SlideShare a Scribd company logo
1 of 71
1
The Pushover Analysis
– from basics
Presented by .
Rahul Leslie
Assistant Director,
Buildings Design,
DRIQ, Kerala PWD,
Trivandrum, India
2
Introduction
• Performance Based Design --- an emerging field
– To provide engineers with a capability to design buildings that have
predictable and reliable performance in earthquakes
– It employs concept of ‘performance objectives’, which is the
specification of an acceptable level of damage on experiencing a
earthquake of a given severity.
(FEMA 349)
• Seismic design for the future
– Presently a linear elastic analysis alone is sufficient for both its elastic
and ductile design
– In course of time, for large critical structures, a specially dedicated non-
linear procedure will have to be done, which finally influences the
seismic design as a whole.
The Pushover Analysis – from basics Presented by Rahul Leslie
3
Introduction
• Linear approach (IS:1893-2002)
is based on the Response
Reduction factor R.
– For example, R = 5, means that
1/5th of the seismic force is
taken by the Limit State capacity
of the structure.
– Further deflection is taken by the
ductile capacity of the structure.
– Reinforced Concrete (RC)
members are detailed (as per
IS:13920) to confirm its ductile
capacity.
– We never analyse for the ductile
part, but only follow the
reinforcement detailing
guidelines for the same.
The Pushover Analysis – from basics Presented by Rahul Leslie
4
Introduction
• The drawback is that the response
beyond the limit state is neither a
simple extrapolation, …
• … nor a perfectly ductile behaviour
with pre-determinable deformation
capacity, due to various reasons:
– Change in stiffness of members due
to cracking and yielding,
– P-delta effects,
– Change in the final seismic force
estimated (due to Change in
• time period ‘T’ and
• effective damping ratio ‘ζ’ (also
represented by ‘β’)
– etc.
The Pushover Analysis – from basics Presented by Rahul Leslie
5
Introduction
• Although elastic analysis gives a good indication of elastic capacity
of structures and shows where yielding will first occur,
– It cannot predict the redistribution of forces during the progressive
yielding that follows and predict its failure mechanisms.
• A non-linear static analysis can predict these more accurately.
– It can help identify members likely to reach critical states during an
earthquake for which attention should be given during design and
detailing.
The Pushover Analysis – from basics Presented by Rahul Leslie
6
Introduction
The Pushover Analysis (PA):
• PA is a non-linear analysis procedure to estimate the strength
capacity of a structure beyond its Limit State up to its ultimate
strength.
• It can help demonstrate how progressive failure in buildings most
probably occurs, and identify the mode of final failure.
• The method also predicts potential weak areas in the structure, by
keeping track of the sequence of damages of each and every
member in the structure.
The Pushover Analysis – from basics Presented by Rahul Leslie
7
PA can be useful under two situations:
 When an existing structure has deficiencies in seismic resisting
capacity,
 due to either omission of seismic design when built, or
 the structure becoming seismically inadequate due to a later
upgradation of the seismic codes,
is to be retrofitted to meet the (present) seismic demands,
PA can show where the retrofitting is required and how much.
 For a building in its design phase, PA results help scrutinise and
fine tune the seismic design based on SA.
Introduction
The Pushover Analysis – from basics Presented by Rahul Leslie
8
• For a new building, PA is meant to be a second stage analysis (The
first stage being a conventional Seismic analysis - SA).
• This is because the details of reinforcement provided are required to
calculate exact hinge properties (to be covered later)
• But one has to design the structure based on SA in order to obtain
the reinforcement details.
• This means that PA is meant to be a second stage analysis (The first
stage being a conventional SA).
• Thus the emerging methodology to an accurate seismic design is:
1. First a conventional linear seismic analysis based on which a primary
structural design is done;
2. Insertion of hinges determined based on the design/detail and then
3. A pushover analysis is done, followed by
4. Modification of the design and detailing, wherever necessary, based
on the latter analysis.
5. The above steps may have to be iterated, if required.
Introduction
The Pushover Analysis – from basics Presented by Rahul Leslie
9
Features of a Typical Pushover Approach
• The model, which is a Multi-degree of freedom (MDoF) model, is
used for the analysis
There are certain features common to all PA approaches:
1. An analysis model of the building, is generated using a common
analysis-design software package (having facility for PA), like
– STAAD.Pro,
– SAP2000, ETABS,
– MIDAS/Gen, etc.
The Pushover Analysis – from basics Presented by Rahul Leslie
10
Non-linear Building model & Non-linear Hinges
Pushover analysis uses a non-linear computer model
for the analysis:
– This is done by incorporated in the form of non-linear hinges
inserted into an otherwise linear elastic model which one
generates using a common analysis-design software package
(STAAD.Pro, SAP2000, ETABS, MIDAS/Gen, etc.)
– Hinges are points on a structure where one expects cracking
and yielding to occur in relatively higher intensity so that they
show higher flexural/shear displacement, under a cyclic loading
The Pushover Analysis – from basics Presented by Rahul Leslie
11
- These are locations where one expects to see cross
diagonal cracks in an actual building structure after a
seismic mayhem
– they would be at either ends of beams and columns, the ‘cross’
being at a small distance from the joint
– this is where one inserts hinges in the corresponding computer
model.
Non-linear Building model & Non-linear Hinges
The Pushover Analysis – from basics Presented by Rahul Leslie
12
• Basically a hinge represents localised force-displacement relation of
a member through its elastic and inelastic phases under seismic
loads.
• A flexural hinge represents the moment-rotation relation of a beam.
• Hinges are of various types – namely,
– (1) flexural hinges,
– (2) shear hinges
– (3) axial hinges.
Non-linear Building model & Non-linear Hinges
The Pushover Analysis – from basics Presented by Rahul Leslie
13
• The flexural and shear hinges
are inserted into the ends of
beams and columns.
• Since the presence of masonry
infills have significant influence
on the seismic behaviour of
the structure, modelling them
using equivalent diagonal
struts (of ‘truss’ elements) is
common in PA
• The axial hinges are inserted
at either ends of the diagonal
struts
Non-linear Building model & Non-linear Hinges
The Pushover Analysis – from basics Presented by Rahul Leslie
14
Typical Moment Hinge property:
• AB represents the linear range
from unloaded state (A) to its
effective yield (B),
• Followed by an inelastic but
linear response of reduced
(ductile) stiffness from B to C.
• CD shows a sudden reduction
in load resistance, followed by
a reduced resistance from D to
E, and
• finally a total loss of resistance
from E to F.
Flexural Hinge
Non-linear Building model & Non-linear Hinges
The Pushover Analysis – from basics Presented by Rahul Leslie
15
• These hinges have non-linear
states defined within its ductile
range as
– ‘Immediate Occupancy’ (IO),
– ‘Life Safety’ (LS) and
– ‘Collapse Prevention’ (CP)
• This is usually done by dividing
B-C into four parts and
denoting IO, LS and CP, which
are states of each individual
hinges
Flexural Hinge
Non-linear Building model & Non-linear Hinges
The Pushover Analysis – from basics Presented by Rahul Leslie
16
There are certain features common to all PA approaches:
2. The model is pushed monotonically with an invariable distribution of lateral load with some predefined
distribution pattern such as:
– Proportional to 1st
mode (or SRSS combination of modes)
– Inverted triangle / Uniform distribution
– Power distribution (for example, parabolic)
∑
= n
i
k
jj
k
ii
bi
hW
hW
VQ
Features of a Typical Pushover Approach
The Pushover Analysis – from basics Presented by Rahul Leslie
17
There are certain features common to all PA approaches:
2. (Continuation …)
• Unlike conventional SA, in Pushover analysis, analysis for Gravity
loads is done first, continued by an analysis for Lateral loads.
• Since PA is done to simulate the behaviour under actual loads, the
Gravity loads applied are not factored, but in accordance with
Cl.7.3.3 and Table 8 of IS:1893-2002 :
[DL + 0.25 LL≤3kN/sq.m + 0.5 LL>3kN/sq.m]
Features of a Typical Pushover Approach
The Pushover Analysis – from basics Presented by Rahul Leslie
18
3. A pushover curve is obtained, which is a Base shear (Vb) vs. Roof
top displacement (Δrt) curve
– Base shear is sum of all horizontal support reactions in that
direction
– Roof top displacement is the displacement at the centre of
mass of the general roof
Features of a Typical Pushover Approach
The Pushover Analysis – from basics Presented by Rahul Leslie
19
4. A single-degree of freedom (SDoF) model, corresponding to the MDoF model, and
the rules to convert the parameters of the MDoF model (Vb & Δrt) to those of the
SDoF model (Sa & Sd) are defined
Features of a Typical Pushover Approach
The Pushover Analysis – from basics Presented by Rahul Leslie
20
4. (Continuation…) A single-degree of freedom (SDoF) model,
corresponding to the MDoF model, and the rules to convert the
parameters of the MDoF model (Vb & Δrt) to those of the SDoF model
(Sa & Sd) are defined
– In ATC-40 and FEMA440, the conversion is
(where ), and
– In EC 8 (where Sa and Sd are denoted by F* and d* respectively)
and
α
WV
Sa b /
= M
Mk 1=
=α
rtkkP
rt
Sd
@,11 == ⋅
∆
=
φ
1=
=
k
b
P
V
Sa
1=
∆
=
kP
rt
Sd
Features of a Typical Pushover Approach
The Pushover Analysis – from basics Presented by Rahul Leslie
21
5. The Sa-Sd curve has to be converted to an equivalent bi-linear
curve (equal energy) by a suitable method
– Different codes follow different methods
ATC-40 and FEMA440
– ATC-40 and FEMA440 follows the
method of keeping the 1st
line as initial
tangent stiffness and adjusts the 2nd
line (to the point under consideration)
such that to get the ‘equal area’.
Features of a Typical Pushover Approach
The Pushover Analysis – from basics Presented by Rahul Leslie
22
5. The Sa-Sd curve has to be converted to an equivalent bi-linear
curve (equal energy) by a suitable method
– Different codes follow different methods
EC 8
– EC8 (EuroCode 8) follows the method of
keeping the 2nd
line (to the point under
consideration) as ‘perfectly plastic’, ie.,
horizontal and adjusts the 1st line such
that to get the ‘equal area’.
Features of a Typical Pushover Approach
The Pushover Analysis – from basics Presented by Rahul Leslie
23
5. The Sa-Sd curve has to be converted to an equivalent bi-linear
curve (equal energy) by a suitable method
– Different codes follow different methods
ATC-40 and FEMA440 EC8
Features of a Typical Pushover Approach
The Pushover Analysis – from basics Presented by Rahul Leslie
24
PA procedures can generally be classified to two:
1. DCM (Displacement Coeff. Method): These procedures
estimates a Target displacement prior to the analysis, to which
the model has to be pushed, and on analysis, checked for the
intended (good) performance at that displacement. The method
is nevertheless, iterative. Ref:-
- FEMA356,
- FEMA440 (Ch.5),
- EC 8
2. CSM (Capacity Spectrum Method): The analysis is done, and
each pt. on the pushover curve (known as Capacity curve) is
consecutively checked to see whether the Sa-Sd at that pt.
