Heaters

Jiandong Wu
Jiandong Wuself employed en 吴建东

heaters & heating www.kirsting.com

++ Wrestt Group Co.,Ltd. +Rm 302,Hongya Jingyuan,Wuniu,Wenzhou China 325603 + sales@wrestt.com + www.kirsting.com ++ ++
These heaters are used in enclosures where damage from condensation must be prevented, or
where the temperature may not fall below a minimum value. The aluminium profile heater body
design has a chimney effect and distributes the heat evenly. The pressure clamp connectors
save time and simplify installation.
Pressure clamp connectors
Dynamic heating up
Wide voltage range
Temperature limiting
Energy saving
Clip fixing
Quick installation
Heating
Semiconductor Heater HG 140 Series 15W to 150W
Technical Data
Operating voltage 120-250V AC/DC*
Heating element PTC resistor, self regulating and temperature limiting
Heater body extruded aluminium profile, anodised
Connection 3 pressure clamps for stranded wire 0.5-1.5mm² (with wire
end ferrule) and rigid wire 0.5-2.5mm²
Connection casing plastic according to UL94 V-0, black
Mounting clip for 35mm DIN rail, EN 50022
Fitting position vertical
Operating/Storage temperature -45 to +70°C (-49 to +158°F)
Protection type / Protection class IP20 / I (earthed)
Approvals VDE, UL File No. E150057
Accessories screw fixing, Art. No. 09024.0-00 (1 packing unit = 2 pieces)
*Operating with voltages below 140V AC/DC reduces heating performance by approx. 10%.
Art. No. Heating capacity* Inrush current max. Length (L) Weight (approx.)
14000.0-00 15W 1.5A 65mm 0.30kg
14001.0-00 30W 3.0A 65mm 0.30kg
14003.0-00 45W 3.5A 65mm 0.30kg
14005.0-00 60W 2.5A 140mm 0.40kg
14006.0-00 75W 4.0A 140mm 0.50kg
14007.0-00 100W 4.5A 140mm 0.50kg
14008.0-00 150W 9.0A 220mm 0.70kg
*at 20°C (68°F) ambient temperature
C
The heaters are used in enclosures where condensation is to be prevented or the temperature
may not fall below a minimum value. In this way corrosion is avoided and an even temperature
is ensured.
Technical Data
Dynamic heating up
Energy saving
Wide voltage range
Temperature limiting
Clip fixing
Heating
Small semiconductor Heater HGK 047 Series 10W to 30W
L
N
Example of connection
Heater HGK 047KTO 011
(contact breaker, normally closed)
50 25
21003L
Clip for
35mm DIN rail
Art. No. Operating voltage
Heating
capacity1)
Inrush current
max.
Length (L)
Weight
(approx.)
Connection Approvals
04700.0-00 120-250V AC/DC2)
10W 1.0A 50mm 0.10kg 3 x 0.5mm² x 300mm sheathed cable (silicone) VDE
04701.0-00 120-250V AC/DC2)
20W 2.5A 60mm 0.20kg 3 x 0.5mm² x 300mm sheathed cable (silicone) VDE
04702.0-00 120-250V AC/DC2)
30W 3.0A 70mm 0.20kg 3 x 0.5mm² x 300mm sheathed cable (silicone) VDE
04700.9-00 110-120V AC/DC 10W 1.0A 50mm 0.10kg 3 x AWG 20 x 300mm sheathed cable UL File No. E150057
04701.9-00 110-120V AC/DC 20W 1.5A 60mm 0.20kg 3 x AWG 20 x 300mm sheathed cable UL File No. E150057
04702.9-00 110-120V AC/DC 30W 1.5A 70mm 0.20kg 3 x AWG 20 x 300mm sheathed cable UL File No. E150057
1) at 20°C (68°F) ambient temperature 2) Operating with voltages below 140V AC/DC reduces heating performance by approx. 10%.
Heating element PTC resistor, self regulating and temperature limiting
Heater body extruded aluminium profile, anodised
Mounting clip for 35mm DIN rail, EN 50022
Fitting position vertical
Operating/Storage temperature -45 to +70°C (-49 to +158°F)
Protection type / Protection class IP54 / I (earthed)
Accessories screw fixing, Art. No. 09024.0-00 (1 packing unit = 2 pieces)
C
++ Wrestt Group Co.,Ltd. +Rm 302,Hongya Jingyuan,Wuniu,Wenzhou China 325603 + sales@wrestt.com + www.kirsting.com ++ ++
Small heaters designed to prevent condensation and to ensure a minimum operating
temperature in small enclosures.
Technical Data
Temperature limiting
Wide voltage range
Dynamic heating up
Energy saving
Compact
Heating
Art. No. Heating capacity* Inrush current max. Surface temperature (approx.) Connection Weight (approx.)
01622.0-00 5W 2.0A 165°C 2 x AWG 22 sheathed cable (silicone) 20g
01623.0-00 9W 2.5A 175°C 2 x AWG 22 sheathed cable (silicone) 20g
*at 20°C (68°F) ambient temperature
Connection 2 x AWG 22 sheathed cable (silicone)
L
N
Example of connection
Heater RCE 016KTO 011
(contact breaker, normally closed)
Mounting clips Art. No. 09008.0-01 (1 packing unit = 2 pieces)
Small semiconductor Heater RCE 016 Series 5W, 9W
Operating voltage 120-250V AC/DC*
Heating element PTC resistor, self regulating and temperature limiting
Heater body aluminium
Mounting see Accessories
Fitting position variable
Operating/Storage temperature -45 to +70°C (-49 to +158°F)
Dimensions length 45mm, Ø 10mm
Protection type / Protection class IP32 / II (double insulated)
Approvals VDE, UL File No. E150057
Accessories mounting clips (see illustration)
Note other voltages on request
*Operating with voltages below 140V AC/DC reduces heating performance by approx. 10%.
C
++ Wrestt Group Co.,Ltd. +Rm 302,Hongya Jingyuan,Wuniu,Wenzhou China 325603 + sales@wrestt.com + www.kirsting.com ++ ++
These small heaters are designed to prevent condensation and to ensure a minimum operating
temperature in small enclosures.
Temperature limiting
Wide voltage range
Dynamic heating up
Energy saving
Compact
Heating
Small semiconductor Heater RC 016 Series 8W, 10W, 13W
Technical Data
Operating voltage 120-250V AC/DC*
Heating element PTC resistor, self regulating and temperature limiting
Heater body aluminium, anodised
Mounting screw fixing
Fitting position variable
Operating/Storage temperature -45 to +70°C (-49 to +158°F)
Protection type / Protection class IP32 / II (double insulated)
Approvals VDE, UL File No. E150057
Note other voltages on request
*Operating with voltages below 140V AC/DC reduces heating performance by approx. 10%.
Art. No. Heating capacity* Inrush current max. Surface temperature (approx.) Connection Weight (approx.)
01602.0-00 8W 2.0A 150°C 2 x AWG 18 stranded wire 20g
01609.0-00 10W 2.5A 155°C 2 x AWG 22 sheathed cable (silicone) 30g
01610.0-00 13W 3.0A 170°C 2 x AWG 22 sheathed cable (silicone) 40g
*at 20°C (68°F) ambient temperature
Art. No. 01602.0-00: Connection 2 x AWG 18 stranded wire
Art. No. 01609.0-00: Connection 2 x AWG 22 sheathed cable (silicone)
Art. No. 01610.0-00: Connection 2 x AWG 22 sheathed cable (silicone)
L
N
Example of connection
Heater RC 016
KTO 011
(contact breaker, normally closed)
C
++ Wrestt Group Co.,Ltd. +Rm 302,Hongya Jingyuan,Wuniu,Wenzhou China 325603 + sales@wrestt.com + www.kirsting.com ++ ++
++ Wrestt Group Co.,Ltd. +Rm 302,Hongya Jingyuan,Wuniu,Wenzhou China 325603 + sales@wrestt.com + www.kirsting.com ++ ++
Heating
