You control the dial
Philips CT iDose4 iterative reconstruction technique
The results you want
                            Philips iDose4 is an iterative reconstruction technique that gives you control
                            of the dial so you can personalize image quality based on your patients’ needs
                            at low dose. When used in combination with the advanced technologies of
                            the iCT, Ingenuity, and Brilliance CT scanner families, this provides a unique
                            approach to managing important factors in patient care – low energy, low
                            dose, and low injected contrast imaging.


                                          Which setting do you need?
                                                      Increase resolution with low dose
                                                      120 kVp; 150 mAs
                                                      CTDIvol – 10.2 mGy
                                                      DLP – 187 mGy xcm
                                                      Effective dose – 0.6 mSv*


                                                       Improve spatial
                                                        resolution at
                                                        a lower dose




  Significantly                                                                                               Reduce dose
improve spatial                                                                                               even further
 resolution at                                                                                                without the
the same dose                                                                                                  plastic look
   Significantly improve resolution                                                                Manage dose without sacrificing
   120 kVp; 100 mAs                                                                                image quality
   CTDIvol – 6.5 mGy                                                                               80 kVp; 10 mAs
   DLP – 136 mGy xcm                                                                               CTDIvol (32cm) – 0.21 mGy
   Effective dose – 2 mSv*                                                                         DLP – 2.9 mGy xcm
                                                                                                   Effective dose – 0.16 mSv*




   2          *AAPM technical report 96
at the speeds you need
 If it’s fast, it’s Philips
 A majority of reference protocols are
 reconstructed in under 60 seconds with
 iDose4 iterative reconstruction technique.

                                              With iDose4, reconstruction is achieved in seconds rather
                                              than minutes. This is due to the innovative RapidView
                                              IR reconstruction engine. Designed to suppor t iDose4,
                                              this proprietary technology allows for this iterative
                                              reconstruction technique to be used routinely in inpatient,
                                              outpatient, and emergency care settings. With the
                                              combination of iDose4 and RapidView IR, the majority of all
                                              factory protocols are reconstructed in 60 seconds or less.
                                              The design seamlessly integrates into your CT department,
                                              and provides you the look and feel of conventional higher
                                              dose images without long processing times.




                                              RapidView IR
                                              Philips Proprietary, state-of-the-art parallel architecture




                                                     Philips high performance computational core is
                                                     equivalent to the power of hundreds of computers.




 119 cm reconstructed in 49.5 seconds

                                                                                                            3
The iDose                                                                                                          4
                                            Clinical integration                       Patient focus                            Improve economic value
                                            and collaboration                          • Personalize image quality              •	High throughput
                                            •	Improve image quality*                   	 based on patients’ needs               •	Streamline workflow
                                            •	Preserve “natural”                       	 at low dose                            •	Easy to adopt into existing
                                              appearance                               •  anage dose without
                                                                                         M                                        standard of care
                                            •	Robust artifact prevention                 sacrificing image quality              •	Availability across majority
                                            •	Fast reconstruction speed                • Applicable to majority                   of product portfolio
                                                                                       	 of clinical conditions




                                            What is Imaging 2.0?
                                            Web 2.0 described the evolution of the web from being data-driven to user-centric, redefining
                                            the way people connect, share, and use the Internet. Imaging 2.0 is doing the same, bringing
                                            a new world of possibilities for radiology. It is about integration and collaboration, and new
                                            levels of patient focus and care that can help clinicians achieve what was unimaginable just
                                            a few short years ago.




4   *mproved image quality as defined by improvements in spatial resolution and/or noise reduction as measured in phantom studies.
     I
advantage
                                            The evolution of reconstruction


                                            Generation 4 – Advanced iterative reconstruction technique
                                            Preserved “natural” appearance I Robust artifact prevention I Improved image quality *



                     3               3
                                    erat
                                        ion
                                                        Generation 3 – Basic iterative reconstruction technique
                                                        Artifact reduction
                                 Gen

                                                                  Generation 2 – Image based filtering/denoising
              2                           2  ion
                                                                  Removal of some image noise
                                         erat
                                      Gen
                                                                             Generation 1 – Standard reconstruction without iDose4
         1                                       1  ion
                                                                             Fast

                                                erat
                                             Gen




          Philips iDose4 (4th-generation reconstruction) provides key clinical benefits**
          Improved image quality*                            Up to 57% improvement in spatial resolution
          Preserved natural image appearance                 Less than 5% noise-power-spectrum shift
          Robust artifact prevention                         Low signal streak correction
          Protocol integration                               Axial, helical, ECG- and pulmonary-gated, dual-energy, and perfusion
                                                             Standard, high, and ultrahigh resolution
                                                             5122 , 7682 , and 10242 image matrix sizes
          Flexible                                           7 distinct, user-selectable levels that support image quality personalization
                                                             based on your clinical needs
          Fast                                               With RapidView IR, reconstruction is achieved in seconds rather than minutes.
                                                             The majority of reference protocols are reconstructed in under 1 minute.



                                             “I think that iDose4 is going to be the future for everyone
                                              in the sense that I can honestly think of no reason why you
                                              would not use it in your practice if you have it available.”
                                              Barry D. Daly, MD
                                              University of Maryland Medical Center, Baltimore, MD


 	 *	 Improved image quality as defined by improvements in spatial resolution and/or noise reduction as measured in phantom studies.
 	 **	 Results may vary based on scanner model.                                                                                              5
Scanner benefits
                                          Pulmonary imaging with
                                            increased resolution                                                    Bariatric imaging with
                                                                                                                   improved image quality*




                                     High resolution              High resolution
                                      iDose 4: OFF               iDose4: Level 7
                                                                                                                iDose 4: OFF       iDose4: Level 3




         Neuro imaging with
     increased contrast-to-noise
                                                                          Improve image
                                                                           quality* and
                                                                             preserve
                                                                             “natural”
                                                                            appearance                                  Orthopedic imaging with
    iDose 4: OFF              iDose4: Level 3
                                                                                                                     reduced artifacts from implants



