MPFIM4, Residual Current Devices for earth leakage detection. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.
1. MPFIM4
www.meba.net
Residual Current
Circuit Breaker
128
MPFIM4 Residual Current Circuit Breaker
Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: MPFIM4
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 4P
Specification:
MPFIM4, Residual CurrentDevices for earthleakage detection. It is tobe used in association with miniaturecircuit breakers, itsfunction
is to detectearth leakage currentand open the connected circuit to protect people and equipment, major usedin industrial app lication.
These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.
Technical parameter:
Electromagnetic and Electronic type
35mm wide for 4 pole Din Rail installation.
Standsrd: IEC1008/EN61008
Rated Voltage(Un): 2pole, 230V AC
Rated Current(In): 25, 40, 63A
Rated residual operating current(In): 30, 100, 300, 500mA
Rated residual non-operating current(Ino): 0.5 In
Residual current off-time: 0.1s
Minimum value of rated breaking capacity(lm): 630A
Rated conditional short-circuit capacity (lnc): 6KA
Dimensions:
77 0.8
35.60.3
44.5
66
5.5
45
830.8
35.5 0.3
72
66.30.3
36
2. CF-362 Residual Current Circuit Breaker
www.meba.net
Residual Current
Circuit Breaker
Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: CF-362
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P
Specification:
CF-362, Residual CurrentDevices for earthleakage detection. Itis to beused in associationwith miniature circuitbreakers, its function
is todetect earth leakage current and open theconnected circuit to protect people andequipment, major used in industrial application.
These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.
Technical parameter:
Electromagnetic and Electronic type
35mm wide for 2 pole Din Rail installation.
Standsrd: IEC1008/EN61008
Rated Voltage(Un): 2pole, 230V AC
Rated Current(In): 25, 40, 63A
Rated residual operating current(I n): 30, 100, 300, 500mA
Rated residual non-operating current(I no): 0.5 I n
Residual current off-time: 0.1s
Minimum value of rated breaking capacity(lm): 630A
Rated conditional short-circuit capacity (lnc): 6KA
CF-364 Residual Current Circuit Breaker
Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: CF-364
Type: Residual Current Circuit Breaker or Residual Current Device)
Poles Number: 4P
Specification:
CF-364, Residual CurrentDevices for earthleakage detection. Itis to beused in associationwith miniature circuitbreakers, its function
is to detect earth leakage currentand open theconnected circuit toprotect people andequipment , major used in industrial application.
These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.
Technical parameter:
Electromagnetic and Electronic type
70mm wide for 4 pole Din Rail installation.
Standsrd: IEC1008/EN61008
Rated Voltage(Un): 4pole, 400V AC
Rated Current(In): 25, 40, 63A
Rated residual operating current(I n): 30, 100, 300, 500mA
Rated residual non-operating current(I no): 0.5 I n
Residual current off-time: 0.1s
Minimum value of rated breaking capacity(lm): 630A
Rated conditional short-circuit capacity (lnc): 6KA
CF-362 CF-364
129
3. www.meba.net
Specification:
Technical parameter:
Specification:
Technical parameter:
Residual Current
Circuit Breaker
CF-462 Residual Current Circuit Breaker
Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: CF-462
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P
CF-462, Residual CurrentDevices for earthleakage detection. It is to beused in associationwith miniature circuitbreakers, its function
is to detect earth leakage curre nt and open the connected circuit to protect peopleand equipment, majorused in industrialapplication.
These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.
Electromagnetic and Electronic type
35mm wide for 2 pole Din Rail installation.
Standsrd: IEC1008/EN61008
Rated Voltage(Un): 2pole, 230V AC
Rated Current(In): 25, 40, 63A
Rated residual operating current(I n): 30, 100, 300, 500mA
Rated residual non-operating current(I no): 0.5 I n
Residual current off-time: 0.1s
Minimum value of rated breaking capacity(lm): 630A
Rated conditional short-circuit capacity (lnc): 6KA
CF-464 Residual Current Circuit Breaker
Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: CF-464
Type: Residual Current Circuit Breaker or Residual Current Device)
Poles Number: 4P
CF-464, Residual CurrentDevices for earthleakage detection. Itis to beused in associationwith miniature circuitbreakers, its function
is to detect earth leakage current andopen the connectedcircuit to protectpeople and equipment, major used in industri al application.
These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.
Electromagnetic and Electronic type
70mm wide for 4 pole Din Rail installation.
Standsrd: IEC1008/EN61008
Rated Voltage(Un): 4pole, 400V AC
Rated Current(In): 25, 40, 63A
Rated residual operating current(I n): 30, 100, 300, 500mA
Rated residual non-operating current(I no): 0.5 I n
Residual current off-time: 0.1s
Minimum value of rated breaking capacity(lm): 630A
Rated conditional short-circuit capacity (lnc): 6KA
CF-462 CF-464
130
4. www.meba.net
Residual Current
Circuit Breaker
DZ30L-32 Residual Current Circuit Breaker
Specification:
Technical parameter:
Residual current circuit breaker with overload protection(RCBO)
Brand Name: Meba
Model Number: DZ30L-32
Type: Residual current circuit breaker with overload protection(RCBO)
Poles Number: DPN
DZ30L-32(DPN), combination by mini circuit breaker and leakage. Which protect human from the fault of electric because of over-
current, short circuit, earth fault current. It is self-protecting up to a maximum short-circuit current 63A. All breakingcapacities comply
with Standard IEC/EN 61009.
