Gateway Business Solutions, A Solution provider in Telecom, Access Control, Time Attendance, Digital Security and Surviellance and Office automation. Pioneers in VOIP solutions like IP PBX, CALL CENTRE SOLUTIONS etc.
Description
Gateway Business Solution is a Distributor to M/S Matrix Comsec Pvt Ltd, for their Range of Telecom and Security Products and solutions. MATRIX Analog, Digital and IP Pbx solutions and Security products such as Door Access and Time Attendance Products (Proximity and Biometric)
Gateway is also Channel Partner for M/s Intellicon Pvt Ltd for their range of Telecom Products. Transtel, Karel, NEC IP EPABX systems and Radvision and Lifesize Video Conferencing Solutions.
Gateway is also a pioneer in offering VOIP solutions ranging from Soft IP PBX, Call Centre Solutions, Automatic Voice Campaigner etc.
Contact :
Gateway Business Solutions
2nd Flr, Sai Krupa, 33 Durga Nagar Colony
Punjagutta
Hyderabad 500 082
Ph: 93978 20222
3. Agenda
• COSEC Introduction
• COSEC Building Blocks
• What is PANEL and When PANEL is Required?
• COSEC PE,GE,ME and LE Licensing
• COSEC Architecture
• Applications
• Functions and Features
5. Introduction
• A System to Control Access to Areas and Resources
• Defines the security of the valuable Assets
• Time Attendance define the Productivity of the
Organization
• Designed to meet Optimum use of Access Control,
Time and Attendance
• Prevents Unauthorized Entry
• Stores Maximum of 10,000,00 (1Million) User
Database and Unlimited Event logs
• Employee Self Service (ESS) and Visitor
Management Modules*
* Optional
6. Introduction
Visitor
Management
Access Control ESS
Matrix
COSEC
Unauthorized Restriction Time and Attendance
9. COSEC Architecture
• COSEC has a layered Architecture
• The Top most part of COSEC Architecture is Web
Based Application Server
• COSEC software in COSEC Architecture can be
deployed in three parts:
Web Application Server
Database sever
Web Client
• COSEC PANEL in COSEC Architecture Manages
Multiple Door Controller
• Door Controller and Readers Allow/Deny Entry and
exit of the Users
13. Building Blocks
• COSEC APPLICATION SOFTWARE
• COSEC PANEL/PANEL LITE
• COSEC DOOR Controllers (V1/V2)Family
CAS
FOS
FCS
CAP
FOP
FCP
• External/Exit Reader
21. Door Technical Specification
Communication Ethernet 10Mbps and RS485
External Reader 1 Port for Card or Fingerprint Reader
External Reader Interfaces RS232 and Wiegand
External Reader Power 12VDC@0.5A
Exit Switch Port Yes
Door Status Sense Programmable NO, NC, Supervised
Door Lock Relay Relay SPDT, Form C, 1A@30VDC
Door Lock Power Internal12VDC@0.5A or External
Auxiliary Input Port Programmable NO, NC, Supervised
Auxiliary Output Relay Relay SPDT, Form C, 1A@30VDC
Tamper Detection Yes
Buzzer Yes
Indications 4 LEDs for Status, Alarm, Allowed and Denied
CPU 16-Bit Micro-Controller
Memory 16KB SRAM, 256KB+128KB Flash
-100 C to +500C (140F to 1220F), 5% to 95% RH Non-
Environment
Condensing
23. Door Controller V1-Features
• Support RS485 and Ethernet Interface for Connectivity
• One port for External Card or Finger Print Reader
• Support RS232 and Wiegand Interface for External
Reader
• Up to 500 Users Capacity without PANEL
• Store 5,000 Events Log without PANEL
• Built-in Power Supply for 1 External device
• Supervised Alarm Input Port
• Auxiliary Output Relay Contact
• Audio & Visual Indication (LEDs, Buzzer)
24. Door Controller V2-Features
• Support RS485,Ethernet for Connectivity
• One port for External Card or Finger Print Reader
• Support RS232 and Wiegand Interface for External
Reader
• Up to 2000 Users Capacity without PANEL
• Store 50,000 Events Log without PANEL
• Built-in Power Supply for 1 External device
• Supervised Alarm Input Port
• Auxiliary Output Relay Contact
• Built-in USB Port
• Audio & Visual Indication (LEDs, Buzzer)
26. COSEC FCX-Features
FCX- “Finger” “Capacitive” “neXt” “EXcellent”
“EXecutive”