                                                    Coronary imaging with
                                                     increased resolution




                                                                                                             iDose 4: OFF       O-MAR +            O-MAR +
                                                                                                                               iDose 4: OFF      iDose4: Level 7




                                                  iDose 4: OFF          iDose4: Level 7




6         *Improved image quality as defined by improvements in spatial resolution and/or noise reduction.
enabled by iDose                                                                                     4

                             Manage dose without
                            sacrificing image quality




    Routine chest X-ray      80 kVp, 10 mAs,               80 kVp, 10 mAs,
         0.06 mSv           0.2 mGy, 0.08 mSv            0.2 mGy, 0.08 mSv
                               iDose 4: OFF               iDose4: Level 3

                                                                                         Quantitative imaging
                                                                                            at low-dose
                                                                                   CBV         CBF        MTT   TTP




  Robust artifact
                                                             80 kVp
                                                             125 mAs                                                  iDose 4: OFF
                                                             iDose 4: OFF




 prevention and
 noise reduction.                                                                                                     iDose4: Level 7
                                                             80 kVp
                                                             31 mAs
                                                             iDose 4: Level 7




 Fast and seamless                                           80 kVp
                                                             31 mAs                                                   iDose 4: OFF

    integration.
                                                             iDose 4: OFF



                                                             Low-Dose Simulation




               Trauma imaging                           Low energy imaging when combined
            with reduced artifacts                      with advanced scanner technologies




                                                         120 kVp, 100 mAs,                   80 kVp, 130 mAs,
                                                          6.6 mGy, 9.6 mSv                   2.7 mGy, 2.8 mSv
       iDose 4: OFF       iDose4: Level 4
                                                             Nov 2009                           April 2010
                                                            iDose 4: OFF                     iDose4: Level 4




                                                                                                                                     7
Manage dose without sacrificing image quality


    Low dose acquisitions are often associated
    with streak artifacts. Basic iterative
    reconstruction techniques may provide
    some incremental benefit in reducing these
    artifacts; however, iDose4 – an advanced
    iterative reconstruction technique – prevents
    these artifacts and improves image quality**
    in this Step  Shoot Cardiac scan.


    Scan parameters
    •	100 kVp
    •	17 mAs
    •	Coverage – 18.7 cm
    •	iDose4 – Level 4
    •	CTDIvol – 0.8 mGy
    •	DLP – 15.7 mGy xcm
    •	Effective dose – 0.2 mSv*
    •	Reconstruction time – 32 s (415 images)
    •	Scanner – iCT




    Pediatric patients undergoing frequent
    follow-up imaging benefit from low-energy,
    low-dose and high image quality. This high-
    heart-rate, sub-mSv follow-up study was
    performed on a non-sedated patient using
    the iCT with iDose4, resulting in low signal
    streak correction and high image quality.


    Scan parameters
    •	80 kVp
    •	100 mAs
    •	Coverage – 10.3 cm
    •	Heart rate – 143 bpm
    •	Scan time – 6.6 s
    •	iDose4 – Level 3
    •	CTDIvol – 2.2 mGy
    •	DLP – 22.6 mGy xcm
    •	Reconstruction time – 12 s
    •	Scanner – iCT




     *AAPM technical report 96
8   **Improved image quality as defined by improvements in spatial resolution and/or noise reduction.
Quantitative imaging below background radiation dose


    Perfusion scans may result in relatively high
    patient dose due to repeated scanning of
    the same structure over time. In this case,
    low-dose scanner technologies combined
    with iDose4 helped manage dose without
    sacrificing image quality.


    Scan parameters
    •	80 kVp
    •	31 mAs**
    •	Coverage – 8 cm
    •	iDose4 – Level 7
    •	CTDIvol – 1.2 mGy x 40
    •	DLP – 9.6 mGy xcm x 40
    •	Effective dose – 0.8 mSv*
    •	Scanner – iCT




    The primary rationale to move from
    retrospective to prospective ECG-gated cardiac
    CTA acquisitions was to enable low-dose
    acquisitions at the expense of losing functional
    information. Low-energy scanner technologies
    combined with iDose4 resulted in full cardiac
    assessment at dose levels equivalent to back-
    ground radiation without sacrificing image quality.


    Scan parameters
    •	100 kVp	
    •	273 mAs
    •	Coverage – 16.5 cm
    •	Scan time – 6.3 s
    •	Resolution – 12.3 lp/cm
    •	iDose4 – Level 4
    •	CTDIvol – 10.5 mGy
    •	DLP – 223.2 mGy xcm
    •	Effective dose – 3.1 mSv*
    •	Reconstruction time – 91 s (1,155 images)
    •	Scanner – iCT

     *AAPM technical report 96
    **Simulated from 125 mAs acquisition                  9
Improve resolution of cardiac imaging


     Limited resolution on cardiac CTA acquisitions
     can hinder visualization of the coronary
     lumen in the presence of heavy calcified
     plaque or coronary stents. This can be
     particularly challenging when balancing
     the low-dose needs of the patient. iDose 4
     significantly improves spatial resolution at
     low dose.


     Scan parameters
     •	80 kVp
     •	195 mAs
     •	Coverage – 13.5 cm
     •	Scan time – 4.5 s
     •	iDose4 – Level 4
     •	CTDIvol – 4.2 mGy
     •	DLP – 56.7 mGy xcm
     •	Effective dose – 0.8 mSv*
     •	Scanner – iCT




     Leveraging the low-dose capabilities of Step
      Shoot Cardiac with the high-resolution
     capabilities of iDose4, the study provides
     improved visualization.


     Scan parameters
     •	120 kVp
     •	200 mAs
     •	Coverage – 12.5 cm
     •	Scan time – 7.9 s
     •	Heart rate – 51 bpm
     •	iDose4 – Level 6
     •	CTDIvol – 16.8 mGy
     •	DLP – 210.0 mGy xcm
     •	Effective dose – 2.9 mSv*
     •	Scanner – Ingenuity CT




10   *AAPM technical report 96
Improve resolution and artifact prevention
in orthopedic imaging
    CT imaging of patients with orthopedic
    implants often results in loss of anatomical
    information due to a combination of artifacts.
    O-MAR reduces artifacts caused by large
    orthopedic implants and iDose4 improves
    image quality.


