Production Process of
Wotech Heat Pumps

Wotech Electrical Limited
PART A COMPONENTS INSPECTION
1. Titanium heat exchanger ( for pool heat pump)
Refrigerant water leakage check:
Connect the heat exchanger with water pipes and charge water pressure
up to 4 bar to see if water leaks from the PVC shell. 100% check on every
heat exchanger with 4 bar water pressure and 6 bar as random check on
some pieces.
P.S.: Water pressure for normal pool system is 2 bar only.

2/35
A round green QC passed sticker will be put on the heat exchanger to show
this is QC passed.
A green square sticker will put on the heat exchanger to show this passed 6
bar random check.
Flow switches been checked before they are installed on the heat
exchangers so green stickers are also on each flow switch here.

3/35
Refrigerant circuit leakage check:
Titanium heat exchangers are kept at high pressure of nitrogen in the
titanium coil inside for 48 hours to check refrigerant circuit leakage before
being assembled, this is 100% check.

4/35
•

After 48 hours workers will unscrew the gas valve to check if any gas
pressure inside the titanium coil to find the leaks. 100% check. Those fail will
be rejected to suppliers.

5/35
2.Evaporator

Weld the evaporator with the
refrigerant distributing copper
pipes (one side blocked)

Charge 30 bar gas pressure
(nitrogen) into the
evaporator and drop it into
the water to find leaks.
100% check.

6/35
3. Tube in shell heat exchanger

•

Connect each shell in tube
heat exchanger with water
pipes and charge 6 bar water
pressure to see if any leaks on
copper pipes inside the heat
exchanger. 100% check.

7/35
4.Pressure gauges

•
•
•

Pressure gauges are treated the same
for 72 hours with notes marking pressure status. Leakage can be
easily found during the process. 100% check.
Those which pass the test will be put green QC passed stickers on
the back.

8/35
5.Mother board and control display

•

All mother boards and control
displays will be connected with
electricity, they would be tested
under big range of electricity
fluctuation– 177 volt to 264 volt for
72 hours. Electronic components
with poor quality will easily fail in this
test. 100% check.

9/35
6. Fan motor

•

All fan motors are to be checked
by this equipment, it shows main
phase current, vice phase current
and etc, make sure if the
specification meets Wotech
requirement. 100% check.

10/35
7. Flow switch

•

Flow switches will be connected with water and power,
set certain flow to see if they function. 100% check.

11/35
Part B Preproduction
1. Subassembly of electronic system

12/35
•

Electronic system is built QC will check the wiring connections.
Different bulbs standing for compressor, water pump, fan motor,
4-way valve and etc will be on only when the wiring is correct.
QC will also check if the program is written per customer’s
request. 100% check.

13/35
2. Fan motor subassembly

14/35
2. Copper pipe work subassembly

Workers are welding copper pipe work
Carefully.

Copper pipe work subassembly ready
for production.

15/35
Part C ,Production
1. Building refrigeration system
When all important components are checked and QC passed they would
be built on the heat pumps. first step is to build refrigeration system,
compressor, evaporator, condenser and copper pipe work.

16/35
During soldering nitrogen is blown into the pipe work to avoid soldering
residues dropping into the tubing and stuck refrigerant system.

17/35
2. First leakage check on refrigeration system

Refrigeration system will be charged with nitrogen when bubble testing
starts. Soap-subs will be brushed on all the soldering points to check if any
leakage. This is the first time leakage check on refrigeration on production
line.
High pressure and low pressure switch will be also checked if they function
or not.

18/35
3. Vacuum refrigeration system

After bubble testing system will be vacuumed for 25 minutes before being
charged refrigerant.

19/35
4. Refrigerant charge

Refrigerant charge equipment will first check the heat pump
refrigeration system is vacuumed well enough to reach the set
Standard before it charges refrigerant , or would give alarm and
stop charging.

20/35
Refrigerant charge equipment is calibrated
frequently by official measuring bureau and
marked with green stickers on all the measur
-ing components.
There are 2 different refrigerant charge system
inside R407c and R410a.

21/35
•

•

There are scale indication calibrators which
enable it to to make sure at different ambient
temperature the right volume is charged.
To make sure the refrigerant always work well
after charging the refrigerant by this
equipment the first unit of same model of the
order will be checked the volume by electronic
weight. If the volume is correct production will
be proceeded on the rest heat pump.