Residual current device with overcurrent protection
Combine in residual current device function and MCB over-current protection function
Short circuit capacity: 3KA
Rated current(A): 6, 16, 20, 25, 32A
Rated leakage operating current(mA): 30, 100, 300mA
AC types, B-C characteristic
Modular Din Rail products 35mm.
DZ47LE-63-2P Residual Current Circuit Breaker
Specification:
Technical parameter:
Residual current circuit breaker with overload protection(RCBO)
Brand Name: Meba
Model Number: DZ47LE-63
Type: Residual current circuit breaker with overload protection(RCBO)
Poles Number: 2 pole MCB + ELCB
DZ47LE-63 2Pole, combination by mini circuit breaker and leakage. Which protect human from the fault of electric because of over-
current, short circuit, earth fault current. It is self-protecting up toa maximum short-circuit current 63A. All breaking capacitiescomply
with Standard IEC/EN 61009.
Residual current device with overcurrent protection
Combine in residual current device function and MCB over-current protection function
Short circuit capacity: 6KA
Rated current(A): 6,16,20,25,32,40,50,63A
Rated leakage operating current(mA): 30,100,300mA
AC types, B-C characteristic
Modular Din Rail products 35mm.
131
DZ30L-32 DZ47LE-63-2P
5. M
www.meba.net
Specification:
Technical parameter:
Residual Current
Circuit Breaker
DZ47LE-63-4P Residual Current Circuit Breaker
Residual current circuit breaker with overload protection(RCBO)
Brand Name: Meba
Model Number: DZ47LE-63
Type: Residual current circuit breaker with overload protection(RCBO)
Poles Number: 4 pole MCB + ELCB
DZ47LE-63 4Pole, combination by mini circuit breaker and leakage. Which protect human from the fault of electric because of over-
current, short circuit, earth fault current. It is self-protecting up to a maximum short-circuit current 63A. All breakingcapacities comply
with Standard IEC/EN 61009.
Residual current device with overcurrent protection
Combine in residual current device function and MCB over-current protection function
Short circuit capacity: 6KA
Rated current(A): 6, 16, 20, 25, 32, 40, 50, 63A
Rated leakage operating current(mA): 30, 100, 300mA
AC types, B-C characteristic
Modular Din Rail products 35mm.
132
DZ47LE-63-4P
M Residual Current Circuit Breaker
Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: M
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P
Specification:
M series Residual Cur rent Devices for earth leakage detection. Itis to beused in association with miniature circuit breakers, its function
is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.
These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.
Electromagnetic and Electronic type
35mm wide for 2 pole Din Rail installation.
Standsrd: IEC1008/EN61008
Rated Voltage(Un): 2pole, 230V AC
Rated Current(In): 25, 40, 63A
Rated residual operating current(In): 30, 100, 300, 500mA
Technical parameter:
Rated residual non-operating current(Ino): 0.5 In
Residual current off-time: 0.1s
Minimum value of rated breaking capacity(lm): 630A
Rated conditional short-circuit capacity (lnc): 6KA
6. www.meba.net
Residual Current
Circuit Breaker
133
MB089/MB090 Residual Current Circuit Breaker
Applications:
Specification:
Standard
Rated voltage(Un)
Rated current(In)
Rated residual operating current(In)
Rated residual non-operating current(I no)
Breaking capacity(A)
Residual current off-time
Operating temperature
IEC61008-1
1Pole+N: 230/240V AC, 3Pole+N: 400/415V AC
10, 16, 20, 25, 32, 40A
30, 100, 300, 500mA
0.5ls n
6000A
0.1s
-5 +55
Dimensions:
O. OFF
94
35.6
O. OFF
71.2
61.5
76
45
83
MB089/ MB090 4P RCD provide the function of isolation switchingand earth leakageprotection of electricalcircuits. They open a circuit
automatically in the event of an earth fault between phase and earth and/or netural and earth. A wide range of current ratings and
sensitivities are available. Suitable for domestic, commercial and industrial applications.
MB089 MB090
7. www.meba.net
Residual Current
Circuit Breaker
134
MB7L2-63 Residual Current Circuit Breaker
Applications:
MB7L2-63 RCCB provide the function of isolation switching and earth leakage protection of electrical circuits. They open a circuit
automatically in the event of an earth fault between phase and earth and/or netural and earth. Awide range of current ratings and
sensitivities are available. Suitable for domestic, commercial and industrial applications.
Specification:
Standard
Rated voltage(Un)
Rated current(In)
Rated residual operating current(In)
Rated residual non-operating current(I no)
Breaking capacity(A)
Residual current off-time
Operating temperature
IEC61008-1
1Pole+N: 230/240V AC, 3Pole+N: 400/415V AC
10, 16, 20, 25, 32, 40A, 50A, 63A
30, 100, 300, 500mA
0.5ls n
6000A
0.1s
-5 +55
MB7L4-63 Residual Current Circuit Breaker
Applications:
Specification:
Standard
Rated voltage(Un)
Rated current(In)
Rated residual operating current(In)
Rated residual non-operating current(I no)
Breaking capacity(A)
Residual current off-time
Operating temperature
IEC61008-1
1Pole+N: 230/240V AC, 3Pole+N: 400/415V AC
10, 16, 20, 25, 32, 40A, 50A, 63A
30, 100, 300, 500mA
0.5ls n
6000A
0.1s
-5 +55
MB7L4-63 RCCB provide the function of isolation switching and earth leakage protection of electrical circuits. They open a circuit
automatically in the event of an earth fault between phase and earth and/or netural and earth. A wide range of current ratings and
sensitivities are available. Suitable for domestic, commercial and industrial applications.
