sb compact dx_ver.1.0_enSb compact dx_ver.1.0_en
Sb compact dx_ver.1.0_en
 
3 Tiger - INTRODUCTION
3 Tiger - INTRODUCTION3 Tiger - INTRODUCTION
3 Tiger - INTRODUCTION
 
SUNTEC DSA technical data_sp1000c_2014
SUNTEC DSA technical data_sp1000c_2014SUNTEC DSA technical data_sp1000c_2014
SUNTEC DSA technical data_sp1000c_2014
 
Uscatoare cu ciclu frigorifer CECCATO
Uscatoare cu ciclu frigorifer CECCATOUscatoare cu ciclu frigorifer CECCATO
Uscatoare cu ciclu frigorifer CECCATO
 
Pimtas HDPE Fittings Supplier Sharjah.pptx
Pimtas HDPE Fittings Supplier Sharjah.pptxPimtas HDPE Fittings Supplier Sharjah.pptx
Pimtas HDPE Fittings Supplier Sharjah.pptx
 
Powertech1
Powertech1Powertech1
Powertech1
 
Heat Pump Catalogue
Heat Pump CatalogueHeat Pump Catalogue
Heat Pump Catalogue
 

Último

Class 1 | NFPA 72 | Overview Fire Alarm System
Class 1 | NFPA 72 | Overview Fire Alarm SystemClass 1 | NFPA 72 | Overview Fire Alarm System
Class 1 | NFPA 72 | Overview Fire Alarm Systemirfanmechengr
 
UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)
UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)
UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)Dr SOUNDIRARAJ N
 
NO1 Certified Black Magic Specialist Expert Amil baba in Uae Dubai Abu Dhabi ...
NO1 Certified Black Magic Specialist Expert Amil baba in Uae Dubai Abu Dhabi ...NO1 Certified Black Magic Specialist Expert Amil baba in Uae Dubai Abu Dhabi ...
NO1 Certified Black Magic Specialist Expert Amil baba in Uae Dubai Abu Dhabi ...Amil Baba Dawood bangali
 
complete construction, environmental and economics information of biomass com...
complete construction, environmental and economics information of biomass com...complete construction, environmental and economics information of biomass com...
complete construction, environmental and economics information of biomass com...asadnawaz62
 
Sachpazis Costas: Geotechnical Engineering: A student's Perspective Introduction
Sachpazis Costas: Geotechnical Engineering: A student's Perspective IntroductionSachpazis Costas: Geotechnical Engineering: A student's Perspective Introduction
Sachpazis Costas: Geotechnical Engineering: A student's Perspective IntroductionDr.Costas Sachpazis
 
Indian Dairy Industry Present Status and.ppt
Indian Dairy Industry Present Status and.pptIndian Dairy Industry Present Status and.ppt
Indian Dairy Industry Present Status and.pptMadan Karki
 
Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...VICTOR MAESTRE RAMIREZ
 
Mine Environment II Lab_MI10448MI__________.pptx
Mine Environment II Lab_MI10448MI__________.pptxMine Environment II Lab_MI10448MI__________.pptx
Mine Environment II Lab_MI10448MI__________.pptxRomil Mishra
 
Introduction to Machine Learning Unit-3 for II MECH
Introduction to Machine Learning Unit-3 for II MECHIntroduction to Machine Learning Unit-3 for II MECH
Introduction to Machine Learning Unit-3 for II MECHC Sai Kiran
 
The SRE Report 2024 - Great Findings for the teams
The SRE Report 2024 - Great Findings for the teamsThe SRE Report 2024 - Great Findings for the teams
The SRE Report 2024 - Great Findings for the teamsDILIPKUMARMONDAL6
 
Industrial Safety Unit-IV workplace health and safety.ppt
Industrial Safety Unit-IV workplace health and safety.pptIndustrial Safety Unit-IV workplace health and safety.ppt
Industrial Safety Unit-IV workplace health and safety.pptNarmatha D
 
An experimental study in using natural admixture as an alternative for chemic...
An experimental study in using natural admixture as an alternative for chemic...An experimental study in using natural admixture as an alternative for chemic...
An experimental study in using natural admixture as an alternative for chemic...Chandu841456
 
Internet of things -Arshdeep Bahga .pptx
Internet of things -Arshdeep Bahga .pptxInternet of things -Arshdeep Bahga .pptx
Internet of things -Arshdeep Bahga .pptxVelmuruganTECE
 
Industrial Safety Unit-I SAFETY TERMINOLOGIES
Industrial Safety Unit-I SAFETY TERMINOLOGIESIndustrial Safety Unit-I SAFETY TERMINOLOGIES
Industrial Safety Unit-I SAFETY TERMINOLOGIESNarmatha D
 
System Simulation and Modelling with types and Event Scheduling
System Simulation and Modelling with types and Event SchedulingSystem Simulation and Modelling with types and Event Scheduling
System Simulation and Modelling with types and Event SchedulingBootNeck1
 
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort service
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort serviceGurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort service
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort servicejennyeacort
 
Input Output Management in Operating System
Input Output Management in Operating SystemInput Output Management in Operating System
Input Output Management in Operating SystemRashmi Bhat
 
Research Methodology for Engineering pdf
Research Methodology for Engineering pdfResearch Methodology for Engineering pdf
Research Methodology for Engineering pdfCaalaaAbdulkerim
 