22/35
5. Second leakage check on refrigerant system

It is necessary to blow away the residues of refrigerant on the heat pump
Before the second leakage check on refrigerant system.
All the soldering points and all possible weak points will be checked by gas
Sniffer equipment.

23/35
Freon leak detector can find
leakage of 2g/year on the
Refrigerant system. It alarms
When freon leak is found above
2 g/year.

24/35
6. Connect electronic system to refrigerant system

Wirings between mother board and
components for compressor, fan motor,
4-way valve, high & low pressure
switches, sensors and etc must be
connected properly.

Wirings and insulations look neat
and tidy .

25/35
7. Electrical safety items testing
Each heat pump must be checked with electrical
safety items and standards:
A.
B.
C.
D.

Grounding: within 5 seconds <100 mΩ
Withstand voltage: within 3 seconds 1800V, <5mA
Insulation: 500 V, >2 MΩ
Leakage: within 2 seconds 234V <0.75mA

26/35
8. Performance testing

Each heat pump will have to be tested 30 mins for
heating and 30 mins for cooling
(if there is cooling mode) . Water flow will
Be fixed, sensors will be installed on important
positions to check if heat pump performs as
designed. All test results will be marked on the
unique product ID check list. Those which does not
perform well enough will be taken off from
production line for investigation.

27/35
9. Dry the heat pump

After performance testing water in the heat exchanger will be dried and blow
away.
28/35
10. Third time leakage check on refrigeration system

After performance testing refrigerant will run through the system . If any leaks it
Would be much easier to find now.

29/35
11. Heat pump second start-up

Before packed in carton each heat pump will be connected with power to see
If all wirings are still in good contact. It is aware that when the heat pump is
Dried out the water, wirings is got loose and in bad contact.

30/35
12. Cleaning , labeling and accessory bag, packaging

31/35
13. Heat pump ready for loading

32/35
14. Product traceability

Each heat pump has its own product ID
check list with serial nr. on right upper
corner during the whole production. All
the process are printed and to be
marked if they are properly done. After
the heat pump is packed QC will keep
all these check list for filing and future
reference.
Serial nr. are also marked on side
panel, fan motor, capacitor and etc, for
this we can always trace them back.

33/35
Part D ,Quality control
There is a product ID check list with each unit
marking down all the process of the unit, each step
will have 3 persons checked and marked on the sheet
as a record, if problems found during production
remarks would be written on the sheet and products
sent back to be reworked and solve the problem until
everything is ok.

We have technical operation instruction
at each stage of the production line to
instruction workers how to meet our
requirements of quality and workmanship.

34/35
The End
Thank you.

Prepared by: Stella Yau

Date: Oct. 27th.2012

Más contenido relacionado

La actualidad más candente

Genie ghr heated pressure regulator datasheet
Genie ghr heated pressure regulator datasheetGenie ghr heated pressure regulator datasheet
Genie ghr heated pressure regulator datasheet
a1-cbiss
 
Data sheet g52 m print version
Data sheet g52 m print versionData sheet g52 m print version
Data sheet g52 m print version
a1-cbiss
 

La actualidad más candente (20)

Eta constant temperature and humidity test chamber
Eta constant temperature and humidity test chamberEta constant temperature and humidity test chamber
Eta constant temperature and humidity test chamber
 
SeptiTech STAAR Denitrification Wastewater Presentation
SeptiTech STAAR Denitrification Wastewater PresentationSeptiTech STAAR Denitrification Wastewater Presentation
SeptiTech STAAR Denitrification Wastewater Presentation
 
Vapour pressure-model-1354 atac
Vapour pressure-model-1354 atacVapour pressure-model-1354 atac
Vapour pressure-model-1354 atac
 
Genie ghr heated pressure regulator datasheet
Genie ghr heated pressure regulator datasheetGenie ghr heated pressure regulator datasheet
Genie ghr heated pressure regulator datasheet
 
Cold chamber
Cold chamberCold chamber
Cold chamber
 
About us
About usAbout us
About us
 
Data sheet g52 m print version
Data sheet g52 m print versionData sheet g52 m print version
Data sheet g52 m print version
 