The heaters are used in enclosures where condensation is to be prevented or the temperature
may not fall below a minimum value. In this way corrosion is avoided and an even temperature
is ensured. The heaters are designed for permanent operation.
Technical Data
Low surface temperature
Double insulated (plastic housing)
Wide voltage range
Temperature limiting
Dynamic heating up
Clip fixing
Touch-Safe Small Heater CSK 060 Series 10W, 20W
(Semiconductor)
Example of connection
Heater CSK 060
Thermostat FTO 011
(contact breakter, normally closed)
* at 20°C (68°F) ambient temperature
Operating voltage 120 - 240V AC/DC* (min. 110V, max. 265V)
Heating element PTC resistor - temperature limiting
Surface temperature < 85°C (185°F) (according to VDE 0100),
except upper protective grille
Connection 2-pole terminal 2.5mm², torque 0.8Nm max.
Casing plastic according to UL94 V-0, black
Dimensions 98 x 38 x 75mm
Mounting clip for 35mm DIN rail, EN 50022
Fitting position vertical
Operating/ Storage temperature -45°C to +70°C (-49°F to +158°F)
Protection type / Protection class IP20 / II (double insulated)
Approvals VDE + UL File No. E150057 (according to UL499
in combination with UL508A)
Note other voltages on request
*Operating with voltages below 140V AC/DC reduces heating performance by approx. 10%.
Art. No. Heating capacity* Inrush current max. Weight (approx.)
06040.0-00 10W 1.0A 0.20kg
06030.0-00 20W 2.5A 0.30kg
Heater
50
0
200
150
100
Heizleistung(W)
-40 -20 0
8 P J HE X Q J V WHP S HUD WX U e &
Leistungs-Umgebungstemperatur-Diagramm
CS 160
20 40
Art. Nr. 16000.0-0
Art. Nr. 16010.0-0
Art. Nr. 16020.0-0
178
160
147
132
119122
110
102
93
85
66
61
55
50
44
Low surface temperature
Quick mounting due to clip fixing
Double insulated (plastic)
Wide voltage range
Small size
Technical Data
Operating voltage 120-240V AC/DC* (min. 110V, max. 265V)
Heating capacity see table
Heating element PTC resistor - temperature limiting
Surface temperature < 80°C (176°F), except upper protective grille
Connection 4-pole terminal 2,5mm², torque 0.8Nm max.
Casing plastic according to UL94 V-0, black
Mounting clip for 35mm DIN rail, EN 50022
Fitting position vertical
Operating / Storage temperature -45 to +70°C (-49 to +158°F)
Protection type / Protection class IP20 / II (double insulated)
Approvals VDE + UL File No. E150057 (according to UL499
in combination with UL508A)
Note other voltages on request
*Operating with voltages below 140V AC/DC reduces heating performance by approx. 10%.
1)ambient temperature - see Heating capacity / Ambient temperature diagram; 2)measured 50mm above protective grille;
Heating capacity / Ambient temperature diagram CS 060
Heatingcapacity(W)
Temperature (°C)
150W
100W
50W
Art. No. Heating capacity1) Inrush current max. Air outlet temperature2) Dimensions Weight (approx.)
06000.0-00 50W 2.5A +86°C (186.8°F) 110 x 60 x 90mm 0.30kg
06010.0-00 100W 4.5A +120°C (248°F) 110 x 60 x 90mm 0.30kg
06020.0-00 150W 8A +145°C (293°F) 150 x 60 x 90mm 0.50kg
Examples of connection
Heater CS 060
Thermostat
FTO 011
Heater CS 060
AC
AC
Heater CS 060
Thermostat
FTO 011
Touch-safe heater for the use in enclosures with electrical/electronical components. The design
of the heater supports the natural convection which results in a high air-current of warm air. The
surface temperatures on the accessible side surfaces of the housing are kept down as a result
of the heater design. Our complete range of thermostats and hygrostats can directly
be connected to the heater CS 060. This heater is also available in a version with plug-in
thermostat requiring no additional wiring (CSF 060). Both versions are designed for permanent
operation.
Touch-Safe Heater CS 060 Series 50W to 150W
(semiconductor)
++ Wrestt Group Co.,Ltd. +Rm 302,Hongya Jingyuan,Wuniu,Wenzhou China 325603 + sales@wrestt.com + www.kirsting.com ++ ++
++ Wrestt Group Co.,Ltd. +Rm 302,Hongya Jingyuan,Wuniu,Wenzhou China 325603 + sales@wrestt.com + www.kirsting.com ++ ++
Heating
50
0
200
150
100
Heizleistung(W)
-40 -20 0
8 P J HE X Q J V WHP S HUD WX U e &
Leistungs-Umgebungstemperatur-Diagramm
CS 160
20 40
Art. Nr. 16000.0-0
Art. Nr. 16010.0-0
Art. Nr. 16020.0-0
178
160
147
132
119122
110
102
93
85
66
61
55
50
44
Low surface temperature
Integrated thermostat
Quick mounting due to clip fixing
Double insulated (plastic)
Wide voltage range
Small size
Technical Data
Operating voltage 120-240VAC* (min. 110V, max. 265V)
Heating capacity see table
Heating element PTC resistor - temperature limiting
Surface temperature < 80°C (176°F), except upper protective grille
Connection 4-pole terminal 2,5mm², torque 0.8Nm max.
Casing plastic according to UL94 V-0, black
Mounting clip for 35mm DIN rail, EN 50022
Fitting position vertical
Operating / Storage temperature -20 to +70°C (-4 to +158°F) / -45 to +70°C (-49 to +158°F)
Protection type / Protection class IP20 / II (double insulated)
Approvals VDE + UL File No. E150057 (according to UL499
in combination with UL508A)
Note other voltages on request
*Operating with voltages below 140VAC reduces heating performance by approx. 10%.
Heating capacity / Ambient temperature diagram CSF 060
Heatingcapacity(W)
Temperature (°C)
150W
100W
50W
1)ambient temperature - see Heating capacity / Ambient temperature diagram; 2)measured 50mm above protective grille; 3)tolerance of ± 5K;
Art. No.
Heating
capacity1)
Inrush current
max.
Air outlet
temperature2)
Switch-off
temperature3)
Starting
temperature3)
Dimensions
Weight
(approx.)
06001.0-00 50W 2.5A +86°C (186.8°F) +15°C (59°F) +5°C (41°F) 110 x 60 x 90mm 0.30kg
06002.0-00 50W 2.5A +86°C (186.8°F) +25°C (77°F) +15°C (59°F) 110 x 60 x 90mm 0.30kg
06011.0-00 100W 4.5A +120°C (248°F) +15°C (59°F) +5°C (41°F) 110 x 60 x 90mm 0.30kg
06012.0-00 100W 4.5A +120°C (248°F) +25°C (77°F) +15°C (59°F) 110 x 60 x 90mm 0.30kg
06021.0-00 150W 8A +145°C (293°F) +15°C (59°F) +5°C (41°F) 150 x 60 x 90mm 0.50kg
06022.0-00 150W 8A +145°C (293°F) +25°C (77°F) +15°C (59°F) 150 x 60 x 90mm 0.50kg
Example of connection
Heater CSF 060
90
23L60
Touch-Safe Heater CSF 060 Series 50W to 150W
(semiconductor)
Touch-safe heater for the use in enclosures with electrical/electronical components. The design
of the heater supports the natural convection which results in a high air-current of warm air. The
surface temperatures on the accessible side surfaces of the housing are kept down as a result
of the heater design. This model with plug-in thermostat does not require additional wiring. The
heaters are designed for permanent operation. This heater is also available in a version without
thermostat (CS 060).