meets (or intersects) the Response Spectrum curve (known as
Demand curve), reduced by a factor. (continued…)
Different Pushover Approaches
The Pushover Analysis – from basics Presented by Rahul Leslie
25
PA procedures can generally be classified to two:
2. CSM : … For each point on the Capacity curve, the Demand
curve to be checked with, for intersection, is a Response
Spectrum curve reduced by a reduction factor calculated
corresponding to that point under consideration on the Capacity
curve. When the curves intersects (or meet), that meeting point
is known as the Performance Pt. Ref:-
- ATC-40,
- FEMA440 (Ch.6)
- EC8 (Optional method)
Different Pushover Approaches
The Pushover Analysis – from basics Presented by Rahul Leslie
26
The steps for the CSM method are:
1. First, the Response Spectrum (RS) curve has to be modified: from its ordinates of Sa vs. Time period ‘T’, to its
‘Acceleration Displacement Response Spectrum’ (ADRS) form, which is an Sa vs. Sd curve.
• This to facilitate the super-imposing the pushover curve over the RS (which is in its ADRS form)
RS ADRS
Steps for CSM method of Pushover Analysis
The Pushover Analysis – from basics Presented by Rahul Leslie
27
The steps for the CSM method are:
1. First, the Response Spectrum (RS) curve has to be modified:
from its ordinates of Sa vs. Time period, to its ‘Acceleration
Displacement Response Spectrum’ (ADRS) form, which is an
Sa vs. Sd curve.
• This is done by using the relation
RS ADRS
Sa
T
Sd 2
2
4π
=
Steps for CSM method of Pushover Analysis
The Pushover Analysis – from basics Presented by Rahul Leslie
28
2. Super-impose the converted Pushover curve on the ADRS curve:
Steps for CSM method of Pushover Analysis
The Pushover Analysis – from basics Presented by Rahul Leslie
29
3. With the Capacity curve (Pushover curve) superimposed on the Demand
curve (ADRS), each point on the former is consecutively checked to :
i. Get the yield point ordinates (Say & Sdy)
ii. Calculate the ductility μ and the 2nd
tangent stiffness coeff. α
ATC-40, FEMA440 EC8
Steps for CSM method of Pushover Analysis
The Pushover Analysis – from basics Presented by Rahul Leslie
30
iii. Determine the reduced ADRS for the above parameters corresponding to that pt. on the Capacity curve
as:
 ATC-40/FEMA440 : Calculate damping β from ductility μ and 2nd
tangent stiffness coefficient α. Reduce ADRS
corresponding to β
 EC 8 : Reduce ADRS corresponding to ductility μ
ATC-40, FEMA440 EC8
Steps for CSM method of Pushover Analysis
The Pushover Analysis – from basics Presented by Rahul Leslie
31
• For example, in ATC-40, for the reduction of the Demand (ADRS)
curve, the ‘effective’ damping ratio β is determined from the
formula :
Steps for CSM method of Pushover Analysis
y
p
d
d
=µ
( )( )
( )ααµπµ
αµ
κβ
−+
−−
+=
1
112
05.0eff
init
nd
K
K2
=α
y
y
init
d
a
K =
yp
yp
nd
dd
aa
K
−
−
=2
The Pushover Analysis – from basics Presented by Rahul Leslie
32
• …where the Damping Modification Factor κ is determined from
the building type
Table : Structural behaviour types Table : Values for Damping
Modification Factor κ
Shaking
Duration
Essentially
New
Building
Average
Existing
Building
Poor
Existing
Building
Short Type A Type B Type C
Long Type B Type C Type C
Structure
behaviou
r type
βeq(%)
κ
Type A
≤16.25 1.0
>16.25
Type B
≤25 0.67
>25
Type C
Any
value
0.33
( ) 02/51.013.1 βπ−
( ) 02/446.0845.0 βπ−
Steps for CSM method of Pushover Analysis
( )( )
( )ααµπµ
αµ
κβ
−+
−−
+=
1
112
05.0eff
The Pushover Analysis – from basics Presented by Rahul Leslie
33
( )
12.2
681.021.3 (%)effeLog
SRa
β−
=
( )
65.1
41.031.2 (%)effeLog
SRv
β−
=
• From the effective damping ratio β, the factors for reducing the
ADRS curve are determined from the formula :
Steps for CSM method of Pushover Analysis
The Pushover Analysis – from basics Presented by Rahul Leslie
34
4. Include the reduced ADRS Demand curve in the super-imposed
graph:
Steps for CSM method of Pushover Analysis
The Pushover Analysis – from basics Presented by Rahul Leslie
35
Step by step through each method
1. The conventional SA procedure is explained to highlight the
difference in approaches between SA & PA
2. Trace the progress of a PA from beginning to end,
• both demonstrates plots of Vb vs Δroof top and RS curve in its
– separate and uncombined form and
– also their transformed and super-positioned ADRS plot.
The Pushover Analysis – from basics Presented by Rahul Leslie
36
• In SA, the maximum DBE force acting on the structure is Z/2.(Sa/g),
(assuming I = 1) with Sa/g corresponding to the estimated time
period.
• Its envelop is the RS curve marked q
• The RS curve for the Limit State design is plotted in terms of Z/2R.
(Sa/g), and is marked as curve p.
Step by step through each method
-- SA Method
The Pushover Analysis – from basics Presented by Rahul Leslie
37
• Fig. shows the Vb vs Δroof top displacement.
– The point P represents the Vb and Δroof top for the design lateral load
(ie., of 1/R times full load)
– The point Q represents the same for the full load, had the building
been fully elastic
– Point Q' for a perfectly-elastic perfectly-ductile structure.
– The slope of the line OP represents
the stiffness of the structure in a
global sense. Since the analysis is
linear, the stiffness remains same
throughout the analysis, with Q
being an extension of OP.
Step by step through each method
-- SA Method
The Pushover Analysis – from basics Presented by Rahul Leslie
38
Step by step through each method
-- SA Method
• The same is represented in Fig.(left) where, for the time period Tp of
the structure,
– the full load is represented by Q (Saq), and
– the design load by P (Sap).
The Pushover Analysis – from basics Presented by Rahul Leslie
39
Step by step through each method
-- SA Method
• The ADRS representation of SA is as in Fig.(left).
– the full load is represented by Q (Saq),
– the design load by P (Sap).
The Pushover Analysis – from basics Presented by Rahul Leslie
40
Step by step through each method
-- PA Method
Now we shall see how differently the PA approaches the same
scenario :-
• The segment OA in Fig.(left) is equivalent to OP in Fig.(right), with the
slope representing the global stiffness in its elastic range.
The Pushover Analysis – from basics Presented by Rahul Leslie
41
Step by step through each method
-- PA Method
The RS curve : Segment OA has time period Ta, curve ‘a’ representing
the RS curve and Saa is the lateral load demand, in its elastic range.
The Pushover Analysis – from basics Presented by Rahul Leslie
42
Step by step through each method
-- PA Method
• ADRS representation:
The Pushover Analysis – from basics Presented by Rahul Leslie
43
Step by step through each method
-- PA Method
• As the analysis progresses, the lateral load is monotonically
increased beyond its elastic limit of A, and the first hinges are formed.
This decreases the overall stiffness of the structure. This is
represented by the segment AB.
• The decrease in slope of OB from that of OA shows the change in
secant stiffness.
The Pushover Analysis – from basics Presented by Rahul Leslie
44
Step by step through each method
-- PA Method
• The first hinges are formed, decreasing the overall stiffness of the
structure, which in turn increases T and β, represented by point B in
the plots.
The Pushover Analysis – from basics Presented by Rahul Leslie
45
Step by step through each method
-- PA Method
• The change in the x-axis value of point B from that of point A shows
the shift of time period from Ta to Tb.
• The increase in β of the structure calls for a corresponding decrease
in the RS curve, reduced by a factor calculated from β, which has thus
come down from curve a to b.
The Pushover Analysis – from basics Presented by Rahul Leslie
46
Step by step through each method
-- PA Method
• ADRS representation: Note the angular shift from Ta to Tb .
• The increase in β of the structure calls for a corresponding decrease
in the RS curve, reduced by a factor calculated from β, which has thus
come down from curve a to b.
The Pushover Analysis – from basics Presented by Rahul Leslie
47
Step by step through each method
-- PA Method
• As the lateral load is further increased monotonically, more hinges are
formed and the existing hinges have further yielded in its non-linear
phase represented by point C
• This has further reduced the stiffness (the slope of OC),
The Pushover Analysis – from basics Presented by Rahul Leslie
48
Step by step through each method
-- PA Method
• (Here are the two graphs overlapped – a possibility
The Pushover Analysis – from basics Presented by Rahul Leslie
49
Step by step through each method
-- PA Method
• This has further reduced the stiffness, and increased T (from Tb to
Tc).
The Pushover Analysis – from basics Presented by Rahul Leslie
50
Step by step through each method
-- PA Method
• More hinges are formed and the existing hinges have further yielded
in its non-linear phase, represented by point C
• Note the angular shift from Tb to Tc.
The Pushover Analysis – from basics Presented by Rahul Leslie
51
Step by step through each method
-- PA Method
• Here the point C is where the capacity curve OABC extending
upwards meets the demand curve in, which was simultaneously
descending down to curve c.
• Thus C is the point where the total lateral force expected Sac is same
as the lateral force applied ~Vbc
• This point is known as the performance point.
The Pushover Analysis – from basics Presented by Rahul Leslie
52
Step by step through each method
-- PA Method
• It is also defined as the point where the ‘locus of the performance
point’, the line connecting Saa, Sab and Sac, intersects the capacity
curve
The Pushover Analysis – from basics Presented by Rahul Leslie
53
PA Method – Reviewing results
• Once the performance point is found, the overall performance of the
structure can be checked to see whether it matches the required
performance level, based on inter-storey drift limits specified in ATC-
40, which are
– 0.01h for IO,
– 0.02h for LS, and
– 0.33(Vb/W)∙h for CP, (h = height of the building).
• The performance level is based on the importance and function of the
building. For example, hospitals and emergency services buildings
are expected to meet a performance level of IO.
The Pushover Analysis – from basics Presented by Rahul Leslie
54
• The next step is to review the hinge formations at performance point.
One can see the individual stage of each hinge, at its location.
• Tables are obtained showing the number of hinges in each state, at
each stage, based on which one decides which all beams and
columns to be redesigned.
• The decision depends whether the most severely yielded hinges are
formed in beams or in columns, whether they are concentrated in a
particular storey denoting soft story, and so on.
PA Method – Reviewing results
OA AB BC
The Pushover Analysis – from basics Presented by Rahul Leslie
55
Adaptation for the Indian Code
Adapting of Pushover Analysis (PA) for IS:1893-2002
• The PA has not been introduced in the Indian Standard code yet.
However the procedure described in ATC-40 can be adapted for the
seismic parameters of IS:1893-2002.
• The RS curve in ATC-40 is
described by parameters
– Ca and
– Cv,
where the curve just as in IS:1893,
is having a flat portion of intensity
2.5 Ca and a downward sloping
portion described by Cv/T.
Resp. Spec (ATC-40)
The Pushover Analysis – from basics Presented by Rahul Leslie
56
• The seismic force in IS:1893-
2000 is represented by
(ZI/2R).(Sa/g), where Sa/g is
obtained from the RS curve,
which in our code is
represented by
– 2.5 in the flat portion &
– the downward sloping
portion by
• 1/T for hard soil,
• 1.36/T for medium
soil and
• 1.67/T for soft soil.
Resp. Spec (IS:1893-2002)






