Analysis
P&ID is a Piping and
Instrumentation Diagram
To identify risk from a set of
P&ID you must have clear
understanding of three
things…
#1

Understand the
process
#2
Understand the
failures
#3

Understand the
consequence
Lines are used for showing
piping, equipment and
instrumentation
connections…
…so people can
communicate the process
sequence and the
relationship of different
equipment
Equipment and
instrumentation are
connected by lines
Here are some common
connections
Pipe




       Common Failure Modes:
       - Collapse
       - Burst/Rupture
       - Erosion
       - Corrosion
Electrical Signal




           Common Failure Modes:
           - Open connection
           - Electrical shorting
           - Electromagnetic interference
Pneumatic Signal




           Common Failure Modes:
           - Leakage of internal fluid
           - High components friction level
           - Loss of pressure
Data Signal




              Common Failure Modes:
              - Radio interference
              - Signal filtering
              - Packets Loss
              - Loss of signal
Flexible Pipe




           Common Failure Modes:
           - Compressive failure
           - Tensile failure
           - Over bending
           - Rupture
Symbols are used to
simplify drawings



              >>>
              >>>
              >>>




  From this         To this
Some equipment are
used to add or reduce
energy in the material
Blower




         Common Failure Modes:
         - Fail to operate on demand
         - Loss of pressure
Furnace




          Common Failure Modes:
          - Flame out
Pump




       Common Failure Modes:
       - Fail to operate on demand
       - Loss of pressure
       - Over pressure
Compressor




         Common Failure Modes:
         - Fail to start
         - Damage due to liquid
         - Over pressure
         - Excessive vibration
Heat exchanger




           Common Failure Modes:
           - Leakage
           - Corrosion
           - Plugged
Plate Heat Exchanger




           Common Failure Modes:
           - Leakage
           - Corrosion
           - Plugged
Aerial Fan




             Common Failure Modes:
             - Loss of air circulation
Some equipment are
used for material
storage
Floating Storage Tank




           Common Failure Modes:
           - Overflow
           - Leakage
Sphere Tank




          Common Failure Modes:
          - Overpressure
Pressurized Vessel




           Common Failure Modes:
           - Overpressure
Some equipment are
used to separate
material
Horizontal Separator




          Common Failure Modes:
          - Overpressure
Vertical Separator




          Common Failure Modes:
          - Overpressure
Fluid Contacting Column




            Common Failure Modes:
            - Overpressure
            - Corrosion
            - Plugged
Tray Column




          Common Failure Modes:
          - Overpressure
          - Contamination
Valves are used to
control the flow of
material
Manual Valve




          Common Failure Modes:
          - External leakage
          - Internal leakage
          - Inadvertent position
Control Valve




          Common Failure Modes:
          - Fail to close on demand
          - Fail to open on demand
          - Spurious operation
          - Leakage
Solenoid
Valve
   S



           Common Failure Modes:
           - Structural failure
           - Seat Leakage
           - Seal Leakage
           - Loss of actuator
Motor-operated
Valve

  M



          Common Failure Modes:
          - Motor failure
          - Fail to stroke
Butterfly Valve




            Common Failure Modes:
            - Fail to close on demand
            - Fail to open on demand
            - Spurious operation
Globe Valve




          Common Failure Modes:
          - Fail to close on demand
          - Fail to open on demand
          - Spurious operation
          - Leakage
Needle Valve




           Common Failure Modes:
           - Fail to close on demand
           - Fail to open on demand
           - Spurious operation
           - Leakage
Ball Valve




             Common Failure Modes:
             - Fail to close on demand
             - Fail to open on demand
             - Spurious operation
             - Leakage
Check valve




              Common Failure Modes:
              - Leakage
              - Stuck at open position
Some equipment are
used to relief pressure
in the process
Relief Valve




           Common Failure Modes:
           - Fail to open
Curved Gas Vent




           Common Failure Modes:
           - Plugged
Rupture Disk




           Common Failure Modes:
           - Corrosion
Control system are used
to manage the behaviour
of the process
Programmable Logic
Control




          Common Failure Modes:
          - Software error
          - Execution error
Shared display, shared
Control




            Common Failure Modes:
            - Software error
            - Execution error
Sensors are used to
measure the physical
properties of the process
and convert it into a signal
Flow Transmitter


  FT


          Common Failure Modes:
          - Spurious measurement
          - Loss of measurement
Pressure Transmitter


  PT


          Common Failure Modes:
          - Spurious measurement
          - Loss of measurement
Level Transmitter


  LT


           Common Failure Modes:
           - Spurious measurement
           - Loss of measurement
Now lets identify the risk
of this process…
D-101 Re-boiler Condensate Pot

                                                         PSV      Size ½
                                                         111      SET @ 700kPag
                                                                            To atmosphere at safe
                                                                            location
Steam
 Drawing Ref.                   D-101
                                                       LT
          3/4”          2”                             253
                                                  3”


                             HLL=2550 mm
                  LG
                  253
                             NLL=1650 mm
                             LLL=250 mm                               LC
                        2”
                                                  3”                 253


           3/4”
                                                                                        6”
                                                                      LY           LV
                                                                     253          253


                                                                                               Condensate
                                             6”              6”                   6”
                                                                                                    Drawing Ref.




