9.
10.
11. Purified water Spec as per IP Conform to the test Chloride NMT 0.1 ppm Heavy Metals (2.4.8) Conform to the test 0.5ml of 0.01M EDTA Ca and Mg NMT 0.2 ppm Ammonium NMT 5.1 µS/cm (EP) Conductivity ( at 25° C ) NMT 0.2 ppm Nitrates Conform to the test Acidity or Alkalinity Clear, Colourless, Odourless and tasteless Nature Limit Parameter
12. Purified water Spec as per IP Conform to the test Oxid. Substances < 0.25 EU/ml Endotoxins (2.6.14) NMT 80 cfu/ml (alert limit) NMT 100 cfu/ml Bioburden (2.6.12) NMT 10ppb Aluminium NMT 0.001% Res. on Evaporation Conform to the test Sulphates Limit Parameter
13.
14.
15. Purified water Spec USP/EP Conform to the test Oxid. Substances Conform to the test Acidity or Alkalinity NMT 0.1 ppm Heavy Metals (2.4.8) Conform to the test NO2 NMT 0.2 ppm NO3 < 0.5 ppm TOC NMT 2.1 µS/cm (USP) NMT 5.1 µS/cm (EP) Conductivity ( at 25° C ) 5 - 7 pH Clear, Colourless, Odourless Nature Limit Parameter
16. Purified water Spec USP/EP < 0.5 ppm TOC < 0.25 EU/ml Endotoxins (2.6.14) NMT 80 cfu/ml (alert limit) NMT 100 cfu/ml Bioburden (2.6.12) NMT 0.001% Res. on Evaporation Conform to the test Ca / Mg NMT 0.2 ppm Ammonium Conform to the test Sulphate Conform to the test Chloride Limit Parameter
17.
18.
19.
20. Typical water storage and distribution schematic Water must be kept circulating Spray ball Cartridge filter 1 µm Air break to drain Outlets Hygienic pump Optional in-line filter 0,2 µm UV light Feed Water from DI or RO Heat Exchanger Ozone Generator Hydrophobic air filter & burst disc