    Scan parameters
    •	140 kVp
    •	145 mAs/slice
    •	Coverage – 25.6 cm
    •	O-MAR – on
    •	iDose4 – Level 4
    •	Scanner – Brilliance 64




    The noise-resolution correlation on standard
    reconstruction techniques previously required
    trade-offs between dose and resolution.
    Breaking this connection, iDose4 provides
    high-resolution with low-noise in this
    low-dose study.


    Scan parameters
    •	120 kVp
    •	100 mAs
    •	Coverage – 15.3 cm
    •	Focal spot resolution – high
    •	Image matrix – 768 x 768
    •	iDose4 – Level 3
    •	CTDIvol – 6.5 mGy
    •	DLP – 136 mGy xcm
    •	Effective dose – 2 mSv*
    •	Scanner – Ingenuity CT




    *AAPM technical report 96                        11
Improve resolution in oncology imaging


     In radiation oncology, clinical needs are
     particularly focused towards accurate
     treatment planning, which ties into the
     need to have increased image quality.
     The increased contrast-to-noise in this
     study helps improve visualization.


     Scan parameters
     •	120 kVp
     •	500 mAs
     •	Coverage – 24 cm
     •	iDose4 – Level 1
     •	Scanner – Brilliance CT Big Bore




     In oncology patients, improved image quality
     plays an important part in accurate treatment
     planning. The image quality benefits of iDose4
     extend across a majority of the CT product
     portfolio, to include the Brilliance CT 16-slice.


     Scan parameters
     •	120 kVp
     •	200 mAs/slice
     •	Coverage – 34.2 cm
     •	iDose4 – Level 4
     •	Scanner – Brilliance 16




12
Improve image quality in noisy acquisitions


    Bariatric imaging is prone to increased
    image noise and artifacts (streaks and bias).
    Standard reconstruction and basic iterative
    reconstruction techniques are particularly
    limited in addressing artifacts. iDose4 advanced
    iterative reconstruction technique helps
    reduce noise and prevent artifacts.


    Scan parameters
    •	120 kVp
    •	190 mAs
    •	Coverage – 56.5 cm
    •	Scan time – 6.3 s
    •	iDose4 – Level 7
    •	Scanner – iCT




    Quantitative analysis of iodine enhancement was
    performed on the dual-energy data in delayed phase
    images relative to liver parenchyma. One lesion
    demonstrated washout in the delayed enhancement
                                                                           Increasing Iodine
    phase, subsequent to early enhancement in the                          Concentration
    arterial phase.The other lesion demonstrated central
    hypoenhancement in the delayed phase and other
    phases.The use of the iDose4 iterative reconstruction
    technique reduced image noise and allowed greater
    detail to be seen in the quantitative analysis.
                                                            HU 80 kVp




                                                                                  3
    Scan parameters
    •	80/140 kVp                                                             2
    •	460/90 mAs
    •	Collimation – 64 x 0.625 mm
                                                                         1
    •	iDose4 – Level 4
    •	DLP – 75.2 mGy xcm
                                                                        HU 140 kVp
    •	CTDIvol – 9.4 x2 mGy
    •	Effective dose – 1.1 mSv*
    •	Scanner - iCT



    *AAPM technical report 96                                                                  13
The results you want, at the speeds you need


     Low-energy imaging allows for increased
     iodinated contrast resolution at low dose;
     however, low-energy techniques often result
     in increased artifacts in larger patients.
     Ingenuity CT with iDose 4 provides robust
     artifact prevention in low-energy acquisitions,
     even in large patients.


     Scan parameters
     •	80 kVp
     •	135 mAs avg.
     •	Coverage – 59.5 cm
     •	Scan time – 10.3 s
     •	iDose4 – Level 6
     •	CTDIvol – 2.6 mGy
     •	DLP – 169.5 mGy xcm
     •	Effective dose – 2.5 mSv*
     •	Reconstruction time – 148 s 		
       (1,181 images)
     •	Scanner – Ingenuity CT




     Emergency and trauma imaging are highly
     demanding in terms of artifacts that may
     impact image quality and time to diagnosis.
     iDose4 reduces artifacts in images. This can
     be helpful in imaging patients who cannot lift
     their arms due to positioning requirements,
     weakness, or injury.


     Scan parameters
     •	120 kVp
     •	39 mAs
     •	Coverage – 157.7 cm
     •	Scan time – 50.4 s
     •	Focal spot resolution – high
     •	iDose4 – Level 5
     •	CTDIvol – 2.6 mGy
     •	DLP – 428 mGy xcm
     •	Effective dose – 6.4 mSv*
     •	Scanner – Ingenuity CT




14   *AAPM technical report 96
On the SmartPath with you
We understand how critical it is to elevate quality and efficiency in your daily work routine. And Philips
SmartPath is your way to obtain access to the latest innovations throughout the cycle of your ownership.