                                                                     6”
Step 1: Understand the process
•   There is low pressure steam
    flowing into the vessel
•   The steam cools and forms
    condensate in the condensate pot
•   The level of the condensate liquid is
    controlled by a level control loop
•   Condensate is drained out the
    bottom of the vessel
Start                      D-101 Re-boiler Condensate Pot

                                                         PSV      Size ½
                                                         111      SET @ 700kPag
                                                                            To atmosphere at safe
                                                                            location
Steam
 Drawing Ref.                   D-101
                                                       LT
          3/4”          2”                             253
                                                  3”


                             HLL=2550 mm
                  LG
                  253
                             NLL=1650 mm
                             LLL=250 mm                               LC
                        2”
                                                  3”                 253


           3/4”
                                                                                        6”
                                                                      LY           LV
                                                                     253          253


                                                                                               Condensate
                                             6”              6”                   6”
                                                                                                    Drawing Ref.




                                                                     6”
Step 2: Identify possible
failures

The control loop can
malfunction causing the
valve LV253 to fail in the
closed position
D-101 Re-boiler Condensate Pot

                                                         PSV      Size ½
                                                         111      SET @ 700kPag
                                                                            To atmosphere at safe
                                                                            location
Steam
 Drawing Ref.                   D-101
                                                       LT
          3/4”          2”                             253
                                                  3”


                             HLL=2550 mm
                  PG
                  253
                             NLL=1650 mm
                             LLL=250 mm                               LC
                        2”
                                                  3”                 253


           3/4”
                                                                                        6”
                                                                      LY           LV
                                                                     253          253


                                                                                               Condensate
                                             6”              6”                   6”
                                                                                                    Drawing Ref.




                                                                     6”
Step 3: Assess the consequence

•   The level control valve fails in the
    closed position blocking the drain
    line
•   Hazard is high level and high
    pressure in the tank
•   Potential consequence of loss of
    containment and equipment damage
    with $$$$ losses
Now you have identified
the cause of the
overpressure hazard, can
you identify the
safeguard?
The pressure relief with
a set point of 700 kPa
will open and reduce but
not eliminate the risk of
rupture
D-101 Re-boiler Condensate Pot

                                                         PSV      Size ½
                                                         111      SET @ 700kPag
                                                                            To atmosphere at safe
                                                                            location
Steam
 Drawing Ref.                   D-101
                                                       LT
          3/4”          2”                             253
                                                  3”


                             HLL=2550 mm
                  LG
                  253
                             NLL=1650 mm
                             LLL=250 mm                               LC
                        2”
                                                  3”                 253


           3/4”
                                                                                        6”
                                                                      LY           LV
                                                                     253          253


                                                                                               Condensate
                                             6”              6”                   6”
                                                                                                    Drawing Ref.




                                                                     6”
By understanding the P&ID
you can clearly assess
risk in your operation and
make good decisions
Any Questions?
Risk. Inspired.




For more lessons go to
www.icarus-orm.com

More Related Content

What's hot

Distillation Towers (Columns) presentation on Types, governing Equations and ...
Distillation Towers (Columns) presentation on Types, governing Equations and ...Distillation Towers (Columns) presentation on Types, governing Equations and ...
Distillation Towers (Columns) presentation on Types, governing Equations and ...Hassan ElBanhawi
 
psv and pvrvdesign calculation.ppt
psv and pvrvdesign calculation.pptpsv and pvrvdesign calculation.ppt
psv and pvrvdesign calculation.pptssuser73bb74
 
PIPING & INSTRUMENTATION DIAGRAM.pdf
PIPING & INSTRUMENTATION DIAGRAM.pdfPIPING & INSTRUMENTATION DIAGRAM.pdf
PIPING & INSTRUMENTATION DIAGRAM.pdfMassinissaHamel
 
Accumulation and Over-pressure: difference between accumulation and overpressure
Accumulation and Over-pressure: difference between accumulation and overpressureAccumulation and Over-pressure: difference between accumulation and overpressure
Accumulation and Over-pressure: difference between accumulation and overpressureVarun Patel
 
Overpressure scenarios overview final
Overpressure scenarios overview finalOverpressure scenarios overview final
Overpressure scenarios overview finalRajiv Natkar
 
Pressure Reliveing Devices1
Pressure Reliveing Devices1Pressure Reliveing Devices1
Pressure Reliveing Devices1Om Pratap Singh
 
GAS SWEETENING PROCESSES
GAS SWEETENING PROCESSESGAS SWEETENING PROCESSES
GAS SWEETENING PROCESSESRisman Hatibi
 
Overpressure protection
Overpressure protectionOverpressure protection
Overpressure protectionWei Chiao Kuo
 
HTRI PRESENTATION.pdf
HTRI PRESENTATION.pdfHTRI PRESENTATION.pdf
HTRI PRESENTATION.pdfssuserbd5784
 
Design and Rating of Trayed Distillation Columns
Design and Rating  of Trayed Distillation ColumnsDesign and Rating  of Trayed Distillation Columns
Design and Rating of Trayed Distillation ColumnsGerard B. Hawkins
 
Mechanical Seals Piping Plans Api 628
Mechanical Seals Piping Plans   Api 628Mechanical Seals Piping Plans   Api 628
Mechanical Seals Piping Plans Api 628IONEL DUTU
 
Precommisioning and commissioning updated
Precommisioning and commissioning updatedPrecommisioning and commissioning updated
Precommisioning and commissioning updatedPersonal Secret
 
Control of Continuous Distillation Columns
Control of Continuous Distillation ColumnsControl of Continuous Distillation Columns
Control of Continuous Distillation ColumnsGerard B. Hawkins
 