Recomendados

Trace Heating Series Constant Wattage Trace Heating Cables por
Trace Heating Series Constant Wattage Trace Heating CablesTrace Heating Series Constant Wattage Trace Heating Cables
Trace Heating Series Constant Wattage Trace Heating CablesThorne & Derrick UK
1.2K vistas8 diapositivas
Eltherm ELP/Si-F Heat Trace Cable - Spec Sheet por
Eltherm ELP/Si-F Heat Trace Cable - Spec SheetEltherm ELP/Si-F Heat Trace Cable - Spec Sheet
Eltherm ELP/Si-F Heat Trace Cable - Spec SheetThorne & Derrick UK
235 vistas2 diapositivas
Nelson Easy Heat Self Regulating Heater Cables - Product Catalogue por
Nelson Easy Heat Self Regulating Heater Cables - Product CatalogueNelson Easy Heat Self Regulating Heater Cables - Product Catalogue
Nelson Easy Heat Self Regulating Heater Cables - Product CatalogueThorne & Derrick UK
801 vistas17 diapositivas
จำหน่าย Pressure Switch Norgren - นิวเมติก.com por
จำหน่าย Pressure Switch Norgren - นิวเมติก.comจำหน่าย Pressure Switch Norgren - นิวเมติก.com
จำหน่าย Pressure Switch Norgren - นิวเมติก.comDNTMb Inc.
2.7K vistas54 diapositivas
Eltherm ELK-AG-N Heat Trace Cable - Spec Sheet por
Eltherm ELK-AG-N Heat Trace Cable - Spec SheetEltherm ELK-AG-N Heat Trace Cable - Spec Sheet
Eltherm ELK-AG-N Heat Trace Cable - Spec SheetThorne & Derrick UK
227 vistas2 diapositivas
EasyHeat SR Heat Tracing Cable - Spec Sheet por
EasyHeat SR Heat Tracing Cable - Spec SheetEasyHeat SR Heat Tracing Cable - Spec Sheet
EasyHeat SR Heat Tracing Cable - Spec SheetThorne & Derrick UK
2.9K vistas2 diapositivas

Más contenido relacionado

La actualidad más candente

Trace Heating Cables Self Regulating - Installation Manual por
Trace Heating Cables Self Regulating - Installation ManualTrace Heating Cables Self Regulating - Installation Manual
Trace Heating Cables Self Regulating - Installation ManualThorne & Derrick UK
1.5K vistas19 diapositivas
Trace Heating Kits For Frost Protection Of Pipes Heatfast HF7005D - Spec Sheet por
Trace Heating Kits For Frost Protection Of Pipes Heatfast HF7005D - Spec SheetTrace Heating Kits For Frost Protection Of Pipes Heatfast HF7005D - Spec Sheet
Trace Heating Kits For Frost Protection Of Pipes Heatfast HF7005D - Spec SheetThorne & Derrick UK
241 vistas2 diapositivas
Bartec Heat Tracing Tape Self-limiting Hazardous Area Certified por
Bartec Heat Tracing Tape Self-limiting Hazardous Area CertifiedBartec Heat Tracing Tape Self-limiting Hazardous Area Certified
Bartec Heat Tracing Tape Self-limiting Hazardous Area CertifiedThorne & Derrick International
933 vistas4 diapositivas
Vacuum Oven - Laboratory or Process Scale por
Vacuum Oven - Laboratory or Process ScaleVacuum Oven - Laboratory or Process Scale
Vacuum Oven - Laboratory or Process ScaleAtlantic Technology Group, Inc.
265 vistas2 diapositivas
Isopad Flexible Heated Hoses, Gas Analyser Hose, Heavy Oil Transfer Hoses & B... por
Isopad Flexible Heated Hoses, Gas Analyser Hose, Heavy Oil Transfer Hoses & B...Isopad Flexible Heated Hoses, Gas Analyser Hose, Heavy Oil Transfer Hoses & B...
Isopad Flexible Heated Hoses, Gas Analyser Hose, Heavy Oil Transfer Hoses & B...Thorne & Derrick UK
278 vistas3 diapositivas
Heat tracing installation by Thermon por
Heat tracing installation by ThermonHeat tracing installation by Thermon
Heat tracing installation by ThermonCarotek
4.5K vistas10 diapositivas