We are committed to bringing the benefits of iterative reconstruction technique to all. This is why
we designed an iDose4 upgrade to put you at the forefront of clinical innovations and workflow
efficiencies, and expand the clinical capabilities of your current system.




         iDose4 is available across the iCT, Ingenuity,
         and Brilliance CT families

                               iCT TVI       • iCT • iCT SP




                               Ingenuity CT          • Ingenuity Core128 • Ingenuity Core


                               Brilliance CT 64-channel with Essence technology                           • Brilliance CT 64-channel
                               Brilliance CT 40-channel   • Brilliance CT Big Bore
                                                                      *                                   *


                               Brilliance CT 16-slice*† • Brilliance CT 10-slice* • Brilliance CT 6-slice*†




    Philips SmartPath provides you easy access to solutions and innovations for the
    full life of your computed tomography system, so you can boost your clinical
    and operational potential and achieve your organizational goals.
                      Optimize your system’s                               Enhance your equipment                   Transform your investment
                      performance both now                                 with regular technology                  at the end of your system’s life
                      and in the future with regular                       upgrades, and take                       by transitioning seamlessly
                      and ongoing updates, including                       advantage of the newest                  to a next-generation solution
                      functionality improvements                           features and capabilities.               or refurbished option.
     Optimize         and remote technical support.          Enhance                                    Transform




	 *	May require prerequisite upgrade for iDose4 eligibility. Air-cooled scanners only.
		Please contact your local Philips representative for availability and prerequisite requirements.
	 †	8 MHU X-ray tube configuration prerequisite.                                                                                                       15
Philips Healthcare is part of
Royal Philips Electronics


How to reach us
www.philips.com/healthcare
healthcare@philips.com


Asia
+49 7031 463 2254


Europe, Middle East, Africa
+49 7031 463 2254


Latin America
+55 11 2125 0744


North America
+1 425 487 7000
800 285 5585 (toll free, US only)




Please visit www.philips.com/iDose4


                       © 2012 Koninklijke Philips Electronics N.V.
                       All rights are reserved.

                       Philips Healthcare reserves the right to make changes in specifications and/or to discontinue any product at any time without notice
                       or obligation and will not be liable for any consequences resulting from the use of this publication.

                       Printed in The Netherlands.
                       4522 962 83491 * JUN 2012

Más contenido relacionado

La actualidad más candente

Magnetic resonance angiography
Magnetic resonance angiographyMagnetic resonance angiography
Magnetic resonance angiographyRahman Ud Din
 
Recent Avancement of CT Scan
Recent Avancement of CT ScanRecent Avancement of CT Scan
Recent Avancement of CT ScanAmit Dutta Roy
 
Presentation1, radiological imaging of endometrial carcinoma.
Presentation1, radiological imaging of endometrial carcinoma.Presentation1, radiological imaging of endometrial carcinoma.
Presentation1, radiological imaging of endometrial carcinoma.Abdellah Nazeer
 
CT perfusion physics and its application in Neuroimaging
CT perfusion physics and its application in NeuroimagingCT perfusion physics and its application in Neuroimaging
CT perfusion physics and its application in NeuroimagingDr.Suhas Basavaiah
 
Magnetic Resonance Angiography and Venography
Magnetic Resonance Angiography and VenographyMagnetic Resonance Angiography and Venography
Magnetic Resonance Angiography and VenographyAnjan Dangal
 
Strain Elastography for Breast
Strain Elastography for BreastStrain Elastography for Breast
Strain Elastography for BreastAqib Umair
 
Copy of Mitsumori-CT angiography techniques
Copy of Mitsumori-CT angiography techniquesCopy of Mitsumori-CT angiography techniques
Copy of Mitsumori-CT angiography techniquesamin usmani
 
Recent advances in Mammography
Recent advances in MammographyRecent advances in Mammography
Recent advances in MammographyDr.Suhas Basavaiah
 
MDCT Principles and Applications- Avinesh Shrestha
MDCT Principles and Applications- Avinesh ShresthaMDCT Principles and Applications- Avinesh Shrestha
MDCT Principles and Applications- Avinesh ShresthaAvinesh Shrestha
 
Presentation1, radiological imaging of gastro intestinal stromal tumour(gist).
Presentation1, radiological imaging of gastro intestinal stromal tumour(gist).Presentation1, radiological imaging of gastro intestinal stromal tumour(gist).
Presentation1, radiological imaging of gastro intestinal stromal tumour(gist).Abdellah Nazeer
 

La actualidad más candente (20)

Magnetic resonance angiography
Magnetic resonance angiographyMagnetic resonance angiography
Magnetic resonance angiography
 
Recent Avancement of CT Scan
Recent Avancement of CT ScanRecent Avancement of CT Scan
Recent Avancement of CT Scan
 
Presentation1, radiological imaging of endometrial carcinoma.
Presentation1, radiological imaging of endometrial carcinoma.Presentation1, radiological imaging of endometrial carcinoma.
Presentation1, radiological imaging of endometrial carcinoma.
 
MR spectroscopy
MR spectroscopyMR spectroscopy
MR spectroscopy
 
CT perfusion physics and its application in Neuroimaging
CT perfusion physics and its application in NeuroimagingCT perfusion physics and its application in Neuroimaging
CT perfusion physics and its application in Neuroimaging
 
MRI artifacts
MRI artifactsMRI artifacts
MRI artifacts
 
Magnetic Resonance Angiography and Venography
Magnetic Resonance Angiography and VenographyMagnetic Resonance Angiography and Venography
Magnetic Resonance Angiography and Venography
 
Dual Energy CT
Dual Energy CTDual Energy CT
Dual Energy CT
 
Strain Elastography for Breast
Strain Elastography for BreastStrain Elastography for Breast
Strain Elastography for Breast
 
Copy of Mitsumori-CT angiography techniques
Copy of Mitsumori-CT angiography techniquesCopy of Mitsumori-CT angiography techniques
Copy of Mitsumori-CT angiography techniques
 
Mri artifacts
Mri artifactsMri artifacts
Mri artifacts
 
MRI BREAST PPT
MRI BREAST PPTMRI BREAST PPT
MRI BREAST PPT
 
CT fluoroscopy
CT fluoroscopyCT fluoroscopy
CT fluoroscopy
 
Recent advances in Mammography
Recent advances in MammographyRecent advances in Mammography
Recent advances in Mammography
 
MDCT Principles and Applications- Avinesh Shrestha
MDCT Principles and Applications- Avinesh ShresthaMDCT Principles and Applications- Avinesh Shrestha
MDCT Principles and Applications- Avinesh Shrestha
 
Coronary CT
Coronary CTCoronary CT
Coronary CT
 
MRS
MRS MRS
MRS
 
Mdct in cad
Mdct in cadMdct in cad
Mdct in cad
 
Ultrasound contrast agents
Ultrasound contrast agentsUltrasound contrast agents
Ultrasound contrast agents
 
Presentation1, radiological imaging of gastro intestinal stromal tumour(gist).
Presentation1, radiological imaging of gastro intestinal stromal tumour(gist).Presentation1, radiological imaging of gastro intestinal stromal tumour(gist).
Presentation1, radiological imaging of gastro intestinal stromal tumour(gist).
 