=
g
Sa
R
ZI
Ah
2
Adaptation for the Indian Code
The Pushover Analysis – from basics Presented by Rahul Leslie
57
• On comparison it can be inferred that
– Ca = Z/2 and
– Cv = Z/2 for hard,
1.36∙Z/2 for medium and
1.67∙Z/2 for soft soil
• Here ‘I’ is not considered, since in PA, the criteria of importance of
the structure is taken care of by the performance levels (IO, LS & CP)
• R is also not considered since PA is always done for the full lateral
load.
Resp. Spec (ATC-40) Resp. Spec (IS:1893-2002)






=





=
g
SaZ
g
Sa
R
ZI
Ah
22
Adaptation for the Indian Code
The Pushover Analysis – from basics Presented by Rahul Leslie
58
• The ‘Limit State’ inter-storey drift limit specified in IS:1893-2002, being
0.004, when accounted for
– R = 5 for ductile design and
– I = 1.5 for important structures (IO performance level)
= 1.0 for ordinary structures (LS performance level)
gives 0.004∙R/I = 0.02 and 0.0133 for IO and LS respectively
• The drift limit can be compared with those specified in ATC-40 (0.01
and 0.02 for IO and LS respectively). The limit for IO in IS:1893-2002
is more relaxed than that in ATC-40.
• This 0.004∙R/I can be taken as the IS:1893-2002 limits for pushover
drift, where I takes the values corresponding to Important and
Ordinary structures for limits of IO and LS respectively.
Adaptation for the Indian Code
The Pushover Analysis – from basics Presented by Rahul Leslie
59
• Presented in this section are the results of a pushover analysis done
on a 10 storey RCC building of a shopping complex using the
structural package of SAP2000.
Example of a building analysis
The Pushover Analysis – from basics Presented by Rahul Leslie
60
• In the model, beams and columns were modelled using frame
elements, into which the hinges were inserted.
• Diaphragm action was assigned to the floor slabs to ensure integral
lateral action of beams in each floor.
• Although analysis was done in both transverse and longitudinal
directions, only the results of the former are discussed here.
• The lateral load was applied in pattern of that of the 1st mode shape
in the transverse direction of the building, with an intensity for DBE as
per IS:1893-2002, corresponding to zone-III in hard soil.
Example of a building analysis
The Pushover Analysis – from basics Presented by Rahul Leslie
61
• The ADRS plot shows the Sa and Sd at performance point as 0.085g
and 0.242m.
• The corresponding Vb and Δroof top are 1857.046 kN and 0.287m.
The value of effective T is 3.368s.
• The effective β at that level of the demand curve which met the
performance point is 26%.
Example of a building analysis
The Pushover Analysis – from basics Presented by Rahul Leslie
62
Example of a building analysis
• Table shows the hinge state details at each step of the analysis.
Step
Δroof top
(m)
Vb
(kN)
Hinge States
Total
Hinges
A to
B
B to
IO
IO to
LS
LS to
CP
CP
to C
C to
D
D to
E > E
0 0 0 1752 0 0 0 0 0 0 0 1752
1 0.058318 1084.354 1748 4 0 0 0 0 0 0 1752
2 0.074442 1348.412 1670 82 0 0 0 0 0 0 1752
3 0.089645 1451.4 1594 158 0 0 0 0 0 0 1752
4 0.26199 1827.137 1448 168 136 0 0 0 0 0 1752
5 0.41105 2008.48 1384 144 136 88 0 0 0 0 1752
6 0.411066 1972.693 1384 146 136 86 0 0 0 0 1752
7 0.411082 1576.04 1376 148 136 39 0 0 53 0 1752
8 0.411098 1568.132 1376 148 136 37 0 0 55 0 1752
9 0.411114 1544.037 1375 149 136 31 0 0 61 0 1752
10 0.40107 1470.133 1375 149 136 31 0 0 61 0 1752
The Pushover Analysis – from basics Presented by Rahul Leslie
63
• For the performance point, taken as step 5 (which actually lies
between steps 4 and 5),
– 95% of hinges are within LS and IO performance levels
– 88% within IO performance level.
Example of a building analysis
Step
Δroof top
(m)
Vb
(kN)
Hinge States
Total
Hinges
A to
B
B to
IO
IO to
LS
LS to
CP
CP
to C
C to
D
D to
E > E
0 0 0 1752 0 0 0 0 0 0 0 1752
1 0.058318 1084.354 1748 4 0 0 0 0 0 0 1752
2 0.074442 1348.412 1670 82 0 0 0 0 0 0 1752
3 0.089645 1451.4 1594 158 0 0 0 0 0 0 1752
4 0.26199 1827.137 1448 168 136 0 0 0 0 0 1752
5 0.41105 2008.48 1384 144 136 88 0 0 0 0 1752
6 0.411066 1972.693 1384 146 136 86 0 0 0 0 1752
7 0.411082 1576.04 1376 148 136 39 0 0 53 0 1752
8 0.411098 1568.132 1376 148 136 37 0 0 55 0 1752
9 0.411114 1544.037 1375 149 136 31 0 0 61 0 1752
10 0.40107 1470.133 1375 149 136 31 0 0 61 0 1752
The Pushover Analysis – from basics Presented by Rahul Leslie
64
• Following figures shows the hinge states during various stages in
course of the analysis.
Example of a building analysis
Fig: Hinge states in the structure model at (a) step 0 & (b) step 3
The Pushover Analysis – from basics Presented by Rahul Leslie
65
• Following figures shows the hinge states during various stages in
course of the analysis.
Example of a building analysis
Fig: Hinge states in the structure model at (c) step 5 & (d) step 8
The Pushover Analysis – from basics Presented by Rahul Leslie
66
• Following figures shows the hinge states during various stages in
course of the analysis.
Example of a building analysis
Fig: Hinge states in the structure model at (e) step 10
The Pushover Analysis – from basics Presented by Rahul Leslie
67
• Hinge properties
– Determining hinge properties (beams, columns, diagonal struts)
– Determining hinge properties for flat-slab and shear walls
• Seismic analysis  design/detailing  hinge property
calculation  insertion of hinges  Pushover Analysis
– Doing the above manually at a practically acceptable speed
– Non-availability of a semi-automatic method in standard Analysis
Packages (STAAD, ETABS, etc.) :
Facility to quickly define details of provided
reinforcement bars for beams & columns and have the package
to automatically insert appropriately calculated hinges not
available.
Issues
The Pushover Analysis – from basics Presented by Rahul Leslie
68
• Inclusion of building torsion (no standardized guidelines
available)
• Inclusion of higher modes in PA
– PA with vectors that represent the effects of multiple modes
(FEMA 356)
– Explicit consideration of Multiple Modes
• Modal Pushover Analysis (Chopra and Goel, (2001).
• Incremental Response Spectrum Analysis (Aydinoglu, 2003)
• Consecutive Modal Pushover (Poursha et al., 2009)
– Progressive changes in the load vector pattern applied to the
structure.
• Displacement Adaptive Pushover (Antoniou and Pinho, 2004)
• IS:1893-2002 is yet to include the method
Limitations
The Pushover Analysis – from basics Presented by Rahul Leslie
69
References:
• IS 1893 (Part 1)–2002, “Indian Standard Criteria for Earthquake Resistant
Design of Structures, Part 1: General Provision and Buildings”, Bureau of
Indian Standards, New Delhi.
• FEMA 356 (2000) “Prestandard and Commentary for the Seismic Rehabilitation
of Buildings”, Federal Emergency Management Agency, Washington, DC, USA.
• ATC-40 (1996) “Seismic Analysis and Retrofit of Concrete Buildings”, vol. I,
Applied Technology Council, Redwood City, CA, USA.
• FEMA-440 (2005) “Improvement of Nonlinear static seismic analysis
procedures”, Federal Emergency Management Agency, Washington, DC, U.S.A.
• prEN 1998-1 (2003) “Eurocode 8 Part 1: Design of structures for earthquake
resistance”, European Committee for Standardization, Brussels.
• Jisha S. V. (2008), Mini Project Report “Pushover Analysis”, Department of Civil
Engineering, T. K. M. College of Engineering, Kollam, Kerala.
The Pushover Analysis – from basics Presented by Rahul Leslie
70
A write up on this topic can be found at …
http://rahulleslie.blogspot.in/p/blog-page.html
… but covers only the ATC-40 method of pushover
analysis.
Note
The Pushover Analysis – from basics Presented by Rahul Leslie
71
An effort has been made to present the topic as simple as
possible…
…presume, at least to some extend, the aim has been fulfilled.
Conclusion
Thank you
rahul.leslie@gmail.com