Pre commissioning steam turbines load trial
Pre commissioning steam turbines load trialPre commissioning steam turbines load trial
Pre commissioning steam turbines load trialNagesh H
 
Code of Practice - Centrifugal Pump Operation and Maintenance
Code of Practice - Centrifugal Pump Operation and Maintenance Code of Practice - Centrifugal Pump Operation and Maintenance
Code of Practice - Centrifugal Pump Operation and Maintenance Gerard B. Hawkins
 

What's hot (20)

API STD 521
API STD 521API STD 521
API STD 521
 
Distillation Towers (Columns) presentation on Types, governing Equations and ...
Distillation Towers (Columns) presentation on Types, governing Equations and ...Distillation Towers (Columns) presentation on Types, governing Equations and ...
Distillation Towers (Columns) presentation on Types, governing Equations and ...
 
psv and pvrvdesign calculation.ppt
psv and pvrvdesign calculation.pptpsv and pvrvdesign calculation.ppt
psv and pvrvdesign calculation.ppt
 
PIPING & INSTRUMENTATION DIAGRAM.pdf
PIPING & INSTRUMENTATION DIAGRAM.pdfPIPING & INSTRUMENTATION DIAGRAM.pdf
PIPING & INSTRUMENTATION DIAGRAM.pdf
 
Accumulation and Over-pressure: difference between accumulation and overpressure
Accumulation and Over-pressure: difference between accumulation and overpressureAccumulation and Over-pressure: difference between accumulation and overpressure
Accumulation and Over-pressure: difference between accumulation and overpressure
 
psv specifications
psv specificationspsv specifications
psv specifications
 
Overpressure scenarios overview final
Overpressure scenarios overview finalOverpressure scenarios overview final
Overpressure scenarios overview final
 
Hazop Study
Hazop StudyHazop Study
Hazop Study
 
Pressure Reliveing Devices1
Pressure Reliveing Devices1Pressure Reliveing Devices1
Pressure Reliveing Devices1
 
Introduction of Fired heaters
Introduction of Fired heatersIntroduction of Fired heaters
Introduction of Fired heaters
 
GAS SWEETENING PROCESSES
GAS SWEETENING PROCESSESGAS SWEETENING PROCESSES
GAS SWEETENING PROCESSES
 
Overpressure protection
Overpressure protectionOverpressure protection
Overpressure protection
 
HTRI PRESENTATION.pdf
HTRI PRESENTATION.pdfHTRI PRESENTATION.pdf
HTRI PRESENTATION.pdf
 
Design and Rating of Trayed Distillation Columns
Design and Rating  of Trayed Distillation ColumnsDesign and Rating  of Trayed Distillation Columns
Design and Rating of Trayed Distillation Columns
 
Mechanical Seals Piping Plans Api 628
Mechanical Seals Piping Plans   Api 628Mechanical Seals Piping Plans   Api 628
Mechanical Seals Piping Plans Api 628
 
valve maintenance
valve maintenancevalve maintenance
valve maintenance
 
Precommisioning and commissioning updated
Precommisioning and commissioning updatedPrecommisioning and commissioning updated
Precommisioning and commissioning updated
 
Control of Continuous Distillation Columns
Control of Continuous Distillation ColumnsControl of Continuous Distillation Columns
Control of Continuous Distillation Columns
 
Pre commissioning steam turbines load trial
Pre commissioning steam turbines load trialPre commissioning steam turbines load trial
Pre commissioning steam turbines load trial
 
Code of Practice - Centrifugal Pump Operation and Maintenance
Code of Practice - Centrifugal Pump Operation and Maintenance Code of Practice - Centrifugal Pump Operation and Maintenance
Code of Practice - Centrifugal Pump Operation and Maintenance
 

Viewers also liked

Yokogawa Presantesation(1)
Yokogawa Presantesation(1)Yokogawa Presantesation(1)
Yokogawa Presantesation(1)Maulik kunjadiya
 
Piping and Insruementaion Diagrams
Piping and Insruementaion DiagramsPiping and Insruementaion Diagrams
Piping and Insruementaion DiagramsTejas Deshpande
 
PID Controller
PID ControllerPID Controller
PID Controllersaishah72
 
P&ID presentation - Copy
P&ID presentation - CopyP&ID presentation - Copy
P&ID presentation - Copyuzoma nwogu
 
Valve types and selection
Valve types and selectionValve types and selection
Valve types and selectionMusa Sabri
 
Pid guide
Pid guidePid guide
Pid guide丹 丹
 
Weatherford Certificates
Weatherford Certificates Weatherford Certificates
Weatherford Certificates Salah Mansour
 
Service Operator Surface Well Testing
Service Operator Surface Well TestingService Operator Surface Well Testing
Service Operator Surface Well TestingJason Situmorang
 
Pc based instrumentation and control
Pc based instrumentation and controlPc based instrumentation and control
Pc based instrumentation and controlCarlos Rubio
 
Industrial Control Systems - PID Controllers
Industrial Control Systems - PID ControllersIndustrial Control Systems - PID Controllers
Industrial Control Systems - PID ControllersBehzad Samadi
 
Pid controller by Mitesh Kumar
Pid controller by Mitesh KumarPid controller by Mitesh Kumar
Pid controller by Mitesh KumarMitesh Kumar
 
expro-welltest service partner
expro-welltest service partnerexpro-welltest service partner
expro-welltest service partneruzoma nwogu
 

Viewers also liked (20)