Sodium Analyzer for Industrial Applications
Sodium Analyzer for Industrial ApplicationsSodium Analyzer for Industrial Applications
Sodium Analyzer for Industrial Applications
 
Rowland Hall Hvac Retrofit
Rowland Hall Hvac RetrofitRowland Hall Hvac Retrofit
Rowland Hall Hvac Retrofit
 
Ec91 Intrinsically Safe Oxygen Analyser
Ec91 Intrinsically Safe Oxygen AnalyserEc91 Intrinsically Safe Oxygen Analyser
Ec91 Intrinsically Safe Oxygen Analyser
 
AccuThermo AW 810 Rapid Thermal Anneal Equipment
AccuThermo AW 810 Rapid Thermal Anneal EquipmentAccuThermo AW 810 Rapid Thermal Anneal Equipment
AccuThermo AW 810 Rapid Thermal Anneal Equipment
 
Gas analyzers
Gas analyzersGas analyzers
Gas analyzers
 
Fox Commercial Services PMA Presentation
Fox Commercial Services PMA PresentationFox Commercial Services PMA Presentation
Fox Commercial Services PMA Presentation
 
Boiler operation technical information
Boiler operation   technical informationBoiler operation   technical information
Boiler operation technical information
 
Medical Gases Training.
Medical Gases Training.Medical Gases Training.
Medical Gases Training.
 
Product testing and compliance edited - MCE 2014
Product testing and compliance edited - MCE 2014Product testing and compliance edited - MCE 2014
Product testing and compliance edited - MCE 2014
 
Combustion Analyzer to Add Extra Layer of Safety to Burner Management System
Combustion Analyzer to Add Extra Layer of Safety to Burner Management SystemCombustion Analyzer to Add Extra Layer of Safety to Burner Management System
Combustion Analyzer to Add Extra Layer of Safety to Burner Management System
 
Validation of hvac
Validation of hvacValidation of hvac
Validation of hvac
 
Air Accessories - ELGi USA
Air Accessories - ELGi USAAir Accessories - ELGi USA
Air Accessories - ELGi USA
 
AccuThermo AW 820V Vacuum Rapid Thermal Anneal Equipment
AccuThermo AW 820V Vacuum  Rapid Thermal Anneal EquipmentAccuThermo AW 820V Vacuum  Rapid Thermal Anneal Equipment
AccuThermo AW 820V Vacuum Rapid Thermal Anneal Equipment
 

Similar a Production Process of Wotech Heat Pump Products

Training on OJT of Boiler Operation00.pdf
Training on OJT of Boiler Operation00.pdfTraining on OJT of Boiler Operation00.pdf
Training on OJT of Boiler Operation00.pdf
Madan Karki
 
Caleffi International NV - Brochure Solar
 Caleffi International NV - Brochure Solar Caleffi International NV - Brochure Solar
Caleffi International NV - Brochure Solar
Architectura
 

Similar a Production Process of Wotech Heat Pump Products (20)

Replacement Parts Industries (RPI) Everything You Ever Wanted to Know About S...
Replacement Parts Industries (RPI) Everything You Ever Wanted to Know About S...Replacement Parts Industries (RPI) Everything You Ever Wanted to Know About S...
Replacement Parts Industries (RPI) Everything You Ever Wanted to Know About S...
 
Training on OJT of Boiler Operation00.pdf
Training on OJT of Boiler Operation00.pdfTraining on OJT of Boiler Operation00.pdf
Training on OJT of Boiler Operation00.pdf
 
MET 214 Module 6
MET 214 Module 6MET 214 Module 6
MET 214 Module 6
 
Understanding three plate molds and hot runner system
Understanding   three plate  molds and hot runner systemUnderstanding   three plate  molds and hot runner system
Understanding three plate molds and hot runner system
 
TEMPERATURE TRANSMITTER TEMPE TEMPERATURE TRANSMITTER
TEMPERATURE TRANSMITTER TEMPE TEMPERATURE TRANSMITTERTEMPERATURE TRANSMITTER TEMPE TEMPERATURE TRANSMITTER
TEMPERATURE TRANSMITTER TEMPE TEMPERATURE TRANSMITTER
 