• 3.1 Mega Pixels Camera
• 7” touch sense TFT LCD
• WI-FI and Ethernet
• USB Port
• Photo capture and storage
• Graphical user interface
• Multimedia functions
• Multiple languages
29. COSEC Software Salient Features
• Web Based Comprehensive Access Control cum Time-
& Attendance Software
• Controls up to 1000 PANELS
• Easy to Program and Configure
• Real Time Monitoring and Control
• Wide range of Reports Generation capability
• User Definable Data Export Option for 3rd Party Payroll-
Software
33. What is PANEL?
• PANEL is a Site Controller for the Multiple Doors
• Hardware of Access control and Alarm Monitoring
Application
• Controls Readers, Door contact Inputs and Relays
• Supports for 10,000 Users database
• Storage for Finger Print Templates For Easy replacement
of Door Controllers
34. What is PANEL?
• Store Up to 1,00,000 User Events in PANEL Memory
• Communicate with Door Controllers via RS485 or
Ethernet Interface
• IP address Assignment and Configuration of the PANEL
Door through PANEL
• Automatic Door firmware upgrade from PANEL
• Automatic verification of Door Firmware at startup
• Synchronizes Clock of all Door Controllers
35. What is PANEL?
• Matrix COSEC Door can be configured in Two Different
Ways –Panel Door/Direct Door
Panel Door COSEC Application
PANEL
PANEL Door Depends on PANEL for Configuration
Door
Direct Door COSEC Application
Direct Door Depend on COSEC Application for Configuration
36. When PANEL is Required?
1.Users (per door) exceeds the standalone capacity of Door
controller(i.e.500 users- DoorV1 and 2000-Door V2)
2.Local events storage requirement(per door) exceeds the standalone
capacity of Door(i.e.5000 events –Door V1;50,000 events –
DoorV2)
3.When the following Advanced access control feature(s) are needed:
• Access Zones/Access Groups
• First-In User
• 2-Person Rule
• Occupancy Control
• Man trap
• Dead-Man Zone
• Anti-Pass Back
• Guard tour
• DND
37. Door V2 & NGT- Advanced Access Features
Following Advanced Access control features are also
available on direct doors-V2 and NGT
• Absentee Rule
• First In User
• Occupancy Control
• Use Count Control
• Anti Pass Back
• 2 Person Rule
38. PANEL -Technical Specification
CPU 32-Bit RISC
Operating System Linux
LED Indicators Power, Mains Fail, Battery Fail, Alarm and Fault
Memory 32MB SDRAM, 32MB Flash
Host Communication Ethernet 10/100Mbps
Door Communication Ethernet 10Mbps and RS485
USB 1 Port (Device)(Future Use)
Alarm Input Port 1 (Supervised)
Auxiliary Output Port Relay SPDT, Form C, 5A@28VDC
Tamper Detection Yes
Buzzer Yes
Power Supply 90-285VAC, 47-63Hz
Built-in Charger for Internal 12V/7AH Battery (Battery
Battery Backup
Not Supplied)
Power Output for Door
4 Ports, Each 12VDC@1A
Controller
-100 C to +500C (140F to 1220F), 5% to 95% RH Non-
Environmental
Condensing
39. PANEL LITE- Technical Specification
CPU 32 Bit RISC
Operating Systems Linux
LED Indicators Power , Status ,Alarm
Memory 32MB SDRAM,32MB Flash
Host Communication Ethernet 10/100 Mbps
Door Communication Ethernet 10/100 Mbps and RS485
USB 1 Port
Auxiliary Input Port 1 Port
Auxiliary Output Port 1Relay ,SPDT(Form C) 5A@28VDC
Tamper Detection N/A
Buzzer/Alarm Yes
Power Input 12V DC,1.25A
Battery Backup N/A
Power Output for Door Controller N/A
Environmental -100 C to +500C (140F to 1220F), 5% to 95
RH Non-Condensing
40. PANEL - Interfaces
• Ethernet and RS485 Port for Network connectivity
• Built-in Power Supply for 4 DOORs
• Supervised Alarm Input Port
• Auxiliary Output Relay Contact