01 p&id - 1
01 p&id - 101 p&id - 1
01 p&id - 1
 
Yokogawa Presantesation(1)
Yokogawa Presantesation(1)Yokogawa Presantesation(1)
Yokogawa Presantesation(1)
 
Piping and Insruementaion Diagrams
Piping and Insruementaion DiagramsPiping and Insruementaion Diagrams
Piping and Insruementaion Diagrams
 
Piping & Instrument Diagram
Piping & Instrument DiagramPiping & Instrument Diagram
Piping & Instrument Diagram
 
PID Controller
PID ControllerPID Controller
PID Controller
 
P&id
P&idP&id
P&id
 
P&ID presentation - Copy
P&ID presentation - CopyP&ID presentation - Copy
P&ID presentation - Copy
 
Class 13 p & i diagram
Class 13   p & i diagramClass 13   p & i diagram
Class 13 p & i diagram
 
P & i diagram
P & i diagramP & i diagram
P & i diagram
 
Valve types and selection
Valve types and selectionValve types and selection
Valve types and selection
 
Pid guide
Pid guidePid guide
Pid guide
 
Weatherford Certificates
Weatherford Certificates Weatherford Certificates
Weatherford Certificates
 
Service Operator Surface Well Testing
Service Operator Surface Well TestingService Operator Surface Well Testing
Service Operator Surface Well Testing
 
Minggu3 pid
Minggu3 pidMinggu3 pid
Minggu3 pid
 
Pc based instrumentation and control
Pc based instrumentation and controlPc based instrumentation and control
Pc based instrumentation and control
 
Industrial Control Systems - PID Controllers
Industrial Control Systems - PID ControllersIndustrial Control Systems - PID Controllers
Industrial Control Systems - PID Controllers
 
instrumentation docments
instrumentation docmentsinstrumentation docments
instrumentation docments
 
Pid controller
Pid controllerPid controller
Pid controller
 
Pid controller by Mitesh Kumar
Pid controller by Mitesh KumarPid controller by Mitesh Kumar
Pid controller by Mitesh Kumar
 
expro-welltest service partner
expro-welltest service partnerexpro-welltest service partner
expro-welltest service partner
 

Similar to How to read a P&ID for Risk Analysis

IS MANAGED PRESSURE DRILLING (MPD) ALWAYS THE CURE?
IS MANAGED PRESSURE DRILLING (MPD) ALWAYS THE CURE?IS MANAGED PRESSURE DRILLING (MPD) ALWAYS THE CURE?
IS MANAGED PRESSURE DRILLING (MPD) ALWAYS THE CURE?iQHub
 
VALVES.pdf
VALVES.pdfVALVES.pdf
VALVES.pdfeldoctol
 
10 Ways to murder your pump.pdf
10 Ways to murder your pump.pdf10 Ways to murder your pump.pdf
10 Ways to murder your pump.pdfKetanBhore
 
Cavitation Reduction in Industrial Process Control Valves
Cavitation Reduction in Industrial Process Control ValvesCavitation Reduction in Industrial Process Control Valves
Cavitation Reduction in Industrial Process Control ValvesCTi Controltech
 
Cavitation Control in Process Control Valves
Cavitation Control in Process Control ValvesCavitation Control in Process Control Valves
Cavitation Control in Process Control ValvesAnalynk Wireless, LLC
 
Controlling Cavitation in Industrial Control Valves
Controlling Cavitation in Industrial Control ValvesControlling Cavitation in Industrial Control Valves
Controlling Cavitation in Industrial Control ValvesCTi Controltech
 
Chapter9 Hydrant Bradburn
Chapter9 Hydrant BradburnChapter9 Hydrant Bradburn
Chapter9 Hydrant Bradburnmjbradburn
 
OMNI SOLARIS ON DRY DOCK LIST ENGINE
OMNI SOLARIS ON DRY DOCK LIST ENGINEOMNI SOLARIS ON DRY DOCK LIST ENGINE
OMNI SOLARIS ON DRY DOCK LIST ENGINEMior Mohd Ashrul
 
Condenser in thermal power plants
Condenser in thermal power plantsCondenser in thermal power plants
Condenser in thermal power plantsSHIVAJI CHOUDHURY
 
Filter part list
Filter part listFilter part list
Filter part listJ2smartceo
 
Waterex softener installation manual
Waterex softener installation manualWaterex softener installation manual
Waterex softener installation manualwaterexsds
 

Similar to How to read a P&ID for Risk Analysis (20)

IS MANAGED PRESSURE DRILLING (MPD) ALWAYS THE CURE?
IS MANAGED PRESSURE DRILLING (MPD) ALWAYS THE CURE?IS MANAGED PRESSURE DRILLING (MPD) ALWAYS THE CURE?
IS MANAGED PRESSURE DRILLING (MPD) ALWAYS THE CURE?
 
What is a HAZOP?
What is a HAZOP?What is a HAZOP?
What is a HAZOP?
 