La actualidad más candente(11)

Trace Heating Cables Self Regulating - Installation Manual por Thorne & Derrick UK
Trace Heating Cables Self Regulating - Installation ManualTrace Heating Cables Self Regulating - Installation Manual
Trace Heating Cables Self Regulating - Installation Manual
Thorne & Derrick UK1.5K vistas
Trace Heating Kits For Frost Protection Of Pipes Heatfast HF7005D - Spec Sheet por Thorne & Derrick UK
Trace Heating Kits For Frost Protection Of Pipes Heatfast HF7005D - Spec SheetTrace Heating Kits For Frost Protection Of Pipes Heatfast HF7005D - Spec Sheet
Trace Heating Kits For Frost Protection Of Pipes Heatfast HF7005D - Spec Sheet
Thorne & Derrick UK241 vistas
Isopad Flexible Heated Hoses, Gas Analyser Hose, Heavy Oil Transfer Hoses & B... por Thorne & Derrick UK
Isopad Flexible Heated Hoses, Gas Analyser Hose, Heavy Oil Transfer Hoses & B...Isopad Flexible Heated Hoses, Gas Analyser Hose, Heavy Oil Transfer Hoses & B...
Isopad Flexible Heated Hoses, Gas Analyser Hose, Heavy Oil Transfer Hoses & B...
Thorne & Derrick UK278 vistas
Heat tracing installation by Thermon por Carotek
Heat tracing installation by ThermonHeat tracing installation by Thermon
Heat tracing installation by Thermon
Carotek4.5K vistas
Winter Frost Protection Trace Heating Kit Heatfast HF7005 - Spec Sheet por Thorne & Derrick UK
Winter Frost Protection Trace Heating Kit Heatfast HF7005 - Spec SheetWinter Frost Protection Trace Heating Kit Heatfast HF7005 - Spec Sheet
Winter Frost Protection Trace Heating Kit Heatfast HF7005 - Spec Sheet
Thorne & Derrick UK2.4K vistas
Heatfast HF9225 Heat Tracing Junction Box - Spec Sheet por Thorne & Derrick UK
Heatfast HF9225 Heat Tracing Junction Box - Spec SheetHeatfast HF9225 Heat Tracing Junction Box - Spec Sheet
Heatfast HF9225 Heat Tracing Junction Box - Spec Sheet
Thorne & Derrick UK1.2K vistas
Thermon overview brochure for all Heat Tracing needs por Carotek
Thermon overview brochure for all Heat Tracing needsThermon overview brochure for all Heat Tracing needs
Thermon overview brochure for all Heat Tracing needs
Carotek2K vistas

Destacado

Articulo ondas didáctica por
Articulo ondas didácticaArticulo ondas didáctica
Articulo ondas didácticagatoleona
221 vistas9 diapositivas
Elementos básicos da comunicação visual ponto e por
Elementos básicos da comunicação visual    ponto eElementos básicos da comunicação visual    ponto e
Elementos básicos da comunicação visual ponto eDaniamargrit
1.8K vistas18 diapositivas
Expressão plástica 3ºA por
Expressão plástica 3ºAExpressão plástica 3ºA
Expressão plástica 3ºA_jaja
1.5K vistas16 diapositivas
Elementos estruturais 1 por
Elementos estruturais 1Elementos estruturais 1
Elementos estruturais 1Artedoiscmb Cmb
6.4K vistas25 diapositivas
Ponto e linha por
Ponto e linhaPonto e linha
Ponto e linhaElizete Iran
4.2K vistas9 diapositivas
Proposta de trabalho II - pontos, linhas e planos por
Proposta de trabalho II - pontos, linhas e planosProposta de trabalho II - pontos, linhas e planos
Proposta de trabalho II - pontos, linhas e planosCarina Lopes
3.3K vistas36 diapositivas

Destacado(14)

Articulo ondas didáctica por gatoleona
Articulo ondas didácticaArticulo ondas didáctica
Articulo ondas didáctica
gatoleona221 vistas
Elementos básicos da comunicação visual ponto e por Daniamargrit
Elementos básicos da comunicação visual    ponto eElementos básicos da comunicação visual    ponto e
Elementos básicos da comunicação visual ponto e
Daniamargrit1.8K vistas
Expressão plástica 3ºA por _jaja
Expressão plástica 3ºAExpressão plástica 3ºA
Expressão plástica 3ºA
_jaja1.5K vistas
Proposta de trabalho II - pontos, linhas e planos por Carina Lopes
Proposta de trabalho II - pontos, linhas e planosProposta de trabalho II - pontos, linhas e planos
Proposta de trabalho II - pontos, linhas e planos
Carina Lopes3.3K vistas
Simbologia das figuras geométricas por Liliana Oliveira
Simbologia das figuras geométricasSimbologia das figuras geométricas
Simbologia das figuras geométricas
Liliana Oliveira17.2K vistas
Elementos básicos da arte plástica por Joaninha Sena
Elementos básicos da arte plásticaElementos básicos da arte plástica
Elementos básicos da arte plástica
Joaninha Sena20.8K vistas
The Visual Elements Of An Image por isabelri
The Visual Elements Of An ImageThe Visual Elements Of An Image
The Visual Elements Of An Image
isabelri8.8K vistas
O ponto e a linha aula 6º ano - 2013 por Michele Wilbert
O ponto e a linha   aula 6º ano - 2013O ponto e a linha   aula 6º ano - 2013
O ponto e a linha aula 6º ano - 2013
Michele Wilbert48.1K vistas
Ponto e linha com imagens por Elizete Iran
Ponto e linha com imagensPonto e linha com imagens
Ponto e linha com imagens
Elizete Iran15.9K vistas
Conceito de Ponto, Linha e Plano por Débora Cseri
Conceito de Ponto, Linha e PlanoConceito de Ponto, Linha e Plano
Conceito de Ponto, Linha e Plano
Débora Cseri29K vistas

