3. Simple Solution Structured Cabling Solution for IBS/DC Fiber/Copper Systems Intelligent Infrastructure Management System Intelligent Power Management System Pre-terminated Systems Wireless AP Systems Rack /Tray Solution
5. Entrance Room (ER) & Telecommunication Room (TR) Main Distribution Area (MDA) & Horizontal Distribution Area (HDA) Next floor Zone Distribution Area (ZDA) Equipment Distribution Area (EDA) Data Center Solutions Copper (C7,6A,6Plus) 1 Fiber(OM3,4) 2 Simple Fast Net™ 3 4 Simple GXC™ Patching 4 Simple Fast-Net™ MPO 5 1 Simple Closet™ (HDR, Cooling Manager) 6 2 7 10 Simple Paths™ 7 3 Simple View™ IPM 6 8 5 8 Simple View™ IIM 9 9 Simple Fast-Point™ 10
6.
7. To optimum performance, all LS Cat. 5e, 6, 6A, 7 Cable, Jacks are 100% tested, delivering a cost effective media for high-bandwidth IBS / Data Center applications
13. Simple Solution Copper Solution ( Cat 6A ) Cable diameter 8mm (Patent Pending) Int’l Standard Certified (UL etc) W17.6, H20.6, D31mm Int’l Standard Certified Minimized Alien-talk between near ports Convenient wiring with slim structure High credibility Labeling, Jack, Patch cord, Panel suitable for Data center Complied with TIA/EIA 568B.2-10, ISO11801 2nd Class E, TIA 942, Fcc Part 68 and KCC High Margin on Transmission Performance Complied with TIA/EIA 568B.2-10, ISO11801 2nd Class E and TIA 942 PVC(CMX/CM/CMR/CMP), LSZH(CMX) Improved Alien X-talk & Reduced cable diameter with ‘H’ type filler Patent Pending
14.
15. Simple Solution Copper Solution ( Fast-Net TM ) ②pre-terminated panel & module ④ equipment cord ① six bundle patch cord ① Channel ③ six bundle cable
16. Simple Solution Copper Solution ( Fast-Net TM ) ① Patching & Cord Arrangement ② IDC Connecting (Terminate) ③ Test ④ Labeling ⑤ Pull Cabling & Bundle ① ② ③ ④ ⑤ Maximum 8 timesTime Saving
94. Updating the database is a burden for the IT manager. 70% 30% Time to failure point acknowledgement Time to revoery MTTR(Network) 20% 80% Time to failure point acknowledgement Time to recovery MTTR(Cabling)
95.
96. Security & Risk Manangement : Asset Tracking, real time identification
97. Operation Efficiency : Capacity planning, Reduce Mean Time to Repair(MTTR), MACs control
114. Previous Present Simple Solution Historical Methods of Monitoring & Control - Today 21st Century Data Centers require more Power and Cooling - Power supply is limited and expensive - Maximization of expensive resources to minimize waste, reduce costs - Maximize of Payload operations, preventative Maintenance, zero downtime, Maximization of operations - Todays Data Centers cannot function without IIM solutions. - Todays Data Centers are Designed and Categoried in tiers to quantify the degree of Security and resilience built into the Data Centre. - Monitoring was Local only at point of entry into Data room i.e. Power Distribution boards - Temperature was measured via BMS, remote from the Payload equipment. - Load values / cabinet was occasionally recorded manually with a hand held CT. - No accurate records, real time measuring, identification of Temperature / Power hot spots. - No Monitoring, No Management, Not a problem, energy was cheap and plenty, Power foot print per sq M typically was 1-3 kWatt, easily obtained
119. Simple Solution Why Monitor ? Capacity planning - typically users run out of power or cooling before anything else Need to know where energy is being used. Need to know where energy is wasted Business planning & technology refresh - Understand why and where energy performance is poor, how to improve it & build business cases Physical & Network security – human error a major cause of failures (audit trails) ‘Real time’ monitoring and alerting – early warning maximises time available to respond Need to know where energy demand is going to shortly exceed capacity. Eliminate downtime caused by undiagnosed environmental disturbances Government Legistration : The Carbon Emission Commitment
121. Simple Solution Humidity Sensor Temperature Sensor Remote console management Keypad/HID Card Reader Electronic Door Lock Monitored and controlled power strips LCD Status Display In Line Power Monitoring 37
209. Simple Solution Enable Cable lengthMinimization Easy Additional cabling adding No interfere air flowing from under floor on cold asile Before After
233. Simple Solution Operating room Data Center LS Wi-Fi Access Point LS Wi-Fi Access Point Back bone LS PoE Switch LS PoE Switch Data+Power
234. Simple Solution LS Wi-Fi AP has applied IEEE 802.11n draft 2.0, providing users with high bandwidth and wide coverage when using Volp Phone, laptop, and PDA. Its application of IEEE 802.3af PoE also helps provide data and power by LAN cable, making it easier to install. 802.11b/g/n 1 port 10/100Base-Tx wth PoE PD 2x2 MIMO(Multi-Input, Multi-Output) WEP64/128bit, 802.1x, ESSID WMM(WiFi Multimedia), WPS(WiFi Protect Setup) NAT/Bridge mode DHCP Server, Client Web-based Management, SNMPv1/2
235. Simple Solution Wireless Acess Point ( Simple Fast-Point TM ) Layer 2 swithch which IEEE802.3 Ethernet based data communication and IEEE802.3af standard based Power Source works simultaneously. supports VLAN, RSTP, QoS which optimizes traffic flow and bandwidth usage Reduce additional cost to provide power to the eqipment 24 port 10/100Base-Tx with PoE PSE for subscriber 2 port 10/100/1000Base-T or SFP for uplink Non-blocking switching, Store and forward structure VLAN, Multicast, STP/RSTP, Packet Classification, QoS function Web-based, SNMP control function. 19” Rack mountBoxtype