THE SENDAI FRAMEWORK FOR DISASTER RISK REDUCTION
THE SENDAI FRAMEWORK FOR DISASTER RISK REDUCTIONTHE SENDAI FRAMEWORK FOR DISASTER RISK REDUCTION
THE SENDAI FRAMEWORK FOR DISASTER RISK REDUCTIONjhunlian
 

Último (20)

Class 1 | NFPA 72 | Overview Fire Alarm System
Class 1 | NFPA 72 | Overview Fire Alarm SystemClass 1 | NFPA 72 | Overview Fire Alarm System
Class 1 | NFPA 72 | Overview Fire Alarm System
 
UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)
UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)
UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)
 
NO1 Certified Black Magic Specialist Expert Amil baba in Uae Dubai Abu Dhabi ...
NO1 Certified Black Magic Specialist Expert Amil baba in Uae Dubai Abu Dhabi ...NO1 Certified Black Magic Specialist Expert Amil baba in Uae Dubai Abu Dhabi ...
NO1 Certified Black Magic Specialist Expert Amil baba in Uae Dubai Abu Dhabi ...
 
complete construction, environmental and economics information of biomass com...
complete construction, environmental and economics information of biomass com...complete construction, environmental and economics information of biomass com...
complete construction, environmental and economics information of biomass com...
 
Sachpazis Costas: Geotechnical Engineering: A student's Perspective Introduction
Sachpazis Costas: Geotechnical Engineering: A student's Perspective IntroductionSachpazis Costas: Geotechnical Engineering: A student's Perspective Introduction
Sachpazis Costas: Geotechnical Engineering: A student's Perspective Introduction
 
Indian Dairy Industry Present Status and.ppt
Indian Dairy Industry Present Status and.pptIndian Dairy Industry Present Status and.ppt
Indian Dairy Industry Present Status and.ppt
 
Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...
 
Mine Environment II Lab_MI10448MI__________.pptx
Mine Environment II Lab_MI10448MI__________.pptxMine Environment II Lab_MI10448MI__________.pptx
Mine Environment II Lab_MI10448MI__________.pptx
 
Introduction to Machine Learning Unit-3 for II MECH
Introduction to Machine Learning Unit-3 for II MECHIntroduction to Machine Learning Unit-3 for II MECH
Introduction to Machine Learning Unit-3 for II MECH
 
The SRE Report 2024 - Great Findings for the teams
The SRE Report 2024 - Great Findings for the teamsThe SRE Report 2024 - Great Findings for the teams
The SRE Report 2024 - Great Findings for the teams
 
Industrial Safety Unit-IV workplace health and safety.ppt
Industrial Safety Unit-IV workplace health and safety.pptIndustrial Safety Unit-IV workplace health and safety.ppt
Industrial Safety Unit-IV workplace health and safety.ppt
 
An experimental study in using natural admixture as an alternative for chemic...
An experimental study in using natural admixture as an alternative for chemic...An experimental study in using natural admixture as an alternative for chemic...
An experimental study in using natural admixture as an alternative for chemic...
 
Internet of things -Arshdeep Bahga .pptx
Internet of things -Arshdeep Bahga .pptxInternet of things -Arshdeep Bahga .pptx
Internet of things -Arshdeep Bahga .pptx
 
Industrial Safety Unit-I SAFETY TERMINOLOGIES
Industrial Safety Unit-I SAFETY TERMINOLOGIESIndustrial Safety Unit-I SAFETY TERMINOLOGIES
Industrial Safety Unit-I SAFETY TERMINOLOGIES
 
System Simulation and Modelling with types and Event Scheduling
System Simulation and Modelling with types and Event SchedulingSystem Simulation and Modelling with types and Event Scheduling
System Simulation and Modelling with types and Event Scheduling
 
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort service
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort serviceGurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort service
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort service
 
Input Output Management in Operating System
Input Output Management in Operating SystemInput Output Management in Operating System
Input Output Management in Operating System
 
Research Methodology for Engineering pdf
Research Methodology for Engineering pdfResearch Methodology for Engineering pdf
Research Methodology for Engineering pdf
 
Design and analysis of solar grass cutter.pdf
Design and analysis of solar grass cutter.pdfDesign and analysis of solar grass cutter.pdf
Design and analysis of solar grass cutter.pdf
 
THE SENDAI FRAMEWORK FOR DISASTER RISK REDUCTION
THE SENDAI FRAMEWORK FOR DISASTER RISK REDUCTIONTHE SENDAI FRAMEWORK FOR DISASTER RISK REDUCTION
THE SENDAI FRAMEWORK FOR DISASTER RISK REDUCTION
 