Similar a Heaters

Fan heaters por
Fan heatersFan heaters
Fan heatersJiandong Wu
612 vistas8 diapositivas
Regulators por
RegulatorsRegulators
RegulatorsJiandong Wu
580 vistas7 diapositivas
TSM487 por
TSM487TSM487
TSM487E-direct, Division of Endress+Hauser
481 vistas5 diapositivas
Eltherm ELKM-AG-L Heat Trace Cable - Spec Sheet por
Eltherm ELKM-AG-L Heat Trace Cable - Spec SheetEltherm ELKM-AG-L Heat Trace Cable - Spec Sheet
Eltherm ELKM-AG-L Heat Trace Cable - Spec SheetThorne & Derrick UK
367 vistas2 diapositivas
Eltherm ELW-H Heat Trace Cable - Spec Sheet por
Eltherm ELW-H Heat Trace Cable - Spec SheetEltherm ELW-H Heat Trace Cable - Spec Sheet
Eltherm ELW-H Heat Trace Cable - Spec SheetThorne & Derrick UK
262 vistas2 diapositivas
Nelson Heat Tracing Cables - Product Catalogue por
Nelson Heat Tracing Cables - Product CatalogueNelson Heat Tracing Cables - Product Catalogue
Nelson Heat Tracing Cables - Product CatalogueThorne & Derrick UK
2K vistas17 diapositivas

Similar a Heaters(20)

Eltherm ELKM-AG-L Heat Trace Cable - Spec Sheet por Thorne & Derrick UK
Eltherm ELKM-AG-L Heat Trace Cable - Spec SheetEltherm ELKM-AG-L Heat Trace Cable - Spec Sheet
Eltherm ELKM-AG-L Heat Trace Cable - Spec Sheet
Thorne & Derrick UK367 vistas
Eltherm ELKM-AG-N Heat Trace Cable - Spec Sheet por Thorne & Derrick UK
Eltherm ELKM-AG-N Heat Trace Cable - Spec SheetEltherm ELKM-AG-N Heat Trace Cable - Spec Sheet
Eltherm ELKM-AG-N Heat Trace Cable - Spec Sheet
Thorne & Derrick UK291 vistas
Omnigrad m tr10 endress+hauser datasheet-modular rtd assembly temperature por ENVIMART
Omnigrad m tr10 endress+hauser datasheet-modular rtd assembly temperatureOmnigrad m tr10 endress+hauser datasheet-modular rtd assembly temperature
Omnigrad m tr10 endress+hauser datasheet-modular rtd assembly temperature
ENVIMART100 vistas
Eltherm ELKM-AG-H Heat Trace Cable - Spec Sheet por Thorne & Derrick UK
Eltherm ELKM-AG-H Heat Trace Cable - Spec SheetEltherm ELKM-AG-H Heat Trace Cable - Spec Sheet
Eltherm ELKM-AG-H Heat Trace Cable - Spec Sheet
Thorne & Derrick UK275 vistas
Eltherm ELK-MI_CN Heat Trace Cable - Spec Sheet por Thorne & Derrick UK
Eltherm ELK-MI_CN Heat Trace Cable - Spec SheetEltherm ELK-MI_CN Heat Trace Cable - Spec Sheet
Eltherm ELK-MI_CN Heat Trace Cable - Spec Sheet
Thorne & Derrick UK290 vistas
Eltherm ELSR-Ramp Heat Trace Cable - Spec Sheet por Thorne & Derrick UK
Eltherm ELSR-Ramp Heat Trace Cable - Spec SheetEltherm ELSR-Ramp Heat Trace Cable - Spec Sheet
Eltherm ELSR-Ramp Heat Trace Cable - Spec Sheet
Thorne & Derrick UK324 vistas
Self regulating heating cable for industrial application. por berry chen
Self regulating heating cable for industrial application.Self regulating heating cable for industrial application.
Self regulating heating cable for industrial application.
berry chen77 vistas
Omnigrad s taf11, taf12x, taf16 endress+hauser datasheet-high temperature ass... por ENVIMART
Omnigrad s taf11, taf12x, taf16 endress+hauser datasheet-high temperature ass...Omnigrad s taf11, taf12x, taf16 endress+hauser datasheet-high temperature ass...
Omnigrad s taf11, taf12x, taf16 endress+hauser datasheet-high temperature ass...
ENVIMART92 vistas
Eltherm ELK-MI-INC Heat Trace Cable - Spec Sheet por Thorne & Derrick UK
Eltherm ELK-MI-INC Heat Trace Cable - Spec SheetEltherm ELK-MI-INC Heat Trace Cable - Spec Sheet
Eltherm ELK-MI-INC Heat Trace Cable - Spec Sheet
Thorne & Derrick UK164 vistas

Más de Jiandong Wu

Dc mini-breaker por
Dc mini-breakerDc mini-breaker
Dc mini-breakerJiandong Wu
495 vistas3 diapositivas
Capacitive switch por
Capacitive switchCapacitive switch
Capacitive switchJiandong Wu
439 vistas4 diapositivas
Vandal resistant-switch por
Vandal resistant-switchVandal resistant-switch
Vandal resistant-switchJiandong Wu
504 vistas17 diapositivas
Keypads por
KeypadsKeypads
KeypadsJiandong Wu
376 vistas10 diapositivas
Piezo switch por
Piezo switchPiezo switch
Piezo switchJiandong Wu
522 vistas11 diapositivas
KL5M new-3w-led-mining-light por
KL5M new-3w-led-mining-lightKL5M new-3w-led-mining-light
KL5M new-3w-led-mining-lightJiandong Wu
535 vistas1 diapositiva

Más de Jiandong Wu(17)

