SlideShare una empresa de Scribd logo
1 de 18
GMR Institute of Technology
An Autonomous Institute Affiliated to JNTUK Kakinada.
Full semester Internship 1st Presentation
Dept. Of Electrical and Electronics Engineering
DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork
Learning Social Responsibility Respect for IndividualDeliver The Promise
GMRInstituteofTechnology,Rajam
7 August 2019
Title
FULL SEMESTER INTERNSHIP TRAINING
AT
GMR KAMALANGA ENERGY LIMITED
Topic:
HT and LT SWITCHGEAR
PREPARED BY:
G Ravindra Kumar
(14341A0233)
Under the esteemed guidance of
Debasis Das and Somanath Patra
2
DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork
Learning Social Responsibility Respect for IndividualDeliver The Promise
GMRInstituteofTechnology,Rajam
7 August 2019
Switchgear:
It is defined as the apparatus used for Switching, Controlling and Protecting the
Electrical Circuits and equipment.
In general, Switchgear is used for two purposes
• Switching during normal operating conditions for the purpose of Operation
and Maintenance.
• Switching during Faults and Abnormal conditions and interrupting the fault
currents.
3
DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork
Learning Social Responsibility Respect for IndividualDeliver The Promise
GMRInstituteofTechnology,Rajam
47 August 2019
Depending on the voltage level, switch gear is classified into 3 types
 Low Voltage Switchgear/LT Switchgear (<1KV)
 Medium Voltage Switchgear/MV Switchgear (<33KV)
 High Voltage Switchgear/HT Switchgear(>33KV)
But in heavily polluted areas Indoor Switchgear are preferred even for high
voltages
Scheme of switchgear bus
a) 2 incomers & 1 bus coupler
b) Bus coupler can be manual or auto changeover
DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork
Learning Social Responsibility Respect for IndividualDeliver The Promise
GMRInstituteofTechnology,Rajam
57 August 2019
Components of Switchgear:
 Circuit Breaker
 Relay
 Current Transformer
 Capacitor Voltage Transformer
 Terminal Box
 Switches
 Fuse
 Energy Meter
DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork
Learning Social Responsibility Respect for IndividualDeliver The Promise
GMRInstituteofTechnology,Rajam
67 August 2019
WHAT IS A CIRCUIT BREAKER?
A circuit breaker is an equipment that make or breaks a circuit either manually or
automatically under all conditions at no load, full load or short circuit.
Operating Principle
Two contacts called electrode remains closed under normal operating conditions.
When fault occurs on any part of the system, the trip coil of the circuit breaker
get energized and contacts are separated
The Circuit breaker used are:
 Air Circuit Breaker
 Vacuum Circuit Breaker
 Moulded Case Circuit Breaker
DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork
Learning Social Responsibility Respect for IndividualDeliver The Promise
GMRInstituteofTechnology,Rajam
77 August 2019
Vacuum Circuit Breaker
Advantages
• Compact, reliable and have
longer life.
• No fire hazards.
• No generation of gas during
and after operation.
• Can interrupt any fault current.
• No noise is produced while
operating.
• Require less power for control
operation.
DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork
Learning Social Responsibility Respect for IndividualDeliver The Promise
GMRInstituteofTechnology,Rajam
87 August 2019
Vacuum Circuit Breaker
Vacuum ChamberInside the Vacuum Circuit Breaker
DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork
Learning Social Responsibility Respect for IndividualDeliver The Promise
GMRInstituteofTechnology,Rajam
97 August 2019
Air Circuit Breaker
• Circuit breaker shall be three pole, single
throw, air break type.
• Circuit breakers shall be draw out type,
having SERVICE, TEST & ISOLATED
positions with indication for each
position.
• Each breaker shall be provided with an
emergency manual trip, mechanical ON-
OFF indicator mechanism,
charge/discharge indicator.
• Mechanical safety interlock shall be
provided to prevent the circuit breaker
from being racked in or out of the service
position when the breaker is closed.
DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork
Learning Social Responsibility Respect for IndividualDeliver The Promise
GMRInstituteofTechnology,Rajam
107 August 2019
220V to 24 V
converter for
Protection Device
Spring Charging
Handle
Plug Connector
for Aux
Contacts(Fixed &
Moveable)
Protection relay
with Lock out
release
Mechanical On
Off Button
CB Position
Indicator
CB Isolation
locking & Tagging
Spring Charge
Position Indication
CB Rack In & Out
Handle
CB Name Plate
Ratting