SEMINAR for Ventilation with heat recovery 2020

  • 2. Experience and innovation We have been working since more than 40 years in the HVAC and renewable energies field. We produce integrated and efficient systems for heating, cooling, domestic hot water, air treatment with heat recovery suitable for residential and commercial buildings (hotels, sport centers, wellness centers, etc)
  • 3. Integrated systems for energy savings Heating Cooling Dehumidification Solar Hot Water Ventilation Swimming pools
  • 4. Our watchwords Comfort according to the needs and expectations of the end customer, with the best ratio result/investment Simplicity and speed concerning installation, use and maintenance; easy and direct is also the relationship we build with our partners Energy savings exploiting renewable energies, reducing wastes, and using smart managing systems
  • 6. The advantages of an integrated system Unique supplier for the complete system Supply of all needed components Reduced installation costs No redundancy of components The same regulation logic in the whole system Tested and approved solutions Customized solutions
  • 7. Heat pumps ● Heating ● Cooling ● Domestic hot water ● Pools ● Air-water ● DHW
  • 8. Pompe di calore aria-acqua ● Riscaldamento ● Raffrescamento ● Acqua sanitaria ● Piscine Pellet and wood stoves and boilers ● Heating ● Domestic hot water ● Easy management ● TÜV certified
  • 9. Pompe di calore aria-acqua ● Riscaldamento ● Raffrescamento ● Acqua sanitaria ● Piscine Air treatment ● Air renewal ● Dehumidification ● Heat recovery ● Energy savings
  • 10. Fan coil units ● Heating ● Cooling ● Low thickness ● Wall / Ceiling ● False ceiling
  • 11. Radiant systems ● Heating ● Cooling ● Underfloor ● Wall / ceiling
  • 12. Solar systems ● Domestic hot water ● Heating ● Pools ● Drainback systems
  • 13. Thermoregulation ● Climatic ● Solar ● Smart control ● Remote control ● Energy savings
  • 14. Central heating ● Components ● Accessorie ● Smart management ● No wastes ● Better result
  • 15. IMPIANTI RADIANTI ROSSATO GROUP IMPIANTI RADIANTI ROSSATO GROUP Sustainability and Comfort ● Growing recognition across domestic consumer ● Growing demand for premium heating ● Stringent energy efficiency standards ● Development of digital home heating technologies ● Introduction of energy efficiency standards ● Increasing standard of living ● Strict government regulations Global Market Insights, 2019-2025
  • 16. IMPIANTI RADIANTI ROSSATO GROUP IMPIANTI RADIANTI ROSSATO GROUP Hotels & Offices Energy efficiency in hospitality & commercial buildings
  • 17. Hydronic underfloor heating Market: +7,5% in 2025 Global Market Insights, 2019-2025
  • 18. IMPIANTI RADIANTI ROSSATO GROUP IMPIANTI RADIANTI ROSSATO GROUP Radiant systems: why? ● Very high comfort ● Silent operation ● Design & décor freedom → More space for furniture ● Low power consumption ● Energy efficient operations → heat pumps
  • 19. IMPIANTI RADIANTI ROSSATO GROUP IMPIANTI RADIANTI ROSSATO GROUP Limits of radiant systems Available thickness of the floor: renovations ● Humidity control ● Performance with high outdoor temperature ● Economic investment ● Time to cool the room ● Hotel: sudden load variation (people coming in and out) Special applications only 3cm Ecofloor Tech Cooling Hotels / summer houses
  • 20. IMPIANTI RADIANTI ROSSATO GROUP IMPIANTI RADIANTI ROSSATO GROUP Program ● Special application with underfloor heating: Ecofloor Tech ● Air handling with radiant systems: Dehumidifiers ● Air renewal and heat recovery: Mechanical Ventilation ● Dehumidifier + heat recovery all-in-one: Ecodry CN REC ● Heating/cooling with fan coil units: Iris Pack ● Mechanical ventilation with heating/cooling: VMC Clima ● Smart Control: Caleon / Caleonbox ● Practical demonstration
  • 21. Low thickness radiant system ECOFLOOR TECH
  • 22. Low thickness ECOFLOOR TECH panels have been designed to get radiant floors with very low thickness: ● 30 mm with ECOFLOOR TECH 5 ● 35 mm with ECOFLOOR TECH 10 ● 45 mm with ECOFLOOR TECH 20 * with 10 mm of self-levelling screed on the knob
  • 23. Applications Applications: ● New houses ● Renovations ● Existing floors ● Premises with low available thickness Field of use: Heating Cooling
  • 24. ECOFLOOR TECH ● High density and low conductivity EPS insulation panel ● Footfall resistant HIPS 0,8 mm shell ● Knobs with pipe-holder profile ● Multiple 50 mm pipe spacing ● Male/Female perimeter interlocking system
  • 25. INSULATION PANEL Technical features Norm U.M. ECOFLOOR TECH 5 10 20 Insulation thickness - mm 5 10 20 Knob height - mm 15 Total height - mm 20 25 35 Declared thermal conductivity λD UNI EN 13163:13 W/mK 0,032 Actual thermal resistance Rλ,ins UNI EN 1264-3 m2 K/W 0,28 0,44 0,75 Compression strength at 10% with deformation σ10 UNI EN 826:13 Kpa 400 500 500