More Related Content

What's hot

Seismic Design Of Structures Project
Seismic Design Of Structures ProjectSeismic Design Of Structures Project
Seismic Design Of Structures ProjectGunjan Shetye
 
Seismic Analysis
Seismic AnalysisSeismic Analysis
Seismic AnalysisKrishnagnr
 
Design of columns biaxial bending as per IS 456-2000
Design of columns  biaxial bending as per IS 456-2000Design of columns  biaxial bending as per IS 456-2000
Design of columns biaxial bending as per IS 456-2000PraveenKumar Shanmugam
 
Etabs example-rc building seismic load response-
Etabs example-rc building seismic load  response-Etabs example-rc building seismic load  response-
Etabs example-rc building seismic load response-Bhaskar Alapati
 
Overview of Direct Analysis Method of Design for
Overview of Direct Analysis Method of Design forOverview of Direct Analysis Method of Design for
Overview of Direct Analysis Method of Design forRyan Brotherson
 
Etabs concrete-design
Etabs concrete-designEtabs concrete-design
Etabs concrete-designmamilli
 
Lec11 Continuous Beams and One Way Slabs(1) (Reinforced Concrete Design I & P...
Lec11 Continuous Beams and One Way Slabs(1) (Reinforced Concrete Design I & P...Lec11 Continuous Beams and One Way Slabs(1) (Reinforced Concrete Design I & P...
Lec11 Continuous Beams and One Way Slabs(1) (Reinforced Concrete Design I & P...Hossam Shafiq II
 
Basic concepts on structural dynamics
Basic concepts on structural dynamicsBasic concepts on structural dynamics
Basic concepts on structural dynamicsPrasad Raju
 
Design of columns axial load as per IS 456-2000
Design of columns  axial load as per IS 456-2000Design of columns  axial load as per IS 456-2000
Design of columns axial load as per IS 456-2000PraveenKumar Shanmugam
 
CE 72.52 - Lecture 8a - Retrofitting of RC Members
CE 72.52 - Lecture 8a - Retrofitting of RC MembersCE 72.52 - Lecture 8a - Retrofitting of RC Members
CE 72.52 - Lecture 8a - Retrofitting of RC MembersFawad Najam
 
ANALYSIS AND DESIGN OF HIGH RISE BUILDING BY USING ETABS
ANALYSIS AND DESIGN OF HIGH RISE BUILDING BY USING ETABSANALYSIS AND DESIGN OF HIGH RISE BUILDING BY USING ETABS
ANALYSIS AND DESIGN OF HIGH RISE BUILDING BY USING ETABSila vamsi krishna
 
Response Spectrum
Response SpectrumResponse Spectrum
Response SpectrumTeja Ande
 
Nonlinear Static Analysis (Pushover)
Nonlinear Static Analysis (Pushover)Nonlinear Static Analysis (Pushover)
Nonlinear Static Analysis (Pushover)FabioDiTrapani2
 

What's hot (20)

Seismic Design Of Structures Project
Seismic Design Of Structures ProjectSeismic Design Of Structures Project
Seismic Design Of Structures Project
 
Seismic Analysis
Seismic AnalysisSeismic Analysis
Seismic Analysis
 
Design of columns biaxial bending as per IS 456-2000
Design of columns  biaxial bending as per IS 456-2000Design of columns  biaxial bending as per IS 456-2000
Design of columns biaxial bending as per IS 456-2000
 
response spectra
response spectraresponse spectra
response spectra
 
Etabs example-rc building seismic load response-
Etabs example-rc building seismic load  response-Etabs example-rc building seismic load  response-
Etabs example-rc building seismic load response-
 
Design of columns as per IS 456-2000
Design of columns as per IS 456-2000Design of columns as per IS 456-2000
Design of columns as per IS 456-2000
 
Overview of Direct Analysis Method of Design for
Overview of Direct Analysis Method of Design forOverview of Direct Analysis Method of Design for
Overview of Direct Analysis Method of Design for
 
Etabs concrete-design
Etabs concrete-designEtabs concrete-design
Etabs concrete-design
 
Lec11 Continuous Beams and One Way Slabs(1) (Reinforced Concrete Design I & P...
Lec11 Continuous Beams and One Way Slabs(1) (Reinforced Concrete Design I & P...Lec11 Continuous Beams and One Way Slabs(1) (Reinforced Concrete Design I & P...
Lec11 Continuous Beams and One Way Slabs(1) (Reinforced Concrete Design I & P...
 
Design notes for seismic design of building accordance to Eurocode 8
Design notes for seismic design of building accordance to Eurocode 8 Design notes for seismic design of building accordance to Eurocode 8
Design notes for seismic design of building accordance to Eurocode 8
 
Basic concepts on structural dynamics
Basic concepts on structural dynamicsBasic concepts on structural dynamics
Basic concepts on structural dynamics
 
Design of footing as per IS 456-2000
Design of footing as per IS 456-2000Design of footing as per IS 456-2000
Design of footing as per IS 456-2000
 
Design of columns axial load as per IS 456-2000
Design of columns  axial load as per IS 456-2000Design of columns  axial load as per IS 456-2000
Design of columns axial load as per IS 456-2000
 
CE 72.52 - Lecture 8a - Retrofitting of RC Members
CE 72.52 - Lecture 8a - Retrofitting of RC MembersCE 72.52 - Lecture 8a - Retrofitting of RC Members
CE 72.52 - Lecture 8a - Retrofitting of RC Members
 
ANALYSIS AND DESIGN OF HIGH RISE BUILDING BY USING ETABS
ANALYSIS AND DESIGN OF HIGH RISE BUILDING BY USING ETABSANALYSIS AND DESIGN OF HIGH RISE BUILDING BY USING ETABS
ANALYSIS AND DESIGN OF HIGH RISE BUILDING BY USING ETABS
 
Response Spectrum
Response SpectrumResponse Spectrum
Response Spectrum
 
Nonlinear Static Analysis (Pushover)
Nonlinear Static Analysis (Pushover)Nonlinear Static Analysis (Pushover)
Nonlinear Static Analysis (Pushover)
 
Shear wall and its design guidelines
Shear wall and its design guidelinesShear wall and its design guidelines
Shear wall and its design guidelines
 
Etabs tutorial
Etabs tutorialEtabs tutorial
Etabs tutorial
 
Etabs (atkins)
Etabs (atkins)Etabs (atkins)
Etabs (atkins)
 

Similar to The Pushover Analysis from basics - Rahul Leslie

pushoveranalysisfrombasicsrahulleslie080216-160213015605.pptx
pushoveranalysisfrombasicsrahulleslie080216-160213015605.pptxpushoveranalysisfrombasicsrahulleslie080216-160213015605.pptx
pushoveranalysisfrombasicsrahulleslie080216-160213015605.pptxNeelamVerma656538
 
Performance of Flat Slab Structure Using Pushover Analysis
Performance of Flat Slab Structure Using Pushover AnalysisPerformance of Flat Slab Structure Using Pushover Analysis
Performance of Flat Slab Structure Using Pushover AnalysisIOSR Journals
 
Non Linear Analysis of RCC Building with and Without Shear Wall
Non Linear Analysis of RCC Building with and Without Shear WallNon Linear Analysis of RCC Building with and Without Shear Wall
Non Linear Analysis of RCC Building with and Without Shear WallIRJET Journal
 
Investigation on performance based non linear pushover analysis of flat plate...
Investigation on performance based non linear pushover analysis of flat plate...Investigation on performance based non linear pushover analysis of flat plate...
Investigation on performance based non linear pushover analysis of flat plate...Yousuf Dinar
 
Non Linear Static Analysis of Dual RC Frame Structure
Non Linear Static Analysis of Dual RC Frame StructureNon Linear Static Analysis of Dual RC Frame Structure
Non Linear Static Analysis of Dual RC Frame StructureIRJET Journal
 
Performance Based Design Presentation By Deepak Bashetty
Performance Based Design Presentation By Deepak BashettyPerformance Based Design Presentation By Deepak Bashetty
Performance Based Design Presentation By Deepak BashettyDeepak Bashetty
 
IRJET- Progrssive Collapse Analysis of RCC Stucture for Variable Heights on S...
IRJET- Progrssive Collapse Analysis of RCC Stucture for Variable Heights on S...IRJET- Progrssive Collapse Analysis of RCC Stucture for Variable Heights on S...
IRJET- Progrssive Collapse Analysis of RCC Stucture for Variable Heights on S...IRJET Journal
 
IRJET- Pushover Analysis on Reinforced Concrete Building using ETABS
IRJET- Pushover Analysis on Reinforced Concrete Building using ETABSIRJET- Pushover Analysis on Reinforced Concrete Building using ETABS
IRJET- Pushover Analysis on Reinforced Concrete Building using ETABSIRJET Journal
 
IRJET- Comparative Study on Conventional Slab and Flat Slabs RCC Structure us...
IRJET- Comparative Study on Conventional Slab and Flat Slabs RCC Structure us...IRJET- Comparative Study on Conventional Slab and Flat Slabs RCC Structure us...
IRJET- Comparative Study on Conventional Slab and Flat Slabs RCC Structure us...IRJET Journal
 
International Refereed Journal of Engineering and Science (IRJES)
International Refereed Journal of Engineering and Science (IRJES)International Refereed Journal of Engineering and Science (IRJES)
International Refereed Journal of Engineering and Science (IRJES)irjes
 
International Refereed Journal of Engineering and Science (IRJES)
International Refereed Journal of Engineering and Science (IRJES)International Refereed Journal of Engineering and Science (IRJES)
International Refereed Journal of Engineering and Science (IRJES)irjes
 
Performance based analysis of rc building consisting shear wall and varying i...
Performance based analysis of rc building consisting shear wall and varying i...Performance based analysis of rc building consisting shear wall and varying i...
Performance based analysis of rc building consisting shear wall and varying i...Yousuf Dinar
 
Descriptive study of pushover analysis in rcc structures of rigid joint
Descriptive study of pushover analysis in rcc structures of rigid jointDescriptive study of pushover analysis in rcc structures of rigid joint
Descriptive study of pushover analysis in rcc structures of rigid jointYousuf Dinar
 
Seismic Vulnerability of RC Building With and Without Soft Storey Effect Usi...
Seismic Vulnerability of RC Building With and Without Soft  Storey Effect Usi...Seismic Vulnerability of RC Building With and Without Soft  Storey Effect Usi...
Seismic Vulnerability of RC Building With and Without Soft Storey Effect Usi...IJMER
 
