PRÁTICA NECTAS 1641-1651

ACESSAR O NECTAS

USUÁRIO – ADMIN
SENHA – ADMIN

BELL > DISABLE

BACKUP

1641 – SM SALVAR:
EQUIPAMENT CONFIGURATION
CONNECTION CONFIGURATION
LOCAL CONFIGURATION
ROUTING TABLES

1651 – SM SALVAR:
EQUIPAMENT CONFIGURATION
CONNECTION CONFIGURATION WITH FULL MATRIX
CONNECTION CONFIGURATION WITH VC4 MATRIX
DROP SHELF CONNECTION CONFIGURATION
LOCAL CONFIGURATION
ROUTING TABLES

(SE HOUVER DÚVIDA SALVAR TUDO)

OBS: ONDE TIVER DROP SHELF NÃO PRECISA SALVAR (1641 SMD), NO 1651
VAI ESTAR A MATRIX FULL OU A VC4.
DROP SHELF É UM SUB BASTIDOR DO 1641 ASSOCIADO AO 1651. O 1651 É
EQUIPADO ATÉ 1 STM1, COM O DROP SHELF ESSA CAPACIDADE É AMPLIADA
COM 3 STM1, FICANDO ATÉ 4 STM1.

EXECUTANDO BACKUP

ABRIR ELEMENTO DE REDE (DUPLO CLICK)
EQUIPAMENT CONFIGURATION >
FILE > RECIVE
DIGITAR DADOS DA ESTAÇÃO > OK
CONNECTION CONFIGURATION
FILE > RECIVE
DIGITAR DADOS DA ESTAÇÃO > OK
LOCAL CONFIGURATION
FILE > RECIVE
DIGITAR DADOS DA ESTAÇÃO > OK
ROUTING TABLES
FILE > RECIVE
DIGITAR DADOS DA ESTAÇÃO > OK

PARA SALVAR EM OUTRA PASTA

IR ATÉ A PASTA C: ALCATEL /1641 SM 27 OU 1651 SM 25 (COPIA PARA A PSTA
DA ESTAÇÃO SEM AUTERAR O ARQUIVO)

TROCAR SMEC


  1        2                        DIP SWITCH
 ON       OFF                    POSIÇÃO NORMAL
 OFF      ON           POSIÇÃO LIMPEZA DE BANCO DE DADOS
 OFF      OFF     RECUPERAR LOCAL CONFIGURATION (NE, OS ADRESS,
                                 LAPD, ETHERNET).
  ON      ON               RETAURAR O BANCO DE DADOS
  ON      OFF                    POSIÇÃO NORMAL


PASSOS:

PASSO 1 - RETIRAR A SMEC DIP 1 OFF DIP 2 ON – INSERIR A PLACA E
AGUARDA O LED ABN ACENDER. (O BANCO FOI LIMPO).
PASSO 2 - RETIRAR A SMEC DIP I OFF DIP 2 ON – INSERIR A PLACA, AGUARDA
O LED ABN ACENDER.(FOI RECUPERADO LOCAL CONFIGURATION).
PASSO 3- RETIRAR A SMEC DIP I ON DIP 2 ON – INSERIR A PLACA, AGUARDA
O LED ABN ACENDER.(ENVIAR AS TABELAS DE BACKUP AO NE).
PASSO 4 - RETIRAR A SMEC DIP I ON DIP 2 OFF – INSERIR A PLACA, AGUARDA
O LED ABN ACENDER.

PARA RESTORE

FILE SEND (SELECIONA ARQUIVO DA ESTAÇÃO E CLICA OK)

SEQUENCIA DE TABELAS:
CONNECTION CONFIGURATION
EQUIPMENT CONFIGURATION
LOCAL CONFIGURATION
ROUTING TABLES
DEMAIS TABELAS


INSERIR NA GERÊNCIA

LAPD
ETHERNET CONFIG (Só para cne´s)
1- LAPD
ABRIR ELEMENTO DE REDE (DUPLO CLICK)
CLICA EM LAPD CONFIGURATION >AGRR STMI E1 (USER)
                               >AGRR STM1W1 (NETWORK)
LOCAL CONFIGURATION > YES
                        > NETWORK
TABLES > MS LAPD CONFIGURATION
E1 > W1
2 – ETH > YES
        > FALSE (L2 ONLY)
3 – OS ADRESS
INSERIR NSAP DA GERÊNCIA
NO            NO
4 – NE ADRESS (LOCAL CONFIGURATION)
INSERIR NSAP E 7.1 (ADRESS DO NE)
SISTEM ID (EX 002060222222)
7.1 = 8
FILE > SAVE > FILE > SEND.
OBS-SE HOUVER MUDANÇA DO NSAP, O SISTEMA EXECUTA REBOOT. É
NECESSÁRIO CONECTAR NOVAMENTE.



ACESSO REMOTO

1 – DECLARAR NO MEU ELEMENTO DE REDE, OS NSAP´S QUE QUERO VER
REMOTAMENTE.

LOCAL / CONFIG > R-ECT
YES (MARCA)
DIGITA NSAP E 7.1 ADRESS DOS NE´S REMOTOS.
CLICA EM NEXT PARA CRIAR OUTRO NE.
FILE > SAVE > FILE > SEND.

FECHAR O NECTAS

2 – MENU INICIAR

>PROGRAMAS > ALCATEL > NETWORK CONFIG
>NETWORK CONFIGURATION
>NETWORK > CREATE > DEFAUT
                  > NETWORK NAME (GENERAL)
                  > CREATE

3 – ABRIR PAINT BRUSH PARA CRIAR UM FUNDO, QUE SERÁ INSERIDO NA
REDE (GENERAL).
FAÇA UM “COPY” NO PAINT BRUSH E UM “MAP > PASTE” NO MAPA
GENERAL.
4 – CRIAR UM NE GENÉRICO QUALQUER
EQUIPAMENT > CREATE > ME (0) > SECONDARY ADRESS (5) > CREATE

BOTÃO ESQUERDO > LOCATE EQUIPAMENT > LOCALIZE

5 – EDITAR WIN INI
IR A C: / WINT / WIN.INI E EDITAR COM OS DADOS:
[ PEX ]
COMPEX=COM1:
PEXLOAD=
12TimRetrasmiis=20sec
12TimPolling=4sec
12TimResponse=5sec
12Retry=1
NETCFG_RECT=YES
NETCFG_NETWORK=C:/NETWORK/REDE/
TXTPATH=C:NETWORK/REDE/TXTFILE/
NETWORK_RF=REDE
NETPATH=C:/NETWORK/REDE/NETFILE/
WMFPATH=C:/NETWORK/REDE/WMFILE/
NETWORK=REDE
OBS-CASO O NOME DO MAPA SEJA GENERAL, SUBSTITUIR A PALAVRA REDE
POR GENERAL.