  • 26. INSULATION PANEL Features U.M. Value Outer diameter mm 14 Thickness mm 2 Water content l/m 0,079 Weight kg/m 0,075 Rolls m 150-280-500 ECOFLOOR TECH panel is combined with a PE-RT14x2 pipe. With it it it is possible to realize longer circuits compared to low thickness radiant systems using 10 mm tubes reducing the number of connections to the collector and therefore the costs of the system. LONGER CIRCUITS WITH PE-RT PIPE 14x2 mm
  • 27. Low thickness: Advantages ● Quick heating when starting (only 1 hr compared to 5 hr in traditional systems) ● Better response to thermoregulation ● High performance due to high conductivity and low thickness ● -3°C supply temperature compared to traditional systems ● Better heat diffusion because the self-levelling screed adheres well
  • 28. Faster construction sites ● Light and small panels ● Highly footfall resistant shell ● No need of anti-shrinkage nets ● Absence of joints and crack-resistant mesh ● Quick drying and start-up within a few days (4 days or as recommended) ● 40% Cost savings compared with a “dry” radiant system
  • 29. THICKNESS 1 - Baseboard 2 - Elastic filling 3 - PE edge insulation strip 4 - ECOFLOOR TECH 5 - Self-levelling screed 6 - PE-RT pipe 14x2 mm
  • 30. ECOFLOOR TECH Panel Hp (mm) Hm (mm) Ht (mm) ECOFLOOR TECH 5 20 10 30 ECOFLOOR TECH 10 25 10 35 ECOFLOOR TECH 20 35 10 45
  • 31. PRE-CONDITIONS Make sure that the following conditions are met before proceeding: ● Internal plaster is finished ● Structural height has been verified ● Electric and hydraulic sistema are finished ● Niches to place the manifolds have been made
  • 32. PRE-CONDITIONS The support surface must be: ● Flat ● Load-bearing ● Stable and compact ● Clean Measuring distance L (m) Allowed height difference d (mm) 1 3 4 9 10 12 15 15
  • 33. Possible support / subgrade ● Cement-based screed The substrate must be dimensionally stable and mechanically resistant according to the intended use of the floor. The surface must be cleaned of dust, dirt and grease and any cracks must be compensated to restore integrity and flatness. ● Lightened pre-screed It must be stable, compact and with good compressive strength. ● Existing ceramic or stone cladding Check, by tapping, that the covering is well fixed: any detached tiles must be removed and the flatness of the support must be restored. ● Wooden, PVC, linoleum, rubber or other cladding These coatings are not suitable to receive the ECOFLOOR TECH radiant system so they should be removed together with the adhesive residues up to the support layer. ● Acoustic insulation In this case, contact the technical office of the acoustic insulation manufacturer to know the characteristics of the insulation or the minimum thickness required for the self-levelling screed
  • 34. Insulation panels laying ● Observe all safety instructions ● Make sure that air temperature is between +5 and +30°C ● Shake the canister vigorously in order to completely mix the content ● Use a dispensing gun and screw the adhesive canister onto it ● To optimize the foam, moisten the substrate with water mist. ● Proceed with the application of the adhesive using the dispensing gun
  • 35. Insulation panels laying ● Apply the adhesive on panel lower surface taking care to make curbs ● Immediately press the panels down firmly ● After hardening, remove any excess foam
  • 36. Distribution manifold ● Manifold 1” e 1”1/4 for radiant systems (as per UNI EN 1264) ● Optimized module geometry to reduce pressure drops ● Structure in fibreglass-reinforced polyamide anti-condensation ● Modular manifold 2-18 outputs ● Horizontal and vertical installation
  • 37. Distribution manifold MATERIALS Nylon 6,6 glass-fibre reinforced at 30%, hydrolysis resistant Stainless steel Peroxide EPDM TECHNICAL FEATURES Shipping/storage temperature -10 ÷ 80 °C Continuous operation temperature at 2 bar 2°C ÷ 100°C Maximum operation temperature 120°C Operation pressure at ambient temperature 0 bar ÷ 8 bar Bursting pressure > 40 bar
  • 38. Distribution manifold ● Flow meter valve for regulation 0-5 l/min ● Air vent ● Thermometer ● Connection for system load/ unload Supply module
  • 39. Distribution manifold ● Shut-off valve with manual knob ready for electro-thermic actuators ● Air vent ● Thermometer ● Connection for system load/ unload Return module
  • 40. Distribution manifold ● Remove the plugs from the manifold couplings ● Cut the pipes perpendicular to the axis at a distance of 30-39 mm cm from the coupling (depending on the pipe) ● Prepare the end of the tube with countersink/calibrator ● Mark the bottom of the stroke (variable according to pipe diameter and type) Required accessories are: ● cutter ● countersink/calibrator Sliding quick push-in connectors
  • 41. Manifold cabinet DIMENSIONS OF CABINET (mm) Length (A) 400 600 850 1000 1200 Height (B) 650 Depth (C) 110 DIMENSIONS OF DOOR (mm) Width (I) 450 650 900 1050 1250 Height (H) 650
