This document provides information about Anish Industrial Corporation, including that it is a two decade old company that manufactures and exports aluminum conductors, galvanized steel stranded wires, and other products used in power transmission and distribution lines. It describes having the necessary infrastructure, quality management systems, and testing facilities to ensure high quality products. Tables are included that list various aluminum conductor and stranded wire products with their specifications.
3. INTRODUCTION
We are a Two decade old Company entrenched in the Engineering Industry for Manufacturing
& Exporting of Bare Aluminium Conductors namely AAC, ACSR & AAAC Conductors,
Galvanized Steel Stranded Stay wires, Aluminium Binding Wires & Tapes, Barbed Wire, Earth
Wire, Conductor & Earth Wire Accessories, Preformed & Helical Products, Pole Line Hardware &
Tower Accessories etc. which are mainly used in Power Transmission & Distribution Lines for Rural
Electrification purpose. With optimum quality imbibed in our range, we are thriving to become one of
the leaders in our ambit of operations. The quality assurance in our range has been possible because of
several factors like our well developed Infrastructure, our dexterous team and our Quality
Management. All of these factors have lead us in garnering ISO 9001: 2008 Certification. All testing
facilities for IN HOUSE testing of manufactured goods are installed in the works and all the goods are
in-house tested during every stage of manufacture as per relevant ISS, BSS, ASTM, CA-C, JISG,
DIN, SLS, BIS, specification of National & International Standard. The Company is embarking on
to increase its Domestic as well as Export Market presence for all its Products.
15. BSI
TM
NABCB
A N I S H
ISO 9001:2008
SAVE TRANSMISSION LOSSES
QM 008
Certificate No. FM-82353
BASIC TECHNICAL DATA OF STRANDED CONDUCTORS
Modulus of Elasticity and Coefficients of Linear Expansion for Constructions of Aluminium Conductors
Steel-Reinforced to IEC Publ. No. 209
Number of Wires
Final Modulus of Elasticity
Coefficient of Linear Expansion
Al
St
Kg/mm2
Ib/in2
1/CO
1/FO
6
6
12
18
24
26
28
30
30
32
54
54
1
7
7
1
7
7
7
7
19
19
7
19
81.00
77.00
107.00
67.00
74.00
77.00
79.00
82.00
80.00
82.00
70.00
68.00
11.5 x 106
11.0 x 106
15.2 x 106
9.5 x 106
10.5 x 106
10.9 x 106
11.2 x 106
11.6 x 106
11.4 x 106
11.7 x 106
9.9 x 106
9.7 x 106
19.1 x 10-6
19.8 x 10-6
15.3 x 10-6
21.2 x 10-6
19.6 x 10-6
18.9 x 10-6
18.4 x 10-6
17.8 x 10-6
18.0 x 10-6
17.5 x 10-6
19.3 x 10-6
19.4 x 10-6
10.6 x 10-6
11.0 x 10-6
8.5 x 10-6
11.8 x 10-6
10.9 x 10-6
10.5 x 10-6
10.2 x 10-6
9.9 x 10-6
10.0 x 10-6
9.7 x 10-6
10.7 x 10-6
10.8 x 10-6
H
S
I
ALUMINIUM WIRES
DENSITY : Aluminium wire density at 20OC is 2.703 kg/dm
TEMPERATURE COEFFICIENT : At a temperature of 20OC. This figure is 0.00403 (OC)
RESISTIVITY : The resistivity at 20OC should not exceed 0.028264
LINEAR EXPANSIVITY : Aluminium wire linear expansivity is 23 x 10-6 (OC)
GALVANIZED STEEL WIRES
DENSITY : Galvanized wire density at 20OC is 7.80 kg/dm
LINEAR EXPANSIVITY : The linear expansivity of galvanized steel wire used in aluminium steel cable cores is 11.5x10-6 (1/OC)
N
A
11
16. BSI
NABCB
A N I S H
ISO 9001:2008
SAVE TRANSMISSION LOSSES
IS : 398 (PART IV) 1994
Actual
Area
Stranding
& Wire
Dia
Approx
Overall
Dia.