Pushover Analysis of Balance Cantilever Bridge
Pushover Analysis of Balance Cantilever BridgePushover Analysis of Balance Cantilever Bridge
Pushover Analysis of Balance Cantilever BridgeIRJET Journal
 
Effect of soft storeys in earthquake resistant analysis of rc framed structures
Effect of soft storeys in earthquake resistant analysis of rc framed structuresEffect of soft storeys in earthquake resistant analysis of rc framed structures
Effect of soft storeys in earthquake resistant analysis of rc framed structureseSAT Journals
 
IRJET- Seismic Behavior of RC Flat Slab with and without Shear Wall Techn...
IRJET-  	  Seismic Behavior of RC Flat Slab with and without Shear Wall Techn...IRJET-  	  Seismic Behavior of RC Flat Slab with and without Shear Wall Techn...
IRJET- Seismic Behavior of RC Flat Slab with and without Shear Wall Techn...IRJET Journal
 
Non-Linear Static Analysis of Reinforced Concrete Bridge
Non-Linear Static Analysis of Reinforced Concrete BridgeNon-Linear Static Analysis of Reinforced Concrete Bridge
Non-Linear Static Analysis of Reinforced Concrete BridgeIRJET Journal
 
SEISMIC ANALYSIS OF IRREGUAR (L-SHAPED) RCC BUILDING
SEISMIC ANALYSIS OF IRREGUAR (L-SHAPED) RCC BUILDINGSEISMIC ANALYSIS OF IRREGUAR (L-SHAPED) RCC BUILDING
SEISMIC ANALYSIS OF IRREGUAR (L-SHAPED) RCC BUILDINGJournal For Research
 

Similar to The Pushover Analysis from basics - Rahul Leslie (20)

pushoveranalysisfrombasicsrahulleslie080216-160213015605.pptx
pushoveranalysisfrombasicsrahulleslie080216-160213015605.pptxpushoveranalysisfrombasicsrahulleslie080216-160213015605.pptx
pushoveranalysisfrombasicsrahulleslie080216-160213015605.pptx
 
Performance of Flat Slab Structure Using Pushover Analysis
Performance of Flat Slab Structure Using Pushover AnalysisPerformance of Flat Slab Structure Using Pushover Analysis
Performance of Flat Slab Structure Using Pushover Analysis
 
Non Linear Analysis of RCC Building with and Without Shear Wall
Non Linear Analysis of RCC Building with and Without Shear WallNon Linear Analysis of RCC Building with and Without Shear Wall
Non Linear Analysis of RCC Building with and Without Shear Wall
 
Investigation on performance based non linear pushover analysis of flat plate...
Investigation on performance based non linear pushover analysis of flat plate...Investigation on performance based non linear pushover analysis of flat plate...
Investigation on performance based non linear pushover analysis of flat plate...
 
Non Linear Static Analysis of Dual RC Frame Structure
Non Linear Static Analysis of Dual RC Frame StructureNon Linear Static Analysis of Dual RC Frame Structure
Non Linear Static Analysis of Dual RC Frame Structure
 
Performance Based Design Presentation By Deepak Bashetty
Performance Based Design Presentation By Deepak BashettyPerformance Based Design Presentation By Deepak Bashetty
Performance Based Design Presentation By Deepak Bashetty
 
IRJET- Progrssive Collapse Analysis of RCC Stucture for Variable Heights on S...
IRJET- Progrssive Collapse Analysis of RCC Stucture for Variable Heights on S...IRJET- Progrssive Collapse Analysis of RCC Stucture for Variable Heights on S...
IRJET- Progrssive Collapse Analysis of RCC Stucture for Variable Heights on S...
 
IRJET- Pushover Analysis on Reinforced Concrete Building using ETABS
IRJET- Pushover Analysis on Reinforced Concrete Building using ETABSIRJET- Pushover Analysis on Reinforced Concrete Building using ETABS
IRJET- Pushover Analysis on Reinforced Concrete Building using ETABS
 
IRJET- Comparative Study on Conventional Slab and Flat Slabs RCC Structure us...
IRJET- Comparative Study on Conventional Slab and Flat Slabs RCC Structure us...IRJET- Comparative Study on Conventional Slab and Flat Slabs RCC Structure us...
IRJET- Comparative Study on Conventional Slab and Flat Slabs RCC Structure us...
 
International Refereed Journal of Engineering and Science (IRJES)
International Refereed Journal of Engineering and Science (IRJES)International Refereed Journal of Engineering and Science (IRJES)
International Refereed Journal of Engineering and Science (IRJES)
 
International Refereed Journal of Engineering and Science (IRJES)
International Refereed Journal of Engineering and Science (IRJES)International Refereed Journal of Engineering and Science (IRJES)
International Refereed Journal of Engineering and Science (IRJES)
 
Performance based analysis of rc building consisting shear wall and varying i...
Performance based analysis of rc building consisting shear wall and varying i...Performance based analysis of rc building consisting shear wall and varying i...
Performance based analysis of rc building consisting shear wall and varying i...
 
Descriptive study of pushover analysis in rcc structures of rigid joint
Descriptive study of pushover analysis in rcc structures of rigid jointDescriptive study of pushover analysis in rcc structures of rigid joint
Descriptive study of pushover analysis in rcc structures of rigid joint
 
Seismic Vulnerability of RC Building With and Without Soft Storey Effect Usi...
Seismic Vulnerability of RC Building With and Without Soft  Storey Effect Usi...Seismic Vulnerability of RC Building With and Without Soft  Storey Effect Usi...
Seismic Vulnerability of RC Building With and Without Soft Storey Effect Usi...
 
Pushover Analysis of Balance Cantilever Bridge
Pushover Analysis of Balance Cantilever BridgePushover Analysis of Balance Cantilever Bridge
Pushover Analysis of Balance Cantilever Bridge
 
F012515059
F012515059F012515059
F012515059
 
Effect of soft storeys in earthquake resistant analysis of rc framed structures
Effect of soft storeys in earthquake resistant analysis of rc framed structuresEffect of soft storeys in earthquake resistant analysis of rc framed structures
Effect of soft storeys in earthquake resistant analysis of rc framed structures
 
IRJET- Seismic Behavior of RC Flat Slab with and without Shear Wall Techn...
IRJET-  	  Seismic Behavior of RC Flat Slab with and without Shear Wall Techn...IRJET-  	  Seismic Behavior of RC Flat Slab with and without Shear Wall Techn...
IRJET- Seismic Behavior of RC Flat Slab with and without Shear Wall Techn...
 
Non-Linear Static Analysis of Reinforced Concrete Bridge
Non-Linear Static Analysis of Reinforced Concrete BridgeNon-Linear Static Analysis of Reinforced Concrete Bridge
Non-Linear Static Analysis of Reinforced Concrete Bridge
 
SEISMIC ANALYSIS OF IRREGUAR (L-SHAPED) RCC BUILDING
SEISMIC ANALYSIS OF IRREGUAR (L-SHAPED) RCC BUILDINGSEISMIC ANALYSIS OF IRREGUAR (L-SHAPED) RCC BUILDING
SEISMIC ANALYSIS OF IRREGUAR (L-SHAPED) RCC BUILDING
 

Recently uploaded

Thermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VThermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VDineshKumar4165
 
Thermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.pptThermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.pptDineshKumar4165
 
Call Girls Wakad Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Wakad Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Wakad Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Wakad Call Me 7737669865 Budget Friendly No Advance Bookingroncy bisnoi
 
Unit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdfUnit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdfRagavanV2
 
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete RecordCCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete RecordAsst.prof M.Gokilavani
 
Bhosari ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...
Bhosari ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...Bhosari ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...
Bhosari ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...tanu pandey
 
notes on Evolution Of Analytic Scalability.ppt
notes on Evolution Of Analytic Scalability.pptnotes on Evolution Of Analytic Scalability.ppt
notes on Evolution Of Analytic Scalability.pptMsecMca
 
Top Rated Call Girls In chittoor 📱 {7001035870} VIP Escorts chittoor
Top Rated Call Girls In chittoor 📱 {7001035870} VIP Escorts chittoorTop Rated Call Girls In chittoor 📱 {7001035870} VIP Escorts chittoor
Top Rated Call Girls In chittoor 📱 {7001035870} VIP Escorts chittoordharasingh5698
 
chapter 5.pptx: drainage and irrigation engineering
chapter 5.pptx: drainage and irrigation engineeringchapter 5.pptx: drainage and irrigation engineering
chapter 5.pptx: drainage and irrigation engineeringmulugeta48
 
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...Call Girls in Nagpur High Profile
 
Block diagram reduction techniques in control systems.ppt
Block diagram reduction techniques in control systems.pptBlock diagram reduction techniques in control systems.ppt
Block diagram reduction techniques in control systems.pptNANDHAKUMARA10
 
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXssuser89054b
 
University management System project report..pdf
University management System project report..pdfUniversity management System project report..pdf
University management System project report..pdfKamal Acharya
 
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night StandCall Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Standamitlee9823
 
KubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghlyKubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghlysanyuktamishra911
 
data_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdfdata_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdfJiananWang21
 

Recently uploaded (20)

Thermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VThermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - V
 
Thermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.pptThermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.ppt
 
Call Girls Wakad Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Wakad Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Wakad Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Wakad Call Me 7737669865 Budget Friendly No Advance Booking
 
Unit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdfUnit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdf
 
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete RecordCCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
 
Bhosari ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...
Bhosari ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...Bhosari ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...
Bhosari ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...
 
notes on Evolution Of Analytic Scalability.ppt
notes on Evolution Of Analytic Scalability.pptnotes on Evolution Of Analytic Scalability.ppt
notes on Evolution Of Analytic Scalability.ppt
 
Call Girls in Netaji Nagar, Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
Call Girls in Netaji Nagar, Delhi 💯 Call Us 🔝9953056974 🔝 Escort ServiceCall Girls in Netaji Nagar, Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
Call Girls in Netaji Nagar, Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
 
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
 
Top Rated Call Girls In chittoor 📱 {7001035870} VIP Escorts chittoor
Top Rated Call Girls In chittoor 📱 {7001035870} VIP Escorts chittoorTop Rated Call Girls In chittoor 📱 {7001035870} VIP Escorts chittoor
Top Rated Call Girls In chittoor 📱 {7001035870} VIP Escorts chittoor
 
chapter 5.pptx: drainage and irrigation engineering
chapter 5.pptx: drainage and irrigation engineeringchapter 5.pptx: drainage and irrigation engineering
chapter 5.pptx: drainage and irrigation engineering
 
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak HamilCara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
 
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...
 