VALVES.pdf
VALVES.pdfVALVES.pdf
VALVES.pdf
 
Valves.pdf
Valves.pdfValves.pdf
Valves.pdf
 
Wen_Design.ppt
Wen_Design.pptWen_Design.ppt
Wen_Design.ppt
 
10 Ways to murder your pump.pdf
10 Ways to murder your pump.pdf10 Ways to murder your pump.pdf
10 Ways to murder your pump.pdf
 
Winterization
WinterizationWinterization
Winterization
 
Cavitation Control in Industrial Valves
Cavitation Control in Industrial ValvesCavitation Control in Industrial Valves
Cavitation Control in Industrial Valves
 
Cavitation Reduction in Industrial Process Control Valves
Cavitation Reduction in Industrial Process Control ValvesCavitation Reduction in Industrial Process Control Valves
Cavitation Reduction in Industrial Process Control Valves
 
Cavitation Control in Process Control Valves
Cavitation Control in Process Control ValvesCavitation Control in Process Control Valves
Cavitation Control in Process Control Valves
 
Controlling Cavitation in Industrial Control Valves
Controlling Cavitation in Industrial Control ValvesControlling Cavitation in Industrial Control Valves
Controlling Cavitation in Industrial Control Valves
 
Valves
Valves Valves
Valves
 
Transformer
TransformerTransformer
Transformer
 
Chapter9 Hydrant Bradburn
Chapter9 Hydrant BradburnChapter9 Hydrant Bradburn
Chapter9 Hydrant Bradburn
 
OMNI SOLARIS ON DRY DOCK LIST ENGINE
OMNI SOLARIS ON DRY DOCK LIST ENGINEOMNI SOLARIS ON DRY DOCK LIST ENGINE
OMNI SOLARIS ON DRY DOCK LIST ENGINE
 
Condenser in thermal power plants
Condenser in thermal power plantsCondenser in thermal power plants
Condenser in thermal power plants
 
Filter part list
Filter part listFilter part list
Filter part list
 
What is a LOPA?
What is a LOPA?What is a LOPA?
What is a LOPA?
 
Waterex softener installation manual
Waterex softener installation manualWaterex softener installation manual
Waterex softener installation manual
 
Welding of pipelines
Welding of pipelinesWelding of pipelines
Welding of pipelines
 

Recently uploaded

Cracking the Cultural Competence Code.pptx
Cracking the Cultural Competence Code.pptxCracking the Cultural Competence Code.pptx
Cracking the Cultural Competence Code.pptxWorkforce Group
 
Phases of Negotiation .pptx
 Phases of Negotiation .pptx Phases of Negotiation .pptx
Phases of Negotiation .pptxnandhinijagan9867
 
Call Girls Zirakpur👧 Book Now📱7837612180 📞👉Call Girl Service In Zirakpur No A...
Call Girls Zirakpur👧 Book Now📱7837612180 📞👉Call Girl Service In Zirakpur No A...Call Girls Zirakpur👧 Book Now📱7837612180 📞👉Call Girl Service In Zirakpur No A...
Call Girls Zirakpur👧 Book Now📱7837612180 📞👉Call Girl Service In Zirakpur No A...Sheetaleventcompany
 
Famous Olympic Siblings from the 21st Century
Famous Olympic Siblings from the 21st CenturyFamous Olympic Siblings from the 21st Century
Famous Olympic Siblings from the 21st Centuryrwgiffor
 
BAGALUR CALL GIRL IN 98274*61493 ❤CALL GIRLS IN ESCORT SERVICE❤CALL GIRL
BAGALUR CALL GIRL IN 98274*61493 ❤CALL GIRLS IN ESCORT SERVICE❤CALL GIRLBAGALUR CALL GIRL IN 98274*61493 ❤CALL GIRLS IN ESCORT SERVICE❤CALL GIRL
BAGALUR CALL GIRL IN 98274*61493 ❤CALL GIRLS IN ESCORT SERVICE❤CALL GIRLkapoorjyoti4444
 
Falcon Invoice Discounting: The best investment platform in india for investors
Falcon Invoice Discounting: The best investment platform in india for investorsFalcon Invoice Discounting: The best investment platform in india for investors
Falcon Invoice Discounting: The best investment platform in india for investorsFalcon Invoice Discounting
 
Malegaon Call Girls Service ☎ ️82500–77686 ☎️ Enjoy 24/7 Escort Service
Malegaon Call Girls Service ☎ ️82500–77686 ☎️ Enjoy 24/7 Escort ServiceMalegaon Call Girls Service ☎ ️82500–77686 ☎️ Enjoy 24/7 Escort Service
Malegaon Call Girls Service ☎ ️82500–77686 ☎️ Enjoy 24/7 Escort ServiceDamini Dixit
 
Call Now ☎️🔝 9332606886🔝 Call Girls ❤ Service In Bhilwara Female Escorts Serv...
Call Now ☎️🔝 9332606886🔝 Call Girls ❤ Service In Bhilwara Female Escorts Serv...Call Now ☎️🔝 9332606886🔝 Call Girls ❤ Service In Bhilwara Female Escorts Serv...
Call Now ☎️🔝 9332606886🔝 Call Girls ❤ Service In Bhilwara Female Escorts Serv...Anamikakaur10
 
Falcon Invoice Discounting: Empowering Your Business Growth
Falcon Invoice Discounting: Empowering Your Business GrowthFalcon Invoice Discounting: Empowering Your Business Growth
Falcon Invoice Discounting: Empowering Your Business GrowthFalcon investment
 
Uneak White's Personal Brand Exploration Presentation
Uneak White's Personal Brand Exploration PresentationUneak White's Personal Brand Exploration Presentation
Uneak White's Personal Brand Exploration Presentationuneakwhite
 
👉Chandigarh Call Girls 👉9878799926👉Just Call👉Chandigarh Call Girl In Chandiga...
👉Chandigarh Call Girls 👉9878799926👉Just Call👉Chandigarh Call Girl In Chandiga...👉Chandigarh Call Girls 👉9878799926👉Just Call👉Chandigarh Call Girl In Chandiga...
👉Chandigarh Call Girls 👉9878799926👉Just Call👉Chandigarh Call Girl In Chandiga...rajveerescorts2022
 