Approx
Mass
mm2
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
QM 008
Certificate No. FM-82353
All Aluminium Alloy Conductor (A.A.A.C.)
Sl.
No.
TM
mm
mm
kg/km
15
22
34
55
80
100
125
148
173
200
232
288
346
400
465
525
570
604
642
695
767
3/2.50
7/2.00
7/2.50
7/3.15
7/3.81
7/4.26
19/2.89
19/3.15
19/3.40
19/3.66
19/3.94
37/3.15
37/3.45
37/3.71
37/4.00
61/3.31
61/3.45
61/3.55
61/3.66
61/3.81
61/4.00
5.39
6.00
7.50
9.45
11.43
12.78
14.45
15.75
17.00
18.30
19.70
22.05
24.15
25.97
28.00
29.79
31.05
31.95
32.94
34.29
36.00
40.15
60.16
94.00
149.20
218.26
272.86
342.51
406.91
474.02
549.40
636.67
794.05
952.56
1 101.63
1 280.50
1 448.39
1 573.71
1 666.00
1 771.36
1 919.13
2 115.54
Calculated
Maximum
Resistance
at20OC
Ù/ Km
Approx.
Calculated
Breaking
Load
2.304 0
1.541 0
0.990 0
0.621 0
0.425 0
0.339 0
0.273 5
0.229 0
0.196 9
0.171 0
0.147 1
0.118 2
0.098 4
0.082 9
0.073 4
0.065 1
0.059 8
0.056 8
0.053 4
0.049 2
0.044 6
4.33
6.45
10.11
16.03
23.41
29.26
36.64
43.50
50.54
58.66
68.05
84.71
101.58
117.40
136.38
146.03
158.66
167.99
178.43
193.25
213.01
kN
NOTES
H
S
I
1. The actual area of a stranded conductor has been taken as the sum of the cross-sectional areas of the individual
N
A
wires of nominal diameter.
2. Maximum resistance values of stranded conductor have been calculated on the basis of maximum resistivity and
the cross sectional area based on the minimum diameter.
12
17. BSI
TM
NABCB
A N I S H
ISO 9001:2008
SAVE TRANSMISSION LOSSES
QM 008
Certificate No. FM-82353
All Aluminium Alloy Conductor (A.A.A.C.)
BS : 3242
Nominal
Aluminium
Area
Stranding
and Wire
Diameter
Sectional
Area
Approximate
overall
Diameter
Approximate
Mass Per
km
Calculated
Breaking
Load
Nominal
Aluminium
Area
Kg/Km
Calculated
D.C.
Resistance
at 20OC
Ù/km
mm2
mm
mm2
mm
kN
mm2
25
30
40
50
100
150
175
300
7/2.34
7/2.54
7/2.95
7/3.30
7/1.65
19/3.48
19/3.76
37/3.53
30.10
35.47
47.84
59.87
118.9
180.7
211.0
362.1
7.02
7.62
8.85
9.80
13.95
17.40
18.80
24.71
82
97
131
164
325
497
580
997
1.094
0.9281
0.6880
0.5498
0.2769
0.1830
0.1568
0.09155
8.44
9.94
13.40
16.80
33.30
50.65
59.10
101.5
25
30
40
50
100
150
175
300
H
S
I
NOTES
1. The sectional area of an aluminium alloy stranded conductor is the sum of the cross sectional areas of the individual wires.
2. Attention is drawn to the fact that the sectional areas of stranded conductors covered by the specification refer to aluminium
alloy areas. Consequently they are larger than the nominal aluminium areas by which they are identified.
N
A
13
18. BSI
TM
NABCB
A N I S H
ISO 9001:2008
SAVE TRANSMISSION LOSSES
QM 008
Certificate No. FM-82353
GALVANIZED STEEL STRANDS
Based on Single Wires of s.w.g. Sizes
No of Strands
3 Strands
SINGLE WIRE SIZE S.W.G.