6 – ABRIR O NECTAS

VIW > NETWORK (Aparecerá todos os elementos criados)
OBS-de 2 a 5 é a configuração do Laptop

VIW > SUB NETWORK / EQUIPAMENTS ( duplo click)
ALARMS E STATUS > OK


CROSS CONEXÃO

CRIANDO CIRCUITO DE 2 MB
ABRE O NE (duplo click)
CONNECTION CONFIGURATION > OK
FILE > RECIVE > SELECIONA ESTAÇÃO > OK (Salva)
TABLE > PAYLOAD STRUTURE AND SIGNAL LABEL > OK
TABLE > TU-12´S ALLOCATION FOR 21X2M/SCDMA TRIBUTARY > OK
EQUIPA O TRIBUTÁRIO
EQUIPA O TU12 (CRIAR CORRESPONDENCIA COM O LADO REMOTO)
EQUIPA O MODE (D / I BIDI UNP E OU W (E OU W DE ACORDO COM O
PROJETO, UM LADO E O OUTRO W)).
FILE > SEND > SAVE > SEND

OBS= NO LADO REMOTO DEVE SE FAZER O MESMO PROCESSO
1641, 1651, 1664 SÓ DOIS AGREGADOS.

FAZER LOOP 2MB

ABRE O NE (duplo click)
CLICA ALARMES, STATUS AND REMOTE CONTROLS > OK
CLICA LOGIC > T2M 1 (PLACA DE TRIBUTÁRIO PRINCIPAL)
CLICA NO TRIBUTÁRIO
CLICA REMOTE_CONTROL
CURRENT DISPLAY
ENABLE INT LOOP 2M (PARA DENTRO DO EQUIPAMENTO) LOOP REMOTO
ENABLE LINE LOOP 2M (PARA FORA DO EQUIPAMENTO) – INSTRUMENTO


FAZER LOOP DE AGREGADO

ABRE O NE (duplo click)
CLICA ALARMES, STATUS AND REMOTE CONTROLS > OK
CLICA LOGIC > AG-1 E1 (IN) PLACA DE AGREGADO PRINCIPAL
CLICA REMOTE_CONTROL
CURRENT DISPLAY
ENABLE INT LOOP (PARA DENTRO DO EQUIPAMENTO) LOOP REMOTO
ENABLE LINE LOOP (PARA FORA DO EQUIPAMENTO) – INSTRUMENTO




FORÇAR LASER

ABRE O NE (duplo click)
CLICA FILE > RECIVE > SAVE > TABLE > OPTICAL SAFETY CONFIGURATION
SELECIONA A OPÇÃO DESEJADA:
ALS DISABLE SET TX ON (LASER FORÇADO)
ALS DISABLE SET TX OFF (LASER DESLIGADO)
ALS DISABLE (CONDIÇÃO NORMAL DE LASER)
FILE SEND > OK (CONFERIR A ESTAÇÃO)
OBS: PARA DESFAZER REPETE O PROCESSO.
FORÇAR COMUTAÇÃO

ABRE O NE (duplo click)
CLICA FILE > RECIVE > SAVE >
ALARMS, STATUS AND REMOTE CONTROLS >
> CLICA LOGIC > CLICA NA PLACA CORRESPONDENTE ( EX AGGR MAIN)
> REMOTE CONTROL > CURRENT DISPLAY >
> MANUAL ACTIVE STM1 AGGR

OBS: PARA RETIRAR A COMUTAÇÃO FORÇADA
> SELECIONA A PLACA > REMOTE CONTROL > CURRENT DISPLAY >
> CLEAR FORCE ACTIVE STM1 AGG

* COMUTAÇÃO MANUAL: VERIFICA O OUTRO RECURSO ANTES DE COMUTAR
* COMUTAÇÃO FORÇADA NÃO VERIFICA O OUTRO RECURSO ANTES DE
COMUTAR.

SINCRONISMO

CRU MAIN

ABRE O NE (duplo click)
FILE > RECIVE > SAVE >
EQUIPMENT CONFIGURATION > OK
FILE > RECIVE … AGUARDA
NOMEIA A ESTAÇÃO > OK
TABLE > SYNCRHRONIZATION: ADM TYPE & TRIBUTARY
CONFIGURATION > OK
MARCA SINGLE ADM
SE QUIZER 2M SELECIONA TRIB 1,2,OU 3 E A PORTA = 1° PORTA
CLICA EM OK

TABLE > SYNCRHRONIZATION PRIORITY LIST CONFIGURATION > OK

Fazer sair por T4 o sinal que tiver entrando na entrada de sincronismo externo T3.
Normalmente T4=T0.
Referência 1- 2 MHz = GPS (melhor relógio, qualidade G811)
Priority de 1 a 6 (1 mais prioritário)
Squelch , bloqueia o sinal de relógio se não for melhor ou igual a referência indicada.

OBS: O sistema procura trabalhar com a melhor qualidade, depois avalia a prioridade.
Sequencia de qualidade: G811, G812t, G812l, G813.

SSM ALGORITHM ENABLE = MARCAR
(É QUEM DEFINE PARA OLHAR PRIMEIRO A QUALIDADE) > CLICA EM OK

TABLE > SYNCRHRONIZATION: SSM VALUE CONFIGURATION
INFORMA A QUALIDADE: EXTRATED PARA RX ( E1 OU W1)
                     INSERTED PARA TX (E1 OU W1)
CLICA EM OK


SOFTWARE MISMASH

CRU MAIN ALARMANDO (PODE SE COMUTAR A SMEC)

VERSÃO DE UNIDADES
ABRE O NE (duplo click)
CLICA FILE > RECIVE > SAVE >
ALARMS, STATUS AND REMOTE CONTROLS >
SW VERSION > CLICA NA PLACA

PARA VER PACOTE DE SOFTWARE

ABRE O NE
> SOFTWARE DOWNLOAD > (VERIFICAR VERSÕES, PACOTE SMEC,
DOWNLOADS)
> NE IDENTIFICATION > (MOSTRA 2 PACOTES DE SOFTWARES DENTRO DA
SMEC EX 1641 V2.7.37)
> DESCRIPTOR FILE > (VERIFICA AS VERSÕES DAS UNIDADES EX CRU 3.5.11)

PARA COMUTAR BANCO DE DADOS

SOFTWARE MANAGMENT > ACTIVE > OK (IRÁ COMUTAR O BANCO DE
DADOS)
OBS: SE O BOTÃO ACTIVATE NÃO ESTIVER HABILITADO, DEVE SE FSZER O
DOWNLOAD NOVAMENTE.