SEO Case Study: How I Increased SEO Traffic & Ranking by 50-60% in 6 Months
SEO Case Study: How I Increased SEO Traffic & Ranking by 50-60%  in 6 MonthsSEO Case Study: How I Increased SEO Traffic & Ranking by 50-60%  in 6 Months
SEO Case Study: How I Increased SEO Traffic & Ranking by 50-60% in 6 MonthsIndeedSEO
 
Call Girls Ludhiana Just Call 98765-12871 Top Class Call Girl Service Available
Call Girls Ludhiana Just Call 98765-12871 Top Class Call Girl Service AvailableCall Girls Ludhiana Just Call 98765-12871 Top Class Call Girl Service Available
Call Girls Ludhiana Just Call 98765-12871 Top Class Call Girl Service AvailableSeo
 
Whitefield CALL GIRL IN 98274*61493 ❤CALL GIRLS IN ESCORT SERVICE❤CALL GIRL
Whitefield CALL GIRL IN 98274*61493 ❤CALL GIRLS IN ESCORT SERVICE❤CALL GIRLWhitefield CALL GIRL IN 98274*61493 ❤CALL GIRLS IN ESCORT SERVICE❤CALL GIRL
Whitefield CALL GIRL IN 98274*61493 ❤CALL GIRLS IN ESCORT SERVICE❤CALL GIRLkapoorjyoti4444
 
FULL ENJOY Call Girls In Majnu Ka Tilla, Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Majnu Ka Tilla, Delhi Contact Us 8377877756FULL ENJOY Call Girls In Majnu Ka Tilla, Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Majnu Ka Tilla, Delhi Contact Us 8377877756dollysharma2066
 
Value Proposition canvas- Customer needs and pains
Value Proposition canvas- Customer needs and painsValue Proposition canvas- Customer needs and pains
Value Proposition canvas- Customer needs and painsP&CO
 
Business Model Canvas (BMC)- A new venture concept
Business Model Canvas (BMC)-  A new venture conceptBusiness Model Canvas (BMC)-  A new venture concept
Business Model Canvas (BMC)- A new venture conceptP&CO
 
Call Girls in Delhi, Escort Service Available 24x7 in Delhi 959961-/-3876
Call Girls in Delhi, Escort Service Available 24x7 in Delhi 959961-/-3876Call Girls in Delhi, Escort Service Available 24x7 in Delhi 959961-/-3876
Call Girls in Delhi, Escort Service Available 24x7 in Delhi 959961-/-3876dlhescort
 

Recently uploaded (20)

Cracking the Cultural Competence Code.pptx
Cracking the Cultural Competence Code.pptxCracking the Cultural Competence Code.pptx
Cracking the Cultural Competence Code.pptx
 
Phases of Negotiation .pptx
 Phases of Negotiation .pptx Phases of Negotiation .pptx
Phases of Negotiation .pptx
 
Call Girls Zirakpur👧 Book Now📱7837612180 📞👉Call Girl Service In Zirakpur No A...
Call Girls Zirakpur👧 Book Now📱7837612180 📞👉Call Girl Service In Zirakpur No A...Call Girls Zirakpur👧 Book Now📱7837612180 📞👉Call Girl Service In Zirakpur No A...
Call Girls Zirakpur👧 Book Now📱7837612180 📞👉Call Girl Service In Zirakpur No A...
 
Famous Olympic Siblings from the 21st Century
Famous Olympic Siblings from the 21st CenturyFamous Olympic Siblings from the 21st Century
Famous Olympic Siblings from the 21st Century
 
BAGALUR CALL GIRL IN 98274*61493 ❤CALL GIRLS IN ESCORT SERVICE❤CALL GIRL
BAGALUR CALL GIRL IN 98274*61493 ❤CALL GIRLS IN ESCORT SERVICE❤CALL GIRLBAGALUR CALL GIRL IN 98274*61493 ❤CALL GIRLS IN ESCORT SERVICE❤CALL GIRL
BAGALUR CALL GIRL IN 98274*61493 ❤CALL GIRLS IN ESCORT SERVICE❤CALL GIRL
 
Falcon Invoice Discounting: The best investment platform in india for investors
Falcon Invoice Discounting: The best investment platform in india for investorsFalcon Invoice Discounting: The best investment platform in india for investors
Falcon Invoice Discounting: The best investment platform in india for investors
 
Malegaon Call Girls Service ☎ ️82500–77686 ☎️ Enjoy 24/7 Escort Service
Malegaon Call Girls Service ☎ ️82500–77686 ☎️ Enjoy 24/7 Escort ServiceMalegaon Call Girls Service ☎ ️82500–77686 ☎️ Enjoy 24/7 Escort Service
Malegaon Call Girls Service ☎ ️82500–77686 ☎️ Enjoy 24/7 Escort Service
 
Call Now ☎️🔝 9332606886🔝 Call Girls ❤ Service In Bhilwara Female Escorts Serv...
Call Now ☎️🔝 9332606886🔝 Call Girls ❤ Service In Bhilwara Female Escorts Serv...Call Now ☎️🔝 9332606886🔝 Call Girls ❤ Service In Bhilwara Female Escorts Serv...
Call Now ☎️🔝 9332606886🔝 Call Girls ❤ Service In Bhilwara Female Escorts Serv...
 