Weight per 100 yds.
Weight per mile
Weight per kilometre
Weight per kilometre
Length per 100 Ibs.
Length per cwt
Length per 100 kilos.
Length per 100 kilos.
Ibs.
Ibs.
Ibs.
kilos.
yds.
yds.
yds.
metres.
8
4 Strands
9
61.79
1,087.5
676
306.5
162
181.2
357
326
8
50.06
881.1
548
248.3
200
223.7
440
403
9
82.48
1,451.7
902
409.2
121
135.7
267
244
Ibs.
Ibs.
Ibs.
kilos.
yds.
yds.
yds.
metres.
7
8
9
10
174.82
3,076.8
1,912
867.2
57
64.1
126
115
144.46
2,542.5
1,580
716.6
69
77.5
153
140
117.03
2,059.8
1,280
580.6
85
95.7
188
172
92.43
1,626.8
1,011
458.5
108
121.2
239
218
N
A
SINGLE WIRE SIZE S.W.G.
Weight per 100 yds.
Weight per mile
Weight per kilometre
Weight per kilometre
Length per 100 Ibs.
Length per cwt
Length per 100 kilos.
Length per 100 kilos.
66.82
1,176.1
731
331.5
150
167.5
330
302
8
52.78
928.9
577
261.8
190
212.2
418
382
9
103.21
1,816.5
1,129
512.0
97
108.6
214
195
83.61
1,471.6
914
414.8
120
134.0
264
241
7 Strands
SINGLE WIRE SIZE S.W.G.
No of Strands
10
H
S
I
No of Strands
Weight per 100 yds.
Weight per mile
Weight per kilometre
Weight per kilometre
Length per 100 Ibs.
Length per cwt
Length per 100 kilos.
Length per 100 kilos.
5 Strands
Ibs.
Ibs.
Ibs.
kilos.
yds.
yds.
yds.
metres.
7
8
9
10
475.99
8,377.5
5,206
2,361.6
21
23.5
46
42
393.33
6,922.7
4,302
1,951.5
25
28.5
56
51
318.66
5,608.5
3,485
1,581
31
35,1
69
63
251.67
4,429.4
2,752
1,248.6
40
44.5
88
80
12
14
16
18
20
61.06
1,074.6
668
302.9
164
183.4
361
330
36.11
635.6
395
179.1
277
310.3
611
558
23.11
406.8
253
114.7
433
484.5
954
872
13.0
228.8
142
64.5
769
861.7
1,696
1,551
7.31
128.7
80
36.3
1,368
1,531.2
3,016
2,785
12
14
16
18
20
166.24
2,925.9
1,818
824.7
60
67.4
133
121
98.33
1,730.7
1,075
487.8
102
113.9
224
205
62.93
1,107.6
688
312.2
159
177.9
350
320
35.4
623
387
175.6
283
316.4
623
570
19.91
350.5
218
98.8
502
562.3
1,107
1,013
19 Strands
14
19. BSI
TM
NABCB
A N I S H
ISO 9001:2008
SAVE TRANSMISSION LOSSES
QM 008
Certificate No. FM-82353
H
S
I
PVC INSULATED CONDUCTOR
BARBED WIRE
N
A
ALUMINIUM BINDING WIRE
ALUMINIUM BINDING TAPE
15
20. PART B
POWER TRANSMISSION AND
DISTRIBUTION LINE MATERIALS
1) TRANSMISSION, DISTRIBUTION AND POLE LINE HARDWARE
ACCESSORIES::
Cross Arms, Pole Brackets, Pole Clamps, Tie Strap, Terminating Strap, Stay Set, Earthing Rod,
Tension Hardware fittings, Suspension Hardware fittings, Turn Buckle, Stay Clamp, Insulator Pins, D
Iron Bracket, Various Types of Line Taps & H Connectors etc
2) CONDUCTOR & EARTH WIRE HARDWARE ACCESSORIES &
VIBRATION DAMPERS::
Tension Clamp, Suspension Clamp, Mid Span Compression Joint, Repair Sleeves, Parallel Groove
