©2009 Mourne Training Services Dear Lab Tech Guy, I am working in QC, doing mainly HPLC analysis. I am often confused by the composition of seal wash and needle wash. Do you have any advice on what is the right composition of both that increase efficiency of HPLC? Yours, Virender (Bangalore, India) ?
©2009 Mourne Training Services Dear Virender, To answer your question I will briefly describe the purpose of both seal wash and needle wash. The most suitable composition for each follows logically from their purpose. Seal wash is used to rinse the backs of the piston seals in the pump of a HPLC system. The piston is the part of the pump which moves back and forward in the pump head drawing in and pushing out the mobile phase solvent with each movement. Because it is a moving part, a seal around this piston is required to prevent the liquid leaking out the back of the pump.  Piston Seal
©2009 Mourne Training Services Over a period of time small amounts of mobile phase solvents seep through the seal to the back of the pump head. If these solvents contain buffers then the salts may precipitate out forming deposits which can shorten the life of the seal.   Seal wash is used when the mobile phase contains buffers. The wash flushes the back of the piston seals removing any deposits and maximising the lifetime of the seal. Seal Wash? It follows that the composition of the seal wash should be aqueous to dissolve buffers.  A small amount of organic solvent is added to prevent bacteria growth and also to reduce the surface tension of the water (this helps the wash solvent cling to surfaces). Typical seal wash composition is 90% water and 10% organic solvent.  The organic solvent may be methanol, acetonitrile or isopropyl alcohol (IPA).
The needle in the HPLC system is used to introduce the sample into the mobile phase so that it can be separated on the HPLC column. The needle wash is used to clean the needle after an injection. The design of the needle in the injector system varies for different manufacturers. In some designs the inside of the needle is part of the flow path of the mobile phase and thus it is flushed continuously by the mobile phase between injections. In this case it is the outside of the needle which is cleaned by the needle wash. In other designs the needle is separate from the mobile phase flow path and thus the needle wash is used to clean the inside and outside of the needle. In all cases the composition of the needle wash needs to be matched to the sample since this is what you want to clean off the needle.  Therefore the selection of a suitable needle wash is part of the development of a particular HPLC method. Typically a composition of needle wash which matches the proportions of aqueous and organic solvents in the mobile phase will be appropriate (assuming you are using reversed phase HPLC). ©2009 Mourne Training Services
If the needle is not cleaned correctly then you may experience carryover between injections where sample from the previous injection which has not been cleaned from the needle will interfere with the next injection. Needle wash procedures will also help to prolong the life of the seals in the injection system. Appropriate selection of seal wash and needle wash solvents will help you in the quest for trouble free operation of your HPLC system and ensure that your analysis is not a washout.   Yours chromatographically,  ©2009 Mourne Training Services You’ve run the analysis, now eat the snack (?)
Brought to you by... www.mournetrainingservices.co.uk ©2009 Mourne Training Services

Más contenido relacionado

Destacado

HPLC2010 Pharmaceutical Copolymer Excipient Characterization By GPC-FTIR
HPLC2010  Pharmaceutical Copolymer Excipient Characterization By GPC-FTIRHPLC2010  Pharmaceutical Copolymer Excipient Characterization By GPC-FTIR
HPLC2010 Pharmaceutical Copolymer Excipient Characterization By GPC-FTIR
mzhou45
 
Hplc (basic principles, operation and maintenance)
Hplc (basic principles, operation and maintenance)Hplc (basic principles, operation and maintenance)
Hplc (basic principles, operation and maintenance)
alim125135
 
Tablet friability,harness and dissolution testing
Tablet friability,harness and dissolution testingTablet friability,harness and dissolution testing
Tablet friability,harness and dissolution testing
donjacob81
 

Destacado (16)

Analog Labs- Analytical validation and Method development Training in AR&D
Analog Labs- Analytical validation and Method development Training in AR&DAnalog Labs- Analytical validation and Method development Training in AR&D
Analog Labs- Analytical validation and Method development Training in AR&D
 