CB Open/Close
Indication
Air Circuit Breaker
DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork
Learning Social Responsibility Respect for IndividualDeliver The Promise
GMRInstituteofTechnology,Rajam
117 August 2019
Molded Case Circuit Breaker:
 Molded case circuit breakers (MCCBs) can withstand amperage levels of up
to 2,500 amperes.
 It’s also used for overload and fault protection, though normally for more
energy-intensive systems.
 The adjustability of MCCBs make them particularly useful in main electric
feeders as more circuits may eventually be added to the system and thus, will
possibly require a change in the overall trip settings.
 Motor protection is also a common application for MCCBs.
DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork
Learning Social Responsibility Respect for IndividualDeliver The Promise
GMRInstituteofTechnology,Rajam
127 August 2019
• Definition:- Relay is a device which detects an abnormal fault
condition by constantly measuring the electrical quantities which are
different under normal and faulty conditions.
Battery
Circuit
Breaker
C.T. Relay
Coil
Trip Coil
Relay operating
circuit
Tripping circuit
Sensing circuit
Relay
DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork
Learning Social Responsibility Respect for IndividualDeliver The Promise
GMRInstituteofTechnology,Rajam
137 August 2019
Protection Relays
Numerical Relays
Feeder Protection
Transformer
Protection
Voltage
Management
Motor Protection
Electromechanical
Relays
CB Fuse failure
indication relay
CB contact
multiplier
Relay Classification
DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork
Learning Social Responsibility Respect for IndividualDeliver The Promise
GMRInstituteofTechnology,Rajam
147 August 2019
Current Transformers
Current Transformers are used as measuring and protecting equipment, that
step down the high current to low measurable current.
Wound Type Ring Type Window/Bar
Type
Core Balance Current Transformer is a ring type current transformer, in which
three core cable or three single core cables of three phase system passes. This
transformer is normally used for earth fault protection for low and medium
voltage system.
DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork
Learning Social Responsibility Respect for IndividualDeliver The Promise
GMRInstituteofTechnology,Rajam
157 August 2019
SWITCHES
The switches shall be TP/TPN heavy duty, air break mechanism operated by a
suitable external handle with position indicator.
FUSES
 The fuses shall be of HRC link type. Visual indication shall be provided to
indicate fuse failure.
 The motor fuse rating and characteristics shall be suitably chosen so that they
do not operate during the starting period of the motor.
DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork
Learning Social Responsibility Respect for IndividualDeliver The Promise
GMRInstituteofTechnology,Rajam
167 August 2019
Detail Load upon Individual Unit 6.6 KV Switchgear
UAT-A
1 WORKING INCOMER OF 6.6KV UNIT SECTION 1A
2 STAND 3BY INCOMER (TIE TO ST-A)
3 BUSBAR PT
4 VENTILATION TRANSFORMER
5 U-1 LV TRANSFORMER 1A
6 U-1 ESP TRANSFORMER 1A
7 IDCT TRANSFORMER 1A
8 ID FAN 1A
9 PA FAN 1A
10 CW PUMP 1A
11 CONDENSATE PUMP 1A
12 FD FAN 1A
13 UAT-1A SPARE-1
14 TDBFBP 1A
15 MILL 1A
16 MILL 1B
17 MILL 1 C
18 Bucket Wheel Stacker 1 And Reclaimer 1A
UAT-B
1 WORKING INCOMER OF 6.6KV USECTION 1B
2 STAND 1BY INCOMER (TIE TO ST-B)
3 BUSBAR PT
4 U-1 LV TRANSFORMER 1B
5 U-1 ESP TRANSFORMER 1B
6 IDCT TRANSFORMER 1B
7 ID FAN 1B
8 PA FAN 1B
9 CW PUMP 1B
10 CONDENSATE PUMP 1B
11 FD FAN 1B
12 6.6 kV Intake Pump House 1A
13 LIGHTING TRANSFORMER
14 TDBFBP 1B
15 MILL 1 D
16 MILL 1E
17 MILL 1F
18 UAT-1B SPARE-2
DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork
Learning Social Responsibility Respect for IndividualDeliver The Promise
GMRInstituteofTechnology,Rajam
177 August 2019
SNO. Description Rating
415 V UNIT Aux.Section in MPB(LOC: 6.3 M TG building)
PCC#A (2500KVA dry type transformer 6.6 KV/0.433 KV)
1 Emergency MCC power#A
2 Sealing air Fan#A 185 Kw
3 Vacuum pump#A 110 Kw
4 UPS #1 power supply 240 KVA
5 Condensate water Transportation pump#A 90 KW
6 BA slurry pump#A 110 Kw
7 Turbine MCC#A 255KW
8 Boiler MCC#A 329KW
9 Chemical MCC#A 52Kw
10 Boiler Motor Drive valve power supply panel 70Kw
11 In-line pump#A 75 Kw
12 Power for lighting & maintenance of switch cabinet#A 20 Kw
13 Switch cabinet Power#A 10Kw
DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork
Learning Social Responsibility Respect for IndividualDeliver The Promise
GMRInstituteofTechnology,Rajam
187 August 2019