Similar a Ct idose brochure

Mri d stream brochure_final_16 nov 12
Mri d stream brochure_final_16 nov 12Mri d stream brochure_final_16 nov 12
Mri d stream brochure_final_16 nov 12Jhon Arriaga Cordova
 
Barco medical display systems
Barco medical display systems   Barco medical display systems
Barco medical display systems Santiago Scarsi
 
Ds2 High Bright Brochure (Email)
Ds2 High Bright Brochure (Email)Ds2 High Bright Brochure (Email)
Ds2 High Bright Brochure (Email)dynascan
 
Izinova display-solution 2013
Izinova  display-solution 2013Izinova  display-solution 2013
Izinova display-solution 2013openerp1
 
Magnetom C¡ 0.35 T - Siemens- OPEN
Magnetom C¡ 0.35 T - Siemens- OPENMagnetom C¡ 0.35 T - Siemens- OPEN
Magnetom C¡ 0.35 T - Siemens- OPENJhon Arriaga Cordova
 
Pellucid radproducts
Pellucid radproductsPellucid radproducts
Pellucid radproductsdieple88
 
Pellucid radproducts
Pellucid radproductsPellucid radproducts
Pellucid radproductsdieple88
 
Casio dpj product_brief_180214_white
Casio dpj product_brief_180214_whiteCasio dpj product_brief_180214_white
Casio dpj product_brief_180214_whiteDwiyono Agus Prasetyo
 
06 13sept 8313 9997-2-ed an adaptive (edit lafi)
06 13sept 8313 9997-2-ed an adaptive (edit lafi)06 13sept 8313 9997-2-ed an adaptive (edit lafi)
06 13sept 8313 9997-2-ed an adaptive (edit lafi)IAESIJEECS
 
High-Speed Single-Photon SPAD Camera
High-Speed Single-Photon SPAD CameraHigh-Speed Single-Photon SPAD Camera
High-Speed Single-Photon SPAD CameraFabrizio Guerrieri
 
Total exam2.product.sheet
Total exam2.product.sheetTotal exam2.product.sheet
Total exam2.product.sheetReyahwu
 
Total exam2.product.sheet
Total exam2.product.sheetTotal exam2.product.sheet
Total exam2.product.sheetReyahwu
 
Total exam2.product.sheet
Total exam2.product.sheetTotal exam2.product.sheet
Total exam2.product.sheetReyahwu
 

Similar a Ct idose brochure (20)

Mri d stream brochure_final_16 nov 12
Mri d stream brochure_final_16 nov 12Mri d stream brochure_final_16 nov 12
Mri d stream brochure_final_16 nov 12
 
iPad for (tele)radiology, a critical appraisal
iPad for (tele)radiology, a critical appraisaliPad for (tele)radiology, a critical appraisal
iPad for (tele)radiology, a critical appraisal
 
Dukane 8420 dlp projector
Dukane 8420 dlp projectorDukane 8420 dlp projector
Dukane 8420 dlp projector
 
Dukane 8241 dlp projector
Dukane 8241 dlp projectorDukane 8241 dlp projector
Dukane 8241 dlp projector
 
Dukane 8421 DLP projector
Dukane 8421 DLP  projectorDukane 8421 DLP  projector
Dukane 8421 DLP projector
 
Barco medical display systems
Barco medical display systems   Barco medical display systems
Barco medical display systems
 
Ds6707 hc
Ds6707 hcDs6707 hc
Ds6707 hc
 
Ds2 High Bright Brochure (Email)
Ds2 High Bright Brochure (Email)Ds2 High Bright Brochure (Email)
Ds2 High Bright Brochure (Email)
 
Izinova display-solution 2013
Izinova  display-solution 2013Izinova  display-solution 2013
Izinova display-solution 2013
 
Magnetom C¡ 0.35 T - Siemens- OPEN
Magnetom C¡ 0.35 T - Siemens- OPENMagnetom C¡ 0.35 T - Siemens- OPEN
Magnetom C¡ 0.35 T - Siemens- OPEN
 
Pellucid radproducts
Pellucid radproductsPellucid radproducts
Pellucid radproducts
 
Pellucid radproducts
Pellucid radproductsPellucid radproducts
Pellucid radproducts
 
Casio dpj product_brief_180214_white
Casio dpj product_brief_180214_whiteCasio dpj product_brief_180214_white
Casio dpj product_brief_180214_white
 
06 13sept 8313 9997-2-ed an adaptive (edit lafi)
06 13sept 8313 9997-2-ed an adaptive (edit lafi)06 13sept 8313 9997-2-ed an adaptive (edit lafi)
06 13sept 8313 9997-2-ed an adaptive (edit lafi)
 
High-Speed Single-Photon SPAD Camera
High-Speed Single-Photon SPAD CameraHigh-Speed Single-Photon SPAD Camera
High-Speed Single-Photon SPAD Camera
 
GLS-1000
GLS-1000GLS-1000
GLS-1000
 
Embedded vision system
Embedded vision systemEmbedded vision system
Embedded vision system
 
Total exam2.product.sheet
Total exam2.product.sheetTotal exam2.product.sheet
Total exam2.product.sheet
 
Total exam2.product.sheet
Total exam2.product.sheetTotal exam2.product.sheet
Total exam2.product.sheet
 
Total exam2.product.sheet
Total exam2.product.sheetTotal exam2.product.sheet
Total exam2.product.sheet
 

Más de Jhon Arriaga Cordova (20)

Resonancia no ecoplanar en colesteatoma.pptx
Resonancia no ecoplanar en colesteatoma.pptxResonancia no ecoplanar en colesteatoma.pptx
Resonancia no ecoplanar en colesteatoma.pptx
 