MB7L2-63 MB7L4-63
8. MBB8LE-63-1P
www.meba.net
Residual Current
Circuit Breaker
135
Applications:
Specification:
Standard
Rated voltage(Un)
Rated current(In)
Rated residual operating current(In)
Rated residual non-operating current(I no)
Breaking capacity(A)
Residual current off-time
Operating temperature
IEC61008-1
1Pole+N: 230/240V AC, 3Pole+N: 400/415V AC
10, 16, 20, 25, 32, 40A
30, 100, 300, 500mA
0.5ls n
6000A
0.1s
-5 +55
MBACH2 Residual Current Circuit Breaker
MBACH2RCCBprovidethe function ofisolation switching andearth leakage protectionof electrical circuits.Theyopena circuit automatically
in the event of an earth fault between phase and earth and/or neutral and earth. A wide range of current ratings and sensitivities are
available. Suitable for domestic, commercial and industrial applications.
Specification:
Technical parameter:
MBB8LE-63-1P Residual Current Circuit Breaker
Residual current circuit breaker with overload protection(RCBO)
Brand Name: Meba
Model Number: MBB8LE-63
Type: Residual current circuit breaker with overload protection(RCBO)
Poles Number: 1 pole MCB + ELCB
MBB8LE-63 1Pole, combination by mini circuit breaker and leakage. Which protect human from the fault of electric because of over-
current, short circuit, earth fault current. It isself-protecting up to a maximum short-circuit current 63A. All breaking capacities comply
with Standard IEC/EN 61009.
Residual current device with overcurrent protection
Combine in residual current device function and MCB over-current protection function
Short circuit capacity: 6KA
Rated current(A): 6, 16, 20, 25, 32, 40, 50, 63A
Rated leakage operating current(mA): 30, 100, 300mA
AC types, B-C characteristic
Modular Din Rail products 35mm.
MBACH2
9. www.meba.net
Residual Current
Circuit Breaker
136
MBEA-63A Residual Current Circuit Breaker
Applications:
Specification:
Standard
Rated voltage(Un)
Rated current(In)
Rated residual operating current(In)
Rated residual non-operating current(I no)
Breaking capacity(A)
Residual current off-time
Operating temperature
IEC61008-1
1Pole+N: 230/240V AC, 3Pole+N: 400/415V AC
10, 16, 20, 25, 32, 40A, 50A, 63A
30, 100, 300, 500mA
0.5ls n
6000A
0.1s
-5 +55
MBEA-63A RCCB provide the function of isolation switching and earth leakage protection of electrical circuits. They open a circuit
automatically in the event of an earth fault be tween phase and earth and/or neutral and earth. A wide range of current ratings and
sensitivities are available. Suitable for domestic, commercial and industrial applications.
MBB8LE-63-2P Residual Current Circuit Breaker
Residual current circuit breaker with overload protection(RCBO)
Brand Name: Meba
Model Number: MBB8LE-63
Type: Residual current circuit breaker with overload protection(RCBO)
Poles Number: 2 pole MCB + ELCB
Specification:
MBB8LE-63 2Pole, combination by mini circuit breaker and leakage. Which protect humanfrom the fault of electric because of over-
current, short circuit, earth fault current. It is self-protecting up to a maximum short-circuit current 63A. All breakingcapacities comply
with Standard IEC/EN 61009.
Technical parameter:
Residual current device with overcurrent protection
Combine in residual current device function and MCB over-current protection function
Short circuit capacity: 6KA
Rated current(A): 6, 16, 20, 25, 32, 40, 50, 63A
Rated leakage operating current(mA): 30, 100, 300mA
AC types, B-C characteristic
Modular Din Rail products 35mm.
MBB8LE-63-2P MBEA-63A
10. www.meba.net
Residual Current
Circuit Breaker
Applications:
MBEFI-2/MBEFI-4 Residual Current Circuit Breaker
Residual current circuitbreakers MBEFI areused for protectionagainst indirect touching of parts under voltage, for prevention of lasting
voltage on earthed par ts which should appear because of a defectin the electricalinstallation and for protection against direct conta cts
of parts under voltage in case of I n 30mA. Residual current circuit breakers can beused in TN-S, TN-C, TT and ITnetwork systems
or with other words in all systems where neutral and protective conductor are separated (VDE 0100 Teil 410).
Types - Our programme comprises residual current circuit breakers which are sensitive to alternating residu al current (AC-type) and
residual current circuit breakers which are sensitive to alternating and pulsating direct current (A-type).
For alternating residual current
For alternating and pulsating direct residual current
Short-circuit capacity with back-up fuse
lower temperature limit of application -25 C
VDE 0664, part 1 (up to 80 A)
Selective (time delayed min. 40 ms)
Short time delayed (min. 10 ms)
type A type AC type G type A type AC type S type G
MBEFI2 MBEFI4
MBEFI-2 Specification:
16
25
40
63
80
100
16
25
40
63
80
100
16
25
40
63
80
100
16
25
40
63
80
0,03
0,03
0,03
0,03
0,03
0,03
0,1
0,1
0,1
0,1
0,1
0,1
0,3
0,3
0,3
0,3
0,3
0,3
0.5
0,5
0,5
0,5
0,5
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
002062521
002062522
002062523
002062524
002062525
002063521
002063522
002063523
002063524
002063525
002063526
002064521
002064522
002064523
002064524
002064525
002064526
002065521
002065522
002065523
002065524
002065525
002062121
002062122
002062123
002062124
002062125
002062126
002063121
002063122
002063123
002063124
002063125
002064121
002064122
002064123
002064124
002064125
002064126
002065121
002065122
002065123
002065124
002065125
229
229
229
244
244
244
223
223
223
227
230
230
223
223
223
227
230
230
223
223
223
227
230
1/54
1/54
1/54
1/54
1/54
1/54
1/54
1/54
1/54
1/54
1/54
1/54
1/54
1/54
1/54
1/54
1/54
1/54
1/54
1/54
1/54
1/54
1/54
MBEFI-2 type A, MBEFI-2 type AC
In
[A]
I n
[A]
number
of poles code No.A code No.AC
weight
[g]
packaging
[pcs]
MBEFI-2 MBEFI-4
137
11. www.meba.net
Residual Current
Circuit Breaker
MBEFI-2/MBEFI-4 Residual Current Circuit Breaker
MBEFI-2 type G
25
25
40
40
0,03
0,1
0,3
0,1
2
2
2
2
002062722*
002063722*
002062723*
002063723*
220
220
220
220
1/54
1/54
1/54
1/54
In
[A]
I n
[A]
number
of poles code No.AC
weight
[g]
packaging
[pcs]
*The same housing as MBEFI-2 100 A.