Más contenido relacionado

La actualidad más candente

La actualidad más candente (20)

SWITCHGEAR
SWITCHGEARSWITCHGEAR
SWITCHGEAR
 
Protection and Switchgear
Protection and SwitchgearProtection and Switchgear
Protection and Switchgear
 
Protection & switchgear
Protection & switchgear   Protection & switchgear
Protection & switchgear
 
Switchgear - complete guide
Switchgear - complete guideSwitchgear - complete guide
Switchgear - complete guide
 
Series & shunt compensation and FACTs Devices
Series & shunt compensation and FACTs DevicesSeries & shunt compensation and FACTs Devices
Series & shunt compensation and FACTs Devices
 
Ppt on protection of power transformers
Ppt on protection of power transformersPpt on protection of power transformers
Ppt on protection of power transformers
 
Switchgear presentation
Switchgear presentationSwitchgear presentation
Switchgear presentation
 
Power system protection topic 1
Power system protection topic 1Power system protection topic 1
Power system protection topic 1
 
Introduction to mv switchgear
Introduction to mv switchgearIntroduction to mv switchgear
Introduction to mv switchgear
 
Switchgear presentation
Switchgear presentationSwitchgear presentation
Switchgear presentation
 
Transformer protection
Transformer protectionTransformer protection
Transformer protection
 
HV testing of insulator
HV testing of insulatorHV testing of insulator
HV testing of insulator
 
Power factor
Power factorPower factor
Power factor
 
Factors to be considered while selecting CT
Factors to be considered while selecting CTFactors to be considered while selecting CT
Factors to be considered while selecting CT
 
Unit 03 Protective relays
Unit  03 Protective relaysUnit  03 Protective relays
Unit 03 Protective relays
 
Transformer Parts and functions
Transformer Parts and functionsTransformer Parts and functions
Transformer Parts and functions
 
Dol and star delta
Dol and star deltaDol and star delta
Dol and star delta
 
Protective relay
Protective relay Protective relay
Protective relay
 
Power system protection
Power system protectionPower system protection
Power system protection
 