  • 43. Planning: Heating load Design and construction of a radiant system depends on following data: ● Available surface ● Customer needs ● Building and architectural requirements ● Building’s heating / cooling load Without heating / cooling load information, the systems are sized with a fixed heating load of 70 W/m2 .
  • 44. Planning: Manifold position ● Manifold position ● Number of manifolds (also depending on control system) LR =AF/ T AF =100 m2 T= 0,1 m Lr=100/0,1=1000 m Medium circuits length LC =75 m N° circuits 1000/75= 13 N° outlets = 13 + term. + dehum. Prefer a barycentric position
  • 45. Planning: Manifold position The manifold position depends on the cabinet size, too
  • 47. Air handling In accordance with EN 1264 the cooling flow temperature must not be more than 1 K lower than the dew temperature calculated for the ambient conditions. (Example room temperature of 26°C, relative humidity 50%: dew temperature is 14.8°C and flow temperature cannot be lower than 13.8°C). Supply temperature according to R.H. Room temperature (° C) Relative humidity % Dew temperature Supply temperature 26 °C 55% 16,3 °C 15,3 °C 26 °C 60% 17,6 °C 16,6 °C 27 °C 55% 17,2 °C 16,2 °C 27 °C 60% 18,6 °C 17,6 °C Low R.H. values allow to obtain higher performances from the radiant system but require more energy
  • 48. Air handling The surface temperature must always be higher than the dew temperature. medium air temperature difference ∆ΘH nominal temperature difference
  • 49. Air handling ● Set the flow temperature to have a surface temperature 2°C higher than the corresponding dew temperature ● Size the dehumidifier for a dehumidification capacity equal to the latent design load ● Use a control system that starts the dehumidifier when the design R.H. threshold value is exceeded ● Use a control system that raises the supply temperature to the radiant system when the design R.H. threshold value is exceeded. Take these precautions to prevent surface condensation
  • 50. Dehumidifiers ● Direct expansion systems with hydronic integration ● Air handling with sole circulation ● Neutral or cooled air supply ● Ductable or built-in version ● Management through system climate control
  • 51. Dehumidifiers Ecodry CN Ecodry IN Ducted system for several rooms Built-in unit for one single room Model Dehumidification l/g T 26°C R.H. 65% Water 15°C Absorbed power W Air flow m3 /h Operation range °C Cooling power W CN+ 300 20,8 320 250 10÷30 - CN+ 300 DC 20,8 320 250 10÷30 1.240 CN+ 600 48,2 750 600 10÷30 - CN+ 600 DC 48,2 750 600 10÷30 3.230
  • 53. Dehumidifiers Model Wall Wall Ceiling Ceiling Ceiling Ceiling IN+300 IN+300 DC CN+300 CN+300 DC CN+600 CN+600 DC Dehumidification capacity l/day 20,8 48 Cooling capacity W - 1240 - 1240 - 3230 Absorbed power W 320 700 Absorbed current A 2,15 5 Electrical supply V/ph/Hz 230/1+N/50 Tolerance of electrical supply % +/- 10 Air flow m3 /h 250 600 Useful static head Pa Nominal water flow l/h 150 500 Water pressure drop kPa 15 30 29 Limit storage temperature °C -10/ +43 Limit storage humidity % 90 Sound pressure level db (A) 38 43 Weight kg 34 36 35 37 52 55
  • 54. Dehumidifiers HYDRAULIC AERAULIC direct supply with dedicated pump distribution with ventilation system
  • 56. Altair units: overview Which unit? Altair CP 100/200 Altair HR 301/501 Altair VR 301/601 Altair HRM 8-15-18-26-40
  • 57. Main features High energy class (A or B) Low consumption fans (according to ErP 2015-2018) High efficient heat recovery (up to 90%) Filtering (class F7 filters for supply air and G4 for extraction air) By pass (automatic bypass for free-cooling and free-heating)
  • 58. Altair VR 401-601 UNIT CONTROL ENERGY CLASS ALTAIR VR 401 CTR B ALTAIR VR 601 B ALTAIR VRX 401 CTRX B ALTAIR VRX 601 A ● Vertical unit ● Size 400 - 600 m3 /h ● Static propylene heat exchanger in counterflow ● Total by-pass 100% ● Fans with electronic speed control ● Self-supporting structure in 25 mm thick sandwich panels ● Opening doors on the front for easy maintenance A drain pipe with a syphon and a minimum slope of 3% must always be provided in order to prevent the condensation water from becoming stationary.
  • 59. Altair VR 401-601 Fresh air Extraction Inlet Outlet Outlet Outlet Fresh air Fresh air Outlet Inlet Fresh air Outlet Inlet Fresh air Outlet Fresh air Fresh air Outlet Outlet Inlet Inlet Extraction Extraction Extraction Outlet Fresh air
  • 60. Altair HR 310-501 UNIT CONTROL ENERGY CLASS ALTAIR HR 301 CTR B ALTAIR HR 501 B ALTAIR HRX 301 CTRX A ALTAIR HRX 501 B ● Horizontal unit ● Size 330 - 460 m3 /h ● Static aluminium heat exchanger in counterflow ● Total by-pass 100% ● Fans with electronic speed control ● Double brushed sandwich aluzink structure with 25 mm insulation ● Opening doors on the side for easy maintenance A drain pipe with a syphon and a minimum slope of 3% must always be provided in order to prevent the condensation water from becoming stationary.