TEMPERATURE TRANSMITTER_2023 TEMPERATURE TRANSMITTER_2023
TEMPERATURE TRANSMITTER_2023 TEMPERATURE TRANSMITTER_2023TEMPERATURE TRANSMITTER_2023 TEMPERATURE TRANSMITTER_2023
TEMPERATURE TRANSMITTER_2023 TEMPERATURE TRANSMITTER_2023
 
Caleffi International NV - Brochure Solar
 Caleffi International NV - Brochure Solar Caleffi International NV - Brochure Solar
Caleffi International NV - Brochure Solar
 
The Money-Saving Survival Guide: AC, Heating, and Air Quality
The Money-Saving Survival Guide: AC, Heating, and Air QualityThe Money-Saving Survival Guide: AC, Heating, and Air Quality
The Money-Saving Survival Guide: AC, Heating, and Air Quality
 
Training of hot runner system [bharat jiyani]
Training  of  hot runner  system [bharat jiyani]Training  of  hot runner  system [bharat jiyani]
Training of hot runner system [bharat jiyani]
 
motorised valves
motorised valvesmotorised valves
motorised valves
 
Hydraulic flushing rig ppt
Hydraulic flushing rig pptHydraulic flushing rig ppt
Hydraulic flushing rig ppt
 
SP118 Solar Working Station 2014 New Manual
SP118 Solar Working Station 2014 New ManualSP118 Solar Working Station 2014 New Manual
SP118 Solar Working Station 2014 New Manual
 
Api682
Api682Api682
Api682
 
DMA Direct Mercury Analyzer
DMA  Direct Mercury AnalyzerDMA  Direct Mercury Analyzer
DMA Direct Mercury Analyzer
 
Manual filtro pentair
Manual filtro pentair Manual filtro pentair
Manual filtro pentair
 
Steam Boiler Sequence Of Operation
Steam Boiler Sequence Of OperationSteam Boiler Sequence Of Operation
Steam Boiler Sequence Of Operation
 
Fuel gas system of gas production
Fuel gas system of gas productionFuel gas system of gas production
Fuel gas system of gas production
 
Environmental test chamber
Environmental test chamberEnvironmental test chamber
Environmental test chamber
 
Mac 050
Mac 050Mac 050
Mac 050
 
Waterex softener installation manual
Waterex softener installation manualWaterex softener installation manual
Waterex softener installation manual
 

Último

FULL ENJOY Call Girls In Majnu Ka Tilla, Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Majnu Ka Tilla, Delhi Contact Us 8377877756FULL ENJOY Call Girls In Majnu Ka Tilla, Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Majnu Ka Tilla, Delhi Contact Us 8377877756
dollysharma2066
 
Call Girls From Pari Chowk Greater Noida ❤️8448577510 ⊹Best Escorts Service I...
Call Girls From Pari Chowk Greater Noida ❤️8448577510 ⊹Best Escorts Service I...Call Girls From Pari Chowk Greater Noida ❤️8448577510 ⊹Best Escorts Service I...
Call Girls From Pari Chowk Greater Noida ❤️8448577510 ⊹Best Escorts Service I...
lizamodels9
 
Russian Call Girls In Rajiv Chowk Gurgaon ❤️8448577510 ⊹Best Escorts Service ...
Russian Call Girls In Rajiv Chowk Gurgaon ❤️8448577510 ⊹Best Escorts Service ...Russian Call Girls In Rajiv Chowk Gurgaon ❤️8448577510 ⊹Best Escorts Service ...
Russian Call Girls In Rajiv Chowk Gurgaon ❤️8448577510 ⊹Best Escorts Service ...
lizamodels9
 
Call Girls Kengeri Satellite Town Just Call 👗 7737669865 👗 Top Class Call Gir...
Call Girls Kengeri Satellite Town Just Call 👗 7737669865 👗 Top Class Call Gir...Call Girls Kengeri Satellite Town Just Call 👗 7737669865 👗 Top Class Call Gir...
Call Girls Kengeri Satellite Town Just Call 👗 7737669865 👗 Top Class Call Gir...
amitlee9823
 
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
dollysharma2066
 

Último (20)