Dc mini-breaker por Jiandong Wu
Dc mini-breakerDc mini-breaker
Dc mini-breaker
Jiandong Wu495 vistas
Capacitive switch por Jiandong Wu
Capacitive switchCapacitive switch
Capacitive switch
Jiandong Wu439 vistas
Vandal resistant-switch por Jiandong Wu
Vandal resistant-switchVandal resistant-switch
Vandal resistant-switch
Jiandong Wu504 vistas
KL5M new-3w-led-mining-light por Jiandong Wu
KL5M new-3w-led-mining-lightKL5M new-3w-led-mining-light
KL5M new-3w-led-mining-light
Jiandong Wu535 vistas
Kl2 lma kl3lmc-kl3lmd-kl5lmc-rd400-rd500-t7a-t7b-led-mining-light por Jiandong Wu
Kl2 lma kl3lmc-kl3lmd-kl5lmc-rd400-rd500-t7a-t7b-led-mining-lightKl2 lma kl3lmc-kl3lmd-kl5lmc-rd400-rd500-t7a-t7b-led-mining-light
Kl2 lma kl3lmc-kl3lmd-kl5lmc-rd400-rd500-t7a-t7b-led-mining-light
Jiandong Wu438 vistas
Bc5200 bc9101 ab-bc9110ab-bc9302-zy8101ab-zy8110ab-zy8810-zy8820-emergency-li... por Jiandong Wu
Bc5200 bc9101 ab-bc9110ab-bc9302-zy8101ab-zy8110ab-zy8810-zy8820-emergency-li...Bc5200 bc9101 ab-bc9110ab-bc9302-zy8101ab-zy8110ab-zy8810-zy8820-emergency-li...
Bc5200 bc9101 ab-bc9110ab-bc9302-zy8101ab-zy8110ab-zy8810-zy8820-emergency-li...
Jiandong Wu339 vistas
Zw3500 ab zw3510ab-3500c-3510c-zw3520b-3520c-zw3530-light-tower por Jiandong Wu
Zw3500 ab zw3510ab-3500c-3510c-zw3520b-3520c-zw3530-light-towerZw3500 ab zw3510ab-3500c-3510c-zw3520b-3520c-zw3530-light-tower
Zw3500 ab zw3510ab-3500c-3510c-zw3520b-3520c-zw3530-light-tower
Jiandong Wu349 vistas
Bbd4200 bc9101 ab-9110ab-bc9200abc-bc9302ab-emergency-ex-light por Jiandong Wu
Bbd4200 bc9101 ab-9110ab-bc9200abc-bc9302ab-emergency-ex-lightBbd4200 bc9101 ab-9110ab-bc9200abc-bc9302ab-emergency-ex-light
Bbd4200 bc9101 ab-9110ab-bc9200abc-bc9302ab-emergency-ex-light
Jiandong Wu336 vistas
Dgs10 127-bc5400-bc9100-9101-bc9130-9300-9302-9303-9330-9550-9501-bc9700-fiex... por Jiandong Wu
Dgs10 127-bc5400-bc9100-9101-bc9130-9300-9302-9303-9330-9550-9501-bc9700-fiex...Dgs10 127-bc5400-bc9100-9101-bc9130-9300-9302-9303-9330-9550-9501-bc9700-fiex...
Dgs10 127-bc5400-bc9100-9101-bc9130-9300-9302-9303-9330-9550-9501-bc9700-fiex...
Jiandong Wu592 vistas
Zy5301 8100-8101-8130-8200-8220-8300-8301-8302-zy8310-fixed-professional-light por Jiandong Wu
Zy5301 8100-8101-8130-8200-8220-8300-8301-8302-zy8310-fixed-professional-lightZy5301 8100-8101-8130-8200-8220-8300-8301-8302-zy8310-fixed-professional-light
Zy5301 8100-8101-8130-8200-8220-8300-8301-8302-zy8310-fixed-professional-light
Jiandong Wu341 vistas
Zy8501 8510-8521-8530-8600-8601-8620-8630-8701-8720-8800 ab-zy9710-fixed-prof... por Jiandong Wu
Zy8501 8510-8521-8530-8600-8601-8620-8630-8701-8720-8800 ab-zy9710-fixed-prof...Zy8501 8510-8521-8530-8600-8601-8620-8630-8701-8720-8800 ab-zy9710-fixed-prof...
Zy8501 8510-8521-8530-8600-8601-8620-8630-8701-8720-8800 ab-zy9710-fixed-prof...
Jiandong Wu512 vistas
Kj35 lm kj45lm-kj6-7-8lm-led-mining-headlamp por Jiandong Wu
Kj35 lm kj45lm-kj6-7-8lm-led-mining-headlampKj35 lm kj45lm-kj6-7-8lm-led-mining-headlamp
Kj35 lm kj45lm-kj6-7-8lm-led-mining-headlamp
Jiandong Wu304 vistas
Kl4lm kl5lmab-kl6lm-bw6200ce-miner-cap-lamp-wrestt por Jiandong Wu
Kl4lm kl5lmab-kl6lm-bw6200ce-miner-cap-lamp-wresttKl4lm kl5lmab-kl6lm-bw6200ce-miner-cap-lamp-wrestt
Kl4lm kl5lmab-kl6lm-bw6200ce-miner-cap-lamp-wrestt
Jiandong Wu390 vistas
Bw4100-bw6200ce-bw6310ab-bw6610a-explosion-proof-headlight-wrestt por Jiandong Wu
Bw4100-bw6200ce-bw6310ab-bw6610a-explosion-proof-headlight-wresttBw4100-bw6200ce-bw6310ab-bw6610a-explosion-proof-headlight-wrestt
Bw4100-bw6200ce-bw6310ab-bw6610a-explosion-proof-headlight-wrestt
Jiandong Wu327 vistas
Explosion proof torchlight bw7500abc (wrestt) por Jiandong Wu
Explosion proof torchlight bw7500abc (wrestt)Explosion proof torchlight bw7500abc (wrestt)
Explosion proof torchlight bw7500abc (wrestt)
Jiandong Wu221 vistas

