FULL NIGHT — 9999894380 Call Girls In Delhi | Delhi
M3 Lecture 10 timber roof structure answer
1. JOB NO: TAKER OFF:
JOB TITLE:
ELEMENT: Timber Roof Structure DATE:
Timber Roof Structure Hip
Wall Plates
2/ 13.50 27.00 75mm x 50mm hardwood timber Rafter = 4.90 , Width = 4.50
2/ 6.70 13.40 Grade B timber plates
40.40
Hip
Rafter
Ceiling Joists 4.500
No of Rafter & Ceiling Joists Hip^2 = (4.9)^2 + (4.5)^2
Width Hip^2 = 24.01 + 20.25
0.610 ) 15.50 Hip = 6.65
25
No of Ceiling Joists = 25 +1 = 26 Hip
4/ 6.65 26.60 100mm x 50mm hardwood timber
Grade B pitched roof members.
Ceiling Joists
26/ 6.70 174.20 50mm x 50mm hardwood timber
Grade B pitched roof members.
Rafters
26/2/ 4.90 254.80 100mm x 50mm hardwood timber
Grade B pitched roof members.
Ridges
1/ 6.85 6.85 100mm x 75mm hardwood timber
Grade B pitched roof members.
Struts
26/ 1.90 49.40 100mm x 50mm hardwood timber
26/2/ 1.30 67.60 Grade B pitched roof members.
26/2/ 0.60 31.20
26/2/ 1.55 80.60
26/2/ 1.20 62.40
291.20
page /
2. JOB NO: TAKER OFF:
JOB TITLE:
ELEMENT:Timber Roof Structure DATE:
Timber Roof Covering Fascia Boards
Roof Tiles
2/ 15.50 31.00 220mm x 20mm wide hardwood
2/ 4.90 420mm x 330mm concrete 2/ 8.60 17.20 Grade B timber fascia board
15.50 151.90 tiles to 100mm head lap laid at 30° 48.20 fixed to timber structure.
pitched, each tile nailed every
alternate course on 50 X30 mm
Grade B timber battens.
Painting for fascia boards
2/ 4.90 A layer of double sides aluminium Girth
15.50 151.90 foil insulation paper laid on straining 2/ 0.220 0.440
wires & lapped 150mm at joists. 0.020
0.460
48.20 Knotting, stopping, 1 coat primer
0.46 22.17 1 undercoat and 2 coat of gloss
Ridge Tiles paint finishes to general surface of
1/ 6.85 6.85 Extra Over concrete tiles timber over 300mm
for 250mm width ridge tiles bedded and
painted and pointed in cement and
sand (1:3) mortar.
Hip Tiles Timber Roof Drainage
4/ 6.65 26.60 Extra Over concrete tiles Gutter (Q.5.1)
for 250mm width hip tiles bedded and 2/ 16.20 32.40 100mm diameter half round u.p.v.c
painted and pointed in cement and 2/ 8.60 17.20 gutter fixed to timber fascia board
sand (1:3) mortar. 49.60 with brackets at 600mm centers.
Three Way Apex Gutter Fittings (Q.5.3))
2 2 Extra Over concrete tiles for 250mm 4 4 Extra Over 100mm diameter
width three way apex bedded and half round u.p.v.c gutter for 90 º bend
painted and pointed in cement and
sand (1:3) mortar. 4 4 Extra Over 100mm diameter
half round u.p.v.c gutter
outlet for water down pipe.
4 4 Approved u.p.v.c balloon grating
fixed to top of outlet
Rainwater Down pipe
Length
1.100
2.400
3.500
Rainwater Down pipe (Q.8.1)
4/ 3.50 14.00 100mm u.p.v.c. rainwater down pipe
including all fittings & bracket
fixed to brickwall
4/ 1.10 4.40 100mm u.p.v.c. rainwater down pipe
including all fittings bedded
under the concrete slab
Rainwater Down pipe fitting (Q.8.6)
4/ 4 16 Exra over 100mm u.p.v.c bends for
rain water down pipe
page /