  • 61. Altair CP 100 - 200 UNIT CONTROL ENERGY CLASS ALTAIR CP 100 CTR A ALTAIR CP 200 A+ ALTAIR CPX 100 CTRX A ALTAIR CPX 200 A+ ● Horizontal unit ● Size 120 - 460 m3 /h ● Static PP heat exchanger in counterflow ● Partial by-pass 80% ● Fans with electronic speed control A drain pipe with a syphon and a minimum slope of 3% must always be provided in order to prevent the condensation water from becoming stationary.
  • 62. How to choose 0 m3 /h 90 m3 /h 200 m3 /h 300 m3 /h 70 m2 150 m2 220 m2 CP100/200 CP200/ HR301/ VR401 HR501/ VR601 DATA REFERRED TO MEDIUM SPEED OPERATION
  • 64. Standard control CTR ALARMS SPEED BY PASS STATUS Frost protection the heat exchanger is automatically protected from frost by temporary unbalancing of the flow rates reducing/stopping the outdoor flow rate going inside: with outlet air temperature below 3°C.
  • 65. Standard control CTR ALARMS Fans stop Dirty filters (signalled by pressure switch or hour counter) ALARMS
  • 66. Standard control CTR SPEED Speed control LED ON: Speed 1-2-3 LED OFF: Unit off
  • 67. Standard control CTR BY PASS STATUS ● Fixed Led = Summer → by-pass off with outdoor T > inlet T + 2°C ● Led off = Winter → by-pass off with inlet T > outdoor T + 2°C ● Blinking Led → automatic (free-cooling/heating) Tmin-Tmax 15°C - 22°C
  • 68. Advanced control CTRX ICON FOR WINDOW CHANGE / SCROLLING / OK After 1 minute of inactivity the screen switches to stand-by mode and flashes in case of alarm!
  • 69. Advanced control CTRX Programming from 1 min to 4 h with Vmax and priority over the program. ● off: device shutdown ● xxx%: Continuously adjustable speed between a minimum and a maximum with 5% steps ● Auto: speed management based on the control of a sensor (CO2 , CO2 -VOC, relative humidity RH) ● Clock: speed management according to the weekly chronoprogram Booster
  • 70. Advanced control CTRX ● Daily setting (Mon-Fri Sat-Sun) ● Speed setting to 8 time slots with a minimum resolution of 30 minutes ● Setting on three speed levels ● The Timetable offers an overview of the week days over 24 hours WEEK CHRONOPROGRAM
  • 71. Advanced control CTRX ● Summer → by-pass off with outdoor T > inlet T + 2°C ● Winter → by-pass off with inlet T > outdoor T + 2°C ● Mid-seasons / automatic → automatic by-pass (free-cooling/heating) BY-PASS
  • 72. Advanced control CTRX ● CO2 sensor: auto min - auto max 0-1980 ppm ● VOC/CO2 sensor: auto min - auto max 20-2000 ppm ● Humidity sensor: auto min - auto max% Room sensors
  • 73. Advanced control CTRX ● with modulating PWM signal ● switching on with outlet air below 3°C ● 100% switching on with outlet air at 1°C (values can be changed on request) Pre-heating on Pre-heating off
  • 75. Air distribution system ● Insulated distribution plenum for inlet/outlet ● Flow rates from 250 m3 /h to 480 m3 /h ● Pipe connection already installed in the plenum Adjusting rings Pre-cut calibration rings to remove by pressure
  • 76. Air distribution system ● Double-walled food-grade polyethylene pipe, corrugated outside and smooth inside ○ outer layer → resistant to chemical aggression of concrete and flame resistant ○ inner layer → smooth antistatic and antibacterial HDPE film ● Diameter 75/63 mm max 35 m3 /h ● Diameter 90/76 mm max 60 m3 /h ● Radius of curvature 7 x DN ● Crushing resistance 450 N (with 5% outside diameter deformation) ● Pre-insulated version with 3 mm layer of grey colour for heating/cooling
  • 77. Silent operation The "single duct for single room" system prevents the cross-talking effect and guarantees silence and privacy. Additional precautions ● Silencers in the duct ● Low air speed in the ducts (max 3,5 m/s) ● Vibration dampers ● Acoustic insulation of the technical room
  • 78. Air diffusion indoor PVC grids with slits or swivelling flaps Ventilation valves Linear air vents Galvanized sheet metal adapters with 2/3 reversible connections on rear side face Adapter for DN125 valve with 2 caps
  • 79. Air diffusion indoor Ventilation principle Temperature difference between inlet air and air in the breathing zone ∆t=tA -tim (°C) Ventilation efficiency Mixing ventilation Heating ∆t < -5 -2 < ∆t < -5 -2 < ∆t < 0 Cooling 0.4÷0.7 0.8 0.9 Cooling 0.9÷1.0 Mixing ventilation Heating ∆t < 0 Cooling 0 < ∆t < 5 ∆t > 5 1.0 Cooling 0.9÷1.0 0.9 Displacement ventilation Heating ∆t < -2 -2 < ∆t < 0 Cooling 0 < ∆t 0.2÷0.7 0.7÷0.9 Cooling 1.2÷1.4
  • 80. Outdoor terminal units Wall grid for air outlet/ inlet D125 - D160/180 - D200 complete with internal insect screen Flush wall terminal unit for air outlet/ inlet in white painted galvanized steel D125 - D160/180 - D200 frame coarse insect filter customizable screen* flat screen *The screen can be customized with the same material of the wall finishing
  • 81. Outdoor terminal units: where? ● Far from pollutant source ● Shielded from prevailing winds ● Minimum 3 m higher than the street level (UNI 10339) ● Not in basement hopper nor aerated wasps to avoid radon contaminations ● 2 m far from air expulsion to avoid a short circuit (UNI 10339) ● Not too close to other buildings to avoid noise
