Datablad-DVM-360-Cassette-2021.pdf

  1. • 360 degree air supply. • Bladeless discharge. Booster fans can be individually controlled, allowing for completely horizontal flow discharge. Coandă effect is created even without ceiling. • Built-in condensation drain pump. • Predisposition of the air inlet to let fresh air in. • Compatible with Wi-Fi Kit controller. • Circular or square cassette panel. • Motion Detector Sensor included. • Optional SPi Kit • Optional Air Purification Panel, Auto Elevation Panel Model AM045KN4DEH/EU AM056KN4DEH/EU AM071KN4DEH/EU AM090KN4DEH/EU AM112KN4DEH/EU AM128KN4DEH/EU AM140KN4DEH/EU PowerSupply Φ, #, V, Hz 1Φ, 2, 220–240 V, 50 Hz 1Φ, 2, 220–240 V, 50 Hz 1Φ, 2, 220–240 V, 50 Hz 1Φ, 2, 220–240 V, 50 Hz 1Φ, 2, 220–240 V, 50 Hz 1Φ, 2, 220–240 V, 50 Hz 1Φ, 2, 220–240 V, 50 Hz Performance Capacity (Nominal) Cooling kW 4.5 5.6 7.1 9.0 11.2 12.8 14.0 Heating kW 5.0 6.3 8.0 10.0 12.5 13.8 16.0 Power PowerInput (Nominal) Cooling W 26 30 34 55 53 77 91 Heating W 26 30 34 55 53 77 91 Current Input (Nominal) Cooling A 0.18 0.21 0.25 0.42 0.41 0.62 0.75 Heating A 0.18 0.21 0.25 0.42 0.41 0.62 0.75 Fan Motor Type - Turbo Fan Turbo Fan Turbo Fan Turbo Fan Turbo Fan Turbo Fan Turbo Fan Output x n w 65 x 1 65 x 1 65 x 1 65 x 1 97 x 1 97 x 1 97 x 1 Airflow Rate H/M/L (UL) m³/min 14.50/13.50/12.50 16.00/14.50/13.50 18.00/16.00/14.00 22.00/18.50/16.00 25.50/21.00/17.50 29.50/24.00/19.00 31.50/26.50/21.00 l/s 241.67/225.00/208.33 266.67/241.67/225.00 300.00/266.67/233.33 366.67/308.33/266.67 425.00/350.00/291.67 491.67/400.00/316.67 525.00/441.67/350.00 Piping Connections Liquid Pipe ø, mm 6.35 6.35 9.52 9.52 9.52 9.52 9.52 ø, inch 1/4 1/4 3/8 3/8 3/8 3/8 3/8 Gas Pipe ø, mm 12.70 12.70 15.88 15.88 15.88 15.88 15.88 ø, inch 1/2 1/2 5/8 5/8 5/8 5/8 5/8 Drain Pipe ø, mm VP25 (OD 32, ID 25) VP25 (OD 32, ID 25) VP25 (OD 32, ID 25) VP25 (OD 32, ID 25) VP25 (OD 32, ID 25) VP25 (OD 32, ID 25) VP25 (OD 32, ID 25) Field Wiring PowerSource Wire mm² 1.5–2.5 1.5–2.5 1.5–2.5 1.5–2.5 1.5–2.5 1.5–2.5 1.5–2.5 Transmission Cable mm² 0.75–1.50 0.75–1.50 0.75–1.50 0.75–1.50 0.75–1.50 0.75–1.50 0.75–1.50 Refrigerant Type - R410A(Fluorinated greenhouse gas, GWP=2,088) R410A(Fluorinated greenhouse gas, GWP=2,088) Control Method - EEV INCLUDED EEV INCLUDED EEV INCLUDED EEV INCLUDED EEV INCLUDED EEV INCLUDED EEV INCLUDED Sound Sound Pressure1 (H/M/L) dB(A) 33/31/29 34/32/29 36/33/30 40/36/32 40/36/32 42/38/33 44/40/35 Sound Power Cooling dB(A) 50 51 53 57 58 60 61 Dimension Net Weight kg 21.0 21.0 21.0 21.0 24.0 24.0 24.0 Net Dimensions (W x H x D) mm 947 x 281 x 947 947 x 281 x 947 947 x 281 x 947 947 x 281 x 947 947 x 365 x 947 947 x 365 x 947 947 x 365 x 947 Panel Model Name - PC4NUDMAN PC4NUDMAN PC4NUDMAN PC4NUDMAN PC4NUDMAN PC4NUDMAN PC4NUDMAN Specifications 360 Cassette Accessories Wireless Remote Controller Simple Type Controller Touch Controller Wired Remote Controller Wi-Fi Kit External Room Sensor AR-KH03E MWR-SH00N MWR-SH11N MWR-WG00*N MIM-H04EN MRW-TA Panel (Mandatory) Panel (Mandatory) Panel (Mandatory) Panel (Mandatory) AirPurification Panel (Optional) Auto Elevation Panel (Optional) PC4NUDMAN PC4NUNMAN PC4NBDMAN PC4NBNMAN PC6EUCMAN PC6EUXMAN Motion Detect Sensor SPi Kit MCR-SME MSD-CAN1 1 Sound pressure level is obtained in an anechoic room. Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound pressure level may differ depending on operation conditions. 114 115 VRF VRF