DOWNLOAD
SW DOWNLOAD MENU
SW DOWNLOADING (CLICA EM NE TYPE E APAGA 27)
SELECIONA O PACOTE (1641 V2.7.37)
CLICA CODE PRESENTE.
OBS: FORCED DOWNLOAD SÓ É NECESSÁRIO SE NÃO FUNCIONAR. O CODE
PRESENTE SIGNIFICA QUE O SOFTWARE IRÁ AUTERAR SOMENTE OS DADOS
QUE FOREM DIFERENTES.

CONFIGURAR PROTEÇÃO

EQUIPAMENT CONFIGURATION
TABLE > EPS-ARS
MARCA A PLACA E SELECIONA EPS > CLICA OK > FILE > SEND
P RÁ T I C A  N E C T A S 1641 1651

Más contenido relacionado

La actualidad más candente

Basic cisco commands_by_marcus_nielson_2
Basic cisco commands_by_marcus_nielson_2Basic cisco commands_by_marcus_nielson_2
Basic cisco commands_by_marcus_nielson_2MAFANTIRI SELLO
 
25 most frequently used linux ip tables rules examples
25 most frequently used linux ip tables rules examples25 most frequently used linux ip tables rules examples
25 most frequently used linux ip tables rules exampleschinkshady
 
R E M O T A A T I T E L
R E M O T A  A T I T E LR E M O T A  A T I T E L
R E M O T A A T I T E LFxx
 
QEMU Sandboxing for dummies
QEMU Sandboxing for dummiesQEMU Sandboxing for dummies
QEMU Sandboxing for dummiesEduardo Otubo
 
Trik singkat STATIC ROUTING via cli Packet Tracer
Trik singkat STATIC ROUTING via cli Packet Tracer Trik singkat STATIC ROUTING via cli Packet Tracer
Trik singkat STATIC ROUTING via cli Packet Tracer Selamet Hariadi
 
Honeywell 6160 px-user-guide
Honeywell 6160 px-user-guideHoneywell 6160 px-user-guide
Honeywell 6160 px-user-guideAlarm Grid
 
Ansible ssh y comandos ad-hoc
Ansible ssh y comandos ad-hocAnsible ssh y comandos ad-hoc
Ansible ssh y comandos ad-hocRaul Hugo
 
OSPF (open shortest path first) part iii
OSPF (open shortest path first) part  iiiOSPF (open shortest path first) part  iii
OSPF (open shortest path first) part iiiNetwax Lab
 
How to configure dhcp on a cisco asa 5505
How to configure dhcp on a cisco asa 5505How to configure dhcp on a cisco asa 5505
How to configure dhcp on a cisco asa 5505IT Tech
 
25 most frequently used linux ip tables rules examples
25 most frequently used linux ip tables rules examples25 most frequently used linux ip tables rules examples
25 most frequently used linux ip tables rules examplesTeja Bheemanapally
 

La actualidad más candente (16)

Solaris
SolarisSolaris
Solaris
 
Basic cisco commands_by_marcus_nielson_2
Basic cisco commands_by_marcus_nielson_2Basic cisco commands_by_marcus_nielson_2
Basic cisco commands_by_marcus_nielson_2
 
25 most frequently used linux ip tables rules examples
25 most frequently used linux ip tables rules examples25 most frequently used linux ip tables rules examples
25 most frequently used linux ip tables rules examples
 
R E M O T A A T I T E L
R E M O T A  A T I T E LR E M O T A  A T I T E L
R E M O T A A T I T E L
 
QEMU Sandboxing for dummies
QEMU Sandboxing for dummiesQEMU Sandboxing for dummies
QEMU Sandboxing for dummies
 
Trik singkat STATIC ROUTING via cli Packet Tracer
Trik singkat STATIC ROUTING via cli Packet Tracer Trik singkat STATIC ROUTING via cli Packet Tracer
Trik singkat STATIC ROUTING via cli Packet Tracer
 
Javascript: The Important Bits
Javascript: The Important BitsJavascript: The Important Bits
Javascript: The Important Bits
 
Honeywell 6160 px-user-guide
Honeywell 6160 px-user-guideHoneywell 6160 px-user-guide
Honeywell 6160 px-user-guide
 
9210 commissioning manual
9210 commissioning manual9210 commissioning manual
9210 commissioning manual
 
Ansible ssh y comandos ad-hoc
Ansible ssh y comandos ad-hocAnsible ssh y comandos ad-hoc
Ansible ssh y comandos ad-hoc
 
OSPF (open shortest path first) part iii
OSPF (open shortest path first) part  iiiOSPF (open shortest path first) part  iii
OSPF (open shortest path first) part iii
 
Les02
Les02Les02
Les02
 
Deadlocks in MySQL
Deadlocks in MySQLDeadlocks in MySQL
Deadlocks in MySQL
 
11 things about 11gr2
11 things about 11gr211 things about 11gr2
11 things about 11gr2
 
How to configure dhcp on a cisco asa 5505
How to configure dhcp on a cisco asa 5505How to configure dhcp on a cisco asa 5505
How to configure dhcp on a cisco asa 5505
 
25 most frequently used linux ip tables rules examples
25 most frequently used linux ip tables rules examples25 most frequently used linux ip tables rules examples
25 most frequently used linux ip tables rules examples
 

Destacado

Procedimentos S M E C
Procedimentos  S M E CProcedimentos  S M E C
Procedimentos S M E CFxx
 
I N T E R F A C E S Ó P T I C A S S T M N E C
I N T E R F A C E S Ó P T I C A S  S T M  N E CI N T E R F A C E S Ó P T I C A S  S T M  N E C
I N T E R F A C E S Ó P T I C A S S T M N E CFxx
 
S R A L X D
S R A L  X DS R A L  X D
S R A L X DFxx
 
T R O C A R R L U
T R O C A R  R L UT R O C A R  R L U
T R O C A R R L UFxx
 
A C E S S O A O R A D I O A L C A T E L G G L
A C E S S O  A O  R A D I O  A L C A T E L  G G LA C E S S O  A O  R A D I O  A L C A T E L  G G L
A C E S S O A O R A D I O A L C A T E L G G LFxx
 
C O N E C T A R RÁ D I O N E R A
C O N E C T A R  RÁ D I O  N E R AC O N E C T A R  RÁ D I O  N E R A
C O N E C T A R RÁ D I O N E R AFxx
 
T Server
T ServerT Server
T ServerFxx
 
Sapatas com dupla excentricidade
Sapatas com dupla excentricidadeSapatas com dupla excentricidade
Sapatas com dupla excentricidadeMarcondes11
 
Como agir-em-inundacoes
Como agir-em-inundacoesComo agir-em-inundacoes
Como agir-em-inundacoesHudson777
 
Dicas De Configuração S D H Lucent A D M[1]
Dicas De Configuração  S D H  Lucent  A D M[1]Dicas De Configuração  S D H  Lucent  A D M[1]
Dicas De Configuração S D H Lucent A D M[1]Fxx
 