  • 83. The customer needs What does the customer need? ● Only mechanical ventilation ● Mechanical ventilation and dehumidifying ● Post-heating / cooling ● Ventilation and heating/cooling Choose the type of system
  • 84. The building site needs What, Where and How can be made? ● Horizontal or Vertical unit ● The technical room where the unit will be installed ● Space for ventilation ducts ● Position of the plenum ● Position and kind of ventilation terminal units ● Position of outdoor terminal units Collect the info and send them to our technical dpt
  • 85. Position of the ventilation unit PAY ATTENTION TO THE RESPECT SPACES AND THE POSITION OF THE INSPECTION PANEL!!! ALTAIR VR: FRONT ALTAIR HR: SIDE ALTAIR CP: BOTTOM
  • 86. Space for ventilation ducts Underfloor False ceiling Wall
  • 87. Position of the plenum Technical room Technical room False ceiling
  • 88. Position of grids and valves Wall Ceiling / false ceiling
  • 89. Project Rossato draws the system layout ● The air exchange flows are defined ● The ventilation unit is sized ● The air system is sized ● The system layout is drawn ● The material are listed ● The system calibration settings are defined
  • 91. Installation ● Check that the project corresponds to the building site ● Install all components following the project ● Calibrate air flow through regulation rings on the collector ● Check air flows with measurement tools ● Start the system up
  • 92. Example Energy upgrading of a residential dwelling ● Thermal insulation ● Solar thermal + condensing boiler ● Photovoltaic ● New windows ● Mechanical ventilation
  • 93. Example 75 m2 - 200 m3 ca minimum exchange rate 100 m3 /h 4 people 140 m3 /h → 35 m3 /h for each person
  • 95. Example The unit is installed under the roof If the unit is placed in a not-heated room, we recommend to insulate the distribution ducts to prevent energy loss from and towards the exchanger
  • 96. Maintenance Yearly ordinary maintenance ● Clean the filter with running water (2000 h) ● Clean the condensate tray ● Clean the exchanger Extra ordinary maintenance ● Clean the air ducts with brushes, air brushes or vacuum cleaners ● Use sanitizing products
  • 97. Dehumidifier + air renewal Ecodry CN REC
  • 98. Ecodry CN REC Isothermal and DC version: supply 15°C Direct expansion circuit Pre/ post-treatment batteries Air or water condensation for DC version
  • 99. Ecodry CN REC IDRO version: supply 10°C ECODRY CNREC IDRO units have no refrigeration circuit and must be supplied with cooled or heated water: battery + 3 ways valve.
  • 100. Air renewal + circulation Air renewal + dehumidifier / cooling / heating as set exhaust air expulsion outdoor (max 130 m3 /h) outdoor fresh air inlet (max 130 m3 /h) exhaust air extraction (max 130 m3 /h) air supply indoor (260 m3 /h) indoor air suction (max 260 m3 /h)
  • 101. Air circulation indoor air suction supply air indoor Circulation + dehumidification / cooling / heating as set 260m3 /h 260m3 /h
  • 102. Air renewal 0 - MIN - MED - MAX Winter - mid seasons 0 - MIN - MED - MAX 0 - MIN - MED - MAX 0 - MIN - MED - MAX
  • 103. Ecodry CN REC: functioning 1 2 3 4 5 Renewal Outlet Inlet Circulation Extraction
  • 104. Ecodry CN REC: example
  • 105. heating/ cooling with fan coil units Training Iris Pack
  • 106. Iris Pack: components Iris CN 600-800 Plenum + air ducts + valves Ducted fan coil unit + air distribution system → ducts with the same diameter
  • 107. Applications Applications: ● Heating with boilers and heat pumps ● Cooling with heat pumps and chillers ● Residential and commercial dwellings ● Integration for heating/cooling systems in existing systems Field of use: Heating Cooling
  • 108. Main features ● Easy integration in the architecture ● No visible components ● Low air speed ● Silent operation ● Complete system with all accessories ● Easy air flow balancing ● Easy and quick installation ● Uniform air diffusion Comfort and aesthetic Complete and ready system
  • 109. IRIS CN 800 ● Reduced energy consumption ● Brushless fans with variable speed control ● Silent operation ● Small dimensions (only 275 mm thickness) ● Invisible installation in false ceiling Ducted fan coil unit
  • 110. Components ● Inlet plenum designed to ensure balanced air distribution at low speed. ● 9 pre-cut connections: 7 on front and 2 on side ● All connections have the same diameter Ø 125 mm. The number of ducts must vary according to the air flow rate in order to maintain the speed below 4 m/s. Inlet plenum
  • 111. Components ● Designed to to adapt to different architectural requirements ● pre-cut connections on the bottom and on the side ● Telescopic extension to adapt the plenum to different false ceiling heights Outlet plenum The grid can be placed: ● directly on the unit’s plenum ● on the unit’s plenum through the telescopic extension ● on a second plenum a bit far from the unit through flexible ducts ø200mm