Business Model Canvas (BMC)- A new venture concept
Business Model Canvas (BMC)-  A new venture conceptBusiness Model Canvas (BMC)-  A new venture concept
Business Model Canvas (BMC)- A new venture concept
 
Falcon Invoice Discounting: The best investment platform in india for investors
Falcon Invoice Discounting: The best investment platform in india for investorsFalcon Invoice Discounting: The best investment platform in india for investors
Falcon Invoice Discounting: The best investment platform in india for investors
 
FULL ENJOY Call Girls In Majnu Ka Tilla, Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Majnu Ka Tilla, Delhi Contact Us 8377877756FULL ENJOY Call Girls In Majnu Ka Tilla, Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Majnu Ka Tilla, Delhi Contact Us 8377877756
 
Marel Q1 2024 Investor Presentation from May 8, 2024
Marel Q1 2024 Investor Presentation from May 8, 2024Marel Q1 2024 Investor Presentation from May 8, 2024
Marel Q1 2024 Investor Presentation from May 8, 2024
 
Call Girls From Pari Chowk Greater Noida ❤️8448577510 ⊹Best Escorts Service I...
Call Girls From Pari Chowk Greater Noida ❤️8448577510 ⊹Best Escorts Service I...Call Girls From Pari Chowk Greater Noida ❤️8448577510 ⊹Best Escorts Service I...
Call Girls From Pari Chowk Greater Noida ❤️8448577510 ⊹Best Escorts Service I...
 
Russian Call Girls In Rajiv Chowk Gurgaon ❤️8448577510 ⊹Best Escorts Service ...
Russian Call Girls In Rajiv Chowk Gurgaon ❤️8448577510 ⊹Best Escorts Service ...Russian Call Girls In Rajiv Chowk Gurgaon ❤️8448577510 ⊹Best Escorts Service ...
Russian Call Girls In Rajiv Chowk Gurgaon ❤️8448577510 ⊹Best Escorts Service ...
 
How to Get Started in Social Media for Art League City
How to Get Started in Social Media for Art League CityHow to Get Started in Social Media for Art League City
How to Get Started in Social Media for Art League City
 
It will be International Nurses' Day on 12 May
It will be International Nurses' Day on 12 MayIt will be International Nurses' Day on 12 May
It will be International Nurses' Day on 12 May
 
Famous Olympic Siblings from the 21st Century
Famous Olympic Siblings from the 21st CenturyFamous Olympic Siblings from the 21st Century
Famous Olympic Siblings from the 21st Century
 
Falcon Invoice Discounting: Empowering Your Business Growth
Falcon Invoice Discounting: Empowering Your Business GrowthFalcon Invoice Discounting: Empowering Your Business Growth
Falcon Invoice Discounting: Empowering Your Business Growth
 
Cheap Rate Call Girls In Noida Sector 62 Metro 959961乂3876
Cheap Rate Call Girls In Noida Sector 62 Metro 959961乂3876Cheap Rate Call Girls In Noida Sector 62 Metro 959961乂3876
Cheap Rate Call Girls In Noida Sector 62 Metro 959961乂3876
 
Mysore Call Girls 8617370543 WhatsApp Number 24x7 Best Services
Mysore Call Girls 8617370543 WhatsApp Number 24x7 Best ServicesMysore Call Girls 8617370543 WhatsApp Number 24x7 Best Services
Mysore Call Girls 8617370543 WhatsApp Number 24x7 Best Services
 
Phases of Negotiation .pptx
 Phases of Negotiation .pptx Phases of Negotiation .pptx
Phases of Negotiation .pptx
 
Call Girls Kengeri Satellite Town Just Call 👗 7737669865 👗 Top Class Call Gir...
Call Girls Kengeri Satellite Town Just Call 👗 7737669865 👗 Top Class Call Gir...Call Girls Kengeri Satellite Town Just Call 👗 7737669865 👗 Top Class Call Gir...
Call Girls Kengeri Satellite Town Just Call 👗 7737669865 👗 Top Class Call Gir...
 
The Path to Product Excellence: Avoiding Common Pitfalls and Enhancing Commun...
The Path to Product Excellence: Avoiding Common Pitfalls and Enhancing Commun...The Path to Product Excellence: Avoiding Common Pitfalls and Enhancing Commun...
The Path to Product Excellence: Avoiding Common Pitfalls and Enhancing Commun...
 