W D N A L C A T E L
W D N  A L C A T E LW D N  A L C A T E L
W D N A L C A T E LFxx
 
Radio Siemens
Radio SiemensRadio Siemens
Radio SiemensFxx
 
Radio Siemens S R T 1 F
Radio Siemens  S R T 1 FRadio Siemens  S R T 1 F
Radio Siemens S R T 1 FFxx
 
I N T E R F A C E S Ó P T I C A S S T M N E C
I N T E R F A C E S Ó P T I C A S  S T M  N E CI N T E R F A C E S Ó P T I C A S  S T M  N E C
I N T E R F A C E S Ó P T I C A S S T M N E CFxx
 
Digitel
DigitelDigitel
DigitelFxx
 
T R O C A R I D U
T R O C A R  I D UT R O C A R  I D U
T R O C A R I D UFxx
 
1660 S M Oper R4
1660 S M  Oper  R41660 S M  Oper  R4
1660 S M Oper R4Fxx
 
Loop Dla Alcatel Mcl Cen
Loop Dla Alcatel Mcl CenLoop Dla Alcatel Mcl Cen
Loop Dla Alcatel Mcl CenFxx
 
Nt00102dwdm
Nt00102dwdmNt00102dwdm
Nt00102dwdmFxx
 

Destacado (20)

Procedimentos S M E C
Procedimentos  S M E CProcedimentos  S M E C
Procedimentos S M E C
 
I N T E R F A C E S Ó P T I C A S S T M N E C
I N T E R F A C E S Ó P T I C A S  S T M  N E CI N T E R F A C E S Ó P T I C A S  S T M  N E C
I N T E R F A C E S Ó P T I C A S S T M N E C
 
S R A L X D
S R A L  X DS R A L  X D
S R A L X D
 
T R O C A R R L U
T R O C A R  R L UT R O C A R  R L U
T R O C A R R L U
 
A C E S S O A O R A D I O A L C A T E L G G L
A C E S S O  A O  R A D I O  A L C A T E L  G G LA C E S S O  A O  R A D I O  A L C A T E L  G G L
A C E S S O A O R A D I O A L C A T E L G G L
 
C O N E C T A R RÁ D I O N E R A
C O N E C T A R  RÁ D I O  N E R AC O N E C T A R  RÁ D I O  N E R A
C O N E C T A R RÁ D I O N E R A
 
T Server
T ServerT Server
T Server
 
Sapatas com dupla excentricidade
Sapatas com dupla excentricidadeSapatas com dupla excentricidade
Sapatas com dupla excentricidade
 
Como agir-em-inundacoes
Como agir-em-inundacoesComo agir-em-inundacoes
Como agir-em-inundacoes
 
Dicas De Configuração S D H Lucent A D M[1]
Dicas De Configuração  S D H  Lucent  A D M[1]Dicas De Configuração  S D H  Lucent  A D M[1]
Dicas De Configuração S D H Lucent A D M[1]
 
W D N A L C A T E L
W D N  A L C A T E LW D N  A L C A T E L
W D N A L C A T E L
 
Radio Siemens
Radio SiemensRadio Siemens
Radio Siemens
 
Radio Siemens S R T 1 F
Radio Siemens  S R T 1 FRadio Siemens  S R T 1 F
Radio Siemens S R T 1 F
 
I N T E R F A C E S Ó P T I C A S S T M N E C
I N T E R F A C E S Ó P T I C A S  S T M  N E CI N T E R F A C E S Ó P T I C A S  S T M  N E C
I N T E R F A C E S Ó P T I C A S S T M N E C
 
Digitel
DigitelDigitel
Digitel
 
T R O C A R I D U
T R O C A R  I D UT R O C A R  I D U
T R O C A R I D U
 
1660 S M Oper R4
1660 S M  Oper  R41660 S M  Oper  R4
1660 S M Oper R4
 
Loop Dla Alcatel Mcl Cen
Loop Dla Alcatel Mcl CenLoop Dla Alcatel Mcl Cen
Loop Dla Alcatel Mcl Cen
 
50 02rdc
50 02rdc50 02rdc
50 02rdc
 
Nt00102dwdm
Nt00102dwdmNt00102dwdm
Nt00102dwdm
 

Similar a P RÁ T I C A N E C T A S 1641 1651

P RÁ T I C A 1320 C T 1664
P RÁ T I C A 1320  C T 1664P RÁ T I C A 1320  C T 1664
P RÁ T I C A 1320 C T 1664Fxx
 
224698998 moshell-commands
224698998 moshell-commands224698998 moshell-commands
224698998 moshell-commandsAchmad Salsabil
 
How to shutdown and power up of the netapp cluster mode storage system
How to shutdown and power up of the netapp cluster mode storage systemHow to shutdown and power up of the netapp cluster mode storage system
How to shutdown and power up of the netapp cluster mode storage systemSaroj Sahu
 
How to shutdown the Netapp SAN 8.3 and 9.2 version
How to shutdown the Netapp SAN 8.3 and 9.2 versionHow to shutdown the Netapp SAN 8.3 and 9.2 version
How to shutdown the Netapp SAN 8.3 and 9.2 versionSaroj Sahu
 
CCNA Voice workbook
CCNA Voice workbookCCNA Voice workbook
CCNA Voice workbookAce Sabya
 
Install and upgrade Oracle grid infrastructure 12.1.0.2
Install and upgrade Oracle grid infrastructure 12.1.0.2Install and upgrade Oracle grid infrastructure 12.1.0.2
Install and upgrade Oracle grid infrastructure 12.1.0.2Biju Thomas
 
How to shut down Netapp san 9.2 cluster mode version1
How to shut down Netapp san 9.2 cluster mode version1How to shut down Netapp san 9.2 cluster mode version1
How to shut down Netapp san 9.2 cluster mode version1Saroj Sahu
 
CCNA_LAB_MANUAL_part1.pptx
CCNA_LAB_MANUAL_part1.pptxCCNA_LAB_MANUAL_part1.pptx
CCNA_LAB_MANUAL_part1.pptxSanathKumarV3
 
11thingsabout11g 12659705398222 Phpapp01
11thingsabout11g 12659705398222 Phpapp0111thingsabout11g 12659705398222 Phpapp01
11thingsabout11g 12659705398222 Phpapp01Karam Abuataya
 
11 Things About11g
11 Things About11g11 Things About11g
11 Things About11gfcamachob
 
br_test_lossof-datafile_10g.doc
br_test_lossof-datafile_10g.docbr_test_lossof-datafile_10g.doc
br_test_lossof-datafile_10g.docLucky Ally
 
Ora static and-dynamic-listener
Ora static and-dynamic-listenerOra static and-dynamic-listener
Ora static and-dynamic-listenerliu yulin
 
Asm disk group migration from
Asm disk group migration from Asm disk group migration from
Asm disk group migration from Anar Godjaev
 