Structure of power system
Structure of power systemStructure of power system
Structure of power system
 

Similar a HT and LT SWITCHGEAR

Similar a HT and LT SWITCHGEAR (20)

IRJET- Battery Management System by using PWM Charge Controller
IRJET- Battery Management System by using PWM Charge ControllerIRJET- Battery Management System by using PWM Charge Controller
IRJET- Battery Management System by using PWM Charge Controller
 
C&S Electric Summer Training Report
C&S Electric Summer Training ReportC&S Electric Summer Training Report
C&S Electric Summer Training Report
 
C&S Electric Summer Training Report
C&S Electric Summer Training ReportC&S Electric Summer Training Report
C&S Electric Summer Training Report
 
Implementation of self excited induction generator
Implementation of self excited induction generatorImplementation of self excited induction generator
Implementation of self excited induction generator
 
Implementation of self excited induction generator (seig) with igbt based ele...
Implementation of self excited induction generator (seig) with igbt based ele...Implementation of self excited induction generator (seig) with igbt based ele...
Implementation of self excited induction generator (seig) with igbt based ele...
 
Multilevel inverter technology
Multilevel inverter technologyMultilevel inverter technology
Multilevel inverter technology
 
IRJET- Current Limiting Transformer
IRJET-  	  Current Limiting TransformerIRJET-  	  Current Limiting Transformer
IRJET- Current Limiting Transformer
 
Design and development of three phase Blower motor
Design and development of three phase Blower motorDesign and development of three phase Blower motor
Design and development of three phase Blower motor
 
Jm3417081729
Jm3417081729Jm3417081729
Jm3417081729
 
IRJET- Solar Operated Four-Way Hacksaw Machine
IRJET-  	  Solar Operated Four-Way Hacksaw MachineIRJET-  	  Solar Operated Four-Way Hacksaw Machine
IRJET- Solar Operated Four-Way Hacksaw Machine
 
IRJET- Performance Evaluation of Micro Grid
IRJET- Performance Evaluation of Micro GridIRJET- Performance Evaluation of Micro Grid
IRJET- Performance Evaluation of Micro Grid
 
IRJET- Review and Analyse of Ground Fault Circuit Interupter
IRJET- Review and Analyse of Ground Fault Circuit InterupterIRJET- Review and Analyse of Ground Fault Circuit Interupter
IRJET- Review and Analyse of Ground Fault Circuit Interupter
 
Detection of Power Grid Synchronization Failure on Sensing Frequency and Volt...
Detection of Power Grid Synchronization Failure on Sensing Frequency and Volt...Detection of Power Grid Synchronization Failure on Sensing Frequency and Volt...
Detection of Power Grid Synchronization Failure on Sensing Frequency and Volt...
 
IRJET- A Grid-Control Scheme Connected to a Wind Energy System for Improving ...
IRJET- A Grid-Control Scheme Connected to a Wind Energy System for Improving ...IRJET- A Grid-Control Scheme Connected to a Wind Energy System for Improving ...
IRJET- A Grid-Control Scheme Connected to a Wind Energy System for Improving ...
 
IRJET- Electricity Generation by Hybrid Solar and Wind
IRJET-  	  Electricity Generation by Hybrid Solar and WindIRJET-  	  Electricity Generation by Hybrid Solar and Wind
IRJET- Electricity Generation by Hybrid Solar and Wind
 
IRJET- Ergonomic Design and Development of Flywheel in Exercise Equipment for...
IRJET- Ergonomic Design and Development of Flywheel in Exercise Equipment for...IRJET- Ergonomic Design and Development of Flywheel in Exercise Equipment for...
IRJET- Ergonomic Design and Development of Flywheel in Exercise Equipment for...
 
induction motor protection system
induction motor protection systeminduction motor protection system
induction motor protection system
 
Research Internship Report
Research Internship ReportResearch Internship Report
Research Internship Report
 