Katrina Personal Brand Project and portfolio 1
Katrina Personal Brand Project and portfolio 1Katrina Personal Brand Project and portfolio 1
Katrina Personal Brand Project and portfolio 1
 
RSA Conference Exhibitor List 2024 - Exhibitors Data
RSA Conference Exhibitor List 2024 - Exhibitors DataRSA Conference Exhibitor List 2024 - Exhibitors Data
RSA Conference Exhibitor List 2024 - Exhibitors Data
 
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
 
Eluru Call Girls Service ☎ ️93326-06886 ❤️‍🔥 Enjoy 24/7 Escort Service
Eluru Call Girls Service ☎ ️93326-06886 ❤️‍🔥 Enjoy 24/7 Escort ServiceEluru Call Girls Service ☎ ️93326-06886 ❤️‍🔥 Enjoy 24/7 Escort Service
Eluru Call Girls Service ☎ ️93326-06886 ❤️‍🔥 Enjoy 24/7 Escort Service
 
Falcon Invoice Discounting platform in india
Falcon Invoice Discounting platform in indiaFalcon Invoice Discounting platform in india
Falcon Invoice Discounting platform in india
 

Production Process of Wotech Heat Pump Products

  • 1. Production Process of Wotech Heat Pumps Wotech Electrical Limited
  • 2. PART A COMPONENTS INSPECTION 1. Titanium heat exchanger ( for pool heat pump) Refrigerant water leakage check: Connect the heat exchanger with water pipes and charge water pressure up to 4 bar to see if water leaks from the PVC shell. 100% check on every heat exchanger with 4 bar water pressure and 6 bar as random check on some pieces. P.S.: Water pressure for normal pool system is 2 bar only. 2/35
  • 3. A round green QC passed sticker will be put on the heat exchanger to show this is QC passed. A green square sticker will put on the heat exchanger to show this passed 6 bar random check. Flow switches been checked before they are installed on the heat exchangers so green stickers are also on each flow switch here. 3/35
  • 4. Refrigerant circuit leakage check: Titanium heat exchangers are kept at high pressure of nitrogen in the titanium coil inside for 48 hours to check refrigerant circuit leakage before being assembled, this is 100% check. 4/35
  • 5. • After 48 hours workers will unscrew the gas valve to check if any gas pressure inside the titanium coil to find the leaks. 100% check. Those fail will be rejected to suppliers. 5/35
  • 6. 2.Evaporator Weld the evaporator with the refrigerant distributing copper pipes (one side blocked) Charge 30 bar gas pressure (nitrogen) into the evaporator and drop it into the water to find leaks. 100% check. 6/35
  • 7. 3. Tube in shell heat exchanger • Connect each shell in tube heat exchanger with water pipes and charge 6 bar water pressure to see if any leaks on copper pipes inside the heat exchanger. 100% check. 7/35
  • 8. 4.Pressure gauges • • • Pressure gauges are treated the same for 72 hours with notes marking pressure status. Leakage can be easily found during the process. 100% check. Those which pass the test will be put green QC passed stickers on the back. 8/35
  • 9. 5.Mother board and control display • All mother boards and control displays will be connected with electricity, they would be tested under big range of electricity fluctuation– 177 volt to 264 volt for 72 hours. Electronic components with poor quality will easily fail in this test. 100% check. 9/35
  • 10. 6. Fan motor • All fan motors are to be checked by this equipment, it shows main phase current, vice phase current and etc, make sure if the specification meets Wotech requirement. 100% check. 10/35
  • 11. 7. Flow switch • Flow switches will be connected with water and power, set certain flow to see if they function. 100% check. 11/35
  • 12. Part B Preproduction 1. Subassembly of electronic system 12/35
  • 13. • Electronic system is built QC will check the wiring connections. Different bulbs standing for compressor, water pump, fan motor, 4-way valve and etc will be on only when the wiring is correct. QC will also check if the program is written per customer’s request. 100% check. 13/35
  • 14. 2. Fan motor subassembly 14/35
  • 15. 2. Copper pipe work subassembly Workers are welding copper pipe work Carefully. Copper pipe work subassembly ready for production. 15/35
  • 16. Part C ,Production 1. Building refrigeration system When all important components are checked and QC passed they would be built on the heat pumps. first step is to build refrigeration system, compressor, evaporator, condenser and copper pipe work. 16/35
  • 17. During soldering nitrogen is blown into the pipe work to avoid soldering residues dropping into the tubing and stuck refrigerant system. 17/35