Analog Labs - SAS IN PHARMA INDUSTRY & Basic CDM:
Analog Labs - SAS IN PHARMA INDUSTRY & Basic CDM:Analog Labs - SAS IN PHARMA INDUSTRY & Basic CDM:
Analog Labs - SAS IN PHARMA INDUSTRY & Basic CDM:
 
Cannabis Analyzer for Potency Provides Effortless Determination of Cannabinoi...
Cannabis Analyzer for Potency Provides Effortless Determination of Cannabinoi...Cannabis Analyzer for Potency Provides Effortless Determination of Cannabinoi...
Cannabis Analyzer for Potency Provides Effortless Determination of Cannabinoi...
 
New EMA Guidance on Real Time Release Testing.
New EMA Guidance on Real Time Release Testing.New EMA Guidance on Real Time Release Testing.
New EMA Guidance on Real Time Release Testing.
 
HPLC Trouble Shotting
HPLC  Trouble ShottingHPLC  Trouble Shotting
HPLC Trouble Shotting
 
HPLC2010 Pharmaceutical Copolymer Excipient Characterization By GPC-FTIR
HPLC2010  Pharmaceutical Copolymer Excipient Characterization By GPC-FTIRHPLC2010  Pharmaceutical Copolymer Excipient Characterization By GPC-FTIR
HPLC2010 Pharmaceutical Copolymer Excipient Characterization By GPC-FTIR
 
Hplc (basic principles, operation and maintenance)
Hplc (basic principles, operation and maintenance)Hplc (basic principles, operation and maintenance)
Hplc (basic principles, operation and maintenance)
 
Compressor trouble shooting
Compressor trouble shootingCompressor trouble shooting
Compressor trouble shooting
 
Handling of Out of Specification Results
Handling of Out of Specification ResultsHandling of Out of Specification Results
Handling of Out of Specification Results
 
validation and calibration of HPLC
validation and calibration of HPLCvalidation and calibration of HPLC
validation and calibration of HPLC
 
Out of specification (oos)1
Out of specification (oos)1Out of specification (oos)1
Out of specification (oos)1
 
HPLC[ HIGH PERPROMANCE LIQUID CHROMATOGRAPHY OR HIGH PRESSURE LIQUID CHROMAT...
HPLC[ HIGH PERPROMANCE LIQUID CHROMATOGRAPHY OR  HIGH PRESSURE LIQUID CHROMAT...HPLC[ HIGH PERPROMANCE LIQUID CHROMATOGRAPHY OR  HIGH PRESSURE LIQUID CHROMAT...
HPLC[ HIGH PERPROMANCE LIQUID CHROMATOGRAPHY OR HIGH PRESSURE LIQUID CHROMAT...
 
Out of specification shravan
Out of specification shravanOut of specification shravan
Out of specification shravan
 
Handling OOS results
Handling OOS resultsHandling OOS results
Handling OOS results
 
Quality control measures in pharmaceutical industry
Quality control measures in pharmaceutical industryQuality control measures in pharmaceutical industry
Quality control measures in pharmaceutical industry
 
Tablet friability,harness and dissolution testing
Tablet friability,harness and dissolution testingTablet friability,harness and dissolution testing
Tablet friability,harness and dissolution testing
 

Último

Último (20)

This PowerPoint helps students to consider the concept of infinity.
This PowerPoint helps students to consider the concept of infinity.This PowerPoint helps students to consider the concept of infinity.
This PowerPoint helps students to consider the concept of infinity.
 