  • 112. Components ● Half-hard duct in expanded cross-linked PE ● Antibacterial and anti-mould treatment ● Resistant and insulated ● Less pressure drops Outlet air flow grid Inlet air flow grid Linear air vent Accessories
  • 113. Components Features Rotation speed M.U. IRIS CN 600 IRIS CN 800 Air flow (open-mouth unit) H m3 /h 1.350 1.450 M m3 /h 1.080 1.175 L m3 /h 783 870 Total cooling power (Inlet air 26°C d.b. R.H.55% - water 7-12°C) H W 6.973 10.345 M W 6.251 9.332 L W 5.313 8.017 Sensible cooling power (Inlet air 26°C d.b. R.H.55% - water 7-12°C) H W 4.910 6.844 M W 4.259 5.986 L W 3.460 4.929 Water flow in cooling mode M l/h 1.075 1.605 Pressure drop in cooling M KPa 30,1 32,9 Heat output H W 8.971 11.967 M W 7.867 10.558 L W 6.490 8.804 Water flow in heating mode (Inlet air 20 °C d.b. - water 50-45°C) M l/h 1.121 1.674 Pressure drop in heating (Inlet air 20 °C d.b. - water 50-45°C) M KPa 27,8 30,3
  • 114. Components Electrical data Rotation speed M.U. IRIS CN 600 IRIS CN 800 Power Supply V/PH/Hz 230/1/50 Current consumption W 290 290 Absorbed current A 1,3 Sound levels H dB(A) 49 50 M dB(A) 43 44 L dB(A) 34 35
  • 115. Example ● Apartment 75 m2 ● Installation in false ceiling ● Outlet in the ceiling under the unit ● Heat demand: 5.900W (ca.80 W/m2 ) IRIS CN 600 at medium speed with supply temperature 45°C 7 outlets from the front plenum Room Demand W Ducts nr Air flow m3 /h Grids LR 2670 3 420 1 with 2 ducts + 1 with 1 duct L 1780 2 280 1 with 2 ducts K 890 1 140 1 with 1 duct WC 890 1 140 1 with 1 duct
  • 116. Example LIST OF MATERIALS IRIS PACK WITH IRIS CN 600 Code Description M.U. Quantity 01VC02001 IRIS CN 600 pc 1 05DM91001 Inlet plenum pc 1 05DM60M12 Flanged sleeve ∅ 125 mm pc 7 05DM60000 Steel hose clamp ∅ 125 mm pc 20 05DM60L12 Half-hard duct ∅ 127 mm m 30 05DM60L12 Linear sleeve ∅ 125 mm pc 3 05DM13203 Inlet grid 200x150 pc 3 05DM12202 Plenum with 1 connection ∅ 125 mm pc 3 05DM12202 Calibration free rolling shutter pc 3 05DM13204 Inlet grid 300x150 pc 2 05DM12312 Plenum with 2 connections ∅ 125 mm pc 2 05DM10300 Calibration free rolling shutter pc 2 OUTLET 05DM91002 Telescopic outlet plenum pc 1 05DM28001 Outlet grid 800x200 mm pc 1
  • 117. Mechanical ventilation + heating/cooling VMC Clima
  • 118. Air systems + ventilation ● Heating & cooling with ducted fan coil units ● Mechanical ventilation with an independent ventilation unit ● Autonomous air distribution ducts with independent regulation IRIS CN Altair
  • 119. Advantages ● Fan-coil unit size selected according to heat demand ● Ventilation unit selected according to air exchange need ● Independent calibration ● 2 separate units work and are controlled independently ● Aesthetic: There is only one inlet air terminal in the room
  • 120. Is that possible? Mixed inlet air terminal Ventilation + Heating/ cooling HEATING/COOLING inlets Ø 125 mm with regulation rings VENTILATION inlets Ø 75 mm with calibration diaphgram
  • 121. Mixed inlet air terminals ● Plenum in insulated PVC ● Pre-assembled connecting collars ● Wall mounted linear diffusers ● Ceiling mounted linear diffusers ● Double row swivel fins vents
  • 123. Example: 70m2 flat heating/cooling Heating/ Cooling UFH ECOfloor G20 pipe spacing 10 ———> 3.600 € System with Ecodry CNREC DC ———> 10.700 € TOTAL* ——> 14.300 € Heating/ Cooling UFH ECOfloor G20 pipe spacing 10 ———> 3.600 € System Ventilation + battery ———> 8.174 € TOTAL* ——> 11.774 € Heating UFH ECOfloor G20 pipe spacing 15 ———> 3.100 € System VMC Clima ———> 6.900 € TOTAL* ——> 10.000 € *without regulation
  • 124. Altair SR 50 ● One size with adjustment on 2-3 speed levels ● Ceramic regenerative exchanger with 77% efficiency ● Removable filter G3 (EN 779) ● Brushless axial fan Erp 2015 ● Cycle air renewal flow rate 38 m3 /h - suitable for single dwellings up to 30 m2 Unit Energy class Analog A Electronic A
  • 125. Altair SR 50: analog version ● 1 master with max. 3 slaves ● Manual mode: only extraction or only inlet ● Automatic mode: alternating extraction and inlet SPEED IN-OUT-AUTO
  • 126. Altair SR 50: electronic version ● Two units: Opposite-directed operation ● Four units: 2 like-directed and 2 opposite-directed IN-OUT-AUTO Setting the cycle period according to the outdoor/ indoor ∆t
  • 127. Altair SR 50: electronic version ● The Master unit can be connected to up to 15 slave ones ● During sync, the slave units are set as opposite- or like-directed to the master ● Master and slave units are just electrically powered ● Master unit has a temperature probe for air passing through it ● Master unit is controlled remotely and the slave units follow it Remote control
  • 128. Altair SR 50: electronic version ● Setting of speed limit ● Operation mode: IN-OUT-AUTO ● Cycle control according to T measured by the probe ● Speed level: MIN-MED-MAX ● Night mode at extra low speed ● Control according to brightness and humidity both for master and slave units
  • 129. Tel. 0773 844051 Tel. 0773 848778 info@rossatogroup.com www.rossatogroup.com Follow us ευχαριστω !