unwanted pregnancy Kit [+918133066128] Abortion Pills IN Dubai UAE Abudhabi
unwanted pregnancy Kit [+918133066128] Abortion Pills IN Dubai UAE Abudhabiunwanted pregnancy Kit [+918133066128] Abortion Pills IN Dubai UAE Abudhabi
unwanted pregnancy Kit [+918133066128] Abortion Pills IN Dubai UAE Abudhabi
 
Falcon Invoice Discounting: Empowering Your Business Growth
Falcon Invoice Discounting: Empowering Your Business GrowthFalcon Invoice Discounting: Empowering Your Business Growth
Falcon Invoice Discounting: Empowering Your Business Growth
 
Uneak White's Personal Brand Exploration Presentation
Uneak White's Personal Brand Exploration PresentationUneak White's Personal Brand Exploration Presentation
Uneak White's Personal Brand Exploration Presentation
 
👉Chandigarh Call Girls 👉9878799926👉Just Call👉Chandigarh Call Girl In Chandiga...
👉Chandigarh Call Girls 👉9878799926👉Just Call👉Chandigarh Call Girl In Chandiga...👉Chandigarh Call Girls 👉9878799926👉Just Call👉Chandigarh Call Girl In Chandiga...
👉Chandigarh Call Girls 👉9878799926👉Just Call👉Chandigarh Call Girl In Chandiga...
 
SEO Case Study: How I Increased SEO Traffic & Ranking by 50-60% in 6 Months
SEO Case Study: How I Increased SEO Traffic & Ranking by 50-60%  in 6 MonthsSEO Case Study: How I Increased SEO Traffic & Ranking by 50-60%  in 6 Months
SEO Case Study: How I Increased SEO Traffic & Ranking by 50-60% in 6 Months
 
Call Girls Ludhiana Just Call 98765-12871 Top Class Call Girl Service Available
Call Girls Ludhiana Just Call 98765-12871 Top Class Call Girl Service AvailableCall Girls Ludhiana Just Call 98765-12871 Top Class Call Girl Service Available
Call Girls Ludhiana Just Call 98765-12871 Top Class Call Girl Service Available
 
Whitefield CALL GIRL IN 98274*61493 ❤CALL GIRLS IN ESCORT SERVICE❤CALL GIRL
Whitefield CALL GIRL IN 98274*61493 ❤CALL GIRLS IN ESCORT SERVICE❤CALL GIRLWhitefield CALL GIRL IN 98274*61493 ❤CALL GIRLS IN ESCORT SERVICE❤CALL GIRL
Whitefield CALL GIRL IN 98274*61493 ❤CALL GIRLS IN ESCORT SERVICE❤CALL GIRL
 
FULL ENJOY Call Girls In Majnu Ka Tilla, Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Majnu Ka Tilla, Delhi Contact Us 8377877756FULL ENJOY Call Girls In Majnu Ka Tilla, Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Majnu Ka Tilla, Delhi Contact Us 8377877756
 
Value Proposition canvas- Customer needs and pains
Value Proposition canvas- Customer needs and painsValue Proposition canvas- Customer needs and pains
Value Proposition canvas- Customer needs and pains
 
Falcon Invoice Discounting platform in india
Falcon Invoice Discounting platform in indiaFalcon Invoice Discounting platform in india
Falcon Invoice Discounting platform in india
 
Business Model Canvas (BMC)- A new venture concept
Business Model Canvas (BMC)-  A new venture conceptBusiness Model Canvas (BMC)-  A new venture concept
Business Model Canvas (BMC)- A new venture concept
 
Call Girls in Delhi, Escort Service Available 24x7 in Delhi 959961-/-3876
Call Girls in Delhi, Escort Service Available 24x7 in Delhi 959961-/-3876Call Girls in Delhi, Escort Service Available 24x7 in Delhi 959961-/-3876
Call Girls in Delhi, Escort Service Available 24x7 in Delhi 959961-/-3876
 