* type with N-pole on the left side is also available.
16
25
40
63
80
100
16
25
40
63
80
100
16
25
40
63
80
100
16
25
40
63
80
0,03
0,03
0,03
0,03
0,03
0,03
0,1
0,1
0,1
0,1
0,1
0,1
0,3
0,3
0,3
0,3
0,3
0,3
0.5
0,5
0,5
0,5
0,5
MBEFI-4 type A, MBEFI-4 type AC
In
[A]
I n
[A]
number
of poles code No.A code No.AC
weight
[g]
packaging
[pcs]
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
002062541
002062542
002062543
002062544
002062545
002062546
002063541
002063542
002063543
002063544
002063545
002063546
002064541
002064542
002064543
002064544
002064545
002064546
002065541
002065542
002065543
002065544
002065545
002062141
002062142
002062143
002062144
002062145
002062146
002063141
002063142
002063143
002063144
002063145
002063146
002064141
002064142
002064143
002064144
002064145
002064146
002065141
002065142
002065143
002065144
002065145
393
393
393
400
407
407
393
393
393
400
407
407
364
364
364
372
372
372
364
364
364
372
372
1/27
1/27
1/27
1/27
1/27
1/27
1/27
1/27
1/27
1/27
1/27
1/27
1/27
1/27
1/27
1/27
1/27
1/27
1/27
1/27
1/27
1/27
1/27
MBEFI-4 type G
40
40
0,03
0,1
4
4
320
320
1/27
1/27
In
[A]
I n
[A]
number
of poles code No.AC
weight
[g]
packaging
[pcs]
*The same housingas MBEFI-4 100 A.
002062743*
002063743*
MBEFI-4 type S
40
63
0,3
0,3
4
4
400
400
1/27
1/27
In
[A]
I n
[A]
number
of poles code No.AC
weight
[g]
packaging
[pcs]
002064243
002064244
MBEFI-4 Specification:
MBETI also manufactures tripping relaysused in residual current circuit breakers-the range of products and their technical data is available in
technical information published separately.
MBEFI-2 MBEFI-4
138
12. www.meba.net
Residual Current
Circuit Breaker
PFIM-2P
Electromagnetic and Electronic type
35mm wide for 2 pole Din Rail installation.
Standsrd: IEC1008/EN61008
Rated Voltage(Un): 2pole, 230V AC
Rated Current(In): 25, 40, 63A
Rated residual operating current(I n): 30, 100, 300, 500mA
Rated residual non-operating current(I no): 0.5 I n
Residual current off-time: 0.1s
Minimum value of rated breaking capacity(lm): 630A
Rated conditional short-circuit capacity (lnc): 6KA
Specification:
PFIM-2P Residual Current Circuit Breaker
Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: PFIM
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P
PFIM 2P, Residual CurrentDevices for earthleakage detection. It isto be used in associationwith miniature circuitbreakers, its function
is to detect earth leakage current and openthe connected circuit to protect people andequipment, major usedin industrial appli cation.
These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.
Technical parameter:
MBR2 Residual Current Circuit Breaker
Applications:
Specification:
Standard
Rated voltage(Un)
Rated current(In)
Rated residual operating current(In)
Rated residual non-operating current(I no)
Breaking capacity(A)
Residual current off-time
Operating temperature
IEC61008-1
1Pole+N: 230/240V AC, 3Pole+N: 400/415V AC
10, 16, 20, 25, 32, 40A
30, 100, 300, 500mA
0.5ls n
6000A
0.1s
-5 +55
MBR2 RCCB provide the function of isolat ion switching and earth leakage protection of electrical circuits . They open a circuit automatically
in the event of an earth fault between phase and earth and/or neutral and earth. A wide range of current ratings and sen sitivities are
available. Suitable for domestic, commercial and industrial applications.
MBR2
139
13. www.meba.net
Residual Current
Circuit Breaker
PFIM-40-2P Residual Current Circuit Breaker
Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: PFIM
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P
Specification:
PFIM 2P, Residual CurrentDevicesfor earth leakage detection.It is to be used in association with miniature circuit breakers, its function
is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.
These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.
Technical parameter:
Electromagnetic and Electronic type
35mm wide for 2 pole Din Rail installation.