40220140505005
4022014050500540220140505005
40220140505005
 
40220140505005
4022014050500540220140505005
40220140505005
 

Último

Call Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
Call Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort ServiceCall Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
Call Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
9953056974 Low Rate Call Girls In Saket, Delhi NCR
 
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
dollysharma2066
 
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Christo Ananth
 

Último (20)

ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdfONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
 
(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7
(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7
(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7
 
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
 
Double rodded leveling 1 pdf activity 01
Double rodded leveling 1 pdf activity 01Double rodded leveling 1 pdf activity 01
Double rodded leveling 1 pdf activity 01
 
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
 
UNIT-IFLUID PROPERTIES & FLOW CHARACTERISTICS
UNIT-IFLUID PROPERTIES & FLOW CHARACTERISTICSUNIT-IFLUID PROPERTIES & FLOW CHARACTERISTICS
UNIT-IFLUID PROPERTIES & FLOW CHARACTERISTICS
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptx
 
Call Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
Call Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort ServiceCall Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
Call Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
 
Thermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.pptThermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.ppt
 
University management System project report..pdf
University management System project report..pdfUniversity management System project report..pdf
University management System project report..pdf
 
UNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular ConduitsUNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular Conduits
 
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
 
UNIT-III FMM. DIMENSIONAL ANALYSIS
UNIT-III FMM.        DIMENSIONAL ANALYSISUNIT-III FMM.        DIMENSIONAL ANALYSIS
UNIT-III FMM. DIMENSIONAL ANALYSIS
 
data_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdfdata_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdf
 
Thermal Engineering Unit - I & II . ppt
Thermal Engineering  Unit - I & II . pptThermal Engineering  Unit - I & II . ppt
Thermal Engineering Unit - I & II . ppt
 
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
 
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptxBSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
 
Glass Ceramics: Processing and Properties
Glass Ceramics: Processing and PropertiesGlass Ceramics: Processing and Properties
Glass Ceramics: Processing and Properties
 
Unit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdfUnit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdf
 
NFPA 5000 2024 standard .
NFPA 5000 2024 standard                                  .NFPA 5000 2024 standard                                  .
NFPA 5000 2024 standard .
 