ICT Role in 21st Century Education & its Challenges.pptx
ICT Role in 21st Century Education & its Challenges.pptxICT Role in 21st Century Education & its Challenges.pptx
ICT Role in 21st Century Education & its Challenges.pptx
 
HMCS Vancouver Pre-Deployment Brief - May 2024 (Web Version).pptx
HMCS Vancouver Pre-Deployment Brief - May 2024 (Web Version).pptxHMCS Vancouver Pre-Deployment Brief - May 2024 (Web Version).pptx
HMCS Vancouver Pre-Deployment Brief - May 2024 (Web Version).pptx
 
80 ĐỀ THI THỬ TUYỂN SINH TIẾNG ANH VÀO 10 SỞ GD – ĐT THÀNH PHỐ HỒ CHÍ MINH NĂ...
80 ĐỀ THI THỬ TUYỂN SINH TIẾNG ANH VÀO 10 SỞ GD – ĐT THÀNH PHỐ HỒ CHÍ MINH NĂ...80 ĐỀ THI THỬ TUYỂN SINH TIẾNG ANH VÀO 10 SỞ GD – ĐT THÀNH PHỐ HỒ CHÍ MINH NĂ...
80 ĐỀ THI THỬ TUYỂN SINH TIẾNG ANH VÀO 10 SỞ GD – ĐT THÀNH PHỐ HỒ CHÍ MINH NĂ...
 
Application orientated numerical on hev.ppt
Application orientated numerical on hev.pptApplication orientated numerical on hev.ppt
Application orientated numerical on hev.ppt
 
REMIFENTANIL: An Ultra short acting opioid.pptx
REMIFENTANIL: An Ultra short acting opioid.pptxREMIFENTANIL: An Ultra short acting opioid.pptx
REMIFENTANIL: An Ultra short acting opioid.pptx
 
Wellbeing inclusion and digital dystopias.pptx
Wellbeing inclusion and digital dystopias.pptxWellbeing inclusion and digital dystopias.pptx
Wellbeing inclusion and digital dystopias.pptx
 
COMMUNICATING NEGATIVE NEWS - APPROACHES .pptx
COMMUNICATING NEGATIVE NEWS - APPROACHES .pptxCOMMUNICATING NEGATIVE NEWS - APPROACHES .pptx
COMMUNICATING NEGATIVE NEWS - APPROACHES .pptx
 
UGC NET Paper 1 Mathematical Reasoning & Aptitude.pdf
UGC NET Paper 1 Mathematical Reasoning & Aptitude.pdfUGC NET Paper 1 Mathematical Reasoning & Aptitude.pdf
UGC NET Paper 1 Mathematical Reasoning & Aptitude.pdf
 
FSB Advising Checklist - Orientation 2024
FSB Advising Checklist - Orientation 2024FSB Advising Checklist - Orientation 2024
FSB Advising Checklist - Orientation 2024
 
Micro-Scholarship, What it is, How can it help me.pdf
Micro-Scholarship, What it is, How can it help me.pdfMicro-Scholarship, What it is, How can it help me.pdf
Micro-Scholarship, What it is, How can it help me.pdf
 
Unit 3 Emotional Intelligence and Spiritual Intelligence.pdf
Unit 3 Emotional Intelligence and Spiritual Intelligence.pdfUnit 3 Emotional Intelligence and Spiritual Intelligence.pdf
Unit 3 Emotional Intelligence and Spiritual Intelligence.pdf
 
Fostering Friendships - Enhancing Social Bonds in the Classroom
Fostering Friendships - Enhancing Social Bonds  in the ClassroomFostering Friendships - Enhancing Social Bonds  in the Classroom
Fostering Friendships - Enhancing Social Bonds in the Classroom
 
SOC 101 Demonstration of Learning Presentation
SOC 101 Demonstration of Learning PresentationSOC 101 Demonstration of Learning Presentation
SOC 101 Demonstration of Learning Presentation
 
How to Manage Global Discount in Odoo 17 POS
How to Manage Global Discount in Odoo 17 POSHow to Manage Global Discount in Odoo 17 POS
How to Manage Global Discount in Odoo 17 POS
 
Plant propagation: Sexual and Asexual propapagation.pptx
Plant propagation: Sexual and Asexual propapagation.pptxPlant propagation: Sexual and Asexual propapagation.pptx
Plant propagation: Sexual and Asexual propapagation.pptx
 
Key note speaker Neum_Admir Softic_ENG.pdf
Key note speaker Neum_Admir Softic_ENG.pdfKey note speaker Neum_Admir Softic_ENG.pdf
Key note speaker Neum_Admir Softic_ENG.pdf
 