  2. AM045KN4DEH/EU, AM056KN4DEH/EU, AM071KN4DEH/EU, AM090KN4DEH/EU AM112KN4DEH/EU, AM128KN4DEH/EU AM140KN4DEH/EU NO Name 1 Refrigerant liquid pipe 2 Refrigerant gas pipe 3 Condensate drain 4 Power supply/communication wiring conduits 5 Air discharge opening 6 Air suction grille 7 Suction rim for booster fan 8 Corner decoration cover 9 Drain hose 10 Fresh air intake knock-out hole 11 Display window 12 Infrared receiver NO Name 1 Refrigerant liquid pipe 2 Refrigerant gas pipe 3 Condensate drain 4 Power supply/communication wiring conduits 5 Air discharge opening 6 Air suction grille 7 Suction rim for booster fan 8 Corner decoration cover 9 Drain hose 10 Fresh air intake knock-out hole 11 Display window 12 Infrared receiver 1. Make sure the spacing between the ceiling and the cassette is no more than 29 mm [1 1/4”]. Max ceiling opening: 960 mm [3’1 3/4”] 2. When the conditions exceed 30 °C and RH 80 % in the ceiling or fresh air inducted into the ceiling, additional insulation is required (polythene foam, thickness 10 mm [3/8”] or more) 3. Open type panel model code: PC4NUDMAN 1. Make sure the spacing between the ceiling and the cassette is no more than 29 mm [1 1/4”]. Max ceiling opening: 960 mm [3’1 3/4”] 2. When the conditions exceed 30 °C and RH 80 % in the ceiling or fresh air inducted into the ceiling, additional insulation is required (polythene foam, thickness 10 mm [3/8”] or more) 3. Open type panel model code: PC4NUDMAN Dimensional drawings 360 Cassette (square) 116 117 VRF VRF
  3. AM045KN4DEH/EU, AM056KN4DEH/EU, AM071KN4DEH/EU, AM090KN4DEH/EU Dimensional drawings 360 Cassette (circular) AM112KN4DEH/EU, AM128KN4DEH/EU, AM140KN4DEH/EU NO Name 1 Refrigerant liquid pipe 2 Refrigerant gas pipe 3 Condensate drain 4 Power supply/communication wiring conduits 5 Air discharge opening 6 Air suction grille 7 Suction rim for booster fan 8 Corner decoration cover 9 Drain hose 10 Fresh air intake knock-out hole 11 Display window 12 Infrared receiver NO Name 1 Refrigerant liquid pipe 2 Refrigerant gas pipe 3 Condensate drain 4 Power supply/communication wiring conduits 5 Air discharge opening 6 Air suction grille 7 Suction rim for booster fan 8 Corner decoration cover 9 Drain hose 10 Fresh air intake knock-out hole 11 Display window 12 Infrared receiver 1. Make sure the spacing between the ceiling and the cassette is no more than 10 mm [3/8”]. 2. When the conditions exceed 30 °C and RH 80 % in the ceiling or fresh air inducted into the ceiling, additional insulation is required (polythene foam, thickness 10 mm [3/8”] or more) 3. Open type panel model code: PC4NUNMAN 4. The circular panel is available by default in the exposed installation. 5. Make inspection holes on the ceiling for easier installation and maintenance, as shown in the following table. (An inspection hole must be at least 450 mm x 450 mm in size.) 6. A suspended ceiling structure can substitute for the inspection holes. 1. Make sure the spacing between the ceiling and the cassette is no more than 10 mm [3/8”]. 2. When the conditions exceed 30 °C and RH 80 % in the ceiling or fresh air inducted into the ceiling, additional insulation is required (polythene foam, thickness 10 mm [3/8”] or more) 3. Open type panel model code: PC4NUNMAN 4. The circular panel is available by default in the exposed installation. 5. Make inspection holes on the ceiling for easier installation and maintenance, as shown in the following table. (An inspection hole must be at least 450 mm x 450 mm in size.) 6. A suspended ceiling structure can substitute for the inspection holes. Category Inspection hole Recessed installation Exposed installation Integrated Suspended Square Panel 1 ea - Circle Panel 2 ea Category Inspection hole Recessed installation Exposed installation Integrated Suspended Square Panel 1 ea - Circle Panel 2 ea 118 119 VRF VRF
Publicidad