HT and LT SWITCHGEAR

  • 1. GMR Institute of Technology An Autonomous Institute Affiliated to JNTUK Kakinada. Full semester Internship 1st Presentation Dept. Of Electrical and Electronics Engineering
  • 2. DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork Learning Social Responsibility Respect for IndividualDeliver The Promise GMRInstituteofTechnology,Rajam 7 August 2019 Title FULL SEMESTER INTERNSHIP TRAINING AT GMR KAMALANGA ENERGY LIMITED Topic: HT and LT SWITCHGEAR PREPARED BY: G Ravindra Kumar (14341A0233) Under the esteemed guidance of Debasis Das and Somanath Patra 2
  • 3. DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork Learning Social Responsibility Respect for IndividualDeliver The Promise GMRInstituteofTechnology,Rajam 7 August 2019 Switchgear: It is defined as the apparatus used for Switching, Controlling and Protecting the Electrical Circuits and equipment. In general, Switchgear is used for two purposes • Switching during normal operating conditions for the purpose of Operation and Maintenance. • Switching during Faults and Abnormal conditions and interrupting the fault currents. 3
  • 4. DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork Learning Social Responsibility Respect for IndividualDeliver The Promise GMRInstituteofTechnology,Rajam 47 August 2019 Depending on the voltage level, switch gear is classified into 3 types  Low Voltage Switchgear/LT Switchgear (<1KV)  Medium Voltage Switchgear/MV Switchgear (<33KV)  High Voltage Switchgear/HT Switchgear(>33KV) But in heavily polluted areas Indoor Switchgear are preferred even for high voltages Scheme of switchgear bus a) 2 incomers & 1 bus coupler b) Bus coupler can be manual or auto changeover
  • 5. DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork Learning Social Responsibility Respect for IndividualDeliver The Promise GMRInstituteofTechnology,Rajam 57 August 2019 Components of Switchgear:  Circuit Breaker  Relay  Current Transformer  Capacitor Voltage Transformer  Terminal Box  Switches  Fuse  Energy Meter
  • 6. DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork Learning Social Responsibility Respect for IndividualDeliver The Promise GMRInstituteofTechnology,Rajam 67 August 2019 WHAT IS A CIRCUIT BREAKER? A circuit breaker is an equipment that make or breaks a circuit either manually or automatically under all conditions at no load, full load or short circuit. Operating Principle Two contacts called electrode remains closed under normal operating conditions. When fault occurs on any part of the system, the trip coil of the circuit breaker get energized and contacts are separated The Circuit breaker used are:  Air Circuit Breaker  Vacuum Circuit Breaker  Moulded Case Circuit Breaker
  • 7. DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork Learning Social Responsibility Respect for IndividualDeliver The Promise GMRInstituteofTechnology,Rajam 77 August 2019 Vacuum Circuit Breaker Advantages • Compact, reliable and have longer life. • No fire hazards. • No generation of gas during and after operation. • Can interrupt any fault current. • No noise is produced while operating. • Require less power for control operation.
  • 8. DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork Learning Social Responsibility Respect for IndividualDeliver The Promise GMRInstituteofTechnology,Rajam 87 August 2019 Vacuum Circuit Breaker Vacuum ChamberInside the Vacuum Circuit Breaker
  • 9. DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork Learning Social Responsibility Respect for IndividualDeliver The Promise GMRInstituteofTechnology,Rajam 97 August 2019 Air Circuit Breaker • Circuit breaker shall be three pole, single throw, air break type. • Circuit breakers shall be draw out type, having SERVICE, TEST & ISOLATED positions with indication for each position. • Each breaker shall be provided with an emergency manual trip, mechanical ON- OFF indicator mechanism, charge/discharge indicator. • Mechanical safety interlock shall be provided to prevent the circuit breaker from being racked in or out of the service position when the breaker is closed.
  • 10. DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork Learning Social Responsibility Respect for IndividualDeliver The Promise GMRInstituteofTechnology,Rajam 107 August 2019 220V to 24 V converter for Protection Device Spring Charging Handle Plug Connector for Aux Contacts(Fixed & Moveable) Protection relay with Lock out release Mechanical On Off Button CB Position Indicator CB Isolation locking & Tagging Spring Charge Position Indication CB Rack In & Out Handle CB Name Plate Ratting CB Open/Close Indication Air Circuit Breaker