Block diagram reduction techniques in control systems.ppt
Block diagram reduction techniques in control systems.pptBlock diagram reduction techniques in control systems.ppt
Block diagram reduction techniques in control systems.ppt
 
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
 
Water Industry Process Automation & Control Monthly - April 2024
Water Industry Process Automation & Control Monthly - April 2024Water Industry Process Automation & Control Monthly - April 2024
Water Industry Process Automation & Control Monthly - April 2024
 
University management System project report..pdf
University management System project report..pdfUniversity management System project report..pdf
University management System project report..pdf
 
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night StandCall Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
 
KubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghlyKubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghly
 
data_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdfdata_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdf
 

The Pushover Analysis from basics - Rahul Leslie

  • 1. 1 The Pushover Analysis – from basics Presented by . Rahul Leslie Assistant Director, Buildings Design, DRIQ, Kerala PWD, Trivandrum, India
  • 2. 2 Introduction • Performance Based Design --- an emerging field – To provide engineers with a capability to design buildings that have predictable and reliable performance in earthquakes – It employs concept of ‘performance objectives’, which is the specification of an acceptable level of damage on experiencing a earthquake of a given severity. (FEMA 349) • Seismic design for the future – Presently a linear elastic analysis alone is sufficient for both its elastic and ductile design – In course of time, for large critical structures, a specially dedicated non- linear procedure will have to be done, which finally influences the seismic design as a whole. The Pushover Analysis – from basics Presented by Rahul Leslie
  • 3. 3 Introduction • Linear approach (IS:1893-2002) is based on the Response Reduction factor R. – For example, R = 5, means that 1/5th of the seismic force is taken by the Limit State capacity of the structure. – Further deflection is taken by the ductile capacity of the structure. – Reinforced Concrete (RC) members are detailed (as per IS:13920) to confirm its ductile capacity. – We never analyse for the ductile part, but only follow the reinforcement detailing guidelines for the same. The Pushover Analysis – from basics Presented by Rahul Leslie
  • 4. 4 Introduction • The drawback is that the response beyond the limit state is neither a simple extrapolation, … • … nor a perfectly ductile behaviour with pre-determinable deformation capacity, due to various reasons: – Change in stiffness of members due to cracking and yielding, – P-delta effects, – Change in the final seismic force estimated (due to Change in • time period ‘T’ and • effective damping ratio ‘ζ’ (also represented by ‘β’) – etc. The Pushover Analysis – from basics Presented by Rahul Leslie
  • 5. 5 Introduction • Although elastic analysis gives a good indication of elastic capacity of structures and shows where yielding will first occur, – It cannot predict the redistribution of forces during the progressive yielding that follows and predict its failure mechanisms. • A non-linear static analysis can predict these more accurately. – It can help identify members likely to reach critical states during an earthquake for which attention should be given during design and detailing. The Pushover Analysis – from basics Presented by Rahul Leslie
  • 6. 6 Introduction The Pushover Analysis (PA): • PA is a non-linear analysis procedure to estimate the strength capacity of a structure beyond its Limit State up to its ultimate strength. • It can help demonstrate how progressive failure in buildings most probably occurs, and identify the mode of final failure. • The method also predicts potential weak areas in the structure, by keeping track of the sequence of damages of each and every member in the structure. The Pushover Analysis – from basics Presented by Rahul Leslie
  • 7. 7 PA can be useful under two situations:  When an existing structure has deficiencies in seismic resisting capacity,  due to either omission of seismic design when built, or  the structure becoming seismically inadequate due to a later upgradation of the seismic codes, is to be retrofitted to meet the (present) seismic demands, PA can show where the retrofitting is required and how much.  For a building in its design phase, PA results help scrutinise and fine tune the seismic design based on SA. Introduction The Pushover Analysis – from basics Presented by Rahul Leslie
  • 8. 8 • For a new building, PA is meant to be a second stage analysis (The first stage being a conventional Seismic analysis - SA). • This is because the details of reinforcement provided are required to calculate exact hinge properties (to be covered later) • But one has to design the structure based on SA in order to obtain the reinforcement details. • This means that PA is meant to be a second stage analysis (The first stage being a conventional SA). • Thus the emerging methodology to an accurate seismic design is: 1. First a conventional linear seismic analysis based on which a primary structural design is done; 2. Insertion of hinges determined based on the design/detail and then 3. A pushover analysis is done, followed by 4. Modification of the design and detailing, wherever necessary, based on the latter analysis. 5. The above steps may have to be iterated, if required. Introduction The Pushover Analysis – from basics Presented by Rahul Leslie
  • 9. 9 Features of a Typical Pushover Approach • The model, which is a Multi-degree of freedom (MDoF) model, is used for the analysis There are certain features common to all PA approaches: 1. An analysis model of the building, is generated using a common analysis-design software package (having facility for PA), like – STAAD.Pro, – SAP2000, ETABS, – MIDAS/Gen, etc. The Pushover Analysis – from basics Presented by Rahul Leslie
  • 10. 10 Non-linear Building model & Non-linear Hinges Pushover analysis uses a non-linear computer model for the analysis: – This is done by incorporated in the form of non-linear hinges inserted into an otherwise linear elastic model which one generates using a common analysis-design software package (STAAD.Pro, SAP2000, ETABS, MIDAS/Gen, etc.) – Hinges are points on a structure where one expects cracking and yielding to occur in relatively higher intensity so that they show higher flexural/shear displacement, under a cyclic loading The Pushover Analysis – from basics Presented by Rahul Leslie
  • 11. 11 - These are locations where one expects to see cross diagonal cracks in an actual building structure after a seismic mayhem – they would be at either ends of beams and columns, the ‘cross’ being at a small distance from the joint – this is where one inserts hinges in the corresponding computer model. Non-linear Building model & Non-linear Hinges The Pushover Analysis – from basics Presented by Rahul Leslie
  • 12. 12 • Basically a hinge represents localised force-displacement relation of a member through its elastic and inelastic phases under seismic loads. • A flexural hinge represents the moment-rotation relation of a beam. • Hinges are of various types – namely, – (1) flexural hinges, – (2) shear hinges – (3) axial hinges. Non-linear Building model & Non-linear Hinges The Pushover Analysis – from basics Presented by Rahul Leslie
  • 13. 13 • The flexural and shear hinges are inserted into the ends of beams and columns. • Since the presence of masonry infills have significant influence on the seismic behaviour of the structure, modelling them using equivalent diagonal struts (of ‘truss’ elements) is common in PA • The axial hinges are inserted at either ends of the diagonal struts Non-linear Building model & Non-linear Hinges The Pushover Analysis – from basics Presented by Rahul Leslie
  • 14. 14 Typical Moment Hinge property: • AB represents the linear range from unloaded state (A) to its effective yield (B), • Followed by an inelastic but linear response of reduced (ductile) stiffness from B to C. • CD shows a sudden reduction in load resistance, followed by a reduced resistance from D to E, and • finally a total loss of resistance from E to F. Flexural Hinge Non-linear Building model & Non-linear Hinges The Pushover Analysis – from basics Presented by Rahul Leslie
  • 15. 15 • These hinges have non-linear states defined within its ductile range as – ‘Immediate Occupancy’ (IO), – ‘Life Safety’ (LS) and – ‘Collapse Prevention’ (CP) • This is usually done by dividing B-C into four parts and denoting IO, LS and CP, which are states of each individual hinges Flexural Hinge Non-linear Building model & Non-linear Hinges The Pushover Analysis – from basics Presented by Rahul Leslie
  • 16. 16 There are certain features common to all PA approaches: 2. The model is pushed monotonically with an invariable distribution of lateral load with some predefined distribution pattern such as: – Proportional to 1st mode (or SRSS combination of modes) – Inverted triangle / Uniform distribution – Power distribution (for example, parabolic) ∑ = n i k jj k ii bi hW hW VQ Features of a Typical Pushover Approach The Pushover Analysis – from basics Presented by Rahul Leslie
  • 17. 17 There are certain features common to all PA approaches: 2. (Continuation …) • Unlike conventional SA, in Pushover analysis, analysis for Gravity loads is done first, continued by an analysis for Lateral loads. • Since PA is done to simulate the behaviour under actual loads, the Gravity loads applied are not factored, but in accordance with Cl.7.3.3 and Table 8 of IS:1893-2002 : [DL + 0.25 LL≤3kN/sq.m + 0.5 LL>3kN/sq.m] Features of a Typical Pushover Approach The Pushover Analysis – from basics Presented by Rahul Leslie
  • 18. 18 3. A pushover curve is obtained, which is a Base shear (Vb) vs. Roof top displacement (Δrt) curve – Base shear is sum of all horizontal support reactions in that direction – Roof top displacement is the displacement at the centre of mass of the general roof Features of a Typical Pushover Approach The Pushover Analysis – from basics Presented by Rahul Leslie
  • 19. 19 4. A single-degree of freedom (SDoF) model, corresponding to the MDoF model, and the rules to convert the parameters of the MDoF model (Vb & Δrt) to those of the SDoF model (Sa & Sd) are defined Features of a Typical Pushover Approach The Pushover Analysis – from basics Presented by Rahul Leslie