Clamps, Vibration Damper, Earth Bond, Suspension Clamp & Tension Clamps for Earth Wire etc
3) PREFORMED & HELICAL PRODUCTS FOR CONDUCTOR & EARTH
WIRE::
Preformed Armour Rod, Dead Ends, Guy Grip, Service Grip Dead End, Side Ties, Distribution Ties,
Line Splices, Pole Top Make Off & Line Guards etc
4) TOWER & TOWER ACCESSORIES::
Single Circuit, Double Circuit, Stubs, Extension Tower, Danger Plate, Phase Plate, Anti Climbing
Device & Bird Guard etc
5) SUB STATION CLAMPS AND CONNECTORS::
T- Clamps (Both Compression & Bolted Type), Various Types of Isolator Clamps, Connectors, PG Clamps &
Spacers etc
21. BSI
TM
NABCB
A N I S H
ISO 9001:2008
SAVE TRANSMISSION LOSSES
QM 008
Certificate No. FM-82353
TRANSMISSION, DISTRIBUTION AND POLE LINE HARDWARE ACCESSORIES
H
S
I
Forging Components
Forging Components
Forging Components
H. Connector
Tension Hardware
Insulator Pin
Clamp
Socket Eye
N
A
Ball Hook
Suspension Hardware
400kV Twin
Suspension Fittings
400kV Double
Tension Fittings
D Iron Bracket
Turn Buckle
Fabricated Steel Plates
16
23. BSI
TM
NABCB
A N I S H
ISO 9001:2008
SAVE TRANSMISSION LOSSES
QM 008
Certificate No. FM-82353
CONDUCTOR, EARTH WIRE HARDWARE ACCESSORIES & VIBRATION DAMPERS
AGS Clamp
H
S
I
Cross By Clamp
N
A
Hardware Fittings
Mid Span Compression Joint
Suspension Clamps
Vibration Damper
PG Clamp
Tension Clamps
Spiral Vibration Damper
18
24. BSI
TM
NABCB
A N I S H
ISO 9001:2008
SAVE TRANSMISSION LOSSES
QM 008
Certificate No. FM-82353
PREFORMED & HELICAL PRODUCTS FOR CONDUCTOR & EARTH WIRE
H
S
I
N
A
Guy Grip
Dead End Grip
Helical Products
Preformed Armour Rod
Preformed Products
Service Grip Dead End
19
25. BSI
TM
NABCB
A N I S H
ISO 9001:2008
SAVE TRANSMISSION LOSSES
QM 008
Certificate No. FM-82353
TOWER & TOWER ACCESSORIES
Single Circuit Steel Tower
N
A
Danger Plate
Y
B
H
S
I
Line Tower - Single & Double Circuit
with Extension
Phase Plate
Single Circuit Lattice Steel Tower
Anti Climbing Guard
Danger Plate
Stub Tower Legs
Tower Installation
R
20
26. BSI
TM
NABCB
A N I S H
ISO 9001:2008
SAVE TRANSMISSION LOSSES
QM 008
Certificate No. FM-82353
SUB STATION CLAMPS AND CONNECTORS
H
S
I
400 kV Sub-Station Connectors
N
A
21
27.
28. ANISH INDUSTRIAL CORPORATION
I S O
:
9 0 0 1 : 2 0 0 8
Corporate Office :
135, Biplabi Rash Behari Basu Road,
2nd Floor, Kolkata - 700 001,
West Bengal, India
C E R T I F I E D
Works :
212, Raja Ramchand Ghat Road, Panihati,
24 Pgs. (N), Kolkata - 700 114,
West Bengal, India
Tel : +91 33 2242 1004, Fax : +91 33 2210 1882
E-mail : anishindustrial@gmail.com / sales.anishind@gmail.com,