Standsrd: IEC1008/EN61008
Rated Voltage(Un): 2pole, 230V AC
Rated Current(In): 25, 40, 63A
Rated residual operating current(I n): 30, 100, 300, 500mA
Rated residual non-operating current(I no): 0.5 I n
Residual current off-time: 0.1s
Minimum value of rated breaking capacity(lm): 630A
Rated conditional short-circuit capacity (lnc): 6KA
PFIM-40-4P Residual Current Circuit Breaker
Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: PFIM
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 4P
Specification:
PFIM 4P, Residual CurrentDevices for earthleakage detection. Itis to beused in associationwith miniature circuitbreakers, its function
is to detect earth leakage current and open theconnected circuit toprotect people andequipment, major used in industrial applicati on.
These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.
PFIM-40-2P PFIM-40-4P
Technical parameter:
Electromagnetic and Electronic type
70mm wide for 4 pole Din Rail installation.
Standsrd: IEC1008/EN61008
Rated Voltage(Un): 4pole, 400V AC
Rated Current(In): 25, 40, 63A
Rated residual operating current(I n): 30, 100, 300, 500mA
Rated residual non-operating current(I no): 0.5 I n
Residual current off-time: 0.1s
Minimum value of rated breaking capacity(lm): 630A
Rated conditional short-circuit capacity (lnc): 6KA
140
14. www.meba.net
Residual Current
Circuit Breaker
Specification:
Technical parameter:
Specification:
Technical parameter:
RCCB-OLL4-2P Residual Current Circuit Breaker
Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: OLL4
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P
OLL4, Residual Current Devices for earth leakage detection. It is to be used in association with miniature circuit breakers, its function
is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.
These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.
Electromagnetic and Electronic type
35mm wide for 2 pole Din Rail installation.
Standsrd: IEC1008/EN61008
Rated Voltage(Un): 2pole, 230V AC
Rated Current(In): 25, 40, 63A
Rated residual operating current(I n): 30, 100, 300, 500mA
Rated residual non-operating current(I no): 0.5 I n
Residual current off-time: 0.1s
Minimum value of rated breaking capacity(lm): 630A
Rated conditional short-circuit capacity (lnc): 6KA
RCCB-OLL4-4P Residual Current Circuit Breaker
Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: OLL4
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 4P
OLL4, Residual Current Devices for earth leakage detection. It is to be used in association with miniature circuit breakers, its function
is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.
These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.
Electromagnetic and Electronic type
70mm wide for 4 pole Din Rail installation.
Standsrd: IEC1008/EN61008
Rated Voltage(Un): 4pole, 400V AC
Rated Current(In): 25, 40, 63A
Rated residual operating current(I n): 30, 100, 300, 500mA
Rated residual non-operating current(I no): 0.5 I n
Residual current off-time: 0.1s
Minimum value of rated breaking capacity(lm): 630A
Rated conditional short-circuit capacity (lnc): 6KA
RCCB-OLL4-2P RCCB-OLL4-4P
141
15. Technical parameter:
www.meba.net
Specification:
Technical parameter:
Specification:
Residual Current
Circuit Breaker
RCD-FIN-2P Residual Current Circuit Breaker
Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: FIN
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P
FIN 2P, Residual Current Devices for earth leakage detection. It is to be used in association with miniature circuit breakers, its function
is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.
These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.
Electromagnetic and Electronic type
35mm wide for 2 pole Din Rail installation.
Standsrd: IEC1008/EN61008
Rated Voltage(Un): 2pole, 230V AC
Rated Current(In): 25, 40, 63A
Rated residual operating current(I n): 30, 100, 300, 500mA
Rated residual non-operating current(I no): 0.5 I n
Residual current off-time: 0.1s
Minimum value of rated breaking capacity(lm): 630A
Rated conditional short-circuit capacity (lnc): 6KA
RCD-FIN-4P Residual Current Circuit Breaker
Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: FIN
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 4P
FIN, Residual Current Devices for earth leakage detection. It is to be used in association with miniature circuit breakers, its function is
to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industr ial applicati on.
These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.
Electromagnetic and Electronic type
70mm wide for 4 pole Din Rail installation.
Standsrd: IEC1008/EN61008
Rated Voltage(Un): 4pole, 400V AC
Rated Current(In): 25, 40, 63A
Rated residual operating current(I n): 30, 100, 300, 500mA
Rated residual non-operating current(I no): 0.5 I n
Residual current off-time: 0.1s
Minimum value of rated breaking capacity(lm): 630A
Rated conditional short-circuit capacity (lnc): 6KA
RCD-FIN-2P RCD-FIN-4P
142
16. www.meba.net
Residual Current
Circuit Breaker
Specification:
Technical parameter:
Specification:
Technical parameter:
RCD-ID-2P Residual Current Circuit Breaker
Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: ID
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P
ID 2P, Residual Current Devices for earth leakage detection. It is to be used in association with miniature circuit breakers, its function
is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.
These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.
Electromagnetic and Electronic type
35mm wide for 2 pole Din Rail installation.
Standsrd: IEC1008/EN61008
Rated Voltage(Un): 2pole, 230V AC
Rated Current(In): 25, 40, 63A
Rated residual operating current(I n): 30, 100, 300, 500mA
Rated residual non-operating current(I no): 0.5 I n
Residual current off-time: 0.1s
Minimum value of rated breaking capacity(lm): 630A
Rated conditional short-circuit capacity (lnc): 6KA
RCD-ID-4P Residual Current Circuit Breaker
Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: ID
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 4P
ID, Residual Current Devices for earth leakage det ection. It is to be used in association with miniature circuit breakers, its function is
to detect earth leakag e current and open the connected circuit to protect people and equipment, major used in industrial application.
These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.
Electromagnetic and Electronic type
70mm wide for 4 pole Din Rail installation.