Trigger and cursor program using sql
Trigger and cursor program using sqlTrigger and cursor program using sql
Trigger and cursor program using sqlSushil Mishra
 
Oracle pl sql
Oracle pl sqlOracle pl sql
Oracle pl sqlDurga Rao
 

Similar a P RÁ T I C A N E C T A S 1641 1651 (20)

P RÁ T I C A 1320 C T 1664
P RÁ T I C A 1320  C T 1664P RÁ T I C A 1320  C T 1664
P RÁ T I C A 1320 C T 1664
 
224698998 moshell-commands
224698998 moshell-commands224698998 moshell-commands
224698998 moshell-commands
 
How to shutdown and power up of the netapp cluster mode storage system
How to shutdown and power up of the netapp cluster mode storage systemHow to shutdown and power up of the netapp cluster mode storage system
How to shutdown and power up of the netapp cluster mode storage system
 
Amos command
Amos commandAmos command
Amos command
 
How to shutdown the Netapp SAN 8.3 and 9.2 version
How to shutdown the Netapp SAN 8.3 and 9.2 versionHow to shutdown the Netapp SAN 8.3 and 9.2 version
How to shutdown the Netapp SAN 8.3 and 9.2 version
 
CCNA Voice workbook
CCNA Voice workbookCCNA Voice workbook
CCNA Voice workbook
 
Install and upgrade Oracle grid infrastructure 12.1.0.2
Install and upgrade Oracle grid infrastructure 12.1.0.2Install and upgrade Oracle grid infrastructure 12.1.0.2
Install and upgrade Oracle grid infrastructure 12.1.0.2
 
Juniper Trouble Shooting
Juniper Trouble ShootingJuniper Trouble Shooting
Juniper Trouble Shooting
 
How to shut down Netapp san 9.2 cluster mode version1
How to shut down Netapp san 9.2 cluster mode version1How to shut down Netapp san 9.2 cluster mode version1
How to shut down Netapp san 9.2 cluster mode version1
 
CCNA_LAB_MANUAL_part1.pptx
CCNA_LAB_MANUAL_part1.pptxCCNA_LAB_MANUAL_part1.pptx
CCNA_LAB_MANUAL_part1.pptx
 
RAC.docx
RAC.docxRAC.docx
RAC.docx
 
11thingsabout11g 12659705398222 Phpapp01
11thingsabout11g 12659705398222 Phpapp0111thingsabout11g 12659705398222 Phpapp01
11thingsabout11g 12659705398222 Phpapp01
 
11 Things About11g
11 Things About11g11 Things About11g
11 Things About11g
 
br_test_lossof-datafile_10g.doc
br_test_lossof-datafile_10g.docbr_test_lossof-datafile_10g.doc
br_test_lossof-datafile_10g.doc
 
Ora static and-dynamic-listener
Ora static and-dynamic-listenerOra static and-dynamic-listener
Ora static and-dynamic-listener
 
Asm disk group migration from
Asm disk group migration from Asm disk group migration from
Asm disk group migration from
 
Trigger and cursor program using sql
Trigger and cursor program using sqlTrigger and cursor program using sql
Trigger and cursor program using sql
 
Go Replicator
Go ReplicatorGo Replicator
Go Replicator
 
Oracle pl sql
Oracle pl sqlOracle pl sql
Oracle pl sql
 
Dbmsmanual
DbmsmanualDbmsmanual
Dbmsmanual
 

Más de Fxx

1008 ProgramaçãO C Completo
1008 ProgramaçãO C Completo1008 ProgramaçãO C Completo
1008 ProgramaçãO C CompletoFxx
 
Ufba Apostila Logica
Ufba Apostila LogicaUfba Apostila Logica
Ufba Apostila LogicaFxx
 
1660 S M Tec R5
1660 S M  Tec  R51660 S M  Tec  R5
1660 S M Tec R5Fxx
 
Senhas Equipamentos
Senhas EquipamentosSenhas Equipamentos
Senhas EquipamentosFxx
 
T Server Mcl3
T Server Mcl3T Server Mcl3
T Server Mcl3Fxx
 
C O N E C T A R L A P T O P N A R E D E T E L E M A R
C O N E C T A R  L A P  T O P  N A  R E D E  T E L E M A RC O N E C T A R  L A P  T O P  N A  R E D E  T E L E M A R
C O N E C T A R L A P T O P N A R E D E T E L E M A RFxx
 
P I N A G E M C A B O S ( L A P T O Ps)
P I N A G E M  C A B O S ( L A P  T O Ps)P I N A G E M  C A B O S ( L A P  T O Ps)
P I N A G E M C A B O S ( L A P T O Ps)Fxx
 
A S G A M M O63 E1
A S G A  M M O63 E1A S G A  M M O63 E1
A S G A M M O63 E1Fxx
 
S A L V A R P E R F O R M A N C E D E P F A
S A L V A R  P E R F O R M A N C E  D E  P F AS A L V A R  P E R F O R M A N C E  D E  P F A
S A L V A R P E R F O R M A N C E D E P F AFxx
 
1660 S M Operator S Handbook Rel4
1660 S M  Operator S  Handbook  Rel41660 S M  Operator S  Handbook  Rel4
1660 S M Operator S Handbook Rel4Fxx
 
RÁ D I O S I E M E N S S R T I F
RÁ D I O  S I E M E N S  S R T  I FRÁ D I O  S I E M E N S  S R T  I F
RÁ D I O S I E M E N S S R T I FFxx
 
T E L E S S U P E R V I SÃ O T E L E M U L T
T E L E S S U P E R V I SÃ O  T E L E M U L TT E L E S S U P E R V I SÃ O  T E L E M U L T
T E L E S S U P E R V I SÃ O T E L E M U L TFxx
 
Pasolink
PasolinkPasolink
PasolinkFxx
 
Tricanal
TricanalTricanal
TricanalFxx
 
C O N E C T A R S R A 4
C O N E C T A R  S R A 4C O N E C T A R  S R A 4
C O N E C T A R S R A 4Fxx
 

Más de Fxx (15)

1008 ProgramaçãO C Completo
1008 ProgramaçãO C Completo1008 ProgramaçãO C Completo
1008 ProgramaçãO C Completo
 
Ufba Apostila Logica
Ufba Apostila LogicaUfba Apostila Logica
Ufba Apostila Logica
 
1660 S M Tec R5
1660 S M  Tec  R51660 S M  Tec  R5
1660 S M Tec R5
 
Senhas Equipamentos
Senhas EquipamentosSenhas Equipamentos
Senhas Equipamentos
 
T Server Mcl3
T Server Mcl3T Server Mcl3
T Server Mcl3
 
C O N E C T A R L A P T O P N A R E D E T E L E M A R
C O N E C T A R  L A P  T O P  N A  R E D E  T E L E M A RC O N E C T A R  L A P  T O P  N A  R E D E  T E L E M A R
C O N E C T A R L A P T O P N A R E D E T E L E M A R
 