Oído.pptx
Oído.pptxOído.pptx
Oído.pptx
 
Toshiba Visions 23
Toshiba Visions 23Toshiba Visions 23
Toshiba Visions 23
 
FieldStrength 49
FieldStrength 49FieldStrength 49
FieldStrength 49
 
FieldStrength 50 advanced neuro
FieldStrength 50 advanced neuroFieldStrength 50 advanced neuro
FieldStrength 50 advanced neuro
 
Ct somatom sessions-33
Ct somatom sessions-33Ct somatom sessions-33
Ct somatom sessions-33
 
Somatom sessions 32
Somatom sessions 32Somatom sessions 32
Somatom sessions 32
 
Somatom sessions 31
Somatom sessions 31Somatom sessions 31
Somatom sessions 31
 
Somatom sessions 30
Somatom sessions 30Somatom sessions 30
Somatom sessions 30
 
Somatom sessions 26
Somatom sessions 26Somatom sessions 26
Somatom sessions 26
 
Somatom sessions 25
Somatom sessions 25Somatom sessions 25
Somatom sessions 25
 
Somatom sessions 24
Somatom sessions 24Somatom sessions 24
Somatom sessions 24
 
Somatom session 29
Somatom session 29Somatom session 29
Somatom session 29
 
Somatom session 29
Somatom session 29Somatom session 29
Somatom session 29
 
Somatom session 28
Somatom session 28Somatom session 28
Somatom session 28
 
Somatom session 27
Somatom session 27Somatom session 27
Somatom session 27
 
Somatom session 27
Somatom session 27Somatom session 27
Somatom session 27
 
Neurography Supplement to Issue 50
Neurography Supplement to Issue 50Neurography Supplement to Issue 50
Neurography Supplement to Issue 50
 
ISMRM Edition - Issue 49
ISMRM Edition - Issue 49ISMRM Edition - Issue 49
ISMRM Edition - Issue 49
 
Pediatric Imaging - Issue 47
Pediatric Imaging - Issue 47Pediatric Imaging - Issue 47
Pediatric Imaging - Issue 47
 