  • 20. 20 4. (Continuation…) A single-degree of freedom (SDoF) model, corresponding to the MDoF model, and the rules to convert the parameters of the MDoF model (Vb & Δrt) to those of the SDoF model (Sa & Sd) are defined – In ATC-40 and FEMA440, the conversion is (where ), and – In EC 8 (where Sa and Sd are denoted by F* and d* respectively) and α WV Sa b / = M Mk 1= =α rtkkP rt Sd @,11 == ⋅ ∆ = φ 1= = k b P V Sa 1= ∆ = kP rt Sd Features of a Typical Pushover Approach The Pushover Analysis – from basics Presented by Rahul Leslie
  • 21. 21 5. The Sa-Sd curve has to be converted to an equivalent bi-linear curve (equal energy) by a suitable method – Different codes follow different methods ATC-40 and FEMA440 – ATC-40 and FEMA440 follows the method of keeping the 1st line as initial tangent stiffness and adjusts the 2nd line (to the point under consideration) such that to get the ‘equal area’. Features of a Typical Pushover Approach The Pushover Analysis – from basics Presented by Rahul Leslie
  • 22. 22 5. The Sa-Sd curve has to be converted to an equivalent bi-linear curve (equal energy) by a suitable method – Different codes follow different methods EC 8 – EC8 (EuroCode 8) follows the method of keeping the 2nd line (to the point under consideration) as ‘perfectly plastic’, ie., horizontal and adjusts the 1st line such that to get the ‘equal area’. Features of a Typical Pushover Approach The Pushover Analysis – from basics Presented by Rahul Leslie
  • 23. 23 5. The Sa-Sd curve has to be converted to an equivalent bi-linear curve (equal energy) by a suitable method – Different codes follow different methods ATC-40 and FEMA440 EC8 Features of a Typical Pushover Approach The Pushover Analysis – from basics Presented by Rahul Leslie
  • 24. 24 PA procedures can generally be classified to two: 1. DCM (Displacement Coeff. Method): These procedures estimates a Target displacement prior to the analysis, to which the model has to be pushed, and on analysis, checked for the intended (good) performance at that displacement. The method is nevertheless, iterative. Ref:- - FEMA356, - FEMA440 (Ch.5), - EC 8 2. CSM (Capacity Spectrum Method): The analysis is done, and each pt. on the pushover curve (known as Capacity curve) is consecutively checked to see whether the Sa-Sd at that pt. meets (or intersects) the Response Spectrum curve (known as Demand curve), reduced by a factor. (continued…) Different Pushover Approaches The Pushover Analysis – from basics Presented by Rahul Leslie
  • 25. 25 PA procedures can generally be classified to two: 2. CSM : … For each point on the Capacity curve, the Demand curve to be checked with, for intersection, is a Response Spectrum curve reduced by a reduction factor calculated corresponding to that point under consideration on the Capacity curve. When the curves intersects (or meet), that meeting point is known as the Performance Pt. Ref:- - ATC-40, - FEMA440 (Ch.6) - EC8 (Optional method) Different Pushover Approaches The Pushover Analysis – from basics Presented by Rahul Leslie
  • 26. 26 The steps for the CSM method are: 1. First, the Response Spectrum (RS) curve has to be modified: from its ordinates of Sa vs. Time period ‘T’, to its ‘Acceleration Displacement Response Spectrum’ (ADRS) form, which is an Sa vs. Sd curve. • This to facilitate the super-imposing the pushover curve over the RS (which is in its ADRS form) RS ADRS Steps for CSM method of Pushover Analysis The Pushover Analysis – from basics Presented by Rahul Leslie
  • 27. 27 The steps for the CSM method are: 1. First, the Response Spectrum (RS) curve has to be modified: from its ordinates of Sa vs. Time period, to its ‘Acceleration Displacement Response Spectrum’ (ADRS) form, which is an Sa vs. Sd curve. • This is done by using the relation RS ADRS Sa T Sd 2 2 4π = Steps for CSM method of Pushover Analysis The Pushover Analysis – from basics Presented by Rahul Leslie
  • 28. 28 2. Super-impose the converted Pushover curve on the ADRS curve: Steps for CSM method of Pushover Analysis The Pushover Analysis – from basics Presented by Rahul Leslie
  • 29. 29 3. With the Capacity curve (Pushover curve) superimposed on the Demand curve (ADRS), each point on the former is consecutively checked to : i. Get the yield point ordinates (Say & Sdy) ii. Calculate the ductility μ and the 2nd tangent stiffness coeff. α ATC-40, FEMA440 EC8 Steps for CSM method of Pushover Analysis The Pushover Analysis – from basics Presented by Rahul Leslie
  • 30. 30 iii. Determine the reduced ADRS for the above parameters corresponding to that pt. on the Capacity curve as:  ATC-40/FEMA440 : Calculate damping β from ductility μ and 2nd tangent stiffness coefficient α. Reduce ADRS corresponding to β  EC 8 : Reduce ADRS corresponding to ductility μ ATC-40, FEMA440 EC8 Steps for CSM method of Pushover Analysis The Pushover Analysis – from basics Presented by Rahul Leslie
  • 31. 31 • For example, in ATC-40, for the reduction of the Demand (ADRS) curve, the ‘effective’ damping ratio β is determined from the formula : Steps for CSM method of Pushover Analysis y p d d =µ ( )( ) ( )ααµπµ αµ κβ −+ −− += 1 112 05.0eff init nd K K2 =α y y init d a K = yp yp nd dd aa K − − =2 The Pushover Analysis – from basics Presented by Rahul Leslie
  • 32. 32 • …where the Damping Modification Factor κ is determined from the building type Table : Structural behaviour types Table : Values for Damping Modification Factor κ Shaking Duration Essentially New Building Average Existing Building Poor Existing Building Short Type A Type B Type C Long Type B Type C Type C Structure behaviou r type βeq(%) κ Type A ≤16.25 1.0 >16.25 Type B ≤25 0.67 >25 Type C Any value 0.33 ( ) 02/51.013.1 βπ− ( ) 02/446.0845.0 βπ− Steps for CSM method of Pushover Analysis ( )( ) ( )ααµπµ αµ κβ −+ −− += 1 112 05.0eff The Pushover Analysis – from basics Presented by Rahul Leslie
  • 33. 33 ( ) 12.2 681.021.3 (%)effeLog SRa β− = ( ) 65.1 41.031.2 (%)effeLog SRv β− = • From the effective damping ratio β, the factors for reducing the ADRS curve are determined from the formula : Steps for CSM method of Pushover Analysis The Pushover Analysis – from basics Presented by Rahul Leslie
  • 34. 34 4. Include the reduced ADRS Demand curve in the super-imposed graph: Steps for CSM method of Pushover Analysis The Pushover Analysis – from basics Presented by Rahul Leslie
  • 35. 35 Step by step through each method 1. The conventional SA procedure is explained to highlight the difference in approaches between SA & PA 2. Trace the progress of a PA from beginning to end, • both demonstrates plots of Vb vs Δroof top and RS curve in its – separate and uncombined form and – also their transformed and super-positioned ADRS plot. The Pushover Analysis – from basics Presented by Rahul Leslie
  • 36. 36 • In SA, the maximum DBE force acting on the structure is Z/2.(Sa/g), (assuming I = 1) with Sa/g corresponding to the estimated time period. • Its envelop is the RS curve marked q • The RS curve for the Limit State design is plotted in terms of Z/2R. (Sa/g), and is marked as curve p. Step by step through each method -- SA Method The Pushover Analysis – from basics Presented by Rahul Leslie
  • 37. 37 • Fig. shows the Vb vs Δroof top displacement. – The point P represents the Vb and Δroof top for the design lateral load (ie., of 1/R times full load) – The point Q represents the same for the full load, had the building been fully elastic – Point Q' for a perfectly-elastic perfectly-ductile structure. – The slope of the line OP represents the stiffness of the structure in a global sense. Since the analysis is linear, the stiffness remains same throughout the analysis, with Q being an extension of OP. Step by step through each method -- SA Method The Pushover Analysis – from basics Presented by Rahul Leslie
  • 38. 38 Step by step through each method -- SA Method • The same is represented in Fig.(left) where, for the time period Tp of the structure, – the full load is represented by Q (Saq), and – the design load by P (Sap). The Pushover Analysis – from basics Presented by Rahul Leslie
  • 39. 39 Step by step through each method -- SA Method • The ADRS representation of SA is as in Fig.(left). – the full load is represented by Q (Saq), – the design load by P (Sap). The Pushover Analysis – from basics Presented by Rahul Leslie
  • 40. 40 Step by step through each method -- PA Method Now we shall see how differently the PA approaches the same scenario :- • The segment OA in Fig.(left) is equivalent to OP in Fig.(right), with the slope representing the global stiffness in its elastic range. The Pushover Analysis – from basics Presented by Rahul Leslie
  • 41. 41 Step by step through each method -- PA Method The RS curve : Segment OA has time period Ta, curve ‘a’ representing the RS curve and Saa is the lateral load demand, in its elastic range. The Pushover Analysis – from basics Presented by Rahul Leslie
  • 42. 42 Step by step through each method -- PA Method • ADRS representation: The Pushover Analysis – from basics Presented by Rahul Leslie
  • 43. 43 Step by step through each method -- PA Method • As the analysis progresses, the lateral load is monotonically increased beyond its elastic limit of A, and the first hinges are formed. This decreases the overall stiffness of the structure. This is represented by the segment AB. • The decrease in slope of OB from that of OA shows the change in secant stiffness. The Pushover Analysis – from basics Presented by Rahul Leslie
  • 44. 44 Step by step through each method -- PA Method • The first hinges are formed, decreasing the overall stiffness of the structure, which in turn increases T and β, represented by point B in the plots. The Pushover Analysis – from basics Presented by Rahul Leslie
  • 45. 45 Step by step through each method -- PA Method • The change in the x-axis value of point B from that of point A shows the shift of time period from Ta to Tb. • The increase in β of the structure calls for a corresponding decrease in the RS curve, reduced by a factor calculated from β, which has thus come down from curve a to b. The Pushover Analysis – from basics Presented by Rahul Leslie
  • 46. 46 Step by step through each method -- PA Method • ADRS representation: Note the angular shift from Ta to Tb . • The increase in β of the structure calls for a corresponding decrease in the RS curve, reduced by a factor calculated from β, which has thus come down from curve a to b. The Pushover Analysis – from basics Presented by Rahul Leslie
  • 47. 47 Step by step through each method -- PA Method • As the lateral load is further increased monotonically, more hinges are formed and the existing hinges have further yielded in its non-linear phase represented by point C • This has further reduced the stiffness (the slope of OC), The Pushover Analysis – from basics Presented by Rahul Leslie
  • 48. 48 Step by step through each method -- PA Method • (Here are the two graphs overlapped – a possibility The Pushover Analysis – from basics Presented by Rahul Leslie
  • 49. 49 Step by step through each method -- PA Method • This has further reduced the stiffness, and increased T (from Tb to Tc). The Pushover Analysis – from basics Presented by Rahul Leslie