  • 18. 2. First leakage check on refrigeration system Refrigeration system will be charged with nitrogen when bubble testing starts. Soap-subs will be brushed on all the soldering points to check if any leakage. This is the first time leakage check on refrigeration on production line. High pressure and low pressure switch will be also checked if they function or not. 18/35
  • 19. 3. Vacuum refrigeration system After bubble testing system will be vacuumed for 25 minutes before being charged refrigerant. 19/35
  • 20. 4. Refrigerant charge Refrigerant charge equipment will first check the heat pump refrigeration system is vacuumed well enough to reach the set Standard before it charges refrigerant , or would give alarm and stop charging. 20/35
  • 21. Refrigerant charge equipment is calibrated frequently by official measuring bureau and marked with green stickers on all the measur -ing components. There are 2 different refrigerant charge system inside R407c and R410a. 21/35
  • 22. • • There are scale indication calibrators which enable it to to make sure at different ambient temperature the right volume is charged. To make sure the refrigerant always work well after charging the refrigerant by this equipment the first unit of same model of the order will be checked the volume by electronic weight. If the volume is correct production will be proceeded on the rest heat pump. 22/35
  • 23. 5. Second leakage check on refrigerant system It is necessary to blow away the residues of refrigerant on the heat pump Before the second leakage check on refrigerant system. All the soldering points and all possible weak points will be checked by gas Sniffer equipment. 23/35
  • 24. Freon leak detector can find leakage of 2g/year on the Refrigerant system. It alarms When freon leak is found above 2 g/year. 24/35
  • 25. 6. Connect electronic system to refrigerant system Wirings between mother board and components for compressor, fan motor, 4-way valve, high & low pressure switches, sensors and etc must be connected properly. Wirings and insulations look neat and tidy . 25/35
  • 26. 7. Electrical safety items testing Each heat pump must be checked with electrical safety items and standards: A. B. C. D. Grounding: within 5 seconds <100 mΩ Withstand voltage: within 3 seconds 1800V, <5mA Insulation: 500 V, >2 MΩ Leakage: within 2 seconds 234V <0.75mA 26/35
  • 27. 8. Performance testing Each heat pump will have to be tested 30 mins for heating and 30 mins for cooling (if there is cooling mode) . Water flow will Be fixed, sensors will be installed on important positions to check if heat pump performs as designed. All test results will be marked on the unique product ID check list. Those which does not perform well enough will be taken off from production line for investigation. 27/35
  • 28. 9. Dry the heat pump After performance testing water in the heat exchanger will be dried and blow away. 28/35
  • 29. 10. Third time leakage check on refrigeration system After performance testing refrigerant will run through the system . If any leaks it Would be much easier to find now. 29/35
  • 30. 11. Heat pump second start-up Before packed in carton each heat pump will be connected with power to see If all wirings are still in good contact. It is aware that when the heat pump is Dried out the water, wirings is got loose and in bad contact. 30/35
  • 31. 12. Cleaning , labeling and accessory bag, packaging 31/35
  • 32. 13. Heat pump ready for loading 32/35
  • 33. 14. Product traceability Each heat pump has its own product ID check list with serial nr. on right upper corner during the whole production. All the process are printed and to be marked if they are properly done. After the heat pump is packed QC will keep all these check list for filing and future reference. Serial nr. are also marked on side panel, fan motor, capacitor and etc, for this we can always trace them back. 33/35
  • 34. Part D ,Quality control There is a product ID check list with each unit marking down all the process of the unit, each step will have 3 persons checked and marked on the sheet as a record, if problems found during production remarks would be written on the sheet and products sent back to be reworked and solve the problem until everything is ok. We have technical operation instruction at each stage of the production line to instruction workers how to meet our requirements of quality and workmanship. 34/35
  • 35. The End Thank you. Prepared by: Stella Yau Date: Oct. 27th.2012