Ct idose brochure

  • 1. You control the dial Philips CT iDose4 iterative reconstruction technique
  • 2. The results you want Philips iDose4 is an iterative reconstruction technique that gives you control of the dial so you can personalize image quality based on your patients’ needs at low dose. When used in combination with the advanced technologies of the iCT, Ingenuity, and Brilliance CT scanner families, this provides a unique approach to managing important factors in patient care – low energy, low dose, and low injected contrast imaging. Which setting do you need? Increase resolution with low dose 120 kVp; 150 mAs CTDIvol – 10.2 mGy DLP – 187 mGy xcm Effective dose – 0.6 mSv* Improve spatial resolution at a lower dose Significantly Reduce dose improve spatial even further resolution at without the the same dose plastic look Significantly improve resolution Manage dose without sacrificing 120 kVp; 100 mAs image quality CTDIvol – 6.5 mGy 80 kVp; 10 mAs DLP – 136 mGy xcm CTDIvol (32cm) – 0.21 mGy Effective dose – 2 mSv* DLP – 2.9 mGy xcm Effective dose – 0.16 mSv* 2 *AAPM technical report 96
  • 3. at the speeds you need If it’s fast, it’s Philips A majority of reference protocols are reconstructed in under 60 seconds with iDose4 iterative reconstruction technique. With iDose4, reconstruction is achieved in seconds rather than minutes. This is due to the innovative RapidView IR reconstruction engine. Designed to suppor t iDose4, this proprietary technology allows for this iterative reconstruction technique to be used routinely in inpatient, outpatient, and emergency care settings. With the combination of iDose4 and RapidView IR, the majority of all factory protocols are reconstructed in 60 seconds or less. The design seamlessly integrates into your CT department, and provides you the look and feel of conventional higher dose images without long processing times. RapidView IR Philips Proprietary, state-of-the-art parallel architecture Philips high performance computational core is equivalent to the power of hundreds of computers. 119 cm reconstructed in 49.5 seconds 3
  • 4. The iDose 4 Clinical integration Patient focus Improve economic value and collaboration • Personalize image quality • High throughput • Improve image quality* based on patients’ needs • Streamline workflow • Preserve “natural” at low dose • Easy to adopt into existing appearance • anage dose without M standard of care • Robust artifact prevention sacrificing image quality • Availability across majority • Fast reconstruction speed • Applicable to majority of product portfolio of clinical conditions What is Imaging 2.0? Web 2.0 described the evolution of the web from being data-driven to user-centric, redefining the way people connect, share, and use the Internet. Imaging 2.0 is doing the same, bringing a new world of possibilities for radiology. It is about integration and collaboration, and new levels of patient focus and care that can help clinicians achieve what was unimaginable just a few short years ago. 4 *mproved image quality as defined by improvements in spatial resolution and/or noise reduction as measured in phantom studies. I
  • 5. advantage The evolution of reconstruction Generation 4 – Advanced iterative reconstruction technique Preserved “natural” appearance I Robust artifact prevention I Improved image quality * 3 3 erat ion Generation 3 – Basic iterative reconstruction technique Artifact reduction Gen Generation 2 – Image based filtering/denoising 2 2 ion Removal of some image noise erat Gen Generation 1 – Standard reconstruction without iDose4 1 1 ion Fast erat Gen Philips iDose4 (4th-generation reconstruction) provides key clinical benefits** Improved image quality* Up to 57% improvement in spatial resolution Preserved natural image appearance Less than 5% noise-power-spectrum shift Robust artifact prevention Low signal streak correction Protocol integration Axial, helical, ECG- and pulmonary-gated, dual-energy, and perfusion Standard, high, and ultrahigh resolution 5122 , 7682 , and 10242 image matrix sizes Flexible 7 distinct, user-selectable levels that support image quality personalization based on your clinical needs Fast With RapidView IR, reconstruction is achieved in seconds rather than minutes. The majority of reference protocols are reconstructed in under 1 minute. “I think that iDose4 is going to be the future for everyone in the sense that I can honestly think of no reason why you would not use it in your practice if you have it available.” Barry D. Daly, MD University of Maryland Medical Center, Baltimore, MD * Improved image quality as defined by improvements in spatial resolution and/or noise reduction as measured in phantom studies. ** Results may vary based on scanner model. 5
  • 6. Scanner benefits Pulmonary imaging with increased resolution Bariatric imaging with improved image quality* High resolution High resolution iDose 4: OFF iDose4: Level 7 iDose 4: OFF iDose4: Level 3 Neuro imaging with increased contrast-to-noise Improve image quality* and preserve “natural” appearance Orthopedic imaging with iDose 4: OFF iDose4: Level 3 reduced artifacts from implants Coronary imaging with increased resolution iDose 4: OFF O-MAR + O-MAR + iDose 4: OFF iDose4: Level 7 iDose 4: OFF iDose4: Level 7 6 *Improved image quality as defined by improvements in spatial resolution and/or noise reduction.
  • 7. enabled by iDose 4 Manage dose without sacrificing image quality Routine chest X-ray 80 kVp, 10 mAs, 80 kVp, 10 mAs, 0.06 mSv 0.2 mGy, 0.08 mSv 0.2 mGy, 0.08 mSv iDose 4: OFF iDose4: Level 3 Quantitative imaging at low-dose CBV CBF MTT TTP Robust artifact 80 kVp 125 mAs iDose 4: OFF iDose 4: OFF prevention and noise reduction. iDose4: Level 7 80 kVp 31 mAs iDose 4: Level 7 Fast and seamless 80 kVp 31 mAs iDose 4: OFF integration. iDose 4: OFF Low-Dose Simulation Trauma imaging Low energy imaging when combined with reduced artifacts with advanced scanner technologies 120 kVp, 100 mAs, 80 kVp, 130 mAs, 6.6 mGy, 9.6 mSv 2.7 mGy, 2.8 mSv iDose 4: OFF iDose4: Level 4 Nov 2009 April 2010 iDose 4: OFF iDose4: Level 4 7
  • 8. Manage dose without sacrificing image quality Low dose acquisitions are often associated with streak artifacts. Basic iterative reconstruction techniques may provide some incremental benefit in reducing these artifacts; however, iDose4 – an advanced iterative reconstruction technique – prevents these artifacts and improves image quality** in this Step Shoot Cardiac scan. Scan parameters • 100 kVp • 17 mAs • Coverage – 18.7 cm • iDose4 – Level 4 • CTDIvol – 0.8 mGy • DLP – 15.7 mGy xcm • Effective dose – 0.2 mSv* • Reconstruction time – 32 s (415 images) • Scanner – iCT Pediatric patients undergoing frequent follow-up imaging benefit from low-energy, low-dose and high image quality. This high- heart-rate, sub-mSv follow-up study was performed on a non-sedated patient using the iCT with iDose4, resulting in low signal streak correction and high image quality. Scan parameters • 80 kVp • 100 mAs • Coverage – 10.3 cm • Heart rate – 143 bpm • Scan time – 6.6 s • iDose4 – Level 3 • CTDIvol – 2.2 mGy • DLP – 22.6 mGy xcm • Reconstruction time – 12 s • Scanner – iCT *AAPM technical report 96 8 **Improved image quality as defined by improvements in spatial resolution and/or noise reduction.