  • 11. DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork Learning Social Responsibility Respect for IndividualDeliver The Promise GMRInstituteofTechnology,Rajam 117 August 2019 Molded Case Circuit Breaker:  Molded case circuit breakers (MCCBs) can withstand amperage levels of up to 2,500 amperes.  It’s also used for overload and fault protection, though normally for more energy-intensive systems.  The adjustability of MCCBs make them particularly useful in main electric feeders as more circuits may eventually be added to the system and thus, will possibly require a change in the overall trip settings.  Motor protection is also a common application for MCCBs.
  • 12. DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork Learning Social Responsibility Respect for IndividualDeliver The Promise GMRInstituteofTechnology,Rajam 127 August 2019 • Definition:- Relay is a device which detects an abnormal fault condition by constantly measuring the electrical quantities which are different under normal and faulty conditions. Battery Circuit Breaker C.T. Relay Coil Trip Coil Relay operating circuit Tripping circuit Sensing circuit Relay
  • 13. DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork Learning Social Responsibility Respect for IndividualDeliver The Promise GMRInstituteofTechnology,Rajam 137 August 2019 Protection Relays Numerical Relays Feeder Protection Transformer Protection Voltage Management Motor Protection Electromechanical Relays CB Fuse failure indication relay CB contact multiplier Relay Classification
  • 14. DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork Learning Social Responsibility Respect for IndividualDeliver The Promise GMRInstituteofTechnology,Rajam 147 August 2019 Current Transformers Current Transformers are used as measuring and protecting equipment, that step down the high current to low measurable current. Wound Type Ring Type Window/Bar Type Core Balance Current Transformer is a ring type current transformer, in which three core cable or three single core cables of three phase system passes. This transformer is normally used for earth fault protection for low and medium voltage system.
  • 15. DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork Learning Social Responsibility Respect for IndividualDeliver The Promise GMRInstituteofTechnology,Rajam 157 August 2019 SWITCHES The switches shall be TP/TPN heavy duty, air break mechanism operated by a suitable external handle with position indicator. FUSES  The fuses shall be of HRC link type. Visual indication shall be provided to indicate fuse failure.  The motor fuse rating and characteristics shall be suitably chosen so that they do not operate during the starting period of the motor.
  • 16. DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork Learning Social Responsibility Respect for IndividualDeliver The Promise GMRInstituteofTechnology,Rajam 167 August 2019 Detail Load upon Individual Unit 6.6 KV Switchgear UAT-A 1 WORKING INCOMER OF 6.6KV UNIT SECTION 1A 2 STAND 3BY INCOMER (TIE TO ST-A) 3 BUSBAR PT 4 VENTILATION TRANSFORMER 5 U-1 LV TRANSFORMER 1A 6 U-1 ESP TRANSFORMER 1A 7 IDCT TRANSFORMER 1A 8 ID FAN 1A 9 PA FAN 1A 10 CW PUMP 1A 11 CONDENSATE PUMP 1A 12 FD FAN 1A 13 UAT-1A SPARE-1 14 TDBFBP 1A 15 MILL 1A 16 MILL 1B 17 MILL 1 C 18 Bucket Wheel Stacker 1 And Reclaimer 1A UAT-B 1 WORKING INCOMER OF 6.6KV USECTION 1B 2 STAND 1BY INCOMER (TIE TO ST-B) 3 BUSBAR PT 4 U-1 LV TRANSFORMER 1B 5 U-1 ESP TRANSFORMER 1B 6 IDCT TRANSFORMER 1B 7 ID FAN 1B 8 PA FAN 1B 9 CW PUMP 1B 10 CONDENSATE PUMP 1B 11 FD FAN 1B 12 6.6 kV Intake Pump House 1A 13 LIGHTING TRANSFORMER 14 TDBFBP 1B 15 MILL 1 D 16 MILL 1E 17 MILL 1F 18 UAT-1B SPARE-2
  • 17. DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork Learning Social Responsibility Respect for IndividualDeliver The Promise GMRInstituteofTechnology,Rajam 177 August 2019 SNO. Description Rating 415 V UNIT Aux.Section in MPB(LOC: 6.3 M TG building) PCC#A (2500KVA dry type transformer 6.6 KV/0.433 KV) 1 Emergency MCC power#A 2 Sealing air Fan#A 185 Kw 3 Vacuum pump#A 110 Kw 4 UPS #1 power supply 240 KVA 5 Condensate water Transportation pump#A 90 KW 6 BA slurry pump#A 110 Kw 7 Turbine MCC#A 255KW 8 Boiler MCC#A 329KW 9 Chemical MCC#A 52Kw 10 Boiler Motor Drive valve power supply panel 70Kw 11 In-line pump#A 75 Kw 12 Power for lighting & maintenance of switch cabinet#A 20 Kw 13 Switch cabinet Power#A 10Kw
  • 18. DepartmentofMechanicalEngineering Humility Entrepreneurship Teamwork Learning Social Responsibility Respect for IndividualDeliver The Promise GMRInstituteofTechnology,Rajam 187 August 2019