3 generators with inbuilt resilience, built to tier 3 design guaranteeing 100% power availability.
A external vents/grilles - utilising fresh air rather than electricity, in colder months sucking in ambient air from outside
the data centre via the window louvers rather than heating with energy hungry chiller units all year round.
generatiOn data centre. B
power provided from the national grid, UpS and generators giving n+1 backup generation with 2 feeds to every rack.
lV panel – controlling the incoming power supplies, designed to be maintained without disrupting power.
gas cylinder store – the fire detection/suppression system delivers gas directly to affected areas if required.
HellO reading Schneider cctV door card access , Single person mantrap.
24hr manned security.
Our new next generation facility in reading is the blueprint for the future of “energy efficient” C Screens showing internal and external cctV shots, monitored both locally and at the intechnology head office.
technology and equipment. Built to tier 3 standards and with a focus on innovative power Swipe access control.
usage, cooling, monitoring and maintenance, the data centre is designed to provide internal and external cameras.
reliable, secure and affordable colocation outside of central london and the M25 ring.
racks are contained within a rittal cold aisle containment pod which utilises fresh air cooling.
each pod is monitored by cctV, motion detectors and fire/heat detectors.
D each rack is secured by combination key locks.
Highly sensitive clymac VeSda fire detection system with detector heads above the racks , underfloor,
in the aisles and perimeter smoke and heat detection.
this set-up is leading edge cooling and energy management technologies with Weatherite air handling units monitoring and
gOUndFlOOr replicated on maintaining a constant temperature between 24-26 degrees.
Visitor centre the first floor. pressure release valves - if gas or fire detected all vents automatically close and cooling fans go in to recirculation mode.
B Building management system (BMS), humidity, temperature & power usage, continually monitored locally & at head office.
A
gas cylinders
C
generators
D
ment
24 / 7 monitoring cold aisle contain
Secure reception s
data centre sensor
3. N DR
WORTO
READING
DATA B3033
CENTRE
WOR
TON
WO
RT
DR
A33
AY
ON
IAL W
How to find us:
IMPER
DR
Exit the M4 at Junction 11.
AY
Take the A33 towards Reading.
W
AL
RI
PE
IM
3 3
B30
Follow the A33 for a quarter of a mile, turning
A33 right at the roundabout signposted Worton
Grange Business Park onto Imperial Way.
Follow Imperial Way and take the 1st left onto
Worton Drive.
M4
A33
The InTechnology data centre is approximately
B3270 half a mile along the road, on the right,
opposite Static Control Components Ltd.
M4 SATNAV ref:
A33
RG2 0TG
InTechnology Head Office InTechnology Reading challenge@intechnology.com
Central House Commensus House www.intechnology.com
Beckwith Knowle 3-5 Worton Drive
Harrogate Reading
HG3 1UG RG2 0TG
Tel: +44 (0)1423 850 000 Tel: +44 (0)870 777 7778
Fax: +44 (0)1423 850 001 Fax: +44 (0)870 777 7779
Certificate No. FS 578568 Certificate No. IS 578569