• Audio & Visual Indication (LEDs, Buzzer)
• USB port
45. COSEC PANEL Salient Features
• Support up to 75 DOORs
- Maximum 75 DOORs on Ethernet
- Maximum 32 DOORs on RS485
- Maximum 75 DOORs in a heterogeneous environment
• 1,000,000 (1Million) Users Capacity
• Store 1,00,000 Events Log
• Built-in Power Supply for 4 DOORs
• Supervised Alarm Input Port
• Auxiliary Output Relay Contact
• Built-in USB Port*( future option)
• Audio & Visual Indication (LEDs, Buzzer)
46. COSEC PANEL LITE Salient Features
• Support up to 16 DOORs
-Maximum 16 DOORs on Ethernet
- Maximum 16 DOORs on RS485
- Maximum 16 DOORs in a heterogeneous environment
• 1,000,000 (1Milion) Users Capacity
• Store 1,00,000 Events Log
• Supervised Alarm Input Port
• Auxiliary Output Relay Contact
• Built-in USB Port
• Audio & Visual Indication (LEDs, Buzzer)
• Absence of Battery Backup and Tamper Alarm
• Wireless communication ability with the COSEC server
through WI-FI/Mobile Broadband
47. Door Controller Topology
• Door Controllers in COSEC Architecture can be
connected in three different ways :-
Ethernet(TCP/IP) Connection-For Panel & Direct doors
RS485 (Serial) Connection(Supports upto 1200 mts.)
-For Panel doors Only
Mix/Heterogeneous Mode (Both Ethernet and RS485)
- For Panel doors Only
48. Ethernet Connectivity
DOOR
Lock
DOOR
Exit Switch Controller
Network Switch
Matrix
PANE
L COSEC ERA
Single DOOR Architecture
49. Ethernet Connectivity
DOOR
Controller
Network Switch
COSEC PANEL COSEC Server
Multi DOOR Architecture
52. COSEC –Internal/External Readers
There are Three Types of Readers which can be connected to
Door Controller :-
• Internal Card Readers
• Internal Finger Print Reader
• External Reader
* External Reader can be connected using Wiegand or
RS232 interface
54. COSEC CA Reader
• RFID(Proximity/Smart card) Reader
• RS232 interface
• Tamper detection
• LED Indications
• Built- in buzzer
• Power supply from door
55. COSEC FC Reader
• Finger print reader(Capacitive)
• RS232 interface
• Tamper detection
• LED Indications
• Built- in buzzer
• Power supply from door
56. COSEC FO Reader
• Finger print reader(Optical)
• RS232 interface
• Tamper detection
• LED Indications
• Built- in buzzer
• Power supply from door
58. Card Support
EM Prox and HID Prox : Proximity Card (125KHz Low Frequency)
HID : Smart Card (13.56 MHz High Frequency)
• iCLASS (U- Reader: UART interface and W- Reader: Weigand interface)
• MIFARE
59. Card Reader Interface Support
• Wiegand :
Distance Coverage 150 meters from Door Controller
Uses D0 and D1 Lines for communication
• Serial RS232 :
Distance coverage is 4.5 meters from Door Controller
Uses Rx and Tx for communication
60. Card Reader Interface Support
150 Meter
Wiegand
Entry Reader Exit Reader
4.5 Meter
RS232
Entry Reader
Exit Reader
65. COSEC Family Selection
• PE (Potential Enterprise)
• GE (Growing Enterprise)
• ME (Medium Enterprise)
• LE (Large Enterprise)
NOTE: EMM (Enrollment Management Module) is available with all
the licenses and VMM(Visitor Management Module) is Optional
66. COSEC Selection
Default 1000 users
and expandable
upto 1 million
70. Access Control System
User Credential
Exit
Switch Exit
Switch
DOOR
Controller DOOR
Controller
User
User
Matrix Matrix
PANEL PANEL
Application Application
software software
72. T&A Application For SMB
• Fig Shows Simple Installation
of two DOOR Controllers for
a Time Attendance solution in
Small Business setup
• DOOR Controllers are Directly
connected with COSEC
Application Software