Standsrd: IEC1008/EN61008
Rated Voltage(Un): 4pole, 400V AC
Rated Current(In): 25, 40, 63A
Rated residual operating current(I n): 30, 100, 300, 500mA
Rated residual non-operating current(I no): 0.5 I n
Residual current off-time: 0.1s
Minimum value of rated breaking capacity(lm): 630A
Rated conditional short-circuit capacity (lnc): 6KA
RCD-ID-2P RCD-ID-4P
143
17. Technical parameter:
www.meba.net
Specification:
Technical parameter:
Specification:
Residual Current
Circuit Breaker
RCD-MNL-2P Residual Current Circuit Breaker
Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: MNL
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P
MNL, Residual Current Devices for earth leakage detection. It is to be used in association with miniature circuit breakers, its function
is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.
These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.
Electromagnetic and Electronic type
35mm wide for 2 pole Din Rail installation.
Standsrd: IEC1008/EN61008
Rated Voltage(Un): 2pole, 230V AC
Rated Current(In): 25, 40, 63A
Rated residual operating current(I n): 30, 100, 300, 500mA
Rated residual non-operating current(I no): 0.5 I n
Residual current off-time: 0.1s
Minimum value of rated breaking capacity(lm): 630A
Rated conditional short-circuit capacity (lnc): 6KA
RCD-MNL-4P Residual Current Circuit Breaker
Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: MNL
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 4P
MNL, Residual Current Devices for earth leakage detection. It is to be used in association with miniature circuit breakers, its function
is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.
These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.
Electromagnetic and Electronic type
70mm wide for 4 pole Din Rail installation.
Standsrd: IEC1008/EN61008
Rated Voltage(Un): 4pole, 400V AC
Rated Current(In): 25, 40, 63A
Rated residual operating current(I n): 30, 100, 300, 500mA
Rated residual non-operating current(I no): 0.5 I n
Residual current off-time: 0.1s
Minimum value of rated breaking capacity(lm): 630A
Rated conditional short-circuit capacity (lnc): 6KA
RCD-MNL-2P RCD-MNL-4P
144
18. www.meba.net
Residual Current
Circuit Breaker
Specification:
Technical parameter:
Specification:
Technical parameter:
RCD-NFIN Residual Current Circuit Breaker
Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: NFIN
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P
NFIN, Residual Current Devices for earth leakage detection. It is to be used in association with miniature circuit breakers, its function
is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.
These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.
Electromagnetic and Electronic type
35mm wide for 2 pole Din Rail installation.
Standsrd: IEC1008/EN61008
Rated Voltage(Un): 2pole, 230V AC
Rated Current(In): 25, 40, 63A
Rated residual operating current(I n): 30, 100, 300, 500mA
Rated residual non-operating current(I no): 0.5 I n
Residual current off-time: 0.1s
Minimum value of rated breaking capacity(lm): 630A
Rated conditional short-circuit capacity (lnc): 6KA
RCD-OLL1-2P Residual Current Circuit Breaker
Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: OLL1
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P
OLL1, Residual Current Devices for earth leakage detection. It is to be used in association with miniature circuit breakers, its function
is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.
These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.
Electromagnetic and Electronic type
35mm wide for 2 pole Din Rail installation.
Standsrd: IEC1008/EN61008
Rated Voltage(Un): 2pole, 230V AC
Rated Current(In): 25, 40, 63A
Rated residual operating current(I n): 30, 100, 300, 500mA
Rated residual non-operating current(I no): 0.5 I n
Residual current off-time: 0.1s
Minimum value of rated breaking capacity(lm): 630A
Rated conditional short-circuit capacity (lnc): 6KA
RCD-NFIN RCD-OLL1-2P
145
19. Specification:
OLL18-63, replace of DZ18-20, Residual Current Devic es for
earth leakage detection. Itis tobe usedin associationwith miniature
circuit breakers, its function is todetect earth leakagecurrent and
open the connectedcircuit to protect people and equipment, major
used in industrial application. These devices are designed to meet
the Earth LeakageProtection Standards of the IEC: IEC/EN 61008.
Technical parameter:
www.meba.net
Specification:
Technical parameter:
Residual Current
Circuit Breaker
RCD-OLL1-4P Residual Current Circuit Breaker
Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: OLL1
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 4P
OLL1-4P, Residual CurrentDevices for earthleakage detection. It is to be usedin association with miniaturecircuit breakers, itsfunction
is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.
These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.
Electromagnetic and Electronic type
70mm wide for 4 pole Din Rail installation.
Standsrd: IEC1008/EN61008
Rated Voltage(Un): 4pole, 400V AC
Rated Current(In): 25, 40, 63A
Rated residual operating current(I n): 30, 100, 300, 500mA
Rated residual non-operating current(I no): 0.5 I n
Residual current off-time: 0.1s
Minimum value of rated breaking capacity(lm): 630A
Rated conditional short-circuit capacity (lnc): 6KA
RCD-OLL18-63 Residual Current Circuit Breaker
Brand Name: Meba
Model Number: OLL18-63
Type: Residual Current CircuitBreaker or ResidualCurrent Device
Release Type:Electromagnetic
Electromagnetic
Standsrd: IEC1008/EN61008
Rated Voltage(Un): 230V AC
Rated Current(In): 25, 40, 63A
Rated residual operating current(I n): 30, 100, 300, 500mA
Rated residual non-operating current(I no): 0.5 I n
Residual current off-time: 0.1s
Minimum value of rated breaking capacity(lm): 630A
Rated conditional short-circuit capacity (lnc): 6KA
Dimensions(mm):
Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
N 2
N 1
26.3 0.3
62 0.8
740.8
82.50.8
61 0.8
RCD-OLL1-4P RCD-OLL18-63
146
20. www.meba.net
Residual Current
Circuit Breaker
Specification:
Technical parameter:
Specification:
Technical parameter:
RCD-OLL2-2P Residual Current Circuit Breaker
Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: OLL2
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P
OLL2, Residual Current Devices for earth leakage detection. It is to be used in association with miniature circuit breakers, its function
is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.