How to read a P&ID for Risk Analysis

  • 1. How to Read a P&ID For Risk Analysis
  • 2. P&ID is a Piping and Instrumentation Diagram
  • 3. To identify risk from a set of P&ID you must have clear understanding of three things…
  • 7. Lines are used for showing piping, equipment and instrumentation connections…
  • 8. …so people can communicate the process sequence and the relationship of different equipment
  • 9. Equipment and instrumentation are connected by lines Here are some common connections
  • 10. Pipe Common Failure Modes: - Collapse - Burst/Rupture - Erosion - Corrosion
  • 11. Electrical Signal Common Failure Modes: - Open connection - Electrical shorting - Electromagnetic interference
  • 12. Pneumatic Signal Common Failure Modes: - Leakage of internal fluid - High components friction level - Loss of pressure
  • 13. Data Signal Common Failure Modes: - Radio interference - Signal filtering - Packets Loss - Loss of signal
  • 14. Flexible Pipe Common Failure Modes: - Compressive failure - Tensile failure - Over bending - Rupture
  • 15. Symbols are used to simplify drawings >>> >>> >>> From this To this
  • 16. Some equipment are used to add or reduce energy in the material
  • 17. Blower Common Failure Modes: - Fail to operate on demand - Loss of pressure
  • 18. Furnace Common Failure Modes: - Flame out
  • 19. Pump Common Failure Modes: - Fail to operate on demand - Loss of pressure - Over pressure
  • 20. Compressor Common Failure Modes: - Fail to start - Damage due to liquid - Over pressure - Excessive vibration
  • 21. Heat exchanger Common Failure Modes: - Leakage - Corrosion - Plugged
  • 22. Plate Heat Exchanger Common Failure Modes: - Leakage - Corrosion - Plugged
  • 23. Aerial Fan Common Failure Modes: - Loss of air circulation
  • 24. Some equipment are used for material storage
  • 25. Floating Storage Tank Common Failure Modes: - Overflow - Leakage
  • 26. Sphere Tank Common Failure Modes: - Overpressure
  • 27. Pressurized Vessel Common Failure Modes: - Overpressure
  • 28. Some equipment are used to separate material
  • 29. Horizontal Separator Common Failure Modes: - Overpressure
  • 30. Vertical Separator Common Failure Modes: - Overpressure
  • 31. Fluid Contacting Column Common Failure Modes: - Overpressure - Corrosion - Plugged
  • 32. Tray Column Common Failure Modes: - Overpressure - Contamination
  • 33. Valves are used to control the flow of material
  • 34. Manual Valve Common Failure Modes: - External leakage - Internal leakage - Inadvertent position
  • 35. Control Valve Common Failure Modes: - Fail to close on demand - Fail to open on demand - Spurious operation - Leakage
  • 36. Solenoid Valve S Common Failure Modes: - Structural failure - Seat Leakage - Seal Leakage - Loss of actuator
  • 37. Motor-operated Valve M Common Failure Modes: - Motor failure - Fail to stroke
  • 38. Butterfly Valve Common Failure Modes: - Fail to close on demand - Fail to open on demand - Spurious operation
  • 39. Globe Valve Common Failure Modes: - Fail to close on demand - Fail to open on demand - Spurious operation - Leakage
  • 40. Needle Valve Common Failure Modes: - Fail to close on demand - Fail to open on demand - Spurious operation - Leakage
  • 41. Ball Valve Common Failure Modes: - Fail to close on demand - Fail to open on demand - Spurious operation - Leakage
  • 42. Check valve Common Failure Modes: - Leakage - Stuck at open position
  • 43. Some equipment are used to relief pressure in the process
  • 44. Relief Valve Common Failure Modes: - Fail to open
  • 45. Curved Gas Vent Common Failure Modes: - Plugged
  • 46. Rupture Disk Common Failure Modes: - Corrosion
  • 47. Control system are used to manage the behaviour of the process
  • 48. Programmable Logic Control Common Failure Modes: - Software error - Execution error
  • 49. Shared display, shared Control Common Failure Modes: - Software error - Execution error
  • 50. Sensors are used to measure the physical properties of the process and convert it into a signal
  • 51. Flow Transmitter FT Common Failure Modes: - Spurious measurement - Loss of measurement
  • 52. Pressure Transmitter PT Common Failure Modes: - Spurious measurement - Loss of measurement
  • 53. Level Transmitter LT Common Failure Modes: - Spurious measurement - Loss of measurement
  • 54. Now lets identify the risk of this process…
  • 55. D-101 Re-boiler Condensate Pot PSV Size ½ 111 SET @ 700kPag To atmosphere at safe location Steam Drawing Ref. D-101 LT 3/4” 2” 253 3” HLL=2550 mm LG 253 NLL=1650 mm LLL=250 mm LC 2” 3” 253 3/4” 6” LY LV 253 253 Condensate 6” 6” 6” Drawing Ref. 6”
  • 56. Step 1: Understand the process • There is low pressure steam flowing into the vessel • The steam cools and forms condensate in the condensate pot • The level of the condensate liquid is controlled by a level control loop • Condensate is drained out the bottom of the vessel
  • 57. Start D-101 Re-boiler Condensate Pot PSV Size ½ 111 SET @ 700kPag To atmosphere at safe location Steam Drawing Ref. D-101 LT 3/4” 2” 253 3” HLL=2550 mm LG 253 NLL=1650 mm LLL=250 mm LC 2” 3” 253 3/4” 6” LY LV 253 253 Condensate 6” 6” 6” Drawing Ref. 6”
  • 58. Step 2: Identify possible failures The control loop can malfunction causing the valve LV253 to fail in the closed position
  • 59. D-101 Re-boiler Condensate Pot PSV Size ½ 111 SET @ 700kPag To atmosphere at safe location Steam Drawing Ref. D-101 LT 3/4” 2” 253 3” HLL=2550 mm PG 253 NLL=1650 mm LLL=250 mm LC 2” 3” 253 3/4” 6” LY LV 253 253 Condensate 6” 6” 6” Drawing Ref. 6”
  • 60. Step 3: Assess the consequence • The level control valve fails in the closed position blocking the drain line • Hazard is high level and high pressure in the tank • Potential consequence of loss of containment and equipment damage with $$$$ losses
  • 61. Now you have identified the cause of the overpressure hazard, can you identify the safeguard?
  • 62. The pressure relief with a set point of 700 kPa will open and reduce but not eliminate the risk of rupture
  • 63. D-101 Re-boiler Condensate Pot PSV Size ½ 111 SET @ 700kPag To atmosphere at safe location Steam Drawing Ref. D-101 LT 3/4” 2” 253 3” HLL=2550 mm LG 253 NLL=1650 mm LLL=250 mm LC 2” 3” 253 3/4” 6” LY LV 253 253 Condensate 6” 6” 6” Drawing Ref. 6”
  • 64. By understanding the P&ID you can clearly assess risk in your operation and make good decisions
  • 66. Risk. Inspired. For more lessons go to www.icarus-orm.com