• Common Attendance Policy and
Management can be apply
through COSEC Application
Software
73. T&A Application For SME
• Fig Shows Simple Installation
of Four DOOR Controllers for
a Time Attendance solution in
Medium Business setup
• DOOR Controllers are Directly
connected with COSEC
Application Software
• Common Attendance Policy
and Management can be apply
through COSEC Application
Software
75. Access Control Application
Campus Application
• Fig shows the COSEC
installation in an organization
campus for access control
• Door Controllers are
installed at various division
of the organization
• All door controllers are
centrally connected with a
PANEL
• The system is monitored and
controlled by COSEC
Application software
76. Access Control Application
Multi- Floor Application
• Fig shows the Typical Deployment
of COSEC in Multi Floor Building
for access control
• Door Controllers are connected
with the COSEC PANEL and
installed at various Floor with Entry
and Exit Reader
• All door controllers are centrally
connected with a PANEL
• The complete system is monitored
and controlled by COSEC
Application Software
77. Access Control Application
Multi- Location Application
• Fig shows the COSEC
deployment in an organization
spread at various part of the
globe
• COSEC PANEL are installed
at each location with multiple
Door Controllers
• Administrator can apply
common access control and
time Attendance policies for
all location
• The system is monitored and
controlled by COSEC
Application software Centrally
79. COSEC Functions
• Web Based Access Control
• Distributed Database
• Time-Attendance
• Leave Management
• Visitor Management
• Built-in Alarm Detection and Management
• Web Based Interface for Monitoring System
83. COSEC Features-Access Control
• Access Zones
• Access Groups
• Access Levels
• 2-Person Group
• Anti-Pass back
• Degrade Mode Access
• Dead Man Zone
• Do Not Disturb Zone
• Duress Detection
85. COSEC- Other Features
• Shifts/Schedules
• Wide variety of Reports Generation
• Holiday Schedules
• Import Data
• Export Data
• Tamper Detection
• Special Function Cards
87. Reports Generation
• Reports Available Within the ACMS Time and
Attendance Module are Categorized as
- Master Reports
- Transaction Reports
- Branch
- Category
89. Transaction Reports
- Category
- In/Out Event
- In/Out Event Summary
- Late In
- Early In
- OT Reason
- Early Out
- Reporting Group
- Overstay
- Absentee
90. Transaction Reports
- Continuous Absentee
- Exception
- Attendance
- Attendance Summary
- Scheduled Shift
- Shift Change
- COFF Register
- Late Memo
- Absent Memo
- Week off And Holiday
- Muster Roll
- Muster Summery
92. Shift Schedule
• Useful Feature for Organizations Working in multiple
Shifts
• Multiple Shifts Based on Requirements
• Maximum Six Shifts Per Schedule group can be defined;
And a total of 99 shifts can be defined in the software.
Shift-1 Shift-2 Shift-3 Shift-4
General Morning Second Night
94. Special Function Cards
• User Can Access Various Predefined Cards to
Perform the Various Functions like Late In, Early
Out etc.
• Need not to Dial or Remember Code for Routine
Functions
• User Has to Show Only his Identity After Showing
this Card
• 38 Predefined Functions With Maximum 4 Cards Per
Function
96. Tamper Detection
• Alarm provision when any Tampering With the System is
Detected
• Possible on Both, PANEL and DOOR Controller
• Generates Alarm On PANEL and DOOR Based on
Programming
• Can be Disabled Temporary for Maintenance Purpose