Jamworks pilot and AI at Jisc (20/03/2024)
Jamworks pilot and AI at Jisc (20/03/2024)Jamworks pilot and AI at Jisc (20/03/2024)
Jamworks pilot and AI at Jisc (20/03/2024)
 
Basic Civil Engineering first year Notes- Chapter 4 Building.pptx
Basic Civil Engineering first year Notes- Chapter 4 Building.pptxBasic Civil Engineering first year Notes- Chapter 4 Building.pptx
Basic Civil Engineering first year Notes- Chapter 4 Building.pptx
 
Exploring_the_Narrative_Style_of_Amitav_Ghoshs_Gun_Island.pptx
Exploring_the_Narrative_Style_of_Amitav_Ghoshs_Gun_Island.pptxExploring_the_Narrative_Style_of_Amitav_Ghoshs_Gun_Island.pptx
Exploring_the_Narrative_Style_of_Amitav_Ghoshs_Gun_Island.pptx
 

Lab Tech Guy on HPLC wash solvents

  • 2. ©2009 Mourne Training Services Dear Lab Tech Guy, I am working in QC, doing mainly HPLC analysis. I am often confused by the composition of seal wash and needle wash. Do you have any advice on what is the right composition of both that increase efficiency of HPLC? Yours, Virender (Bangalore, India) ?
  • 3. ©2009 Mourne Training Services Dear Virender, To answer your question I will briefly describe the purpose of both seal wash and needle wash. The most suitable composition for each follows logically from their purpose. Seal wash is used to rinse the backs of the piston seals in the pump of a HPLC system. The piston is the part of the pump which moves back and forward in the pump head drawing in and pushing out the mobile phase solvent with each movement. Because it is a moving part, a seal around this piston is required to prevent the liquid leaking out the back of the pump. Piston Seal
  • 4. ©2009 Mourne Training Services Over a period of time small amounts of mobile phase solvents seep through the seal to the back of the pump head. If these solvents contain buffers then the salts may precipitate out forming deposits which can shorten the life of the seal. Seal wash is used when the mobile phase contains buffers. The wash flushes the back of the piston seals removing any deposits and maximising the lifetime of the seal. Seal Wash? It follows that the composition of the seal wash should be aqueous to dissolve buffers. A small amount of organic solvent is added to prevent bacteria growth and also to reduce the surface tension of the water (this helps the wash solvent cling to surfaces). Typical seal wash composition is 90% water and 10% organic solvent. The organic solvent may be methanol, acetonitrile or isopropyl alcohol (IPA).
  • 5. The needle in the HPLC system is used to introduce the sample into the mobile phase so that it can be separated on the HPLC column. The needle wash is used to clean the needle after an injection. The design of the needle in the injector system varies for different manufacturers. In some designs the inside of the needle is part of the flow path of the mobile phase and thus it is flushed continuously by the mobile phase between injections. In this case it is the outside of the needle which is cleaned by the needle wash. In other designs the needle is separate from the mobile phase flow path and thus the needle wash is used to clean the inside and outside of the needle. In all cases the composition of the needle wash needs to be matched to the sample since this is what you want to clean off the needle. Therefore the selection of a suitable needle wash is part of the development of a particular HPLC method. Typically a composition of needle wash which matches the proportions of aqueous and organic solvents in the mobile phase will be appropriate (assuming you are using reversed phase HPLC). ©2009 Mourne Training Services
  • 6. If the needle is not cleaned correctly then you may experience carryover between injections where sample from the previous injection which has not been cleaned from the needle will interfere with the next injection. Needle wash procedures will also help to prolong the life of the seals in the injection system. Appropriate selection of seal wash and needle wash solvents will help you in the quest for trouble free operation of your HPLC system and ensure that your analysis is not a washout.   Yours chromatographically, ©2009 Mourne Training Services You’ve run the analysis, now eat the snack (?)
  • 7. Brought to you by... www.mournetrainingservices.co.uk ©2009 Mourne Training Services