P I N A G E M C A B O S ( L A P T O Ps)
P I N A G E M  C A B O S ( L A P  T O Ps)P I N A G E M  C A B O S ( L A P  T O Ps)
P I N A G E M C A B O S ( L A P T O Ps)
 
A S G A M M O63 E1
A S G A  M M O63 E1A S G A  M M O63 E1
A S G A M M O63 E1
 
S A L V A R P E R F O R M A N C E D E P F A
S A L V A R  P E R F O R M A N C E  D E  P F AS A L V A R  P E R F O R M A N C E  D E  P F A
S A L V A R P E R F O R M A N C E D E P F A
 
1660 S M Operator S Handbook Rel4
1660 S M  Operator S  Handbook  Rel41660 S M  Operator S  Handbook  Rel4
1660 S M Operator S Handbook Rel4
 
RÁ D I O S I E M E N S S R T I F
RÁ D I O  S I E M E N S  S R T  I FRÁ D I O  S I E M E N S  S R T  I F
RÁ D I O S I E M E N S S R T I F
 
T E L E S S U P E R V I SÃ O T E L E M U L T
T E L E S S U P E R V I SÃ O  T E L E M U L TT E L E S S U P E R V I SÃ O  T E L E M U L T
T E L E S S U P E R V I SÃ O T E L E M U L T
 
Pasolink
PasolinkPasolink
Pasolink
 
Tricanal
TricanalTricanal
Tricanal
 
C O N E C T A R S R A 4
C O N E C T A R  S R A 4C O N E C T A R  S R A 4
C O N E C T A R S R A 4
 

Último

ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemkeProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemkeProduct Anonymous
 
AWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of TerraformAWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of TerraformAndrey Devyatkin
 
The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024Rafal Los
 
Strategies for Landing an Oracle DBA Job as a Fresher
Strategies for Landing an Oracle DBA Job as a FresherStrategies for Landing an Oracle DBA Job as a Fresher
Strategies for Landing an Oracle DBA Job as a FresherRemote DBA Services
 
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...apidays
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerThousandEyes
 
Scaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationScaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationRadu Cotescu
 
Why Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire businessWhy Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire businesspanagenda
 
Polkadot JAM Slides - Token2049 - By Dr. Gavin Wood
Polkadot JAM Slides - Token2049 - By Dr. Gavin WoodPolkadot JAM Slides - Token2049 - By Dr. Gavin Wood
Polkadot JAM Slides - Token2049 - By Dr. Gavin WoodJuan lago vázquez
 
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...apidays
 
Top 5 Benefits OF Using Muvi Live Paywall For Live Streams
Top 5 Benefits OF Using Muvi Live Paywall For Live StreamsTop 5 Benefits OF Using Muvi Live Paywall For Live Streams
Top 5 Benefits OF Using Muvi Live Paywall For Live StreamsRoshan Dwivedi
 
GenAI Risks & Security Meetup 01052024.pdf
GenAI Risks & Security Meetup 01052024.pdfGenAI Risks & Security Meetup 01052024.pdf
GenAI Risks & Security Meetup 01052024.pdflior mazor
 
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot TakeoffStrategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoffsammart93
 
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...DianaGray10
 
Deploy with confidence: VMware Cloud Foundation 5.1 on next gen Dell PowerEdg...
Deploy with confidence: VMware Cloud Foundation 5.1 on next gen Dell PowerEdg...Deploy with confidence: VMware Cloud Foundation 5.1 on next gen Dell PowerEdg...
Deploy with confidence: VMware Cloud Foundation 5.1 on next gen Dell PowerEdg...Principled Technologies
 
MINDCTI Revenue Release Quarter One 2024
MINDCTI Revenue Release Quarter One 2024MINDCTI Revenue Release Quarter One 2024
MINDCTI Revenue Release Quarter One 2024MIND CTI
 
2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...Martijn de Jong
 
Understanding Discord NSFW Servers A Guide for Responsible Users.pdf
Understanding Discord NSFW Servers A Guide for Responsible Users.pdfUnderstanding Discord NSFW Servers A Guide for Responsible Users.pdf
Understanding Discord NSFW Servers A Guide for Responsible Users.pdfUK Journal
 
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, AdobeApidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobeapidays
 
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024The Digital Insurer
 

Último (20)

ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemkeProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
 
AWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of TerraformAWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of Terraform
 
The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024
 
Strategies for Landing an Oracle DBA Job as a Fresher
Strategies for Landing an Oracle DBA Job as a FresherStrategies for Landing an Oracle DBA Job as a Fresher
Strategies for Landing an Oracle DBA Job as a Fresher
 
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected Worker
 
Scaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationScaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organization
 
Why Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire businessWhy Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire business
 
Polkadot JAM Slides - Token2049 - By Dr. Gavin Wood
Polkadot JAM Slides - Token2049 - By Dr. Gavin WoodPolkadot JAM Slides - Token2049 - By Dr. Gavin Wood
Polkadot JAM Slides - Token2049 - By Dr. Gavin Wood
 
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
 
Top 5 Benefits OF Using Muvi Live Paywall For Live Streams
Top 5 Benefits OF Using Muvi Live Paywall For Live StreamsTop 5 Benefits OF Using Muvi Live Paywall For Live Streams
Top 5 Benefits OF Using Muvi Live Paywall For Live Streams
 
GenAI Risks & Security Meetup 01052024.pdf
GenAI Risks & Security Meetup 01052024.pdfGenAI Risks & Security Meetup 01052024.pdf
GenAI Risks & Security Meetup 01052024.pdf
 
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot TakeoffStrategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
 
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
 
Deploy with confidence: VMware Cloud Foundation 5.1 on next gen Dell PowerEdg...
Deploy with confidence: VMware Cloud Foundation 5.1 on next gen Dell PowerEdg...Deploy with confidence: VMware Cloud Foundation 5.1 on next gen Dell PowerEdg...
Deploy with confidence: VMware Cloud Foundation 5.1 on next gen Dell PowerEdg...
 
MINDCTI Revenue Release Quarter One 2024
MINDCTI Revenue Release Quarter One 2024MINDCTI Revenue Release Quarter One 2024
MINDCTI Revenue Release Quarter One 2024
 
2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...
 