  • 50. 50 Step by step through each method -- PA Method • More hinges are formed and the existing hinges have further yielded in its non-linear phase, represented by point C • Note the angular shift from Tb to Tc. The Pushover Analysis – from basics Presented by Rahul Leslie
  • 51. 51 Step by step through each method -- PA Method • Here the point C is where the capacity curve OABC extending upwards meets the demand curve in, which was simultaneously descending down to curve c. • Thus C is the point where the total lateral force expected Sac is same as the lateral force applied ~Vbc • This point is known as the performance point. The Pushover Analysis – from basics Presented by Rahul Leslie
  • 52. 52 Step by step through each method -- PA Method • It is also defined as the point where the ‘locus of the performance point’, the line connecting Saa, Sab and Sac, intersects the capacity curve The Pushover Analysis – from basics Presented by Rahul Leslie
  • 53. 53 PA Method – Reviewing results • Once the performance point is found, the overall performance of the structure can be checked to see whether it matches the required performance level, based on inter-storey drift limits specified in ATC- 40, which are – 0.01h for IO, – 0.02h for LS, and – 0.33(Vb/W)∙h for CP, (h = height of the building). • The performance level is based on the importance and function of the building. For example, hospitals and emergency services buildings are expected to meet a performance level of IO. The Pushover Analysis – from basics Presented by Rahul Leslie
  • 54. 54 • The next step is to review the hinge formations at performance point. One can see the individual stage of each hinge, at its location. • Tables are obtained showing the number of hinges in each state, at each stage, based on which one decides which all beams and columns to be redesigned. • The decision depends whether the most severely yielded hinges are formed in beams or in columns, whether they are concentrated in a particular storey denoting soft story, and so on. PA Method – Reviewing results OA AB BC The Pushover Analysis – from basics Presented by Rahul Leslie
  • 55. 55 Adaptation for the Indian Code Adapting of Pushover Analysis (PA) for IS:1893-2002 • The PA has not been introduced in the Indian Standard code yet. However the procedure described in ATC-40 can be adapted for the seismic parameters of IS:1893-2002. • The RS curve in ATC-40 is described by parameters – Ca and – Cv, where the curve just as in IS:1893, is having a flat portion of intensity 2.5 Ca and a downward sloping portion described by Cv/T. Resp. Spec (ATC-40) The Pushover Analysis – from basics Presented by Rahul Leslie
  • 56. 56 • The seismic force in IS:1893- 2000 is represented by (ZI/2R).(Sa/g), where Sa/g is obtained from the RS curve, which in our code is represented by – 2.5 in the flat portion & – the downward sloping portion by • 1/T for hard soil, • 1.36/T for medium soil and • 1.67/T for soft soil. Resp. Spec (IS:1893-2002)       = g Sa R ZI Ah 2 Adaptation for the Indian Code The Pushover Analysis – from basics Presented by Rahul Leslie
  • 57. 57 • On comparison it can be inferred that – Ca = Z/2 and – Cv = Z/2 for hard, 1.36∙Z/2 for medium and 1.67∙Z/2 for soft soil • Here ‘I’ is not considered, since in PA, the criteria of importance of the structure is taken care of by the performance levels (IO, LS & CP) • R is also not considered since PA is always done for the full lateral load. Resp. Spec (ATC-40) Resp. Spec (IS:1893-2002)       =      = g SaZ g Sa R ZI Ah 22 Adaptation for the Indian Code The Pushover Analysis – from basics Presented by Rahul Leslie
  • 58. 58 • The ‘Limit State’ inter-storey drift limit specified in IS:1893-2002, being 0.004, when accounted for – R = 5 for ductile design and – I = 1.5 for important structures (IO performance level) = 1.0 for ordinary structures (LS performance level) gives 0.004∙R/I = 0.02 and 0.0133 for IO and LS respectively • The drift limit can be compared with those specified in ATC-40 (0.01 and 0.02 for IO and LS respectively). The limit for IO in IS:1893-2002 is more relaxed than that in ATC-40. • This 0.004∙R/I can be taken as the IS:1893-2002 limits for pushover drift, where I takes the values corresponding to Important and Ordinary structures for limits of IO and LS respectively. Adaptation for the Indian Code The Pushover Analysis – from basics Presented by Rahul Leslie
  • 59. 59 • Presented in this section are the results of a pushover analysis done on a 10 storey RCC building of a shopping complex using the structural package of SAP2000. Example of a building analysis The Pushover Analysis – from basics Presented by Rahul Leslie
  • 60. 60 • In the model, beams and columns were modelled using frame elements, into which the hinges were inserted. • Diaphragm action was assigned to the floor slabs to ensure integral lateral action of beams in each floor. • Although analysis was done in both transverse and longitudinal directions, only the results of the former are discussed here. • The lateral load was applied in pattern of that of the 1st mode shape in the transverse direction of the building, with an intensity for DBE as per IS:1893-2002, corresponding to zone-III in hard soil. Example of a building analysis The Pushover Analysis – from basics Presented by Rahul Leslie
  • 61. 61 • The ADRS plot shows the Sa and Sd at performance point as 0.085g and 0.242m. • The corresponding Vb and Δroof top are 1857.046 kN and 0.287m. The value of effective T is 3.368s. • The effective β at that level of the demand curve which met the performance point is 26%. Example of a building analysis The Pushover Analysis – from basics Presented by Rahul Leslie
  • 62. 62 Example of a building analysis • Table shows the hinge state details at each step of the analysis. Step Δroof top (m) Vb (kN) Hinge States Total Hinges A to B B to IO IO to LS LS to CP CP to C C to D D to E > E 0 0 0 1752 0 0 0 0 0 0 0 1752 1 0.058318 1084.354 1748 4 0 0 0 0 0 0 1752 2 0.074442 1348.412 1670 82 0 0 0 0 0 0 1752 3 0.089645 1451.4 1594 158 0 0 0 0 0 0 1752 4 0.26199 1827.137 1448 168 136 0 0 0 0 0 1752 5 0.41105 2008.48 1384 144 136 88 0 0 0 0 1752 6 0.411066 1972.693 1384 146 136 86 0 0 0 0 1752 7 0.411082 1576.04 1376 148 136 39 0 0 53 0 1752 8 0.411098 1568.132 1376 148 136 37 0 0 55 0 1752 9 0.411114 1544.037 1375 149 136 31 0 0 61 0 1752 10 0.40107 1470.133 1375 149 136 31 0 0 61 0 1752 The Pushover Analysis – from basics Presented by Rahul Leslie
  • 63. 63 • For the performance point, taken as step 5 (which actually lies between steps 4 and 5), – 95% of hinges are within LS and IO performance levels – 88% within IO performance level. Example of a building analysis Step Δroof top (m) Vb (kN) Hinge States Total Hinges A to B B to IO IO to LS LS to CP CP to C C to D D to E > E 0 0 0 1752 0 0 0 0 0 0 0 1752 1 0.058318 1084.354 1748 4 0 0 0 0 0 0 1752 2 0.074442 1348.412 1670 82 0 0 0 0 0 0 1752 3 0.089645 1451.4 1594 158 0 0 0 0 0 0 1752 4 0.26199 1827.137 1448 168 136 0 0 0 0 0 1752 5 0.41105 2008.48 1384 144 136 88 0 0 0 0 1752 6 0.411066 1972.693 1384 146 136 86 0 0 0 0 1752 7 0.411082 1576.04 1376 148 136 39 0 0 53 0 1752 8 0.411098 1568.132 1376 148 136 37 0 0 55 0 1752 9 0.411114 1544.037 1375 149 136 31 0 0 61 0 1752 10 0.40107 1470.133 1375 149 136 31 0 0 61 0 1752 The Pushover Analysis – from basics Presented by Rahul Leslie
  • 64. 64 • Following figures shows the hinge states during various stages in course of the analysis. Example of a building analysis Fig: Hinge states in the structure model at (a) step 0 & (b) step 3 The Pushover Analysis – from basics Presented by Rahul Leslie
  • 65. 65 • Following figures shows the hinge states during various stages in course of the analysis. Example of a building analysis Fig: Hinge states in the structure model at (c) step 5 & (d) step 8 The Pushover Analysis – from basics Presented by Rahul Leslie
  • 66. 66 • Following figures shows the hinge states during various stages in course of the analysis. Example of a building analysis Fig: Hinge states in the structure model at (e) step 10 The Pushover Analysis – from basics Presented by Rahul Leslie
  • 67. 67 • Hinge properties – Determining hinge properties (beams, columns, diagonal struts) – Determining hinge properties for flat-slab and shear walls • Seismic analysis  design/detailing  hinge property calculation  insertion of hinges  Pushover Analysis – Doing the above manually at a practically acceptable speed – Non-availability of a semi-automatic method in standard Analysis Packages (STAAD, ETABS, etc.) : Facility to quickly define details of provided reinforcement bars for beams & columns and have the package to automatically insert appropriately calculated hinges not available. Issues The Pushover Analysis – from basics Presented by Rahul Leslie
  • 68. 68 • Inclusion of building torsion (no standardized guidelines available) • Inclusion of higher modes in PA – PA with vectors that represent the effects of multiple modes (FEMA 356) – Explicit consideration of Multiple Modes • Modal Pushover Analysis (Chopra and Goel, (2001). • Incremental Response Spectrum Analysis (Aydinoglu, 2003) • Consecutive Modal Pushover (Poursha et al., 2009) – Progressive changes in the load vector pattern applied to the structure. • Displacement Adaptive Pushover (Antoniou and Pinho, 2004) • IS:1893-2002 is yet to include the method Limitations The Pushover Analysis – from basics Presented by Rahul Leslie
  • 69. 69 References: • IS 1893 (Part 1)–2002, “Indian Standard Criteria for Earthquake Resistant Design of Structures, Part 1: General Provision and Buildings”, Bureau of Indian Standards, New Delhi. • FEMA 356 (2000) “Prestandard and Commentary for the Seismic Rehabilitation of Buildings”, Federal Emergency Management Agency, Washington, DC, USA. • ATC-40 (1996) “Seismic Analysis and Retrofit of Concrete Buildings”, vol. I, Applied Technology Council, Redwood City, CA, USA. • FEMA-440 (2005) “Improvement of Nonlinear static seismic analysis procedures”, Federal Emergency Management Agency, Washington, DC, U.S.A. • prEN 1998-1 (2003) “Eurocode 8 Part 1: Design of structures for earthquake resistance”, European Committee for Standardization, Brussels. • Jisha S. V. (2008), Mini Project Report “Pushover Analysis”, Department of Civil Engineering, T. K. M. College of Engineering, Kollam, Kerala. The Pushover Analysis – from basics Presented by Rahul Leslie
  • 70. 70 A write up on this topic can be found at … http://rahulleslie.blogspot.in/p/blog-page.html … but covers only the ATC-40 method of pushover analysis. Note The Pushover Analysis – from basics Presented by Rahul Leslie
  • 71. 71 An effort has been made to present the topic as simple as possible… …presume, at least to some extend, the aim has been fulfilled. Conclusion Thank you rahul.leslie@gmail.com