GeoVision : Intergation Solutions : GV-NVR and Access Control with PTZ preset on camera
1. How to set PTZ Preset Function with GV-AS200 Controller
Article ID: GV-33-08-07-10
Release Date: 2008/7/10
Applied to
GV-AS200 Controller
Summary
GV-AS200 Controller can work in conjunction with the PTZ camera to perform preset
functions on two doors. In this application, one PTZ camera is connected to both outputs of
Door B and Door D on the GV-AS200 module. When Door A is opened, the signal of Wiegand
A will be transmitted to Wiegand B (Door B) and it will trigger the PTZ camera view moving to
Door A. When Door C is opened, the signal of Wiegand C will be transmitted to Wiegand D
(Door D) and it will trigger the PTZ camera view moving to Door C.
Requirements
4-door modules: GV-AS200-4 or GV-AS200-4E
To Connect a PTZ to GV-AS200 Controller
1. The work mode of GV-AS200 Controller must be set to One Way Control. By default,
the work mode is One Way Control. If the default setting has been changed, use
GV-ASKeypad to modify it.
GeoVision Inc. 1 Revision Date: 2008/7/21
2. 2. Connect the card reader to the Wiegand A inputs. Then connect the D0 and D1 pins of
Wiegand A with the two same pins of Wiegand B, as illustrated below.
GND
BZ
RL
GL
D1
D0
12V
GND
BZ
RL
GL
D1
D0
12V
3. Connect the Door + pin of Door B outputs to the Input 1 pin of PTZ. Then connect the
Urgent 1 pin of Door B outputs to the Ground pin of PTZ, as illustrated below.
Please note don’t connect any power to the Door B outputs.
4. Set the Door Relay Switch of Door B to NO.
GeoVision Inc. 2 Revision Date: 2008/7/21
3. 5. Connect the card reader to the Wiegand C inputs. Then connect the D0 and D1 pins of
Wiegand C with the two same pins of Wiegand D, as illustrated below.
GV-Reader
Wiegand D Wiegand C
6. Connect the Door + pin of Door D outputs to the Input 2 pin of PTZ. Then connect the
Urgent 1 pin of Door D outputs to the Ground pin of PTZ, as illustrated below.
Please note don’t connect any power to the Door D outputs.
7. Set the Door Relay Switch of Door D to NO.
GeoVision Inc. 3 Revision Date: 2008/7/21
4. 8. It is required to allow the accessibility of Door B and Door D even though only Door A
and Door C are used for entry and exit.
GeoVision Inc. 4 Revision Date: 2008/7/21