These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.
Electromagnetic and Electronic type
35mm wide for 2 pole Din Rail installation.
Standsrd: IEC1008/EN61008
Rated Voltage(Un): 2pole, 230V AC
Rated Current(In): 25, 40, 63A
Rated residual operating current(I n): 30, 100, 300, 500mA
Rated residual non-operating current(I no): 0.5 I n
Residual current off-time: 0.1s
Minimum value of rated breaking capacity(lm): 630A
Rated conditional short-circuit capacity (lnc): 6KA
RCD-OLL2-4P Residual Current Circuit Breaker
Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: OLL2
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 4P
OLL2, Residual Current Devices for earth leakage detection. It is to be used in association with miniature circuit breakers, its function
is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.
These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.
Electromagnetic and Electronic type
70mm wide for 4 pole Din Rail installation.
Standsrd: IEC1008/EN61008
Rated Voltage(Un): 4pole, 400V AC
Rated Current(In): 25, 40, 63A
Rated residual operating current(I n): 30, 100, 300, 500mA
Rated residual non-operating current(I no): 0.5 I n
Residual current off-time: 0.1s
Minimum value of rated breaking capacity(lm): 630A
Rated conditional short-circuit capacity (lnc): 6KA
RCD-OLL2-2P RCD-OLL2-4P
147
21. www.meba.net
Specification:
Technical parameter:
Residual Current
Circuit Breaker
RCD-OLL2-N-2P Residual Current Circuit Breaker
Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: OLL2-N
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P
OLL2-N, Residual Current Devices for earth leakage detection. It is tobe used inassociation with miniaturecircuit breakers, itsfunction
is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.
These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.
Electromagnetic and Electronic type
35mm wide for 2 pole Din Rail installation.
Standsrd: IEC1008/EN61008
Rated Voltage(Un): 2pole, 230V AC
Rated Current(In): 25, 40, 63A
Rated residual operating current(I n): 30, 100, 300, 500mA
Rated residual non-operating current(I no): 0.5 I n
Residual current off-time: 0.1s
Minimum value of rated breaking capacity(lm): 630A
Rated conditional short-circuit capacity (lnc): 6KA
RCD-OLL2-N-4P Residual Current Circuit Breaker
Specification:
Technical parameter:
Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: OLL2-N
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 4P
OLL2-N, Residual Current Devic es for earth leakage detection. It is tobe used inassociation with miniaturecircuit breakers, itsfunction
is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.
These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.
Electromagnetic and Electronic type
70mm wide for 4 pole Din Rail installation.
Standsrd: IEC1008/EN61008
Rated Voltage(Un): 4pole, 400V AC
Rated Current(In): 25, 40, 63A
Rated residual operating current(I n): 30, 100, 300, 500mA
Rated residual non-operating current(I no): 0.5 I n
Residual current off-time: 0.1s
Minimum value of rated breaking capacity(lm): 630A
Rated conditional short-circuit capacity (lnc): 6KA
RCD-OLL2-N-2P RCD-OLL2-N-4P
148
22. www.meba.net
Residual Current
Circuit Breaker
Specification:
Technical parameter:
Specification:
Technical parameter:
RCD-OLL7-2P Residual Current Circuit Breaker
Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: OLL7
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P
OLL7, Residual Current Devices for earth leakage detection. It is to be used in association with miniature circuit breakers, its function
is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.
These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.
Electromagnetic and Electronic type
35mm wide for 2 pole Din Rail installation.
Standsrd: IEC1008/EN61008
Rated Voltage(Un): 2pole, 230V AC
Rated Current(In): 25, 40, 63A
Rated residual operating current(I n): 30, 100, 300, 500mA
Rated residual non-operating current(I no): 0.5 I n
Residual current off-time: 0.1s
Minimum value of rated breaking capacity(lm): 630A
Rated conditional short-circuit capacity (lnc): 10KA
RCD-OLL7-4P Residual Current Circuit Breaker
Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: OLL7
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 4P
OLL7, Residual Current Devices for earth leakage detection. It is to be used in association with miniature circuit breakers, its function
is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.
These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.
Electromagnetic and Electronic type
70mm wide for 4 pole devices Din Rail installation.
Standsrd: IEC1008/EN61008
Rated Voltage(Un): 4pole, 400V AC
Rated Current(In): 25, 40, 63A
Rated residual operating current(I n): 30, 100, 300, 500mA
Rated residual non-operating current(I no): 0.5 I n
Residual current off-time: 0.1s
Minimum value of rated breaking capacity(lm): 630A
Rated conditional short-circuit capacity (lnc): 10KA
RCD-OLL7-2P RCD-OLL7-4P
149
23. www.meba.net
Specification:
Technical parameter:
Residual Current
Circuit Breaker
Specification:
Technical parameter:
RCD-OLL7-3-2P Residual Current Circuit Breaker
Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: OLL7-3
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P
OLL7-3, Resid ual Current Devices forearth leakage detection. It is tobe used inassociati on with miniature circuit breakers, its function
is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.
These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.
Electromagnetic and Electronic type
35mm wide for 2 pole Din Rail installation.