Understanding Discord NSFW Servers A Guide for Responsible Users.pdf
Understanding Discord NSFW Servers A Guide for Responsible Users.pdfUnderstanding Discord NSFW Servers A Guide for Responsible Users.pdf
Understanding Discord NSFW Servers A Guide for Responsible Users.pdf
 
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, AdobeApidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
 
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
 

P RÁ T I C A N E C T A S 1641 1651

  • 1. PRÁTICA NECTAS 1641-1651 ACESSAR O NECTAS USUÁRIO – ADMIN SENHA – ADMIN BELL > DISABLE BACKUP 1641 – SM SALVAR: EQUIPAMENT CONFIGURATION CONNECTION CONFIGURATION LOCAL CONFIGURATION ROUTING TABLES 1651 – SM SALVAR: EQUIPAMENT CONFIGURATION CONNECTION CONFIGURATION WITH FULL MATRIX CONNECTION CONFIGURATION WITH VC4 MATRIX DROP SHELF CONNECTION CONFIGURATION LOCAL CONFIGURATION ROUTING TABLES (SE HOUVER DÚVIDA SALVAR TUDO) OBS: ONDE TIVER DROP SHELF NÃO PRECISA SALVAR (1641 SMD), NO 1651 VAI ESTAR A MATRIX FULL OU A VC4. DROP SHELF É UM SUB BASTIDOR DO 1641 ASSOCIADO AO 1651. O 1651 É EQUIPADO ATÉ 1 STM1, COM O DROP SHELF ESSA CAPACIDADE É AMPLIADA COM 3 STM1, FICANDO ATÉ 4 STM1. EXECUTANDO BACKUP ABRIR ELEMENTO DE REDE (DUPLO CLICK) EQUIPAMENT CONFIGURATION > FILE > RECIVE DIGITAR DADOS DA ESTAÇÃO > OK CONNECTION CONFIGURATION FILE > RECIVE DIGITAR DADOS DA ESTAÇÃO > OK LOCAL CONFIGURATION FILE > RECIVE DIGITAR DADOS DA ESTAÇÃO > OK ROUTING TABLES FILE > RECIVE
  • 2. DIGITAR DADOS DA ESTAÇÃO > OK PARA SALVAR EM OUTRA PASTA IR ATÉ A PASTA C: ALCATEL /1641 SM 27 OU 1651 SM 25 (COPIA PARA A PSTA DA ESTAÇÃO SEM AUTERAR O ARQUIVO) TROCAR SMEC 1 2 DIP SWITCH ON OFF POSIÇÃO NORMAL OFF ON POSIÇÃO LIMPEZA DE BANCO DE DADOS OFF OFF RECUPERAR LOCAL CONFIGURATION (NE, OS ADRESS, LAPD, ETHERNET). ON ON RETAURAR O BANCO DE DADOS ON OFF POSIÇÃO NORMAL PASSOS: PASSO 1 - RETIRAR A SMEC DIP 1 OFF DIP 2 ON – INSERIR A PLACA E AGUARDA O LED ABN ACENDER. (O BANCO FOI LIMPO). PASSO 2 - RETIRAR A SMEC DIP I OFF DIP 2 ON – INSERIR A PLACA, AGUARDA O LED ABN ACENDER.(FOI RECUPERADO LOCAL CONFIGURATION). PASSO 3- RETIRAR A SMEC DIP I ON DIP 2 ON – INSERIR A PLACA, AGUARDA O LED ABN ACENDER.(ENVIAR AS TABELAS DE BACKUP AO NE). PASSO 4 - RETIRAR A SMEC DIP I ON DIP 2 OFF – INSERIR A PLACA, AGUARDA O LED ABN ACENDER. PARA RESTORE FILE SEND (SELECIONA ARQUIVO DA ESTAÇÃO E CLICA OK) SEQUENCIA DE TABELAS: CONNECTION CONFIGURATION EQUIPMENT CONFIGURATION LOCAL CONFIGURATION ROUTING TABLES DEMAIS TABELAS INSERIR NA GERÊNCIA LAPD ETHERNET CONFIG (Só para cne´s)
  • 3. 1- LAPD ABRIR ELEMENTO DE REDE (DUPLO CLICK) CLICA EM LAPD CONFIGURATION >AGRR STMI E1 (USER) >AGRR STM1W1 (NETWORK) LOCAL CONFIGURATION > YES > NETWORK TABLES > MS LAPD CONFIGURATION E1 > W1 2 – ETH > YES > FALSE (L2 ONLY) 3 – OS ADRESS INSERIR NSAP DA GERÊNCIA NO NO 4 – NE ADRESS (LOCAL CONFIGURATION) INSERIR NSAP E 7.1 (ADRESS DO NE) SISTEM ID (EX 002060222222) 7.1 = 8 FILE > SAVE > FILE > SEND. OBS-SE HOUVER MUDANÇA DO NSAP, O SISTEMA EXECUTA REBOOT. É NECESSÁRIO CONECTAR NOVAMENTE. ACESSO REMOTO 1 – DECLARAR NO MEU ELEMENTO DE REDE, OS NSAP´S QUE QUERO VER REMOTAMENTE. LOCAL / CONFIG > R-ECT YES (MARCA) DIGITA NSAP E 7.1 ADRESS DOS NE´S REMOTOS. CLICA EM NEXT PARA CRIAR OUTRO NE. FILE > SAVE > FILE > SEND. FECHAR O NECTAS 2 – MENU INICIAR >PROGRAMAS > ALCATEL > NETWORK CONFIG >NETWORK CONFIGURATION >NETWORK > CREATE > DEFAUT > NETWORK NAME (GENERAL) > CREATE 3 – ABRIR PAINT BRUSH PARA CRIAR UM FUNDO, QUE SERÁ INSERIDO NA REDE (GENERAL).
  • 4. FAÇA UM “COPY” NO PAINT BRUSH E UM “MAP > PASTE” NO MAPA GENERAL. 4 – CRIAR UM NE GENÉRICO QUALQUER EQUIPAMENT > CREATE > ME (0) > SECONDARY ADRESS (5) > CREATE BOTÃO ESQUERDO > LOCATE EQUIPAMENT > LOCALIZE 5 – EDITAR WIN INI IR A C: / WINT / WIN.INI E EDITAR COM OS DADOS: [ PEX ] COMPEX=COM1: PEXLOAD= 12TimRetrasmiis=20sec 12TimPolling=4sec 12TimResponse=5sec 12Retry=1 NETCFG_RECT=YES NETCFG_NETWORK=C:/NETWORK/REDE/ TXTPATH=C:NETWORK/REDE/TXTFILE/ NETWORK_RF=REDE NETPATH=C:/NETWORK/REDE/NETFILE/ WMFPATH=C:/NETWORK/REDE/WMFILE/ NETWORK=REDE OBS-CASO O NOME DO MAPA SEJA GENERAL, SUBSTITUIR A PALAVRA REDE POR GENERAL. 6 – ABRIR O NECTAS VIW > NETWORK (Aparecerá todos os elementos criados) OBS-de 2 a 5 é a configuração do Laptop VIW > SUB NETWORK / EQUIPAMENTS ( duplo click) ALARMS E STATUS > OK CROSS CONEXÃO CRIANDO CIRCUITO DE 2 MB ABRE O NE (duplo click) CONNECTION CONFIGURATION > OK FILE > RECIVE > SELECIONA ESTAÇÃO > OK (Salva) TABLE > PAYLOAD STRUTURE AND SIGNAL LABEL > OK TABLE > TU-12´S ALLOCATION FOR 21X2M/SCDMA TRIBUTARY > OK EQUIPA O TRIBUTÁRIO EQUIPA O TU12 (CRIAR CORRESPONDENCIA COM O LADO REMOTO) EQUIPA O MODE (D / I BIDI UNP E OU W (E OU W DE ACORDO COM O PROJETO, UM LADO E O OUTRO W)).