Heaters

  • 1. ++ Wrestt Group Co.,Ltd. +Rm 302,Hongya Jingyuan,Wuniu,Wenzhou China 325603 + sales@wrestt.com + www.kirsting.com ++ ++ These heaters are used in enclosures where damage from condensation must be prevented, or where the temperature may not fall below a minimum value. The aluminium profile heater body design has a chimney effect and distributes the heat evenly. The pressure clamp connectors save time and simplify installation. Pressure clamp connectors Dynamic heating up Wide voltage range Temperature limiting Energy saving Clip fixing Quick installation Heating Semiconductor Heater HG 140 Series 15W to 150W Technical Data Operating voltage 120-250V AC/DC* Heating element PTC resistor, self regulating and temperature limiting Heater body extruded aluminium profile, anodised Connection 3 pressure clamps for stranded wire 0.5-1.5mm² (with wire end ferrule) and rigid wire 0.5-2.5mm² Connection casing plastic according to UL94 V-0, black Mounting clip for 35mm DIN rail, EN 50022 Fitting position vertical Operating/Storage temperature -45 to +70°C (-49 to +158°F) Protection type / Protection class IP20 / I (earthed) Approvals VDE, UL File No. E150057 Accessories screw fixing, Art. No. 09024.0-00 (1 packing unit = 2 pieces) *Operating with voltages below 140V AC/DC reduces heating performance by approx. 10%. Art. No. Heating capacity* Inrush current max. Length (L) Weight (approx.) 14000.0-00 15W 1.5A 65mm 0.30kg 14001.0-00 30W 3.0A 65mm 0.30kg 14003.0-00 45W 3.5A 65mm 0.30kg 14005.0-00 60W 2.5A 140mm 0.40kg 14006.0-00 75W 4.0A 140mm 0.50kg 14007.0-00 100W 4.5A 140mm 0.50kg 14008.0-00 150W 9.0A 220mm 0.70kg *at 20°C (68°F) ambient temperature C
  • 2. The heaters are used in enclosures where condensation is to be prevented or the temperature may not fall below a minimum value. In this way corrosion is avoided and an even temperature is ensured. Technical Data Dynamic heating up Energy saving Wide voltage range Temperature limiting Clip fixing Heating Small semiconductor Heater HGK 047 Series 10W to 30W L N Example of connection Heater HGK 047KTO 011 (contact breaker, normally closed) 50 25 21003L Clip for 35mm DIN rail Art. No. Operating voltage Heating capacity1) Inrush current max. Length (L) Weight (approx.) Connection Approvals 04700.0-00 120-250V AC/DC2) 10W 1.0A 50mm 0.10kg 3 x 0.5mm² x 300mm sheathed cable (silicone) VDE 04701.0-00 120-250V AC/DC2) 20W 2.5A 60mm 0.20kg 3 x 0.5mm² x 300mm sheathed cable (silicone) VDE 04702.0-00 120-250V AC/DC2) 30W 3.0A 70mm 0.20kg 3 x 0.5mm² x 300mm sheathed cable (silicone) VDE 04700.9-00 110-120V AC/DC 10W 1.0A 50mm 0.10kg 3 x AWG 20 x 300mm sheathed cable UL File No. E150057 04701.9-00 110-120V AC/DC 20W 1.5A 60mm 0.20kg 3 x AWG 20 x 300mm sheathed cable UL File No. E150057 04702.9-00 110-120V AC/DC 30W 1.5A 70mm 0.20kg 3 x AWG 20 x 300mm sheathed cable UL File No. E150057 1) at 20°C (68°F) ambient temperature 2) Operating with voltages below 140V AC/DC reduces heating performance by approx. 10%. Heating element PTC resistor, self regulating and temperature limiting Heater body extruded aluminium profile, anodised Mounting clip for 35mm DIN rail, EN 50022 Fitting position vertical Operating/Storage temperature -45 to +70°C (-49 to +158°F) Protection type / Protection class IP54 / I (earthed) Accessories screw fixing, Art. No. 09024.0-00 (1 packing unit = 2 pieces) C ++ Wrestt Group Co.,Ltd. +Rm 302,Hongya Jingyuan,Wuniu,Wenzhou China 325603 + sales@wrestt.com + www.kirsting.com ++ ++
  • 3. Small heaters designed to prevent condensation and to ensure a minimum operating temperature in small enclosures. Technical Data Temperature limiting Wide voltage range Dynamic heating up Energy saving Compact Heating Art. No. Heating capacity* Inrush current max. Surface temperature (approx.) Connection Weight (approx.) 01622.0-00 5W 2.0A 165°C 2 x AWG 22 sheathed cable (silicone) 20g 01623.0-00 9W 2.5A 175°C 2 x AWG 22 sheathed cable (silicone) 20g *at 20°C (68°F) ambient temperature Connection 2 x AWG 22 sheathed cable (silicone) L N Example of connection Heater RCE 016KTO 011 (contact breaker, normally closed) Mounting clips Art. No. 09008.0-01 (1 packing unit = 2 pieces) Small semiconductor Heater RCE 016 Series 5W, 9W Operating voltage 120-250V AC/DC* Heating element PTC resistor, self regulating and temperature limiting Heater body aluminium Mounting see Accessories Fitting position variable Operating/Storage temperature -45 to +70°C (-49 to +158°F) Dimensions length 45mm, Ø 10mm Protection type / Protection class IP32 / II (double insulated) Approvals VDE, UL File No. E150057 Accessories mounting clips (see illustration) Note other voltages on request *Operating with voltages below 140V AC/DC reduces heating performance by approx. 10%. C ++ Wrestt Group Co.,Ltd. +Rm 302,Hongya Jingyuan,Wuniu,Wenzhou China 325603 + sales@wrestt.com + www.kirsting.com ++ ++
  • 4. These small heaters are designed to prevent condensation and to ensure a minimum operating temperature in small enclosures. Temperature limiting Wide voltage range Dynamic heating up Energy saving Compact Heating Small semiconductor Heater RC 016 Series 8W, 10W, 13W Technical Data Operating voltage 120-250V AC/DC* Heating element PTC resistor, self regulating and temperature limiting Heater body aluminium, anodised Mounting screw fixing Fitting position variable Operating/Storage temperature -45 to +70°C (-49 to +158°F) Protection type / Protection class IP32 / II (double insulated) Approvals VDE, UL File No. E150057 Note other voltages on request *Operating with voltages below 140V AC/DC reduces heating performance by approx. 10%. Art. No. Heating capacity* Inrush current max. Surface temperature (approx.) Connection Weight (approx.) 01602.0-00 8W 2.0A 150°C 2 x AWG 18 stranded wire 20g 01609.0-00 10W 2.5A 155°C 2 x AWG 22 sheathed cable (silicone) 30g 01610.0-00 13W 3.0A 170°C 2 x AWG 22 sheathed cable (silicone) 40g *at 20°C (68°F) ambient temperature Art. No. 01602.0-00: Connection 2 x AWG 18 stranded wire Art. No. 01609.0-00: Connection 2 x AWG 22 sheathed cable (silicone) Art. No. 01610.0-00: Connection 2 x AWG 22 sheathed cable (silicone) L N Example of connection Heater RC 016 KTO 011 (contact breaker, normally closed) C ++ Wrestt Group Co.,Ltd. +Rm 302,Hongya Jingyuan,Wuniu,Wenzhou China 325603 + sales@wrestt.com + www.kirsting.com ++ ++