Standsrd: IEC1008/EN61008
Rated Voltage(Un): 2pole, 230V AC
Rated Current(In): 25, 40, 63A
Rated residual operating current(I n): 30, 100, 300, 500mA
Rated residual non-operating current(I no): 0.5 I n
Residual current off-time: 0.1s
Minimum value of rated breaking capacity(lm): 630A
Rated conditional short-circuit capacity (lnc): 10KA
RCD-OLL7-3-4P Residual Current Circuit Breaker
Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: OLL7-3
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 4P
OLL7-3, Residual Current Devices for earth leakag e detection. It is to beused in associationwith miniature circuit breakers, its function
is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.
These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.
Electromagnetic and Electronic type
70mm wide for 4 pole Din Rail installation.
Standsrd: IEC1008/EN61008
Rated Voltage(Un): 4pole, 400V AC
Rated Current(In): 25, 40, 63A
Rated residual operating current(I n): 30, 100, 300, 500mA
Rated residual non-operating current(I no): 0.5 I n
Residual current off-time: 0.1s
Minimum value of rated breaking capacity(lm): 630A
Rated conditional short-circuit capacity (lnc): 10KA
RCD-OLL7-3-2P RCD-OLL7-3-4P
150
24. www.meba.net
Residual Current
Circuit Breaker
Specification:
Technical parameter:
Specification:
Technical parameter:
RCD-OLL7-4-2P Residual Current Circuit Breaker
Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: OLL7-4
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P
OLL7-4, Residual Current Devices forearth leakage detection.It is tobe used in associat ion with miniature circuit breakers, its fun ction
is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.
These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.
Electromagnetic and Electronic type
35mm wide for 2 pole Din Rail installation.
Standsrd: IEC1008/EN61008
Rated Voltage(Un): 2pole, 230V AC
Rated Current(In): 25, 40, 63A
Rated residual operating current(I n): 30, 100, 300, 500mA
Rated residual non-operating current(I no): 0.5 I n
Residual current off-time: 0.1s
Minimum value of rated breaking capacity(lm): 630A
Rated conditional short-circuit capacity (lnc): 10KA
RCD-OLL7-4-4P Residual Current Circuit Breaker
Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: OLL7-4
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 4P
OLL7-4, Residual CurrentDevices for earthleakage detection. It isto be usedin association withminiatur e circuit breaker s, its function
is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.
These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.
Electromagnetic and Electronic type
70mm wide for 4 pole devices Din Rail installation.
Standsrd: IEC1008/EN61008
Rated Voltage(Un): 4pole, 400V AC
Rated Current(In): 25, 40, 63A
Rated residual operating current(I n): 30, 100, 300, 500mA
Rated residual non-operating current(I no): 0.5 I n
Residual current off-time: 0.1s
Minimum value of rated breaking capacity(lm): 630A
Rated conditional short-circuit capacity (lnc): 10KA
RCD-OLL7-4-2P RCD-OLL7-4-4P
151
25. Technical parameter:
Electromagnetic and Electronic type
35mm wide for 2 pole Din Rail installation.
Standsrd: IEC1008/EN61008
Rated Voltage(Un): 2pole, 230V AC
Rated Current(In): 25, 40, 63A
Rated residual operating current(I n): 30, 100, 300, 500mA
Rated residual non-operating current(I no): 0.5 I n
Residual current off-time: 0.1s
Minimum value of rated breaking capacity(lm): 630A
Rated conditional short-circuit capacity (lnc): 10KA
www.meba.net
Residual Current
Circuit Breaker
RCD-PF-2P Residual Current Circuit Breaker
Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Specification:
Brand Name: Meba
Model Number: PF-2P
Type: ResidualCurrent Circuit Breakeror Residual Current Device
Poles Number: 2P
Flexibility:
Model PF, four pole, Residual Current Devices for earth leakage
detection to thestandards of IEC.It is tobe used inassociation with
miniature circuit breakers, its function is to detect earth leakage
current and open the connected circuit to protect people and
equip ment, major used in industrial application.These devicesare
designed to meet the Earth Leakage Protection Standardsof the
IEC: IEC/EN 61008.
With a wide range of currents and rated trip current available, the appropriate level of protection can be chosen for specific applications
for either personnel or equipment protection.
Specification:
Flexibility:
Technical parameter:
RCD-PF-4P Residual Current Circuit Breaker
Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: PF-4P
Type: Residual CurrentCircuit Breaker orResidual Current Device
Poles Number: 4P
Model PF, four pole, Residual Current Devices for earth leakage
detection to thestandards of IEC.It is tobe used inassociation with
miniature circuit breakers, its function isto detect earth leakage
current and open the connected circuit to protect people and
equipment , major used in industrial application.These devicesare
designed to meet the Earth Leakage Protection Standards of the
IEC: IEC/EN 61008.
With a wide range of currents andrated trip current available, the
appropriate level ofprotection can bechosen for specificapplications
for either personnel or equipment protection.
Electromagnetic and Electronic type
70mm wide for 4 pole devices Din Rail installation.
Standsrd: IEC1008/EN61008
Rated Voltage(Un): 4pole, 400V AC
Rated Current(In): 25, 40, 63A
Rated residual operating current(I n): 30, 100, 300, 500mA
Rated residual non-operating current(I no): 0.5 I n
Residual current off-time: 0.1s
Minimum value of rated breaking capacity(lm): 630A
Rated conditional short-circuit capacity (lnc): 10KA
1 N
2 N
H
1 3 5 N
2 4 6 N
H
Operation Principle Fig:
Dimensions(mm):
77 0.8
35.60.3
44.5
66
5.5
45
83.2
66.30.3
35.3 0.3
7236
RCD-PF-2P RCD-PF-4P
152