  • 5. FILE > SEND > SAVE > SEND OBS= NO LADO REMOTO DEVE SE FAZER O MESMO PROCESSO 1641, 1651, 1664 SÓ DOIS AGREGADOS. FAZER LOOP 2MB ABRE O NE (duplo click) CLICA ALARMES, STATUS AND REMOTE CONTROLS > OK CLICA LOGIC > T2M 1 (PLACA DE TRIBUTÁRIO PRINCIPAL) CLICA NO TRIBUTÁRIO CLICA REMOTE_CONTROL CURRENT DISPLAY ENABLE INT LOOP 2M (PARA DENTRO DO EQUIPAMENTO) LOOP REMOTO ENABLE LINE LOOP 2M (PARA FORA DO EQUIPAMENTO) – INSTRUMENTO FAZER LOOP DE AGREGADO ABRE O NE (duplo click) CLICA ALARMES, STATUS AND REMOTE CONTROLS > OK CLICA LOGIC > AG-1 E1 (IN) PLACA DE AGREGADO PRINCIPAL CLICA REMOTE_CONTROL CURRENT DISPLAY ENABLE INT LOOP (PARA DENTRO DO EQUIPAMENTO) LOOP REMOTO ENABLE LINE LOOP (PARA FORA DO EQUIPAMENTO) – INSTRUMENTO FORÇAR LASER ABRE O NE (duplo click) CLICA FILE > RECIVE > SAVE > TABLE > OPTICAL SAFETY CONFIGURATION SELECIONA A OPÇÃO DESEJADA: ALS DISABLE SET TX ON (LASER FORÇADO) ALS DISABLE SET TX OFF (LASER DESLIGADO) ALS DISABLE (CONDIÇÃO NORMAL DE LASER) FILE SEND > OK (CONFERIR A ESTAÇÃO) OBS: PARA DESFAZER REPETE O PROCESSO.
  • 6. FORÇAR COMUTAÇÃO ABRE O NE (duplo click) CLICA FILE > RECIVE > SAVE > ALARMS, STATUS AND REMOTE CONTROLS > > CLICA LOGIC > CLICA NA PLACA CORRESPONDENTE ( EX AGGR MAIN) > REMOTE CONTROL > CURRENT DISPLAY > > MANUAL ACTIVE STM1 AGGR OBS: PARA RETIRAR A COMUTAÇÃO FORÇADA > SELECIONA A PLACA > REMOTE CONTROL > CURRENT DISPLAY > > CLEAR FORCE ACTIVE STM1 AGG * COMUTAÇÃO MANUAL: VERIFICA O OUTRO RECURSO ANTES DE COMUTAR * COMUTAÇÃO FORÇADA NÃO VERIFICA O OUTRO RECURSO ANTES DE COMUTAR. SINCRONISMO CRU MAIN ABRE O NE (duplo click) FILE > RECIVE > SAVE > EQUIPMENT CONFIGURATION > OK FILE > RECIVE … AGUARDA NOMEIA A ESTAÇÃO > OK TABLE > SYNCRHRONIZATION: ADM TYPE & TRIBUTARY CONFIGURATION > OK MARCA SINGLE ADM SE QUIZER 2M SELECIONA TRIB 1,2,OU 3 E A PORTA = 1° PORTA CLICA EM OK TABLE > SYNCRHRONIZATION PRIORITY LIST CONFIGURATION > OK Fazer sair por T4 o sinal que tiver entrando na entrada de sincronismo externo T3. Normalmente T4=T0. Referência 1- 2 MHz = GPS (melhor relógio, qualidade G811) Priority de 1 a 6 (1 mais prioritário) Squelch , bloqueia o sinal de relógio se não for melhor ou igual a referência indicada. OBS: O sistema procura trabalhar com a melhor qualidade, depois avalia a prioridade. Sequencia de qualidade: G811, G812t, G812l, G813. SSM ALGORITHM ENABLE = MARCAR (É QUEM DEFINE PARA OLHAR PRIMEIRO A QUALIDADE) > CLICA EM OK TABLE > SYNCRHRONIZATION: SSM VALUE CONFIGURATION
  • 7. INFORMA A QUALIDADE: EXTRATED PARA RX ( E1 OU W1) INSERTED PARA TX (E1 OU W1) CLICA EM OK SOFTWARE MISMASH CRU MAIN ALARMANDO (PODE SE COMUTAR A SMEC) VERSÃO DE UNIDADES ABRE O NE (duplo click) CLICA FILE > RECIVE > SAVE > ALARMS, STATUS AND REMOTE CONTROLS > SW VERSION > CLICA NA PLACA PARA VER PACOTE DE SOFTWARE ABRE O NE > SOFTWARE DOWNLOAD > (VERIFICAR VERSÕES, PACOTE SMEC, DOWNLOADS) > NE IDENTIFICATION > (MOSTRA 2 PACOTES DE SOFTWARES DENTRO DA SMEC EX 1641 V2.7.37) > DESCRIPTOR FILE > (VERIFICA AS VERSÕES DAS UNIDADES EX CRU 3.5.11) PARA COMUTAR BANCO DE DADOS SOFTWARE MANAGMENT > ACTIVE > OK (IRÁ COMUTAR O BANCO DE DADOS) OBS: SE O BOTÃO ACTIVATE NÃO ESTIVER HABILITADO, DEVE SE FSZER O DOWNLOAD NOVAMENTE. DOWNLOAD SW DOWNLOAD MENU SW DOWNLOADING (CLICA EM NE TYPE E APAGA 27) SELECIONA O PACOTE (1641 V2.7.37) CLICA CODE PRESENTE. OBS: FORCED DOWNLOAD SÓ É NECESSÁRIO SE NÃO FUNCIONAR. O CODE PRESENTE SIGNIFICA QUE O SOFTWARE IRÁ AUTERAR SOMENTE OS DADOS QUE FOREM DIFERENTES. CONFIGURAR PROTEÇÃO EQUIPAMENT CONFIGURATION TABLE > EPS-ARS MARCA A PLACA E SELECIONA EPS > CLICA OK > FILE > SEND