  • 9. Quantitative imaging below background radiation dose Perfusion scans may result in relatively high patient dose due to repeated scanning of the same structure over time. In this case, low-dose scanner technologies combined with iDose4 helped manage dose without sacrificing image quality. Scan parameters • 80 kVp • 31 mAs** • Coverage – 8 cm • iDose4 – Level 7 • CTDIvol – 1.2 mGy x 40 • DLP – 9.6 mGy xcm x 40 • Effective dose – 0.8 mSv* • Scanner – iCT The primary rationale to move from retrospective to prospective ECG-gated cardiac CTA acquisitions was to enable low-dose acquisitions at the expense of losing functional information. Low-energy scanner technologies combined with iDose4 resulted in full cardiac assessment at dose levels equivalent to back- ground radiation without sacrificing image quality. Scan parameters • 100 kVp • 273 mAs • Coverage – 16.5 cm • Scan time – 6.3 s • Resolution – 12.3 lp/cm • iDose4 – Level 4 • CTDIvol – 10.5 mGy • DLP – 223.2 mGy xcm • Effective dose – 3.1 mSv* • Reconstruction time – 91 s (1,155 images) • Scanner – iCT *AAPM technical report 96 **Simulated from 125 mAs acquisition 9
  • 10. Improve resolution of cardiac imaging Limited resolution on cardiac CTA acquisitions can hinder visualization of the coronary lumen in the presence of heavy calcified plaque or coronary stents. This can be particularly challenging when balancing the low-dose needs of the patient. iDose 4 significantly improves spatial resolution at low dose. Scan parameters • 80 kVp • 195 mAs • Coverage – 13.5 cm • Scan time – 4.5 s • iDose4 – Level 4 • CTDIvol – 4.2 mGy • DLP – 56.7 mGy xcm • Effective dose – 0.8 mSv* • Scanner – iCT Leveraging the low-dose capabilities of Step Shoot Cardiac with the high-resolution capabilities of iDose4, the study provides improved visualization. Scan parameters • 120 kVp • 200 mAs • Coverage – 12.5 cm • Scan time – 7.9 s • Heart rate – 51 bpm • iDose4 – Level 6 • CTDIvol – 16.8 mGy • DLP – 210.0 mGy xcm • Effective dose – 2.9 mSv* • Scanner – Ingenuity CT 10 *AAPM technical report 96
  • 11. Improve resolution and artifact prevention in orthopedic imaging CT imaging of patients with orthopedic implants often results in loss of anatomical information due to a combination of artifacts. O-MAR reduces artifacts caused by large orthopedic implants and iDose4 improves image quality. Scan parameters • 140 kVp • 145 mAs/slice • Coverage – 25.6 cm • O-MAR – on • iDose4 – Level 4 • Scanner – Brilliance 64 The noise-resolution correlation on standard reconstruction techniques previously required trade-offs between dose and resolution. Breaking this connection, iDose4 provides high-resolution with low-noise in this low-dose study. Scan parameters • 120 kVp • 100 mAs • Coverage – 15.3 cm • Focal spot resolution – high • Image matrix – 768 x 768 • iDose4 – Level 3 • CTDIvol – 6.5 mGy • DLP – 136 mGy xcm • Effective dose – 2 mSv* • Scanner – Ingenuity CT *AAPM technical report 96 11
  • 12. Improve resolution in oncology imaging In radiation oncology, clinical needs are particularly focused towards accurate treatment planning, which ties into the need to have increased image quality. The increased contrast-to-noise in this study helps improve visualization. Scan parameters • 120 kVp • 500 mAs • Coverage – 24 cm • iDose4 – Level 1 • Scanner – Brilliance CT Big Bore In oncology patients, improved image quality plays an important part in accurate treatment planning. The image quality benefits of iDose4 extend across a majority of the CT product portfolio, to include the Brilliance CT 16-slice. Scan parameters • 120 kVp • 200 mAs/slice • Coverage – 34.2 cm • iDose4 – Level 4 • Scanner – Brilliance 16 12
  • 13. Improve image quality in noisy acquisitions Bariatric imaging is prone to increased image noise and artifacts (streaks and bias). Standard reconstruction and basic iterative reconstruction techniques are particularly limited in addressing artifacts. iDose4 advanced iterative reconstruction technique helps reduce noise and prevent artifacts. Scan parameters • 120 kVp • 190 mAs • Coverage – 56.5 cm • Scan time – 6.3 s • iDose4 – Level 7 • Scanner – iCT Quantitative analysis of iodine enhancement was performed on the dual-energy data in delayed phase images relative to liver parenchyma. One lesion demonstrated washout in the delayed enhancement Increasing Iodine phase, subsequent to early enhancement in the Concentration arterial phase.The other lesion demonstrated central hypoenhancement in the delayed phase and other phases.The use of the iDose4 iterative reconstruction technique reduced image noise and allowed greater detail to be seen in the quantitative analysis. HU 80 kVp 3 Scan parameters • 80/140 kVp 2 • 460/90 mAs • Collimation – 64 x 0.625 mm 1 • iDose4 – Level 4 • DLP – 75.2 mGy xcm HU 140 kVp • CTDIvol – 9.4 x2 mGy • Effective dose – 1.1 mSv* • Scanner - iCT *AAPM technical report 96 13
  • 14. The results you want, at the speeds you need Low-energy imaging allows for increased iodinated contrast resolution at low dose; however, low-energy techniques often result in increased artifacts in larger patients. Ingenuity CT with iDose 4 provides robust artifact prevention in low-energy acquisitions, even in large patients. Scan parameters • 80 kVp • 135 mAs avg. • Coverage – 59.5 cm • Scan time – 10.3 s • iDose4 – Level 6 • CTDIvol – 2.6 mGy • DLP – 169.5 mGy xcm • Effective dose – 2.5 mSv* • Reconstruction time – 148 s (1,181 images) • Scanner – Ingenuity CT Emergency and trauma imaging are highly demanding in terms of artifacts that may impact image quality and time to diagnosis. iDose4 reduces artifacts in images. This can be helpful in imaging patients who cannot lift their arms due to positioning requirements, weakness, or injury. Scan parameters • 120 kVp • 39 mAs • Coverage – 157.7 cm • Scan time – 50.4 s • Focal spot resolution – high • iDose4 – Level 5 • CTDIvol – 2.6 mGy • DLP – 428 mGy xcm • Effective dose – 6.4 mSv* • Scanner – Ingenuity CT 14 *AAPM technical report 96
  • 15. On the SmartPath with you We understand how critical it is to elevate quality and efficiency in your daily work routine. And Philips SmartPath is your way to obtain access to the latest innovations throughout the cycle of your ownership. We are committed to bringing the benefits of iterative reconstruction technique to all. This is why we designed an iDose4 upgrade to put you at the forefront of clinical innovations and workflow efficiencies, and expand the clinical capabilities of your current system. iDose4 is available across the iCT, Ingenuity, and Brilliance CT families iCT TVI • iCT • iCT SP Ingenuity CT • Ingenuity Core128 • Ingenuity Core Brilliance CT 64-channel with Essence technology • Brilliance CT 64-channel Brilliance CT 40-channel • Brilliance CT Big Bore * * Brilliance CT 16-slice*† • Brilliance CT 10-slice* • Brilliance CT 6-slice*† Philips SmartPath provides you easy access to solutions and innovations for the full life of your computed tomography system, so you can boost your clinical and operational potential and achieve your organizational goals. Optimize your system’s Enhance your equipment Transform your investment performance both now with regular technology at the end of your system’s life and in the future with regular upgrades, and take by transitioning seamlessly and ongoing updates, including advantage of the newest to a next-generation solution functionality improvements features and capabilities. or refurbished option. Optimize and remote technical support. Enhance Transform * May require prerequisite upgrade for iDose4 eligibility. Air-cooled scanners only. Please contact your local Philips representative for availability and prerequisite requirements. † 8 MHU X-ray tube configuration prerequisite. 15
  • 16. Philips Healthcare is part of Royal Philips Electronics How to reach us www.philips.com/healthcare healthcare@philips.com Asia +49 7031 463 2254 Europe, Middle East, Africa +49 7031 463 2254 Latin America +55 11 2125 0744 North America +1 425 487 7000 800 285 5585 (toll free, US only) Please visit www.philips.com/iDose4 © 2012 Koninklijke Philips Electronics N.V. All rights are reserved. Philips Healthcare reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. Printed in The Netherlands. 4522 962 83491 * JUN 2012