  • 5. ++ Wrestt Group Co.,Ltd. +Rm 302,Hongya Jingyuan,Wuniu,Wenzhou China 325603 + sales@wrestt.com + www.kirsting.com ++ ++ Heating The heaters are used in enclosures where condensation is to be prevented or the temperature may not fall below a minimum value. In this way corrosion is avoided and an even temperature is ensured. The heaters are designed for permanent operation. Technical Data Low surface temperature Double insulated (plastic housing) Wide voltage range Temperature limiting Dynamic heating up Clip fixing Touch-Safe Small Heater CSK 060 Series 10W, 20W (Semiconductor) Example of connection Heater CSK 060 Thermostat FTO 011 (contact breakter, normally closed) * at 20°C (68°F) ambient temperature Operating voltage 120 - 240V AC/DC* (min. 110V, max. 265V) Heating element PTC resistor - temperature limiting Surface temperature < 85°C (185°F) (according to VDE 0100), except upper protective grille Connection 2-pole terminal 2.5mm², torque 0.8Nm max. Casing plastic according to UL94 V-0, black Dimensions 98 x 38 x 75mm Mounting clip for 35mm DIN rail, EN 50022 Fitting position vertical Operating/ Storage temperature -45°C to +70°C (-49°F to +158°F) Protection type / Protection class IP20 / II (double insulated) Approvals VDE + UL File No. E150057 (according to UL499 in combination with UL508A) Note other voltages on request *Operating with voltages below 140V AC/DC reduces heating performance by approx. 10%. Art. No. Heating capacity* Inrush current max. Weight (approx.) 06040.0-00 10W 1.0A 0.20kg 06030.0-00 20W 2.5A 0.30kg
  • 6. Heater 50 0 200 150 100 Heizleistung(W) -40 -20 0 8 P J HE X Q J V WHP S HUD WX U e & Leistungs-Umgebungstemperatur-Diagramm CS 160 20 40 Art. Nr. 16000.0-0 Art. Nr. 16010.0-0 Art. Nr. 16020.0-0 178 160 147 132 119122 110 102 93 85 66 61 55 50 44 Low surface temperature Quick mounting due to clip fixing Double insulated (plastic) Wide voltage range Small size Technical Data Operating voltage 120-240V AC/DC* (min. 110V, max. 265V) Heating capacity see table Heating element PTC resistor - temperature limiting Surface temperature < 80°C (176°F), except upper protective grille Connection 4-pole terminal 2,5mm², torque 0.8Nm max. Casing plastic according to UL94 V-0, black Mounting clip for 35mm DIN rail, EN 50022 Fitting position vertical Operating / Storage temperature -45 to +70°C (-49 to +158°F) Protection type / Protection class IP20 / II (double insulated) Approvals VDE + UL File No. E150057 (according to UL499 in combination with UL508A) Note other voltages on request *Operating with voltages below 140V AC/DC reduces heating performance by approx. 10%. 1)ambient temperature - see Heating capacity / Ambient temperature diagram; 2)measured 50mm above protective grille; Heating capacity / Ambient temperature diagram CS 060 Heatingcapacity(W) Temperature (°C) 150W 100W 50W Art. No. Heating capacity1) Inrush current max. Air outlet temperature2) Dimensions Weight (approx.) 06000.0-00 50W 2.5A +86°C (186.8°F) 110 x 60 x 90mm 0.30kg 06010.0-00 100W 4.5A +120°C (248°F) 110 x 60 x 90mm 0.30kg 06020.0-00 150W 8A +145°C (293°F) 150 x 60 x 90mm 0.50kg Examples of connection Heater CS 060 Thermostat FTO 011 Heater CS 060 AC AC Heater CS 060 Thermostat FTO 011 Touch-safe heater for the use in enclosures with electrical/electronical components. The design of the heater supports the natural convection which results in a high air-current of warm air. The surface temperatures on the accessible side surfaces of the housing are kept down as a result of the heater design. Our complete range of thermostats and hygrostats can directly be connected to the heater CS 060. This heater is also available in a version with plug-in thermostat requiring no additional wiring (CSF 060). Both versions are designed for permanent operation. Touch-Safe Heater CS 060 Series 50W to 150W (semiconductor) ++ Wrestt Group Co.,Ltd. +Rm 302,Hongya Jingyuan,Wuniu,Wenzhou China 325603 + sales@wrestt.com + www.kirsting.com ++ ++
  • 7. ++ Wrestt Group Co.,Ltd. +Rm 302,Hongya Jingyuan,Wuniu,Wenzhou China 325603 + sales@wrestt.com + www.kirsting.com ++ ++ Heating 50 0 200 150 100 Heizleistung(W) -40 -20 0 8 P J HE X Q J V WHP S HUD WX U e & Leistungs-Umgebungstemperatur-Diagramm CS 160 20 40 Art. Nr. 16000.0-0 Art. Nr. 16010.0-0 Art. Nr. 16020.0-0 178 160 147 132 119122 110 102 93 85 66 61 55 50 44 Low surface temperature Integrated thermostat Quick mounting due to clip fixing Double insulated (plastic) Wide voltage range Small size Technical Data Operating voltage 120-240VAC* (min. 110V, max. 265V) Heating capacity see table Heating element PTC resistor - temperature limiting Surface temperature < 80°C (176°F), except upper protective grille Connection 4-pole terminal 2,5mm², torque 0.8Nm max. Casing plastic according to UL94 V-0, black Mounting clip for 35mm DIN rail, EN 50022 Fitting position vertical Operating / Storage temperature -20 to +70°C (-4 to +158°F) / -45 to +70°C (-49 to +158°F) Protection type / Protection class IP20 / II (double insulated) Approvals VDE + UL File No. E150057 (according to UL499 in combination with UL508A) Note other voltages on request *Operating with voltages below 140VAC reduces heating performance by approx. 10%. Heating capacity / Ambient temperature diagram CSF 060 Heatingcapacity(W) Temperature (°C) 150W 100W 50W 1)ambient temperature - see Heating capacity / Ambient temperature diagram; 2)measured 50mm above protective grille; 3)tolerance of ± 5K; Art. No. Heating capacity1) Inrush current max. Air outlet temperature2) Switch-off temperature3) Starting temperature3) Dimensions Weight (approx.) 06001.0-00 50W 2.5A +86°C (186.8°F) +15°C (59°F) +5°C (41°F) 110 x 60 x 90mm 0.30kg 06002.0-00 50W 2.5A +86°C (186.8°F) +25°C (77°F) +15°C (59°F) 110 x 60 x 90mm 0.30kg 06011.0-00 100W 4.5A +120°C (248°F) +15°C (59°F) +5°C (41°F) 110 x 60 x 90mm 0.30kg 06012.0-00 100W 4.5A +120°C (248°F) +25°C (77°F) +15°C (59°F) 110 x 60 x 90mm 0.30kg 06021.0-00 150W 8A +145°C (293°F) +15°C (59°F) +5°C (41°F) 150 x 60 x 90mm 0.50kg 06022.0-00 150W 8A +145°C (293°F) +25°C (77°F) +15°C (59°F) 150 x 60 x 90mm 0.50kg Example of connection Heater CSF 060 90 23L60 Touch-Safe Heater CSF 060 Series 50W to 150W (semiconductor) Touch-safe heater for the use in enclosures with electrical/electronical components. The design of the heater supports the natural convection which results in a high air-current of warm air. The surface temperatures on the accessible side surfaces of the housing are kept down as a result of the heater design. This model with plug-in thermostat does not require additional wiring. The heaters are designed for permanent operation. This heater is also available in a version without thermostat (CS 060).